key: cord-0721004-ygvhexup authors: Osman, Tarig; Lew, Eileen; Lum, Elaine Pooi-Ming; van Galen, Louise; Dabas, Rajive; Sng, Ban Leong; Car, Josip title: PreAnaesThesia computerized health (PATCH) assessment: development and validation date: 2020-11-14 journal: BMC Anesthesiol DOI: 10.1186/s12871-020-01202-8 sha: 7ee7c36a78d6405dc112f26ed6db04113f98e93a doc_id: 721004 cord_uid: ygvhexup BACKGROUND: Technological advances in healthcare have enabled patients to participate in digital self-assessment, with reported benefits of enhanced healthcare efficiency and self-efficacy. This report describes the design and validation of a patient-administered preanaesthesia health assessment digital application for gathering medical history relevant to preanaesthesia assessment. Effective preoperative evaluation allows for timely optimization of medical conditions and reduces case cancellations on day of surgery. METHODS: Using an iterative mixed-methods approach of literature review, surveys and panel consensus, the study sought to develop and validate a digitized preanaesthesia health assessment questionnaire in terms of face and criterion validity. A total of 228 patients were enrolled at the preoperative evaluation clinic of a tertiary women’s hospital. Inclusion criteria include: age ≥ 21 years, scheduled for same-day-admission surgery, literacy in English and willingness to use a digital device. Patient perception of the digitized application was also evaluated using the QQ10 questionnaire. Reliability of health assessment questionnaire was evaluated by comparing the percentage agreement of patient responses with nurse assessment. RESULTS: Moderate to good criterion validity was obtained in 81.1 and 83.8% of questions for the paper and digital questionnaires respectively. Of total 3626 response-pairs obtained, there were 3405 (93.4%) concordant and 221 (6.1%) discrepant response-pairs for the digital questionnaire. Discrepant response-pairs, such as ““no/yes” and “unsure/yes”, constitute only 3.7% of total response-pairs. Patient acceptability of the digitized assessment was high, with QQ10 value and burden scores of 76 and 30%, respectively. CONCLUSIONS: Self-administration of digitized preanaesthesia health assessment is acceptable to patients and reliable in eliciting medical history. Further iteration should focus on improving reliability of the digital tool, adapting it for use in other languages and incorporating clinical decision tools. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12871-020-01202-8. Current practice guidelines mandate that patients undergo preanaesthesia assessment prior to surgery and anaesthesia, defined as the process of clinical assessment that precedes the delivery of anaesthesia care for surgery and non-surgical procedures [1] . Its goal is to allow for timely identification and optimization of medical conditions, thereby reducing perioperative morbidity and mortality. Effective preoperative evaluation can also decrease case delays and cancellations on day of surgery [2] . Traditionally, preanaesthesia assessment is conducted by a health care provider via a face-to-face interview with the patient. Studies suggest that self-administration of digital assessment questionnaires is a feasible means of gathering medical information for preanaesthesia assessment [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] . Compared with in-person interviews, these digital selfassessment tools are associated with patient acceptance and satisfaction, reliability of information and improved efficiency of assessment [4, 6, 9] . At the preoperative evaluation clinic of our hospital, a 33-item preanaesthesia health assessment paper questionnaire is currently administered to elective surgical patients by nurses to gather medical information pertinent to preanaesthesia assessment [13] . Based on pre-determined criteria, responses help to identify patients with medical issues who require outpatient anaesthetic review 2 to 4 weeks in advance of surgery. Relatively healthy patients are allowed to bypass outpatient referral and undergo standard anaesthetic review on the day of surgery. The questionnaire has served our purpose well, but is not designed for patient self-administration as it contained technical language and medical terms. In line with global advances in information technology, healthcare institutions are increasingly leveraging on digital health technologies for care delivery. Local hospital statistics indicate that an average 900 patients are scheduled for elective surgeries every month and this number is expected to increase, as disease burden increases with an aging population. To cope with this demand, we postulate that a patient self-administered digital health assessment tool can be developed and implemented for the purpose of gathering medical history relevant for preanaesthesia assessment. The virtual tool allows remote access, so that assessment questionnaires can be completed at a time, place and pace convenient to the patient. The present study describes our experience in the development and validation of a patientadministered digital preanaesthesia health assessment questionnaire on a tablet device at a tertiary hospital. The study