key: cord-0721381-fxttv1bl authors: Parhizkar, Hooman; Fretz, Mark; Laguerre, Aurélie; Stenson, Jason; Corsi, Richard L.; Van Den Wymelenberg, Kevin G.; Gall, Elliott T. title: A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields date: 2022-03-11 journal: Res Sq DOI: 10.21203/rs.3.rs-1437107/v2 sha: 39c117baae5a90f8e1c21c89ad8a64d175f49dc2 doc_id: 721381 cord_uid: fxttv1bl Several studies suggest that far-field transmission (> 6 ft) explains the significant number of COVID-19 superspreading outbreaks. Therefore, quantitative evaluation of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 2.5 ft, 5 ft, 7.5 ft from the participant, as well as in the exhaust plenum of the chamber. We observed that 2.5 ft trials had substantially (~36–44%) higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 2.5 ft, 5 ft, and 7.5 ft were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. Our findings highlight the importance of far-field transmission of airborne pathogens including SARS-CoV-2, which need to be considered in public health decision making. The spread of COVID-19 has caused extensive damage to the lives of millions of people worldwide. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19, is transmitted from human to human via bioaerosols particles that are released during respiratory activities such as breathing, talking, singing, and coughing. [1] [2] [3] Substantial evidence supports that indoor spaces are hotspots where COVID-19 transmits beyond 6 ft of the source emitter. [3] [4] [5] [6] [7] Furthermore, epidemiological studies, public health, and engineering risk assessment models indicate that the majority of well-documented superspreading outbreaks can be explained by bioaerosols beyond 6 ft from the source emitter. [8] [9] [10] Therefore, quantifying the degree of exposure to bioaerosols according to distance from the emitting source is critical to more accurately characterize disease transmission risk, to determine the most effective risk reduction strategies such as ventilation, ltration, and spatial distancing, and ultimately to reduce disease transmission. A well-mixed air space is a conventional assumption that has been used in most studies of indoor air pollution and infectious disease transmission modeling. 11 For a well-mixed condition, indoor air contaminants, including virus laden aerosol particles, are assumed to be uniformly distributed by appropriate ventilation, interior mixing fans, buoyancy driven ows, and in ltration, immediately after being emitted from the source. 12 However, thermal strati cation, inadequate ventilation, and some environmental conditions can cause a non-uniform distribution of bio-aerosols in indoor spaces, 13, 14 where the probability of susceptible occupants inhaling virus-laden aerosol particles will rely, at least to some extent, on the distance from the source emitter. Few studies have considered the importance of spatial parameters such as room height into measurements of indoor pollutants. [15] [16] [17] [18] A study of temporal and spatial scales suggests that chemical compounds as well as particles in the range of 1-10 µm with persistent residence time exhibit spatial gradients that are signi cantly controlled by ventilation rates. 19 Additionally, controlled experiments on participants who were diagnosed with COVID-19 were used to study the abundance of SARS-CoV-2 viral RNA copies in room aerosols. The authors found that the near-eld was associated with a higher number of virus RNA copies, and statistically higher carbon dioxide (CO 2 ), and particle counts of 0.3 µm -2.5 µm than in the far-eld. 3 Differences between near-eld and far-eld were also examined through CO 2 and particles with patients receiving high-ow nasal cannula therapy (HFNC), where the CO 2 concentration was statistically higher at a distance 0.5 m (~1.6 ft) from the source emitter compared to background levels. 20 The goal of the present study is to better characterize the impact of distance from source on distribution of exhaled bioaerosols in an indoor environment. A novel trace gas approach is proposed where a participant consumed breath mints and released known compounds in exhaled breath. A previous study has shown that chewing peppermint avored gum is associated with release of unique volatile organic compounds (VOCs) such as menthone and menthol, with source strength dependent on oral activity and chewing frequency. 21 Real-time measurements of VOCs can provide useful information for studying pollutant dynamics of indoor environments. 22 We used proton transfer reaction -time of ight -mass spectrometry (PTR-ToF-MS) to measure volatile organic compounds (VOCs) associated with breath mints across a mass range of 17-490 amu with 1 second time resolution. The principles of the PTR-ToF-MS measurements have been well-described previously. [23] [24] [25] This approach allows for a realtime measurement of VOCs with a proton a nity greater than that of H 2 O. In theory, ionization is soft, allowing for little fragmentation, and compound identi cation can be made by observation of the [M+H]+ ion (i.e., molecular mass + the mass of the transferred proton). Our study used breath mints instead of chewing gum to trace three speci c compounds (menthone, monoterpenes, and menthol). Human subjects protocols were reviewed and approved by the University of Oregon Institutional Review Board (IRB) (Protocol #20210509). One human subject participated in this study. The participant was instructed to: 1. not use cologne or body sprays during the day preceding and during the