key: cord-0729437-meufijht authors: He, Congrong; Mackay, Ian M.; Ramsay, Kay; Liang, Zhen; Kidd, Timothy; Knibbs, Luke D.; Johnson, Graham; McNeale, Donna; Stockwell, Rebecca; Coulthard, Mark G.; Long, Debbie A.; Williams, Tara J.; Duchaine, Caroline; Smith, Natalie; Wainwright, Claire; Morawska, Lidia title: Particle and bioaerosol characteristics in a paediatric intensive care unit date: 2017-10-31 journal: Environment International DOI: 10.1016/j.envint.2017.06.020 sha: 16704e9a2b5bcfd1ce150f52e6b8f5ed5cfb927c doc_id: 729437 cord_uid: meufijht Abstract The paediatric intensive care unit (PICU) provides care to critically ill neonates, infants and children. These patients are vulnerable and susceptible to the environment surrounding them, yet there is little information available on indoor air quality and factors affecting it within a PICU. To address this gap in knowledge we conducted continuous indoor and outdoor airborne particle concentration measurements over a two-week period at the Royal Children's Hospital PICU in Brisbane, Australia, and we also collected 82 bioaerosol samples to test for the presence of bacterial and viral pathogens. Our results showed that both 24-hour average indoor particle mass (PM10) (0.6–2.2μgm−3, median: 0.9μgm−3) and submicrometer particle number (PN) (0.1–2.8×103 pcm−3, median: 0.67×103 pcm−3) concentrations were significantly lower (p<0.01) than the outdoor concentrations (6.7–10.2μgm−3, median: 8.0μgm−3 for PM10 and 12.1–22.2×103 pcm−3, median: 16.4×103 pcm−3 for PN). In general, we found that indoor particle concentrations in the PICU were mainly affected by indoor particle sources, with outdoor particles providing a negligible background. We identified strong indoor particle sources in the PICU, which occasionally increased indoor PN and PM10 concentrations from 0.1×103 to 100×103 pcm−3, and from 2μgm−3 to 70μgm−3, respectively. The most substantial indoor particle sources were nebulization therapy, tracheal suction and cleaning activities. The average PM10 and PN emission rates of nebulization therapy ranged from 1.29 to 7.41mgmin−1 and from 1.20 to 3.96pmin−1 ×1011, respectively. Based on multipoint measurement data, it was found that particles generated at each location could be quickly transported to other locations, even when originating from isolated single-bed rooms. The most commonly isolated bacterial genera from both primary and broth cultures were skin commensals while viruses were rarely identified. Based on the findings from the study, we developed a set of practical recommendations for PICU design, as well as for medical and cleaning staff to mitigate aerosol generation and transmission to minimize infection risk to PICU patients. Maintaining high levels of indoor air quality in hospitals is important for protecting both staff and patients (Jung et al., 2015) . The transmission of infectious diseases within hospitals poses a significant health risk and is of significant clinical concern (Cornejo- Juarez et al., 2015) . Despite the implementation of infection control policies, transmission of infections within hospitals continues to occur (Siegel et al., 2007; Assiri et al., 2013) . These transmissions could be patient-to-patient, visitor-to-patient, patient-to-health care worker and health care worker-to-patient. The available evidence about the airborne spread of infection is limited, although transmission has been described for tuberculosis, measles, chickenpox and pertussis and multidrug-resistant nontuberculous mycobacterium (Leclair et al., 1980; Bloch et al., 1985; Dharmadhikari et al., 2012; Warfel et al., 2012; Bryant et al., 2016) . Other studies have suggested opportunistic spread of influenza virus and respiratory syncytial virus (RSV) via an airborne route (Roy and Milton, 2004; Killingley and Nguyen-Van-Tam, 2013; Luongo et al., 2016; Kulkarni et al., 2016) . Further, Zingg et al. (2015) and Arefian et al. (2016) pointed out to the possibility of poor indoor air quality resulting in increased morbidity for health care workers, extended patient hospitalization as a result of hospital-acquired illnesses and also to increased economic costs. Typically, hospitalized patients are triaged according to illness and level of care required, with the most critical patients admitted to an intensive care unit (ICU). Critically ill neonates, infants and children are cared for separately within the paediatric intensive care unit (PICU) (Bennett and Bion, 1999) . A number of factors have been associated with increased risk of infection transmission among hospitalized patients. These include the increased number of airborne particles generated by activities such as suction, nebulization and cleaning especially at times when patient admissions are highest and when seasonal viruses are at their peak (Eidelman et al., 2009; Leung et al., 2014; WHO, 2014) . Parents, guardians, visitors and hospital staff who are shedding viruses also increase the risk of hospital-acquired infection and contribute to increased particle concentration (Voirin et al., 2009 ). The quality of the air supply within the PICU environment is also important, as airborne pollutant exposure may affect the health of staff and patients. Currently, only one study has been conducted to investigate indoor bioaerosol characteristics in the PICU (Li and Hou, 2003) . The aim of this study was to improve our knowledge of indoor airborne particle and bioaerosol characteristics in a PICU environment. The objectives were: (1) to measure indoor and outdoor particle number (PN) and particle mass (PM 10 ) concentrations for two weeks continuously and simultaneously; (2) to identify particle sources and estimate particle emission rates; (3) to assess the filtration efficiency of the building ventilation system filters; (4) to analyze the spatial distribution and variation of particle concentrations; and (5) to collect bioaerosol samples and identify examples of airborne bacteria or viruses. The main reasons for measuring particle concentrations and particle sizes are to understand the airborne particle size distribution and the type of airborne aerosol particle; identify the possible source of the particles; and assess their effect on human health. It is, however, important to note that this study did not seek to investigate or establish whether microbial transmission occurred between patients, or between patients and visitors. This study was conducted in a PICU at the Royal Children's Hospital, Brisbane, Australia. The floorplan of the PICU is shown in Fig. 1 . The PICU consisted of 8 beds, of which Bed 1 and Bed 2 were located in separate rooms, and the others were situated in a common area. The size of this PICU is approximately 231 m 2 . A nurses' station was located in the centre of the PICU. A mechanical air-handling unit (AHU) with two-stage filtration provided a constant flow of supply air to the PICU. The first stage filters (dry media filters) functioned in the same way as those in a typical mechanical ventilation system, with a filtration efficiency of 45-65%, while the second stage filters were high efficiency particulate air filters (HEPA) (Econocell Filters, Australia). There were four return air outlets, which were located above Beds 5 and 6, between Beds 5 and 6, and in the visiting room. In general, the first and second stage (HEPA) filters of the ventilation system were changed after approximately 1-2 years and 2-3 years, respectively. Indoor supermicrometer PN 0.5-20 μm concentration and size distribution (from 0.5 to 20 μm) were measured using a TSI Model 3312A Ultraviolet Aerodynamic Particle Sizer (UVAPS, TSI Incorporated, Shoreview, MN, USA), with a time resolution of 20 s. Indoor supermicrometer particle number PN 0.3-25 μm concentration and size distribution (from 0.3 to 25 μm) were measured using a TSI AeroTrak Handheld Particle Counter 9306 (OPC, TSI Incorporated). The two instruments provided information on indoor spatial variations of supermicrometer particle concentration. Indoor and outdoor total submicrometer PN 0.005-3 μm concentrations were measured using three TSI Model 3787 Condensation Particle Counters (CPC, TSI Incorporated) in the size range from 0.005 to 3 μm, and with a time resolution of 10 s (indoor) or 20 s (outdoor). Two of the instruments were operated indoors and one sampled outdoor air and was located next to the AHU outdoor air intake. One TSI Model 3007 CPC and one TSI P-Track were used for short-term (daytime) indoor total submicrometer PN 0.01-1 μm and PN 0.02-1 μm measurements, respectively. 2.2.2. Particle mass (PM 10 ) concentration (mass concentration of particles with an aerodynamic diameter smaller than 10 μm) Indoor and outdoor PM 10 concentrations were simultaneously measured by a TSI DustTrak-DRX and a TSI DustTrak II, respectively. Given that this work focused on an area with multiple potential sources of particles, including sources of particles larger than 2.5 μm (e.g. human-generated aerosols, resuspension etc.), it was appropriate to measure particle mass concentrations in terms of PM 10 , rather than PM 2.5 . Indoor bioaerosol samples were collected using a Coriolis μ Air Sampler (Bertin Technologies, France). Each sample, consisting of 3 m 3 of air collected at 0.3 m 3 per minute, was drawn into a conical sterile tube containing 15 ml of saline solution (0.85% NaCl). Normal saline or 0.9% sodium chloride is not mandatory, but is the preferred solution for bacterial manipulations as it is an isotonic solution and therefore the osmotic pressure of the bacterial cells is maintained. Saline is also a suitable medium to retain viral integrity prior to nucleic acid extraction for PCR. Due to the high flow rate used for sampling, it was possible that some of the liquid became aerosolized during sample collection. To contain these particles and prevent them from being released into the indoor air of the PICU, the instrument was placed in a plastic bag, with a HEPA filter at its outlet to remove any particles generated by the Coriolis μ Air Sampler. Time series of indoor and outdoor CO 2 , temperature and relative humidity were measured by a TSI Q-Traks (TSI 7545). Supply and return air velocities were monitored using a TSI Model 8330 anemometer (VelociCalc) and a TSI Model 8705 DP-Calc Micromanometer, respectively. All instruments were tested and calibrated in the laboratory prior to the PICU measurements, and co-located comparative tests for all particle instruments were conducted simultaneously during the last day of the measurements. Data on local outdoor PM 10 concentrations and meteorological parameters were collected from a nearby regulatory air quality monitoring station (5 km away), and an Australian Bureau of Meteorology weather station located in Brisbane (10 km away), respectively. De-identified nasal swabs were collected twice (PICU-inbound and PICU-outbound) between 8:00 am and 5:00 pm from each consenting adult who visited the PICU on a single day. One nostril was swabbed with a