key: cord-0719827-fjkagpr7 authors: Smolinska, Agnieszka; Jessop, David S.; Pappan, Kirk L.; De Saedeleer, Alexandra; Kang, Amerjit; Martin, Alexandra L.; Allsworth, Max; Tyson, Charlotte; Bos, Martine P.; Clancy, Matt; Morel, Mike; Cooke, Tony; Dymond, Tom; Harris, Claire; Galloway, Jacqui; Bresser, Paul; Dijkstra, Nynke; Jagesar, Viresh; Savelkoul, Paul H. M.; Beuken, Erik V. H.; Nix, Wesley H. V.; Louis, Renaud; Delvaux, Muriel; Calmes, Doriane; Ernst, Benoit; Pollini, Simona; Peired, Anna; Guiot, Julien; Tomassetti, Sara; Budding, Andries E.; McCaughan, Frank; Marciniak, Stefan J.; van der Schee, Marc P. title: The SARS-CoV-2 viral load in COVID-19 patients is lower on face mask filters than on nasopharyngeal swabs date: 2021-06-29 journal: Sci Rep DOI: 10.1038/s41598-021-92665-3 sha: d0af91b2fa3cdd72bfd3e4e67efc7507592a439a doc_id: 719827 cord_uid: fjkagpr7 Face masks and personal respirators are used to curb the transmission of SARS-CoV-2 in respiratory droplets; filters embedded in some personal protective equipment could be used as a non-invasive sample source for applications, including at-home testing, but information is needed about whether filters are suited to capture viral particles for SARS-CoV-2 detection. In this study, we generated inactivated virus-laden aerosols of 0.3–2 microns in diameter (0.9 µm mean diameter by mass) and dispersed the aerosolized viral particles onto electrostatic face mask filters. The limit of detection for inactivated coronaviruses SARS-CoV-2 and HCoV-NL63 extracted from filters was between 10 to 100 copies/filter for both viruses. Testing for SARS-CoV-2, using face mask filters and nasopharyngeal swabs collected from hospitalized COVID-19-patients, showed that filter samples offered reduced sensitivity (8.5% compared to nasopharyngeal swabs). The low concordance of SARS-CoV-2 detection between filters and nasopharyngeal swabs indicated that number of viral particles collected on the face mask filter was below the limit of detection for all patients but those with the highest viral loads. This indicated face masks are unsuitable to replace diagnostic nasopharyngeal swabs in COVID-19 diagnosis. The ability to detect nucleic acids on face mask filters may, however, find other uses worth future investigation. assays for reactive antibodies and viral antigens, and technologies such as computed tomography (CT) scans, biosensors, genetic sequencing, immunoassays, smartphone sensors, and others have been developed 2-5 . Breathing, talking, singing, and coughing release respiratory droplets with a range of sizes and masses 6, 7 . Exhaled droplets can transmit SARS-CoV-2 and, with sufficiently high viral loads and exposures, can lead to new COVID-19 infections. Larger coarse aerosols have limited airborne range before they fall to the ground 8 . Smaller fine breath aerosols can transport respiratory viruses through the air over long distances and, since airborne SARS-CoV-2 has a half-life of hours, appear to contribute to COVID-19 infections in some circumstances [9] [10] [11] [12] . Three main routes for respiratory virus transmission are direct contact with an infected person or contaminated surface, encounters with coarse aerosols surrounding an infected individual, and contact with fine aerosols 12 , which become more dilute with increasing distance from the source in well-ventilated conditions 13 . For most cases of COVID-19 the mode of viral transmission is not known and so debate continues about the relative contribution of the three major routes to disease spread. COVID-19 infection via airborne transmission of SARS-CoV-2 depends on variables such as aerosol size, viral load, half-life of aerosolized virus, and level of aerosol-generating activity 14 . Nasopharyngeal swabs (NPS) are the dominant sample matrix for nucleic acid amplification tests for COVID-19 diagnosis 2 . Another area of interest is the potential to use air filtration materials from personal protective equipment (PPE), such as face masks or respirators, for diagnostic testing as demonstrated for rhinovirus and influenza detection 15, 16 . Recent work has shown that the coronavirus load emitted by symptomatic individuals into the environment is lower when wearing than not wearing a mask 17, 18 . The research by Leung et