key: cord-0731580-5zezvjun authors: Hardikar, Mukta; Ikner, Luisa A.; Felix, Varinia; Presson, Luke K.; Rabe, Andrew B.; Hickenbottom, Kerri L.; Achilli, Andrea title: Membrane Distillation Provides a Dual Barrier for Coronavirus and Bacteriophage Removal date: 2021-07-14 journal: Environ Sci Technol Lett DOI: 10.1021/acs.estlett.1c00483 sha: b3e6105e6fa11dcf3ff89d8295baff63a6b677c2 doc_id: 731580 cord_uid: 5zezvjun [Image: see text] The persistence of pathogenic microorganisms in treated wastewater effluent makes disinfection crucial to achieve wastewater reuse. Membrane processes such as ultrafiltration and reverse osmosis (RO) have shown promising results for virus and other contaminant removal from treated wastewater effluents for reuse application. However, RO produces a concentrate stream which contains high concentrations of pathogens and contaminants that often requires treatment and volume reduction before disposal. Membrane distillation (MD) is a treatment process that can reduce RO concentrate volume while augmenting the potable water supply. MD is also a dual barrier approach for virus removal as it operates at a high temperature and permeates only the vapor phase through the membrane interface. The effects of temperature on viable virus concentration and membrane rejection of viruses in MD are investigated in this study using two nonenveloped phages frequently used as enteric virus surrogates (MS2 and PhiX174) and an enveloped pathogenic virus (HCoV-229E). At typical MD operating temperatures (greater than 65 °C), viable concentrations of all three viruses were reduced by thermal inactivation by more than 6-log(10) for MS2 and PhiX174 and more than 3-log(10) for HCoV-229E. Also, membrane rejection was greater than 6-log(10) for MS2 and PhiX174 and greater than 2.5-log(10) for HCoV-229E. Membrane distillation (MD) is a thermally driven membrane process that uses a temperature/vapor pressure gradient across a hydrophobic membrane as the driving force for transport of water vapor from an impure feed stream to a distillate stream. 1 While reverse osmosis (RO) is a proven technology to produce high quality water from wastewater treatment effluent for water reuse applications, the cost and environmental impact of RO concentrate disposal is still a major process challenge. 2,3 RO concentrate from water reuse applications contains high levels of salts, organics, and fecal-associated protozoa, bacteria, and viruses that are present in the input wastewater effluent. 4 MD is considered a viable process to recover water from RO concentrate and reduce the volume of RO concentrate to be disposed. 5−9 However, for water reuse applications, virus removal/rejection by the MD process must also be quantified. The removal of pathogenic viruses from wastewater streams by way of membrane rejection has been studied most commonly using MS2, a U.S. EPA-recommended enteric virus surrogate. 10 Similar in size to human enteric viruses (20− 30 nm), MS2 is characterized by a low isoelectric point (pI = 3.9) and therefore demonstrates a net negative surface charge in aqueous systems. MS2 is nonenveloped as are the most common human fecal-associated viruses found in wastewater (including reoviruses, enteroviruses, adenoviruses, and noroviruses). It has most often been described as hydrophobic and therefore more likely to adhere to hydrophobic membranes employed in RO and MD processes. 11, 12 Other bacteriophages have been studied to assess the efficacy of membrane rejection processes, although less frequently than MS2. 13 PhiX174 is a somatic coliphage with a higher pI of 6.6 and similarly exhibits a net negative surface charge in wastewater and treated effluents. 14 PhiX174 is also a nonenveloped virus but is more hydrophilic than MS2 and therefore less likely to adsorb to hydrophobic membranes. Both phages are nonpathogenic to humans and readily assayed, with quantitative infectivity results provided within 24 hours. 15 The use of these two surrogates provides a holistic understanding of nonenveloped virus removal using MD given varying surface characteristics. Wastewater studies conducted during the COVID-19 pandemic have revealed that ample levels of SARS-CoV-2, an enveloped virus, are shed in feces of infected individuals and are quantifiable in raw wastewater using molecular techniques. 16 Infectious human coronaviruses can also remain viable in wastewater over extended periods of time. 17 Therefore, the membrane rejection of enveloped viruses was also tested using human coronavirus 229E (HCoV-229E) as a surrogate for SARS-CoV-2. An isoelectric point range of 4.9−6.1 for several coronaviruses was recently calculated based on the genetic sequences of the spike protein. 18 The membrane glycoprotein (M) of coronaviruses is the most abundant of the structural proteins and is also highly hydrophobic. 19 Although coronaviruses as whole-virus particles have not been described as hydrophobic, it is surmised for this study that the surface characteristics described herein impart this trait. Therefore, the membrane rejection of HCoV-229E spiked into a concentrated wastewater stream was also investigated using MD. In conventional membrane processes such as RO or nanofiltration (NF), virus rejection is achieved by size exclusion and is thus dependent on membrane integrity for complete rejection. 