study period; 2. wear clothes that were not recently washed with detergents; 3. follow a consistent diet during the course of three data collection days; 4. maintain a constant breath mint consuming rate during all trials. Experiments were conducted at the Energy Studies in Buildings Laboratory, Portland, OR, USA, using a custom environmentally-controlled climate chamber with an interior volume of 27 m 3 ( Figure 1A ). Filtered air was supplied through a ceiling plenum and exhausted through a oor plenum. Air was exchanged at 3 air changes per hour (ACH) during test periods and ushed at > 20 ACH for a minimum of 20 minutes between trial periods. We observed the concentration of breath tracers during the experiment as a distinct VOC that is associated with breath mints to con rm the removal of previous residuals before the beginning of each trial. Ambient indoor air was supplied through a MERV-13 pre lter and high-ow activated carbon lters (Air Box 4 Stealth; AirBox Filters, Laval, Quebec, CA) and exhausted through an identical ltration system (shown as supply lter package and return lter package in Figure 1A ). Air exchange rates were monitored throughout the experiments by balancing supply and exhaust air velocities measured at centerof-duct locations using a thermal anemometer and multi-function ventilation meter (#964 and #9565-P, respectively; TSI Incorporated, Shoreview, MN, USA). Each trial began with adjustment of the climate chamber's ventilation rate to the maximum value (20 ACH) for a minimum duration of 20 minutes without the presence of the participant in order to evacuate detectable residuals of prior trials ( Figure 1B ). We monitored the concentration of menthone to assure it reached a negligible steady-state background concentration. Next, the participant was instructed to enter the chamber, sit in a chair, and breathe normally for ve minutes without consuming any breath mints. These 5-minute periods provided a baseline reference for each trial and were included in the study protocol to identify certain compounds that are exclusively associated with natural human breath and not breath mint avoring, and to additionally provide a baseline to observe any exhaled compounds that may have remained in the participant's mouth from previous trials. After 5 minutes, the participant was visually informed to begin consuming one breath mint every 10 minutes ( Figure 1B ), resulting in 6 breath mints consumed during each 1-hour trial (minutes 0, 10, 20, 30, 40, and 50). All breath mints were carried into the chamber by the participant in an air sealed plastic bag. To keep emissions relatively constant, the participant was instructed to remain silent and minimize body movement during the entire course of study. The participant also took care to maintain a resting activity level between trials to avoid emission irregularities while inside the chamber during the trials. A summary of all trials conducted in this study is presented in Table 1 . We used a single sampling line attached to a portable tripod and moved the probe to designated spots on the oor, measuring 2.5 ft, 5 ft and 7.5 ft from the participant's mouth (Table 1 , Trials A-C). Additionally, we placed another sampling line of equal length inside the oor plenum exhaust duct (called exhaust trials) to measure exhaust air as a "well-mixed" approximation of the volume -averaged concentration (Table 1 , Trial D). In addition to trials A-D (Table 1) within the climate chamber ( Figure 1A) , we conducted two other experiments to con rm the presence of unique tracer compounds associated with the exhaled breath of the participant consuming breath mints (Trials E&F, Table 1 ). In trial E, we placed one single breath mint in the headspace of a 250 mL glass container for ~1 minute and monitored the concentration of VOCs over a 20-minutes period. In trial F, the participant was instructed to consume one breath mint while breathing normally into the same 250 mL glass container for ~1 minute. Similar to trial E ( Analyses were performed using the statistical programming environment R. The Taylor expansion 26 procedure was applied using the propagate package 27 to calculate the expanded uncertainties associated with VOC measurements (Supplemental gure 2 Supplemental table1). The ratio of samples collected at 2.5, 5, and 7.5 ft were normalized by the volume-averaged concentration resulting in a series of magni ers for each distance expressed in percentage values. The effect size associated with each magni er was assessed using the Cohen's D test. 28, 29 Results Menthone, menthol, monoterpenes, isoprene, and acetone were selected for further analysis. We conducted paired t-test analyses between the rst and last minute of baseline periods during which the participant did not consume breath mints in the chamber (n = 60). Table 2 presents the results of paired ttests between the rst and last minute of the baseline periods for each distance. The concentration of menthone, menthol, and monoterpenes did not change (p > 0.05) during baseline periods when the participant did not consume breath mints, while the concentration of isoprene and acetone changed during the baseline periods. This indicates that acetone and isoprene were detected in the participant's natural breath. Upon further review, the changes were inconsistent with breath sources only, suggesting other indoor sources such as the participant's skin and climate chamber interior materials may have contributed to the variability. Therefore, we summed the concentrations of menthone, menthol, and