al. showed that face masks were very effective at reducing the already low level of viral shedding in both coarse (> 5 µm diameter) and fine (≤ 5 µm diameter) exhaled aerosols of symptomatic individuals 17 . The results suggest that surgical masks could prevent transmission of human coronaviruses and influenza viruses and imply that face masks retain viral particles and, therefore, may be suitable for virus detection. To understand whether filters embedded in PPE can be used to detect SARS-CoV-2, a trial to test the hypothesis that face mask filters are non-inferior to NPS for quantitative polymerase chain reaction (qPCR)-based detection of SARS-CoV-2 was conducted. For that purpose, a nebulizer test system was developed for the controlled generation of small aerosol particles and used to disperse inactivated coronaviruses (SARS-CoV-2 and HCoV-NL63) onto electrostatic filters to measure the limit of detection. Following laboratory-based testing of filters for SARS-CoV-2 detection, hospitalized patients with confirmed COVID-19 were recruited to give samples for comparative diagnostic testing of non-invasive samples collected by breathing into a face mask with NPS by a nucleic acid amplification workflow. COVID-19 patient recruitment, ethics, and confidentiality. This study (ClinicalTrials.gov Identifiers: NCT04467112, NCT04508556) was initiated by Owlstone Medical Ltd. as a non-inferiority trial to compare the diagnostic accuracy of samples collected on face mask filters with standard of care NPS samples tested by quantitative reverse transcription-polymerase chain reaction (qRT-PCR). The identity of sample donors was known only to the clinical staff involved in patient care and sample collection. Samples were assigned anonymous sample identifiers and no patient-identifying information was shared with Owlstone Medical or external testing affiliates. Patients were recruited from university hospitals and each site received written ethics approval for protocols complying to the Declaration of Helsinki and local regulations for clinical research; the approval details are as follows: United Kingdom (NHS HRA London-Camberwell St Giles Research Ethics Committee REC reference: 20/LO/0581), Netherlands (Advisory Committee for Scientific Research approval number: ACWO 20u.420/JW/ WO 20.139), Belgium (Comité d'Ethique Hospitalo-Facultaire Universitaire de Liège Nr belge: B7072020000007), and Italy (Comitato Etico Regionale per la Sperimentazione Clinica della Regione Toscana approval number: 18099_bio). In-hospital patients with confirmed COVID-19 were asked to participate in this study and provided informed consent. Patients were eligible to participate if they were older than 18 (> 16 years in the UK), had a positive COVID-19 diagnosis by NPS qRT-PCR, and were able to provide face mask filter and follow-up NPS samples. Patients requiring oxygen via a mask, needing > 4 L/min oxygen via nasal cannula, deemed at risk of Type II respiratory failure, receiving inotropic medications, or who could not provide consent or could not understand and comply with the instructions for breath sample collection were excluded. Construction and validation of an aerosol generating system. An OMROM NE-U780 ultrasonic nebulizer was used to produce a steady stream of aerosolized fluid from a reservoir (Fig. 1) . The generated aerosol concentration was around 8 × 10 4 particles/cm 3 which was then diluted to 2.2 × 10 4 particles/cm 3 using two split-flow dilution sections. A Welas 2100 HP optical particle counter was used to characterize the aerosol. To avoid contamination of the particle counter, only deionized water and buffer solution, without virus, were aerosolized and measured. Since the aerosolization rate and droplet size is dependent on viscosity, surface tension, and density, the generated aerosol showed little variation with the introduction of a trace amount of virus. The particle counter drew, via a vacuum pump, a constant 5 L/min of diluted aerosol/air mixture through a detection chamber and the particles were sized by optical scattering. The measured particle size counts were placed into 59 logarithmically spaced bins between 0.143 and 10.0 µm. The aerosol particle distributions were measured at two different distances, 5 cm and 30 cm, between the dilution