key: cord-0710229-8kpricmh authors: Kolb, Jan P.; Hättich, Annika; Strahl, André; Rolvien, Tim; Hennigs, Jan K.; Barg, Alexej; Frosch, Karl-Heinz; Hartel, Maximilian J.; Schlickewei, Carsten title: Does the COVID-19 personal protective equipment impair the surgeon’s performance? date: 2022-03-19 journal: Arch Orthop Trauma Surg DOI: 10.1007/s00402-022-04416-2 sha: ff3df4a9bd90d82688952f5b32fefcba76952215 doc_id: 710229 cord_uid: 8kpricmh INTRODUCTION: Despite increasing vaccination rates, new viral variants of SARS-CoV-2 (severe acute respiratory syndrome coronavirus type 2) are advancing the COVID 19 (coronavirus disease 2019) pandemic and continue to challenge the entire world. Surgical care of SARS-CoV-2 positive patients requires special protective measures. We hypothesized that "COVID-19" personal protective equipment (PPE) during surgery of SARS-CoV-2 positive or potentially positive patients would negatively affect the surgeon and thus the surgical outcome. MATERIALS AND METHODS: Ten experienced trauma surgeons participated in the study. Each surgeon performed two simulated surgeries of a distal tibial fracture on a Sawbone® under standardized conditions either wearing regular PPE or special COVID-19 PPE. Baseline values at rest were acquired for heart rate, blood pressure, saturation of peripheral oxygen (SpO(2)), respiratory rate and capillary blood gas (CBG) analysis including capillary partial pressure of oxygen (pO(2)) and carbon dioxide (pCO(2)), followed by four different standardized tests of attentional performance (TAP). Subsequently, the surgeon performed the first surgery according to a randomly determined order, with regular or COVID-19 PPE conditions in an operation theatre. After each surgery vital signs were acquired and CBG and TAP were performed again. RESULTS: In our simulated surgical procedure heart rate, respiratory rate, systolic and diastolic blood pressure did not show relevant differences. Percutaneously measured SpO(2) decreased with additional layers of PPE, while CBG parameters were not affected. TAP tests showed a significant impairment of attention if PPEs were compared to the baseline, but both PPEs had similar results and no meaningful differences could be measured. CONCLUSIONS: According to our results, for surgical procedures additional PPE required during COVID-19 pandemic does not relevant affect the surgeon’s mental and physical performance. Surgeries under COVID-19 PPE conditions appear safe and do not increase patient risk. LEVEL OF EVIDENCE: Level I. The COVID-19 pandemic continues to challenge the entire world [2, 3, 5, 6, 11, 14, 19] . While global vaccination strategies are currently implemented, new viral variants of SARS-CoV-2 continue to emerge and contagion rates remain high across the globe [17, 23] . High infection rates inevitably constitute an increased likelihood of SARS-CoV-2-positive patients requiring emergency surgery or non-deferrable interventions. In addition, there are countless procedures, where surgery must be performed due to medical emergency, even though there was insufficient time to safely determine the patient's COVID-19 status and rule out a risk of infection for the medical staff. As such, additional precautions must be taken including the use of special personal protection equipment (PPE) to prevent airborne transmission of the SARS-CoV-2 not only for personal protection of healthcare workers but also to maintain a highly functioning health care system in general [1, 2, 10, 16, 20] . The WHO (World Health Organization) ad hoc COVID Infection Prevention and Control Guidance Development Group (COVID IPC GDG) recommends protective masks with additional protection (e.g., N95, N99, FFP2, FFP3, or equivalent). High infection rates among healthcare workers (vaccinated, unvaccinated, or recovered of COVID- 19) can only be prevented through the use of appropriate PPE. Thus, in addition to standard PPE at least three layers of partially fluid-repellent and waterproof clothing including a liquid-repellent surgical mask on top of an FFP2 mask and medical goggles are required for standard operative procedures on SARS-CoV-2 positive patients by local authorities. Trauma and orthopaedic surgeons wear a lead gown as extra protective equipment. We hypothesized that the additional PPE measures, meant to protect the staff against COVID-19 in an operation theatre, leads to substantially increased physical and mental stress resulting in decreased alertness in surgeons. This might have direct influence on the surgeon's attention, accuracy of surgical steps performance, the intraoperative patient safety, and negatively affect the surgical outcome. In this study, we explored these questions simulating the surgical treatment of a distal tibial plafond fracture using a saw-bone model in a regular operation theatre either in "standard" or "COVID-19" PPE. To measure the surgeon's workload, vital signs, and capillary blood gas (CBG) analysis were performed before and after simulated surgery. The attentional function, as a basic prerequisite for general performance and alertness, was assessed with four different standardized attention subtests from the test of attentional performance (TAP) [26] . This study was conducted in accordance with the Declaration of Helsinki and the Guidelines for Good