key: cord-0722399-mxgdifom authors: Singh, Lavanya; Anyaneji, Ugochukwu J.; Ndifon, Wilfred; Turok, Neil; Mattison, Stacey A.; Lessells, Richard; Sinayskiy, Ilya; San, Emmanuel J.; Tegally, Houriiyah; Barnett, Shaun; Lorimer, Trevor; Petruccione, Francesco; de Oliveira, Tulio title: Implementation of an efficient SARS-CoV-2 specimen pooling strategy for high throughput diagnostic testing date: 2021-09-07 journal: Sci Rep DOI: 10.1038/s41598-021-96934-z sha: 2513d35c421d3f93cedbbb9aad41e7412c9d0906 doc_id: 722399 cord_uid: mxgdifom The rapid identification and isolation of infected individuals remains a key strategy for controlling the spread of SARS-CoV-2. Frequent testing of populations to detect infection early in asymptomatic or presymptomatic individuals can be a powerful tool for intercepting transmission, especially when the viral prevalence is low. However, RT-PCR testing—the gold standard of SARS-CoV-2 diagnosis—is expensive, making regular testing of every individual unfeasible. Sample pooling is one approach to lowering costs. By combining samples and testing them in groups the number of tests required is reduced, substantially lowering costs. Here we report on the implementation of pooling strategies using 3-d and 4-d hypercubes to test a professional sports team in South Africa. We have shown that infected samples can be reliably detected in groups of 27 and 81, with minimal loss of assay sensitivity for samples with individual Ct values of up to 32. We report on the automation of sample pooling, using a liquid-handling robot and an automated web interface to identify positive samples. We conclude that hypercube pooling allows for the reliable RT-PCR detection of SARS-CoV-2 infection, at significantly lower costs than lateral flow antigen (LFA) tests. Reverse-transcription real-time polymerase chain reaction (RT-PCR) testing is the gold-standard technology used for SARS-CoV-2 diagnosis. This test can cost up to US$ 56 (ZAR 850) per test, making high-throughput RT-PCR testing of every individual impractical. Sample pooling offers an attractive solution. By combining samples and testing them together, instead of performing individual tests, one can significantly reduce the number of tests and the associated labour and consumable costs. This method was first proposed by Dorfman 10 in 1943. Hypercube pooling, developed by Mutesa et al. 11 , requires even fewer tests and yields greater cost savings. For example, at viral prevalences p < 0.05%, hypercube pooling yields a 100-fold cost-reduction as opposed to a 22-fold for Dorfman's algorithm. Hypercube pooling therefore offers a highly affordable means of testing large numbers of samples. We also describe a quantitative cost comparison with lateral flow antigen (LFA) tests, finding hypercube pooling to have a significant cost advantage at low viral prevalence (Supplementary Information-Cost comparison of hypercube-based pooled tests vs. lateral flow antigen tests). Hypercube pooling has been eloquently explained in the literature 11 . Briefly, the samples to be tested are divided into equally sized subsamples which are pooled together according to a mathematical algorithm. Here we report on pooled testing methods which can uniquely identify infected samples among groups of 27 and 81 samples (using 3-and 4-dimensional hypercubes, respectively), in far fewer than 27 or 81 tests. If the group is negative, then all individual samples in that group are deemed negative. If a group is positive, then its sub-samples are recombined in the form of slices within the hypercube corresponding to different overlapping sub-pools. Groups of 27 or 81 samples are sub-pooled into 9 and 12 slices respectively, each consisting of 9 or 27 subsamples respectively. Each individual sample is then represented in 3 or 4 different slices respectively, and the test results for the slices can be used to infer which sample is positive, based on its consistent detection within each of the hypercube slices, without an individual test ever being required. The slicing patterns for these groups are shown in the Supplementary Information Tables S1 and S2 and the complete workflows are presented in Fig. 1 . Although the pooling strategy described above offers considerable benefits over individual testing, it does involve tedious and repetitive pipetting steps, which can be cumbersome when performed manually and can raise the risk of human error. For example, a 3-d hypercube involves 108 precise pipetting steps in different combinations, i.e., a group-level pool of 27 sub-samples plus 9 slice-level sub-pools of 9 sub-samples each. The is