was conducted at a preoperative evaluation clinic that provides care for women scheduled for elective surgery at a tertiary hospital. A working group comprising three consultant anaesthetists, six clinic nurses and five digital health researchers from a local medical school sought to develop a patient self-administered digital preanaesthesia health assessment application through an iterative process. Ethics approval was granted by the Nanyang Technological University Institutional Review Board A mixed-methods approach was adopted. A paper version of the questionnaire was first designed and validated, before conversion to a digital prototype. We hereby refer to the paper versions as Forms 1 and 2 and the digital version as Form 3. All versions of the questionnaire were developed in English and iteratively, each version was an improvement over the previous. Figure 1 describes the phases of development and validation of the questionnaires from paper to digital formats. Phase 1: development and assessment of form 1 The self-administered paper questionnaire, Form 1, was designed after an extensive review of relevant literature via Pubmed and Google Scholar. Search terms used include (preanaesthesia or preanesthesia or pre-anaesthetic or preanesthetic or preoperative or pre-operative) and (health assessment or screening or questionnaire) and/or (validation). Shortlisted questionnaires were further examined for scope and relevance of domains and items, options of response types (i.e. binary/non-binary/free-text response), and design format of questions. Through consensus, the working group also determined the clinically relevant domains and corresponding items to be included in Form 1. First draft of Form 1 was then presented to twelve attending anaesthetists of the hospital for evaluation of its face validity. While the domains were deemed adequate, the anaesthetists suggested the addition of follow-up questions to qualify some items e.g. number of pack-years as a follow-up to a positive history of cigarette smoking. The draft of Form 1 was also evaluated at a workshop, where multidisciplinary staff of a local medical school provided feedback on its readability, clarity and contextualization. Participants suggested terms to replace technical jargon and reduced ambiguity in questions. Questions were structured according to domains of the body systems and each question was verified to assess only one domain or concept to the extent permissible (Supplementary Box 1). A glossary of terms (Supplementary Box 2) was also appended to provide explanation of medical terms. With the collective feedback obtained, Form 1 was finalised and administered as a pen-and-paper survey to a convenience sample of 33 patients in a pilot study, herewith referred to as "Study 1". The aim of this survey was to identify problems that were not addressed or considered during the design of the questionnaire. Inclusion criteria for patient recruitment were: age ≥ 21 years, ability to read and write in English and scheduled for same-dayadmission surgery. After written informed consent, all patients were given instructions on the completion of Form 1, with emphasis on unassisted self-assessment. Following that, each patient underwent a semi-structured interview using questions adapted from the QQ-10 questionnaire, [14] an established instrument for measuring face validity, feasibility and utility of healthcare questionnaires. For our purpose, the original QQ-10 questionnaire was modified by amending options of "mostly disagree" to "disagree" and "mostly agree" to "agree". Upon completion of the interview, each patient underwent a nurse-led assessment as per standard of care. Demographic data and time taken to complete Form 1 were recorded. Data from Form 1 was analyzed using IBM SPSS version 25 (IBM corp. Armonk, NY, USA). Data from the QQ-10 questionnaire was analyzed both quantitatively and qualitatively, using thematic analysis. Phase 2iteration of form 1 to form 2, with validation Form 2 was an iteration of Form 1, based on the feedback received from participants of Study 1. Improvements included the re-phrasing of questions to improve clarity and insertion of visual illustrations. The explanation of eight terms in the glossary section was also edited to improve ease of understanding (Supplementary Box 3). A validation study targeting a larger convenience sample size of 104 patients was conducted. Referred as "Study 2", 104 patients scheduled for same-day-admission surgery were recruited on presentation to the preoperative evaluation clinic during the designated study period. The primary aim of the study was to evaluate the criterion validity of Form 2 before its conversion to a digital prototype. The inclusion criteria were similar to those of Study 1. The sample size was chosen, based on a similar study reported in the literature [15] . Consenting patients first completed Form 2 independently, after which their responses were verified by the nurse via a structured face-to-face interview, guided by Form 2. If a discrepancy of response was noted, the nurse would make annotations upon verification with the patient. Each patient was also interviewed using the modified QQ-10 questionnaire, as