key: cord-0740753-uytlm4qs authors: Marggrander, Daniel T.; Borgans, Frauke; Jacobi, Volkmar; Neb, Holger; Wolf, Timo title: Lung Ultrasound Findings in Patients with COVID-19 date: 2020-10-01 journal: SN Compr Clin Med DOI: 10.1007/s42399-020-00553-0 sha: 9139b084c76964e482b7e5414ec0d901f8c82f6e doc_id: 740753 cord_uid: uytlm4qs The current SARS-CoV-2 outbreak leads to a growing need of point-of-care thoracic imaging that is compatible with isolation settings and infection prevention precautions. We retrospectively reviewed 17 COVID-19 patients who received point-of-care lung ultrasound imaging in our isolation unit. Lung ultrasound was able to detect interstitial lung disease effectively; severe cases showed bilaterally distributed B-Lines with or without consolidations; one case showed bilateral pleural plaques. Corresponding to CT scans, interstitial involvement is accurately depicted as B-Lines on lung ultrasound. Lung ultrasound might be suitable for detecting interstitial involvement in a bedside setting under high security isolation precautions. Introduction SARS-CoV-2 is a coronavirus that emerged in December 2019 in Wuhan city, Province Hubei, China [1] that causes COVID-19, a viral disease that causes influenza-like illness, which can progress into pneumonia [2] . The evaluation of the extent of pulmonary involvement using radiographic imaging is problematic due to infection prevention and control (IPC) measures that must be taken and the sheer number of cases that need evaluation. Critically ill patients, especially those treated with mechanical ventilation and extracorporal circulation devices, are particularly difficult to transport in order to obtain computed tomography (CT-) scans, and bedside chest x-ray (CXR) remains an unreliably inaccurate and unsatisfactory imaging modality [3, 4] . Point-of-care ultrasound imaging however is available at the patients' bedside and accelerates diagnostics in respiratory distress in comparison to radiographic imaging [5] . Reproducible imaging artifacts in lung ultrasound correspond to underlying conditions of pulmonary tissue. The healthy lung surface yields the sonographic image of pleural gliding as well so-called A-Lines, horizontal reverberations of the pleural line. Thickened interlobular septa, for instance in edema, fibrosis, or infectious disease [6] , cause B-Lines on LUS [7] . Those are comet tailartifacts, vertical lines arising from the pleural line, extending to the bottom of the screen and moving with respiration. Three or more B-Lines per intercostal space are considered pathological, less than three (indicated by a lowercase "b" [8] ) may occur in healthy individuals without corresponding to pathology. A tissue-like pattern is observed on ultrasound in the absence of air, with irregular borders adjacent to aerated lung, the so-called shred sign, occurring for instance in pneumonic consolidation, atelectasis, pulmonary embolism (PE) or solid tumors. Dynamic detection of air within the bronchi or perfusion detected by color Doppler may help differentiate these signs further [4] . In intensive care, lung ultrasound (LUS) can be used as bedside imaging without disadvantageous effects on patient care while reducing chest radiography and CTscans [9] [10] [11] . LUS is useful in detecting interstitial pulmonary pathology [4] including interstitial pneumonia, which is the most common finding in patients with SARS-CoV-2 infection Daniel T. Marggrander and Frauke Borgans contributed equally to this work. This article is part of the Topical Collection on Covid-19 and pulmonary involvement [12] . A recently published letter describes the use of LUS and the typical ultrasonographic appearance in COVID-19 patients in Xiangya, Hunan, and in Beijing [13] . Due to the recent emergence of the disease and ongoing disease burden worldwide, we decided to share our experience with point-of-care bedside LUS in patients with COVID-19 in our department and provide a comparison of common LUS imaging and their corresponding findings on chest CT, as well as unusual LUS findings in COVID-19. We retrospectively reviewed LUS examinations that we performed in our isolation unit in patients who tested positive in polymerase chain reaction (PCR) of oral and nasal swabs for SARS-CoV-2. All patients received thorough scanning of their anterior, lateral, and posterior chest wall using either an APLIO 300 TUS-A300 ultrasound system (Toshiba, Tokyo) with a 3.5 MHz convex probe or a NEMIO SSA-550a ultrasound system (Toshiba, Tokyo) with a 3.75 MHz convex probe. We assessed at least 4 intercostal spaces in both the anterior and lateral chest wall. In all but two patients, who were in critical condition and could not sit upright, we assessed at least 6 intercostal spaces in the posterior chest wall. In the supine patient, the probe was placed perpendicularly to the skin in each intercostal space, starting at the parasternal line, and moved laterally to obtain views of large portions of the lung surface. Posterior lung scans in the sitting patient started at the paravertebral line, moving laterally. All scans were strictly performed in longitudinal orientation (with the index of the probe facing towards the patients' head). We assessed the appearance of A-Lines, B-Lines, consolidations, and