key: cord-0721383-k084ott7 authors: Ou, Q.; Placucci, R. G.; Danielson, J.; Anderson, G.; Olin, P.; Jardine, P.; Madden, J.; Yuan, Q.; Grafe, T. H.; Shao, S.; Hong, J.; Pui, D. Y. H. title: Characterization and mitigation of aerosols and splatters from ultrasonic scalers date: 2021-03-01 journal: nan DOI: 10.1101/2021.02.26.21252487 sha: 503c70fdb4fae4dfd9766cecbb84067d09846dde doc_id: 721383 cord_uid: k084ott7 Background: Dental procedures often produce aerosols and splatter which have the potential to transmit pathogens such as SARS-CoV-2. The existing literature is limited. Methods: Aerosols and splatter were generated from an ultrasonic scaling procedure on a dental mannequin and characterized by two optical imaging methods - digital inline holography (DIH) and laser sheet imaging (LSI). Capture efficiencies of various aerosol mitigation devices were evaluated and compared. Results: The ultrasonic scaling procedure generates a wide size range of aerosols up to a few hundred micrometers and occasional large splatter which emit at low velocity (mostly below 3 m/s). Use of a saliva ejector (SE) and high-volume evacuator (HVE) resulted in 63% and 88% of overall reduction respectively while an extraoral local extractor (ELE) resulted in a reduction of 96% at the nominal design flow setting. Conclusions: The study results showed that the use of ELE or HVE significantly reduced aerosol and splatter emission. The use of HVE generally requires an additional person to assist a hygienist, while an ELE can be operated hands-free when a dental hygienist is performing ultrasonic scaling and other operations. Practical Implications: An extraoral local extractor aids in the reduction of aerosols and splatters during ultrasonic scaling procedures, potentially reducing transmission of oral or respiratory pathogens, like SARS-CoV-2. Position and airflow of the device are important to effective aerosol mitigation. There is a general consensus that aerosols are one of the major paths of transmission for SARS-46 CoV-2 in the current pandemic 1 . This has led to concerns for health care workers involved in 47 procedures which generate aerosols 2-5 . Dental providers are thought to be at particular risk due 48 to the generation of aerosols and splatters 6-10 during dental procedures such as ultrasonic 49 cleaning and high-speed, water-cooled tooth preparation. The dental profession has responded 50 with increased use of personal protection equipment (PPE) and recommendations to avoid 51 aerosol generating procedures such as ultrasonic scaling. Current industry guidelines for 52 addressing airborne risks focus on increased ventilation (or air changes per hour (ACH)), portable 53 room filtration systems (not at the source), the avoidance of discretionary aerosol-generating 54 procedures (AGPs), and adding time between patients and procedures to allow for increased 55 ventilation 6,7,11 . These measures have understandably placed increased burden on the oral health Dental procedures generate both aerosols and splatter. Without a commonly recognized size 71 threshold, splatters are generally considered to be large droplets and/or debris that is heavy 72 enough to settle rapidly without spreading a long distance. Aerosols, on the other hand, are small 73 droplets that can become smaller through evaporation and result in smaller residual aerosols (10 74 microns in size or smaller) that may stay suspended in air indefinitely since they are sufficiently 75 small to overcome gravitational settling, especially in a thermally stratified indoor environment 32-76 34 . Although most of these residual aerosols are the result of the supplied cooling water, they can 77 include patient saliva, dental plaque, calculus, and blood, which can be infectious to dental 78 practitioners or other dental patients if a patient carries SARS-CoV-2 or other infectious agents. 79 Since a droplet's ability to spread and subsequently be inhaled strongly depends on its original 80 size and evaporation process, a comprehensive size characterization of the original droplets and 81 the residual aerosols is essential in risk assessment of AGPs. Such a comprehensive assessment 82 has not been reported yet to our best knowledge. 83 One example of a common dental hygiene procedure which is being avoided during the pandemic 84 due to aerosol generation is ultrasonic scaling for dental prophylaxis 4 . This ultrasonic scaling 85 technology increases the efficiency of dental hygienists and is much less physically demanding 86 than manual scaling. Dental hygienists are at risk for repetitive stress injuries and the ban on 87 ultrasonic scaling procedures makes this more likely. The reduced efficiency of manual scaling 88 also increases the time the patient is seating in the dental chair and for some patients may 89 increase the number of appointments needed. High-volume evacuation (HVE) is reported to 90 reduce aerosol contamination considerably 23,35,36 , but it is generally not used by dental hygienists 91 without an additional assistant to hold, position and manipulate the end of the HVE. Extraoral 92 local extractors (ELE) have been discussed and marketed since the beginning of this pandemic, 93 but the evidence supporting their effectiveness is rare 37,38 and details about the proper design, 94 configuration and use of ELEs has not been studied and reported. 