key: cord-0728904-5aru2pw8 authors: Lau, Zechariah; Griffiths, Ian M.; English, Aaron; Kaouri, Katerina title: Predicting the spatio-temporal infection risk in indoor spaces using an efficient airborne transmission model date: 2022-03-16 journal: Proc Math Phys Eng Sci DOI: 10.1098/rspa.2021.0383 sha: f41b620e899693d5986917c0a5374f05fa41209b doc_id: 728904 cord_uid: 5aru2pw8 We develop a spatially dependent generalization to the Wells–Riley model, which determines the infection risk due to airborne transmission of viruses. We assume that the infectious aerosol concentration is governed by an advection–diffusion–reaction equation with the aerosols advected by airflow, diffused due to turbulence, emitted by infected people, and removed due to ventilation, inactivation of the virus and gravitational settling. We consider one asymptomatic or presymptomatic infectious person breathing or talking, with or without a mask, and model a quasi-three-dimensional set-up that incorporates a recirculating air-conditioning flow. We derive a semi-analytic solution that enables fast simulations and compare our predictions to three real-life case studies—a courtroom, a restaurant, and a hospital ward—demonstrating good agreement. We then generate predictions for the concentration and the infection risk in a classroom, for four different ventilation settings. We quantify the significant reduction in the concentration and the infection risk as ventilation improves, and derive appropriate power laws. The model can be easily updated for different parameter values and can be used to make predictions on the expected time taken to become infected, for any location, emission rate, and ventilation level. The results have direct applicability in mitigating the spread of the COVID-19 pandemic. We develop a spatially dependent generalization to the Wells-Riley model, which determines the infection risk due to airborne transmission of viruses. We assume that the infectious aerosol concentration is governed by an advection-diffusionreaction equation with the aerosols advected by airflow, diffused due to turbulence, emitted by infected people, and removed due to ventilation, inactivation of the virus and gravitational settling. We consider one asymptomatic or presymptomatic infectious person breathing or talking, with or without a mask, and model a quasi-three-dimensional set-up that incorporates a recirculating air-conditioning flow. We derive a semi-analytic solution that enables fast simulations and compare our predictions to three reallife case studies-a courtroom, a restaurant, and a hospital ward-demonstrating good agreement. We then generate predictions for the concentration and the infection risk in a classroom, for four different ventilation settings. We quantify the significant reduction in the concentration and the infection risk as ventilation improves, and derive appropriate power laws. The model can be easily updated for different parameter values and can be used to make predictions on the expected time taken to become infected, for using the Wells-Riley ansatz. In §3, we discuss the parameter values in our model and how these may be easily changed once updated knowledge becomes available. In §4, we apply our model to three real-life case studies and find good agreement with data. We first compare the model with data from two superspreader outbreaks. The first outbreak occurred at a courtroom in Switzerland in October 2020 [30] , where five out of 10 people present tested positive a few days after a hearing. The second outbreak occurred at a restaurant in Guangzhou, China, in January 2020; seven to nine people out of 20 were infected [31] . Satisfactory agreement with two CFD models that simulated the restaurant outbreak is also obtained [17, 32] . We also consider air-sampling data in a hospital ward, as reported in [33] . Subsequently, in §5 we apply the model to an average-sized classroom. We determine how the aerosol concentration and the infection risk change for four different ventilation settings: very poor ventilation, poor ventilation, the ASHRAE (American Society of Heating, Refrigeration and Air-Conditioning Engineers [81] ) recommended minimum ventilation for classrooms, and a ventilation setting better than the ASHRAE recommended minimum. In §6, we summarize our work and indicate how policy-makers and other decision-makers could use the model in future planning to tackle the pandemic. Below, we develop our model and explain major assumptions. As discussed in the Introduction, while the Wells-Riley model leads to fast predictions, it does not capture spatial effects. Since a CFD approach is very time consuming, we develop a quick-to-run quasi-three-dimensional, spatio-temporal model for the concentration of viral aerosols indoors and the infection risk. We consider an infectious person talking or breathing, with or without a mask. We also assume that the room contains an air-conditioning unit, which drives a recirculating flow, as shown in figure 1 and as predicted by van Hooff et al. [34] . We show that the model possesses a semi-analytic solution and, thus, predictions can be generated very quickly. The infectious person acts as a source of infectious aerosols, S inf . For simplicity, we make the assumption that all aerosols are of the same size and carry the same amount of virus, but note that this can be readily generalized for particle-size distributions [35] . The aerosols are transported by advection caused by the airflow, which follows the recirculating loop as shown in figure 1 , and has velocity, v. Even though air is expelled from the mouth and nose during breathing and talking, this is a local and temporary effect, so it is fair to assume that the aerosols are passively released into the flow stream, 1 so that the advection velocity of the aerosols is also v. The infectious aerosols are assumed to be removed due to three factors: ventilation, biological deactivation of the virus, and gravitational settling. These correspond to sink terms, which we denote by S vent , S deact , and S set , respectively. Finally, we assume turbulent mixing of the air. Turbulence leads to the aerosols diffusing much more rapidly than due to Brownian motion [36] . Turbulent diffusion is governed by the eddy diffusion coefficient, K (m 2 /s) [36] . More details are given in §2(b). From these assumptions, we arrive at the advection-diffusion-reaction (ADR) equation, the governing equation for the concentration of infectious aerosols, where C is the concentration of infectious aerosols (aerosols/m 2 ) at all points on the surface of the looping airflow, t is the time (s) [37] , and ∇ = (∂/∂ξ , ∂/∂y) is the two-dimensional gradient operator in the surface of the looping airflow, where ξ (m) denotes the arclength in the streamwise direction of the flow and y (m) is the coordinate transverse to the flow. The upper and lower branches of the surface are assumed to be separated by a distance h/2, following [34] (figure 2a). Following [38] , we model an infected person who is breathing or talking as a continuous point source emitting virus-carrying aerosols at a constant rate of R aerosols/s. We choose to use the infectious aerosol emission rate instead of the traditional quanta