described for Study 1. Criterion validity of the questionnaire was assessed by measuring the agreement between the patient responses and those obtained during nurse assessment. To account for questions with prevalence < 5% or > 95%, we have opted to report percentage agreement (PA), instead of the Kappa coefficient. PA is defined as number of questions with concurring responses divided by the total number of questions. Criterion validity is considered good if PA ≥ 95%, moderate if PA between 90 to < 95% and poor when PA < 90% [10] . The frequency of identical ("Yes/Yes", "No/No" and "Unsure/Unsure"), contradictory ("Yes/No" Fig. 1 Mixed-methods approach to the development of PATCH or "No/Yes"), and non-contradictory ("Unsure/Yes", "Unsure/No," "Yes/Unsure", and "No/Unsure") response pairs were also analysed. Sum of the contradictory and noncontradictory response rates describe the total discrepancy error rate. Data were analyzed using IBM SPSS version 25, as described for Survey 1. The iteration of Form 2 to Form 3 (the first digital protoype) was based on findings obtained from Phase 2 and renewed input from the working group (Supplementary Box 4). The digital application, called PreAnaesThesia Computerized Health assessment, or PATCH, was developed on an iOS platform on a tablet, using React Native (JavaScript framework). The server was made using NodeJS, a JavaScript framework. Data was stored on MongoDB database. For the purpose of the study, the server program and database were located on a secure server at the Nanyang Technological University. Improvements adopted for Form 3 included further rephrasing of questions to reduce ambiguity and deletion of questions deemed to be irrelevant. To facilitate patients in listing their medications and previous surgeries, a drop-down list of common medications and surgeries was developed, using data gathered from participants in Phase 1 and 2. The glossary of terms was configured to appear as pop-up boxes of explanation when activated by screen-touch. In addition, the application was designed to provide a summary page for review and final edit before submission. Screenshots of the digital prototype are shown in Supplementary Figure 1 . As the criterion validity of a paper questionnaire does not necessarily extend to its electronic format [16] , validation of the digital prototype, Form 3, was conducted in Study 3. In addition to the inclusion criteria described in the earlier phases, the ability to use a tablet device was added as a criterion for recruitment. One hundred and six patients were recruited at the preoperative evaluation clinic over 8 weeks. Consenting participants completed digital self-assessment on a tablet unaided, then underwent nurse assessment using a provider interface of the digital tool and with the nurse blinded to the patient's responses. PA for each response pair was measured. Time to completion of selfassessment was automatically captured by the application. Data was analysed using IBM SPSS verison 25. Of 33 patients recruited, 32 completed the study. One patient was excluded when the nature of admission was converted from same-day-admission to inpatient. Patients identified themselves as Chinese (23/71.9%), Malay (4/ 12.5%), Indian (1/3.1%), and others (4/12.5%), consistent with the ethnic distribution in the local general population. Median (IQR) age was 37 (32.2, 43) years. Median (IQR) time to complete self-assessment was 4 (3, 5) minutes. None of the patients identified any question as being uncomfortable to answer (Table 1) . Table 2 describes the patient perception of selected statements from the QQ-10. Overall, patient perception of self-assessment was favourable. A total of 48 feedback comments were obtained from 21 patients. They pertained mostly to the clarification of medical terms (13/61.9%) and availability of options to guide entry of medications and past surgeries (8 / 38.1%). These comments were taken into consideration in the iteration of Form 1 to Form 2. Of 104 patients recruited, 98 patients (94.2%) completed the study and 6 were excluded due to incomplete paperwork. The patients identified themselves as Chinese (50/ 51%), Malay (24/24.5%), Indian (10/10.2%), and others (14/ 14.3%), with a median (IQR) age of 38.5 (33, 44) years. Patients took 7.3 (5. 6, 9.4) [median (IQR)] minutes to complete pre-anaesthesia self-assessment and generally responded favourably to statements measuring value in the QQ-10 questionnaire (Table 3) . Among negative perceptions, length of questions emerged as the most frequent reason. Of note, 82 (83.7%) of participants were willing to utilize a digital version of the questionnaire in the future. Analysis of patient feedback on the design of Form 2 revealed a total of 56 comments from 32 (32.7%) patients. Majority of comments referred to the need for clarification of medical terms (23/71.9%). There were requests to shorten the length of the questionnaire (3/9.4%). Overall QQ-10 value and burden scores were 76% (SD = 13%) and 30% (SD = 12.5%), respectively. Mean score for value questions ranged from 2.9 to 3.3, while the mean score for burden questions ranged from 0.9 to 1.64. Table 4 shows the inter-rater reliability of Form 2. Good criterion validity