pleural abnormalities. Either TW (attending physician) or DM (doctoral candidate) performed LUS and discussed the obtained images with the other ultrasound examiner to reach a consensus. Both TW and DM have had 3 years of experience in LUS, focusing on LUS in pulmonary infections. If available, we reviewed corresponding conventional imaging that was performed in these patients for comparison. CXR was performed in posterior-anterior projection and lateral projection in stable patients, or in anterior-posterior projection as bedside radiograph in critically ill patients. Chest CT was performed without contrast agent for assessment of pulmonary SARS-CoV-2 involvement, or with contrast agent in critically ill patients where PE posed a probable differential diagnosis. Conventional imaging was evaluated by residents in our department of radiology and by their supervising attending physicians, who reviewed and discussed the images together with physicians from the infectious disease department. We also reviewed the necessity of oxygen supplementation, mechanical ventilation, and auscultation findings in these patients. We performed LUS in 17 COVID-19 patients (see Table 1 ) between the 6th of February and 1st of April 2020. The patients' age ranged from 30 to 68 years (median 51 years). CXR was performed in 13 patients; chest CT was performed in eight patients. In 2 patients, we did not perform any radiological imaging. Of the 17 patients, only 3 showed no pulmonary abnormalities at all, meaning that we saw A-Lines in all assessed intercostal spaces (ICS), no more than 2 b-Lines in any intercostal space, no irregular pleural line, and no consolidation. In 3 patients, we found small consolidations (no more than one ICS in longitudinal extent) with or without adjacent comet tail artifacts, but no ICS with 3 or more B-Lines. One patient had a small pleural effusion with a sagittal extent (between lateral chest wall and diaphragm) of 4 mm unilaterally, but no ICS with 3 or more B-Lines and no consolidation. In 9 patients, we found 3 or more B-Lines (see Figs. 1 and 2) in at least two ICS, in all these cases B-Lines were present bilaterally. Two of these had no other visible pathology other than B-Lines; two had small pleural effusion in their costodiaphragmatic recess up to 6 mm in sagittal extent (see Fig. 3 ), and five had detectable subpleural consolidation, 4 of which extended longitudinally for more than one ICS. We saw the most severe findings in a patient with severe ARDS (H orowitz Index 80.7mmHg) who showed extensive tissue-like and shred signs posterolaterally with numerous B-Lines anteriorly. One other patient had bilateral pleural plaques but no history of exposure to asbestos, silica or other dusts and no signs of interstitial involvement (see Fig. 3b ). In patients with interstitial pathologies, unaffected areas showing A-Lines with up to two b-Lines are more common in anterior regions. Views with 3 or more B-Lines and tissue or shred signs, if present, were more common in lateral and posterior regions. In 8 out of the 13 patients who had CXR performed, no pathological finding could be detected. In those 8 patients with inconspicuous CXR, 3 also had a CT performed. Only in one of those did the CT scan confirm absence of pulmonary pathology, the other two CTs showed subtle ground glass opacities (GGO) within the lungs. In 5 patients with inconspicuous CXR who did not have CT performed, LUS revealed subtle pulmonary pathologies in 3 patients. One of these was a case of bilateral pleural plaques seen on ultrasound (Fig. 3) but not on CXR. In all cases where CXR did show bilateral opacities, those were also seen on LUS. Conversely, not all pathologies that were detected using LUS were seen on CXR. In 8 patients who had received a CT scan of the chest, one did not show any pathologies. Of the other 7 patients, GGO and consolidations were seen in 4 cases in CT, and GGO only without consolidation in another 3 cases. None of the performed CT scans showed signs of PE. In one case, LUS revealed no interstitial pathology even though GGO were seen in the CT scan and the patient experienced respiratory distress. In one other case, LUS failed to detect interstitial pathology that was seen on CT but revealed a subtle pleural effusion. In the other 5 cases where CT revealed abnormalities, LUS showed corresponding abnormalities (B-Lines, consolidation) in affected intercostal spaces where CT indicated these pathologies. In patients who had a high degree of interstitial pathology indicated by B-lines, consolidations also tended to be more extensive. We would like to point out that 4 patients had very small consolidations that were not revealed on CXR. The patients were asymptomatic, their LUS only revealed A-Lines apart from small shred signs and we cannot rule out that we detected preexisting peripheral abnormalities that are not associated with COVID-19. LUS showed abnormalities corresponding to chest CT in 5 out of 7 cases. LUS showed any kind of abnormality in 6 out of 7 cases where CT was abnormal. This limited retrospective analysis demonstrates our experience with LUS in COVID-19 patients. This descriptive case series should indicate the potential of point-of-care LUS compared to radiographic imaging, particularly compared to CXR under IPC precautions. We detected three or more B-Lines in at least two ICS in 9 symptomatic COVID-19 patients and never in asymptomatic patients who tested positive for SARS-CoV-2. One patient with respiratory distress who showed interstitial involvement on CT did not have three or more B-Lines per ICS on LUS. As interstitial involvement progresses to ground glass opacities on CT, B-Lines become more numerous and confluent [7] (Fig. 2) , the pleural line from which they arise becoming more irregular. Similar results have been described in a recent letter [13] , in which the authors detected B-Lines in COVID-19 patients corresponding to GGO on chest CT. Compared to CT, LUS was reliable in detecting signs of interstitial disease in our patients. Scientific consensus suggests that LUS is superior to CXR in detecting interstitial abnormalities [4] which we can neither confirm nor dismiss in COVID-19 due to limited sample size. LUS in COVID-19 reportedly [13] reveals both small and large consolidations, which we confirm in our series: In 9 patients, we detected consolidations; in 5 cases, they did not extend over more than one ICS. We saw consolidations more frequently in lateral and posterior views, possibly corresponding to less aerated areas. As with any imaging modality, we see the necessity to evaluate imaging results in the context of Fig. 2 Comparison of exemplary lesions on CT and LUS. Left: GGO in the upper lobe of the right lung (double arrows) yield very densely converging B-Lines (horizontal arrows) that seem to merge into one broad, echogenic vertical artifact arising from the irregular pleural line (vertical arrows). Right: Thickened interlobular septa (arrowheads) are visible on CT; they correlate to B-Lines in LUS (horizontal arrows) that are still distinguishable from one another. The density of B-Lines seems to correlate to the extent of thickening in interlobular septa [7] . All images were obtained on day 17 after symptom onset clinical appearance, since very small consolidations could be detected in otherwise asymptomatic patients. As reported before [13] , pleural effusion is rare in COVID-19. We only detected pleural effusion in three patients. The instances of pleural effusion that we saw were always subtle, ranging no more than a few millimeters in sagittal orientation. Larger effusions in COVID-19 patients might be indicative of bacterial superinfection or cardiac pathologies; however, we did not see any such cases yet. One patient showed pleural plaques on LUS without history of occupational exposure to dusts or preexisting pleural disease. This is, to our knowledge, the first report of pleural plaques associated with COVID-19. However, we cannot conclude whether or not viral disease indeed caused these plaques. Another pulmonary pathology frequently seen in COVID-19 is pulmonary embolism (PE) [19] . Although none of the patients in our cohort showed PE on contrast-enhanced chest CT, LUS might turn out as a useful diagnostic tool in detecting this condition. On LUS, PE presents as peripheral tissue-like sign with absent perfusion (as demonstrated on color or power Doppler) [4, 17] . LUS is a viable alternative in diagnosing PE if CT is contraindicated or unavailable [4, 17] , offering similar diagnostic accuracy (see Table 2 ). Performing CTs in patients under high isolation precautions is difficult and may ultimately delay diagnosis, whereas LUS accelerates pulmonary diagnostics, particularly in acutely ill patients, as compared to radiologic studies [5] . Ultrasound is also useful in detecting concomitant deep vein thrombosis as surrogate indicator for PE in dyspnoeic patients with otherwise normal LUS [8] . The usefulness of ultrasound in COVID-associated PE has however not yet been investigated in large-scale, blinded studies and might be a promising topic for future research. Contrastenhanced ultrasound (CEUS) even discerns pneumonic consolidations and PE [20, 21] which may be a useful application particularly in COVID-19 where both PE and pneumonic consolidations are frequent findings. In non-COVID patients, lung ultrasound could also discern the severity of acute respiratory distress syndrome (ARDS) [22] , to which COVID can progress. We only saw one patient with ARDS who had the most extensive findings regarding the consolidations detected. Large studies correlating lung ultrasound findings to the disease severity of COVID-associated ARDS might be desirable in order to establish this method in this setting. Conclusively, asymptomatic patients rarely show interstitial involvement (more than three B-Lines per ICS) on lung ultrasound, and the minute consolidations or pleural abnormalities that we did find in asymptomatic patients may or may not be attributable to COVID-19. Patients in respiratory distress show signs of interstitial disease, usually several regions with multiple B-Lines per ICS in asymmetric patterns and varying consolidations. This brief report is obviously very limited, and as we did not perform all imaging modalities in each patient, we cannot conclude or prove which is superior. We could not systematically analyze LUS due to limited sample size and because we inconsistently performed conventional imaging or invasive