key: cord-0724120-fj4kl4au authors: Malanchini, G.; Ferrari, P.; Leidi, C.; Ferrari, G.; Racheli, M.; Senni, M.; De Filippo, P. title: Ventricular arrhythmias among patients with implantable cardioverter‐defibrillator during the COVID‐19 pandemic date: 2021-02-16 journal: J Arrhythm DOI: 10.1002/joa3.12518 sha: 0fdd8dadce82e3ffb6075979a24ac74cf62d31ce doc_id: 724120 cord_uid: fj4kl4au BACKGROUND: Coronavirus Disease‐2019 (COVID‐19) has been associated with myocardial injury and higher risk of arrhythmic complications. However, no reports are available about the effect of the ongoing pandemic on arrhythmias in patients at risk. OBJECTIVE: To describe the effect of COVID‐19 pandemic on arrhythmic burden among high‐risk patients. METHODS: This is a cross‐sectional study on the incidence of ventricular arrhythmia (VA) during the pandemic outbreak (study period), compared to the same timeframe in 2019 (reference period). Inclusion criteria were age (>18 years) and having an implantable cardiac defibrillator (ICD). RESULTS: Among 455 patients enrolled (mean age 64.9 ± 15.7 years; 25.1% females and 39.6% with CRTD), in the study period, 45 (9.9%) patients experienced a total of 86 VA; 8 patients (1.7%) required antitachycardia‐pacing (ATP) and 6 (1.3%) at least one shock. In the reference period, a total of 69 events occurred in 36 patients (7.9%). Six patients (1.3%) required ATP and three (0.7%) at least one shock. The number of patients that suffered from any arrhythmic events in the study period (9.9% vs 7.9%) did not significantly differ from the reference period (χ(2) = 1.09, P = .29). The main predictor of VA during the COVID‐19 pandemic was the previous history of any ICD therapy (OR = 3.84, P < .001). CONCLUSIONS: No evidence of an increase of arrhythmic burden was found during the COVID‐19 pandemic among patients with an ICD. Previous studies have reported seasonal variation, associated with influenza-virus spread, in the occurrence of ventricular arrhythmias (VA) in patients with an implantable cardiac defibrillator: during high influenza activity periods, patients were more likely to have a VA treated with shock or antitachycardia pacing (ATP). 10, 11 There is a substantial lack of data from a wider population with the history of cardiac diseases on the possible arrhythmogenic effects of the COVID-19 pandemic. The current study aims to: (a) Characterize the burden of ventricular arrhythmia attributable to COVID-19 among patients with an ICD during the pandemic outbreak in Italy, focusing on the period between February 21st and April 5th, 2020; and (b) Compare the incidence of VA during the COVID-19 outbreak to that observed during the same timeframe the previous year (February 21st and April 5th, 2019). This was a cross-sectional comparative study conducted at the Electrophysiology and Cardiac Pacing Unit at ASST Papa Giovanni XXIII Hospital, Bergamo, Italy. The study period was selected based on the epidemiology of the COVID-19 pandemic in the area, 5 from February 21st to April 5th, 2020. As a reference period, we selected the same timeframe during the previous year (February 21st -April 5th, 2019). Inclusion criteria were age (>18 years) and having an implantable cardiac defibrillator (ICD), a subcutaneous ICD (S-ICD), or cardiac resynchronization therapy defibrillator (CRT-D). All patients were enrolled in different remote monitoring systems, according to manufacturer technology (BIOTRONIK Home Monitoring, Boston Scientific LATITUDE, and Medtronic CareLink), which allows physicians to access on a secured website to patients' data. Patients were considered eligible for analysis if available device stored data covered at least 1 month within the study period. Data from the remote-monitoring system were deidentified before analysis. Patient population was characterized using demographic data including age, gender, device model, reason for implantation, previous history of antitachycardia therapy (shocks or ATP), antitachycardia programming. Among 839 patients with an implanted cardiac device followed up with remote monitoring at the enrolling Institution on April 5th, 2020, 563 had ICD, S-ICD or CRT-D. We excluded 26 patients due to: limited follow-up during the study timeframe (21 patients) , unavailable data at remote monitoring (5 patients) or implantation after the study period (77 patients, see Figure 1 ). The final cohort consisted of 455 patients. The diagram shows the study population's selection process; ICD, implantable cardioverter-defibrillator; CRTD, Cardiac resynchronization therapy-defibrillator; S-ICD, subcutaneous implantable cardioverter-defibrillator; PPM, permanent pace-maker; CRTP, cardiac resynchronization therapy-pacemaker; ICM, implantable cardiac monitor The study was approved by the institutional review board at the enrolling Institution. Every participant gave informed consent for such analysis during hospitalization for device implant or replacement. The main endpoint of the study was an episode of ventricular tachycardia (VT) or ventricular fibrillation (VF) during the study period (see Supplementary Material). Programming of detection zones, counters, and discrimination algorithms