key: cord-0732126-6kj3rv20 authors: Sobczyk, Juliana; Pyne, Michael T.; Barker, Adam; Mayer, Jeanmarie; Hanson, Kimberly E.; Samore, Matthew H.; Noriega, Rodrigo title: Efficient and effective single-step screening of individual samples for SARS-CoV-2 RNA using multi-dimensional pooling and Bayesian inference date: 2021-06-16 journal: Journal of the Royal Society, Interface DOI: 10.1098/rsif.2021.0155 sha: 4d615ef247f8ad0273758351cba7529926617d63 doc_id: 732126 cord_uid: 6kj3rv20 Rapid and widespread implementation of infectious disease surveillance is a critical component in the response to novel health threats. Molecular assays are the preferred method to detect a broad range of viral pathogens with high sensitivity and specificity. The implementation of molecular assay testing in a rapidly evolving public health emergency, such as the ongoing COVID-19 pandemic, can be hindered by resource availability or technical constraints. We present a screening strategy that is easily scaled up to support a sustained large volume of testing over long periods of time. This non-adaptive pooled-sample screening protocol employs Bayesian inference to yield a reportable outcome for each individual sample in a single testing step (no confirmation of positive results required). The proposed method is validated using clinical specimens tested using a real-time reverse transcription polymerase chain reaction test for SARS-CoV-2. This screening protocol has substantial advantages for its implementation, including higher sample throughput, faster time to results, no need to retrieve previously screened samples from storage to undergo retesting, and excellent performance of the algorithm's sensitivity and specificity compared with the individual test's metrics. Epidemiological strategies to control the spread of infectious respiratory diseases include contact, droplet and/or aerosol precautions, asymptomatic screening, contact tracing, case isolation, ring containment and social distancing [1] [2] [3] [4] [5] [6] [7] . While the specific set of strategies employed depends on the aetiological agent, the use of microbiological and molecular testing to identify disease cases is a crucially important element. In general, two key parameters for the performance of a diagnostic test are its sensitivity (a measure of its ability to correctly detect a positive case) and its specificity (a measure of its ability to only yield a positive result for the agent in question). Reducing the sensitivity of a test leads to an increase in false-negative results; a reduction in the specificity leads to an increase in falsepositive-results. For practical purposes, other considerations for deploying diagnostics tests can include their ease of use, portability, cost and throughput. The present COVID-19 pandemic has caused significant public health challenges, which have been compounded by resource constraints and the unprecedented scale of testing required to effectively control its spread [8] [9] [10] [11] [12] [13] . To solve these challenges, sample pooling has been proposed as a means to scale up screening at a population level and to assess the prevalence of the disease [14] [15] [16] [17] [18] [19] [20] . However, currently available pooling protocols have significant limitations. First, the requirement of retesting individual samples for the identification of positive cases incurs substantial logistical challenges when screening a large number of samples at a constant rate for a prolonged period of time. Second, multi-dimensional pooling strategies that identify cases via the intersection of positive pools suffer from reduced performance when imperfect tests are used (i.e. sensitivity and/or specificity less than 100%). Finally, while high viral load samples can be diluted by pooling and still yield accurate test results, dilution of low viral load samples into large pools at low prevalence rates lowers the sensitivity of pooled tests [14] . Limiting the size of pools can reduce the effect of sensitivity loss, but it also reduces efficiency gains. Here, we report a screening strategy that employs multidimensional sample pooling and applies Bayesian inference to provide reportable results at the individual level in a single testing step. This strategy increases testing throughput with minimal or no loss of sensitivity over a reasonable range of disease prevalence. Importantly, this strategy is easily scalable to support a sustained large volume of testing over long periods of time. In standard two-stage one-dimensional (1D) sample pooling (figure 1a), specimens from N s patients are randomly pooled into groups of m samples each. Pooled samples are interrogated with the diagnostic test. If pooled testing yields a negative result, no further testing is conducted and all samples in that pool are assigned a negative result. If pooled testing yields a positive result, all patients in that pool are tested individually. This adaptive protocol, known as Dorfman pooling, was introduced in the 1940s, and subsequent developments include multiple levels of hierarchical testing where positive pools are divided into smaller pools until testing at the individual level is reached [21] [22] [23] [24] [25] [26] . Adaptive pooling methods can yield considerable improvements in sample throughput, especially at low prevalence. However, large efficiency gains require large pool sizes and are affected by a reduction in sensitivity because of dilution. Some adaptive pooling strategies include an intermediate pool design step to maximize the information gained with each round of tests, increasing the algorithm efficiency [27] . Even without intermediate pool design steps, the logistical complications of retrieving samples belonging to positive pools and the need to undergo multiple rounds of testing can negatively impact the time required to identify positive specimens. To circumvent the drawbacks of adaptive pooling, various non-adaptive pooling methods in multiple dimensions have been introduced (e.g. shifted transversal design) [28] [29] [30] [31] . In a simple example of two-dimensional (2D) nonadaptive pooling, specimens are arranged in a matrix and samples are pooled along each row and along each column (figure 1b). Positive specimens are identified by the intersections of rows and columns that yield a positive test result, which requires close-to-ideal test characteristics. Non-adaptive screening methods have been developed to account for non-idealities [32] , and similar tools used for DNA library screening have included Markov chain analysis and Bayesian probability estimation to interpret test results [33] . Here, we present a non-adaptive multi-dimensional pooling method that incorporates Bayesian inference to assess the probability of all individual specimens, and we explore the effects of dimensionality, pool size and test characteristics on its performance, efficiency and complexity. The result of a diagnostic test can be evaluated with a Bayesian probability formalism [34] [35] [36] . In the context of an individual sample, this analysis takes into account the probability of Figure 1 . Visual representation of three pooled-sample approaches to screen 64 specimens, one of which is positive (marked in red), using (a) two-stage adaptive 1D pooling, (b) non-adaptive 2D pooling based on the intersection of positive pools and (c) non-adaptive 3D pooling with Bayesian inference. Pools that contain the positive specimen are highlighted, and in the case of 3D pooling, copied outside of the cube for clarity. detecting a positive case (sensitivity, Se) and the probability of a positive result from healthy samples (whose complement is the specificity, Sp). Bayesian inference requires the assessment of a prior probability for the presence of disease in a sample, P(D), which is updated to a posterior probability given a positive/ negative test result with conditional probabilities P(Djþ) or P(DjÀ), as shown in the following equations: where Se is the test's sensitivity and P pool ( þ ) is the overall probability of the pool yielding a positive test outcome. The probability of a positive result in a pooled sample is based on all prior probabilities for specimens in the pool. Upon extension to pooled-sample testing, a pool size-dependent reduction in test sensitivity is included by assuming that a fraction g of truepositive specimens will be diluted below detectable levels due to pooling (details in electronic supplementary material, figure S1 and accompanying supplementary text). In this way, the probability of a positive test result in a pool is the sum of two contributions: the probability of having a non-zero number of detectable positive individual specimens multiplied by the test's sensitivity; and the probability of a sample without a single detectable positive specimen multiplied by the false-positive rate P fp ¼ 1 À Sp (equation (2.2)): where i is a dummy index that runs over all samples belonging to the pool. Here, we consider N s specimens arranged in a d-dimensional hypercube of size {m 1 , m 2 , …, m d }. Pools are constructed for all samples that form a line along a particular axis. Using the test outcome for each pooled sample, the posterior probabilities of all specimens belonging to it are calculated with a Bayesian inference step (equations (2.1a,b) and (2.2)). The posterior probability resulting from the application of equations (2.1a,b) and (2.2) to the test outcomes in each hypercube surface (i.e. from each pooling dimension) is used as a prior for the next round of posterior probability calculations along the next pooling dimension. Because of imperfect test characteristics and the possibility of multiple positive specimens belonging to the same pool at increased disease prevalence rates, not every surface of the hypercube contains the same number of positive test results. Therefore, the order in which we use the information contained in each of these surfaces can affect the posterior probability assigned to individual samples and thus their screening outcome. To account for this situation, we consider all d! permutations of the hypercube surfaces and include only those in which the number of positive tests follows an increasing (or flat) trend. For each one of such permutations, the posterior probability of all samples is calculated. The reported disease probability for each specimen is the largest value obtained among all the considered permutations (example distributions of posterior probabilities in electronic supplementary material, figures S2 and S3). A posterior probability threshold is used to assign a positive or negative screening result-lowering its value increases the algorithm sensitivity and reduces its specificity (electronic supplementary material, figures S4 and S5). A three-dimensional (3D) example with equal pool size m ¼ 4 for all dimensions is shown in figure 1c . Importantly, this pooling method has minimal pool overlap ( pools share at most one common specimen). In the case of equal-sized pools for all dimensions, the number of specimens is N s ¼ m d and the number of tests is N t ¼ d Á m dÀ1 . Thus, pool size must be larger than the algorithm dimensionality to yield efficiency gains, as the number of tests required per specimen is x ¼ d=m. We implemented this protocol with Monte Carlo simulations as a function of disease prevalence (P D ¼ 0:5À10%), pool size (m ¼ 2À16) and dimensionality (d ¼ 3À4). For each set of simulation conditions, 10 3 -10 4 hypercubes are generated and analysed. Each individual sample is randomly assigned a +/− state according to the average prevalence rate. To incorporate sensitivity loss due to pooling, a pool size-dependent fraction g of the positive samples is designated as 'undetectable' and will not yield a true-positive test result upon pooling. Sensitivity loss is estimated using a large observational dataset of reverse transcription polymerase chain reaction (RT-PCR) cycle threshold numbers from positive clinical results (electronic supplementary material, figure S1 ). Pools that contain at least one detectable positive specimen yield a truepositive result with probability Se ¼ 95%; pools without a detectable positive specimen yield a false-positive result with probability 1 À Sp ¼ 1%. For each hypercube, simulated test outcomes are used to compute the posterior probabilities for individual samples. The threshold for a positive screening outcome is set to a posterior probability of 40% or higher, selected on the basis of the ratio of known-positive and known-negative specimens at each posterior probability outcome in large-scale Monte Carlo simulations using the test characteristics detailed above (for details, see electronic supplementary material, figure S4 and accompanying text). At low-to-moderate prevalence rates, it is possible to increase throughput without reducing the sensitivity or specificity of the pooled screening compared with the individual test ( figure 2a,b) . In fact, at low prevalence, this pooled testing protocol yields higher sensitivity than the individual test because the small number of positives leads to a low probability of overlap and each sample is included in d tests (d is the algorithm dimensionality). As long as the sample is not diluted below the detection limit, these multiple tests effectively reduce the chances of a false negative. First, let us consider the prevalence range in which the pooled testing algorithm yields improved or equivalent test performance metrics. For a 3D implementation of the algorithm, a 33% increase in the sample throughput can be achieved for prevalence rates of up to 5% without any loss in sensitivity or specificity. For prevalence rates below 2%, the efficiency gains can be greater than a 2× factor without any reduction in performance. In a four-dimensional (4D) implementation, the higher algorithm dimensionality leads to an increase in the amount of information gathered via pooled testing at the cost of smaller efficiency gains: a 25% increase in efficiency, without performance losses, can be sustained up to an approximately 7% prevalence rate. An improvement in specificity is also observed, as expected for both adaptive and non-adaptive pooling (electronic supplementary material, figure S6) . As a comparison, we contrast the optimal screening efficiency achieved in our proposed method with that in a twostage 1D adaptive pooling with overall sensitivity of 90% (figure 2c). This sensitivity reduction reflects the 95% agreement criteria between new and established protocols set forth by the US Food and Drug Administration for the Emergency Use Authorization of new molecular diagnostics [37] , a royalsocietypublishing.org/journal/rsif J. R. Soc. Interface 18: 20210155 stricter criterion than the 85% positive agreement for pooled testing [38] . For 3D and 4D pooling protocols that retain an overall sensitivity of Se pool ! 90%, the throughput gains are smaller than those obtained with the adaptive 1D algorithm (e.g. at 2% prevalence the number of patients screened per test is 3.55, 2.33 and 2.75 for 1D, 3D and 4D, respectively). However, we note that it is possible for 3D and 4D pooled screening to retain the full sensitivity of an individual test and yield efficiency gains-at 2% prevalence, 1.67 and 2 patients are screened per test in 3D and 4D algorithms with Se pool ! 95%, respectively. Supplementary Monte Carlo simulations focused on low prevalence and low viral load populations can be found in electronic supplementary material, figure S7. We implemented this protocol with 64 specimens initially screened as clinical samples at ARUP Laboratories. All samples were collected as nasopharyngeal swabs in phosphate-buffered saline (PBS) solution. Specimens were selected from the post-screening sample bank (frozen at −20°C) and were stripped of all protected health information. Three known positives were included in the pools, one of which (specimen 1) was flagged for serial dilutions (1×, 5× or 25× dilution in PBS) to explore the effects of dilution on test sensitivity. Besides specimen 1, all other specimens were randomly ordered (specimens 2-64). All specimens were individually retested in a control run, and 48 pools were prepared according to the previously described pooling arrangement with dimensionality d ¼ 3 and pool size m ¼ 4 (electronic supplementary material, tables S1-S2). Three repeat instances of the pooling arrangement were prepared, each one identical except for the serial dilution of specimen 1. Individual and pooled samples were tested using the Hologic Panther Fusion SARS-CoV-2 platform at ARUP Laboratories (outcomes in electronic supplementary material, tables S3-S6) [39] . Pooled test results were analysed with an automated Bayesian inference process whose output consists of the posterior probabilities for each individual specimen, and its only inputs are the estimated sensitivity loss due to pooling, the sensitivity and specificity of the individual test, and a list of pooled test results. In the control run, two out of the three known-positive, undiluted specimens were correctly identified, while a knownpositive sample yielded an invalid test result (test could not be repeated because of limited residual specimen volume). After a 5× dilution, specimen 1 was still detectable, and its cycle threshold number increased from C t ¼ 33:9 to C t ¼ 36:5 (for ideal-efficiency PCR, DC t ¼ log 2 (5) ¼ 2:3). After 25× dilution, specimen 1 yielded a negative result in its control test. In addition, there were two samples whose initial clinical result was negative but yielded a positive result when tested as part of the control set (repeat tests were negative, although it is possible they are positives close to the limit of detection). We thus estimate the overall sensitivity in this control run as Se ¼ 3=5 ¼ 60% (two undiluted + one diluted positives detected out of three undiluted + two diluted known positives), and the specificity as Sp ¼ 59=61 ¼ 96:7% (two false positives out of 61 known negatives). Posterior probabilities for all samples in the pooled screening trials are shown in figure 3. In the pooled screening run whose inputs are undiluted specimens (figure 3a), all three known positives are correctly identified and one false positive is reported (100% sensitivity and 98.4% specificity). The pooled screening run which included a 5× dilution of specimen 1 yielded results with 100% sensitivity and specificity (figure 3b). Upon further dilution (25×) of specimen 1, the sensitivity of the pooled screening algorithm was reduced We present a pooled-sample testing methodology whose performance is explored with Monte Carlo simulations and validated experimentally, and show that it can retain high sensitivity even at moderate prevalence rates while also improving specificity and throughput. The increases in sensitivity and specificity gained by this multi-dimensional pooling strategy are the result of the inclusion of each sample in multiple tests and the minimal overlap between pooled samples. A Bayesian inference framework in which the assessed probability of positivity for each sample is updated several times allows the algorithm to effectively distinguish between positive and negative samples (electronic supplementary material, figures S2 and S3), which in turn enables a non-adaptive methodology-i.e. reporting of outcomes for both positive and negative specimens in one testing round without the need for retesting. The experimental validation was performed manually, and thus the sample preparation burden was significant-setting up the individual tests was achieved in approximately 60 min versus approximately 210 min for their 48 pooled tests. While the actual sample preparation time is highly dependent on the user, it is clear that the additional effort precludes large-scale manual implementation. With regard to time to results, detailed accounting of the net efficiency gains will vary greatly not just because of sample preparation time, but will also depend on the test runtime and equipment modality (e.g. continuous sample loading versus batch processing). Importantly, because samples are pooled in predictable patterns and no post-screening sample retrieval is necessary, this protocol is compatible with automated sample processing (either bench-or laboratory-scale robotic liquid handlers). In fact, automation is critical for the long-term and high-volume implementation of this approach since it enables more complex versions (higher dimensionality and larger pool sizes) with larger efficiency gains and improved test performance, while eliminating human sources of error (e.g. cross-contamination) and reducing the additional burden of sample preparation. Finally, it is important to consider the analysis of results and output generation. Upon implementation, the routine analysis of results requires no user input and can be automated; however, appropriate steps must be taken to interface its output into a format compatible with clinical laboratory information systems. Importantly, individual sample reports could be enhanced with a continuous variable-the posterior probability-and its interpretation. To date, screening approaches based on pooling have found applications where efficiency in material resources is prioritized, but time is seldom a variable of interest, e.g. screening at blood banks. When applied at the population level (e.g. periodic prevalence monitoring), they are rarely expected to be deployed for an extended period of time or beyond a local scale. Thus, algorithms that are computationally complex or that require multiple rounds of testing have been favoured because they yield substantial gains in metrics such as samples screened per test used. However, as a result of the current SARS-CoV-2 pandemic, RT-PCR diagnostic testing has been carried out on large numbers of patients with sustained high demand-a situation that will likely intensify as communities worldwide move towards a reopening of economic activity and restrictions are lifted. Importantly, these testing efforts have a strong emphasis on quickly identifying positive cases in order to reduce community transmission-i.e. increasing the turnaround time for test results is not desirable. Additionally, the sensitivity and specificity characteristics of diagnostic tests are not perfect, and their availability may be limited. Under these novel constraints, pooled-sample screening protocols not only must increase sample throughput, but they should also minimize loss in sensitivity and maximize gains in specificity, while royalsocietypublishing.org/journal/rsif J. R. Soc. Interface 18: 20210155 avoiding increases in the sample processing time resulting from repeated storage, retrieval and testing steps. To address these limitations to scaling diagnostic testing for effective and sustained epidemiological surveillance at the population level in low-to-moderate prevalence groups, we propose a non-adaptive multi-dimensional pooling approach. Bayesian inference yields reportable outcomes at the individual specimen level in a single testing step with remarkable performance in a manner compatible with fully automated sample preparation and result interpretation. Considerable increases in sample throughput (greater than 2×) are achievable even at moderate prevalence rates (approx. 2%) without losses in test performance and without the need for multiple rounds of testing to reach individual-level outcomes for both positive and negative specimens. Accepting a moderate loss in screening sensitivity, in line with that of 1D pooling approaches, efficiency gains are larger and can be sustained at larger prevalence. With a combination of Monte Carlo simulations and a manual implementation with SARS-CoV-2 clinical samples, we demonstrate the viability of using this screening protocol in a real-world setting and contribute to solving the unprecedented challenges posed by the current SARS-CoV-2 pandemic. Data accessibility. All data are available in the main text or the supplementary materials. Code available via the online repository https://github.com/rnoriegam/bayesian-pooling. The data are provided in the electronic supplementary material. Responding to global infectious disease outbreaks: lessons from SARS on the role of risk perception, communication and management Epidemiology, transmission dynamics and control of SARS: the 2002-2003 epidemic Characterizing the epidemiology of the 2009 influenza A/H1N1 pandemic in Mexico Adaptive human behavior in epidemiological models Closure of schools during an influenza pandemic The effectiveness of contact tracing in emerging epidemics Optimizing spatial allocation of seasonal influenza vaccine under temporal constraints Presumed asymptomatic carrier transmission of COVID-19 What can early Canadian experience screening for COVID-19 teach us about how to prepare for a pandemic? COVID-19-new insights on a rapidly changing epidemic 2020 Countries test tactics in 'war' against COVID-19 2020 The reproductive number of COVID-19 is higher compared to SARS coronavirus New coronavirus outbreak: framing questions for pandemic prevention Group testing for severe acute respiratory syndromecoronavirus 2 to enable rapid scale-up of testing and real-time surveillance of incidence Large-scale implementation of pooled RNA extraction and RT-PCR for SARS-CoV-2 detection Ad hoc laboratorybased surveillance of SARS-CoV-2 by real-time RT-PCR using minipools of RNA prepared from routine respiratory samples Sample pooling as a strategy to detect community transmission of SARS-CoV-2 Evaluation of COVID-19 RT-qPCR test in multisample pools Assessment of specimen pooling to conserve SARS CoV-2 testing resources 2021 A nonadaptive combinatorial group testing strategy to facilitate health care worker screening during the severe acute respiratory syndrome coronavirus The detection of defective members of large populations Detection of acute infections during HIV testing in North Carolina Optimizing screening for acute human immunodeficiency virus infection with pooled nucleic acid amplification tests Utility of pooled urine specimens for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in men attending public sexually transmitted infection clinics in Mumbai, India, by PCR Pooling nasopharyngeal/throat swab specimens to increase testing capacity for influenza viruses by PCR Estimating the prevalence of multiple diseases from two-stage hierarchical pooling Adaptive Bayesian group testing: algorithms and performance. Signal. Process Theoretical analysis of library screening using a N-dimensional pooling strategy A new pooling strategy for high-throughput screening: the shifted transversal design 2020 Rapid, large-scale, and effective detection of COVID-19 via non-adaptive testing Efficient pooling designs for library screening Non-adaptive group testing in the presence of errors Interpretation of pooling experiments using the Markov chain Monte Carlo method Assessment of diagnostic technology in health care: rationale, methods, problems, and directions: monograph of the Council on Health Care Technology Diagnostic decision: probability theory in the use of diagnostic tests: an introduction to critical study of the literature Reasoning foundations of medical diagnosis: symbolic logic, probability, and value theory aid our understanding of how physicians reason US Food and Drug Administration Center for Devices and Radiological Health. 2020 Molecular Diagnostic Template for Laboratories. Policy for Coronavirus Disease-2019 Tests During the Public Health Emergency (Revised) US Food and Drug Administration Center for Devices and Radiological Health SARS-CoV-2 Assay (Panther Fusion® System) Acknowledgements. We thank Jonia Cook for assistance with specimen retrieval and the members of ARUP's Molecular Infectious Disease Laboratories for performing the Hologic testing. The views expressed in this article are those of the authors and do not necessarily reflect the position or policy of the Department of Veterans Affairs or the US government.