region and the particle counter to measure the evaporation of the droplets when mixed with ambient air. The 5 cm path length corresponded to shortest distance for which it was feasible to connect the split flow to the particle counter whereas 30 cm represented fixed distance between dilution region and the filter based on the constraints of the filter holder. www.nature.com/scientificreports/ The aerosol, as produced by the nebulizer and measured 5 cm from the dilution region, had a concentration of 7.5 ng/cm 3 and a mean particle size by mass of 2.4 µm. The same aerosol when measured 30 cm from the dilution region had a concentration of 2.4 ng/cm 3 and a mean particle size by mass of 0.86 µm. This corresponds to a threefold decrease in measured aerosol mass, which agrees with work done by Morawska et al. 19 . Dispersion of coronaviruses onto filters. Dispersion of aerosolized virus on filters was accomplished by replacing the particle counter by an assembly that housed an electrostatic filter (Fig. 2, Supplementary Fig. 1 ). The distance from the filter to the split-flow dilution region was 30 cm, and hence the droplets underwent evapo- Figure 1 . An aerosol generating system connected to a particle counter was used to characterize aerosols. Particles generated by aerosolizing a test solution using an OMRON nebulizer were mixed with air and sized with a Welas particle counter. www.nature.com/scientificreports/ ration to a smaller size. 5 L/min of diluted aerosol/air mix was drawn through the electrostatic filter via a vacuum pump to achieve the same flow conditions as measured by the particle counter. All exhausts were filtered to prevent viruses from reentering the system from the ambient intake. Inactivated SARS-CoV-2 and HCoV-NL63 viruses were diluted with DMEM propagation medium to final known concentrations. CoV-2 is the coronavirus behind COVID-19 whereas human coronavirus HCoV-NL63 is a coronavirus that causes common-cold symptoms in vulnerable populations 20 . SARS-CoV-2 and HCoV-NL63 were propagated and inactivated (Supplementary Method 1). The inactivated viruses were diluted in DMEM medium to 5000, 500, 50, and 5 copies/µL, and 5 min of aerosolization was calculated to lead to the expected delivery or 1000, 100, 10, and 1 copy/filter, respectively. Testing of each dilution was performed in six replicates and included a DMEM-only blank between each dilution. Viral RNA was extracted from filters by adding 4 mL of lysis buffer (Chemagic Viral Lysis Buffer (CMG-832); PerkinElmer Chemagen Technologie GmbH) and vortexing the sample for 2 min. Three-hundred-fifty microliters of the sample extract were used for RNA extraction (FavorPrep Tissue Total RNA Isolation Kit; Favorgen) and eluted in 80 µL. Subsequently 5 µL were used for qRT-PCR (QuantStudio5). RNA standard curves. Isolated RNA (Covid-19 and HCoV-NL63; PAMM) was used to make (tenfold) serial dilutions in RNase-free water (from 10 8 to 10 copies/µL). 5 ul of each dilution was used for qRT-PCR in order to monitor reverse transcriptase efficiency. DNA standard curves. Plasmid DNA (pEX-A128-nCoV_all; 3033 bp; Eurofins and p1055; pGEM-Teasy containing HCoV-NL63 sequences) was diluted to 10 10 copies/µL. This stock solution was used to make (tenfold) serial dilutions and served as a PCR control. qRT-PCR cycle threshold (Ct) calibration curves for SARS-CoV-2 and HCoV-NL63 viral RNA were generated using 100 µL of inactivated virus sample in DMEM medium for RNA isolation followed by elution in 100 µL RNase-free H 2 O. These RNA isolates were serially diluted to obtain concentrations of 10 to 10 9 copies/µL to make standard Ct curves for qRT-PCR of SARS-CoV-2 and HCoV-NL63. Face mask filter and nasopharyngeal swab collection. Samples were collected from 48 individuals who provided consent to participate in the project. PPE-wearing clinical personnel supervised patients in fitting the face mask, holder, and head strap assembly. Patients placed the face mask over nose and mouth and then secured the fit by adjusting the fasteners on the head straps attached to the plastic face mask holder. Patients were instructed to breath normally into the face mask for between 30 and 60 min during which they were asked to cough 10 times and speak out loud for 1 min. The duration of the breath sampling