key: cord-0727712-ibb7ngk5 authors: Tan, Donald; Yancey, Kristen; Hunter, Jacob B. title: COVID-19 and Otologic Surgery date: 2022-04-28 journal: Oper Tech Otolayngol Head Neck Surg DOI: 10.1016/j.otot.2022.04.004 sha: 0a0733bb08032f77542ba2b2a2617d7c74e62740 doc_id: 727712 cord_uid: ibb7ngk5 In this article, we aim to summarize the impacts of COVID-19 on the practice of otologic surgery. Cadaveric studies have indicated COVID-19 viral particles are present in the middle ear mucosa of infected hosts. Otologic procedures can generate significant amounts of droplets due to reliance on high-speed drills. Multiple guidelines have been developed to improve patient and provider safety peri-operatively. Particle dispersion can be mitigated during microscopic mastoidectomy by utilizing barrier drape techniques. The barrier drape may similarly be applied to the surgical exoscope. Endoscopic techniques have theoretical improved safety benefits by minimizing the need for drilling. The discoveries and innovations borne of the COVID-19 pandemic will lay the groundwork for the practice of otology amidst future pandemics. The Coronavirus Disease-19 pandemic has forced many changes upon the practice of Otolaryngology. In the early days of the pandemic, little was known about the pathogenicity and routes of transmission of the novel virus. In many healthcare settings, the strain of increasing hospitalizations, staffing shortages, and supply chain disruptions led to temporary cessation of elective surgeries. Out of an abundance of caution, several policies and strategies were put into place by Otolaryngologists to balance protecting patients and providers alike from the rapid spread of COVID-19 with providing needed care. At the time of this submission, we lie at a unique juncture in the course of the pandemic. As we look back, we see that the widespread availability of vaccines and testing has obviated the need for many of the restrictions and precautions of early pandemic times. However, as we look forward, emerging variant strains that evade immunity could threaten to undo the progress we have made. In this article, we aim to summarize and discuss techniques and considerations for practicing otologic surgery during uncertain pandemic times like COVID-19, so that we may be prepared to face the emerging pathogens of tomorrow. In March of 2020, the first study of the survivability of COVID-19 on surfaces raised the alarm that this virus was potentially highly transmissible via aerosols and fomites. 1 Around the same time, researchers identified high viral loads within swabs of the nasal passages -raising additional concern for the safe practice of otolaryngology. 2 4 Other post-mortem studies corroborated these findings and additionally found viral particles present in the middle ear without any history of acute otitis media. 5 In a case series by Kurabi et al. of three deceased subjects with detectable viral burden in the nasopharynx, one had middle ear viral load one thousand times lower than the nasopharynx, one had undetectable middle ear viral load, and one had viral load ten times higher than the nasopharynx. 6 Thus, it is reasonable to hypothesize based on the existing evidence that the middle ear harbors COVID-19 particles in living hosts, however there remains a dearth of evidence as to whether these particles are transmissible via instrumentation during otologic procedures. Various guidelines have been proposed during the pandemic to improve the delivery of safe otologic care. [7] [8] [9] One suggestion has been the categorization of otologic surgeries into timeframes of urgency so that cases may be postponed in times of limited healthcare resources or in patients with active infection. George While these guidelines may have limited applicability in various practice settings, they remain useful considerations to support the decision making of practicing otolaryngologists. Literature from the early pandemic showed that endonasal instrumentation is sufficiently aerosol generating that it poses a transmission risk to the operating room staff. 10 Operating under the assumption that the middle ear mucosa can host live viral particles, researchers have aimed to quantify the dispersion of particles during mastoidectomy to estimate the risk of intraoperative aerosol generation. In a literature review by Favre et al., six experiments aimed at describing particle spread during mastoidectomy were identified: four cadaveric, one live subject, and one plastic model. There was significant variation in experimental design, methodology, and primary outcomes that limited comparisons of the studies. In two of the six studies fluorescent droplets were detected up to two meters away from the drilling site. Two studies reported direction of spread as an outcome measure and indicated that particles were mostly directed towards the surgeon yet present in all directions, implying risk to all intraoperative staff. They concluded that future studies are needed