Clinical Practice [12] . The Medical Board of Hamburg (Ärztekammer Hamburg 15022021DH) approved this study. Ten in traumatology fellowship trained trauma surgeons (9 males, 1 female) with a mean age of 37.2 ± 3.9 years participated in the study (Table 1 ). All surgeons voluntarily agreed to participate in this study were informed comprehensively about the study and gave written consent. The data collected were stored and analyzed anonymously. Mean years of experience were 11 years (range, [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] . Each surgeon performed two simulated surgeries of a distal tibial plafond fracture using Sawbone® under realistic and standardized conditions either wearing regular ("standard") PPE or special COVID-19 PPE. Surgery simulation took place in a regular operation theatre with a lamina air flow system under constant room temperature (18 °C). The study was carried out during normal working hours. The order of the surgeons and the test setting was determined at random by drawing two sealed envelopes. The first envelope determined the order in which the surgeons performed the surgery (numbers 1 to 10). To achieve a statistically balanced distribution, the second envelope determined whether the surgeons performed the first operation with standard PPE in an operation theatre or with COVID-19 PPE. For standard and the COVID-19 PPE, current standard guidelines at our University Medical Center Hamburg-Eppendorf were followed as described below (Table 2) . Before surgery, the following parameters were collected from each surgeon: age, sex, body weight, height, smoking status and history, and previous pulmonary diseases. Baseline values at rest were acquired for heart rate, blood pressure (Riva Rocci method), peripheral oxygen saturation (SpO 2 ), respiratory rate and capillary blood gas (CBG) analysis including capillary partial pressure for oxygen (pO 2 ) and carbon dioxide (pCO 2 ), followed by four different standardized subtests of TAP (see below). Subsequently, the surgeon performed the first surgery according to the randomly determined order, with standard or COVID-19 PPE conditions in an operation theatre. As basic PPE each surgeon wore surgical waterproof boots, a surgical scrub suit, a surgical hood with ties, a waterproof X-ray protection apron and one surgical face mask. Basic PPE in the operation theatre consisted of additional sterile gown and double sterile gloves, after surgical hand preparation. For COVID-19 PPE the surgical scrubbing routine was adapted to the most recent protocol being used. In addition to basic PPE the surgeon wore a FFP2 mask under the surgical face mask (double masking), medical safety googles, and a non-sterile fluid-repellent long gown over the waterproof X-ray protective apron. After surgical hand preparation the surgeon was provided with a sterile gown and double sterile gloves. The distal tibial plafond fracture was reduced and stabilized with standard instruments and an angular stable plate osteosynthesis (Locking Compression Plate (LCP® DePuy Synthes), Fig. 1A , B). A standard operating time of 30 min was set for each procedure. After the time, the surgery was terminated regardless of the surgical progress. Vital signs, CBG and TAP were determined again. The whole procedure was repeated for the second surgery using the other PPE scheme. Following every simulated surgery, surgeons reported subjective stress and exhaustion under standard and COVID-19 conditions on a 11-item numerical scale from 0 to 10. (0 = not exhausting at all to 10 = maximum exhausting) [7] . Vital signs measurement was carried out using a monitor system (Draeger Infinity® Delta monitor) for non-invasive blood pressure measurements (Riva Rocci method) on the upper arm (BP), heart rate (beats per minute, bpm) and percutaneous oxygen saturation (SpO 2 in percent, via pulse oximeter). The respiratory rate (RR) was counted over a period of 60 s. CBG was performed as arterialized capillary blood gas analysis on the earlobe. To reduce venous mixing of the blood sample, the earlobe was rubbed with a vasodilating ointment (Finalgon®, Boehringer Ingelheim) before puncture and blood draw into heparinized glass capillaries. CBG analysis was also performed (Radiometer ABL90, Flex). Data for oxygen partial pressure (pO 2 ) and carbon dioxide partial pressure (pCO 2 ), pH value and hydrogen carbonate (HCO 3 ) were extracted. Participant's attention was assessed with four subtests of the standardized computer-assisted TAP Version 2.3.1: Alertness, Go/No-Go, Flexibility and Divided Attention [27, 28] . The alertness subtest measures the reaction time in milliseconds (ms) to a given visual stimulus of the screen with and without an auditory warning signal. When the stimuli are displayed, a button must be pressed as quickly as possible. The Go/No-Go subtest assessed the participant's inhibitory control. The test presents sequential ether a target or a nontarget stimulus, whereby the button only must be pressed on target stimuli. Both, reaction time for correct responses and the number of errors (wrong marks) are recorded. The Flexibility subtest is a "set shifting" task. To the right and left side of the screen an angular and a round figure are presented simultaneously. During the task, the target stimuli change constantly