key: cord-0714533-hlxhjlcp authors: Walsh, C.; Tafforeau, P.; Wagner, W.L.; Jafree, D.J.; Bellier, A.; Werlein, C.; Kühnel, M.P.; Boller, E.; Walker-Samuel, S.; Robertus, J.L.; Long, D.A.; Jacob, J.; Marussi, S.; Brown, E.; Holroyd, N.; Jonigk, D.D.; Ackermann, M.; Lee, P.D. title: Imaging intact human organs locally resolving cellular structures using hierarchical phase-contrast tomography date: 2021-12-01 journal: Nat Methods DOI: 10.1038/s41592-021-01317-x sha: 056b7045a1b00f835ad6fdd915ef4bfe749dbb0c doc_id: 714533 cord_uid: hlxhjlcp Imaging intact human organs from the organ to the cellular scale in three-dimensions is a goal of biomedical imaging. To meet this challenge, we developed Hierarchical Phase-Contrast Tomography (HiP-CT), an X-ray phase propagation technique utilising the European Synchrotron Radiation Facility’s Extremely Brilliant Source (ESRF-EBS). The spatial coherence of the ESRF-EBS combined with our beamline equipment, sample preparation and scanning developments, enabled us to perform non-destructive, 3D scans with hierarchically increasing resolution at any location in whole human organs. We applied HiP-CT to image five intact human organs: brain, lung, heart, kidney and spleen. HiP-CT provided a structural overview of each whole organ followed by multiple higher resolution volumes of interest, capturing organotypic functional units and certain individual specialised cells within intact human organs. We demonstrate the potential applications of HiP-CT through quantification and morphometry of glomeruli in an intact human kidney, and identification of regional changes to the tissue architecture in the lung of a deceased COVID-19 donor. of cellular structures in human embryonic development 4, 5 and mouse models of cancer metastasis 6 and drug uptake 7 . Optical clearing of whole adult human organs has recently been achieved; however, it requires several months for intact organs, causes changes in tissue morphology, and light-sheet microscopes cannot presently image whole organs in their intact state 8 . High resolution magnetic resonance imaging (MRI) requires minimal tissue preparation, does not cause tissue distortion and achieves 100 μm voxels in an ex vivo human brain 9 . However, this type of MRI scan requires 100 hours for the human brain and does not achieve the resolution required to capture cellular detail. Multi-beam electron microscopy can provide images of human tissue from cellular to sub-cellular scales 2 , but cannot capture the large tissue volumes required for whole human organs. Synchrotron X-ray tomography (sCT) is a promising approach to image whole human organs at cellular detail 10, 11 . X-rays are intrinsically suited to imaging different length scales due to their high penetration and short wavelength. Some specialised synchrotron tomography instruments have achieved high resolution relative to the overall size of the biological sample: including resolving cellular features in ⌀ 32 mm human spinal cord biopsies 12 , achieving ~5 μm resolution in human lung biopsies (⌀6 mm) 13 , and 87 nm resolution in volumes of interest (VOIs) within a ~⌀1 mm intact drosophila leg 14 . In these cases, the entire sample was scanned at the reported resolutions rather than a hierarchical series of resolutions performed with a single instrument. Local tomography or zoom tomography is an established synchrotron technique that enables this hierarchical approach. Whilst it has been developed for use in small (500 μm) biological tissue samples, contrast agents such as barium or osmium are often used 1, 15, 16 . For large objects, where staining is far more challenging, local tomography has been confined to objects with high density differences, such as those found in bones or fossilised remains [17] [18] [19] . There are no established sCT techniques that achieve cellular resolution far from the central axis of rotation in large soft tissues such as human organs. Phase-contrast based sCT 18, 20, 21 , specifically, propagation-based imaging 22 , can theoretically be applied to image large, soft tissues. However, this requires a high energy X-ray beam to penetrate large samples, coupled with the high coherence and flux required to resolve cellular detail (and a large enough beam size to scan whole organs in reasonable timeframes), which was previously not available in any laboratory source or at a single synchrotron beamline worldwide. HiP-CT requires specific sample preparation, scanning and reconstruction approaches shown in Figure 1A (see Online Methods for detailed steps). Briefly, organs are fixed, partially dehydrated and physically stabilised for scanning ( Figure 1C ). HiP-CT scans are then performed hierarchically, the first typically at 25 μm/voxel over the whole organ followed by VOIs at 6.5 μm/voxel and 1.3-2.5 μm/voxel. Scanning time for HiP-CT is faster than other techniques 8, 9 , currently ~16 hrs for a whole brain at 25 μm/voxel and ~3.5 hrs for a whole kidney at 25 μm/voxel (see Online Methods and Extended Data 1) for further details). Our experimental setup is largely automated and can be adjusted to increase scanning speed for smaller organs whilst accommodating different fields of view for higher resolution imaging. Our scanning procedure allows users to select high-resolution VOIs with the spatial context provided by the preceding lower resolution scans (see Supplementary Information) . Long term physical stabilisation of the organs was necessary for HiP-CT, both to enable multi-resolution registration and to allow organs to be removed from the beamline whilst higher resolution VOIs were selected. Our optimised organ stabilisation method (see Online Methods for further details) using agar-agar gels was highly effective for maintaining organs positions (see Supplementary Video 1 where the higher resolution scans were taken several months after the lower resolution scans and simply registered by manual rigid transformation) and uses easily obtained materials. Several other key procedures and modifications of the BM05 experimental hutch, summarised and prioritised in Table 1 and outlined in Online Methods, describe the essential developments for HiP-CT. Central to HiP-CT is the increased spatial coherence provided by the EBS. This spatial coherence allows propagation distances approaching the near field limit for the highest resolution scans and thus resolves the faint density contrasts in soft tissue 1 . Much of the HiP-CT scanning geometry aims to reduce X-ray dose to the sample, optimise the detector dynamic range, reduce ring or bubble artefacts and supress beam hardening. Matching the horizontal gaussian profile of the beam to the attenuation profile of the sample at 25 μm/voxel, achieves all the above benefits (see Online Methods for details). The dose limit is crucial in HiP-CT, as once it is surpassed bubbling is induced in the sample causing tissue damage and introducing artefacts (see Supplementary Information for further details). To perform the extreme off axis local tomography reconstructions, we have developed the use of hierarchical reference scans. For every higher resolution VOI a reference scan is taken in an identical agar-ethanol filled jar mounted on top of the sample jar (see Figure 1C ). This scan provides a background estimate that can be removed when performing reconstruction, thus eliminating much of the low frequency sinusoidal background variations. To demonstrate the effectiveness of the reference scan method, we performed a series of high-resolution scans transecting the kidney from the centre of rotation to the outer edge ( Figure 1Bi ). The consistent image quality across the high-resolution scans (Figure 1Bii ) can be appreciated in the zoomed insets and no correlation between signal-to-noise ratio (SNR) and