generation rate in the Wells-Riley model for reasons that are discussed in §2(d). We also assume that inhaling and exhaling occur at the same rate, so there is no net source or sink of air from the emitter and receiver of the aerosols. Thus, an infectious person talking or breathing at position (ξ 0 ,y 0 ) is modelled as follows: where λ is the air exchange rate of the room, measured in s −1 . This is an approximation, since ventilation is a localized effect, with removal of the air occurring at a higher rate near the air vents and openings in the room [40, 42] . However, our approach still allows inclusion of the effect of ventilation while retaining its key features and without greatly increasing the mathematical complexity of our model. Following [22] , we model the biological deactivation and gravitational settling as global firstorder removals, as follows: and S set = −σ C, (2.5) where β is the viral deactivation rate and σ is the aerosol settling rate, both measured in s −1 . While gravitational settling would induce interaction between the two layers due to the size of the aerosols (about 5 µm [2] ), it would take about 4 h for them to fall from layer 1 to layer 2, if a perfect vertical fall is assumed. However, these aerosols will not follow a perfect vertical motion as a result of the recirculation; it takes only minutes for an aerosol to loop around the room. Thus, the aerosols are much more likely to be carried from the upper layer to the lower layer by the recirculating airflow than fall into the lower layer from the upper layer. Furthermore, most of the virus in the aerosols is deactivated within 1-2 h (see §2(a)). Therefore, in our model we assume that we can neglect the layer-layer interaction. The typical airflow from an air-conditioning unit, |v| = 0.1 − 1 m s −1 [43] , is small compared with the speed of sound (340 m s −1 ), so we may assume that the air is an incompressible fluid [44] ; that is, The velocity, v, is controlled solely by the air-conditioning unit, which we assume has an inlet in the left wall, and we assume that the airflow velocity at all points in the surface of the loop is constant and uniform, i.e. v = (v, 0), where v is a constant. To determine K, the eddy diffusion coefficient, we use the following formula: Here, c k is the von Karman constant, Q is the total volume flow rate into the room, V is the room volume, N is the number of air supply vents, and c is the constant of proportionality in Taylor's Dissipation Law [45, 46] . The relation (2.7) was presented in [41] and is based on the turbulent kinetic energy balance (TKEB) relationship initially proposed in [45] for rooms served by mixing ventilation (i.e. when cool air is blown in through the ceiling or wall and dilutes the room air [47] ; see figure 1 for an example). Since Q = Vλ, (2.7) may be rewritten as We assume the relationship c = c 3 k following [45, 48] . Taking c k = 0.39 [49] gives c = 0.059. (We note that different formulae for c have been used, for example, c = c k [39] and c = 0.5c 3 k [41] , albeit without providing a rationale.) For a room with length l and width w, we unwrap the loop surface of the airflow to the twodimensional domain (ξ , y) ∈ [0, 2l] × [0, w] (figure 2b). This extended domain allows us to model the evolution of the aerosol cloud in both the upper and lower layers of the flow stream in a simpler way. Assuming there is only one infectious person, we substitute equations (2.2)-(2.6) into the ADR equation (2.1) to obtain the partial differential equation (PDE) we will be solving, as We assume that no virus-carrying aerosols are present initially. Hence, the initial condition is We model the recirculating flow using the following domain and boundary conditions. In our set-up, the aerosols loop around the room; we model this through periodic boundary conditions on the concentration and its derivative at the wall ξ = 0 and opposite side of the extended domain, at ξ = 2l. Hence, The system is closed by applying Neumann boundary conditions at the walls located at y = 0, w as follows: The conditions (2.11c) correspond to perfect reflection of aerosols at the wall. In practice, some aerosols may be absorbed by the wall and so our model represents a worst-case scenario in this respect. (c) The semi-analytic solution for the viral aerosol concentration We solve the PDE (2.9) with the boundary conditions (2.11a-c) and initial condition (2.10) by first solving the homogeneous problem to determine the impulse function. Then, we convolve the impulse with the source function (2.2) to obtain the full solution (see [50] for details). A solution to the homogeneous problem of the form C(ξ , y, t) = e −(λ+β+σ )t A(ξ , y, t) is assumed [50] . We then use separation of variables to reduce the problem to two one-dimensional diffusion problems [50] . Owing to the periodic and Neumann boundary conditions (2.11a-c), we can use the method of images [51] when solving for the impulse function. Hence, the solution is given by Now, by leveraging the mapping of the quasi-three-dimensional set-up to a two-dimensional geometry, we can average the aerosol concentration in the upper and lower branches of the loop surface to determine the concentration for the quasi-three-dimensional set-up. Specifically, we define x ∈ [0, l] to be the Cartesian coordinate in the direction of the upper flow, so x = ξ , 0 ≤ ξ ≤ l defines the upper branch and x = 2l − ξ defines the lower branch, for l ≤ ξ ≤ 2l (figure 2a). The concentration of viral aerosols in the upper branch is then given by C upper (x, y, t) = C(x, y, t), (2.13) and the concentration of viral aerosols in the lower branch is given by Recall that we assume the separation between the two branches is half the height of the room. We assume that within the two branches the air is well mixed and use this to transform the twodimensional expressions back into a three-dimensional representation By modifying equation (2.15 ) and placing the source in the appropriate layer, we are equally able to account for people who are standing, sitting, or lying down. We then substitute (2.12) into (2.15) to obtain the total concentration Following the Wells-Riley ansatz, we assume an exponential probability density function for a susceptible person being infected from aerosols as a function of the dose of viral aerosols inhaled, d [20, 29, 52] , We then calculate d from the formula given in [15, 20] as Here, ρ is the average breathing rate of the susceptible person, i.e. the average volume of air inhaled per second, and C(x, y, t) is given by (2.17 Here, I is a conversion factor that allows to obtain the number of infectious aerosols in terms of the quanta emission rate [24] . A quantum is defined as the dose of airborne virions corresponding to an infection risk of 1 − e −1 ≈ 63%; that is, 63% of susceptibles getting infected [20, 21] . The parameter I is also related to the median infectious dose, d m , the dose of airborne virions causing infection to 50% of the susceptible population, by Here, μ is the expected number of viral copies in each aerosol, which is given by [35, 53] where c v is the viral load (viral copies/ml) of the virus in biological samples (usually sputum or saliva for SARS-CoV-2) and d p is the average diameter