session was entered into the electronic case report form. Following collection of the exhaled breath sample, the head straps were loosened, and the face mask removed. The electrostatic filter (Hollingsworth Technostat T150/15), removed from the face mask using forceps, was deposited in a leakproof polypropylene container containing 4 mL of DNA/RNA Shield (Zymo Research, Irvine, CA, USA). Shortages of leakproof containers, due to worldwide COVID-19 demand, led to the need for filters from one site to be stored at − 80 °C and shipped frozen, without DNA/RNA Shield, following collection. Testing of face mask filters extracted immediately or extracted 5 days after being stored in the dry, frozen state did not reveal any statistically significant differences in qRT-PCR Ct values ( Supplementary Fig. 2 ). After breath sample collection, clinical personnel collected NPS samples which were placed in a polypropylene vial containing 1 mL of DNA/RNA Shield after collection. Follow-up NPS samples were not collected for 8 patients, leading to incomplete results (Supplementary Data). Filters and NPS samples in DNA/RNA Shield were shipped at ambient temperature to a reference laboratory for SARS-CoV-2 testing. Samples stored in DNA/ RNA Shield were shipped in 6 separate batches from October 2020 to December 2020. The ambient temperature range over those 6 dates and locations spanned a low of 27° F (− 3 °C) and high of 57° F (14 °C). Filters collected without DNA/RNA Shield were frozen after collection and were shipped to the testing laboratory on dry ice. For RNA isolation, a 300 µL aliquot of the DNA/RNA Shield solution was taken from NPS and filter samples, except for filters that were stored and shipped in the dry, frozen state. The dry, frozen filters were soaked in 4 mL of Chemagen lysis buffer before aliquoting 300 µL for RNA isolation. RNA was isolated using a Chemagic-360 instrument (PerkinElmer) and Chemagic Viral DNA/RNA kits (cat. no CMG-1033-S) with an elution volume of 100 µL. SARS-CoV-2 qRT-PCR was performed using the SARS-CoV-2 RT-qPCR kit (PerkinElmer; cat. no. 3501-0010). Using primers provided in the kit, SARS-CoV-2 Orf1ab and nucleocapsid (N) gene were amplified as targets according to the manufacturer's instructions and along with nCoV internal standard, nCoV positive, nCoV negative controls provided in the kit. Aerosol generating system particle mass, size, and distribution. Prior to assessing the efficacy of virus capture by filters in the test rig, the aerosols produced by the OMROM NE-U780 ultrasonic nebulizer were characterized. This was accomplished using a Welas 2100 HP particle counter connected at two different path lengths, 5 cm and 30 cm, to measure the size of particles as influenced by evaporative loss over the distance traveled. Aerosols traversing the 5 cm path yielded a relatively broad distribution of sizes compared to the 30 cm www.nature.com/scientificreports/ path (Fig. 3) . The respective aerosol concentrations of particles traversing the 5 cm and 30 cm paths were 7.5 and 2.4 ng/cm 3 , with mass mean diameters of 2.4 and 0.9 µm, respectively. Based on these results, it was calculated that 0.2 µL of aerosolized media from the nebulizer would be delivered over a period of 5 min, with evaporation differences across the two paths lengths changing the final particle size but not the number of virus particles delivered. tions of SARS-CoV-2 and HCoV-NL63 in DMEM were prepared and aerosolized onto filters for 5 min. Standard curves for qRT-PCR were generated and the resulting linear regression equations were used to calculate the number of copies of the respective viruses based on the measured Ct value. Relative to the expected number of virus copies, it was observed that the limits of detection for SARS-CoV-2 and HCoV-NL63 were each around 10 copies/filter (Table 1) . DMEM blanks without virus did not yield a Ct value in qRT-PCR in either SARS-CoV-2 or HCoV-NL63 aerosolization studies. The half-life of SARS-CoV-2 on filters, as evaluated by qRT-PCR, following aerosolization was studied to understand the stability of the virus on dry filters at ambient temperature. To investigate virus half-life, filter samples exposed to SARS-CoV-2 aerosols of 5000 copies/µL were immediately extracted with lysis buffer (0 h) or stored on filters at room temperature for 24 h, 48 h or 72 h before adding lysis buffer and storing at − 80 °C until qRT-PCR testing. The virus stability was tested in two different manners. The first experiment (n = 3) investigated the viral stability on dry filter and the second experiment (n = 6) additionally tested whether viral stability on filter was influenced by prior exposure of the filter to breath. Prior to virus aerosolization in the second experiment, face mask filters were exposed to exhaled breath aerosols for 30 min, dried, then used for aerosolized virus stability testing. As shown in Fig. 4 for breath pre-exposed filters, the Ct values for SARS-CoV-2 qRT-PCR showed an increasing trend from time 0 to 48 h. Translated into copy numbers, the Ct values at 0 and 48 h correspond to 1511 and 1008 on-filter copies of SARS-CoV-2, respectively, compared to the expected on-filter copy number of 1000. Although, the Wilcoxon rank sum test indicated statistical differences between time 0 and 48 h (p-value 0.006), the Ct values obtained at 48 h suggest that a sufficient viral load is Figure 3 . Particle mass distributions were measured based on two dilution path lengths. The particle probability density by mass (dM/M/dx) at a given particle diameter was measured by an optical particle counter placed 5 or 30 cm from the dilution region. The mass mean particle size (dashed line) was 2.4 µm and 0.9 µm when measured at 5 and 30 cm from the dilution region, respectively. The total collection efficiency by mass of the aerosol by the filter was > 99.8% (see Supplementary Fig. 4 ). Supplementary Fig. 3 ). prior confirmed COVID-19 diagnosis were invited to participate in this study, and 48 subjects who provided consent were enrolled for the collection of breath samples. Out of those collected, samples from 1 patient were excluded from the final analysis due to the failure to recover any liquid volume from the electrostatic filter treated with DNA/RNA Shield, and follow-up NPS samples were not available for 8 subjects. Exhaled breath samples were collected by breathing through a face mask containing an embedded electrostatic filter (Fig. 5) . The average age of the 47 patients included in the final analysis was 63 years, and 14 were female and 33 were male ( Table 2 ). Forty percent of participants reported a cardiovascular comorbidity, more than a third had pulmonary comorbidities, and about one-fifth had diabetes. Shortness of breath (average duration 10.8 days), cough (average duration 11.5 days), and fever (average duration 6.9 days) were present in 81%, 57%, and 26% of patients. (Table 3 ) yielding a sensitivity of 8.5% with respect to the initial NPS SARS-CoV-2 qPCR test result. The patients with a positive SARS-CoV-2 test result from filter testing tended to be younger than those with a negative filter result, mean of 38 and 65 years old, respectively, and, on average, had more recent onset of symptoms such as fever, mean of 3.7 versus 8.0 days and shortness of breath, mean of 4.0 versus 11.3 days, respectively, among those with symptoms (Table 2) . However, statistical comparisons between the filter qRT-PCR positive and negative groups were not performed to avoid false discovery due to the low number of positive results and unbalanced group sizes. Since most patients in the study were diagnosed outside the hospital, follow-up NPS samples were collected shortly after face mask filter samples to offset possible skewing of test results due to a lag between filter and NPS sample collection In the present study, we investigated whether, in addition to preventing SARS-CoV-2 virus spread, filters embedded in some types of face masks and respirators could be used for SARS-CoV-2 detection. However, the sensitivity of SARS-CoV-2 detection when using samples extracted from filters was less than 10% of that of the nasopharyngeal swab samples used as a benchmark in this study. Face mask filters are effective at capturing aerosols-even particles with submicron diameters (Supplementary Fig. 4) -and, using inactivated aerosolized SARS-CoV-2, we demonstrated a limit of detection on filters of www.nature.com/scientificreports/ around 10 copies/filter (Table 1) . Furthermore, SARS-CoV-2 was detected on face mask filters for up to 48 h when stored dry at room temperature. Others have shown that SARS-CoV-2 can survive on dry filter paper at room temperature but with severely reduced infectivity by day 3; it is worth noting that qRT-PCR Ct values increased progressively from day 0 in that study 21 . Previous work with exhaled breath captured on filters indicated that a small percentage (24%) of patients infected with human rhinovirus are high particle producers (HPP) whereas the majority are low particle producers (LPP)-with respective geometric means for the HPP and LPP groups of 3500 and 7.4 particles per liter of exhaled breath 15 . The authors mused that if the small airways of HPPs were infected with virus, they would be more likely to generate infectious aerosols and be likely super-spreaders. However, in their study, as in ours, no follow-up epidemiological contact tracing information was available to evaluate a possible HPP-superspreading link. Although virus particles were detected by the optical particle counter in their breath collection system and infection was confirmed by nasal lavage, no rhinovirus RNA was detected within the limits of the qPCR assay. Similarly, an optimized PCR detection method identified influenza RNA in just 4 of 12 breath samples collected on Teflon filters from influenza patients, which translated to a detection range of < 48 to 300 copies of influenza virus RNA per filter in the 4 positive samples 16 . The authors showed that > 99% of the exhaled particles were < 5.0 µm in diameter which suggested that influenza virus may be contained in fine aerosols generated by tidal breathing. The low rate of detection of SARS-CoV-2 from COVID-19-confirmed patients in our study closely mirrors the detection rate of rhinovirus and influenza RNA on filters in these previous studies. The patients with positive SARS-CoV-2 qRT-PCR results from filters were generally younger and had a more recent onset of fever and shortness of breath than the patients with negative qRT-PCR filter results. SARS-CoV-2 viral load peaks about 1 day before onset of symptoms and remains relatively high for first 3-4 days after symptom onset 22, 23 . This suggests that respiratory droplets captured on filters from patients at the highest level of virus shed can be used for SARS-CoV-2 detection. Operationally, several investigators have adopted indirect classifications of SARS-CoV-2 viral load based on NPS qPCR Ct values where Ct < 25, 25-30, or > 30 have been respectively defined as high, intermediate, or low viral load 24, 25 while others have expressed definitions as airborne concentrations 26 , or copies of viral RNA shed 27 . However, it must be stressed that Ct values reflect viral RNA levels and may not be a true indication of infectiousness 25 . Ct values are influenced by respiratory shedding rate and natural history of infection 25 , and, problematically, SARS-CoV-2 viral load peaks before symptoms appear 22, 23 . However, a study of 100 PCR-confirmed COVID-19 patients in Singapore found that PCR Ct values ≤ 30 were significant predictors of viral culture isolation, duration of sickness, and indicated that lower PCR Ct values early in illness was associated with virus viability 28 . At least one report has shown a contradictory trend where non-hospitalized COVID-19 patients had higher viral loads than patients who were admitted to the hospital, but it was noted that the non-hospitalized patients were tested, on average, on day 3 of symptoms whereas the hospitalized cohort averaged 5 days 29 . While the results show that SARS-CoV-2 testing of filters is less sensitive than NPS, there are limitations to the study worth noting. The electrostatic filters used in this study readily absorb liquid and, compared to NPS, required a fourfold greater volume to recover enough liquid to enable RNA extraction. Three patients had matched filter and NPS samples that yielded Ct values (Supplementary Data). In the case of the filters, two of the Ct values were below 40 and considered as positive SARS-CoV-2 results whereas one was above 40 and was defined as negative. The average Ct values for these pairs of filters and NPS were 39.85 ± 2.15 and 28.11 ± 3.75, respectively. In the absence of differences in extraction efficiency between filter and NPS samples, a fourfold dilution due to the different extraction volumes would account for 2 doubling cycles at most, but the difference observed between filters and NPS was 11.8 Ct units. These results indicate that the different volumes of DNA/ RNA Shield used for storing samples were not the major factor contributing differences in sensitivity between filters and NPS. The number of days patients exhibited symptoms of fever, shortness of breath, and coughing averaged from 3.7 to 7 days in patients (n = 4) with positive SARS-CoV-2 qRT-PCR filter results but was 8.0-11.7 days in the filter negative group (n = 43) which indicates that the filter SARS-CoV-2 positive group was earlier in the infection cycle and at a higher point of virus emission 22, 23 . Of the 4 COVID-19 patients with a positive SARS-CoV-2 filter result, 2 did not have a follow-up NPS sample for SARS-CoV-2 qRT-PCR testing and, overall, 8 of the enrolled patients did not have follow-up NPS samples available, so the final performance comparison matrix was based on fewer patients (Table 4) . Although there was an apparent different in average age, 38 versus 66, respectively, between the SARS-CoV-2 qRT-PCR filter positive and negative groups, statistical testing between groups was not performed to avoid false discovery based on the small number of positive cases. Most patients were diagnosed with COVID-19 outside of the hospital in this study, and the time interval between the initial SARS-CoV-2 positive NPS sample and collection of the face mask filter sample was not known for 27 out of the 47 www.nature.com/scientificreports/ patients. Finally, a shortage of leakproof containers meant that 20 of the filters were frozen after collection rather than immersed in DNA/RNA Shield. While all 4 filters that tested positive for SARS-CoV-2 came from samples treated with DNA/RNA Shield following collection, a secondary research endpoint to examine the microbiome captured on face mask filters showed equivalent phyla representation on frozen versus DNA/RNA Shield-treated filters indicating similar nucleic acid integrity regardless of post-collection treatment. During the writing of this manuscript, two important studies reported the use of face mask filters for detection of SARS-CoV-2 30, 31 . In one study, 38% of polyvinyl-alcohol (PVA) strips embedded in face masks yielded positive SARS-CoV-2 qRT-PCR results in confirmed COVID-19 patients 30 and 42% of dissolvable gelatin filters attached to N-95 face masks tested positive for SARS-CoV-2 by qRT-PCR in COVID-19 patients in the other study. While the rate of positive SARS-CoV-2 detection of filters was higher in both studies compared to the present work, it was noted that patients were predominantly sampled within 24 30 to 36 31 h from first known positive NPS SARS-CoV-2 result which differs from our study where a majority of patients were first diagnosed outside of the hospital. The number of days since onset of symptoms and viral load detected on PVA face mask filters were inversely correlated and the 4.2 day average onset of symptoms in COVID-19 with positive PVA SARS-CoV-2 qRT-PCR results 30 closely mirrors the average days of symptom onset in the 4 COVID-19 patients with positive SARS-CoV-2 qRT-PCR results in our study ( Table 2 ). As with our study, SARS-CoV-2 qRT-PCR Ct values were higher on filters compared to matched NPS from the same subject 31 . Altogether, these results underscore that the ability to detect SARS-CoV-2 on face mask filters is restricted to the early disease course when exhaled viral load is near a maximum. Interestingly, while face mask filters do not offer enough sensitivity for practical SARS-CoV-2 (this study), rhinovirus 15 , and influenza 16 detection, there is robust evidence for face mask sampling for the detection of Mycobacterium tuberculosis. A recent prospective observational study showed that face mask sampling on a gelatin filters was an efficient, non-invasive method for detecting M. tuberculosis and did so with greater consistency and at an earlier disease stage than sputum sampling 32 . Thus, there is potential for face mask filter sampling to diagnose tuberculosis and other bacterial infections and the ability to do so non-invasively holds promise for community-based testing. Spread of SARS-CoV-2 in respiratory droplets comprised of fine