20 In MD, the high operating temperature can reduce virus concentration in the feed and provide an additional barrier in the event of membrane damage. Additionally, as only the vapor phase permeates through the hydrophobic membrane, MD can theoretically reject 100% of nonvolatile solutes in the absence of pore wetting. However, recent studies have observed the transport of nonvolatile hydrophobic compounds even through nonwetted pores via hydrophobic interactions with the membrane. 21, 22 Therefore, it is important to investigate the rejection of viruses that are characterized by varying degrees of hydrophobicity. The objective of this study is to evaluate MD as a dual barrier process for virus reduction in the feed and removal from the distillate. Two nonenveloped bacteriophages (MS2 and PhiX174) and an enveloped viral pathogen (HCoV-229E) were selected for virus rejection tests. Bench-top studies were conducted to decouple the effects of feed temperature and membrane rejection of viruses and identify test conditions (i.e., water matrix and temperature) that impact infectious virus concentrations. Bench-scale MD tests were performed to quantify the membrane rejection of the three viruses. Propagation of Viral Stocks and Assay of Water Samples. All viruses, host bacteria, and cell lines used in the study were procured from the American Type Culture Collection (ATCC, Manassas, Virginia). Stocks of MS2 (ATCC 15597-B1) and PhiX174 (ATCC 13706-B1) were prepared separately using the double layer agar technique with log-phase host cultures ofEscherichia coli. HCoV-229E (ATCC VR-740) was propagated using the MRC-5 cell line (ATCC CCL-171). Water samples collected during testing were filtered (0.22 μm) and processed immediately. For the phages, distillate tank samples (220 mL) were assayed using the single agar layer technique by combining 100 mL of distillate with 100 mL of 2X TSA and 10 mL of the respective bacterial host. Distillate samples (210 mL) for HCoV-229E were concentrated using Centricon Plus-70 centrifugal filter units (EMD Millipore), and equivalent distillate volumes of 50 and 20 mL were assayed in triplicate. Details of propagation methods and virus assays are included in the Supporting Information (Section S1). Bench-Top Temperature Sensitivity Tests. MS2 and PhiX174 bacteriophages were spiked (2.5 × 10 6 PFU/mL) into four flasks containing 1 L of the test solution at room temperature and mixed for 15 minutes on stir plates before being placed in water baths at three different temperatures (45, 55, 65°C) with a room temperature control (25°C). RO concentrate with antiscalant was selected as the test solution as it represents the target water to be treated using MD and contains a complex mixture of dissolved salts, organic compounds, and antiscalant, 23 which may affect membrane rejection of the virus. 24,25 MS2 and PhiX174 stability in RO concentrate with antiscalant was also confirmed in preliminary water matrix tests (Sections S2 and S3). Samples (20 mL) were collected every hour and assayed as previously described to measure levels of infectious viruses. At 45°C, the bacteriophage concentration reduction was approximately 2log 10 over 4 hours; therefore, 40°C was selected as the feed solution temperature in subsequent MD rejection tests. Bench-Scale MD Tests. Membrane rejection tests were conducted in a direct contact MD configuration using a hydrophobic polytetrafluoroethylene (PTFE) membrane (Clarcor QL822, Parker Hannifin, Lee's Summit, MO) with a polypropylene (PP) support layer, 70%−85% porosity, and nominal pore size of 0.45 μm for all tests. Details of the benchscale system are available in the Supporting Information (Section S4). Virus rejection tests were conducted with both a Na 2 SO 4 solution (1.3 g/L in tap water, conductivity ∼2.4 mS/ cm) and RO concentrate with antiscalant as the feed solution and ultrapure water as the distillate. The feed solution was inoculated with MS2 and PhiX174 (2.5 × 10 6 PFU/mL) at room temperature and allowed to mix for 15 minutes in recirculation (bypassing the membrane), upon which samples were collected from the feed and distillate tanks. The feed solution was then heated to 40°C, and the distillate was cooled to 10°C. Both solutions flowed through the MD module in counter-current directions at 1 L/min resulting in a water flux of approximately 17 L/m 2 h. An additional volume of feed solution (1 L) was concurrently spiked and kept as the control at room temperature for the duration of each experiment. Samples were collected hourly from the control, feed, and distillate tanks to monitor concentrations of Na + (ICP-MS) and levels of infectious MS2 and PhiX174 in the water. For tests with RO concentrate as the feed solution, the total organic carbon (TOC) was measured, and size exclusion chromatography (SEC) analysis was performed for the feed and distillate. Details of the sample preparation for ICP-MS and TOC analyses can be found in the Supporting Information (Section S5). Bench-scale MD membrane rejection tests with RO concentrate with antiscalant as the feed solution were also conducted with HCoV-229E to test the rejection of enveloped viruses. Virus rejection and removal was calculated using: 26, 27 where V Di-1 and V Di are the volume of water in the distillate tank at two time points (i-1) and (i), C Di-1 and C Di are the analyte concentrations measured in the distillate at the two time points, and C F is the average concentration of the feed side between the two time points. 