key: cord-0716740-9ewgnwa1 authors: Mitsunaga, Toshiya; Seki, Yutaka; Yoshioka, Masakata; Suzuki, Ippei; Akita, Kumi; Mashiko, Syunsuke; Uzura, Masahiko; Takeda, Satoshi; Sekine, Akihiro; Mashiko, Kunihiro title: Comparison of the Diagnostic Value of Immunochromatography Kits in Corona Virus Disease 2019 Patients: A Prospective Pilot Study date: 2021-01-14 journal: JMA J DOI: 10.31662/jmaj.2020-0084 sha: 50caae84448612a098c8786a7643fe012983e586 doc_id: 716740 cord_uid: 9ewgnwa1 INTRODUCTION: The spread of coronavirus 2019 (COVID-19) is a serious problem all over the world. Several immunochromatography kits of the antibody for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed, but it is still unclear which kits have high diagnostic value. This study aims to evaluate the accuracy rate for antibody detection of each immunochromatography kit and reveal which kit has a high diagnostic value for antibody detection. METHODS: This study was carried out between 1 August 2020 and 14 October 2020 at the Association of EISEIKAI Medical and Healthcare Corporation Minamitama Hospital. Patients diagnosed with COVID-19 and approximately 30 days after symptom onset were included as the positive group. The serum SARS-CoV-2 antibodies were analysed using seven immunochromatography kits. RESULTS: Twenty samples (Positive group: 10 patients, Negative group: 10 healthy medical workers) were included in this study. The median age of the patients was 44 years, and the median duration from symptom onset was 30.5 days in the positive group. The accuracy rates for IgM/IgG detection were: 90.0%/100% in Kit A; 50.0%/95.0% in Kit B; 55.0%/65.0% in Kit C; 60.0%/55.0% in Kit D; 50.0%/80.0% in Kit E; 80.0%/90.0% in Kit F; and 90.0%/100% in Kit G. CONCLUSIONS: Our study showed that there is a variation of accuracy rates between immunochromatography kits for antibodies of SARS-CoV-2. COVID-19 IgG/IgM RAPID TEST CASSETTE (Hangzhou Biotest Biotech Co., Ltd., China) and Nadal COVID-19 IgG/IgM Rapid Test (BioServUK Ltd., UK: United Kingdom) have high accuracy rates for both IgM and IgG detection. Evidence from large population studies of immunochromatography kits is needed to clarify the details of diagnostic value for SARS-CoV-2. In December 2019, the first group of patients with unknowncaused pneumonia was confirmed in Wuhan, China. The pathogen was detected as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The spread of coronavirus 2019 (COVID-19) was so fast that it has been very difficult to control the further infection of COVID-19 since the World Health Organization declared a pandemic. In Japan, The Ministry of Health, Labor and Welfare of Japan announced 71,856 cases of COVID-19, with 1,363 deaths (mortality rate: 1.89%) confirmed by 7 September 2020 (1) . Studies of severe acute respiratory syndrome (SARS) and Middle East respiratory syndrome carried out by Hsueh et al. and Corman et al. revealed that virus antibodies were detected in more than 80% of patients at two weeks after symptom onset (2) , (3) . Similarly, some reports have shown that SARS-CoV-2 immunoglobulin-M (IgM) and immunoglobulin-G (IgG) positive detection rates gradually increased after infection and reached more than 80% at 15 days after symptom onset, whereas the IgM positive detection rate decreased after 20 days (4) , (5) . On the other hand, a study carried out by Long et al. showed that both the IgM and IgG positive detection rates gradually increased and reached more than 90% in IgM and 100% in IgG at 20 days after symptom onset without a decline of positive detection rates (6) . While several immunochromatography kits for the antibody of SARS-CoV-2 have been developed, it is still unclear which immunochromatography kit has a high accuracy rate for anti-SARS-CoV-2 antibody detection, with there being a variation in antibody-positive detection rates for SARS-CoV-2 between antibody tests. The aim of this study is to evaluate the accuracy rate for antibody detection of each immunochromatography kit and reveal which kit has a high diagnostic value for antibody detection. This prospective pilot single-centre observational study was carried out to evaluate the diagnostic value of immunochromatography kits in COVID-19 patients. The protocol for this research project was approved by a suitably constituted Ethics Committee of the institution and conforms to the provision of the Declaration of Helsinki (Committee of Association of the EISEIKAI Medical and Healthcare Corporation Minamitama Hospital, Approval No. 2020-Ack-05), and written consent was obtained from all the patients. The present study was carried out between 14 August 2020 and 14 October 2020 at the Association of EISEIKAI Medical and Healthcare Corporation Minamitama Hospital, a secondary emergency medical institution. Patients diagnosed as COVID-19 by real-time polymerase chain reaction (RT-PCR) and about 30 days after symptom onset were included in this study as the positive group. Healthy medical workers who did not have an episode of infection for the past six months and whose RT-PCR was negative were included in this study as the negative group. Information on age, sex, duration from onset, symptoms, body mass index, comorbidity, pneumonia, antiviral drugs, inhaled oxygen, and hospitalisation were recorded. The serum SARS-CoV-2 antibodies of the patients were analysed using seven immunochromatography kits. ( (7) Kit G: Nadal COVID-19 IgG/IgM Rapid Test (BioServUK Ltd., UK: United Kingdom). Product information of the seven immunochromatography kits is summarised in Table 1 . Two kits targeted spike protein, three kits targeted nucleocapsid protein, and two kits targeted spike and nucleocapsid protein. Whole blood, serum, or plasma samples can be used as specimens in all kits. Five kits require 10-20 μL of sample volume, but the other kits require only 2 μL or 2-3 drops of a mixture of the sample (25 μL) and diluent. All seven kits detect anti-SARS-CoV-2 IgM and IgG antibodies separately within 10-20 minutes. Cross-reactivity with antibodies to other coronaviruses (HKU1, NL63, OC43, 229E) was confirmed in five kits, and cross-reactivity to Rheumatoid factor was confirmed in two kits. More than half of the kits were not affected by blood compounds or common drugs. According to the recommendation of the manufacturer's instructions, weak positive reactions of kits were considered as positive. Continuous variables were described as medians and interquartile ranges (IQR) and were compared with Mann-Whitney U-test. Categorical variables were described as numbers and percentages and were compared with Fisher's exact test. A p-value of less than 0.05 was considered to indicate statistical significance. Data were analysed in the Statistical Package for the Social Sciences, version 26.0 (SPSS, Chicago, IL, USA). Twenty samples (Positive group: 10 patients, Negative group: 10 healthy medical workers) were included in this study. The median age (interquartile range) of the samples was 44.0 (25.3) years in the positive group and 39.5 (7.0) years in the negative group. Six (60%) samples in the positive group and in the negative group were male. The major chief complaints were fever (8 cases: 80%), fatigue (7 cases: 70%), and cough (6 cases: 60%). The median duration from symptom onset was 30.5 (IQR = 4) days. Four patients (40%) had some comorbidities as follows: hypertension (2 cases: 20%); hyperlipidaemia (1 case: 10%); diabetes mellitus (2 cases: 20%); COPD (chronic obstructive pulmonary disease)/asthma (1 case: 10%); CKD (chronic kidney disease) (1 case: 10%); and liver disease (1 case: 10%). On the other hand, no one had comorbidity in the negative group. Seven patients (70%) were hospitalised in our hospital, one patient (10%) was hospitalised in another hospital, four pneumonia cases (40%) were detected by radiological tests, and one case (10%) was supplied oxygen. One case (10%) was administered Favipiravir, and two cases (20%) were administered Remdesivir ( Table 2 ). In the positive group, the IgM positive detection rates were eight cases (80%) in Kit A, zero (0) cases (0%) in Kit B, one case (10%) in Kit C, two cases (20%) in Kit D, zero (0) cases (0%) in Kit E, six cases (60%) in Kit F, and eight cases (80%) in Kit G. Moreover, the IgG positive detection rates were ten cases Human IgM/IgG Rapid Test (Kit D) (Figure 1) . On the contrary, there was no positive reaction of IgM and IgG in the negative group. Further detailed clinical information of each patient in the positive group is shown in Table 3 , and the details of the reaction for antibodies of SARS-CoV-2 in the positive group are shown in and 100% for IgG detection, respectively. On the contrary, the accuracy rates of Kit B, Kit C, Kit D, and Kit E for IgM detection were low (50%-60%), and those of Kit C and Kit D for IgG detection were also low (55%-65%). In our study, Kit A) COVID-19 IgG/IgM RAPID TEST CASSETTE (Hangzhou Biotest Biotech Co., Ltd., China) and Kit G) Nadal COVID-19 IgG/IgM Rapid Test (BioSer-vUK Ltd., UK: United Kingdom) have a high accuracy rate for detection of anti-SARS-CoV-2 IgM and IgG, and the accuracy rates were 90.0% for IgM detection and 100% for IgG detection. On the other hand, the accuracy rate for anti-SARS-CoV-2 antibodies detection was low in Kit C) Coronavirus (COVID-19) IgM/IgG Rapid Test Kit (RayBiotech Life Inc., US) and Kit D) COVID-19 Human IgM/IgG Rapid Test (Abnova Co., Ltd., Taiwan) (55.0%-65.0%). These results suggest that there is a variation of accuracy rates for anti- To the best of our knowledge, this is the first analysis to compare the diagnostic value in more than five immunochromatography kits for anti-SARS-CoV-2 antibodies in Japan. In this study result showing that the accuracy rate for each kit was determined by false negative rate, the specificity of all the kits was 100%, and the sensitivity varies greatly between each kit. Two parts of protein are well known as the target of antibodies: spike (S) protein and nucleocapsid (N) protein. The S protein comprises S1 domain protein, S2 domain protein, and RNA binding domains protein (7) . The N protein is composed of the N terminal domain and the C terminal domain (8) . With antibodies to the N protein commonly being more sensitive than the S protein antibody for detecting SARS-CoV-2 infection (9) , all the manufacturers provide information on the tar- There might be two reasons for this fact: 1) the accuracy rate of the kits is not related to the target proteins; or 2) the differences of the target proteins that are not shown on the product description are related to the reaction of antibodies. A study carried out by Forster et al. showed that there are several genotypes