lateral scan position (Pearson's correlation coefficient -0.25 p = 0.21, see Extended Data 2). The HiP-CT scanning procedure adapts two protocols originally developed to image large fossils. The first, the attenuation protocol, normalizes the absorption in the field of view 24, 25 whereas the second, the accumulation protocol, provides extended dynamic range 26 . At 25 mm/voxel, HiP-CT scans are dominated by attenuation, hence there is reduced contrast sensitivity and a requirement for more accumulations, whereas higher resolutions are phase dominated leading to fewer accumulations (see Table 2 , and Supplementary Data 1 for all scanning parameters). The dominance of attenuation at lower resolution creates horizontal line artefacts during concatenation of the radiographs, due to the vertical profile of the beam. To remove these artefacts the vertical profile residual background after flatfield correction is subtracted before reconstruction. For higher resolution scans where phase effects dominate, this step is not required (see Online Methods for details). After pre-processing of radiographs to generate high-quality local tomography (see Online Methods for further details), image reconstruction can be performed using a filtered backprojection algorithm, coupled with a single-distance-phase-retrieval 27 , combined with a 2D unsharp mask performed on the projection phase maps, as implemented in the software PyHST2 28 . All the sub-scans (covering typically 2.5 mm vertically) are concatenated after reconstruction. Subsequently, residual ring artefacts that would not have been removed in the preceding steps are corrected on reconstructed slices 29 . To assess the performance of HiP-CT for imaging human organs, we scanned the intact human lung of a 94-year-old female (Donor 1 -clinical details in Online Methods) beginning with the whole organ at 25 μm/voxel, before selecting VOIs for zoomed imaging at 6.5 μm/voxels and 2.5 μm/voxels (green and blue columns of Figure 1Di ). We estimated the resolution of HiP-CT via Fourier shell correlation analysis (FSC) 1,16 . Resolution was estimated at the 1/2 bit criterion to be 10.4±0.17 μm for 2.5 μm/voxel images, 18.3±0.6 μm for 6.5 μm/voxel and 72±3.4 μm for 25 μm/voxel images (see Extended Data 3). To assess the consistency in the quality of higher resolution scans at different tissue depths and distances from the rotational centre of the intact organ, we analysed intensity distributions across two high resolution VOIs. We found the image intensity histograms had an intersection of 71±3 %. Both distributions showed positive skewing and kurtosis with minimal differences in mean intensities between the different VOIs and (Figure 1Dii ). In addition, we quantified image quality differences between the two volumes using the structural similarity index (SSI) 30 (Figure 1Diii ). No significant difference in SSI (median values; 0.839-0.841, p = 0.88) was observed across compared image volumes, indicating that HiP-CT can achieve high resolution scanning in any region of the intact human lung with consistent quality. The large size of adult human organs is a fundamental imaging challenge: the penetration depth of the imaging photons (X-ray for HiP-CT) and diffusion of reagents (ethanol for HiP-CT) may both be limiting factors. Accordingly, image quality tends to decrease from small to large specimens. We therefore qualitatively compared high zoom HiP-CT scans of intact human lung and a physically subsampled biopsy (cylindrical biopsy ⌀8.1 mm height 14 mm). The image quality of the two samples was found to be indistinguishable ( Figure 1E ). The fine structure of the lung tissue including the capillaries and alveoli are depicted in a histopathologically correct and non-distorted manner with very thin membranes within the alveolae (yellow arrows) being some of the smallest structures (~5 μm thickness) evident in both samples. Thus HiP-CT is versatile, providing high quality imaging of human lungs across multiple length scales, independent of the region sampled or the size of the tissue imaged. Next, we sought to apply HiP-CT to image multiple length scales in a variety of human organs. Intact lung, heart, kidney and spleen (Donor 1) and brain (Donor 2), were acquired from two donors (clinical details in Online Methods), processed and imaged by HiP-CT. Images were sequentially acquired at 25 μm/voxel to capture the entirety of each organ, before 6 μm/voxel and 2.5 or 1. Human organ function is driven by the collective activity of organotypic functional units. Each functional unit comprises multiple spatially arranged cell-types that facilitate specialised functions. We used high-resolution HiP-CT to image functional units across the same five human organs ( Figure 2 ). The hierarchical nature of HiP-CT, isotropy of the image data and high resolution facilitate the identification of specific organotypic structures and in certain cases specialised cells. The use of comparative and correlative histology is a further aid for distinguishing specific structures and cell types (see Supplementary Video 4). In the brain, the layers of the cerebellum are visible (Figure 2Aiii , 2Aiv) and a number of individual Purkinje cells are evident between the molecular and granule cell layers, identifiable by their distinctive pyramidal cell body and anatomical location 31 . Collectively, these images show that HiP-CT is capable of imaging intact human organs down to the resolution of organotypic functional units and certain types of specialised cells. Next, we sought to assess the utility of HiP-CT to obtain physiologically relevant structural information using the human kidney as an example. The functional capacity of the human kidney arises from the collective activity of individual units called nephrons. Each nephron has a glomerulus: a network of blood capillaries which is the site of blood filtration. The total number of glomeruli (N glom ) is indicative of the kidney's capacity for filtration, and as nephrons are not (re-) generated through the life of an individual 33 , reduction in N glom is a feature of physiological ageing and chronic kidney disease 34-36 . We assessed N glom in a 94-year-old female (clinical information in Online Methods -Donor 1) with HiP-CT (Supplementary Video 3 and Figure 3Ai ). At 25 μm/voxel, the parenchymal volume was segmented (Figure 3Aii ), at 6 μm/voxel, the number of glomeruli within a representative volume were counted ( Figure 3Aiii ). N glom was calculated as 310,000 for this individual, which is within the range of previous studies using either stereological analysis 34, 36 , contrast-enhanced MRI 37 or CT 35 and specifically accords well with measures of N glom in older individuals 36, 38 . Using 1.3 μm/voxel scans we also assessed glomerular volume, an important structural determinant of overall kidney health which has been shown to increase in individuals with reduced nephron number, obesity and hypertension 34, 36 . Thirteen glomeruli were manually segmented to calculate V glom (Figure 3Aiv ) resulting in a value of 5.05 ± 0.09 × 10 -3 mm 3 , similar to the range of V glom (3-5 × 10 -3 mm 3 ) estimated by stereological and MRI analysis 36, 37 . Additionally, the isotropy of HiP-CT enabled the calculation of mean glomerular surface area (1.7 ± 0.4 × 10 5 μm 2 ) and sphericity (0.58 ± 0.09), both of which cannot be assessed using conventional modalities 38 . Moreover, we matched microscopy of histological sections to the same regions of the kidney imaged with HiP-CT, finding an equivalence of structural detail in the two modalities ( Figure 3B ). Histological results validate the accuracy of glomeruli segmentation and show that sample preparation and high X-ray dose expose during HiP-CT do not cause evident morphological tissue damage (see Extended Data 5) . Therefore, HiP-CT has the potential to quantify functional units and their 3D morphology with histological resolution within intact human kidneys, providing morphometric insights across entire organs. We finally sought to apply HiP-CT to a contemporary biomedical problem by examining the structural changes in the lungs of a patient diagnosed with COVID-19, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The major cause of morbidity and mortality in COVID-19 is severe acute respiratory distress syndrome (ARDS) 39 . The clinical course of COVID-19 is well described 40 and established histological features of SARS-CoV-2-infected lungs include alveolar inflammation, fibrosis and necrosis 41 . Recently, these findings were built upon by sCT and 3D reconstruction of millimetrethick samples from COVID-19 lungs, demonstrating hyaline fibrotic deposits, lymphocytic infiltrates and vasculature occluded by thrombi 42 . To assess the utility of HiP-CT to detect lung changes in SARS-CoV-2-infected lungs, we imaged an intact upper right lung lobe acquired from the autopsy of a 54-year-old male patient who died from COVID-19-related ARDS ( Figure 4A ). The clinical features of this patient are described in the Online Methods. Orthogonal 2D slices through the volume of the lung imaged at 25 μm/voxel demonstrated high intensity regions in the lung periphery (see Figure 4Aii and Supplementary Video 5) consistent with patchy lung consolidation described by conventional clinical radiology in COVID-19 43 . Upon higher resolution scanning of VOIs at 6 μm/voxel, 2D slices depicted heterogeneity in the loss of normal alveolar architecture, with particular secondary pulmonary lobules displaying greater parenchymal deterioration than others (Figure 4Aiii ). Higher magnification of the more affected secondary pulmonary lobule at 2 μm/voxel ( Figure 4Avi ) demonstrated cavitation of lung parenchyma, alveolar obstruction, (likely from thrombi based on their similar contrast to intravascular blood), thickening of septi between adjacent alveoli and blood capillary occlusion with adjacent cellular infiltrates (likely aggregations of lymphocytes 41 ) (Supplementary Video 5). These results indicate that HiP-CT is capable of reproducing the microstructural findings observed in COVID-19 lung biopsies 41,42 across large tissue volumes, and in providing access to structures at novel length scales e.g. the secondary pulmonary lobule ( Figure 4B ). Given the heterogeneity of parenchymal damage, we aimed to characterise changes of lung architecture in differing regions of the lobe with varying levels of parenchymal deterioration. We identified and segmented two adjacent secondary pulmonary lobules from the periphery of the COVID-19 sample ( Figure 4B ) which showed differing parenchymal deterioration termed COVIDS (less deteriorated) and COVID C (more deteriorated). For the COVIDS lobule (yellow), we used the higher resolution 6 μm images to segment an acinus ( Figure 4Cii ) and compared this to an acinus segmented from the control lung ( Figure 4Ci ). These images show the loss of overall surface area in the lung and smaller and less uniformly shaped alveoli. To quantify this difference, we segmented the free air space using 2.5 μm/voxel scans in VOIs from COVID C and COVID S regions and compared these to an uninfected control lung (n=6 VOIs per group) ( Figure 4Bi ). 3D quantitative analysis was performed to assess microstructural changes, revealing a significant decrease in surface area to volume ratio ( Figure 4Dvii ) and increase in septal thickness ( Figure 4Dviii ) between control vs COVID S , COVID S vs COVID C and control vs COVID C (p<0.001). Airspace connectivity is significantly higher for COVID C than control (p=0.03) and significantly higher than COVID S (p<0.001). These data (Figure 4Di -4Diii) and the distribution of airway diameters (Figure 4Dix ), collectively quantify the heterogeneity of lung deterioration in SARS-CoV-2 infection. Thickening of alveoli septae leads to decreased airspace connectivity and a decrease in the modal airway diameter. In consolidated areas, infiltration of loose connective tissue and fluid into the alveoli leaves only tiny unconnected portions of the alveoli and the large well connected alveoli ducts ventilated. This is evident in the bimodal distribution of airway sizes and high airspace connectivity. Thus, HiP-CT detected regional changes in the architecture and morphology of the COVID-19 lung and allowed quantification, which can inform our understanding of the pathogenesis of COVID-19-related ARDS in SARS-CoV-2 infection. Here, we developed HiP-CT, a novel phase-contrast based sCT modality utilising the first high-energy 4 th generation synchrotron source 23 . Through our various methodological developments, we have enabled hierarchical 3D imaging of multiple intact human organs, providing consistently high imaging quality from whole human organs down to individual organotypic functional units and certain specialised cells at any location within the organ. Due to the mild sample preparation and non-destructive imaging, HiP-CT samples can be subsequently compared with other imaging techniques e.g. histology, to provide validation and aid in HiP-CT image labelling. Our technique has several key advantages over previous sCT based methods 1 : i) different resolution images from any location can be easily aligned with one another, facilitating data visualisation and interpretation; ii) whether a high resolution region is representative of the whole organ can be easily assessed; iii) data collection and storage are efficient, particularly for rare and or spatially distant features. Our exemplar of multiscale glomerular analysis demonstrates the benefit of hierarchical imaging with representative subsampling to estimate number and morphology of spatially disparate (glomeruli) organotypic features. We also leveraged the advantages of HiP-CT for multiscale and quantitative 3D analyses in pathological contexts, identifying and quantifying regional changes to the architecture of the air tissue interface and alveolar morphology in the lung of a donor with confirmed pulmonary COVID-19 disease. Mapping the hierarchical structure of human organs is a major challenge in biology. International consortia to map the human body include the Human Cell Atlas and the Human BioMolecular Atlas Program 44, 45 . Such consortia have generated data of the transcriptional states and cellular and molecular composition of human tissues 46 . To integrate HiP-CT into such efforts, a future challenge will be the validation and extension of automated cell detection and labelling. This may necessitate the development of contrast agents 47 or of multi-modal imaging using techniques with established targeted labelling 3 . Another challenge is the computational power and storage required to handle the magnitude of data generated by HiP-CT. Whilst the hierarchical nature of HiP-CT is inherently data efficient, a single VOI through the depth of the lung captured at 6 μm/voxel still amasses ~600GB of data. Emerging cloud-based frameworks 48 could improve the speed of image processing and analysis and facilitate the open accessibility of HiP-CT, providing a means to complement global efforts to map the human body. HiP-CT has considerable translational potential for biomedical applications, which we demonstrated by 3D imaging a SARS-CoV-2-infected lung. In addition to reproducing the histopathological hallmarks of COVID-19, HiP-CT revealed extensive regional heterogeneity in parenchymal damage. Our HiP-CT approach clearly demonstrates how physical sub-sampling methods which aim to infer organ-wide pathophysiology could be confounded by such heterogeneity. This potential confounder is