28 Both viruses showed reduced activity with increasing temperatures (Figure 1 ). At 45°C, after the initial decrease in the first hour, both virus concentration reductions were approximately 2-log 10 in 3 hours. At 55°C, viable MS2 concentrations reduced by more than 4-log 10 , and PhiX174 concentrations reduced by more than 2-log 10 during the test period. The benchtop temperature sensitivity tests demonstrate that, for the surrogate viruses tested, MD operating temperatures (>65°C) alone reduce infectious virus levels in the feed solution by more than 6-log 10 within 4 hours. The log reduction results correspond with data reported in the literature where a rapid decline in MS2 and PhiX174 concentrations has been observed at temperatures higher than 50°C. 29−32 Thus, the high operating temperature on the feed side provides the first barrier for virus removal in the concentrated stream of the MD treatment process. Membrane rejection tests were therefore performed at 40°C in the study described herein to maximize virus concentration in the feed and accurately measure virus rejection. Bench-Scale MD Tests: Synthetic Solution. Na 2 SO 4 was used to simulate a high conductivity feed solution and assess membrane integrity during virus rejection tests. The log rejection and MS2 and PhiX174 concentrations in the control, feed, and distillate for two replicate tests are shown in Figure 2 . While no MS2 was detected in the distillate (Figure 2a) , PhiX174 was detected after 1 hour (Figure 2b ) in one of the replicate tests. As MS2 is more hydrophobic than PhiX174, it could have been preferentially adsorbed to the active surface of the membrane via hydrophobic−hydrophobic interactions and been retained in the feed side. The selection of virus and viral properties is thus important in MD rejection tests. For MS2, the reduction in log rejection (>8-log 10 to 4.5-log 10 ) was because the feed virus concentration decreased during the experiment. Although there was permeation of PhiX174, more than 6-log 10 rejection was observed. It is also interesting to note that while PhiX174 permeation was detected, the Na + ion concentration in the distillate did not increase, and the distillate conductivity remained below 2 μS/cm (data not shown). The Na + ion log rejection was lower than the virus log PhiX174 concentration in the feed and control remained relatively constant throughout the test but PhiX174 permeated to the distillate in one replicate test. The log rejection values for Na + ions remained relatively constant throughout the test. However, relative to the virus, the low Na + ion concentrationand the Na + ion detection limit (0.125 mg/L) in the distillate, restricted the maximum recordable rejection. rejection because relative to the virus concentration in the feed solution, the Na + ion concentration was lower. Additionally, the Na + ion detection limit (0.125 mg/L) restricted the maximum recordable rejection. The difference in the replicate experiments suggests variability among membrane coupons that is otherwise unnoticed when performing less sensitive salt rejection tests. Bench-Scale MD Tests: RO Concentrate. The log rejection and MS2 and PhiX174 concentrations in the control, feed, and distillate for two replicate tests using RO concentrate with antiscalant as the feed solution are shown in Figure 3 . Only PhiX174 was detected in the distillate after 3 hours in one of the replicate tests. Further, the SEC analysis of the distillate indicated the permeation of low molecular weight organic compounds ( Figure S4 ). The high virus and Na + ion rejection suggests that pore flow is not responsible for organic transport. Other possible mechanisms like membrane sorption/desorption 35 or volatilization could potentially explain the transport of organic compounds into the distillate. 33, 34 . Membrane integrity was further verified by performing a high feed concentration Na + ion rejection test. A Na + ion rejection of more than 5-log 10 was observed (Table S3 ) which is more than the minimum PhiX174 rejection (4log 10 ). The high Na + ion rejection confirmed the absence of pore flow and suggests the transport mechanism of PhiX174 through the membrane may be attributed to membrane interactions. Overall, MD membranes achieved up to 8-log 10 bench-scale test with RO concentrate as the feed solution, ultrapure water as the distillate, and a control volume RO concentrate spiked with HCoV-229E at 25°C. The detection limit for the virus concentration was 1 MPN/50 mL (dashed line) in the distillate and 50 MPN/ 50 mL (dashed bar) in the feed solution. The feed temperature was gradually increased everyhour from 25 to 60°C to observe the effect of temperature on the