in SARS-CoV-2 (10) . As SARS-CoV-2 spreads in the world, not only genotypes but also S or N proteins mutate (11) , (12) . The manufacturers developed their rapid antibody kits based on the COVID-19 patients in their own countries, so the mutation of S protein or N protein might be the cause of false negative for the detection of antibodies. The amount of the specimen has been set at 10 or 20 μL in most of the kits. On the other hand, the amount of the specimen is small in Kit B and Kit C. It is considered that the amount of specimen may not be directly related to the antibody detection, as, in this study, the IgG detection rate is as high as 80% despite the small amount of specimen in Kit B, whereas the IgG detection rate is as low as 20% despite the normal amount of specimen in Kit D. The limit of detection has been set in all the kits. However, we obtained the information about the limit of detection in one kit, so we could not compare between several kits. The limit of detection might be set low in the kits that have a high false negative rate. In our study, the number of kits that have antibody-positive reaction was significantly larger in patients older than 40 years (median [IQR]: 3 [0.5] vs. 5.5 [1] , p < 0.05), with a study carried out by Jacofsky et al. showing that antibody was less likely to be produced after COVID-19 infection in a younger population (13) . These results suggest that the concentration of antibodies of SARS-CoV-2 is higher in older patients. In the study carried out by Chen et al., antibody levels were correlated with the severity of COVID-19 pneumonia (14) . On the other hand, the study carried out by Gozalbo-Rovira et al. showed that there was no association between antibodies of SARS-CoV-2 and COVID-19 severity (15) . In our study, the number of kits that have antibodies positive reaction was larger in the patients who had pneumonia, were administered antiviral drugs (Favipiravir or Remdesivir), or were supplied oxygen, but there was no significant difference (median [IQR]: 4 [2] vs. 6 [1] , p = 0.054). These results may show that the concentration of antibodies of SARS-CoV-2 is higher in more severe cases. Based on the above results, it could be said that the cause of the differences in diagnostic ability between each kit was mainly the limit values of the kits and the concentration of antibodies. A study carried out by Jin et al. showed that the positive detection rate of antibody achieved the peak at 26-30 days after symptom onset (5) , so we chose patients diagnosed as COV-ID-19 by RT-PCR and about 30 days after symptom onset as the positive group. Even if the RT-PCR is negative, the possibility of infection with COVID-19 remains. So, as the negative group, we chose healthy medical workers who did not have an episode of infection for the past six months and whose RT-PCR was negative. Our study has several limitations. Firstly, we analysed the patient's serum antibodies of SARS-CoV-2 only at one point, so the change of antibodies in a different phase is unclear. Secondly, the sample size was small, so there could be bias such as age or gender. Thirdly, we did not include the severe cases, and there could be severity bias. Further large-scale studies that evaluate antibodies of SARS-CoV-2 in several phases are needed in the future. In conclusion, our study showed that there is a variation of accuracy rates between immunochromatography kits for antibodies of SARS-CoV-2. COVID-19 IgG/IgM RAPID TEST CASSETTE (Hangzhou Biotest Biotech Co., Ltd., China) and Nadal COVID-19 IgG/IgM Rapid Test (BioSer-vUK Ltd., UK: United Kingdom) had high accuracy rate for both IgM and IgG. Evidence from large population studies of immunochromatography kits is needed to clarify the details of the diagnostic value for COVID-19. None Coronavirus disease 2019 (COVID-19) situation within and outside the country Chronological evolution of IgM, IgA, IgG and neutralisation antibodies after infection with SARS-associated coronavirus Viral shedding and antibody response in 37 patients with Middle East respiratory syndrome coronavirus infection Antibody detection and dynamic characteristics in patients with COVID-19 Diagnostic value and dynamic variance of serum antibody in coronavirus disease 2019 Antibody responses to SARS-CoV-2 in patients with COVID-19 SARS-CoV-2 proteome microarray for global profiling of COVID-19 specific IgG and IgM responses SARS-CoV-2-related data provided by the Protein Domains resource Sensitivity in detection of antibodies to nucleocapsid and spike proteins of Severe Acute Respiratory Syndrome Coronavirus 2 in patients with Coronavirus disease 2019 Phylogenetic network analysis of SARS-CoV-2 genomes Spike mutation pipeline reveals the emergence of a more transmissible form of SARS-CoV-2. bioRxiv Evidence for mutations in SARS-CoV-2 Italian isolates potentially affecting virus transmission Understanding antibody testing for COVID-19 SARS-CoV-2 neutralizing antibody levels are correlated with severity of COVID-19 pneumonia SARS-CoV-2 antibodies, serum inflammatory biomarkers and clinical severity of hospitalized COVID-19 patients JMA Journal is an Open Access journal distributed under the Creative Commons Attribution 4.0 International License. To view the details of this license We are grateful for technical support from the Genesis Healthcare Co.