was attained for 24 of 37 (65%) questions. Six (16%) questions were classified as having moderate criterion validity while seven (19%) had poor criterion validity. Total number of response pairs was 3626. Of these, 3432 were identical, giving a concordance rate of 94.6%. Sixtyseven (1.8%) were discrepant contradictory responses while 127 (3.5%) were discrepant non-contradictory responses, giving total discrepant responses of 194 (5.4%). Of these, the most common discrepant response pair was "unsure/ no" (94/2.6%), followed by "yes/no" (63/1.7%) and "unsure/ yes" (32/0.9%). Of 104 patients recruited, 98 (94.2%) patients completed the study. They were predominantly of Chinese (55/ 55.1%), Malay (18/18.4%) and Indian (6/6.1%) ethnicity. Notably, 88 (89.8%) patients were below 50 years old. Median (IQR) completion time to self-assessment on the digital application was 6.4 (4.8, 8.6) minutes. Table 5 shows the results of reliability testing of Form 3. Good criterion validity was obtained for 23 of 37 (62%) questions. Eight (22%) questions had moderate criterion validity while 6 (16%) questions had poor criterion validity. Total number of response pairs was 3626. Of these, 3405 were identical, giving a concordance rate of 93.9%. There were 133 (3.7%) discrepant contradictory responses and 88 (2.4%) discrepant non-contradictory responses, giving a total of 221 (6.1%) discrepant responses. The most common discrepant response pair was "yes/no" (89/2.5%), followed by "unsure/no "(76/ 2.1%), "no/yes" (44/1.2%), "unsure/yes" (11/0.3%) and "yes/unsure" (1/0.03%). Based on these findings, the working group made further enhancements to the digital application (Supplementary Box 6). In summary, the "unsure" option was deleted to encourage commitment to a definitive response. Probing stems of questions were also added to specific domains to improve qualification of symptoms. Drop-down options of past surgeries, medications and allergies were updated to include more choices. These amendments led to the development of an improved digital version. The feasibility of its implementation was reported in a study published recently [17] . Using a robust, mixed-methods approach, the present study describes the development and validation of a patient-administered digital assessment application on a tablet device for the purpose of gathering medical history relevant to preanaesthesia assessment. The PreAnaesthesia Computerized health Assessment (PATCH) application is accepted by patients and reliable when compared with nurse-led assessment. For health assessment instruments to have practical value, they should have reliability and validity. An example of content validity is face validitythe extent to which items are perceived to be relevant to the intended construct, while criterion validity is a dimension of reliability. Compared to published studies [10] , the present study achieved > 90% criterion validity in 84% of questions in the digital prototype. The difference could be related to differences in subject characteristics, such as literacy and social factors, which result in different perception and interpretation of the questions [15] . In the analysis of responses between patient selfassessment and nurse assessment, discrepant contradictory response-pairs, such as ""no/yes" and "unsure/yes", can be concerning as they suggest failure of the digital tool to detect an issue that is eventually uncovered by nurse assessment. Fortunately, these constitute only Was there any area that had too many questions on? 2 (6) 30 (94) Were there any questions you did not feel comfortable/expect answering? 0 (0) 32 (00) 3.7% of total responses in the validation of the digital prototype. The fact that 93.9% of total response-pairs were concordant strongly supports its reliability in gathering preoperative medical information. We observed that participants in the present study were mainly English-literate female, with median age < 40 years. Studies suggest that age and literacy can affect a patient's perception and willingness to adopt mobile health technology. In a systematic review to evaluate barriers in adopting telemedicine, age, level of education and computer literacy emerged as key patient-related determinants [18] . The authors speculated that preference for personalised care and lack of training in new technology among older patients could have contributed to this observation. In another study that examined the usage patterns of virtual health services, younger and predominantly female patients were more likely to be early adopters of virtual medical consultations [19] . In driving digital strategies for patient care, healthcare organisations must address the needs of patients and tailor the engagement platform according to patients' prefences and technology know-how. In the present study, 83.7% of participants in Phase 2 of the study had expressed receptiveness to the use of a digital self-assessment tool. This is not surprising, given the young age of our patients and the high internet penetration rate in the local population [20] . Concerns of data breach should be addressed with strict regulation and compliance with Health Level 7 (HL7) standards, through secure networks, data