key: cord-0727727-kfppbq67 authors: White, Dawn; Gu, Jimmy; Steinberg, Catherine-Jean; Yamamura, Deborah; Salena, Bruno J.; Balion, Cynthia; Filipe, Carlos D. M.; Capretta, Alfredo; Li, Yingfu; Brennan, John D. title: Investigation of discordant SARS-CoV-2 RT-PCR results using minimally processed saliva date: 2022-02-18 journal: Sci Rep DOI: 10.1038/s41598-022-06642-5 sha: 5d95d7c1edcf872eb1d5542034e52eb511f85258 doc_id: 727727 cord_uid: kfppbq67 Saliva is an attractive sample for coronavirus disease 2019 testing due its ease of collection and amenability to detect viral RNA with minimal processing. Using a direct-to-RT-PCR method with saliva self-collected from confirmed COVID-19 positive volunteers, we observed 32% false negative results. Confirmed negative and healthy volunteer samples spiked with 10(6) genome copies/mL of heat-inactivated severe acute respiratory syndrome coronavirus 2 showed false negative results of 10% and 13%, respectively. Additional sample heating or dilution of the false negative samples conferred only modest improvements. These results highlight the potential to significantly underdiagnose COVID-19 infections when testing directly from minimally processed heterogeneous saliva samples. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has impacted daily life on a global scale since its emergence in December 2019. Scientists rallied quickly to gather and disseminate information to create sensitive molecular detection methods for SARS-CoV-2 to protect the population 1 . Public health authorities have relied heavily on the "gold standard" reverse-transcription polymerase chain reaction (RT-PCR) testing of nasopharyngeal swabs (NPS). However, this type of sample collection requires professional healthcare workers for procurement, which has prompted researchers to evaluate saliva as a simple, self-collectable specimen. Many studies have shown comparable diagnostic sensitivity for viral genomic RNA extracted from saliva specimens versus NPS when using RT-PCR for COVID-19 detection 2 . To further increase simplicity, several methods, such as the covidSHIELD test developed at the University of Illinois Urbana-Champaign (UIUC) 3 , the SalivaDirect test developed at Yale 4 and the SalivaSTAT method developed at the Medical College of Georgia 5 utilize direct analysis from unprocessed saliva to avoid the RNA extraction step. Our groups are actively involved in the development of a point-of-care antigen test for COVID-19 utilizing minimally processed saliva, which is simply allowed to settle for 5 min followed by dilution of the supernatant by 50% with a buffer, as the specimen 6 . We chose the covidSHIELD RT-PCR processing method to aid in validation of our test due to its relative ease and reported sensitivity. However, it was observed during test development that the inherent complexity of saliva 7 produced a significant number of false negative SARS-CoV-2 RT-PCR results, prompting us to investigate further. University research community provided saliva samples in sterile 50 mL polypropylene tubes following the same self-collection instructions; these samples were aliquoted then frozen or used on the same day as collection. RT-PCR. RT-PCR was performed using the Power SYBR® Green RNA-to-C T ™ 1-step Kit (Fisher Scientific, Ottawa, Ontario, Canada) with the CDC N1 and RNase P forward and reverse primers from Integrated DNA Technologies (IDT: NC, USA). All assessment center and healthy volunteer saliva samples were processed based on the original covidSHIELD method described by Ranoa et al. 3 . Briefly, a 20-50 µL aliquot of the saliva sample was heated at 95 °C for 30 min followed by the addition of an equal volume of 2 × TBE-Tw buffer (100 mM Tris pH 7.5, 90 mM boric acid, 1 mM EDTA, 1% Tween-20). Saliva samples were then incubated at room temperature for 5 min to allow any natural salivary particulates to settle to the bottom of the tube. Fig. S1 ) and the limit of detection obtained with these reaction conditions (see details in Supplementary), a threshold cycle value (C t value) of > 36 was considered negative. Spiking saliva samples with heat-inactivated SARS-CoV-2; heating and diluting saliva samples. Heat-inactivated 2019 Novel Coronavirus (Isolate USA-WA/2020) was purchased from the ATCC through Cedarlane (Burlington, Ontario, Canada). SARS-CoV-2 NPS negative and healthy volunteer saliva samples were spiked with 4.2 × 10 6 genome copies (gc)/mL of heat-inactivated SARS-CoV-2 prior to processing for RT-PCR as described above. Saliva samples that were heated prior to spiking and RT-PCR processing were incubated at 95 °C for 30 min. Saliva samples that were diluted prior to RT-PCR processing were done so with an equal volume