of the aerosols released. The quanta emission rate, q, is related to I via q = RI. (2.23) We choose not to use the infectious quantum as the unit in (2.1) and (2.2), and to work in terms of R and I instead, since the predictions of this model may then be more easily regenerated when either of these parameter values is updated. The value of R changes with the type of activity but is currently uncertain. Also, the value of I may change independently since the dose may change with the severity of the COVID-19 disease [54, 55] ; age has also been suggested to influence disease severity [56, 57] . Moreover, it has been suggested that some SARS- In this section, we discuss the model parameters that are independent of the room configuration and give the values we choose. For each case study we examine, additional location-specific parameter values are given in the electronic supplementary material. The infectious aerosol emission rate, R, is obtained from the rate of the total number of aerosols generated, R total , by Currently, there is no agreed value for the total aerosol emission rate, R total , in the literature. Also, μ varies as it is proportional to the viral load, c v , (see equation (2.22) ), which varies for each infectious person and their stage of infection [59] [60] [61] . For instance, the airborne transmission models in [24, 27, 35, 62] all use different values for R total , following [63] [64] [65] [66] , respectively; these values are compiled in table 1. Some of these papers present the emission rate in terms of number of aerosols per volume of breath exhaled, R V = R total /ρ inf , where ρ inf is the average breathing rate of the infectious person. However, there seems to be a consensus [63] [64] [65] that speaking is assumed to release significantly more aerosols than breathing; here, we assume that speaking generates 10 times more aerosols than breathing. Following [27, 64] , we assume that the total aerosol emission rate, R total = 8 aerosols/s for breathing and R total = 80 aerosols/s for talking. The parameter values used are collected in table 2. We assume that the average aerosol diameter, d m = 5 µm according to the definition of airborne droplet nuclei from the WHO [2] . The viral load in the mouth, c v , on the other hand, varies for each infectious person and their stage of infection [59] [60] [61] . Values of c v have been found in the range of 10 3 -10 12 viral copies ml −1 , with the median value about 10 6 viral copies ml −1 [59] [60] [61] . However, Srinivasan et al. [72] and Lee [68] report that the minimum viral loads required for aerosol transmission were 10 8 -10 9 viral copies ml −1 . Hence, in our simulations for the two superspreader outbreaks (courtroom and restaurant), as well as for the study in the hypothetical classroom later, we choose c v ≥ 10 9 viral copies ml −1 . Hence, from equation (2.22), μ ≥ 6.5% of aerosols carry a copy of the SARS-CoV-2 virus. From equation (3.1), the emission rate of virus-carrying aerosols is then R ≥ 0.5 aerosols/s for breathing and R ≥ 5 aerosols/s for talking. We note that in (2.17), C is proportional to the strength of the source, R, as expected. Henceforth, we will also use the dimensionless parameter R = R/R 0 , where R 0 is the rate of emission of infectious aerosols when breathing (see tables 2 and 3). In this way, the results may be easily scaled when better estimates of R become available. Table 3 . The rate of emission of infectious aerosols by a person and the corresponding non-dimensional rate, R, when breathing or talking, and with and without a mask, scaled by the emission rate during breathing, R 0 = 0.5 aerosols/s. We quantify the reduction in the infection risk when the infectious person wears a face mask. Therefore, we introduce a parameter, η, that measures the efficiency of the mask, so The efficiency of surgical masks and N95 respirators is well documented [73, 74] . However, due to the sudden demand due to the COVID-19 pandemic, there has been a shortage of such masks and many people have had to manage with cloth masks. The efficiency of these masks is not well studied: at the moment there is only a preliminary study by Fischer et al. [69] , which suggests that the efficiency is at least 50%. Furthermore, a fraction of people wear their masks incorrectly, which reduces their efficiency. Thus, we shall assume that a mask with an efficiency of 50% represents a reasonably realistic scenario. For the viral deactivation rate, β, according to [70] , artificially generated aerosols carrying SARS- In our simulations, we will take β = 1.7 × 10 −4 s −1 . We must caution that this value of β is for artificially generated aerosols in a controlled laboratory environment and may be different for naturally produced bio-aerosols. However, our model can easily be updated if more accurate estimates emerge. For the gravitational settling parameter, σ , we refer to [35] . Here, aerosols released by respiratory activities were found to have a mean value of σ = 0.39 h −1 ≈ 1.1 × 10 −4 s −1 ; we take this value for our work. At present, the median infectious dose, d m , is unknown for SARS-CoV-2. Early estimates by Vuorinen et al. [15] , Basu [71] , and Karimzadeh et al. [75] suggest that d m for airborne COVID-19 is O(100) virions. We take d m = 100 virions for our analysis but keep in mind that this may be updated in the future. Dabisch et al. [54] recently showed that in primates, d m for seroconversion was 52 and d m for fever was 256 virions; our choice lies between these values. As μ < 1, when d m = 100 virions, (2.21) gives I ≈ 0.0069. Using the latter value of I and also R as in table 3, equation (2.23) gives q = 12.4 quanta/h for breathing and 124 quanta/h for talking. In [25] , they estimate the average q to be 14-48 quanta/h, which is comparable to our value for breathing. On the other hand, our values are in the 95th-99th percentile of the values obtained in [62] . Our high values of q are due to a higher value of c v that we assumed following [53, 68] and because we chose a value of d m that probably corresponds to a worst-case scenario. We collect parameter values for this section in table 2. The results of our model, as well as those of most other models for COVID-19 transmission, should be interpreted with caution until these values are confirmed. In the subsequent simulations, we implement the solution for the concentration (2.17) in Python 3.8.5 64-bit. The convolutions are performed using the convolve function from the scipy.signal subpackage, which convolves two N-dimensional arrays [76] . To achieve satisfactory accuracy, we use a time step of 1s. The first infinite series in (2.17) is evaluated for m ≤ |vt/2l| as this is the number of times an aerosol travels around the recirculation surface during the time t. The second infinite series in (2.17) only needs to be evaluated for −3 ≤ n ≤ 3, as the steep exponential decay of the terms ensures very good accuracy with only the first few terms in the series [40] . For the courtroom case study (see §4(a)), as v = 0, so m = n ≤ |3| (see electronic supplementary material, table S1 for more information). For the restaurant case study (see §4(b)), m ≤ |45|. For the hospital case study (see §4(c)), m ≤ |77|. Finally, for