encryption, login controls and auditing. Positive patient acceptance of digital health assessment has motivated us to re-design our clinical pathways, leveraging on telemedicine to achieve greater value. PATCH could serve as an online triage tool to determine if patients undergo a tele-consultation or in-person consultation for anaesthetic referral. With an average patient wait-time of 24 min at the preoperative evaluation clinic (unpublished data from internal audit), conversion of physical to teleconsultation could improve patient experience and clinic efficiency. The clinic could, in turn, focus its resources on optimizing care for medically-complex patients who present physically for consultation. Reducing physical visits to healthcare facilities could also confer the benefit of reducing the transmission of infectious diseases [21] . There are limitations to the present study. Recruitment of a larger sample would have allowed the use of Kappa coefficient for measurement of criterion validity. As the patients' socio-economic characteristics were not reported, we could not control for bias due to socio-economic factors. The study was conducted in young adult female patients of a local healthcare facility. The study may yield As medicines and supplements can affect body functions and interact with anaesthetics, please list all the medicines (including traditional medicines and health supplements) you are currently taking on a regular or daily basis in the last 2 weeks. b -- Have you ever had an operation (including major dental surgery e.g. wisdom teeth extraction)? 89 Poor 4 Are you ever short of breath after walking up two flights of stairs or an overhead bridge? 76 Poor different results in a mixed gender population or another clinical setting. As the application is developed in English, the results may not be extrapolated to questionnaires translated to other languages. Further research is directed at improving validity of the digital application and adapting it for use in other languages. There is also a plan to incorporate decision support tools to aid in risk prediction and clinical decision-making. To maintain the human touch, questions would be developed to simulate human-to-human conversation, incorporating elements of empathy [22] a technique demonstrated to evoke responses more effectively from subjects during a computerised interview. Self-administration of digitized preanaesthesia health assessment is acceptable to patients and reliable in eliciting medical history. Further iteration should focus on improving reliability of the digital tool, adapting it for use in other languages and incorporating clinical decision tools. Practice advisory for preanesthesia evaluation: an updated report by the American Society of Anesthesiologists Task Force on Preanesthesia Evaluation Preoperative clinic visits reduce operating room cancellations and delays Computerization of the preoperative anesthesia interview A comparison of paper with electronic patient-completed questionnaires in a preoperative clinic A computer-assisted preanesthesia interview: value of a computer-generated summary of patient's historical information in the preanesthesia visit Development and assessment of a computer-based preanesthetic patient evaluation system for obstetrical anesthesia Patient-completed, preoperative web-based anaesthetic assessment questionnaire (electronic personal assessment questionnaire PreOperative): development and validation Comparing the history-taking methods used during a preanesthesia visit: the HealthQuiz versus the written questionnaire Use of a patient completed iPad questionnaire to improve pre-operative assessment Validation of a patient selfadministered pre-anaesthetic screening questionnaire Patient's perceptions of an anesthesia preoperative computerized patient interview Computerized model for preoperative risk assessment Outpatient preanaesthesia evaluation clinics Development of an instrument to measure face validity, feasibility and utility of patient questionnaire use during health care: the QQ-10 Validation of a pre-anaesthetic screening questionnaire Patients may respond differently to paper and electronic versions of the same questionnaires Effect of PreAnaesThesia computerized health (PATCH) assessment on duration of nurse-patient consultation and patient experience: a pilot trial Evaluating barriers to adopting telemedicine worldwide: a systematic review Virtualized healthcare delivery: understanding users and their usage patterns of online medical consultations Telehealth transformation: COVID-19 and the rise of virtual care The effects of simulating human conversational style in a computer-based interview Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations The authors would like to thank: Choy Jin Xiang None.Availability of data and materials Data collected and analyzed for the study are available from the corresponding author upon reasonable request.Ethics approval and consent to participate Ethics approval and consent to participate was provided by the Nanyang Not applicable. None.Author details 1 Centre for Population Health Sciences, Lee Kong Chian School of Medicine, Nanyang Technological University (Singapore), Singapore, Singapore.