contained in a group of 27 samples or, respectively, 81 samples; (B) 9 (resp. 12) slice pools, each consisting of 9 (resp. 27) sub-samples, are created using a liquid handling robot; (C) RNA extraction is done on the group pool of 27 (resp. 81) samples (1 reaction) and 9 (resp. 12) slice pools (9 or 12 reactions); (D) qPCR results are positive for the group of 27 (resp. 81) samples and the respective slices 1, 4 and 8 (resp. 1, 4, 7, and 11); (E) De-bundling software is used for the automatic determination of the positive sample in the hypercube and for generating individual diagnostic reports. This open source robotic platform lends itself to scalability and rapid deployment. The OT2 is modularly constructed and utilises widely available non-proprietary electronic components that are neither difficult nor expensive to repair or replace. Flexibility is offered through the Python Application Programming Interface (API), which simplifies custom protocol development. The additional laboratory automation described here, refers to the automatic determination of the individual positive result(s) and the de-bundling (or ungrouping) of pooled results into individual results using an automated web interface. The advantages of automated sample pooling include increased human-resource time (which can be better allocated for data analysis, experimental setup, etc.), the elimination of the possibility of human error (due to fatigue or distraction, for example), the reduction of costs associated with manual labour, and the flexibility to easily replicate or modify protocols based on the starting number of samples and desired pooling strategy. A-C), in which a single positive sample is diluted up to 27-fold, are shown in Fig. 2 . The plots are based on the Ct scores obtained for each of the three target genes (Supplementary Information Table S3 ). The results show that the positive samples for each experiment can be successfully amplified and detected in the pool containing 27 samples and in each of the positive slices containing 9 samples each. A-H), in which a single positive sample is diluted up to 81-fold, are shown in Fig. 3 . The plots are based on the Ct scores obtained for each of the three target genes (Supplementary Information Table S4 ). The operational sensitivity of the pooled test procedure is decreased for samples with an initial (undiluted) Ct value exceeding 32 as indicated by experiments D and H, where amplification in the 81-pool samples was not successful (none of the target genes were detected). Efficiency-number of tests saved using the pooling method. We received approximately 121 samples per week over an 8 week period, for testing (i.e. 968 individual samples in total). Each week, three groups of Laboratory automation. We created an automated and easy-to-use web interface to assist in the de-bundling of pooled testing results and the identification of the positive sample(s) found in a pool. The de-bundling module requires as input the analysis file generated from the pooled testing results and a list of sample identifiers. It produces a de-bundling report, which can be easily integrated into a laboratory information management system (LIMS) such as LabWare 7 (used in our laboratory), for individual result reporting. To infer the positive sample, the user specifies the pool size, i.e. 27 or 81, the number of positive slices and their respective slice numbers. The application then uses this information to determine and output individual positive test results. Both applications, freely available at http:// krisp2. ukzn. ac. za: 8080/ rega-pooli ng/ pooli ng (Supplementary Information Figure. S3), were used for all the analysis and reporting of results described in this paper. Diagnostic detection of SARS-CoV-2 is crucial for managing the pandemic 12, 13 . The early identification and isolation of SARS-CoV-2 infected individuals remain a key strategy to interrupt community transmission. In this pilot study, we have successfully implemented hypercube pooling for frequent testing of a professional sports team. We show that this procedure reliably detects a single positive sample in a group of 81, provided the starting sample has a Ct ≤ 32. Whilst there is a need for further evaluation, particularly with samples with a wider range of Ct values and pools with multiple positive samples for different viral prevalence scenarios, these results indicate that the pooling strategy is indeed a promising approach for cost-efficient RT-PCR testing. Other studies have demonstrated the successful implementation of pooled testing using groups of up to 5 and 8 samples each 8 . To our knowledge, this is the first study that has implemented the SARS-CoV-2 hypercube-based pooled testing strategy, using group sizes as large as 81. We selected for analysis samples with Ct values that are typical for the population under study. For comparison, we also selected samples with Ct values that are one standard deviation away from the mean Ct value. We used historical data from the population of samples tested routinely in KZN to determine the distribution of Ct values present at various percentile ranges (Supplementary Information Figure S1 ). The asymmetrical (leftskewed) distribution of the data may be attributed to the population of samples that was used to generate the curve i.e. symptomatic people with active disease (and therefore lower Ct scores) presenting at health facilities. The retention of the sensitivity of the pooled test procedure as the hypercube dimension size (and consequently the dilution) increases is an obvious concern. Our results demonstrated no loss of assay sensitivity for samples with an initial (undiluted) Ct value ≤ 32 (Fig. 3) . Samples with higher Ct values would typically have a lower viral load, which may be deemed as clinically and / or epidemiologically insignificant, since the infection is not likely to be contagious (a cut-off Ct > 30 can be associated with non-infectious samples) 14 . Propagating SARS-CoV-2 from clinical samples can also be used as a valuable proxy for infectiousness. There are however, conflicting reports on the cut-off Ct value at which the virus is not cultivable, which can range 15, 16 . In any event, high Ct values are expected to be associated with low infectivity 17 ; the maximum viral load occurs during the onset of symptoms, when the risk of transmission is highest 18 . In respiratory samples, the viral load is highest during the initial stage of infection (patients in the early stages of infection usually have Ct values of 20-30 or less 16 ), and reaches a peak in the second week, and then falls 19 . The pooling strategy we have implemented is therefore most beneficial for detecting asymptomatic or presymptomatic people who are on the viral load incline. In addition, the effects of the loss of assay sensitivity can be mitigated by implementing more frequent testing-a solution which could be more easily afforded given the demonstrated cost savings of the pooled testing strategy. There have also been reports of inherent inaccuracy due to higher false negative rates associated with the pooled testing method 20 . Our method however, includes many consistency checks. For example, the detection of a single positive pool (corresponding to a hypercube slice) when all other pools are negative is indicative of a testing error 11 . This is especially beneficial when compared to approaches such as binary pooled testing 21 which relies on repeated, sequential testing of the positive sample, and a single negative test can prematurely terminate the sequence of tests leading to a false negative result. Another cause of false negative results is sequence variation at primer or probe binding sites on the viral RNA 22 . In South Africa, a new SARS-CoV-2 lineage (501Y.V2) characterised by various mutations in the spike (S) gene has been reported 3 . However, there was no apparent loss of sensitivity for the S-gene in the RT-PCR assay used in this study. We have developed and successfully implemented a pilot SARS-CoV-2 pooled testing strategy for a prominent South African rugby team. The successful implementation of pooled testing requires that 3 important criteria are met viz. (i) efficiency, (ii) sensitivity and (iii) operational feasibility 8 . Our study was successful in satisfying each of these criteria. Firstly, we achieved a > 40-fold gain in testing efficiency, and a corresponding reduction in cost, compared to individual testing. The cost reduction is most impressive when all individuals are negative, because 27 or 81 different samples can be determined to be negative by using just one qPCR reaction, in a 3-d or 4-d hypercube, respectively. This was the case with the screening of a South African rugby team at the KRISP laboratory, where, during the first 8 weeks, all of the samples were tested using hypercubes of sizes 27 or 81, and found to be negative. Only from the 9th week was an additional round of slice testing required. Secondly, no significant loss of sensitivity for samples with appreciable viral loads (Ct ≤ 32) was observed. Thirdly, we validated our pooling workflow, i.e., by using liquid-handling robots to automated sample pooling and software applications to automate the