95 We conducted this experiment to provide detailed physical characterizations of aerosols and 96 splatters from ultrasonic scaling processes using novel in-situ optical methods. The methods were 97 further used to evaluate the effectiveness of a variety of dental aerosol mitigation devices. 98 Digital Inline Holography (DIH) and Laser Sheet Imaging (LSI) were used to characterize the size 100 and velocity of aerosols and splatters from an ultrasonic scaling procedure. DIH can be leveraged 101 to image particles larger than 6 μm but is limited to a small sample volume. On the other hand, 102 LSI is not capable of distinguishing particle sizes, but can be used to count particles in a wide 103 field of view. The combination of DIH and LSI measurements was therefore employed for more 104 holistic insight into the generation and mitigation of aerosols during the dental procedure. This 105 also provided an effective methodology for the evaluation of various aerosol mitigation strategies 106 and devices. 107 Near-field in situ holographic measurements were conducted using a DIH setup consisting of a 109 laser, a digital camera, as well as beam expanding, collimating and condensing optics. A dental 110 mannequin with thermoplastic teeth was placed on a horizontal surface facing upwards to mimic 111 a patient during the dental procedure. The center of the DIH sample volume (15.6×13.0×250 mm 3 ) 112 was located approximately 8 mm above the mannequin's mouth opening (Figure 1) . 113 The hybrid hologram processing method proposed by Shao et al. 39 , consisting of image 114 enhancement, digital reconstruction, particle segmentation and post-processing was used to 115 obtain the size distribution of particles passing through the DIH sample volume during simulated 116 dental procedures. 117 A dental hygienist simulated supragingival scaling of the facial surfaces of the upper incisors and 119 the lingual surfaces of the lower incisors using an ultrasonic scaler (Dentsply Sirona Cavitron ® 120 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Plus with 30K FSI-1000 inserts) operating at the medium power setting while the holographic 121 sensor (35 fps, 13 μs exposure) acquired 10-second videos for a total of three trials. Clinically 122 ultrasonic scaling in these dental regions generates the most splatters and aerosols. 123 Various mitigation devices were subsequently tested including a saliva ejector (SE, operated by 125 the hygienist), a high-volume evacuation (HVE, operated by a second person) and an extraoral 126 Far-field in situ laser sheet imaging was conducted using the setup illustrated in Figure 2 , which 137 comprised of a high-resolution camera coupled with an image intensifier and an imaging lens, as 138 well as a light sheet generating system. The dental mannequin was placed in a horizontal surface 139 facing upwards in a fashion similar to the previous setup. The light sheet generating system was 140 placed 80 cm to the side of the center of the camera's field of view (FOV) and used to generate 141 a light sheet that crossed the mannequin's head just above its mouth opening and below its nose. 142 The camera module, located 60 cm away from the mannequin, was oriented perpendicularly to 143 the light sheet and focused to achieve a FOV of 40×40 cm 2 . Additional measures were taken to 144 ensure the signal to noise ratio was maximized, such as spray-painting the mannequin head and 145 implementing a light trap to diminish background reflection. 146 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Recorded images were converted grayscale and enhanced using background subtraction. The 147 plume of aerosol generated during the procedure was segmented by employing an entropy filter, 148 and the total pixel intensity of the plume area was measured and compared to the mitigation-free 149 test trial to obtain the device's capture efficiency. 150 The ultrasonic scaling simulation and the mitigation techniques were tested with LSI in the same 151 manner previously described with DIH. This provided a complementary broader field of view for 152 the generated droplets and aerosols, as well as their mitigation. More than 65% of the droplets had a velocity below 1 m/s and less than 2% of the droplets had a 170 velocity greater than 3 m/s (See Figure 4) . The low average droplet velocity observed here 171 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted March 1, 2021. ; https://doi.org/10.1101/2021.02.26.21252487 doi: medRxiv preprint size-dependent capture observed by DIH that droplets with large momentum (larger size and/or 198 higher speed) have relatively higher chance to escape from the capture of a mitigation device. 