the hypothetical classroom case study (see §5), m ≤ 135. To determine the infection risk (2.19), we apply the cumtrapz function from the scipy.integrate subpackage, which cumulatively integrates an array of values using the trapezoidal rule [76] , to the results of the convolutions. All plots are produced using the Matplotlib library [77] . The contour plots of the concentration and probability of infection are generated using a rectangular mesh of size 0.05 m. The computation time required is approximately 1 min for 1 h of real time. We run the simulations on a 2012 MacBook Pro laptop, with a 2.5GHz Dual Core Intel Core i5-3210M processor and 4GB 1805MHz RAM. (c) Ease of updating the model Owing to our model's quick runtime, the results can easily be updated when the values of R and I are updated; for example, due to new variants of the virus. We can also easily update our results for different settings, activity types, and ventilation levels. For example, we could quickly generate predictions for a person wearing a surgical mask or exercising in a gym. See electronic supplementary information, §1, for more details on how to update the results for several cases of interest. . Schematic for the courtroom case study described in [30] . P1 is the infectious person, a circled X is an infected person, and X is an uninfected person. We apply our model to a series of real-life case studies: two superspreader outbreaks in a courtroom in Switzerland [30] and at a restaurant in Guangzhou, China [31] , and air-sampling data from a hospital ward [33] . Ventilation quality varies between these case studies; the courtroom was very poorly ventilated due to a breakdown of the ventilation system, the restaurant was poorly ventilated with recirculation of the air from the air-conditioner increasing transmission and the hospital was very well ventilated. For these case studies we generate predictions for the aerosol concentration, the dose inhaled, or the infection risk, depending on the data available, and we find good agreement. The model predictions also agree well with those made by CFD models, when they are available. More details are provided in the electronic supplementary material, §2. (a) Courtroom superspreader outbreak: comparison with data We consider a courtroom in Vaud, Switzerland [30] , that was poorly ventilated due to a breakdown in the mechanical ventilation system. Within days of a 3-h hearing in October 2020, five out of the 10 people present tested positive. Figure 3 shows the seating positions of the people in the courtroom. P1 was the infectious person. The infected people-P2, P3, P4, and P5-were seated within 3.5 m of P1, while people seated further away (P6-P9) were not infected. P10 also sat within 3.5 m but was in the room for only 34 min, as a witness. We run our model for a three-hour 3-h event. As P1 was mostly silent according to the report of the hearing, we assume R total = 8 aerosols/s. Assuming a viral load c v = 5 × 10 9 (which is at the lower end of the viral loads required for aerosol transmission [68, 72] ) leads to μ = 33% and hence R = 2.5 aerosols/s. Taking also I = 0.0069 corresponds to an emission rate of 62 quanta/h. This provides a spatially averaged probability of 39%, which matches well with four people infected by P1 out of nine. (Note that our quanta emission value is approximately half of the quanta emission rate of 130 quanta/h found by back-calculation in [30] using the Wells-Riley model.) In table 4 we present the dose inhaled by each person normalized by the dose inhaled by P2, who was closest to P1, as well as the infection risk. According to our model, P2-P5 were exposed to significantly more infectious aerosols than P6-P9 and, correspondingly, to a quite high infection risk compared with the not-infected individuals. This matches up with P2-P5 becoming infected. See electronic supplementary material, §2.1, for more details. (b) Guangzhou restaurant superspreader outbreak: comparison with data and with CFD models A superspreader outbreak occurred at a restaurant in Guangzhou, China, on 23 January 2020 [31] . In [17] , they found that the airflow from the five air-conditioning units in the restaurant Table 4 . Comparing the results of our model with data from the courtroom case study in [30] where five out of 10 people tested positive a few days after a 3-h hearing. P1 was the infectious person and infected P2-P5. P10 was in the room only for 34 min. We assume R = 2.5 aerosols/s and I = 0.0069, which is equivalent to 62 quanta/h. The dose was normalized by the dose inhaled by P2. We take parameter values as in table 2 and the electronic supplementary material, table S1, formed 'recirculation zones'. In the recirculation zone where the infectious person was, the airconditioning stream carried the infectious aerosols to the opposite window, then the stream bent downward and returned at a lower height, before finally the contaminated air rose and returned to the air-conditioning unit, repeating the cycle [17] . Seven to nine people out of 20 were infected in one of these recirculation zones [31] , which corresponds to an infection rate of 35-45%. We simulate the concentration and infection risk using our model. We take as the computational domain a simplified rectangular domain 6 (l) × 17 (w) × 3.14 m (h)-see figure 4a. In figure 4b, we show in more detail the area of interest, which contains the recirculation zone in which the infectious person (A1) was sat, at Table A . We also show Tables B and C, which were also in this recirculation zone. Assuming that the infected person was talking without a mask, the emission rate R = 5 aerosols/s, and I ≈ 0.0069 (equivalent to 124 quanta/h). In figure 5a, we show the spatially varying infection risk and in figure 5b the average infection risk in the area of interest, as generated using our model, after 82 min. We have chosen 82 min since it is the time the infectious individual remained in the restaurant. The spatially averaged infection risk, P, is 40% after an hour and over 50% after 82 min. Although 50% might be an overestimation of the infection risk, recall that we assumed the person was continuously talking, whereas s/he must have had periods when s/he was eating. Table 5 shows the average infection risk at Tables B, C , and E. Tables B and C in the area of interest have a significantly higher risk than Table E , which is an equal distances away from Table A but outside this area. Comparing also Tables B and C, which are similar distances away from Table A, the infection risk was lower at Table B since people stayed there 53 min versus 77 min at Table C . (See electronic supplementary material, §2.2, for more details.) Therefore, our model is in good agreement with the data. If the Wells-Riley model had been used, it would not have been able to identify the heightened risk in the area of interest. Furthermore, as the risk in the Wells-Riley model would have been averaged over the whole restaurant, back-calculation of the quanta emission rate would result in an extremely alarming figure. CFD models in [17, 32, 78] have also been used to study this superspreader case. Using our model, we find that in this region the average concentration after 1 h is five times higher than