diagnostics, based on the patients' differing disease severity. LUS cannot access the entire lung surface, and one should keep in mind that LUS will not detect abnormalities at all if they do not reach the pleura. Furthermore, ultrasound is generally considered operator-dependent and requires a learning period. We do however see indications that LUS suitable for detecting the subtle interstitial and alveolar pathologies of viral SARS-CoV-2 pneumonia. LUS might be considered especially for use under IPC measures necessary for COVID-19. As cases are expected to rise, we anticipate more extensive use Note that this effusion was too small to be seen on CT in the supine patient; as fluid collects in the costodiaphragmatic recess in the sitting patient, it was detected using LUS. (b) Pleural plaque in posterior lung scan. Two anechoic lesions (horizontal arrows) are seen adjacent to the parietal pleura. The differential diagnosis of consolidation is dismissed with dynamic visualization of the visceral pleura (vertical arrow) sliding past the stationary lesion; the differential diagnosis of an effusion is dismissed due to the stationary nature of the lesion, (1) not descending into the costodiaphragmatic recess upon inspiration and (2) lack of respiration-dependent expansion and contraction of LUS in COVID-19 as it can be done at bedside under quarantine precautions, accelerates diagnostic imaging [5] , and can be repeated numerous times without exposing patients to radiation. We would like to encourage future research to compare LUS to CT in large studies as available literature at this point rarely reports on sensitivity or specificity of LUS (see Table 2 ). No additional data to be deposited. Authors' Contributions DM drafted the original concept, TW and FB reviewed parts of the manuscript. FB contributed clinical data and parameters of the patients. TW and DM performed LUS examinations. VJ evaluated radiographic scans and provided CT imaging materials. HN is an attending physician in the ICU and provided detailed insights regarding our critically ill patients. All authors were involved in patient care and helped finalize the text and content. Funding Open Access funding enabled and organized by Projekt DEAL. Conflict of Interest The authors declare that they have no conflict of interest. Ethics Approval The retrospective study received ethics clearance based on the patient consent form. Consent to Participate and Consent for Publication All patients declare their approval for participation in this study. Code Availability Not applicable. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. Table 2 Overview of systematic reviews and studies of different imaging modalities in COVID and PE. Note that large-scale reviews on LUS in COVID are missing data on sensitivity or specificity, as they mostly rely on case series not reporting this information. Future trials to assess these specifications are desirable. There are also no studies available on LUS in COVID-associated PE. Outbreak of pneumonia of unknown etiology in Wuhan China: the mystery and the miracle Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and coronavirus disease-2019 (COVID-19): the epidemic and the challenges Pneumonia: does ultrasound replace chest X-ray? Praxis International evidence-based recommendations for point-of-care lung ultrasound The impact of the BLUE protocol ultrasonography on the time taken to treat acute respiratory distress in the ED Lung ultrasound in community-acquired pneumonia and in interstitial lung diseases The comet-tail artifact: an ultrasound sign of alveolar-interstitial syndrome Whole Body Ultrasonography in the Critically Ill Advanced imaging use in intensive care units has decreased, resulting in lower charges without negative effects on patient outcomes The use of point-of-care bedside lung ultrasound significantly reduces the number of radiographs and computed tomography scans in critically ill patients Implementation of lung ultrasound in polyvalent intensive care unit: impact on irradiation and medical cost Chest CT findings in 2019 novel coronavirus (2019-nCoV) infections from Wuhan, China: key points for the radiologist Findings of lung ultrasonography of novel corona virus pneumonia during the 2019-2020 epidemic Diagnostic performance of CT and reverse transcriptase-polymerase chain reaction for coronavirus disease 2019: a meta-analysis Point-of-care lung ultrasound in patients with COVID-19 -a narrative review Frequency of abnormalities detected by point-of-care lung ultrasound in symptomatic COVID-19 patients: systematic review and meta analysis Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis Chinese multi-center study of lung scintigraphy and CT pulmonary angiography for the diagnosis of pulmonary embolism Pulmonary embolism in patients with COVID-19 pneumonia Contrast-enhanced ultrasound of embolic consolidations in patients with pulmonary embolism: a pilot study Contrast-enhanced ultrasound does not discriminate between community acquired pneumonia and lung cancer The diagnostic accuracy for ARDS of global versus regional lung ultrasound scores -a post hoc analysis of an observational study in invasively ventilated ICU patients Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations