key: cord-0717275-mojc9p8k authors: Hunziker, P. title: Minimizing exposure to respiratory droplets, 'jet riders' and aerosols in air-conditioned hospital rooms by a 'Shield-and-Sink' strategy date: 2020-12-16 journal: nan DOI: 10.1101/2020.12.08.20233056 sha: b058f6f655dd2f11f0ae236f36217e888d710252 doc_id: 717275 cord_uid: mojc9p8k Background: In COVID-19, transfer of infectious respiratory materials through cough, respiration and air conditioning is considered critical for disease transmission but the interplay of droplet and aerosol physics, physiology and environmental factors is not fully understood, potentially hindering effective source control. We studied transport modes of respiratory secretions and derived effective strategies for exposure minimization. Methods: Computer simulations and real-world experiments were used. Computational modeling integrated an intensive care setting, multi-physics, and physiology. Patient-focused airflow management and air purification strategies for exposure prevention were examined computationally and validated by submicron particle exhalation imaging. Findings: Ejected respiratory materials exhibited four transport modes: long-distance ballistic, short-distance ballistic, 'jet rider', and aerosol modes. Interaction with the air flow induced by air conditioning contaminated an entire hospital room rapidly. Different than droplets or aerosols, 'jet rider' particles travelled with the turbulent air jet initially, but fell out in reduced air velocity, were not well eliminated by air conditioning and exposed locations and persons at larger distance and longer time than larger droplets or aerosols; the size of jet rider particles predisposes them to preferential capture in the nasal mucosa, the primordial COVID-19 infection site. 'Cough shields' captured large droplets but induced lateral dispersion of aerosols and jet riders. An air purification device alone had limited efficacy. A 'Shield and Sink' approach combining 'cough shields' with 'virus sinks' reduced exposure of bystanders from all droplet sizes in modeling, with supportive evidence in particle imaging. Interpretation: 'Jet riders' have characteristics of highly efficient respiratory infection vectors and may play a role in Covid19 transmission inside rooms. Exposure to all droplet types can be minimized by source control through an easily implemented 'Shield and Sink' strategy. 62 Droplet transmission from coughing or sneezing is considered the dominant mode in COVID-19 but current 63 evidence also suggests a role of aerosol-mediated virus transmission 1 , 2 rendering understanding and control 64 of emitted respiratory materials of all sizes desirable. Arguments for a role of aerosols include transmission 65 by asymptomatic persons 3 , 4 , 5 , epidemiologic observations in SARS-CoV-2 6 , 7 , 8 , air sample analysis 9 , 10 in SARS-66 SARS-COV-2 11 and SARS-COV-1 12 , and general observations in virus and bacterial aerosol transmission 13 , 14 , 15 . 67 Controling aerosol transmission may be an adjunct to avoiding droplet transmission for COVID control 16 , 17 , as 68 recently emphasized by many experts 18 . 69 Expiratory droplets, aerosols and submicron particles: Physiological origin, physical aspects, room 70 distribution and persistence 71 Droplets of various sizes are produced when air moves across wet respiratory surfaces during respiring, 72 coughing, sneezing, talking or singing. Droplet number and size mix depend on activity and will influence 73 weight and infectious agent content; also, droplet motion 19 is size-dependent, ranging from ballistic transfer 74 to slip flow to free molecular flow. The multiphase air jets in coughing or sneezing contain various droplet 75 sizes; in small droplets termed aerosols, aerodynamic drag dominates gravity, such that they tend to travel 76 with the air rather than to falling to the ground; in contrast, larger droplets move ballistically due to larger 77 mass and stronger gravitational impact and may transition to aerosols upon water evaporation. 78 Understanding droplet and aerosol mediated disease transmission therefore needs consideration of 79 production, initial acceleration, droplet/aerosol characteristics and behavior of the environment like air 80 motion. 81 Real-life imaging of droplets and aerosols produced by coughing and respiration is possible 20 , 21 , 22 , 23 , but 82 methods have practical limitations. E-cigarette smoke has submicron particle size comparable to respiratory 83 aerosol subpopulations 24 , 25 and is accessible to imaging, so that E-cigarette smoke tracking might enhance 84 understanding aerosol clouds and allow validating theoretical predictions. 