what the maximum concentration would have been without recirculation (see the electronic supplementary material, figure S5 , §2, for more details); these results agree with [32] . With our model, we also determine the dose inhaled normalized by the dose inhaled by a person seated next to the infectious person; see In [33] , the concentration was sampled at two points in a COVID-19 hospital ward of area 7 × 3.5 m over 3 h. A single patient was present. We choose to compare with this case because it provides clear information regarding the dimensions of the room, the ventilation system, and the sampling positions. Figure 6 shows a schematic of the COVID-19 ward described in [33] . Sampling Position 1 (S1) was at the left wall, about 2 m from the head of the patient (the viral source), and sampling Position 2 (S2) was at the bottom-right corner of the room, about 4.8 m from the head of the patient. Ventilation was very good, with λ = 6 h −1 . Neither the activity of the patient nor the viral load were reported in [33] . The location-specific parameters are in the electronic supplementary material, table S5, §2, and other parameters are as in table 2. Table 6 shows the comparison of our model with data from [33] . Our ratio of the concentrations at the two sampling locations is 1. 74 Figure 6 . Schematic of the COVID-19 ward described in [33] . S1 and S2 represent the locations of the air samplers. Table 5 . Normalized dose in the restaurant from [17] , normalized by the dose inhaled by a person seated at Table A, adapted from table 3 Countries have been debating the best practices for operating indoor spaces in schools and universities during the COVID-19 pandemic. Hence, we use our model to study the transmission of COVID-19 in an average classroom of dimensions 8 (l) × 8 (w) × 3 m(h)-see figure 7 . For this classroom, we assume that the air-conditioning drives an airflow with velocity v = 0.15 m s −1 [43] . All parameters associated with this location and their values are found in (5, 4) and B: (8, 8) are of particular interest and are studied in our analysis. where ASHRAE is the American Society of Heating, Refrigeration and Air-Conditioning Engineers [81] . Each setting is characterized by a different value of λ, the air exchange rate, which increases with ventilation quality. The eddy diffusion coefficient, K, is determined by (2.8) for each λ assuming N = 1 and its values are given in table 7. (a) The concentration of infectious aerosols Figure 8 shows, in a contour map, the concentration of the infectious aerosols in the classroom after 1 h, for the four ventilation settings. For all ventilation settings, the highest concentration is in the region directly downwind from the infectious person. The width of this region increases with the amount of ventilation, as it depends on the eddy diffusion coefficient, K, which is proportional to λ (see equation (2.8) ). The next highest concentration in the room is found upwind. The concentration decreases as one travels away from the infectious person in the direction orthogonal to the airflow. Our results agree qualitatively with those obtained from air sampling in hospital wards in Wuhan, conducted in [84] , which showed that virus-carrying aerosols were 'mainly concentrated near and downstream from the patients' and there was also an 'exposure risk upstream'. Note that we express the concentration in terms of R so that the same plot can be used for breathing or talking, with and without a mask, or indeed other activities. Figure 9 shows the concentration in the room versus time evaluated at Position A: (5, 4) and Position B:(8,8) (figure 7) . These two positions were chosen because, as seen in figure 8 , the highest concentration is at Position A while maintaining 1 m social distancing from the infectious person and the lowest concentration is at Position B. Figure 9 shows that the concentration increases initially, before reaching a steady state. For lower values of λ, more time is required to approach the steady-state concentration, as predicted also by the Gammaitoni-Nucci extension of the Wells-Riley model [22] . At point A, downwind from the source, figure 9a shows that the steady-state concentration is higher for lower values of λ, where there is less removal of infectious aerosols, as expected. Figure 9a also shows that we can obtain a power law of the form C(x A , y A , t) ∝ Rt α , where α ≈ 0.34 which is independent of the amount of ventilation; only the constant of proportionality depends on λ. The trend deviates from this power law (by more than 5%) when t ≈ 16 min. For positions that are outside the high-concentration regions, such as Position B in the corner, figure 9b shows that no scaling law is obeyed, due to the influence of the walls. Moreover, we see that the ASHRAE recommended ventilation settings 3 and 4 initially have higher concentrations before being overtaken by the poorer ventilation setting. This result occurs because the movement of the infectious aerosols in the direction orthogonal to the airflow is governed by the eddy diffusion coefficient, K, which increases with λ according to (2.8) . Since the ASHRAE recommended ventilation settings have higher values of K, the infectious aerosols diffuse faster in the y-direction to begin with. However, given sufficient time, the infectious aerosols in the poorer ventilation settings will also reach the farthest points of the room and the concentrations there will eventually surpass those in the ASHRAE recommended ventilation settings. This result is a first indication that a small amount of ventilation could actually increase the risk of transmission compared with the case of very poor ventilation. Figure 10 shows the probability of infection for the four ventilation settings we considered in the 8 × 8 × 3 m room after an infectious person breathes for 1 h. The contours in figure 10 are similar in shape to the concentration contours in figure 8 . This implies that the greatest risk of infection indoors is directly downwind from the infectious person and the risk decreases as we travel away from the source in a direction orthogonal to the airflow. Figure 11 shows the probability of infection versus time evaluated at Position A and Position B in the case-study classroom for the case of an infectious person breathing. In figure 11b, we can see the effect of the concentration building more slowly at very poor ventilation that we saw in figure 9b, with the probability of infection growing very slowly initially then overtaking the two ASHRAE recommended ventilation settings 3 and 4. As Position A and Position B are the locations with the highest and lowest infection risks, respectively, in the room while maintaining social distancing of 1 m, by examining these two points we have a range of the risk in the room. In figure 12 , we evaluate the spatially averaged probability of infection (2.20) and compare with the probability of infection derived by inserting the average concentration; the latter is according to the WMR assumption of the Wells-Riley model. We consider the infectious person talking. As figure 12b-d show, as ventilation improves, the spatially averaged probability is almost equal to the probability of the average concentration. However, for