of sterile RNase-free water. Prior to assessing saliva samples, calibration curves were generated for three common SARS-CoV-2 genes (N1, E, and RdRp) using either transcribed or extracted viral RNA to create standard curves. However, when SARS-CoV-2-spiked negative saliva samples were tested, amplification with both the E and RdRp primers failed while amplification with the N1 primers produced the expected result, as did amplification of the RNase P gene. Hence, only the N1 gene was tested going forward. We note that Vogels et al. 4 reported a nearly identical observation, in that only the N1 gene, and not the N2, E, or orf1 genes, worked with their SalivaDirect assay. All saliva samples included in this study gave a positive result for the human RNase P internal control using the processing method of the covidSHIELD RT-PCR laboratory developed test 3 (Supplementary Table S1 ). The time between off-site saliva sample collection, and receipt and freezing at the university laboratory (< 72 h) posed no concern with respect to sample integrity. In addition, we did not observe an appreciable difference in RT-PCR C t values when the same saliva sample was tested after a freeze-thaw cycle (see Tables S2 and S3 ). These observations are in agreement with results reported by Herrera et al. 9 and Ott et al. 10 who have reported that saliva samples are stable for up to 15 days at 4 °C 9 and unaffected by a single freeze-thaw cycle 10 . A trial experiment that included Proteinase K as a protective agent against RNA degradation from salivary RNases, as described in Vogels et al., 4 resulted in failed RT-PCR amplification and therefore was not included in the saliva processing protocol (see details in Supplementary Information). To test our workflow and reagents with the covidSHIELD RT-PCR processing method, we initially examined SARS-CoV-2 negative saliva samples (NPS negative) spiked with 10 6 gc/mL heat-inactivated SARS-CoV-2. At this "viral load", a C t value of 29 was expected based on our calibration data ( Supplementary Fig. S1 ). We observed a significant number of RT-PCR negatives (C t value > 36) with the spiked samples when the processed saliva was mixed prior to addition to the amplification mixture (Fig. 1a) . Allowing the same samples to settle improved detection markedly, therefore this settling step was included in all subsequent experiments. All assessment center saliva samples that tested SARS-CoV-2 negative by NPS also tested negative using the RT-PCR method (100% specificity). However, only 15 of the 22 SARS-CoV-2 that were positive for NPS samples also showed a positive result when using the RT-PCR method with the paired saliva sample (68% sensitivity, see Fig. 1b : NPS positive), with an average C t value of 31.7 ± 2.5 and C t range of 26.6-34.3 ( Supplementary Fig. S2 ). We noticed no difference in the rate of RT-PCR success or failure between the wildtype (9 samples) Alpha (10 samples) and Gamma (3 samples) variants that were part of the 22 COVID-19 positive saliva samples ( Figure S2 ). Note that the Delta and Omicron variants were not in circulation in Ontario during the period of patient sample collection. Given that SARS-CoV-2 mutations primarily affect the gene for the Spike protein, rather than the Nucleocapsid protein, amplification of the N1 gene was not expected to be impacted by the presence of variants. The poor solubility led us to question the effect of saliva sample quality (viscosity, particulates) on the test. Physical examination of all the study samples revealed varying viscosity (ranging from water-like to highly viscous with a heterogeneous composition), clarity (clear, cloudy, turbid) and degree of particulate matter (< 10% to > 75% of the sample volume). We evaluated 50 representative SARS-CoV-2 negative saliva samples-from clear and watery to turbid and viscous-by spiking each with 10 6 gc/mL heat-inactivated SARS-CoV-2. Despite having identical "viral loads", these samples showed significant variability in the C t values (average C t value of 31.0 ± 2.2; Supplementary Fig. S2 ) that did not correlate with the physical quality of the sample, suggesting the presence of chemical components that interfered with the assay. We then questioned whether saliva samples collected from assessment center volunteers, who presented with symptoms of SARS-CoV-2 infection or suspected exposure to the virus, caused greater interference than samples from healthy people. A set of 23 healthy volunteer saliva samples were spiked and analyzed as described above. A similar result was obtained wherein three of the samples produced a negative RT-PCR result even after spiking ( Fig. 1b: Healthy volunteer; Supplementary Fig. S2 ) (average C t value