sterile swab, which was placed in a sterile saline solution, then the vial capped and sent to the laboratory for storage and batch processing. In total, 152 swabs were collected. The detection rate for the primary cultures is 46% and 8% pathogens. This study was conducted in the PICU from 4 to 16 August 2014, which was during the peak influenza season in Brisbane, and when hospital admissions were high. Continuous indoor measurements were conducted using two sets of instruments. One set (including the UVAPS, CPC 3787 and DustTrak) was located in the center of the PICU throughout the entire measurement campaign. To determine indoor particle transport and dispersion, the second set of instruments (including the OPC and CPC 3787) was moved among a variety of locations throughout the entire measurement campaign, and the measurements at each location were conducted for at least 24 h. Additionally, the hand-held TSI P-Track and/or Model 3007 CPC were added for short-term (daytime 8 h) indoor total submicrometer PN measurements at several locations within the ward. Thus, there were three or four places where indoor total submicrometer PN measurements took place simultaneously. Continuous outdoor measurements were conducted using the third set of instruments including a CPC 3787 and DustTrak, which were located in the plant room throughout the entire measurement period. Supply air PN concentrations were measured for approximately 15 min at each of the air outlets (total of 15) of the PICU by the P-Track. The tests were conducted at five points: one in the center (C1, C2, C3, C4 and C5), and one along each of the four sides of the outlet (S1 to S4) of each outlet. The tests were conducted once a day on several different days of the measurement campaign. Overnight supply air PN concentration monitoring was conducted using a CPC 3787 at two outlets, on two occasions throughout the monitoring period. Supply air velocities were measured at each outlet using the VelociCalc. The measurement method was the same as for supply air PN concentrations. Overnight supply velocities were continuously monitored by the DP-Calc at two outlets for > 24 h. The filtration efficiencies of the two-stage filters were tested by using two CPCs and two DustTraks. In all cases, one bioaerosol sample was collected at the center of the PICU, followed by samples collected 1 m from each patient bed (when possible), and then one final sample from the center location. This sampling process was conducted twice a day during the daytime (8:00-17:00). One sample was collected in the morning and one was collected in the afternoon; thus two samples were collected daily from each patient bed space. Nasal swab samples were collected on one of the sampling days. For each patient being cared for in the PICU during the study, deidentified clinical data were reviewed to confirm the presence or absence of a current respiratory infection. The number of patients and people in the PICU was recorded by observation every 2 h throughout each day (from 7:00 am to 6:00 pm). We paid particular attention to recording when and where aerosol-generating clinical activities, such as C. He et al. Environment International 107 (2017) The biological samples were analyzed to characterize their bacterial and viral content. Following collection of a bioaerosol sample using the Coriolis μ Air Sampler, the saline collection was processed using two methods (primary sampling and broth cultures) to isolate potential bacterial pathogens. Processing of the primary sample was as follows. A 0.1 ml aliquot of the neat saline collections was subcultured directly onto a blood agar plate (Thermo Scientific, Australia) and a MacConkey agar plate supplemented with crystal violet (Thermo Scientific, Australia) and incubated for a total of 72 h at 37°C, under 5% CO 2 and 0% CO 2 atmospheres, respectively. The broth culture was processed using a 1 ml aliquot of the sample that was centrifuged at 14,000 rpm for 2 min. The supernatant was discarded and the pellet was resuspended in 2 ml of Luria Bertani Broth (Oxoid Ltd., Australia) and incubated overnight in a 0% CO 2 atmosphere. Following the incubation period, 0.1 ml of the sample was subcultured onto a blood agar plate and a MacConkey agar plate supplemented with crystal violet and incubated for a total of 72 h under 5% CO 2 and 0% CO 2 atmospheres, respectively. All agar plates were reviewed daily for growth of bacterial pathogens. Phenotypic tests, including morphology, gram stain, oxidase (Becton, Dickinson and Company) and Staphytect Plus (Oxoid Ltd., Australia) latex agglutination test were used to determine if the isolate would be considered a pathogen or a skin commensal. All presumptive pathogens were stored in 15% glycerol in a − 80°C freezer. The presumptive bacterial pathogens were subcultured from the freezer onto blood agar plates prior to identification using the Vitek® MS Mass Spectrometry MALDI-TOF instrument (bioMerieux Pty Ltd., Australia). Total nucleic acids were extracted from 0.2 ml of the impacted Coriolis liquid and from 0.2 ml of each of 152 swabs after each swab was resuspended by vortexing in 1 ml of OptiMEM® I (Gibco, Australia) medium, followed by purification using High Pure Viral Nucleic Acid spin columns (Roche Diagnostics, Australia) according to the manufacturer's instructions. Primary specimens and purified nucleic acid extracts were stored at −70°C. Extracts (2 μl) were tested by RT-PCR (SensiFAST™ One-Step, Bioline, Australia) or PCR (MyTaq™ DNA Polymerase, Bioline, Australia), as appropriate for the viral genome. All swabs were assessed for a panel of respiratory viruses (influenza virus A and B, human adenoviruses, RSV, human metapneumovirus [HMPV], human parechoviruses and human rhinoviruses [HRVs]) using individual real-time RT-PCR as described previously by Chang et al. (2009 ), Arden et al. (2010 and Lu et al. (2008) . The rhinovirus assay was determined to have a dynamic range of 9 log 10 copies of in vitro transcribed HRV-16 genomic RNA and could reliably detect 4 copies per reaction volume (data not shown). Additional real-time RT-PCR testing for parainfluenza virus (HPIV) 1-3 (Chang et al., 2009 ) and human coronaviruses (HCoVs) (Mackay et al., 2012) was undertaken on the 60 nasal swabs. A housekeeping gene real-time RT-PCR assay targeting the human UBE2D2 gene was used on the nasal swab extracts to determine the presence of human cellular mRNA as a measure of successful swab sampling (Chiu et al., 2006) . All RT-PCRs consisted of a 20 min pre-cycling incubation at 45°C and a 2 min pre-cycling incubation at 94°C followed by 35 cycles of 94°C/5 s, 60°C/60 s. PCR cycling was preceded only by a 15-min incubation at 94°C followed by 35 cycles of 94°C/10 s, 60°C/60 s. When particle dynamics such as condensation, evaporation and coagulation are negligible, the main factors influencing indoor particle concentrations are emissions from indoor sources, penetration of outdoor particles, particle loss due to deposition on indoor surfaces, and air exchange rates (Morawska and Salthammer, 2003) . The equation which relates these parameters has been reported in our previous studies (He et al., 2004; Morawska et al., 2009; Quang et al., 2014) : where C in and C out are indoor and outdoor particle concentrations, respectively, P is the penetration efficiency, k is the deposition rate, α is the air exchange rate, Q s is the indoor particle generation rate, t is time and V is the effective volume of the space. For mechanical ventilation conditions, Eq. (1) can be modified to: where F is supply air flow rate, and C supply is supply air particle concentration. The average emission rate, Q s , can therefore be estimated by using average parameters and the following equation: where C int and C in0 are the peak and initial indoor particle concentrations, respectively, − C in is the average indoor particle concentration;− + α k ( )is the average total removal rate (which can be calculated using average decay rate after the source ceased operating), − α is the average air exchange rate, and Δ T is time difference between the initial and peak concentrations. Data from the online particle measurements were grouped according to their location and time period. The total 24 h average indoor and outdoor concentrations were calculated for each indoor location, and used to determine the indoor/outdoor (I/O) concentration ratios. All statistical analyses (t-tests) were conducted using SPSS for Windows version 10 (SPSS Inc.). A 5% level of significance (two-tailed) was used in all analyses. During the measurement period, the PICU operated as normal. The average number of people in the PICU was 13.4 with a maximum of 26 (12:00 pm) and a minimum of 5 (8:00 am) (see Supporting Information Fig. S1 ). The overall average 24 h indoor PM 10 , PN 0.005-3 μm and PN 0.5-20 μm concentrations were 1.1 ± 0.5 μg m − 3 , 0.93 ± 0.94 × 10 3 p cm − 3 , and 0.13 ± 0.09 p cm − 3 , respectively. Daily 24 h average indoor and outdoor PM 10 and PN 0.005-3 μm concentrations are presented in Fig. 2 . Both the average indoor PM 10 (0.6-2.2 μg m − 3 , median: 0.9 μg m − 3 ) and PN 0.005-3 μm (0.1-2.8 × 10 3 p cm − 3 , median: 0.67 × 10 3 p cm − 3 ) concentrations were significantly lower (p < 0.01) than the outdoor concentrations (6.7-10.2 μg m − 3 , median: 8.0 μg m − 3 for PM 10 and 12.1-22.2 × 10 3 p cm − 3 , median: 16.4 × 10 3 p cm − 3 for PN 0.005-3 μm ). The daily 24 h average outdoor PM 10 concentrations measured at the hospital were comparable with those at the nearby monitoring station during the measurement period (Fig. S2 ). The I/O ratio ranged from 0.07 to 0.26, with a median value of 0.11 for PM 10 , and from 0.01 to 0.19, with a median value of 0.04 for PN 0.005-3 μm , respectively. Therefore, the 24 h indoor concentrations were only about 11% and 4% of the 24 h outdoor PM 10 and PN 0.005-3 μm concentrations, respectively. It can also be seen from Fig. 2 that the 24 h indoor concentrations varied from day to day for both PM 10 and PN 0.005-3 μm , but particularly for PN 0.005-3 μm . Similar variation was seen in the 24 h average indoor supermicrometer PN 0.5-20 μm concentrations, with a range of 0.052 p cm − 3 to 0.376 p cm − 3 and a median of 0.095 p cm − 3 (Fig. S3 ). Based on daily 24 h average indoor and outdoor concentration data, the relationships between indoor and outdoor concentrations of both PM 10 and PN 0.005-3 μm were very weak (R 2 = 0.08), as were the relationships between diurnal variations of indoor and outdoor concentrations. This implies that indoor concentrations were mainly affected by indoor sources, and to a lesser extent by outdoor air. An example of the diurnal variation of indoor and outdoor concentrations is given in Fig. 3 , which shows that both indoor PM 10 and PN 0.005-3 μm concentrations increased due to nebulization therapy, cleaning activities and operation of other indoor sources. In general, however, when there were no indoor particle sources operating, indoor