to determine the effects of burr type/size, and drill speed on particle dispersion. As it stands, mastoidectomy results in significant particle spread due to high-speed drilling. It remains undetermined whether viral particles exist within the dispersed particles, whether virus-containing aerosols are additionally generated, and how the risk of viral transmission during mastoidectomy compares to endonasal high-speed drilling given the suggested difference in viral load between the subsites. A unique pandemic era challenge of using the operating microscope is the limited ability to wear PPE while maintaining an adequate field of view. There is an inverse relationship between the surgeon's distance from the microscope and the resultant field of view. A recent study of various combinations of masks and eye protection showed that all goggles and face shields, as well as certain bulkier N95 masks decreased the operator's field of view. 11 In the most dramatic example, concurrent use of a N95 mask and visor face-shield decreased the visible target area from 100% without PPE to only 4%. Due to the concern for aerosolization of viral particles with powered instruments combined with the limited ability of the surgeon to wear adequate PPE, investigators began to experiment with methods of particle mitigation during mastoidectomy. Several studies have focused on the use of various surgical drapes to create a barrier between the operative site and the microscope. [12] [13] [14] [15] [16] [17] [18] The basic principle involves using a sterile drape connected to the microscope to create a tent-like enclosed space over the operative site, aptly named OtoTents (Fig 1) . 18 Chari et al. performed a head-to-head cadaveric study comparing a drape made from a 1060 Steri-Drape (3M) and a custom drape with arm ports they designed with Grace Medical. 18 The 1060 drape is an opaque square shaped sterile drape with adhesive in the center that is most commonly utilized in Ophthalmology procedures. 15 The 1060 drape OtoTent may allow for aerosol escape during arm movements because the surgeon's arms are placed under rather than through the drape (Fig 1) . In their study they had the least aerosolization with the custom drape (Fig 2) with the addition of a second suction near the operative site (Fig 3) and delayed removal of the drape after drilling to allow for settling of airborne particles. In another cadaveric study, Chen et al. demonstrated that their modified 1060 drape OtoTent was inexpensive and quantitatively reduced particle dispersion beyond the boundaries of the drape. 15 Their modification involved securing the drape posteriorly between the surgeon's arms with tape. They additionally suggest in the operating room, the drape may be secured circumferentially with staples and arm ports created by incising the drapes, although this was not tested in their experimental design. Carron et al. reported they were able to fashion OtoTents out of clear drapes that were readily available at their institution. 13 Utilizing a Steri-Drape 1015 (3M), the C-Armor (Tidi), or Sterile-Z Back Table Cover (Tidi) they found that larger transparent drapes make it easier for the surgical technician to safely pass instruments into the field (Fig 4,5) . Cottrell et al. demonstrate an OtoTent fashioned from a Genesys C-Arm/Mobile X-Ray drape as well as a video tutorial for assembly: https://doi.org/10.1186/s40463-020-00471-0. 16 Many variations of the OtoTent exist, but they are largely untested in the clinical setting. However, several points of observation can be made from the existing evidence. As the basic function is easy to approximate, for most providers the best drape material is probably the one that is readily available. Transparent drapes are advantageous over opaque drapes as they allow the surgeon and surgical technician better visualization of the field. Incorporating a Mayo stand within the drape with commonly used instruments limits manipulation of the drape. A second scavenger suction positioned near the operative site can mitigate particle dispersion. Adding povidone iodine to the irrigation solution is simple, inexpensive, theoretically virucidal, produces minimal discoloration, and has not been shown to be ototoxic. 19 Placing the surgeon's arms through the drapes rather than under the drapes may limit escape of aerosols. Delaying removal of the drape after completion of drilling minimizes release of airborne particles. Although the risk of viral transmission during mastoidectomy remains unknown, these measures remain options for consideration when an abundance of caution is indicated. The exoscope is an extracorporeal digital telescope that provides 3-D visualization by viewing a special HD monitor with polarized lenses. This allows for a two-handed surgical technique that is more ergonomically favorable than the traditional microscopic approach. 