was set in any patient according to indication, routine practice, and patient's history. Device detected ventricular episodes labeled as VT or VF was adjudicated by two expert cardiac electrophysiologists; in case of discordance a third electrophysiologist was asked to classify the event and the episode was labeled according to the majority vote. Episode data were categorized into binary variables, indicating the presence or absence of a VT, VF, treatment with ATP or with shock during the study period. Data analyses were conducted separately for VA episodes self-terminating and/or treated with ATP or with at least one shock. Descriptive statistics for continuous variables were reported as mean (standard deviation) and binary variables as percentages. The event rate was calculated as the number of patients having an event in the study period divided by the total number of patients. Event rate in the study period was compared to that of the reference period using chi-squared test. The mean number of events in the study period was calculated as the total number of events divided by the total sample size; comparison between periods was carried out by t t test. Univariate and multivariate logistic and linear regressions were conducted in order to examine the associations between variables of interest and the occurrence of an arrhythmic event. In a subgroup of patients, with available data, we also consider physical activity level and heart rate data and compare them to reference period. For all tests, a significance level of 0.05 was used. All analyses were performed using the Stata software version 13.0 (StataCorp, Texas, US). As depicted in Figure 1 , the final cohort consists of 455 patients; mean age was 64.9 ± 15.7 years. 24.3% of them were females. Overall, 45 (9.9%) patients experienced from February 21st to April 5th, 2020, a total of 86 VA: 77 episodes (89.5%) of VTs, 9 (10.5%) VF. Eight patients (1.7%) required ATP and six (1.3%) at least one shock during the study period (see Table 1 ; Figure 2 The number of patients that suffered from any arrhythmic event did not differ significantly from that of the reference period (χ 2 = 1.09, P = .29). A comparable rate of VT, VF, ATP, and shocks was also found ( Table 2 ). The overall mean event number per person during the timeframe of the study was 0.19 events/person, not significantly higher than 0.15 events/persons in the reference period (difference 0.04, P = .36). The main predictor of any VA during the COVID-19 pandemic period was a previous history of any ICD therapy (OR 3.54, P < .001) and recent (<12 months) history of ICD interventions either with ATP or shock (OR 9.15, P < .001). Age, sex, pharmacologic therapy or secondary prevention indication were not found to be predisposing factors for arrhythmic events during the study period (Table 3 -uni- variable and multivariable logistic regression analysis). Among men, the incidence of VA was similar in the study period to the reference period (34 vs 26 events in a sample of 342 males, χ 2 = 0.034, P = .851). The findings were consistent in univariable and multivariable linear regression analysis (Tables S1-S4). However, only a small minority of patients had malignant and fatal cases of such complications. No data are available on the cardiac effect of COVID-19 spread among the general population and especially in patients with heart disease. We hypothesized that subjects with an ICD could be the subgroup at higher risk of arrhythmic manifestation of such a pandemic. It is important to underscore that the Italian area considered in the study, is one with the highest rate of infection and death for COVID-19, 13,14 thus a population-based approach could be considered highly informative. Since recent reports of higher incidence of cardiac arrest during the COVID-19 period, also underscore that the rhythm of the presentation was more likely to be asystole or pulseless electrical activity than ventricular rhythms, 15 our study reinforces the concept that ventricular event is as likely as in previous periods of time. Considering that hospital reports of cardiac abnormalities among patients with COVID-19 are limited to subjects admitted to the intensive care unit (ICU), it is unclear how important is the impact of cardiovascular complication among nonhospitalized patients. The presence of myocardial damage, eg, elevated cardiac troponin, in patients with COVID-19 is reported as independent factors associated with mortality, 16 but there is a substantial possibility that the overestimation of cardiac involvement in such a condition maybe attributed to studies focusing on very sick patients admitted to ICU with COVID-19. So that, cardiac involvement maybe less severe among asymptomatic and mildly symptomatic cases, that are missing from most reports. A growing body of recently published evidence found that seasonal influenza pandemics could trigger acute coronary syndromes and arrhythmias. 