particle concentration, particularly of PN 0.005-3 μm , followed the trend of outdoor concentration. A summary of the average PN 0.02-1 μm concentrations of supply air measured at each outlet is presented in Fig. 4 (the location of each supply air outlet is shown in Fig. 1) , showing that the concentrations varied significantly between outlets. All the results for the average PN 0.02-1 μm concentrations at each of the five points of the outlet supply air measurements are shown in Table 1 . The highest average PN 0.02-1 μm concentration of supply air was found at the SR (store room) outlet, which was likely due to lack of a HEPA filter. The second highest concentration was found at the C1 (center 1) outlet. Notably, the PN 0.02-1 μm concentrations at S1 and S3 were about 20 times higher than those at C, S2 and S4, which indicates that there may have been leaks on side 1 and side 3 of the C1 supply air outlet. The overall average PN 0.02-1 μm concentration of the supply air ranged from 1.9 p cm − 3 to 329 p cm − 3 , with a median value of 20.6 p cm − 3 and average value of 50 ± 99 p cm − 3 (excluding supply air PN 0.02-1 µm concentrations at SR). An example time series of outdoor and supply air (at Bed 7 outlet) PN 0.005-3 µm concentrations measured by two CPC 3787s is shown in Fig. 5 , highlighting that the concentrations followed the same pattern. However, the average PN concentration of the supply air (1 p cm − 3 ) was about 0.008% of that in outdoor air (12.2 × 10 3 p cm − 3 ). These results show that indoor particle concentrations in the PICU were C. He et al. Environment International 107 (2017) 89-99 mainly affected by indoor particle sources, with outdoor particles providing a negligible background. Based on the time series of indoor and outdoor PN concentrations, in combination with the clinical activity records, the most significant indoor particle sources were found to be nebulization therapy and cleaning activities. In addition, it was seen that invasive tracheal suctioning performed by nurses or medical staff might have been another important indoor particle source. It was not possible to link all the peaks in particle concentrations with the sources generating them, due to the lack of activity records, particularly during the night, or because they were simply not recognized or recorded. Fig. 6 shows an example of a time series of indoor and outdoor PN 0.005-3 μm and indoor PN 0.5-20 μm concentrations, as well as indoor and outdoor PN 0.005-3 μm and PM 10 concentrations in the PICU. From this figure, the effect of indoor sources on indoor particle concentrations can be seen, and in particular that there were many peaks in both supermicrometer and submicrometer particle concentrations, which suggests that there were different types of indoor particle sources. Some sources generated only supermicrometer particles (such as dusting, changing bed sheets, coughing), others generated only submicrometer particles (such as mopping the floor with detergent), while some produced both types of particles (such as nebulization therapy). A summary of the daily maximum peak concentrations is given in Fig. 7 , with the highest vales of 4.65 × 10 5 p cm − 3 , 14.7 p cm − 3 and 409 μg m 3 for submicrometer PN 0.005-3 μm , supermicrometer PN 0.5-20 μm and PM 10 , respectively. Analysis of the time series of indoor and outdoor particle concentrations combined with nebulization therapy activities and drug using records, identified nebulization of three drugs (salbutamol, ipratropium and adrenaline) as a source of indoor particle production. A summary of the estimated PM 10 , PN 0.005-3 μm and PN 0.5-20 μm emission rates during nebulization of these drugs, and the median peak concentrations, are presented in Table 2 , from which it can be seen that the highest emission rates are from nebulized salbutamol (PM 10 : 7.41 mg min − 1 ; PN 0.005-3 : 3.96 p min − 1 × 10 11 ; PN 0.5-20 : 6.39 p min − 1 × 10 8 ). The average and range of CO 2 concentration, temperature and relative humidity in the PICU were 433 (404-837) ppm, 22.8 (21.2-24.3)°C and 47.3 (33.3-59.4) %, respectively. Based on particle concentrations in outdoor air and inside the ventilation duct, the average filtration efficiency of the primary filter of the air conditioning unit was estimated to be 57.5% and 40.0% for submicrometer PN and PM 10 , respectively. Based on particle concentrations in the ventilation duct and the supply air, the average filtration efficiency of the HEPA filter was estimated to be 99.98% for submicrometer PN. The overall filtration efficiency of the two-stage filters was 99.99%, which is close to the design value of 100%. C. He et al. Environment International 107 (2017) 89-99 The average velocity of the supply air varied between the outlets, and ranged from 0.5 m s − 1 to 1.4 m s − 1 , with an overall average of 1.0 ± 0.3 m s − 1 . The overall equivalent supply air flow rate was 5256 m 3 per hour and the estimated total mechanical air exchange rate was 10.8 h − 1 . These results provide evidence that the use of a twostage filter system in this hospital was very effective in supplying clean air into the PICU. The main return air outlet was located in the middle between Bed 5 and Bed 6, from which about 32% of all return air was returned. After noting PN concentration peaks associated with presumed secondary particle formation following floor cleaning with detergent, we recognized that we were able to use it as an opportunistic tracer of air movement within