of 31.5 ± 1.7; C t range of 28.5-34.1). Saliva is a complex matrix reported to contain unknown RT-PCR inhibitors 11 and RNases that could degrade viral RNA upon release from the capsid 12 (a) Improved detection of spiked saliva samples allowed to settle after processing versus being mixed after processing. Solid black triangles represent samples that became detectable (C t < 36) after settling; dark grey open squares represent samples that showed improved C t values but remained above the cut-off C t value (C t > 36, black dashed line); light grey open circles represent samples that were either detectable in both groups or did not show an appreciable change in C t value. A C t value of 40 represents a negative result. (b) Prevalence of false negative SARS-CoV-2 RT-PCR outcomes using minimally processed saliva samples. The sample number is indicated above the data columns. The percent of false negatives is shown in brackets beside each group. All NPS positive saliva samples were tested as is. All NPS negative and healthy volunteer saliva samples were spiked with 10 6 genome copies/mL heat-inactivated SARS-CoV-2 prior to testing. All samples tested at least in triplicate. See Supplementary Fig. S2 for individual sample C t values. www.nature.com/scientificreports/ results with the spiked saliva samples, four SARS-CoV-2 negative and three healthy volunteer saliva samples that did not respond to spiking were heated at 95 °C for 30 min to denature/degrade salivary interferants prior to spiking and processing as before. Four of the seven samples showed positive C t values (average ΔC t [spikedheated] of 7.9 ± 1.7; C t range of 28.6-32.9) (Fig. 2a) . To determine if chemical interferants could be sufficiently reduced by dilution, which is often used to reduce viscosity 13 and aid with automated sample processing 14 , saliva samples were diluted 50% before the 50% dilution step incorporated in the RT-PCR processing method creating a 25% saliva solution prior to addition to the RT-PCR reaction. The saliva samples chosen for examination were four SARS-CoV-2 positive samples that tested negative using the RT-PCR method and two healthy volunteer samples whose saliva remained negative after spiking with SARS-CoV-2. The SARS-CoV-2 positive samples remained negative after dilution while the two healthy volunteer samples gave positive results, with a reduction in C t value of 7.6 and 6.7 units (Fig. 2b ). This variable drop in C t value with saliva dilution was also observed when the human control RNase P was the RT-PCR target, which in this case was evaluated using a ten-fold dilution to further reduce potential interferants (see Table S4 ). Accurate reporting of COVID-19 infections to monitor populations and control outbreaks has been a primary goal worldwide from the start of the pandemic. Among the various methods currently in use, tests using saliva have the advantage of easy sample acquisition, which could allow collection without a health-care practitioner. However, our study has indicated that minimally processed saliva poses a problem for conventional RT-PCR assays due to complications surrounding its physical attributes (viscosity, heterogeneity) and unidentified chemical constituents. A key observation was that dispersal of saliva particulates via sample mixing prior to the RT-PCR assay increased the number of observed false negative results and increased C t values generally, even in positive samples (Fig. 1a) . Allowing the prepared sample to settle for at least 5 min after processing greatly improved RT-PCR detectability. In our hands, brief centrifugation worked as well as settling ( Supplementary Fig. S3 ), although Ranoa et al. 3 did not observe the same benefit. Based on the visual assessment of several hundred assessment center negative saliva samples including and beyond those used for this study, there was no obvious correlation between any physical attribute and an erroneous RT-PCR result. Furthermore, the rate of false negative results did not seem to depend on the sample group (NPS positive, NPS negative, Healthy Volunteer) ( Fig. 1b; Supplementary Fig. S2 ). Pre-heating of seven saliva samples that consistently returned false negative results after spiking with heatinactivated virus showed marked improvement-four samples returned a positive result (Fig. 2a , black triangles)-suggesting that some inhibitory components in the saliva could be disrupted or degraded. However, the remaining three samples showed resistance to the treatment, and it was unclear why the long heating step already included in the covidSHIELD method was not sufficient for inactivation of the interferants. Sample dilution was unable to produce correct results for false