identification of positive samples. There are more conventional methods for high-throughput diagnostic testing which are available. For example, SARS-CoV-2 lateral flow antigen (LFA) tests are point-of-care rapid tests that can be used for large-scale screening. Although LFAs may be appealing because they are cheap, since they do not require a laboratory with specialized equipment or personnel and can provide results in 15-30 min, they do present some limitations; the sensitivity of this type of technology can vary considerably around an average sensitivity of 56.2% (95% CI 29.5 to 79.8%) 23 , thereby decreasing its utility in screening certain populations such as health-care workers and other front-line personnel. We have performed a detailed cost comparison of the hypercube-based pooled testing strategy compared to the LFAs. We estimate that at prevalences below 0.43%, it costs over 6 times more to achieve the reliable detection (i.e. a detection probability of at least 99.9%) of SARS-CoV-2 infectious individuals by using LFAs compared to hypercube testing (Supplementary Information-Cost comparison of hypercube-based pooled tests vs. lateral flow antigen tests). Despite their higher cost for reliable detection, LFAs may be used to complement hypercube-based testing, particularly when quick results are needed and the lower sensitivity of the assay is not considered problematic. The pooled testing strategy and downstream automation protocol described in this study have together led to a significant reduction in cost, kit usage and turnaround time in our laboratory. While we demonstrated its successful application for frequent testing of a professional sports team, this approach can potentially be applied for screening other low prevalence, asymptomatic population groups. Further evaluation of this approach in different populations and epidemic settings is desirable. Laboratory, University of KwaZulu-Natal, is to extract viral ribonucleic acid (RNA) from nasopharyngeal and / or oropharyngeal swab samples. This is followed by RT-PCR (TaqPath COVID-19 CE-IVD RT-PCR kit, Ther-moFisher Scientific, MA, USA) for the detection of three SARS-CoV-2 target genes (viz. S-gene, N-gene and ORF1ab). A sample is considered "positive" if at least 2 out of the 3 target genes are amplified with an abovebackground fluorescence signal, cycle threshold, Ct ≤ 40 PCR cycles. A sample is considered "inconclusive" if 1 out of the 3 target genes is positive (Ct ≤ 40) and should then be repeat tested. A sample is considered "negative" if none of the 3 target genes is amplified. Swab samples collected in viral transport medium (VTM) for routine SARS-CoV-2 surveillance in KwaZulu-Natal, South Africa were used in this study. All experiments were conducted in accordance with relevant local guidelines and regulations. Historical data from a population of approximately 1200 samples tested routinely in KZN was used to determine the distribution of Ct values present at various percentile ranges (Supplementary Information Figure S1 ing tests to evaluate proof-of-concept and determine whether these samples would still result in successful PCR amplification when diluted 27-(in group-level pools) and 9-(in slice-level pools) fold using 3-d hypercubes. First, for each positive sample, a group-level pool containing 27 samples was created. Each positive sample was combined with 26 negative swab samples as follows: sample tubes were labelled from 1 to 27. Samples were added to each of the labelled tubes, with the positive sample inserted blindly, i.e. in a position of the hypercube not known to the person performing the pooling experiments or the analysis of results. Each sample was vortexed briefly and 200 µl was manually pipetted into a separate collection tube containing the pooled sample. The collection tube (with a total volume of 5400 µl) was then briefly vortexed and 200 µl was used for paramagnetic bead-based RNA extraction using the Chemagic360 automated extraction system (PerkinElmer Inc., Cat.# CMG-1049, MA, USA). The purified nucleic acid was eluted in 100 µl of elution buffer. 