the PICU. Thus, the particle transport patterns in the PICU were assessed serendipitously by conducting simultaneous multi-location measurements of indoor submicrometer particle concentrations generated by the cleaning detergent. The results showed that: 1) particles generated at all the beds, except Bed 1, could be transported across the whole center; 2) particles generated at any of the center locations could also be transported to all beds, except Bed 1 and 3) particles generated at any bed could be transported to other beds, except Bed 1 and 4) the concentration of transported particles was dependent on the distance between the two locations; however, particles generated at any bed, except Bed 1 and 2, were more easily transported to the center location. Examples of the particle concentration time series used to determine particle transport are given in Figs. 8, 9 and 10. Eighty-two samples were processed for bacterial testing. Forty-nine samples were culture negative following processing of the primary sample and of these, only 18 remained sterile at the completion of the broth culture method. The average bacteria concentration was < 13 CFU m − 3 . The most commonly isolated bacterial genus from both the primary and broth cultures were those referred to as skin commensals (Kong and Segre, 2012) , including coagulase-negative Staphylococcus (primary culture 45.5%, broth culture 64.9%), Micrococcus species (primary culture 30.3%, broth culture 21.1%) and Corynebacteria species (primary culture 9.1%, broth culture 7.0%) ( Table 3 ). Of the samples that were positive for bacterial growth in the primary culture, 69.7% grew the same organism in the broth culture, whereas only 40.4% of all culture positive broth cultures matched the growth from the primary cultures. Presumptive bacterial pathogens were isolated from a total of seven samples, including four samples collected from beds and three from the common walkway corridor within the PICU ward. Bacterial counts of the pathogens isolated from the primary sample collection were low (≤ 5 CFU ml − 1 ). Following identification using the MALDI-TOF, pathogens were confirmed present in only three samples, with the remaining four being confirmed as skin commensals (n = 2), Neisseria species (n = 1) and a non-viable culture. Pantoea dispersa was isolated in the primary and broth cultures from Bed 3, and Staphylococcus aureus and Enterobacter cloacae were isolated from the primary cultures of the common walkway corridor and Bed 8, respectively (Table 4) . Extraction of nucleic acids from all the air sample aliquots was conducted and these were tested for rhinoviruses, because of their expected ubiquity. No samples were positive for any rhinovirus. Extraction of nucleic acids and testing for rhinoviruses, influenza Table 2 Peak concentration values (PV) and the estimated emission rates (ER) of PM 10 and PN 0.005-3 µm and PN 0.5-20 µm during nebulization therapy activities. Fig. 8 . Time series of indoor PN concentrations at two locations (Center and Bed 6), with particle source information (at Bed 5 or Bed 7, respectively). C. He et al. Environment International 107 (2017) 89-99 viruses, adenoviruses, RSV, HMPV and parechoviruses on all PICUoutbound nasal swabs was performed. Testing for HCoVs and HPIVs was also performed for 60 nasal swabs. Viral RNA was detected in four swabs; swab#9 for HCoV-OC43, #11 and #12 for HMPV and #109 for HCoV-NL63. Higher levels of detection had been hypothesised, since even healthy people will occasionally have a virus detectable. We also tested the extracts for the presence of a human gene to ensure that: 1) we were getting cells in the swabs as a sign of a satisfactory swabbing of the nares; and 2) that our assay reagents were performing as expected. All swabs tested positive for human mRNA using the UBE2D2 assay. Additionally, our positive and negative viral controls in each run functioned within specifications. There were fewer swabs positive for a virus than we had expected, but all contained human cells as indicated by positive UBE2D2 RT-PCR results. We did not have the funds available to use virus concentrating columns. Their use may have yielded additional positives in air samples; however, the paucity of viruses among staff and visitors of patients suggests it would be unlikely. Over a two-week period we measured simultaneously and continuously the indoor and outdoor particle mass and number concentration of the PICU, Royal Children's Hospital, Brisbane, Australia. We also collected indoor bioaerosol samples to determine the presence of pathogens. The indoor concentration levels, both particle number and mass, in this PICU were significantly lower than those in any other indoor environments in Brisbane, which we measured (e.g. residential houses, office buildings, schools, child care centers), except the bone bank building Morawska et al., 2003; Quang et al., 2013; Morawska et al., 2009; Guo et al., 2010) . Partially due to the unique and sensitive nature of PICUs, only one study has reported both particle number and bioaerosol concentrations there. Li and Hou (2003) measured the time series of supply and room air total particles (particle size ranging from 0.1 to 5 μm) number concentrations during day time (08:00-18:00) for two days in a PICU in Taiwan. The study showed that the average supply air PN 0.1-5 μm . This implies that the average indoor PN 0.1-5 μm concentrations were about 3.4 times higher than those of supply air in that PICU. In our