199 Without distinguishing individual particles and their sizes, an overall capture efficiency was 200 obtained from LSI data for each mitigation device (or their combinations) as shown in Figure 6 . 201 Among saliva ejector, HVE, and ELE at 14 cm working distance, saliva ejector had the lowest 202 capture efficiency at 63%, followed up the local extractor at low flow setting (74%). HVE showed 203 a higher capture efficiency at 88%. The ELE operating at high speed setting provided the best 204 capture with an efficiency of 96%. A combination of local extractor at high flow setting with either 205 saliva ejector (94%) or HVE (95%) did not provide additional improvement in capture efficiency, 206 which implies the best mitigation strategy may be to use a local extractor (with proper flow setting, 207 nozzle design, and placement relative to the patient and their oral cavity). 208 The reported efficiencies for LSI were consistently lower than those by DIH at size from 30 to 120 209 µm, which can be explained by two reasons: (1) the existence of large splatters (with lower capture 210 efficiency) in LSI video reduces the overall efficiency since a single large splatter contributes more 211 intensity signal than a small droplet; and (2) the differences in size and position of the field of view 212 between DIH and LSI result in characterizations of different portions of aerosol and splatter 213 populations from the same source. 214 When the local extractor was moved 4 cm further away (from 14 to 18 cm) from the generation 215 site, its capture efficiency dropped substantially from 74% to 38% at low flow setting, and from 216 96% to 56% at high flow setting. 217 Dental aerosols and splatters are an important potential transmission mode for many pathogens, 219 including SARS-CoV-2, and it is vital to understand their generation profile and transportation 220 behaviors in air to support the risk assessment and aerosol mitigation in the current COVID-19 221 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The droplet size and velocity reported here are properties measured close to their generation site 234 outside of the oral cavity. When they travel further in the air, the droplets evaporate to significantly 235 smaller size and the velocity relaxes close to the movement of the surrounding air. In view of the 236 respiratory disease transmission, particles smaller than 10 µm (the size after droplets have 237 reduced in size due to evaporation) pose more risk than larger ones since they are more likely to 238 remain suspended in air 40 , to bypass a face shield, to penetrate through face masks / 239 respirators 41-43 , and be inhaled and deposited in the respiratory tract. The residual particle size 240 depends on the size and composition of the original droplets. For dental generated droplets, 241 especially ultrasonic scaling, this is dominated by dissolved solid impurities in the cooling water 242 which is typically tap water filtered with a bacterial filter. Assuming a total dissolved solid (TDS) 243 level of 350 ppm for a typical tap water 44,45 , a droplet with a 142-µm original size dries into a 10 244 µm solid residual, suggesting droplets smaller than ~150 µm should receive more attention in 245 dental aerosol mitigation. Larger droplets, however, can deposit onto ground, dental chairs and 246 other equipment, bodies of patients or dental operators, surfaces of face shield, face mask, or 247 respirators, causing potential surface contamination. These findings therefore support the 248 continued use of enhanced PPE in addition to regular surface cleaning and disinfection. The 249 optical methods used in this study focus on initial droplets greater than 12 µm since any droplets 250 smaller can be effectively mitigated as suggested by the size-dependent capture efficiency shown 251 in Figure 5 . 252 The ultrasonic scaler did produce omnidirectional droplets as expected, due to the high-frequency The low average droplet velocity observed in this study suggests suction-based point-of-source 260 mitigation strategies such as those tested may be more effective than whole-room-ventilation-261 based mitigation as has been recommended in other settings 12,46 . The ELE works in a similar 262 principle as a saliva ejector or an HVE, but at a higher flowrate and a longer working distance. 263 Unlike an HVE, it can be designed to remain in a fixed position, so an extra assistant is not needed 264 to operate it. 265 It should be noted that room ventilation provided by heating, ventilation and air conditioning 266 systems (HVAC) alone would require significantly higher flow for aerosol mitigation due to lack of 267 focus on contamination sources. And it is possible that air ventilation provided by an HVAC system 268 could contribute to aerosol spread rather than mitigation, as an aerosol could travel throughout 269 an entire room before eventually being vented by the room HVAC system (where it may be 270 recirculated if not properly filtered.) With ELE, however, the majority of contaminants are captured 271 by the ELE at the source and subsequently filtered. 