and coarse aerosols is an important route of transmission 22, 23 . Although, the limit of detection of filters in this study was close to 10 copies/filter, diagnostic testing of face mask filters showed poor concordance between filters and NPS samples in the qRT-PCR detection of SARS-CoV-2 in confirmed COVID-19 patients. We detected SARS-CoV-2 RNA on 4 of 47 face mask filters worn by confirmed COVID-19 patients. The results indicate that face mask filters are not sensitive for routine SARS-CoV-2 detection in COVID-19 patients, but, as reported previously for rhinovirus 15 and influenza 16 , SARS-CoV-2 can be detected in some instances. The lesser sensitivity indicates that face mask filters are inferior to NPS for detection of SARS-CoV-2. Future work may reveal greater diagnostic sensitivity of face mask filters for SARS-CoV-2 detection in pre-symptomatic populations or patients infected with bacteria or fungi such as Mycobacterium tuberculosis, Aspergillus species, or Pseudomonas aeruginosa. COVID-19 vaccine tracker COVID-19 diagnosis-A review of current methods Recent biotechnological tools for diagnosis of corona virus disease: A review COVID-19: molecular and serological detection methods Diagnostic techniques for COVID-19 and new developments The role of respiratory droplet physicochemistry in limiting and promoting the airborne transmission of human coronaviruses: A critical review First10EM blog Airborne transmission of SARS-CoV-2: Theoretical considerations and available evidence Evidence of long-distance droplet transmission of SARS-CoV-2 by direct air flow in a restaurant in COVID-19 patients in earlier stages exhaled millions of SARS-CoV-2 per hour The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission COVID-19 transmission-up in the air Aerosol transmission of SARS-CoV-2: Physical principles and implications. Front. Public Health 8, 590041 Origin of exhaled breath particles from healthy and human rhinovirus-infected subjects Influenza virus in human exhaled breath: An observational study Respiratory virus shedding in exhaled breath and efficacy of face masks Low-cost measurement of face mask efficacy for filtering expelled droplets during speech Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities The novel human coronaviruses NL63 and HKU1 Survival of SARS-COV-2 under liquid medium, dry filter paper and acidic conditions Transmission of SARS-CoV-2: A review of viral, host, and environmental factors Epidemiology of SARS-CoV-2 Impact of viral load at admission on the development of respiratory failure in hospitalized patients with SARS-CoV-2 infection Association between upper respiratory tract viral load, comorbidities, disease severity and outcome of patients with SARS-CoV-2 infection Estimation of viral aerosol emissions from simulated individuals with asymptomatic to moderate coronavirus disease 2019 Wrong person, place and time: viral load and contact network structure predict SARS-CoV-2 transmission and super-spreading events Viral dynamics and immune correlates of COVID-19 disease severity Association of initial viral load in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) patients with outcome and symptoms Exhaled SARS-CoV-2 quantified by face-mask sampling in hospitalised patients with covid-19 Non-invasive sampling using an adapted N-95 mask: An alternative method to quantify SARS-CoV-2 in expelled respiratory samples and its implications in transmission Exhaled Mycobacterium tuberculosis output and detection of subclinical disease by face-mask sampling: Prospective observational studies The views expressed are those of the authors and not necessarily those of the NIHR or the Department of Health and Social Care. The NIHR Cambridge Biomedical Research Centre (BRC) is a partnership between Cambridge University Hospitals NHS Foundation Trust and the University of Cambridge, funded by the National Institute for Health Research (NIHR) All data generated or analyzed during this study are included in this published article (and its Supplementary Information and Supplementary Data files). Correspondence and requests for materials should be addressed to M.P.S.Reprints and permissions information is available at www.nature.com/reprints.Publisher's note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.