10, 11, 17 Therefore, it has also been proposed that the increment of underlying cardiovascular diseases may not be specific to COVID-19, but a more general feature of seasonal viral infections. The International community is giving high priority to support cardiological practice in a setting of the disruption of previously defined protocols, and, thus, knowledge of epidemiological data is of seminal relevance. [18] [19] [20] Previous reports underscore the importance of device derived data analysis in monitoring the activity level of ICD patients, 21 the present study confirms the sensible reduction of activity level during the pandemic. The present study showed that, among the unselected consecutive population of patients with an ICD, in a setting of high incidence of disease caused by SARS-CoV2, 22 the rate of ventricular arrhythmias was not significantly higher. Possible speculative hypothesis of the stable incidence in the two periods maybe also be related to relatively stable conditions of cardiac patients at the very beginning of the disruptive changing in health-care providing that occurred in the period, which may become more relevant in the subsequent months and years. 23 Continuous monitoring of the phenomenon will give in the future more information about the effect of the COVID-19 pandemic on cardiac health, including arrhythmic burden. A number of limitations should be considered. First, the study approach does not allow us to verify the actual incidence of clinically relevant COVID-19 in the cohort. Nevertheless, our approach allowed us to verify the phenomenon in a large sample and to account for the effect of asymptomatic infections in one of the areas most affected by the COVID-19 pandemic. Furthermore, our approach allowed us to assess the impact of the pandemic from a holistic standpoint, which goes beyond the sole effect of viral activity. Second, we considered only patients with an ICD implanted, generally because considered at higher risk of ventricular arrhythmia due to underlying cardiac disease; this group may be one of the more carefully followed-up by cardiologists and device specialists, as suggested by the high proportion of antiarrhythmic drugs taken by patients in the study. Fourth, we were unable to assess whether all patients suffering from COVID-19 were treated with the same pharmacological and nonpharmacological therapy. The current study found that the incidence rate of any ventricular arrhythmia during the first 45 days of the COVID-19 pandemic outbreak was 9.9% and only a minority of patients required therapy from ICD. There was no evidence of a significant increase in the arrhythmic burden during the study period if compared to the same period in the previous year. The main predictor of arrhythmic events was the previous history of any device therapy, especially within the previous 12 months. All authors report no conflict of interest. G. Malanchini https://orcid.org/0000-0002-5044-0069 Cardiac and arrhythmic complications in patients with COVID-19 Guidance for cardiac electrophysiology during the coronavirus (COVID-19) pandemic from the Heart Rhythm Society COVID-19 Task Force; Electrophysiology Section of the American College of Cardiology; and the Electrocardiography and Arrhythmias Committee of the Council on Clinical Cardiology Association of cardiac injury with mortality in hospitalized patients with COVID-19 in Wuhan Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirusinfected pneumonia in Wuhan Baseline characteristics and outcomes of 1591 patients infected with SARS-CoV-2 admitted to ICUs of the Lombardy Region ACC/AHA/HFSA focused update of the 2013 ACCF/ AHA guideline for the management of heart failure: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure Society of America ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: The Task Force for the Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC) AHA/ACC/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) developed with the special contribution of the Heart Failure Association (HFA) of the ESC Effect of high influenza activity on risk of ventricular arrhythmias requiring therapy in patients with implantable cardiac defibrillators and cardiac resynchronization therapy defibrillators Seasonal trend of ventricular arrhythmias in a nationwide remote monitoring database of implantable defibrillators and cardiac resynchronization devices Clinical features of 85 fatal cases of COVID-19 from Wuhan: a retrospective observational study The response of Milan's Emergency Medical System to the COVID-19 outbreak in Italy At the epicenter of the Covid-19 pandemic and humanitarian crises in italy: changing perspectives on preparation and mitigation Characteristics associated with out-of-hospital cardiac arrests and resuscitations during the novel coronavirus disease Potential effects of coronaviruses on the cardiovascular system: a review ESC guidance for the diagnosis and management of CV disease during the COVID-19 pandemic Cardiovascular considerations for patients, health care workers, and health systems during the coronavirus disease 2019 (COVID-19) pandemic Urgent pacemaker implantation rates in the Veneto Region of Italy after the COVID-19 outbreak Impact of the coronavirus disease-19 outbreak on physical activity of patients with implantable cardioverter defibrillators The impact of the COVID-19 pandemic on cardiology services