surmounted by HiP-CT due to its flexibility in the scale of tissue volume that can be imaged, independent of location and over a wide range of resolutions. Moreover, quantitative analysis of lung architecture from HiP-CT images align with clinicopathological observations of an increased volume of ventilated air that does not participate in gas exchange in COVID-19-related ARDS 39, 41 . Further HiP-CT investigation of COVID-19-related ARDS requires refinement using image analysis methodologies such as machine learning 49 . HiP-CT could also be used to provide insights into the secondary consequences of COVID-19 in other organs, such as the kidney and brain; both showing evidence of tropism for SARS-CoV-2 50 . HiP-CT will evolve alongside advances in synchrotron technology. Here, we present the first results using our experimental method developed on a test beamline (BM05). The completion of a new beamline at the ESRF, BM18, in 2022 is anticipated to provide increased resolution, in volumes several times larger than human organs whilst using lower X-ray doses, with improved sensitivity and a much higher speed. Such 4 th generation synchrotron sources may herald new possibilities in the life sciences. Control organs were obtained from two bodies donated to the Laboratoire d'Anatomie des Alpes Françaises (LADAF). Dissections were performed respecting current French legislation for body donation. Body donation was based on free consent by the donors antemortem. All dissections respected the memory of the deceased. The post-mortem study was conducted according to QUACS (Quality Appraisal for Cadaveric Studies) scale recommendations 51 Donor 1, from which the heart, lung, kidney, and spleen were imaged, was a 94-year-old, 45 kg, 140 cm female with right sylvian and right cerebellar stroke, cognitive disorders of vascular origin, depressive syndrome, atrial fibrillation and hypertensive heart disease, micro-crystalline arthritis (gout), right lung pneumopathy (3 years before death), cataract of the left eye, squamous cell carcinoma of the skin (left temporal region). Donor 2, from which the brain was imaged, was a 69-year-old, 40 kg, 145 cm female, with type 2 diabetes, pelvic radiation to treat cancer of the uterus, right colectomy (benign lesion on histopathology), bilateral nephrostomy for acute obstructive renal failure, cystectomy, omentectomy and peritoneal carcinoma with occlusive syndrome. Donor 3, from which the entire upper left lung lobe and a core biopsy from the periphery of the right upper lobe were obtained was a 54-year-old male patient who died from COVID-19, 21 days after hospitalisation. Treatment involved mechanical ventilation. Regarding comorbidities, arterial hypertension and type II diabetes were not diagnosed prior to death. Donor 4, from which a biopsy from the right lung, lower lobe was taken was a male of 77 years. Resection of the lung segment was due to small pulmonary adenocarcinoma (1.4 cm), coronary heart disease, arterial hypertension, chronic rheumatic disease (polymyalgia rheumatica). Bodies were embalmed with formalin solution as follows: embalming solutions -4500 ml of formalin diluted to 1.15% in a solution containing lanolin and 4500 ml of formalin diluted to 1.44% were injected sequentially into the right carotid artery after death. Bodies were then stored at 3.6 °C. All eviscerations were performed in the LADAF, between April and July 2020. During evisceration, vessels were exposed, and surrounding fat and connective tissue removed. Organs were post-fixed in 4% neutral-buffered formaldehyde at room temperature for one week. The lungs were inflated with the 4% formalin solution using a large syringe to inject the solution in the bronchia until a correct shape of the lungs was obtained. All COVID-19 autopsies were carried out according to standard procedures by the Deutsche Gesellschaft für Pathologie and followed regulatory requirements. Autopsies were performed in a room with adequate airflow (>6 air changes per hour of total room volume) using appropriate personal protective equipment (i.e., hazmat suits, boots, goggles, FFP2/3 masks). Organs were eviscerated and immediately fixed in 4% neutral-buffered formaldehyde. Lungs were immediately inflated and fixed by tracheal instillation with 4% neutral-buffered formaldehyde, the trachea was then clamped, and specimens were left for post-fixation in 4% neutral-buffered formaldehyde at room temperature for ≥72 hours before further dissection. Samples were partially dehydrated to 70% ethanol (through four successive concentrations see below) prior to transportation to ESRF. COVID-19 lung samples were transported to ESRF, Grenoble at ambient temperature in double-sealed containers. To ensure resistance of the samples to the X-ray dose, avoid health risks associated with formalin; all organs were equilibrated in a 70% ethanol solution. In addition, ethanol replaces water in tissues, thus the density of the water-rich tissues and water-filled cavities decreases, while the density of other tissues remains closer to the original one. This improves X-ray contrast. To avoid organ shrinkage, serial dehydration was performed through: 50%, 60%, 75%, and finally, 70%. Each solution was 4x volume of the organ. The time at each concentration is dependent on organ size and tissue composition (adipose tissues requires longer). In all cases adequate dehydration can be assessed by tapping the organ container and looking for streaks in the solution. The slowest organ to prepare is the brain owing to its size and high adipose content. In our case, brain was dehydrated over 3 weeks, however optimisation of this step has not been performed and it is likely that this can be done more quickly if required 8 . Degassing was performed at each dehydration step with the organ immersed in the respective solution using a diaphragm vacuum pump (Vacuubrand, MV2, 1.9m 3 /h), to remove both free and dissolved tissue gas. Degassing cycles were performed with increasing duration from 2 minutes to 40 minutes (total time typically 2h). At each cycle, pumping was stopped when bubbling decreased in intensity, or became intense enough to potentially cause organ damage. For Donor 1 lung, after each cycle, the degassed ethanol solution was gently forced into the main conducting air ways with a large syringe in order to keep the morphology of the lung in its original inflated state. The final degassing step, was longer (typically 3-4 hours), performed until no bubbling was observed. Samples were then mounted. It should be noted that some damage attributed to degassing was observed in the brain of Donor 2 and the protocol was amended to use a series of thermal cycles. The brain is immersed in a bath of pre-degassed appropriate concentration Ethanol, this is stored at 4°C for 5 days to equilibrate. 5 cycles with successively increasing ethanol concentration are used (50%, 60%, 70%, 70%, 70%). This protocol requires vacuum degassing only for the final mounting of the organ, however it requires ~5 weeks. It may be possible decrease the time by combining gentle vacuum degassing, with thermal cycling. Organ mounting requires delicacy, as any remaining gas bubbles, density inhomogeneities or insufficient sample stabilization dramatically reduces scan quality. The 70% ethanol-based mounting medium was prepared using demineralized water (20 g/L of agar). Once gelled, the block was cut into small cubes of 1 cm 3 that were immersed in ethanol at 96%, the volume ratio ensuring an equilibrium conc. of 70% of ethanol (2.96 L of ethanol at 96% for 1 L of gel) for ~24 hrs. Equilibrium was assessed by the gel cubes sinking (over several dozen seconds) to the bottom of the container after agitation. Once equilibrated, the gel cubes still immersed in the solution were degassed for two cycles of approximately one hour each, until no bubbles formed. A third of the cubes were stored in the in this degassed equilibrated state, the remainder were blended or more recently crushed into "blended gel", the consistency of which was adjusted by adding 70% ethanol, or removing the ethanol by pressing with a filter. During the exploratory phase of this project, several mounting protocols were tested. The first method, used for the COVID-19 lung-lobe consisted of using only the agarose gel cubes. This preparation allowed efficient final degassing but caused unwanted local compression of the soft organs (visible in Supplementary Video 5). The final protocol developed, filled the bottom of the cylindrical container with gel cubes in a few centimetres of blended gel, to ensure the organ does not contact the container base and preventing rotation of the sample. The container was then half-filled with blended/crushed gel, and the organ carefully immersed and set in the desired position (with care to avoid bubbles). The organ was covered completely with blended/crushed gel. The whole container was then degassed, with care to ensure that the gel did not inflate too much due to trapped gas bubbles. Once degassed for 1h (or few minutes for brains), the mounted organ was covered with gel cubes to ensure solid fixation. The whole mounting was degassed a final time for few minutes, then the container was sealed for scanning. We used specially designed sample holders for the scanning process. They were designed to ensure safety in case of a leak of the ethanol via a double sealing, to be mechanically stable and resistant to high X-ray dose. Two samples can be mounted one over the other for longer scan automation. Alternatively, only one organ can be installed, and the equivalent organ container filled with 70% ethanol solution is installed in the second place for beam reference measurements in case of local tomography scans ( Figure 1C ). The ESRF-EBS provides a coherence length of 8 μm at 70 keV on BM05. The polychromatic beam provides a high flux whilst enabling a longer propagation distance before holographic imaging mode is reached. Both these features allow longer propagation distances before reaching the geometric blurring limit due to the angular source size up to the near-field limit, or a bit beyond. On BM05 the propagation distance is physically limited to 3.5 m. For both 6.5 and 25 μm/voxel scans, this restriction prevents us reaching the theoretically estimated maximum propagation distance limit at 70 keV (respectively 6 m and 23 m) defined by the minimum between the geometric blurring of 1 pixel and the near-field limit, whilst for 2.5 μm/voxel and lower, the propagation distance limit is 1.3 m (estimated to be close to the near field limit). The beam flux and energy must be tuned for each magnification and sample to ensure the average energy is sufficient to penetrate through the sample but low enough to allow fast scans. Tuning is achieved with a combination molybdenum and copper filters (energy tuning) and fused silica bar attenuators (flux and beam profile tuning). To preserve the beam coherence the filters and optics are made of high-quality mirror polished materials to ensure material homogeneity. Similarly the X-ray optics are made of pf6/If1 beryllium which can be highly polished. The scintillators must be as dense as possible whilst not degrading the resolution. LuAG:Ce provide the necessary stopping power with a high light output and the transparency required for high resolution phase contrast. The scintillators thickness was optimised to provide a compromise between light output and maximum optical resolution for each X-ray optic. All scans were taken using one of two detector optics: the d-zoom (for 25-6.5 μm/voxel scans) and the zoom optic for 6-1.3 μm/voxel scans. Both optics were mounted with PCO edge 4.2 CLHS cameras. In designing the optics we aimed to have the highest possible numerical aperture without having to reduce thickness of the scintillator and hence reduce resolution. The greatest limitation for the detector optics, particularly the zoom optic, is darkening due to the polychromatic beam. To prevent darkening the optic is either Europe PMC Funders Author Manuscripts intrinsically X-ray hardened (as is the case for the d-zoom optic) or is protected from darkening through the use of thin glassy carbon mirror to reduce internal scattering, and lead glass in the front of the optic to stop as much scattering as possible. A beam stop was also used to prevent beam back scatter. Finally, we developed a rapid curing process using blue LEDs to recover optics in 12 hrs in the case that optics did darken. 2048x2048 pixel scientific Complementary Metal Oxide Semiconductor (sCMOS) detectors were chosen for HiP-CT to avoid data loss during read out time and benefit from their 74% quantum efficiency at the peak emission of the LuAG:Ce. The lower full well capacity of the sCMOS by comparison to CCD detectors is efficiently mitigated through our accumulation scanning protocol. One organ in its sealed container was installed in the bottom holder, and the equivalent container filled with 70% ethanol gel was installed in the upper holder ( Figure 1C ). This second container was used for acquisition of beam references. Partial angular integration of scans from the reference jar every 100 projections provided a new reference for flat field correction of the radiographs. In this way, most of the low frequency effects of local tomography were directly corrected, leading to normalized intensities of the projections even in case of off-center local tomography scans (see Figure 1B ). This approach also improves the dynamic range of the detector by avoiding direct exposure to the beam-the sample and its mounting media act as filters. This protocol, we term the "attenuation protocol", is derived from an approach that was originally developed to scan highly absorbing fossils, first in monochromatic beam 24 , and later in polychromatic beam 25 . In this protocol, the dynamic level was maximised for scanning organs at 25 μm/voxel, by putting the sample slightly off axis to benefit from the natural horizontal gaussian profile of the beam. This approach, reduces the flux on the border of the sample (where the absorption is lower), and provides maximum flux to the thickest portion of the sample. As mentioned above, in addition to correction of the local tomography effect, our scanning protocol avoids direct exposure of the detector to the beam, allowing the saturation level of the detector to be adapted to the less absorbing part of the sample instead of to the direct beam intensity. As the general absorption contrast is dominated by the cylindrical shape and the organs are close in density to the ethanol solution, this approach also efficiently removes any beam hardening effect, or differential phase contrast effect in case of off-axis scans. Finally, in order to ensure a high dynamic level, the detector is used in accumulation 26 , with typically 10 and 5 sub-frames for the 25 μm/voxel and 6.5 μm/voxel scans respectively. The 2.5 μm/voxel and 1.3 μm/voxel scans are done without accumulation to limit the X-ray dose and because their contrast is dominated by phase-contrast. As phase-contrast is typically 1000 times more sensitive than absorption, it is possible to use lower dynamic level on the detector, and thus reduce the X-ray dose. The benefit of each aspect of this scanning protocol is demonstrated in Extended Data 6 Two acquisition modes were used depending on the size of the organ samples -half and quarter acquisitions. Most scans were performed in half-acquisition mode with the centre of rotation on the right side of the field of view (moved by typically 