85 Source control and personal protective equipment 86 The current emphasis in Covid-19 transmission control is on social distancing, testing, isolation of affected 87 individuals and their contacts, and use of personal protective equipment (PPE). PPE like masks and gowns 88 confer significant protection, but the relevance asymptomatic and presymptomatic transmission and the 89 phenomenon of super spreaders calls would call for broad use of PPEs, and if not worn to the full extent, 90 may lead to partial protection only. Improved source control might contribute to transmission risk reduction 91 particularly in settings where widespread use of full PPE is not feasible. 92 Aim of the study Room ventilation was parameterized according to the existing air conditioning system, with settings ranging 110 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in 10 room air exchanges per hour for a given room. Patient airflow was modeled as air emanating from the 112 mouth of a patient in a semi-recumbent bed position (i.e., cough jet direction upwards with 30° forward tilt) 113 and optional lateral head rotation. Normal respiration and biphasic flow patterns 29 for cough were modeled, 114 with "exhalation", "weak cough" and "strong cough" modeled as peak airflow velocities of 1.5m/s, 10m/s 115 and 20m/s, respectively. A "breathable zone" (typical caregiver head location), was defined from 1/3 to 2/3 116 of room height, with particle density in this zone as surrogate for caregiver exposure, while particles sticking 117 to surfaces or floating near the floor or the ceiling were considered "not breathable". 118 Droplet and aerosol modeling 119 Modeling of droplet and aerosol distribution and dynamics was done in two complementary ways: particle 120 modeling and diffusion modeling. 121 In particle modeling, individual droplets and aerosols were modeled as spheres moving in the air flow that 122 was modeled by fluid dynamics. Physical particle modeling included starting point, ejection velocity at mouth 123 level, ejection angle, aerodynamic drag exerted by the surrounding moving air, including gravitation, random 124 effects and Brownian motion. Droplets were generated in numbers proportional to orifice velocity, in size 125 clusters with mean diameters of 1mm, 100µm, 10µm, 1µm and 0.1µm +/-20%, corresponding to observed 126 droplet sizes in cough 30 and sneezes, down the size of a single virus particle. Terminal velocity for each 127 droplet due to gravity was determined as a function of the Reynolds number. Dynamics for each droplet 128 within the fluid dynamics field were modeled, using both, separate runs for each size cluster as well as 129 combined runs to understand differential distribution and fate of droplets. Droplet impact on surfaces led to 130 sticking of the particle to said surface. Droplets sticking to a surface or exiting the room through exhaust 131 pipes or door were counted. 132 In a convection/diffusion model, complementary to the particle analysis, air contamination by aerosols was 133 modeled as continuous diffusion model, with origin of the solute at the mouth, using particle size to 134 compute the diffusion coefficient. Modeling details are given in the supplement. Real-life imaging of submicron particle distribution on coughing Two habitual E-cigarette smokers were positioned in an ICU bed in the modeled room, instructed to inhale 145 the smoke of their E-cigarette and then to voluntarily cough with moderate strength, and were filmed for 146 digital submicron particle imaging without and with the "Shield and Sink" equipment in different 147 Patient and public involvement Dissemination to participants and data sharing 157 Data have been made available to participants; data will be available as supplementary files. 158 159 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint 1mm droplets up to 4 and 6 m distance during moderate and strong coughs was observed in the particle 170 model, capable to reach the contralateral wall, nurse workplaces and adjacent beds, depending on head 171 rotation. Notably, the upward/forward direction of the cough jet due to the semi-recumbent position 172 essentially doubled the reach of ballistic droplets compared to a horizontal jet direction. Droplets in the 173 0.1mm size range started ballistically but were quickly slowed down by aerodynamic drag and, attracted by 174 gravity, fell down within 1 m around the patient head, such that after the first 3 seconds, most droplets from 175 1 to 0.1mm had hit a surface and were no longer in the air. Droplets in the 10µm size range behaved 176 differently: due to the small size and a high drag/gravity force ratio, they travelled with the air jet for several 177 meters before falling out due to gravity from the slowed down air convection; distance traveled by these 178 droplets even surpassed most large ballistic droplets; they were the main population sprayed on a neighbor 179 bed in a specific setting. A fourth population, the droplets of size 1µm down to 0.1µm showed classical 180 aerosol behavior and travelled throughout with the air convection, not falling out at the studied range of 181 ventilation settings. Such aerosols followed complex trajectories within the room determined by A/C 182 induced air flow patterns, and depending on cough direction and ventilation settings, reached most room 183 locations within a few minutes, before being removed by exiting through the ventilation exhaust, sticking to 184 a wall, or, with the door opened, by leaving through the door to central ICU workplaces. 185 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint The convection-diffusion model yielded complementary results consistent with the aerosol particle modeling 186 and showed that within minutes, in most locations of the room (except downstream of the air conditioning 187 inlet), concentration of aerosols build up and are only slowly cleared (10-20min) by air conditioning, implying 188 that a higher cough frequency leads to accumulation of aerosols. 189 Exposition to various droplet fractions at "breathable locations" over time (Figure 3 ) In the novel Shield & Sink strategy, a shield and a sink were combined based on parameters identified in 207 modeling. Modeling showed that at sufficient sink air flows, the shield bends the streamlines of the cough air 208 flow such to keep the aerosol plume in proximity to the sink device, so that it can be quantitatively captured 209 and filtered by the device. Stepping up from a H13 to a higher performant H14 Hepa filter had a negligible 210 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint additional effect on the results, but higher cough jet velocities increased the proportion of "escaping" 211 aerosol while higher air sink velocity decreased it (data not shown). The added value of air disinfection 212 strategies, e.g. by ultraviolet light was not examined but the results suggest that its potential for incremental 213 benefit to "Shield & Sink" is small. 214 Droplet and aerosol capture strategies in real-life scenario ( Figure 5) 215 Assessing the behavior of exhaled sub-micrometer particles by digital submicron particle imaging of ejected 216 E-cigarette smoke confirmed computational predictions: Coughing rapidly produced a large particle plume, 217 discernibly by eye up to 2 meters in the first seconds, followed by slow further movement. Installing a shield 218 in front of the face led to jet splitting and redirection. Using an air filtration device near the patient's head 219 was incapable to quantitatively remove the aerosol. However, in the "Shield and Sink" strategy, the shield 220 slowed the aerosol jet such that the plume was aspirated and filtered to a visually full degree by the sink perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint The novel "Shield and Sink" approach introduced here is a patient-centered strategy to transmission 234 avoidance by creating per-patient aerodynamic settings, an approach that proves highly effective and 235 achieves near-complete elimination of droplets and aerosol of all classes near the patient head in modeling 236 and real-world experiments, suggesting a potential for strongly reducing exposure of care persons and 237 nearby patients. 238 The quest for source control measures to stop infection propagation Determinants of droplet and aerosol propagation 247 We found that the spread of potentially infectious material from the airways to the environment is highly 248 variable and determined by patient characteristics (coughing strength, head position), droplet size, room 249 geometry and ventilation conditions. Even in ventilation conditions fulfilling current hospital architecture 250 norms, droplet spread reached neighbor patients and nurse workplaces; prolonged aerosol circulation was 251 observed, but increasing ventilation settings was found to potentially increasing room air turbulence, i.e. 252 undesired air mixing. 253 For droplets in the 1 millimeter range, we observed ballistic transfer up to 5-6 meters in strong and 4 m in 254 moderate strength cough jets. The longer reach of droplets compared to the historical 1-2 m rule for droplet 255 transmission has several reasons: First, in ICU and hospital room patients, the frequently used semi-256 recumbent position 32 with head elevation ≥30° directs the cough jet obliquely upwards and thereby 257 maximizes a ballistic trajectory; also, such droplets initially travel with the air jet (i.e., less drag), benefit from 258 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint upward buoyancy of the warm expired air, and dry up slower due to the expired air humidity, enabling them 259 to reach farther than an isolated water droplet horizontally emitted into non-moving dry air. Droplets in the 260 0.1 mm diameter range also behaved ballistically, but their smaller kinetic energy led to quick slowdown by 261 drag as soon as they left the cough air jet, and being pulled down by gravity, their reach was limited to 262 approximately 1m around the head. Typical aerosol behavior (traveling with the surrounding air, flowing 263 around obstacles) was observed for droplets starting at the 1 µm down to the 0.1 µm ranges, consistent with 264 literature; the negligible impact of gravity on such very small droplet combined with the higher temperature 265 of the exhaled air explained their tendency to rise towards the ceiling and being eliminated through the air 266 conditioning exhaust. "Jet rider" droplets, smaller than ballistic droplets but larger than classical aerosols, 267 appeared to have particular importance: 268 269 "Jet Riders" with distant fallout 270 Notably, the size fraction of droplets in the 10-20 (or 5-40) µm range displayed a behavior that does neither 271 fit in the "ballistic" nor in the "aerosol-type" patterns: While it travels in the early, fast, warm, turbulent and 272 buoyant air jet like an aerosol, the gravitational pull becomes dominant in the slower moving air with less 273 turbulence, leading to gravitational fallout at a distance, thereby spraying objects like a neighbor patient bed 274 or nurse workplaces, reaching on average even further than the large ballistic droplets, a finding that may be 275 highly relevant because smaller droplets carry a significant amount of infectiosity 33 , 34 . Unfortunately, this is 276 also the particle size range where the nose, the primordial location of SARS-CoV-2 infection, catches particles 277 highly effectively 35 . 278 While classical fluid dynamics, aerodynamics and droplet physics are well established scientific fields, it 279 appears thus that in the complexities encountered in the interaction of human pathophysiology, viral 280 spread, droplet physics and room air conditioning, some important and interesting phenomena are not yet 281 fully explored, appear relevant for human health and thus merit further in-depth study that may contribute 282 to solving urgent societal problems. 283 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint Hospital air conditioning interval, but on the other side induced more turbulent room air flow at the given geometry, favoring air 291 mixing and thus potentially transporting aerosol-loaded air from non-breathing zones towards breathing 292 zones; therefore, the benefit of just increasing ventilation thus has limitations that depend on the specific 293 characteristics of a room and A/C system. 294 Cough "shields" were partly effective in stopping forward-directed cough droplets but led to a redirection of 296 the air stream carrying aerosols, including in the direction of adjacent beds and nurse workplaces at the side 297 of the patient bed, an effect which is not desired. Also, air flow around obstacles is a well-known physical 298 phenomenon 36 that limits the effectiveness of such shields for aerosol plumes. 299 Air filtering 300 Air purification by filtering with a high flow, HEPA filter equipped commercially available air filtering device, 301 was examined. We found in modeling as well as in real-world experiments (E-cigarette smoke distribution) 302 that such an air filtering device alone, even when positioned near the patient head, only has a limited 303 capabililty for directly and quantitatively removing droplets/aerosols from the cough jet because the jet 304 velocities away from the device were sufficiently high to overcome the modest pressure/velocity gradient 305 produced by the device. Non patient centered air filtering has been shown to contribute to reduction of 306 overall aerosol load in recirculating contaminated room air 37 , but in such that setting, an aerosol 307 concentration half-time in the range of 6-12 minutes was found, similar to the aerosol removal in our 308 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint context by standard A/C. In such devices, quantitative aerosol removal is dominated by air flow, directing 309 flow towards the filter, rather than Hepa filter class (H13: 99.95%; H14: 99.995% particle removal efficacy). 310 "Virus shield and sink" -a novel, effective, per-patient airflow handling approach 311 To achieve near-complete elimination of droplets and aerosols of all sizes from 1mm down to 0.1micrometer 312 from the cough jet and expired air, a novel per-patient airflow handling approach was designed, inspired by 313 the findings above, and was validated in a real-life scenario. 314 Such a per-patient airflow management includes capturing large, ballistic, forward directed droplets by a 315 shield that at the same time works as a jet redirector, limiting the forward velocity of the air jet and 316 redirecting the aerosol plume in a way that it is amenable to being captured by a "virus sink", a strategically 317 placed aur filtering device behind the patient's head driven at velocities tailored to bend the streamlines of 318 the aerosol jet towards the device and quantitatively filter the aerosol. This setup was capable to capture 319 cough-related respiratory materials from millimeter-sized droplets down to submicron particles in a 320 quantitative fashion. 321 E-cigarette smoke test as simple surrogate test for source control measures 322 The efficacy a specific "Shield and Sink" setup tailored to a specific location and filter device that may differ 323 in geometry and air flow capacity from the one described here is a amenable to simple qualitative function 324 testing by the E-cigarette smoke test described here, thus representing a real-world quality control and 325 training tool. 326 Limitations 327 Clinical proof of infection reduction by preventive measures will require large-scale clinical trials that cannot 328 easily be blinded. In the ongoing COVID pandemic, time available for such trials is limited, and clinical trial 329 evidence for most prevention activities will remain sparse. As the approach proposed here is non-invasive, is 330 associated with limited expense, and the current study focuses on a plausible surrogate marker, namely 331 spread of various-sized materials produced by coughing, such a strategy may be clinically introduced with 332 little delay, yielding a safe time window to further in-depth study of the still controversial role of aerosols in 333 All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint COVID transmission by additional methods, e.g. aerosol nucleic acid testing and cell culture infectiosity of 334 exhaled materials. 335 Importance 336 The novel "Virus Shield and Sink" approach for source control of droplets, "jet riders" and aerosols emitted 337 by coughing patients permits significant reduction of the transfer of such potentially infectious materials in a 338 hospital setting. As a rapidly and inexpensively implementable infrastructural measure, it has the potential 339 of contributing to mitigation and control of the COVID pandemic. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint Architectural Modeling Architecture modeling was done within a multiphysics environment ("A2" Framework, "Matrix" library developed in a joint project of the University of Basel and ETH Zurich) by creating a 3D vector geometry model using the software module "VolumeRaytracer"). Regular multiresolution finite difference grids from size 512x256x256 down to 32x16x16 were then overlaid on the volume data for modeling. The fluid dynamics model was based on the same multiphysics framework, module "VolumeNavierStokes" and was typically run on the 256x128x128 grid, with a 16-fold oversampling for particle displays. Fluid dynamics used a Backward Time Centered Space approach and modeled fluid advection, diffusion and divergence using a standard operator splitting approach under the assumption of noncompressibility, also incorporating solute injection at the mouth orifice, solute diffusion as well as heat transfer (orifice exit temperature 37°C) and buoyancy. Aerosol production (modeled in this part as solute injection) was proportional to orifice exit velocity. Diffusion coefficients for spheres of 10um, 1um and 0.1um were 3.0E-8, 3.0E-7 and 3.0E-6 , respectively. Adaptive time stepping was used to limit fluid advection within a step to at most one grid element, resulting in time steps down to 2ms. Measurement probe volumes could be placed within the model to monitor the changes of a local parameter over time. An overall Reynolds number as predictor of turbulent flow conditions was estimated using the room extents and the overall flow, although precise, local Reynolds number in such complicated geometries cannot easily be determined. Particle modeling was done using the same framework, with an object-oriented modeling of each particle in a manner allowing overlay of the particles on the fluid dynamics framework. Specifically, individual droplets and aerosols were considered as spheres with the density of water moving in the air flow that was modeled by fluid dynamics. Physical effects in sphere modeling included ejection velocity at mouth air speed, aerodynamic drag exerted by the surrounding air, gravitational force, and