10 µl of RNA was then used in the RT-PCR reaction (TaqPath™ COVID-19 CE-IVD RT-PCR Kit, Thermo Fisher Scientific). Group-level pools that were positive were sub-pooled into 9 slice-level pools, containing 9 samples each ( Supplementary Information-Table S1 ). Each sample found in the positive, group-level pool was represented in 3 different slice-level pools. As in the 3-d experiments, positive samples were chosen to represent the different quantiles of the Ct value distribution that is typical of our study population (Supplementary Information Fig. S1 ). One positive swab sample was combined with 80 negative swab samples in each of eight experiments (Experiments A-H). For each experiment, sample tubes were labelled from 1 to 81, and each of the respective positive samples was inserted blindly into a position within the 81-sample hypercube. Each sample was vortexed briefly and 200 µl was added to a separate collection tube containing the pooled sample. The collection tube (with a total volume of 16 200 µl for each experiment) was then briefly vortexed and 200 µl was used for RNA extraction and subsequent RT-PCR, as described above. For each experiment, the 81-sample pool was further sub-pooled into 12 slices containing 27 samples each (Supplementary Information- Table S2 ). Each individual sample was therefore represented in 4 different slices in each experiment. The programming codes for the 3-d and 4-d pooling experiments using the OT-2 liquid handling robot is available at https:// github. com/ krisp-kwazu lu-natal/ effic ient-SARS-CoV-2-pooled-testi ng-strat egy-code. Software for the de-bundling and inference of positive results. Custom scripts were implemented in Python for the de-bundling and inference of positive results from a pool of 27 or 81 samples. When inferring positive results, our scripts take into account degenerates and can infer more than one positive sample per pool at low prevalence. For ease of use, we developed a user-friendly, web-based front end using the Java Web Toolkit (Jwt), an open-source, robust Java web front end (GUI; http:// webto olkit. eu/ jwt) library. Minimal user interaction is required as user interaction is limited to uploading the files to be processed or providing pool details in the case of inference. A report detailing the de-bundling results is provided to the user once processing of the data is complete. Our de-bundling and inference software is freely available and can be accessed at the URL: http:// krisp2. ukzn. ac. za: 8080/ rega-pooli ng/ pooli ng. The programming scripts for the software we developed are available at https:// github. com/ krisp-kwazu lu-natal/ effic ient-SARS-CoV-2-pooled-testi ng-strat egy-code. Characteristics of SARS-CoV-2 and COVID-19 Molecular architecture of early dissemination and massive second wave of the SARS-CoV-2 virus in a major metropolitan area Emergence and rapid spread of a new severe acute respiratory syndrome-related coronavirus 2 (SARS-CoV-2) lineage with multiple spike mutations in South Africa Characteristics and outcomes of COVID-19 patients during initial peak and resurgence in the Houston metropolitan area A novel variant of interest of SARS-CoV-2 with multiple spike mutations detected through travel surveillance in Africa Review on Newly Identified Coronavirus and its Genomic Organization The emergence of a mutated SARS-COV-2 lineage in South Africa Lessons from applied large-scale pooling of 133,816 SARS-CoV-2 RT-PCR tests Asymptomatic SARS Coronavirus 2 infection: Invisible yet invincible The detection of defective members of large populations A pooled testing strategy for identifying SARS-CoV-2 at low prevalence Nano-enabled biosensing systems for intelligent healthcare: towards COVID-19 management Grand challenges in bio-nanotechnology to manage the COVID-19 pandemic Viral cultures for COVID-19 infectivity assessment. Systematic review Duration of infectiousness and correlation with RT-PCR cycle threshold values in cases of COVID-19 Epidemiologic features and clinical course of patients infected with SARS-CoV-2 in Singapore Predicting infectious Severe Acute Respiratory Syndrome Coronavirus 2 from diagnostic samples Virology, transmission, and pathogenesis of SARS-CoV-2 Diagnostics for SARS-CoV-2 infections Inflated false-negative rates in pooled RT-PCR tests of SARS-CoV-2. medRxiv A method for detecting all defective members in a population by group testing A sensitive and affordable multiplex RT-qPCR assay for SARS-CoV-2 detection Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection Ethics declarations. We used de-identified remnant nasopharyngeal and oropharyngeal swab samples from patients tested positive for SARS-CoV-2 by RT-qPCR from public health laboratories in South Africa. The authors declare no competing interests. Supplementary Information The online version contains supplementary material available at https:// doi. org/ 10. 1038/ s41598-021-96934-z.Correspondence and requests for materials should be addressed to L.S., W.N. or T.O.Reprints and permissions information is available at www.nature.com/reprints. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.