the very poor ventilation setting, figure 12a shows that the former is lower than the latter. This demonstrates that our spatially dependent model more accurately captures the infection risk in poorly ventilated environments compared with the Wells-Riley model. (5, 4) . In this case, a power law of the form C(x A , y A , t) ∝ Rt α is obeyed, where α ≈ 0.34; the trend deviates from this power law when t ≈ 16 min and the presence of the walls begins to influence the solution. (b) Evaluated at Position B: (8, 8) . In this case, the influence from the walls is significant for all times and hence no scaling law is obeyed. Values for R for breathing and talking, with and without masks, are given in table 3. (Online version in colour.) Paving the way towards formulating policy recommendations, we can also use the model to calculate the Time To Probable Infection (TTPI)-the time required for the infection risk at a point in the room to reach 50%. We present in figure 13 the spatially dependent TTPI for the case of an infectious person talking in the 8 × 8 × 3 m classroom. Figure 14 shows the relationship between the TTPI and λ at Positions A and B in our classroom case study, respectively. The TTPI monotonically increases with λ. We can extract the following values for the four ventilation settings. For very poor ventilation, TTPI ≈ 50 min and for poor ventilation, TTPI ≈ 100 min. For the two ASHRAE recommended ventilation settings, the TTPI exceeds 200 and 350 min, respectively. In figure 14a, we observe further evidence of the scalinglaw behaviour at Position A that was identified in figure 9a, by now finding that the TTPI satisfies the relationship TTPI ∝ λ γ , where γ ≈ 0.41 for λ < 1 h −1 , and a linear relationship, i.e. γ ≈ 1, for λ > 1 h −1 . We note that as Position A is the most dangerous point in the room with the lowest TTPI (while maintaining 1 m social distancing), the TTPI at A could be used to determine a 'safe occupancy time' for the whole room. At Position B, shown in figure 14b, at the top-right corner we see that the TTPI depends non-monotonically on λ with a TTPI attaining a minimum value (most dangerous point) for λ approximately equal to 0.6 h −1 . For values of λ lower than 0.6 h −1 the TTPI decreases with λ; for values of λ higher than 0.6 h −1 the TTPI again increases with λ. At first glance, this is perhaps counter-intuitive since it implies that more ventilation makes the room less safe, but it can be explained by the slower initial build-up of concentration for this range of λ (figure 9b). Crucially, this non-monotonic behaviour of the TTPI demonstrates that very low ventilation could increase the infection risk in some parts of the room away from the source, so a very important takeaway message is that increasing the ventilation a little could actually be worse. This supports the initial observation made in figure 9 . More significantly, as λ increases, the infection risks at both Positions A and B drop significantly and the TTPIs increase significantly-for example when we double λ from 3 to 6 h −1 for A, we go from TTPI = 200 to 370 min, and for B, we go from TTPI = 325 to 570 min. We note that figures 13 and 14 could be generated very quickly for any location, parameters, and ventilation settings of interest. Next, in order to quantify the dependence of the TTPI on the type of activity, we plot in figure 15 the TTPI versus R, the emission rate of infectious aerosols, for the four ventilation settings. At Position A there is a power law of the form TTPI ∝ R φ with φ ≈ −0.79, −0.85, −0.96, and − 0.99, respectively. At Position B, φ ≈ −0.75, −0.84, −0.96, and − 0.99, respectively. As expected, the TTPI decreases as R increases, at both A and B. As φ decreases with increasing ventilation, the dependence of TTPI on R becomes weaker with increasing ventilation. In other words, the more aerosols generated per second the less safe the room is, but when ventilation increases sufficiently the type of activity matters less. We also note that at Position B, for the poorer ventilation settings, the effects of the weaker mixing are visible again. Furthermore, as ρ and I have the same influence in (2.20) as R, we could also determine analogous power laws of the forms TTPI ∝ ρ or TTPI ∝ I ν . In figure 16 , we consider the TTPI at 1 m downwind in several other indoor spaces found in schools and universities: an office (4 × 4 m), an auditorium or lecture theatre (15 × 30 m), and a convention centre or indoor football field (68 × 105 m). We note that as the size of the room increases to infinity, φ → −1. Since φ decreases with increasing room size, this shows that the dependence of the TTPI on R becomes weaker with increasing room size. In this paper, we have addressed the urgent need for a quick-to-run and efficient model that determines the spatially dependent concentration of airborne particles (aerosols) carrying the SARS-CoV-2 virus and also the corresponding probability of infection (infection risk). The model compares well with data from three real-life case studies in a courtroom [30] , a restaurant [31] , and a hospital ward [33] , and also with CFD models (see §4). We have applied the model to predict the concentration and the infection risk in an average-sized classroom, and we have shown that the benefits of improving ventilation are significant. Our approach could be applied to any other room. We placed one infectious, asymptomatic, or presymptomatic person in the centre of the room who either breathes or talks, with or without a mask; this corresponds to four different emission rates for the viral aerosols (table 3). Note that we have taken the mask efficiency to be 50% but this number can be very easily altered (as well as all other parameters in the model). The semi-analytic solution we derived in §2(c) allows for fast simulations; for example, it takes only 1 min of simulation to determine the concentration after 1 h of real time, on a standard laptop. Subsequently, using the spatially varying concentration (2.17) in the well-known exponential probability density function of the Wells-Riley model [20, 29, 52] , we determine, for the first time, a spatially varying probability of infection (2.20) . The model relies on many parameters that are currently unknown for SARS-CoV-2 or which are known to vary over a wide range. Particularly uncertain parameters are the median infectious dose, and hence the conversion factor between dose of viral aerosols inhaled and infectious quantum, the viral load, and the length of time before the virus becomes biologically inactivated. We have used the best estimates for these parameters by consulting the literature and talking to scientists involved in experiments (see §3). However, our predictions must still be taken with caution. Our model provides an important contribution to the COVID-19 modelling field since it can be easily updated and rerun as and when more accurate estimates are obtained, or new estimates arise from new variants of the virus or from different types of activity, such as physical exercise (see §1 of electronic supplementary material). In §5, we applied the model to a hypothetical average-sized classroom, with dimensions 8 × 8 × 3 m (figure 7). Our model shows that