study the average indoor PN concentrations were about 17 times higher than those in supply air. However, it should be noted that it is difficult to compare the results from the two studies because of the different instruments used and the particle size range measured in the two studies. Recently, Licina et al. (2016) estimated indoor PM 10 concentrations in a neonatal intensive care unit (NICU) based on year-long particle number concentration measurements (0.3-10 μm, 6 size groups) in a private hospital in the USA. They found that the time-averaged PM 10 concentrations in the individual baby rooms were generally low, not exceeding 5 μg m − 3 (mean ± standard deviation = 2.9 ± 0.8 μg m − 3 ), which they attributed to efficient particle filtration, effective building hygiene protocols and relatively low occupancy. Tang et al. (2009) and Gaidajis and Angelakoglou (2014) measured PM 10 concentrations in ICUs in Taiwan and Greece, respectively. The average PM 10 concentration values in ICUs were 14 μg m − 3 in Taiwan and 59 μg m − 3 in Greece. In contrast, this study showed that the average PM 10 value (1.0 ± 0.5 μg m − 3 ) was significantly lower than the previous research in NICU or ICU environments. Li and Hou (2003) measured bioaerosol concentrations in the PICU and reported that the average concentrations of fungi and bacteria ranged from 13 to 259 CFU m − 3 (median: 41.5 CFU m − 3 ) and from 35 to 156 CFU m − 3 (median: 46.5 CFU m − 3 ), respectively. However, there was no clear information regarding the identity of the microorganisms detected. Bacteria concentrations (< 13 CFU m − 3 ) found in our study were lower than the values previously reported by Li and Hou (2003) . The results of this study show that nebulization therapy generated a large amount of submicrometer and supermicrometer particles, which were transported quickly within the PICU and led to substantial increases in the indoor PM 10 and PN levels. The moveable walls in the PICU may have partially aided in reducing particle transport between the beds, but not between the beds and the nurses station. There may be three mechanisms of particle generation during nebulization therapy: from the drug, the drug solution, and the patient's breathing. For example, Roberts et al. (2006) reported that the use of nebulisers appears to be associated with the production of particles < 3 μm and, more importantly, that the bioaerosol concentration significantly increased from approximately 70 to 1300 CFU m − 3 during nebulization therapy in an ICU in the UK. While nebulization of drugs is required to treat patients, due to the large production and efficient movement of particles within the PICU, it is prudent to consider whether it could lead to unintended exposures to these particles among other patients and staff. Similarly, other patients and staff in the PICU may also be unnecessarily exposed to particles generated from the nebulized drug solution. Furthermore, particles generated from patients' breathing could also be considered a risk to other patients and staff in the PICU, as they may contain harmful bacterial and viral pathogens. However, the potential risk of nebulization may be reduced within this PICU as no rhinoviruses were detected in any of the samples tested during this study, despite being considered common viruses even among those without symptoms. Based on the results, the following recommendations may be considered to mitigate aerosol generation and transmission: (1) for hospital designers: designing a better ventilation system or adding bed head removable return air inlets, which can be employed during nebulization therapy or when patients are coughing; (2) for managers and nurses: using screens or individual rooms to separate patients; (3) for cleaners: using low volatile organic compound emission detergents; (4) for nurses: making bed gently, and strictly using personal protective clothing (mask) during nebulization therapy or when patients are coughing. To our knowledge, we have conducted the first comprehensive measurements of indoor/outdoor particle number, particle mass and indoor bioaerosol characteristics in a PICU environment. The average indoor PN and PM 10 concentrations in the PICU were substantially lower than outdoors. The contribution of outdoor particles to indoor particle concentrations was very low for both PN and PM 10 . This result could be due to the two-stage filters (primary filter: fabric bag; secondary filter: HEPA filter) which achieve 99.99% filtration efficiency. However, regular maintenance of the ventilation system is needed to ensure the HEPA filters are in good working order. There were strong indoor particle sources in the PICU, which could significantly increase indoor particle concentrations up to 100 times for PN and 68 times for PM 10 . The main indoor sources for particle generation identified in the PICU were nebulization therapy, tracheal suction and cleaning activities. There were also some particle sources that were not identified, due to a lack of recorded activity information. Based on multipoint measurement data, the spatial variation of particle concentration in the PICU was low because of rapid transport of particles generated across the whole area of the PICU. Surprisingly, particles generated in the isolated single room (Bed 2) were also transported to other open areas or other beds. Despite the transport of particles from the isolation room to other areas of PICU, this study showed lower bioaerosol concentrations