20 In the pandemic era, exoscopes are theoretically advantageous as they are compatible with OtoTent type draping but do not have significant limitations in the visual field when wearing PPE. The 3-D lenses can be modified to be applied to the outside surface of a face-shield or respirator so long as care is taken to maintain the correct polarity of the "front" and "back" of the lenses. 17, 21 Gordon et al. suggest adding a Leyla holding rod or anesthesia circuit holder tree opposite the exoscope and securing the drape tautly to it to create more space. 21 The previously mentioned considerations for microscopic mastoidectomy should also theoretically apply to exoscopic mastoidectomy. Another valid strategy to mitigate the risk of aerosolization during mastoidectomy is to minimize drilling via the trans-canal endoscopic approach when clinically appropriate. Like exoscopic surgery, endoscopic surgery is similarly ergonomically favorable. 20 A cadaveric study comparing droplet spread during endoscopic drill atticotomy, microscopic drill atticotomy, and cortical mastoidectomy demonstrated a significant 4.5-fold reduction in droplet generation between endoscopic and microscopic atticotomy and a 62-fold reduction between endoscopic atticotomy and cortical mastoidectomy. 22 No literature currently exists regarding the usage of drape barrier systems when using powered instruments in endoscopic ear surgery, however the basic ideas of adapting a containment system should theoretically apply. It remains uncertain if COVID-19 is transmissible during otologic surgery in the same way it has been shown for endonasal surgery. Cadaveric studies suggest COVID-19 viral particles can be present within the middle ear mucosa. Certain otologic surgeries, mastoidectomy especially, are aerosol generating by nature. A variety of strategies have been proposed to enhance the safety of otologic surgery during a pandemic. Guidelines exist to assist with triaging surgical cases and clinic visits. Various techniques have been proposed to minimize intraoperative dispersal of aerosolized viral particles, although they are largely untested in the clinical setting. Endoscopic and exoscopic surgery offer favorable ergonomics and do not limit the surgeon's ability to wear PPE. These innovations borne in times of extreme uncertainty will serve as the groundwork for the future of Otology as the COVID-19 pandemic continues to evolve, and we prepare for the pandemics of the future. The authors report no proprietary or commercial interest in any product mentioned or concept discussed in this article. Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 Undetectable viral load within the mastoid during cochlear implantation in a patient with COVID-19 COVID-19 sampling from the middle ear and mastoid: A case report SARS-CoV-2 Virus Isolated From the Mastoid and Middle Ear: Implications for COVID-19 Precautions During Ear Surgery. JAMA otolaryngology--head & neck surgery Evidence of sars-cov-2 virus in the middle ear of deceased covid-19 patients Immunohistochemical and qPCR Detection of SARS-CoV-2 in the Human Middle Ear Versus the Nasal Cavity: Case Series. Head and Neck Pathology Proposal of a timing strategy for cholesteatoma surgery during the COVID-19 pandemic American Otological Society, and American Academy of Otolaryngology -Head and Neck Foundation Guide to Enhance Otologic and Neurotologic Care During the COVID-19 Pandemic. Otology & neurotology : official publication of the American Otological Society A Commentary on Safety Precautions for Otologic Surgery during the COVID-19 Pandemic. Otolaryngology -Head and Neck Surgery (United States) Endonasal instrumentation and aerosolization risk in the era of COVID-19: simulation, literature review, and proposed mitigation strategies The challenge of performing mastoidectomy using the operating microscope with coronavirus disease 2019 personal protective equipment (PPE) Two-drape closed pocket technique: minimizing aerosolization in mastoid exploration during COVID-19 pandemic A Simple Technique for Droplet Control During Mastoid Surgery Mitigation of Particle Spread During Mastoidectomy: A Systematic Review Demonstration and Mitigation of Aerosol and Particle Dispersion During Mastoidectomy Relevant to the COVID-19 Era An operative barrier system for skull base and mastoid surgery: Creating a safe operative theatre in the era of COVID-19 Exoscope-assisted Otologic Surgery During the COVID-19 Pandemic Aerosol Dispersion During Mastoidectomy and Custom Mitigation Strategies for Otologic Surgery in the COVID-19 Era. Otolaryngology -Head and Neck Surgery (United States) 0.5% povidone iodine irrigation in otorhinolaryngology surgical practice during COVID 19 pandemic Heads-up Surgery: Endoscopes and Exoscopes for Otology and Neurotology in the Era of the COVID-19 Pandemic Exoscope and Personal Protective Equipment Use for Otologic Surgery in the Era of COVID-19 Quantification and Comparison of Droplet Formation During Endoscopic and Microscopic Ear Surgery: A Cadaveric Model. Otolaryngology -Head and Neck Surgery (United States)