key: cord-0734833-nqyw4zwz authors: Lin, Yen-Hung; Han, Yang; Sharma, Abhinav; AlGhamdi, Wejdan S.; Liu, Chien-Hao; Chang, Tzu-Hsuan; Xiao, Xi-Wen; Seitkhan, Akmaral; Mottram, Alexander D.; Pattanasattayavong, Pichaya; Faber, Hendrik; Heeney, Martin; Anthopoulos, Thomas D. title: An all-solid-state heterojunction oxide transistor for the rapid detection of biomolecules and SARS-CoV-2 spike S1 protein date: 2021-01-19 journal: bioRxiv DOI: 10.1101/2021.01.19.427256 sha: fc777edf8e82ee271ebb42104d63007efbb56740 doc_id: 734833 cord_uid: nqyw4zwz Solid-state transistor sensors that can detect biomolecules in real time are highly attractive for emerging bioanalytical applications. However, combining cost-effective manufacturing with high sensitivity, specificity and fast sensing response, remains challenging. Here we develop low-temperature solution-processed In2O3/ZnO heterojunction transistors featuring a geometrically engineered tri-channel architecture for rapid real-time detection of different biomolecules. The sensor combines a high electron mobility channel, attributed to the quasi-two-dimensional electron gas (q2DEG) at the buried In2O3/ZnO heterointerface, in close proximity to a sensing surface featuring tethered analyte receptors. The unusual tri-channel design enables strong coupling between the buried q2DEG and the minute electronic perturbations occurring during receptor-analyte interactions allowing for robust, real-time detection of biomolecules down to attomolar (aM) concentrations. By functionalizing the tri-channel surface with SARS-CoV-2 (Severe Acute Respiratory Syndrome Coronavirus 2) antibody receptors, we demonstrate real-time detection of the SARS-CoV-2 spike S1 protein down to attomolar concentrations in under two minutes. surface-area-to-volume ratio (10 6 cm 2 cm -3 ) and facilitates nm-proximity between the 1 electrostatic perturbations occurring during surface-tethered receptor and analyte interaction, 2 with the buried q2DEG channel. These unique features enable simultaneous signal transduction 3 and amplification in an all-solid-state TFT platform enabling real-time detection of specific 4 biomolecules down to attomolar (aM) concentrations under physiological relevant conditions. 5 As a proof-of-concept we demonstrate selective sensing of the SARS-CoV-2 (Severe Acute 6 Respiratory Syndrome Coronavirus 2) spike S1 protein in real-time with a limit of detection 7 (LoD) of 865 aM. Quasi-two-dimensional oxide heterojunction channel 10 We hypothesised that our recently developed solution-processed, high electron mobility 11 In2O3/ZnO heterojunction (HJ) transistors 30 offers unique features that could prove attractive 12 for biosensing. Firstly, the buried electron channel located at the oxide HJ is physically 13 separated from the receptor units tethered on its surface a few nm above 31,32 . This feature is 14 expected to prevent degradation of electron transport upon sensing (due to Coulomb scattering) 15 and preserve the transistor's performance. This is not the case for most biosensor transistors 16 reported to date where the channel interacts directly with the receptor units and hence the 17 analyte. To overcome this, liquid gating has been exploited for analyte detection in the liquid 18 phase 6, 22, 33 . Secondly, the high electron mobility of the HJ TFTs offers the possibility for large 19 electrical signals that are easy to detect and amplify even in large-size devices 31 . 20 We fabricated metal oxide HJ transistors using the staggered bottom-gate, top-contact 21 (BG-TC) architecture shown in Fig. 1a . High-resolution transmission electron microscopy 22 (HRTEM) analysis (Fig. 1b) of the channel reveals the formation of a well-defined HJ channel 23 with thickness in the range of 8-10 nm. Atomic force microscopy (AFM) measurements show 24 the existence of smooth layers as being deposited sequentially (Fig. 1c-d) . In2O3 exhibits the 25 lowest peak-to-peak height (Z) of 1.87 nm with a root-mean-square roughness (RMS) value 26 of 0.20 nm, which are comparable to that of SiO2 (Z = 1.91 nm, RMS = 0.21 nm). Subsequent 27 deposition of ZnO atop In2O3 leads to a slightly rougher topography (Z = 4.00 nm, RMS = 28 0.58 nm) indicative of a more textured surface 31, 34 . 29 The In2O3/ZnO forms a type-II heterojunction where electrons migrate from the 30 conduction band (CB) of ZnO to that of In2O3, leading to the formation of a q2DEG (Fig. 1e) 32 . 