compared with the previous research in PICU environments. Therefore, the results of this study indicate that the likelihood of bioaerosols being transported from the isolation room to other areas of the PICU is small; however, it is still an infection control risk, especially in the absence of viruses being detected in airborne particles in our study. The multipoint measurement database obtained from this study not only improved our understanding about the transport, mixing and dilution of the particles present in the ward, but also will be useful to validate indoor particle dynamic modelling. This might be further helpful to those formulating strategies for better ventilation of hospital wards, as well as infection or air indoor air pollutant control and management. Five samples in both the primary culture and the broth culture had a polymicrobial infection with two species identified in each sample. a One collection had insufficient sample for processing. b Recognized pathogens include Staphylococcus aureus (n = 1), Enterobacter cloacae (n = 1), Pantoea dispersa (n = 2). for her assistance with this project. The authors also would like to express their gratitude to the parents of the patients in the PICU for their understanding and help with this project. Dr. Zhen Liang gratefully acknowledges financial support from China Scholarship Council. L.D.K. acknowledges an NHMRC Early Career (Australian Public Health) Fellowship (APP1036620). The authors also would also like to thank Helen Jeays for language editing. Newly identified respiratory viruses in children with non-hospitalised asthma exacerbation Extra length of stay and costs because of health care-associated infections at a German university hospital Hospital outbreak of middle east respiratory syndrome coronavirus ABC of intensive care: organisation of intensive care Measles outbreak in a pediatric practice: airborne transmission in an office setting Emergence and spread of a human-transmissible multidrug-resistant nontuberculous mycobacterium The impact of viral respiratory infection on the severity and recovery from an asthma exacerbation Microarray detection of human parainfluenzavirus 4 infection associated with respiratory failure in an immunocompetent adult The impact of hospital-acquired infections with multidrug-resistant bacteria in an oncology intensive care unit Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward The burden of respiratory syncytial virus bronchiolitis on a pediatric inpatient service Indoor mass concentrations of particulate matter in hospital environment Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air Contribution from indoor sources to particle number and mass concentrations in residential houses The impact of flood and post-flood cleaning on airborne microbiological and particle contamination in residential houses Indoor air quality varies with ventilation types and working areas in hospitals Routes of influenza transmission Skin microbiome: looking back to move forward Evidence of respiratory syncytial virus spread by aerosol: time to revisit infection control strategies Airborne transmission of chickenpox in a hospital Epidemiology and risk factors for severe respiratory syncytial virus infections requiring pediatric intensive care admission in Hong Kong children Bioaerosol characteristics in hospital clean rooms Concentrations and sources of airborne particles in a neonatal intensive care unit Real-time reverse transcription-PCR assay for comprehensive detection of human rhinoviruses Role of mechanical ventilation in the airborne transmission of infectious agents in buildings Co-circulation of four human coronaviruses (HCoVs) in Queensland children with acute respiratory tract illnesses in 2004 Indoor Environment: Airborne Particles and Settled Dust Characteristics of particle number and mass concentrations in residential houses in Ultrafine particles in indoor air of a school: possible role of secondary organic aerosols Influence of ventilation and filtration on indoor particle concentrations in urban office buildings Co-optimisation of indoor environmental quality and energy consumption within urban office buildings Bioaerosol production on a respiratory ward Airborne transmission of communicable infection-the elusive pathway guideline for isolation precautions: preventing transmission of infectious agents in health care settings Impact of patient visiting activities on indoor climate in a medical intensive care unit: a 1-year longitudinal study Hospital-acquired influenza: a synthesis using the outbreak reports and intervention studies of nosocomial infection (orion) statement Airborne transmission of Bordetella pertussis Infection Prevention and Control of Epidemic-and Pandemic-Prone Acute Respiratory Infections in Health Care Hospital organisation, management, and structure for prevention of health-care-associated infection: a systematic review and expert consensus The study was partially supported by the Institute of Health and Biomedical Innovation, QUT, within the Collaborative Research Development Grant Scheme. The authors would like to acknowledge Joyce Cheney, Children's Health Queensland Hospital and Health Service, Lady Cilento Children's Hospital, for her great help and support. The assistance of nurses and staff from the PICU is gratefully acknowledged. Member from ILAQH, especially Chantal Labbe is thanked Supplementary data to this article can be found online at http://dx. doi.org/10.1016/j.envint.2017.06.020.