the concentration and the infection risk in the room are highest downwind from the infectious person (figure 8). As in the Wells-Riley model, the concentration in the room increases initially, then reaches a steady state (see figure 9 ). We consider the concentration at two indicative points: A (1 m downstream of the source, assuming social distancing); and B (top-right corner). The time to reach the steady state is shorter and the steady-state concentration is lower for larger values of ventilation λ at Position A. However, at Position B the highest concentration is attained in the poor ventilation setting. Moreover, the ASHRAE recommended ventilation settings 3 and 4 exhibit higher concentrations than the very poor ventilation for some time before the poor ventilation surpasses these values. At Position A, the concentration obeys a power-law dependence on time to begin with, since the spreading behaviour is unimpeded by obstacles. However, as time progresses and the effect of the walls comes into play, the power law breaks down. Analogously, no power law exists for Position B, since the influence of the walls is significant at all times due to their proximity to this location. Another observation from figure 8 is that the second highest concentration level is found upwind of the source (on the same horizontal line). Our results agree qualitatively with airsampling data from hospital wards in Wuhan [84] , which showed that virus-carrying aerosols were 'mainly concentrated near and downstream from the patients' and there was also an 'exposure risk upstream'. In figure 10 , we show the probability of infection for the four ventilation settings we consider (8 × 8 × 3 m classroom, infectious person breathing for 1 h). The contours in figure 10 are similar in shape to the concentration contours in figure 8 . This implies that the greatest risk of infection indoors is directly downwind from the infectious person and the risk decreases as we travel away from the source in a direction orthogonal to the airflow. Figure 11 the probability of infection growing very slowly initially then surpassing the two ASHRAE recommended ventilation settings 3 and 4. As Position A and Position B are the locations in the room with the highest and lowest concentrations, respectively, they provide us with the range of the concentration and the infection risk in the room. In figure 12 , we present a comparison of the spatially averaged probability of infection versus the probability of infection obtained from the average concentration arising from our model. The latter infection risk is that predicted by previous, spatially uniform Wells-Riley models. We consider an infectious person talking in the 8 × 8 × 3 m classroom. As figure 12b-d show, as ventilation improves, the average probability becomes almost equal to the probability derived from the average concentration. However, for the very poor ventilation setting, figure 12a shows that the spatially averaged probability is lower than the probability from the average concentration in the room. This figure suggests that the spatially averaged (WMR) approximations may overestimate the infection risk for poorer ventilation settings. Paving the way for formulating policy-making recommendations, in §5(d) we used the spatially varying concentration to determine the TTPI as a function of ventilation λ. In the downwind region, 1 m away from the source (Position A), the TTPI increases with λ, exhibiting a scaling-law dependence on λ (figure 14a). Outside this high-concentration region (Position B), the TTPI, interestingly, exhibits a non-monotonic relationship with λ, first decreasing to a minimum TTPI and then increasing again with λ ( figure 14b ). This observation ties up with previous observations that improving ventilation a little may be worse than not doing anything. More significantly, figure 14 shows that increasing ventilation in a room can drastically reduce the infection risk and hence drastically increase the TTPI. We have also identified a power-law relation between the TTPI and R, the emission rate of airborne infectious particles, ( figure 15 ) that encapsulates the TTPI over a continuous range of R. Consequently, this can be used to quickly quantify the effect on the TTPI of the activity type for one person (for example, talking at low or high volume) or differences in the emission rate between persons (as some emit more viral particles than others for the same type of activity). We also note that this dependence of the TTPI on R becomes weaker with increasing room size (figure 16). Analogous power laws can be determined for the TTPI versus I, the conversion factor between the number of infectious aerosols and the infectious quantum in the probability density function (2.20) ; and for the TTPI versus ρ, the breathing rate of the susceptible person. These would allow us to quickly generate predictions for new variants, once the parameters are made available. The model could be extended in several ways to account for additional questions of interest. Currently, we are working on including viral particle-size distributions, particularly sizedependent gravitational settling and emission rates that depend on the particle size. Also of particular practical interest is quantifying the effect on the infection risk when air purifiers are introduced in rooms; a stream of work motivated by our industrial partner Smart Separations Ltd. The model can be extended to study rooms with more complex geometries, air velocities, and ventilation systems. Ventilation could be modelled as a localized effect with the removal of the air occurring faster near the air vents and room openings [40] . In conclusion, our model can be implemented to assess the risk of airborne infection in rooms of different sizes when an infectious person is breathing or talking, with or without a mask. It can also be implemented to quantify the effectiveness of changing the ventilation available in the room. The modelling framework contains a series of parameters that may easily be adjusted in light of new guidelines on ventilation or confirmed information on the virus. Most importantly for the current COVID-19 pandemic, it can be implemented quickly on individual, widely available, and inexpensive computers. Data accessibility. All scripts used in this study are openly accessible through https://github.com/zechlau14/ Modelling-Airborne-Transmission. The data are provided in electronic supplementary material [85] . .org/journal/rspa Proc. R. Soc conceptualization, formal analysis, investigation, methodology, software, validation, visualization, writing-original draft, writing-review and editing conceptualization, formal analysis, funding acquisition, investigation, methodology, project administration, supervision, writingreview and editing investigation, validation, visualization, writing-review and editing conceptualization, formal analysis, funding acquisition, investigation, methodology, project administration, resources, supervision, writing-review and editing All authors gave final approval for publication and agreed to be held accountable for the work performed therein. Competing interests. The authors declare we have no competing interests gratefully acknowledge funding from a Sêr Cymru COVID-19 grant, awarded by the Welsh government. I.M.G. gratefully acknowledges support from the Royal Society via a University Research Fellowship. References 1. World Health Organisation. 