272 All rights reserved. No reuse allowed without permission. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Not every aerosol or splatter from ultrasonic scalers carries pathogens, so the emission profiles 274 measured in this study represent a worst-case scenario, which need to be combined with a 275 biological property evaluation for a more comprehensive risk assessment in the future. Since our 276 knowledge on the infective dose of SARS-CoV-2 required to cause COVID-19 is still limited, it is 277 difficult to draw definitive conclusions as to the risks posed by dental aerosols and splatters and 278 if the reported efficacy of the mitigation devices is sufficient. It is therefore recommended that 279 multiple mitigation strategies be employed to minimize the risk of dental aerosol transmission. 280 The authors also recommend that dental practitioners continue to use enhanced PPE in addition 281 to other aerosol mitigation techniques. 282 (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted March 1, 2021. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted March 1, 2021. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted March 1, 2021. (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted March 1, 2021. ; https://doi.org/10.1101/2021.02.26.21252487 doi: medRxiv preprint COVID-19 and its Modes of Transmission Aerosol-generating procedures and infective risk to healthcare 300 workers from SARS-CoV-2: the limits of the evidence Two Cases of Inadvertent Dental Aerosol Exposure to COVID-303 Possible aerosol transmission of COVID-19 and special 306 precautions in dentistry Aerosol-generating otolaryngology procedures and the need for enhanced PPE 308 during the COVID-19 pandemic: A literature review World Health Organization; 2020. 312 7. Centers for Disease Control and Prevention. Interim Infection Prevention and Control Guidance 313 dental procedures for 316 preventing infectious diseases ( Review ) Transmission routes of 2019-nCoV and controls in 319 dental practice Office of Chief Dental Officer England. Standard operating procedure. Transition to recovery Evaluating aerosol and splatter following dental 329 procedures: Addressing new challenges for oral health care and rehabilitation Evaluation of the 332 spatter-reduction effectiveness of two dry-field isolation techniques All rights reserved. No reuse allowed without permission the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted Quantitative 335 measurements of aerosols from air-polishing and ultrasonic devices: (How) can we protect 336 ourselves? Evaluating contaminated dental aerosol and splatter in an 338 open plan clinic environment: Implications for the COVID-19 pandemic Aerosol and Splatter Contamination from the Operative 341 Site during Ultrasonic Scaling The efficacy of an extraoral scavenging device on reduction 344 of splatter contamination during dental aerosol generating procedures: an exploratory study Clinical use of an aerosol-reduction device with an ultrasonic scaler. Compend Contin 347 Educ Dent Evaluation of Minimum Required 349 Safe Distance between Two Consecutive Dental Chairs for Optimal Asepsis Dental aerosols: microbial composition and spatial 352 distribution Comparison of suction device with saliva 354 ejector for aerosol and spatter reduction during ultrasonic scaling Evaluating spatter and aerosol contamination during 357 dental procedures Atmospheric 359 contamination during ultrasonic scaling A Novel Coronavirus from Patients with Pneumonia in China Measurement of airborne 364 bacteria and endotoxin generated during dental cleaning Jacks ME. A laboratory comparison of evacuation devices on aerosol reduction A clinical study measuring dental 375 aerosols with and without a high-volume extraction device Evaporation and dispersion of exhaled droplets in 378 stratified environment Direct or indirect exposure of exhaled contaminants 381 in stratified environments using an integral model of an expiratory jet The lock-up phenomenon of exhaled flow in a stable 384 thermally-stratified indoor environment. Build Environ Aerosols how dangerous they are in clinical 387 practice The usefulness of 391 the modified extra-oral vacuum aspirator (EOVA) from household vacuum cleaner in reducing 392 bacteria in dental aerosols Effectiveness evaluation of different suction systems Hinds WC. Aerosol technology: properties, behaviour, and measurement of airborne particles. 399 Published online 1982 Alternative Face Masks Made of Common Materials for 403 General Public: Fractional Filtration Efficiency and Breathability Perspective Evaluation of decontamination methods for 406 commercial and alternative respirator and mask materials -view from filtration aspect Attenuation of contaminants of emerging concerns by nanofiltration 412 membrane: rejection mechanism and application in water reuse Industrial ventilation design method. In: Industrial Ventilation 418 Design Guidebook All rights reserved. No reuse allowed without permission which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity