key: cord-0741618-3xlg9az0 authors: Ross, Georgina M.S.; Filippini, Daniel; Nielen, Michel W.F.; Salentijn, Gert IJ. title: Interconnectable solid-liquid protein extraction unit and chip-based dilution for multiplexed consumer immunodiagnostics date: 2020-10-16 journal: Anal Chim Acta DOI: 10.1016/j.aca.2020.10.018 sha: ffea4b1b52a7d126ceceb64571992a3357e49a6b doc_id: 741618 cord_uid: 3xlg9az0 While consumer-focused food analysis is upcoming, the need for multiple sample preparation and handling steps is limiting. On-site and consumer-friendly analysis paradoxically still requires laboratory-based and skill-intensive sample preparation methods. Here, we present a compact, inexpensive, and novel prototype immunosensor combining sample preparation and on-chip reagent storage for multiplex allergen lateral flow immunosensing. Our comprehensive approach paves the way for personalized consumer diagnostics. The prototype allows for handheld solid-liquid extraction, pipette-free on-chip dilution, and adjustment of sample concentrations into the appropriate assay dynamic working range. The disposable and interconnectable homogenizer unit allows for the extraction and 3D-sieve based filtration of allergenic proteins from solid bakery products in 1 minute. The homogenizer interconnects with a 3D-printed unibody lab-on-a-chip (ULOC) microdevice, which is used to deliver precise volumes of sample extract to a reagent reservoir. The reagent reservoir is implemented for on-chip storage of carbon nanoparticle labeled antibodies and running buffer for dilution. The handheld prototype allows for total homogenization of solid samples, solid-liquid protein extraction, 3D-printed sieve based filtration, ULOC-enabled dilution, mixing, transport, and smartphone-based detection of hazelnut and peanut allergens in solid bakery products with limited operational complexity. The multiplex lateral flow immunoassay (LFIA) detects allergens as low as 0.1 ppm in real bakery products, and the system is already consumer-operable, demonstrating its potential for future citizen science approaches. The designed system is suitable for a wide range of analytical applications outside of food safety, provided an LFIA is available. have previously been developed, characterized, and validated [13, 27] . Running buffer (RB)/extraction albumin (BSA; Sigma-Aldrich, Zwijndrecht, The Netherlands) and 0.05% tween-20 (v/v) (Merck, Darmstadt; Germany). The 10 mL and 1 mL disposable plastic syringes that were used for the 86 homogenizer and air displacement syringes were purchased from Becton-Dickinson (Utrecht, The 87 Netherlands), and low binding syringe filters used to filter total protein extracts (5 µm; 1.2 µm; 0.45 88 µm) were acquired from Pall Life Sciences (Pall Netherlands B.V., Medemblik; The Netherlands). Silicon tubing for ULOC connectors was purchased from Esska-Tech (Arvika; Sweden). ULOCs were Standardized certified reference materials for food allergens are not currently available; therefore, 98 total hazelnut protein (THP), total peanut protein (TPP), and blank cookie (BC) extracts were 99 prepared in-house [13, 27] . See Supplementary Information (SI) Table S1 for ingredient lists and Figure S1 ), device holder (SI Figure S2) , and interchangeable LFIA cartridges (SI Figure S3 ). The handheld and interconnectable homogenizer unit enables total homogenization and solid-liquid 122 protein extraction from solid food samples. 3D-printed sieves with approximate pore sizes of 0.5 mm 123 were cut by laser (HL40-5g, Full Spectrum Laser LLC, Las Vegas, NV; USA) into discs (18 mm 124 diameter; SI Figure S1 ). Two sieves ( Figure 1A ) insert into a 10 mL syringe at an offset to each other. As the plunger pushes solid material against the first 3D-printed sieve, it breaks into smaller pieces 126 which are subsequently blocked by the second sieve that is kept at an offset, preventing particles 127 from blocking microchannels in the ULOC. Silicon tubing (1.5 mm inner diameter, 40 mm length) 128 connects with the ULOC unibody connector. The tubing can be used as a finger pump or is connected 129 by a second larger piece of silicon tubing (2.5 inner diameter, 20 mm length) to the syringe tip. The remaining two unibody connectors were joined together by silicon tubing (see Figure 1B ). The ULOC could be inserted into an opening (50 mm W x 35 mm L) in the 3D-printed device holder, 147 which shielded the assay from ambient light (see SI; Figure S2 ). The LFIA cartridge, which fits 2 148 LFIAs (4 or 5 mm wide), ensured that the appropriate LFIAs were aligned with the test and reference Images and videos were acquired by smartphone, attached to the holder frame, using OpenCamera 179 to ensure fixed acquisition conditions (fixed focus, locked exposure, controlled illumination, for videos: 180 30 frames per second (fps), 720 x 480 pixels). LFIA results appeared on the screen as they emerged. Subsequently, videos were split into images of 1 fps using Adapter (v2.1.6), and the resulting time 182 point images were analyzed offline in ImageJ by splitting the images into their color channels. A blue 183 channel pixel intensity (BCPI) reading was taken from below the test line at t=0 as a background 184 response; the BCPI measurements from the test and control lines were then subtracted from this to 185 give the corrected BCPI (cBCPI) value. In the assay dynamic working range, cBCPI increases as test Experiments were performed in triplicate; see Figure 3 for the pictogram operation procedure and SI Video 1 for a short demo of the total system operation from extraction to LFIA readout. Before sealing 195 the ULOC with adhesive tape, the reagent reservoir was filled with 2 µL CNP-mAb and 190 µL RB, particles, and analyzed their size