negative saliva samples (NPS positive, saliva RT-PCR www.nature.com/scientificreports/ negative) (Fig. 2b , grey circle and square), though this method did remedy false negative results from spiked healthy volunteer samples. While the utility of saliva as a diagnostic specimen cannot be disputed 15 , and even considering the documented reduction in detection sensitivity relative to NPS samples 16 , our observations provide evidence for a potentially significant issue with a high false negative rate when using minimally processed saliva samples for COVID-19 RT-PCR testing. Indeed, the original manuscript describing the covidSHIELD method 3 reported 11% false negative results upon initial testing, but 100% sensitivity upon retesting; Kandel et al. 17 reported 38 of 432 samples (8.8%) as invalid upon initial testing, improving to three invalid samples after retesting; and Sahajpal et al. 5 reported 5% invalid results (though no false negatives). Our study indicated that valid samples showing expected C t values for the control RNase P sequence could repeatedly result in a false negative SARS-CoV-2 result, suggesting an inherent issue with interferants in some saliva samples. We note that several other factors could lead to variability in saliva samples, such as the timing of sample collection with respect to disease progression, symptoms, and time of day; and the volume of saliva provided. Additionally, the distribution of the virus within the COVID-19 positive NPS samples and matching saliva samples may have differed, as the viral load within different regions of the upper respiratory tract is not necessarily equal or static 18 . We also recognize that disease prevalence in the population at the time of sample collection and our limited number of samples may have contributed to our observations. However, general agreement in the rate of false negative SARS-CoV-2 RT-PCR results across 137 samples from assessment center attendees and healthy volunteers presented here, and seen in other studies, points to unknown factors that produce significant false negative results with a widely used RT-PCR method. These results indicate that while direct use of minimally processed saliva is desirable to increase the simplicity and reduce the cost for COVID-19 testing, the relatively high rate of false negative results may require additional sample processing, such as RNA extraction, to reduce the possibility of COVID-19 positive citizens unknowingly transmitting the virus within the community. Commercialized diagnostic technologies to combat SARS-CoV-2: Advantages and disadvantages Nucleic acid-based diagnostic tests for the detection SARS-CoV-2: An update Saliva-based molecular testing for SARS-CoV-2 that bypasses RNA extraction SalivaDirect: Simple and sensitive molecular diagnostic test for SARS-CoV-2 surveillance SalivaSTAT: Direct-PCR and pooling of saliva samples collected in healthcare and community setting for SARS-CoV-2 mass surveillance High affinity dimeric aptamers enable rapid electrochemical detection of wild-type and B.1.1.7 SARS-CoV-2 in unprocessed saliva Saliva-Friend and foe in the COVID-10 outbreak Real-time PCR-based SARS-CoV-2 detection in Canadian laboratories Saliva is a reliable and accessible source for the detection of SARS-CoV-2 Simply saliva: Stability of SARS-CoV-2 detection negates the need for expensive collection devices Inhibitory effect of salivary fluids on PCR: Potency and removal RNase in the saliva can affect the detection of severe acute respiratory syndrome coronavirus 2 by real-time one-step polymerase chain reaction using saliva samples The reliability of saliva for the detection of SAR-CoV-2 in symptomatic and asymptomatic patients: Insights on the diagnostic performance and utility for COVID-19 screening Challenges in use of saliva for detection of SARS-CoV-2 in symptomatic outpatients Comparison of saliva and nasopharyngeal swab nucleic acid amplification testing for detection of SARS-CoV-2: A systematic review and meta-analysis Sensitivity of nasopharyngeal swabs and saliva for the detection of severe acute respiratory syndrome coronavirus 2 Detection of SARS-CoV-2 from saliva as compared to nasopharyngeal swabs in outpatients SARS-CoV-2 viral load is associated with increased disease severity and mortality B. analyzed the data All data from this study are included in the published article and the Supplementary Information Files.Received: 29 September 2021; Accepted: 3 February 2022 The authors declare no competing interests. The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-022-06642-5.Correspondence and requests for materials should be addressed to Y.L. or J.D.B.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.