31 The latter resembles 2DEG systems found in high electron mobility transistors (HEMTs) based 32 on epitaxial inorganic heterointerfaces 35 . Although uncommon, the existence of q2DEG in disordered/non-epitaxial heterointerfaces has been predicted, further corroborating our 1 findings and conclusions 36 . Fig. 1f and 1g show representative sets of transfer and output 2 current-voltage (I-V) characteristics for a In2O3/ZnO HJ transistor with electron mobility and 3 current on-off ratio of >22 cm 2 V -1 s -1 and >10 8 , respectively. The presence of the q2DEG 4 system at the In2O3/ZnO interface is responsible for the electron current across the channel and 5 the high electron mobility measured 32 . All solid-state tri-channel transistor sensor 1 To investigate the suitability of the In2O3/ZnO transistors for biosensing, we fabricated devices 2 based on a tri-channel configuration on 4-inch Si wafers (Fig. 2a) . The source-drain (S-D) 3 electrodes are deposited atop the In2O3/ZnO channel followed by the deposition of another 4 ultrathin (2-4 nm) protective ZnO layer. Next the known deoxyribonucleic acid (DNA) 5 intercalator 37,38 1-pyrenebutyric acid (PBA) was functionalised directly to ZnO 39 acting as the 6 DNA receptor. A second functionalisation step using butyric acid (BA) was also applied to transistor measured by SKP. The WF for the embedded Al-electrode areas is measured to be ≈ To better understand the electrostatic potential landscape across our unconventional tri-26 channel device, we performed scanning Kelvin probe (SKP) measurements (Fig. 2e) . To understand how the tri-channel geometric impacts the electrical characteristics of 15 the sensor, we modelled the device operation using the COMSOL Multiphysics ® simulation 16 software. Fig. 3a shows the simulated and measured transfer characteristics for a representative 17 transistor. The various material and device parameters used in the modelling were adopted from our previous studies on the same materials 31,44,45 . The small difference seen in the subthreshold 1 region between the modelled and experimental data is attributed to the presence of trap states 2 in the channel 46,47 , while the higher off current measured experimentally is due to the use of a 3 common Si ++ gate substrate and the un-patterned layout of the In2O3/ZnO channel. Apart from 4 these minor discrepancies, the model provides a good description of the tri-channel transistor 5 operation and validates its applicability. 6 The main function of a transistor biosensor is to induce a perturbation in the channel 7 current upon exposure to an external stimulus (analyte). To best illustrate this process in our unaltered when the additional electron concentration remains below 10 17 cm -3 . 34 To ensure that 21 this condition is satisfied, we used a more conservative estimation for the analyte-induced 22 electron concentration of 10 16 cm -3 and a channel thickness of 10 nm (Fig. 1b) . The equivalent 23 surface charge density due to analyte was then derived from the modelling yielding a value of 24 ≈10 10 cm -2 , which will be considered for the different device operating scenarios next. Strikingly, we find that unlike the geometrically engineered heterojunction In2O3/ZnO 5 transistors ( Fig. 3h-l) , electron flow in the In2O3 device is pinned at the interface with the gate 6 dielectric while being fully decoupled from the surface/analyte (Supplementary Figure 8b) . 7 From these data we conclude that the tri-channel design is highly sensitive to the presence of shows much stronger coupling to the analyte. Specifically, we find the electron flow 18 streamlines to extend ≈1 nm beneath the SC surface ( Fig. 3h-l) due to the asymmetric design 19 of the source-drain electrodes 50 , which prevent the local electric field to fully pinch-off the 20 channel for VG between -1 to 1 V. As the VG increases (+20 V), the benefits associated with 21 the presence of a q2DEG in the In2O3/ZnO become even more apparent as the area beneath the 22 sensing surface remains free from electrostatic screening induced by the gate (Fig. 3l) . 23 Nevertheless, it is known to be more advantageous for solid-state transistor sensors to be 24 operated within the subthreshold region as it yields optimal sensitivity due to high signal gain 51 . Receptor engineering for ultra-sensitive and real-time biosensing 27 To demonstrate that the working principle of our all-solid-state tri-channel transistor is 28 fundamentally different from that of conventional liquid-gated sensors, we studied the ability 29 of our transistors to detect different types of DNAs (analytes) dispersed in deionised (DI) water 30 rather than in a high ionic strength solution. We note that the latter is essential for the function 31 of liquid-gated transistor sensors in order to drive the analyte towards the semiconducting 32 channel, which in turn modulates its transconductance via electrochemical processes 6 . To prove 33 that our sensors do not rely on such processes, the DI-water based solutions containing double-stranded DNA (dsDNA) and single-stranded DNA (ssDNA) of different sequences, were 1 applied directly onto the SC area while recording the device's response. involving the single-stranded A20 (Fig. 4c) and T20 (Fig. 4d) where only minute changes are 16 observed in the transistors' characteristics due to the absence of pyrene-NDA intercalation. isotherm. The error bars denote standard deviations from three real-time measurement sets. 16 17 In an effort to quantify the sensor's response, we analysed the change in VON as a (Fig. 4b) . The large ΔID indicates that the actual sensitivity of the tri-31 channel sensors is well below 100 aM. To this end, we note that in the literature the most 32 frequently reported parameter is the LoD, which is determined by the minimum detectable 33 signals that are often far from suitable for real-time monitoring 5,6,41,56 . To further demonstrate the capabilities of our high Sanalyte sensor, we analysed the 1 sensing kinetics using the linear form of the Langmuir adsorption isotherm 57,58 . (iii) Dissociation of analyte-receptor complexes before reaching a thermodynamic 12 equilibrium. The rate of the 'primary' sensing process depicted in Supplementary Figure 14b is 14 representative of a zero-order reaction and is independent of the analyte concentration or the 15 method with which the analyte solution is being applied. For each concentration, a distinct peak 16 between association and dissociation stages is observed and attributed to the immobilisation of 17 analyte species by the tethered receptors 59-61 . Therefore, and regardless of the sensing method, 18 the existence of two-phase kinetics relates solely to the association and dissociation stages. 19 Using the high fidelity sensing data from Supplementary Figure 14 , the equilibrium constant 20 (Keq) was calculated yielding values of (5.88 ± 0.03) ´ 10 8 M -1 (Fig. 4h) . 21 In addition to short synthetic DNA, we have also tested natural dsDNA extracted from 22 calf thymus tissue, which has much longer DNA sequences. Fig. 5a for (AT)20 indicating that the sensing mechanism remains identical for the natural dsDNA. Even when aM concentration of the dsDNA is applied, the recorded signal (ΔID/I0) increases 27 by more than 100× (inset of Fig. 5b) , further corroborating the unprecedented sensitivity of 28 the tri-channel sensor. When compared to (AT)20, the sensor exhibits stronger response to 29 natural dsDNA with a higher binding constant Keq of (8.71 ± 0.01) ´10 9 M -1 (Fig. 5c) . This biotin-avidin) analytes. In the case of biotin-avidin interaction the channel current was found 16 to reduce due to the electron accepting nature of the formed complex. Another important 17 feature of the tri-channel sensor is the large size SC and its ability to accommodate a high 18 density of receptors which in turn enable dynamic sensing over an extraordinary wide range of 19 analyte concentrations (Supplementary Figure 14) . Detection of SARS-CoV-2 spike S1 protein 22 To demonstrate the potential of the tri-channel transistors in a real-world sensing scenario, we 23 engineered the surface of the SC by immobilizing SARS-CoV-2 antibody acceptors designed 24 for specific binding to the SARS-CoV-2 spike S1 protein (Fig. 6a) Figures 17 and 18) . Next, a series 4 of PBS solutions containing different concentrations of the SARS-CoV-2 spike S1 protein were 5 prepared and applied to the SC of the sensor while the transfer characteristics were recorded 6 for each analyte concentration (Fig. 6b and Supplementary Figure 19a) . A clear and 7 systematic shift in VON towards more negative gate voltages with increasing analyte 8 concentration, is observed. Strikingly, even at 10 aM the sensor's response remains large and 9 clearly visible in the quasi-static transfer characteristics of Fig. 6b indicating a high sensitivity. To further demonstrate the versatility of the tri-channel sensor, we performed real-time 21 sensing measurements of the SARS-CoV-2 spike S1 protein. Prior to this the sensor was biased (Supplementary Figure 19b) . Evidently, the sensor can detect the analyte across an ultra-3 wide range of concentrations (aM to pM) demonstrating the tremendous potential of the 4 technology. Similar to dsDNA real-time sensing data, the recorded signal (ΔID/I0) for each 5 concentration increases and reaches an equilibrium followed by a small deep due to the 6 diffusion limited, association and dissociation stages discussed previously (Supplementary 7 Figure 14b ). 