Brownian motion, each including some random variation. Droplets originated at random positions within the orifice, were generated in numbers proportional to the orifice velocity, in size clusters with mean diameters of 1mm, 100µm, 10µm, 1µm and 0.1µm +/-20%, corresponding to observed droplet sizes in cough and sneezes down the size of a single virus particle. Initial velocity corresponded to the fluid dynamics velocity field with added Gaussian noise (sigma=25%) to velocity vector components. Drag and terminal velocity for each droplet was determined based on the drag equation, switching to the terminal velocity creeping flow solution 38 when Reynolds number was <1. Dynamics for each droplet were modeled, in separate runs for each size cluster and in combined runs to understand differential distribution and fate of droplets. Droplet impact on surfaces led to sticking of the particle to said surface. Droplets sticking to a surface or exiting the room through exhaust pipes or door were counted as inhalable in the exposure statistics. The airflow model was similar to the one described in PLOS. In short, on coughing an air jet exited from an orifice (area 5cm 2 ), with a temporal cough flow profile modeled as two-phase event with a first, stronger but short (peak at 0.25 sec) air emission, overlapping with a somewhat longer (peak at 0.5 sec) but less strong air emission, whereby each component was modeled as a cropped (zero to pi) sinus wave, parameterized such that for "strong cough", "moderate cough" and "normal exhalation" mouth orifice peak velocities approximated 20m/s, 10m/s, and 2.5m/s, respectively. All rights reserved. No reuse allowed without permission. perpetuity. preprint (which was not certified by peer review) is the author/funder, who has granted medRxiv a license to display the preprint in The copyright holder for this this version posted December 16, 2020. ; https://doi.org/10.1101/2020.12.08.20233056 doi: medRxiv preprint Particle sizes of infectious aerosols: implications for infection control Consideration of the Aerosol Transmission for COVID-19 and Public Health Presumed asymptomatic carrier transmission of COVID-19 Presymptomatic transmission of SARS-CoV-2-Singapore Substantial undocumented infection facilitates the rapid dissemination of novel coronavirus (SARS-CoV2) Aerosol and surface distribution of severe acute respiratory syndrome coronavirus 2 in hospital wards A choir decided to go ahead with rehearsal. Now dozens of members have COVID-19 and two are dead Why an Idaho ski destination has one of the highest COVID-19 infection rates in the nation. The New Yorker Transmission potential of SARS-CoV-2 in viral shedding observed at the university of Nebraska medical center Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Evidence of airborne transmission of the severe acute respiratory syndrome virus Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises Turbulent gas clouds and respiratory pathogen emissions: Potential implications for reducing transmission of COVID-19 Recognition of aerosol transmission of infectious agents: A commentary it is Time to Address Airborne Transmission of COVID-19 Rapid expert consultation on the possibility of bioaerosol spread of SARS-CoV-2 for the COVID-19 pandemic Violent respiratory events: on coughing and sneezing Airflow dynamics of coughing in healthy human volunteers by shadowgraph imaging: an aid to aerosol infection control Flow visualization of an N95 respirator with and without an exhalation valve using schlieren imaging and light scattering AFM imaging of exhaled microdroplets and dry residues collected by impactor Characterizations of particle size distribution of the droplets exhaled by sneeze Electronic cigarette aerosol particle size distribution measurements Electronic cigarette power affects count concentration and particle size distribution of vaping aerosol Hydrodynamica, sive de Viribus et Motibus Fluidorum Commentarii (Hydrodynamics, or commentaries on the forces and motions of fluids) Basel Swiss Guideline SWKI VA105-01 Ventilation and air conditioning -Part 4: Ventilation in buildings and rooms of health care Human cough as a two-stage jet and its role in particle transport Sizing of Coughs and Sneezes Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1 Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients: a randomised trial Measurements of airborne influenza virus in aerosol particles from human coughs Particle sizes of infectious aerosols: implications for infection control Flow around three-dimensional obstacles in boundary layers Können mobile Raumluftreiniger eine indirekte SARS-CoV-2 Infektionsgefahr durch Aerosole wirksam reduzieren NIH Image to ImageJ: 25 years of image analysis