2020 WHO Coronavirus disease (COVID-19) dashboard World Health Organization. 2020 Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations: Scientific brief 2020 Virology, epidemiology, pathogenesis, and control of COVID-19 The Coronavirus pandemic and aerosols: does COVID-19 transmit via expiratory particles? It is time to address airborne transmission of Coronavirus Disease 2019 (COVID-19) Scientific brief: SARS-CoV-2 and potential airborne transmission. United States Guidance: Ventilation of indoor spaces to stop the spread of Coronavirus (COVID-19) Using the contact network model and Metropolis-Hastings sampling to reconstruct the COVID-19 spread on the Mechanistic transmission modeling of COVID-19 on the Diamond Princess cruise ship demonstrates the importance of aerosol transmission Relative contributions of transmission routes for COVID-19 among healthcare personnel providing patient care Agent-based modeling to evaluate nosocomial COVID-19 infections and related policies Relative contributions of four exposure pathways to influenza infection risk Introduction to particle Markov-chain Monte Carlo for disease dynamics modellers On the effect of the respiratory droplet generation condition on COVID-19 transmission /journal/rspa Proc. R. Soc Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors Influence of wind and relative humidity on the social distancing effectiveness to prevent COVID-19 airborne transmission: a numerical study Probable airborne transmission of SARS-CoV-2 in a poorly ventilated restaurant 2021 Risk assessment of airborne transmission of COVID-19 by asymptomatic individuals under different practical settings Modeling airborne pathogen transport and transmission risks of SARS-CoV-2 Airborne spread of measles in a suburban elementary school Airborne contagion and air hygiene. An ecological study of droplet infections Using a mathematical model to evaluate the efficacy of TB control measures COVID-19 aerosol transmission estimator Estimation of airborne viral emission: quanta emission rate of SARS-CoV-2 for infection risk assessmen Association of the infection probability of COVID-19 with ventilation rates in confined spaces 2020 The efficacy of social distance and ventilation effectiveness in preventing COVID-19 transmission Model calculations of aerosol transmission and infection risk of COVID-19 in indoor environments Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event Predictive and retrospective modelling of airborne infection risk using monitored carbon dioxide 2021 Probable aerosol transmission of SARS-CoV-2 in a poorly ventilated courtroom COVID-19 outbreak associated with air conditioning in restaurant The build-up of aerosols carrying the SARS-CoV-2 Coronavirus 2020 Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients On the suitability of steady RANS CFD for forced mixing ventilation at transitional slot Reynolds numbers 2021 Evolution of spray and aerosol from respiratory releases: theoretical estimates for insight on viral transmission Turbulent eddy diffusion models royalsocietypublishing.org/journal/rspa 2020 Modeling of viral aerosol transmission and detection Modeling indoor air exposure from shortterm point source releases Turbulent eddy diffusion models in exposure assessment -Determination of the eddy diffusion coefficient 2020 A relationship for the diffusion coefficient in eddy diffusion based indoor dispersion modelling On airborne virus transmission in elevators and confined spaces Elementary fluid dynamics Can weak turbulence give high concentrations of carbon dioxide in baby cribs Statistical theory of turbulence IV-diffusion in a turbulent air stream Room air and contaminant distribution in mixing ventilation A predictive numerical model of the Atmospheric Boundary Layer based on the Turbulent Energy Equation A new value of the von Kármán constant: implications and implementation Partial differential equations Conduction of heat in solids Development of a doseresponse model for SARS Coronavirus Size distribution of virus laden droplets from expiratory ejecta of infected subjects Seroconversion and fever are dose-dependent in a nonhuman primate model of inhalational COVID-19 The K18-hACE2 transgenic mouse model recapitulates non-severe and severe COVID-19 in response to infectious dose of SARS-CoV-2 virus Age-dependent effects in the transmission and control of COVID-19 epidemics 2021 COVID-19 hospitalization rates rise exponentially with age, inversely proportional to thymic T-cell production Increased transmissibility of emerging SARS-CoV-2 variants is driven either by viral load or probability of infection rather than environmental stability Virological assessment of hospitalized patients with COVID-2019 2020 Viral load of SARS-CoV-2 in clinical samples Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: prospective and retrospective applications Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities Aerosol emission and superemission during human speech increase with voice loudness Modality of human expired aerosol size distributions The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission 2021 Physiology, Tidal volume Why does the SARS-CoV-2 Delta VOC spread so rapidly? Universal conditions for the rapid spread of respiratory viruses, minimum viral loads for viral aerosol generation, effects of vaccination on viral aerosol generation, and viral aerosol clouds Low-cost measurement of face mask efficacy for filtering expelled droplets during speech Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1. New Engl Close-range exposure to a COVID-19 carrier: transmission trends in the respiratory tract and estimation of infectious dose Modeling the viral load dependence of residence times of virus-laden droplets from COVID-19-infected subjects in indoor environments In vivo protective performance of N95 respirator and surgical facemask On respiratory droplets and face masks Review of infective dose, routes of transmission and outcome of COVID-19 caused by the SARS-COV-2: comparison with other respiratory viruses SciPy 1.0: Fundamental algorithms for scientific computing in python Matplotlib: a 2D graphics environment Modelling airborne transmission and ventilation impacts of a COVID-19 outbreak in a restaurant in Guangzhou Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom 1-2019, Ventilation for acceptable indoor air quality The ventilation of buildings and other mitigating measures for COVID-19: a focus on wintertime Standard 170-2017, Ventilation of health care facilities Aerosol and surface distribution of Severe Acute Respiratory Syndrome Coronavirus 2 in hospital wards Predicting the spatio-temporal infection risk in indoor spaces using an efficient airborne transmission model Acknowledgements. We are grateful to Siân Grant for generating figures 1 and 2a and to Raquel González Fariña and Alexander Ramage for many fruitful discussions. We also thank Hugo Macedo, Carina Dos Santos, and Sotiria Tsochataridou from Smart Separations Ltd for valuable discussions.