monoterpenes as unique breath tracer for the comparison of different distances in this study. In addition to the analysis of baseline periods presented in Table 2 , the presence of menthone, menthol, and monoterpenes in the exhaled breath of the participant while consuming breath mints was additionally con rmed through trials E & F (Table 1 ). Figure 2 indicates that the concentrations of menthone, menthol, and monoterpenes substantially increase when the breath mint was placed in the headspace of a 250 ml container (Figure 2A) , or when the participant breathed naturally into the 250 ml container ( Figure 2B ). Furthermore, Supplemental gure 1 shows the concentration of major VOCs during ventilation and baseline periods, indicating low but not necessarily zero concentrations for trials A-D (Table 1) . We hypothesize that baseline concentrations are associated with residual VOCs that were adsorbed by climate chamber or ventilation lter surfaces and slowly re-emitted into the chamber air. To make a consistent starting point for all trials, we subtracted the average concentration of each compound detected during baseline periods from the 60-minute sampling period measurements. The concentration of each compound for duplicate trials at each sampling location was averaged to produce a single data set for each of the distance trials (2.5 ft, 5 ft, 7.5 ft, and exhaust trials). Thereafter, the modi ed concentrations of menthone, monoterpenes, and menthol were summed to create a single value as breath tracer for each distance. A comparison of summed breath mint VOC concentrations normalized by the volume-averaged concentration is shown for each distance in Figure 3 . Supplemental table 1 reports on the magni ers, expanded uncertainties associated with each value, as well as Cohen's D effect size statistics for each distance. Supplemental gure 2 demonstrates the uncertainties associated with the values presented in Figure 3 . We used PTR-ToF-MS to trace the concentration of select VOCs associated with a consumed breath mint as a proxy for bioaerosol emissions from a healthy participant during each 60-minute trial. We summed the concentrations of menthone, monoterpenes, and menthol in each trial as a unique breath tracer since they were only detected only when the participant consumed breath mints. The summed tracer concentrations detected at 2.5, 5 ft, and 7.5 ft from the participant were normalized by volume-averaged concentration (VAC), which indicates the magni er of each location compared with an approximate wellmixed condition. As shown in Figure 1 , the concentration of VOCs at 2.5 and 5 ft rise above volumeaveraged concentration during the rst 5 minutes of the study, while the concentration at 7.5 ft begins to rise below the VAC level after minute 10 ( Figure 2 ). We observed a steep increase in the concentration of breath tracers at 2.5, 5, and 7.5 ft during the rst 5 minutes, which show that signals were rst detected at closer range distances compared to the exhaust plenum due to a concentrated exhaled plume that had not mixed extensively throughout the chamber. At minute 5, the concentration of breath tracers also began to rise in the exhaust plenum, resulting in decreases in the ratios of indoor sampling locations normalized by the VAC (Figure 2 ). It took approximately 10 minutes for the concentration of breath tracers to become mixed in the chamber. At minute 10, the concentration of human tracers begins to increase in 2.5 ft trials against VAC, resulting in a higher concentration at 2.5 ft during minutes 5-20 compared to all other locations, with a 36-44% higher concentration than VAC. This nding suggests that the risk of exposure to virus-laden aerosol particles during the rst 20 minutes is relatively higher for close contact distances (less than 3ft) when compared with other distances. Meanwhile, the concentration of breath mint tracers at 5 and 7.5 ft also rise above VAC during minutes 20-25, with the greatest magni er having a value of 17% higher than VAC at 5 ft. After 25 minutes, tracer concentrations at 2.5, 5, and 7.5 ft maintained a relatively consistent trend in the ratio of distance-speci c concentration normalized by VAC was observed. The magni ers during this approximate steady-state period were ~18% (, ~11%(, and 7.5%( above VAC at 2.5, 5, and 7.5 ft, respectively. The expanded uncertainties associated with values reported in Supplemental table 1 are in agreement with previous studies that measured VOCs using PTR-ToF-MS. 30 Despite the fact that Cohen's d statistics show large effect size values when the concentration of breath tracers at 2.5, 5, and 7.5 ft were compared to VAC 31 , the uncertainty associated with our measurements suggest that reported magni ers presented in Supplemental table 1 should be studied further with more replicates to improve the accuracy of and con dence in the near-eld to far-eld multipliers. Meanwhile, these ndings highlight the importance of both near-eld and far-eld exposure events, and emphasize the importance of exposure duration in consideration of near-eld and far-eld prioritization. In this study, given these room characteristics and air ow rates the 20-25-minute event threshold helps to differentiate the dominance of near-eld exposure risks, whereas longer events suggest dominance of far-eld exposure minutes) risks. Appendix A of the Supplemental document describes two case studies that present results of near-and far-eld magni ers for a recent controlled study on individuals that were diagnosed with COVID-19 (Supplemental table 2 ), 3 as well as a study of patients undergoing high-ow nasal cannula therapy. 20 Speci cally, as shown in Supplemental tables 3, the concentration of CO 2 and the particles of 1 µm -2.5 µm in the controlled study on participants who were diagnosed with COVID-19 3 were ~8 % and ~12 % higher in the near eld (4 ft from the participants), compared to the far eld (11 ft from the participants), respectively 3 . The present study provides con rmatory results in that the concentration of targeted VOCs in the near-eld (2.5 ft) was ~10% higher than the far-eld (7.5ft) during steady-state periods, thusproviding greater con dence for the concept of breath tracers as a proxy for virus laden bioaerosols. Our study provides a series of magni ers that could be used to estimate the concentration of bioaerosols at 2.5, 5, and 7.5ft from a human emitter in a reasonably well-mixed indoor space with ~ 3ACH over a 60minute exposure event duration. These multipliers can be used in future studies of microbial risk assessment models to superimpose near-led exposures and inhalation dose on far-eld exposures estimated using a well-mixed assumption. Here we demonstrated that the concentration of detectable respiratory VOCs at 2.5, 5, and 7.5 ft were approximately ~18% , ~11%, and 7.5% higher, respectively, than volume-averaged concentration during steady-state periods. These magni ers are reasonably consistent with values reported for a controlled study on participants diagnosed with COVID-19 3 in which near-eld (4 ft) was associated with 8% -17% higher concentrations for CO 2 and particles (0.3 µm -3 µm), resulting in 1 cycle threshold (C T ), or two times, difference between the viral load detected in the near-eld and fareld (Supplemental document, Appendix A).Our ndings indicate that the concentration of bioaerosols in the far-eld is relatively close to the well-mixed assumption at a steady-state period, while close range distances are associated with relatively higher exposure levels during the rst 20 minutes of an emission exposure event. Our study was a pilot project with several limitations. Our data were limited to replicated trials and a constant ventilation rate of ~3 ACH. There are several other environmental variables that can be studied through the same methodology such as the impact of relative humidity, temperature, mixing fan, facial masking, and room volume. Ventilation strategies other than overhead (used in this experiment) should be considered with different ACHs in future efforts. We seek to study several other distances & positions from the source emitter (vertical and horizonal distribution) to improve the accuracy of magni ers with the intention of developing a comprehensive heterogeneous air space model for indoor air quality research. Comparison of 2.5, 5, and 7.5ft trials normalized by volume-averaged concentration. This is a list of supplementary les associated with this preprint. Click to download. NIEHsSupplementaldocumentV8.docx Viral load of SARS-CoV-2 in respiratory aerosols emitted by COVID-19 patients while breathing, talking, and singing Infectious SARS-CoV-2 in exhaled aerosols and e cacy of masks during early mild infection Quantifying environmental mitigation of aerosol viral load in a controlled chamber with participants diagnosed with COVID-19 Longitudinal analysis of built environment and aerosol contamination associated with isolated COVID-19 positive individuals Airborne transmission of respiratory viruses Viable SARS-CoV-2 in the air of a hospital room with COVID-19 patients Isolation of SARS-CoV-2 from the air in a car driven by a COVID patient with mild illness A quantitative risk estimation platform for indoor aerosol transmission of COVID-19. Risk Anal Poor ventilation worsens short-range airborne transmission of respiratory infection. Indoor Air It is time to address airborne transmission of Coronavirus disease 2019 (COVID-19) Modeling of Indoor Air Quality and Exposure US) Committee on Indoor Pollutants. Monitoring and Modeling of Indoor Air Pollution The spatial distribution of carbon dioxide in an environmental test chamber Effects of ventilation on the indoor spread of COVID-19 Quantifying source contributions for indoor CO2 and gas pollutants based on the highly resolved sensor data Indoor PM2.5 pro ling with a novel side-scatter indoor lidar Evaluation of particle resuspension in young children's breathing zone using stationary and robotic (PIPER) aerosol samplers The in uence of human activity on the vertical distribution of airborne particle concentration in con ned environments: Preliminary results Spatial and temporal scales of variability for indoor air constituents Near-eld airborne particle concentrations in young children undergoing high-ow nasal cannula therapy: a pilot study Release of peppermint avour compounds from chewing gum: effect of oral functions Observations and contributions of real-time indoor ammonia concentrations during HOMEChem On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research Validation of proton transfer reaction-mass spectrometry (PTR-MS) measurements of gas-phase organic compounds in the atmosphere during the New England Air Quality Study (NEAQS) in 2002 Long-term study of VOCs measured with PTR-MS at a rural site in New Hampshire with urban in uences Guideline 2-2005 ¿ Engineering Analysis of experimental data Package "propagate Statistical Power Analysis for the Behavioral Sciences CohensD function -RDocumentation Comparison of VOC measurements made by PTR-MS, adsorbent tubes-GC-FID-MS and DNPH derivatization-HPLC during the Sydney