virus concentration. The corresponding distillate temperature increased from 7 to 25°C, and the water flux increased from 5 to 20 L/m 2 h throughout the test. No permeation of HCoV-229E to the distillate was detected, and no virus was detected in the feed solution once the temperature reached 50°C. (b) Samples of RO concentrate spiked with HCoV-229E were placed in water baths at constant temperatures and showed 2-log 10 reduction in virus concentration at 40°C after 5 hours and were below the detection limit (indicated by arrows) at 50°C after the first hour. Environmental Science & Technology Letters pubs.acs.org/journal/estlcu Letter rejection of the bacteriophage viruses while treating concentrated wastewater. In the bench-scale MD rejection test with HCoV-229E, the feed temperature was increased over time while monitoring virus rejection. An average virus rejection of 2.48-log 10 was achieved, and no HCoV-229E was detected in the distillate (Figure 4a ). The HCoV-229E concentration in the feed solution decreased with increasing temperature, and there was no detectable virus in the feed solution over 50°C. The effect of temperature on HCoV-229E concentration over time was confirmed by placing RO concentrate volumes spiked with HCoV-229E into water baths at constant elevated temperatures (Figure 4b) . Temperature has been shown to denature proteins and inactivate enzymes, which can cause a decrease in viable virus concentration in the heated feed solution. 36 The high rejection of viruses and viral inactivation at elevated temperatures demonstrate that MD is well suited for the treatment of enveloped viruses. More importantly, in the case of membrane failure, MD provides a safeguard via thermal inactivation for operating temperatures over 50°C, thus ensuring high virus removal. The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acs.estlett.1c00483. Additional details of viral propagation, schematic of experimental setup, results of virus stability in test water matrices, and sample analysis (PDF) Emerging Investigator Series: Membrane Distillation and High Salinity: Analysis and Implications State-ofthe-Art of Reverse Osmosis Desalination Progress in Polymer Science A Review of Polymeric Membranes and Processes for Potable Water Reuse Reverse Osmosis Concentrate: An Essential Link for Closing Loop of Municipal Wastewater Reclamation towards Urban Sustainability Membrane Distillation at the Water-Energy Nexus: Limits, Opportunities, and Challenges Development of Simultaneous Membrane Distillation-Crystallization (SMDC) Technology for Treatment of Saturated Brine Optimization of Operating Conditions for a Continuous Membrane Distillation Crystallization Process with Zero Salty Water Discharge A Study of Membrane Distillation and Crystallization for Lithium Recovery from High-Concentrated Aqueous Solutions Adham, S. Field Evaluation of Membrane Distillation Technologies for Desalination of Highly Saline Brines Environmental Microbiology Mechanisms of Virus Removal from Secondary Wastewater Effluent by Low Pressure Membrane Filtration Role of Hydrophobic and Electrostatic Interactions for Initial Enteric Virus Retention by MF Membranes The Roles of Bacteriophages in Membrane-Based Water and Wastewater Treatment Processes: A Review Isoelectric Points of Viruses An Evaluation of Virus Removal Mechanisms by Ultrafiltration Membranes Using MS2 and Φx174 Bacteriophage Persistence of SARS-CoV-2 in Water and Wastewater Survival of Coronaviruses in Water and Wastewater Safe and Effective Disinfection of Showcave Infrastructure in a Time of COVID-19 The Coronavirus Membrane Glycoprotein Removal Efficiency and Integrity Monitoring Techniques for Virus Removal by Membrane Processes Fouling and Crystallisation Behaviour of Superhydrophobic Nano-Composite PVDF Membranes in Direct Contact Membrane Distillation Contaminant Rejection in the Presence of Humic Acid by Membrane Distillation for Surface Water Treatment Increasing Water Recovery during Reclamation of Treated Municipal Wastewater Using Bipolar Membrane Electrodialysis and Fluidized Bed Crystallization Removal of Viruses by Microfiltration Membranes at Different Solution Environments Integrating an Aerobic/Anoxic Osmotic Membrane Bioreactor with Membrane Distillation for Potable Reuse Membrane Distillation for Concentration of Hypersaline Brines from the Great Salt Lake: Effects of Scaling and Fouling on Performance, Efficiency, and Salt Rejection Effect of Temperature, PH, and NaCl on the Inactivation Kinetics of Murine Norovirus Effects of PH and Temperature on the Survival of Coliphages MS2 and Qβ Viruses by Heating Steps Applied during Manufacture of a Hepatitis B Vaccine The Impact of Temperature on the Inactivation of Enteric Viruses in Food and Water: A Review Modeling the Concentration of Volatile and Semivolatile Contaminants in Direct Contact Membrane Distillation (DCMD) Product Water Evaluation of Semi-Volatile Contaminant Transport in a Novel, Gas-Tight Direct Contact Membrane Distillation System Diffusion Behavior of Humic Acid during Desalination with Air Gap and Water Gap Membrane Distillation Review of Factors Affecting Microbial Survival in Groundwater