900 pixels) to obtain a field of view of 3800 pixels with 6000 projections. For the largest organs, the complete scans at 25 μm/voxel were performed using a quarter acquisition protocol based on two scans (one half-acquisition + one annular scan) of 9990 projections each. Concatenation of the quarter acquisition was performed by calibrating the overlapping scan region with a gradual transition and a normalisation of the grey levels in the common area of the two scans. Once concatenated, the reconstructed field of view is 6000 pixels. To cover complete organs or to scan large columns in local tomography, an automated z-axis series was performed. The typical sampling step was 2.2 mm vertically for a corresponding beam size of 2.6 mm corresponding to an overlap of 18% (some initial organ scans used larger steps (up to 3.6 mm), and larger overlap -upto 50%). All scanning parameters are presented in Table 2 and Supplementary Data 1. Based on the scan times possible (Extended Data 1) the brain supplied by Donor 2 can be scanned at full 25 μm resolution in ~16 hrs (16 cm) ; and the smallest diameter organ -the kidney (7 cm) in ~3.5 hrs. Prior to reconstruction 25 μm/voxel radiographs were vertically concatenated and the remaining vertical profile of the beam (regular horizontal lines) subtracted (at 6 μm/voxel and lower this step is unnecessary as the scans are not attenuation dominated). For higher resolution scans we first performed tomographic reconstruction, then cross correlation between slices to ensure alignment. For overlapping slices we use a ponderate average to create a gradual transition from one slice to the next. This removed horizontal artefacts in these phase-dominated scans. After pre-processing, tomographic reconstruction was performed using the filtered back-projection algorithm, coupled with a single distance phase retrieval 27 , and a 2D unsharp mask on the projections, as implemented in the ESRF inhouse software PyHST2 28 . All sub-volumes were converted into 16 bits, and vertically concatenated. The remaining ring artefacts were corrected on the reconstructed slices using an inhouse Matlab system derived from Lyckegaard et al. 29 . In some cases, a final correction of the horizontal stripes was performed on the reconstructed volumes after vertical reslicing. After HiP-CT scanning the kidney from Donor 1 was removed from the mounting jar section and stained for histological validation (N=1). The coronal location of the kidney aligned with a HiP-CT high resolution image column was manually identified and the kidney dissected. Large coronal sections were placed into cassettes to follow the standard tissue treatment procedure: dehydration through a series of graded ethanol baths, paraffin embedding and microtome sectioning of paraffin blocks. Slides were routinely stained with haematoxylin and eosin (H&E). Slides were visually inspected to identify precisely aligned images to high resolution HiP-CT. In addition to performing H&E staining on the HiP-CT imaged kidney in the portions of the sample exposed to the highest X-ray dose ( Figure 3B and Extended Data 5), staining was also performed on the COVID-19 lung biopsy sample (N=1) shown in Figure 1E and on healthy control (Donor 4) lung biopsies. (Extended Data 7) shows H&E staining as well as anti-CD31, anti-thyroid transcription factor 1 (TTF-1) and anti-fibrin immunohistochemical staining on the lung biopsy samples. As these lung samples were biopsies, they did not receive the high radiation doses the kidney was subjected to (see Supplementary information for discussion and estimation of dose exposure), however these sample underwent similar preparation and were exposed to the ESRF-EBS on BM05. The final volume renderings were performed using different 3D software packages, notably VGStudioMax 3.2.4 (Volume Graphics, Heidelberg, Germany), Amira v2019.6 and Dragonfly 2020.2.0, For all analysis ImageJ version 2.1.0/1.53c Java 1.8.0_66 was used. FSC was performed on the Donor 1 Lung sample. Two independent scans taken sequentially (after 0.1 mm of vertical displacement of the sample and of the center of rotation) and using the full number of projections for both were fully reconstructed as per the normal HiP-CT procedure with the complete chain of pre-and post-processing. The pairs of volumes were loaded in VGStudioMax 3.2.4 and precisely aligned. The common part was then cropped and exported in the same 16 bits tif format, resulting into two volumes of same size and same location, but with fully independent acquisition and reconstruction. 9 randomly selected subvolumes of data at sizes ranging from 200 -1000 voxels were taken from both aligned volumes and the FSC computed for each. The ½ bit threshold intersection with the FSC curve was used to estimate the resolution corresponding to each voxel size. The mean and standard deviation of the intercepts is provided and the FSC curves are provided in Extended Data 3. SNR ratio was evaluated from the mean (μ) and standard deviation (σ) of pixel values in manually drawn ROIs of features (ft) and background (bg) areas. The SNR was calculated as (μ ft -μ bg )/σ bg . In the kidney the tubule walls were used as the features with the lumen of the same tubule used as the background region. N=3 tubules per lateral resolution image were analysed. Image quality comparison was performed using the structural similarity index 30 implemented in Matlab 2020b (ssim function). Equally sized subvolumes from the two columns were used in their original 32-bit form (999 slices in each case). Histograms of the two subvolumes were calculated with fixed bin width of 0.001. Skew, kurtosis and mean pixel intensity were calculated via Pyradiomics v3.0. 52 . Structural similarity index was calculated between pairs of xy slices from the two subvolumes. Two images were randomly selected (by slice number); either both images were from the same subvolume (1-1) and (2-2) or the images were from different subvolumes (1-2) and (2-1). N=200 pairs of images were analysed for each group. One-way ANOVA of the output was performed in Matlab 2020b using the anova1 function. Using the 25 μm/voxel scans of the whole kidney, the parenchyma of N=1 kidney was semiautomatically segmented in Amirav2019.6. After manually aligning all three resolution datasets, two cylinders, one through each of the 6 μm/voxel and 1.3 μm/voxel columns, were defined perpendicular to the kidney surface. The cylinders had radii, lengths, and volumes of (1300 μm, 40,811 μm and 2.17x10 11 μm 3 ) and (203 μm, 9814 μm and 1.3×10 9 μm 3 ) for the 6 μm/voxel and 1.3 μm/voxel datasets respectively. These cylinders were considered as virtual biopsies. In the 6 μm/voxel case any glomeruli that fell within the cylinder were counted (blue dots in Figure 3Aiii ). For the total number of glomeruli, the volume of parenchyma in the 6 μm/voxel virtual biopsy was found via semi-manual segmentation in Dragonfly 2020.2.0. The number of glomeruli counted in the 6 μm/voxel virtual biopsy was divided by the volume of parenchyma in the 6 μm/voxel virtual biopsy and multiplied by the total volume of the parenchyma. In the 1.3 μm/voxel dataset any glomeruli that touched the cylinder were manually segmented in Amira v2019.6 in 3D. The volume, surface area and sphericity were calculated using the binary mask from these segmentations in ImageJ using the MorphoLibJ plugin-(analyse regions 3D) 53, 54 . Alignment of the HiP-CT and H&E histology sections was performed in VGstudioMax 3.2.4. Pseudo coloring of the HiP-CT was performed by applying a 100 pixel median filter on the histological slice and superimposing these colors to the original grey level slice of the HiP-CT. Grey-level version of the histological slice was obtained by desaturating the picture, inverting its contrast, and adjusting linearly the contrast to reach 0.2% of saturation in black and white on an 8 bit scale. Manual segmentation of secondary pulmonary lobules was performed in Amira 2019.6 using the 25 μm/voxel COVID-19 upper right lung lobe scans. The data was binned to 50 μm/voxel prior to segmentation to reduce computational load. Acini segmentation was performed using column of 6 μm/voxel data in the control lung and a region of the COVID-19 lung selected by pulmonary radiologist as relatively spared. Regions of the image that contained a clear terminal bronchiole were cropped and segmentation was performed semi-manually: first tissue air boundaries were enhanced using an unsharp mask and a Canny edge filter in ImageJ 53 , enhanced images were then transferred to Aimia2019.6 and a 3D magic wand tool was used segment the 3D airspace. For microstructural analysis, N = 6 250×250×250 pxl subvolumes from the 2.2 μm/voxel datasets of the COVID-19 and control lung, were chosen, (randomly in the case of the control lung, and in the COVID-19 case, randomly within larger areas designated by pulmonary histopathologists as structurally preserved or consolidated i.e. from areas where alveoli morphology was identifiable versus areas where there was widespread consolidation of the parenchyma). Binary images separating airspace from alveolar septae and microvessels were produced in ImageJ by thresholding the images using one of the two following methods: 'triangle' method for Control and COVID S and 'Yen' method for COVID C 53 . A 3D Chamfer distance from the MorpholibJ plugin 54 was used (using Svensson 3, 4, 5, 7) to create the distance maps (Figure 4Di-iii) . The BoneJ plugin (V2) was used to perform morphological analysis including connectivity, surface area to volume ratio, airway diameter and septal thickness 55, 56 . One-way ANOVA with Tukey comparison was used for statistical analysis of microstructural measures. Extended Data Fig. 1 Minimum scan times for quarter and half acquisition modes at voxel sizes presented in this work. Graph showing the signal to noise variation with lateral off-set from centre of rotation. Pearson correlation coefficient (r) = -0.25 and p-value =0.21 (two-tailed test) shown on graph. It should be noted that the exposure time of the camera and final selection of the X-ray filters were set-up on the most off-centre scan, at the angle where the beam was crossing the smallest amount of material, in order to ensure that detector saturation would not occur during scanning. B) showing an example of the regions used to calculate the SNR. Signal was taken from tubule walls while the open tubule lumen was used as the background region. Resolution estimation from fourier shell correlation (FSC) measure. FSC curves (black) with standard deviation (grey shaded) and ½ bit criterion (red hatched) for each voxel size imaged Donor 1 lung. Intercept point is marked and labelled with the equivalent spatial resolution. FSC was calculated in each case using 9 subvolumes cropped at randomly varying spatial locations from the total image volume. Subvolume sizes were varied (200,500 and 1000 voxels). Purkinje cell signal to noise ratio calculation PC= Purkinje cell, BG= Background. Extended Data Fig. 6 . Imaging protocol developments The attenuation scanning protocol was originally developed to image dense fossils and adapted for HiP-CT of complete human organs. In this protocol, the centre of rotation is in the middle of the cylinder used to mount the sample. There are four key principles: 1) single distance phase retrieval using Paganin et al. algorithm coupled with an unsharp mask on the radiographs after phase retrieval; 2) optimization of references absorption profile for local tomography; 3) optimization of dynamical range by adjusting detector saturation level through the sample; 4) a combination of 1, 2, 3 and the attenuation protocol adapted to organs. A) classical scan in edge detection mode. The saturation level of the detector is set on the beam reference without the sample B) Same scan reconstructed using single distance phase retrieval. C) Same scan but references are calculated from an equivalent jar filled with mounting media instead of using pictures of the beam without sample. D) Scan performed off-axis to have a lateral gradient of power in the beam to fit with absorption profile of the sample. Saturation level of the detector tuned through the sample, normal references without sample in the beam. E) Scan in attenuation protocol using references in equivalent jar filled with mounting media, dynamic range optimization and single distance phase retrieval. Scalebar 50mm Refer to Web version on PubMed Central for supplementary material. A) Flow chart of HiP-CT sample preparation and imaging procedure, the ability to select specific higher resolution scan regions based on lower resolution scans provides hierarchical tissue structure images in a data efficient manner. Bi) 2D image slice (25 μm/voxels) showing the location of a series of 2.5 μm/voxel which transect the organs radius (red circles). Bii) HiP-CT scans at 2.5 μm/voxel every 7 mm from the external kidney surface (left) to the centre of the sample (right). The scans are overlapped and stitched to provide a complete organ. The zoom-in show constant level of data quality and precision over the complete transect through the use of the reference scan procedure. C) Photograph of the intact human brain mounted in the PET jar with the ethanol-agar stabilization and reference jar on top. Di) Maximum intensity projection of whole human lung with two randomly selected VOIs imaged at 2.45 μm voxel resolution shown in green (VOI1) and blue (VOI2). 3D reconstructions of the two high-resolution VOIs are shown, with 2D slices in the insets. In the 3D high resolution VOIs the fine mesh of pulmonary blood vessels, complex network of pulmonary alveoli and their septae can be seen. Yellow arrows denote occluded capillaries in 2D slices Dii) Image stack histograms for the green (VOI1) and blue (VOI2) high-resolution VOIs respectively (fixed bin width = 0.0001). Intensity distributions are comparable with positive skew (1.82 and 2.68) and kurtosis (6.44 and 11.88) for VOI1 and VOI2 respectively, histogram intersection is 71% ±3% for fixed bin widths range 1×10 -2 -3×10 -4 . Diii) Box whisker plot showing the structural similarity index between n = 200 pairs of 2D slices independently sampled either from within the same VOI (1-1 and 2-2) or from different VOIs (1-2 and 2-1) for each group respectively; one-way ANOVA (two-sided); p = 0.8765, df = 3, F = 0.23). Boxplots show median = box centreline, interquartile range (75-25 percentile) of data = box bounds, data range excluding outliers = whiskers, values more than 1.5 times the interquartile range above or below box bounds are denoted as outliers -red crosses. E) Single representative slices of high-resolution scans from a HiP-CT image of an intact whole human lung lobe affected by COVID-19 (Donor 3) and a biopsy taken from the same patient's contralateral lung. Both VOIs are captured from the upper peripheral region of each upper lung lobe. In HiP-CT images, fine structure of the tissue including the blood capillaries (red arrows) and alveoli (blue arrows) as well as thin alveolar septae (yellow arrows in insets) are depicted. HiP-CT of brain (A), lung (B), heart (C) kidney (D) spleen (E), where for each organ (i) shows 3D rendering of the whole organ using the 25 μm/voxel scans. Subsequent 2D slices (ii-iv) show the posisitons of the higher-resolution VOIs relative to the previous scan. (v) Shows a digital zoom of the highest resolution image with annotations depicting characteristic structural features: in the brain (molecular layer, ml; granule cell layer, gl; Purkinje cell, pc), in the lung (blood capillary, c; epithelial cell/macrophage, ec/m), in Ai) The three resolution (25, 6 and 1.3 μm/voxel) datasets of HiP-CT taken of a human kidney aligned and overlaid. Aii) shows the measurement of the parenchymal volume semi-automatically segmented (green). Aiii) shows the 6 μm/voxel dataset with the virtual biopsy cylinder in white, the parenchymal volume within the cylinder was measured. A representative 2D slice with inset shows 4 labelled glomeruli. In total 853 glomeruli that were within the cylinder were counted, a blue cross was used to denote the approx. centre of each glomerulus. Aiv) the 1.3 μm dataset with virtual biopsy (red cylinder) shown. The 13 glomeruli within this cylinder were segmented in 3D as shown in the 2D representative slice with inset. B) Comparison of HiP-CT with an aligned histopathological sections (n = 1) (Haematoxylin and Eosin (H&E) stained) taken after all HiP-CT scanning was finished. The left-hand column shows light micrographs of H&E stained histopathological sections and the right-hand column shows 2D tomograms of HiP-CT, yellow boxes denote images Source and beam E -4th generation high energy storage ring with decreased source size / increased spatial coherence I -polychromatic beam for simplified phase contrast approach and high flux Filters / optics E -Use of high purity / highly polished windows and filters to preserved spatial coherence I -Metallic filters and fused silica bars to allow tuning of flux, beam profile and energy Holographic Imaging and Tomography of Biological Cells and Tissues BT -Nanoscale Photonic Imaging Creating High-Resolution Multiscale Maps of Human Tissue Using Multi-beam SEM Correlated Multimodal Imaging in Life Sciences: Expanding the Biomedical Horizon Tridimensional visualization and analysis of early human development Spatiotemporal dynamics and heterogeneity of renal lymphatics in mammalian development and cystic kidney disease Panoptic imaging of transparent mice reveals whole-body neuronal projections and skull-meninges connections Computational fluid dynamics with imaging of cleared tissue and of in vivo perfusion predicts drug uptake and treatment responses in tumours Cellular and molecular probing of intact human organs 7 Tesla MRI of the ex vivo human brain at 100 micron resolution. Sci data Why use synchrotron x-ray tomography for multiscale connectome mapping? A synchrotron X-ray imaging strategy to map large animal brains High-Spatial-Resolution Three-dimensional Imaging of Human Spinal Cord and Column Anatomy with Postmortem X-ray Phase-Contrast Micro-CT 36M-pixel synchrotron radiation micro-CT for whole secondary pulmonary lobule visualization from a large human lung specimen Dense neuronal reconstruction through X-ray holographic nano-tomography Myelinated mouse nerves studied by X-ray phase contrast zoom tomography Phase-contrast zoom tomography reveals precise locations of macrophages in mouse lungs Synchrotron "virtual archaeozoology" reveals how Ancient Egyptians prepared a decaying crocodile cadaver for mummification Wild crocodiles hunted to make mummies in Roman Egypt: Evidence from synchrotron imaging Synchrotron scanning reveals amphibious ecomorphology in a new clade of bird-like dinosaurs Phase--contrast X--ray computed tomography for observing biological soft tissues Refracting Rőntgen's rays: propagation-based x-ray phase contrast for biomedical imaging Propagation-based x-ray phase-contrast tomography of mastectomy samples using synchrotron radiation An upgrade to a bright future The endocast of MH1, Australopithecus sediba Homogenization of sample absorption for the imaging of large and dense fossils with synchrotron microtomography Wing bone geometry reveals active flight in Archaeopteryx Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object The PyHST2 hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities Correction of ring artifacts in X-ray tomographic images Image quality assessment: from error visibility to structural similarity Color Atlas and Textbook of Human Anatomy. Nervous System and Sensory Organs Handbook of cardiac anatomy, physiology, and devices Nephron number, hypertension, renal disease, and renal failure Nephron number, glomerular volume, renal disease and hypertension Biopsy-based estimation of total nephron number in Japanese living kidney donors The Substantial Loss of Nephrons in Healthy Human Kidneys with Aging MRI-based glomerular morphology and pathology in whole human kidneys Applicability of the glomerular size distribution coefficient in assessing human glomerular volume: the Weibel and Gomez method revisited Pathophysiology of COVID-19-associated acute respiratory distress syndrome: a multicentre prospective observational study Pathophysiology, transmission, diagnosis, and treatment of coronavirus disease 2019 (COVID-19): a review Pulmonary Vascular Endothelialitis, Thrombosis, and Angiogenesis in Covid-19 3D virtual pathohistology of lung tissue from Covid-19 patients based on phase contrast X-ray tomography Radiological findings from 81 patients with COVID-19 pneumonia in Wuhan, China: a descriptive study Science forum: the human cell atlas The human body at cellular resolution: the NIH Human Biomolecular Atlas Program Expansion sequencing: Spatially precise in situ transcriptomics in intact biological systems Radiolabeled Peptides and Antibodies in Medicine Butler enables rapid cloud-based analysis of thousands of human genomes Guest editorial deep learning in medical imaging: Overview and future promise of an exciting new technique Single-cell meta-analysis of SARS-CoV-2 entry genes across tissues and demographics Appraising the methodological quality of cadaveric studies: validation of the QUACS scale Computational radiomics system to decode the radiographic phenotype Fiji: an open-source platform for biological-image analysis MorphoLibJ: integrated library and plugins for mathematical morphology with Computing Local Thickness of 3D Structures with Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions All images are shown using 2x binning. that have been pseudo-coloured (from HiP-CT) or converted in grey levels and Author manuscript; available in PMC At 2.5 μm/voxel we observed (3) alveolar obstruction, likely representing clotted blood based on its high intensity; and (4) interstitial thickening of alveolar septae. B) 3D reconstruction of COVID-19 lung with segmentation of two adjacent secondary pulmonary lobules with differing degrees of parenchymal deterioration. Ci) 3D reconstruction of segmented acini structure within the SARS-CoV-2-uninfected (control) lung and Cii) the SARS-CoV-2 infected lung. Di)-Diii). 3D reconstruction of representative VOI at the high resolution (2.5 μm voxels) for the control, COVIDs and COVID C groups respectively. Duplicated volumes show visual representations of the airspace-tissue interface in COVID-19 lung, where a smaller distance between a voxel of airspace and a voxel of tissue is coloured blue whereas larger distances are coded yellow. Div-Dviii) Boxplots showing quantitative comparisons between n = 6, independent COVID S , COVID C and control, VOIs. Boxplots show data median -box centreline, interquartile range (25 -75 percentile) of data -box bounds, data range without outliers -whiskers, outliers were considered as values 1.5 times above or below the box bounds. Quantification of mean surface area to volume ratio Shows the distribution of airspace diameters for all six VOIs in each group modal values for COVID C , COVID S and Control = 8.9, 152 and 351 μm respectively Image data that support the findings of this study are publicly available (with sign in) from the ESRF data repository. human-organ-atlas.esrf.euIndividual DOIs for all datasets are listed in Supplementary