distribution using ImageJ (see SI Protocol S1 for full details). For sample types C and D (approximately 0.25 g), and then incubated with 1 mL RB for 1 minute, 204 before filtering through the 3D-sieves. Finally, to characterize the system for detecting real-life 205 incurred and processed allergens, sample type D was investigated. The volume of the pre-loaded 206 CNP-mAb was increased to 4 µL (2 µL for the anti-hazelnut mAb-CNP and 2 µL for the anti-peanut A major restriction of allergen analysis is the lengthy extraction process, which typically includes 224 weighing, heating, grinding, and numerous filtering steps [2, 11] . As such, extended extractions delay 225 rapid screening tests such as LFIA. While a 2 minute magneto-assisted allergen antigen extraction 226 has been reported, this still required off-chip microwave pre-heating [3]. Previously we [13] described 227 a method for extracting total proteins from cookies and peanut flour at room temperature (RT) in 30 228 minutes. This method is promising because even with the shorter extraction time and at RT, the indicating a much shorter extraction time could still be appropriate for extracting relevant allergenic proteins without delaying the analysis. To test this, we evaluated different extraction times to attempt Allergenic proteins exist in foods over a broad dynamic range and must be detected at trace levels for 255 protecting sensitive individuals. Still, it is vital to understand that highly concentrated samples can 256 yield paradoxically low signal intensities, which could easily be misinterpreted by a consumer. However, it is reported that sample dilution (DF x 10-100) can minimize the occurrence of false-258 negatives [11] [12] [13] . While sample dilution is a prerequisite for allergen analysis, we cannot expect the extracted sample is injected into the reservoir, it efficiently mixes with the pre-stored CNP-mAbs by air 262 displacement and is also diluted in RB by an adjustable DF. Figure 5A compares the BCPIs for on-chip (ULOC-enabled) versus off-chip (manually pipetted) 265 dilutions (dye in water, sample type A, n=3) using different DFs. Figure 5B indicates where to take the 266 pre-dilution (DF x 0), the mid-dilution (5C), and the on-chip and off-chip (5D) BCPIs measurements. For consistency, the measurements were always taken below the dye's meniscus. The ULOC DFs 268 invariably matched the manually pipetted DFs, suggesting that the ULOC delivers well-defined 269 sample volumes (see SI Figure S5 ). ULOC devices for other applications have already been To investigate the influence of assay duration on the signal development, the LFIAs were readout Allergenic proteins can be subject to conformational alterations during food processing [29] . Therefore, biosensors must demonstrate proficiency in detecting allergens in both raw and processed 300 products. Here, solid cookie samples were pre-weighed (0.25 g) for consistency. Still, in real life, the user can instead fill the homogenizer with the cookie to the 1 mL mark to approximately obtain the 302 same sample weight (see SI Figure S7 ). Though this method is less precise, it would suffice for 303 qualitative assessment of bakery products for the presence of allergens. Previously, we found that For sample B (THP extract spiked into BC extract (v/v); Figure 6B ), the T/C ratio detection limit is 1 Thermal processing, such as baking, can affect allergen detectability [29] . See Figure 6 to compare 324 signal development for samples using total allergen protein extracts (6E) with samples containing 325 incurred allergens (6D&F). Testing commercial hazelnut cookies mixed with blank cookies (sample 326 type D1) exemplifies the effectiveness of extracting incurred proteins from a solid matrix into a 327 testable liquid and detecting the allergenic proteins in this liquid. Sample D1 has a LOD of 0.1 ppm 328 (n=3, RSD ± 3.03%; see Figure 6D and F) for processed hazelnut. Compellingly, the D1 LOD is lower 329 than the LOD for sample C. The LFIA is more sensitive towards processed hazelnut. This sensitivity 330 has also been indicated in our singleplex hazelnut LFIA where the same mAb reached the same LOD In Figure 6 , high-concentration effects (1000 and 100 ppm) are evident. Even with the faster 340 extraction time and ULOC-dilution concentration-dependent effects still occur, affirming the necessity 341 to dilute allergen samples before analysis [11, 12] . For consumer testing, the loss of the control line 342 (at 1000 ppm) could be problematic, and some tests have additional target lines to limit this [1]. Here, slightly lower deviation in multiplex measurements owing to increased control line stability, from using 353 two different CNP-mAbs compared with singleplex analysis. The sensitivity is even better than when [30] ECSA, Ten principles of citizen science European Citizen Science Association https://ecsa.citizen-science.net/, 2020. DNA diagnostics of malaria in low resource underserved rural communities 3D-Printed Paper Spray Ionization Cartridge with Fast Wetting Rapid Antibody Selection Using Surface Plasmon Resonance for High-Speed and Sensitive Hazelnut Lateral Flow Prototypes NIH Image to ImageJ: 25 years of image analysis Effect of processing on conformational changes of food proteins related to G.M.S Ross: Conceptualization; Methodology; Validation Investigation; Data Curation; Writing Original Draft; Writing -Review & Editing Writing -Review & Editing; Supervision; Funding Acquisition Visualization; Supervision J o u r n a l P r e -p r o o f ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.☐The authors declare the following financial interests/personal relationships which may be considered as potential competing interests:J o u r n a l P r e -p r o o f