8 Lastly, we evaluated the specificity of our sensor towards the SARS-CoV-2 spike S1 9 protein by comparing its real-time response against that of Middle East respiratory syndrome 10 coronavirus (MERS-CoV) spike protein due to their genome similarities 66 . As can be seen in 11 Fig. 6c , the tri-channel sensor can differentiate between the two proteins under physiological 12 relevant conditions. For the MERS-CoV protein, the sensor shows no response with the signal 13 remaining largely unaltered with increasing analyte concentration from 1 fM to 100 pM. On 14 the contrary, exposure of the device to SARS CoV-2 spike S1 protein leads to a strong and 15 systematic signal increase with increasing SARS-CoV-2 spike S1 protein concentration. The 16 lowest concentration at which these differences are detectable can be deducted from on sample via sputtering before the sample preparation to make its surface more conductive. The HRTEM images were acquired at 300 kV by a FEI Titan G2 80-300 microscope equipped 26 with a high-brightness Schottky-field emission electron source and a high-resolution Gatan 27 imaging filter Tridiem energy-filter. Real-time sensing data analysis of (AT)20, natural dsDNA from calf thymus and avidin. 13 The sensors' real-time recordings to synthetic dsDNA (AT)20 (Fig. 4h) Keq is the binding constant of the analyte with its corresponding receptor. 18 19 Solution preparation and device fabrication for spike S1 protein sensing experiments. The CoV-2 spike S1 antibody (40150-R007), SARS-CoV-2 (2019-nCoV) Spike S1-His 23 Recombinant Protein (40591-V08B1), MERS-CoV Spike/S1 Protein (S1 Subunit, aa 1-725, The authors declare no competing financial interests. Biosensors as useful tools for 27 environmental analysis and monitoring Supersensitive Detection of Explosives by Silicon Nanowire Arrays Transparent Stretchable Self-Powered Patchable Sensor Platform with 31 Ultrasensitive Recognition of Human Activities Silicon Nanowires via Silicon nanowire sensor array using top-down CMOS technology A-Phys. 145-146 Modified Nanotransistor Sensor Arrays as a Direct Biomarker Detection Method in 17 Metal oxides for optoelectronic applications Ultrathin channels make transistors go faster Electrical Responses of Artificial DNA Nanostructures on Solution-1 Processed In-Ga-Zn-O Thin-Film Transistors with Multistacked Active Layers Approaches to label-free flexible DNA biosensors using low-temperature 4 solution-processed InZnO thin-film transistors Quasi-Two-Dimensional Metal Oxide Semiconductors Based Fabrication of High-Performance Ultrathin In2O3 Film Field-Effect 8 Transistors and Biosensors Using Chemical Lift-Off Lithography Biofuel powered glucose detection in bodily fluids with an n-type 11 conjugated polymer Beyond the Debye length in high ionic strength solution: direct protein 15 detection with field-effect transistors (FETs) in human serum An electrochemical biosensor to simultaneously detect VEGF and PSA 17 for early prostate cancer diagnosis based on graphene oxide/ssDNA/PLLA nanoparticles Biorecognition Layer Engineering: Overcoming Screening Limitations 20 of Nanowire-Based FET Devices Hybrid Modulation-Doping of Solution-Processed Ultrathin Layers of 1 ZnO Using Molecular Dopants Electron mobilities in 3 modulation-doped semiconductor heterojunction superlattices Uv Resonance Raman Studies of DNA Pyrene Interactions Optical Decoupling Raman-Spectroscopy Selectively Examines External Site Bound 9 DNA-intercalation on pyrene modified 11 surface coatings Surface modification of zinc oxide 13 nanoparticle by PMAA and its dispersion in aqueous system Identifying the Mechanism of Biosensing with Carbon Nanotube 16 Transistors Fabrication of High-Performance Ultrathin In2O3 Film Field-Effect 18 Transistors and Biosensors Using Chemical Lift-Off Lithography Robust graphene-based molecular devices Present status of amorphous In-Ga-Zn-O thin-1 film transistors Negative gate-bias temperature stability of N-doped InGaZnO active-layer 3 thin-film transistors Development of an AC electrokinetics-based immunoassay system for on-5 site serodiagnosis of infectious diseases Subthreshold Regime has the Optimal Sensitivity 7 for Nanowire FET Biosensors DNA-intercalation on pyrene modified 9 surface coatings Solution-processed ZnO 11 nanoparticle-based transistors via a room-temperature photochemical conversion process Pyrene-labeled deoxyguanosine as a fluorescence sensor to 14 discriminate single and double stranded DNA structures: Design of ends free molecular 15 beacons Label-free biomarker detection from whole blood Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human 18 Quantitative detection of protein using a top-gate carbon nanotube field 21 effect transistor Quantification of the affinities and kinetics of protein interactions using 23 silicon nanowire biosensors Label-free measuring and mapping of binding kinetics of membrane 25 proteins in single living cells Quantification of the affinities and kinetics of protein interactions using 27 silicon nanowire biosensors Real-time reliable determination of binding kinetics of DNA hybridization 29 using a multi-channel graphene biosensor The Application of Terahertz Spectroscopy to Protein 31 Detection: A Review Advances in Protein Chemistry