from angular to round figure and participants must chose with a left and right button the complementary target stimulus (e.g., in the sequence: "round"-"angular"-"round"-"angular" etc.). Divided Attention presents a visual and an auditory dual task simultaneously. The visual task involves pressing a button when four crosses form a square on a matrix, while in the auditory test a button must be pressed when the same tone is played twice in a row. Reaction time, the number of errors (wrong marks), and the number of missing are recorded. All participants were tested individually in the surgery room at three timepoints using a computer in a random test sequence. The first test was performed before the start of the simulation surgery (baseline). Furthermore, two tests were carried out after each surgery. The test instructions were presented in writing and explained in addition, if necessary, by an experienced supervising psychologist. Before each subtest was performed, a trial run was completed to identify comprehension and execution problems. The required sample size for this study was calculated based on TAP manual. The expected effect size was estimated from the minimal clinical important difference (MCID) and the standard deviation (SD) of the norm sample for the Divided Attention subtest. The Divided Attention subtest was chosen for this purpose as it reflects the ability needed to divide attention to simultaneously ongoing processes as required during complex surgery. MCID, as patient derived scores reflecting meaningful changes, was 222.2 ms for reaction time of visual divided attention and 180.5 ms for auditory divided attention. Considering the SD of the norm sample of the Divided Attention subtest, a large effect size of 1.44, respectively, and 1.48 could be derived from these values. With an alpha risk of 0.05 and a statistical power of 0.8, a total sample size of n = 5 samples was calculated. To account for the large effect size calculated, it was decided to double the sample size to n = 10, during the design of the study. All data were analyzed using IBM SPSS Statistics version 26.0 (IBM, Armonk, NY) and GraphPad Prism 9 (GraphPad Software, La Jolla, CA). Continuous variables are expressed as mean ± SD, while categorial variables are expressed as number and percentage. Shapiro-Wilk normality test and Kolmogorov-Smirnov test were performed to determine if the data were normally distributed. Spearman coefficient was used for correlation of nonparametric data. The median reaction times and errors were evaluated using one-way repeated measures ANOVAs for normally distributed data or Friedman-test for non-normally distributed data to determine whether significant differences exist among measuring conditions. The level of significance for all tests was set at P ≤ 0.05. Vital signs were collected at baseline, before and after the simulated surgeries. We did not find any significant differences in systolic and diastolic blood pressure, heart rate or respiratory rate between individuals at baseline or across PPE conditions. SpO 2 under room air showed a slight decrease with additional PPE measures but no statistically significant differences between any two of the three conditions were detected. In addition, while we detected minor non-significant changes in the CBG parameters pO 2 , pCO 2 and pH across PPE conditions, all remained well within normal limits (Table 1) . Performing surgery with COVID-19 PPE was considered statistically more distressing (4.5 ± 1.3) than with standard PPE (2.3 ± 0.7; P = 0.005). Moreover, a non-significant trend towards lower pO 2 values (r = -0.354, P = 0.316) and higher pCO 2 values (r = 0.617, P = 0.058) in the BGA with higher subjective stress during surgery while wearing the "COVID-19″ PPE was observed. The alertness subtest did not reveal any significant differences regarding the mean values or standard deviations between baseline and either standard or COVID-19 PPE ( Fig. 2A-D) . However, other TAP subtests showed a significant difference for both PPEs compared to the baseline. Namely, both standard and COVID-19 PPE had a significant impact on reaction time in the flexibility subtest (p = 0.003) with a strong negative effect on reaction time (Fig. 3A, B) . Although no significant differences were found regarding the absolute number of error rates (Fig. 3C ), compared to baseline speed-accuracy-index was significantly decreased across all PPE conditions (P = 0.034) (Fig. 3D) . No difference between standard and COVID-19 PPE was detected. In the divided attention subtest, there were no differences for auditory or visual divided attention, or divided attention errors between baseline, standard, and COVID-19 PPE ( Fig. 4A-F) . Despite no change in reaction times in the Go-No-Go Go/No-Co subtest (Fig. 5A, B) , the error rate increased when PPE was used (P = 0.025) (Fig. 5C) , regardless of PPE type (P = 0.081). In summary, results in all four TAP subtests were partially reduced but within the standard range, either for standard or COVID-19 PPE (Figs. 2, 3, 4 , 5) . In the present study, we investigated whether the additional PPE measures as extra infection prevention during the COVID-19 pandemic correlated with increased physical and psychological distress in trauma surgeons. During the simulated surgical procedure heart rate, respiratory rate, systolic and diastolic blood pressure did not show any relevant differences. Percutaneously measured SpO 2 decreased with additional layers of PPE, while CBG parameters were not affected. Importantly, all measured values (vital signs and CBG) remained constantly within their respective reference range and are, therefore, likely without relevant physiological impact [13, 21, 22] . In contrast, a recent study in oral surgeons reports much more pronounced PPE-related differences in heart rate and oxygenation even when performing short surgical procedures [18] . In keeping with possible underlying confounders, Fig. 2 Test of attentional performance-subtest alertness. Comparison of response times in milliseconds between the three investigated groups at baseline, operating with surgical mask, and operating with FFP2 mask in the test results A Alertness without an acoustic signal, B standard deviation of Alertness without an acoustic signal, C Alertness with an acoustic signal, and D standard deviation of Alertness with an acoustic signal in the present study surgeons were older and likely more experienced. This in line with reports showing heightened intraoperative stress levels in less experienced surgeons [9, 24] . In addition to physiological impact, PPE-related mental stress was assessed using TAP tests and a self-reported 10-item stress indicator scale. TAP tests showed a significant impairment of attention. Both standard and COVID-19 PPE had a significant impact on the reaction time in the flexibility subtest and a strong negative effect on the reaction time. Although no significant differences were found regarding the errors in this subtest, there was a significant decrease in the speed-accuracy-index across all conditions. For the Go/ No-Go subtest, here, no change in the reaction times were documented, but significantly more errors were recorded for both PPE groups. The results of the TAP test show that even wearing "normal" PPE including X-ray protection leads to a significant impairment of attention. This is also evident for COVID-19 PPE. Both PPE in combination with X-ray protection lead to a negative influence on reaction time, while the error rate remains the same. This is in contrast to the results of the Go/ No-Go test, which could not prove any impairment of reaction time, but showed a significantly higher error rate for PPE groups. We have no explanation for the contradictory effect on reaction time in the two tests. However, the significant increase in error rate in the Go/No-Go test could be explained by the complexity of the test after the simulated surgery. Nevertheless, the studies show that both PPE have a significant effect on the surgeon. However, this effect has no significant impact in the direct comparison of the two PPE groups against each other. Due to the SARS-CoV2 pandemic CDC and ECDC widely recommend PPE, not only in hospitals. Despite rising vaccination rates viral variants of SARS-CoV-2 differ from conventional virus variants in their pathogen characteristics, such as transmissibility, virulence, or susceptibility. Some variants remain infectious even to vaccinated or recovered individuals. Some variants remain infectious even for vaccinated or recovered individuals. Appropriate "COVID-19" PPE and adequate rest periods continue to be considered key factors in protecting patients and medical staff and to reduce the risk of negative psychological consequences [8] . Fikenzer et al. reported reduction of ventilation, cardiopulmonary exercise capacity and comfort by surgical masks and highly impairment by FFP2/N95 face masks [4] . We hypothesized that these could lead to increased physical stress, reduced air supply, and decreased alertness in surgeons, which may have a direct influence on the surgeon's attention, the patient safety and negatively affect the surgical outcome. In comparison the oxygen content measured percutaneously under "COVID-19″ PPE was lower when compared to the baseline and "standard" PPE conditions but without falling below the normal value or statistical relevance. Subjectively, surgery was perceived as more stressful under "COVID-19″ conditions than under "standard" conditions. TAP tests showed a significant impairment of attention if the PPEs were compared to the baseline, but both PPEs had similar results and no differences for both PPEs could be measured. Although these results imply an impact of PPE, we did not find any relevant differences between the two PPEs. Although the measured values showed a negative trend for "COVID-19″ PPE, normal values could always be measured here as well. This suggests that surgical management of a SARS-CoV-2 positive patient in emergency situations may lead to equally good results as in non-infected patients from surgery performance point of view. In our study, we did not find any relevant differences between "standard" PPE and "COVID-19″ PPE. The presented study has some limitations. The simulated surgeries are a major limitation of our study, even though the entire setting from operating room to the instruments used correspond to real surgeries. However, to create standardized conditions, to exclude the influence of different types and lengths of surgery, and to avoid putting real patients at unnecessary risk, we chose the setting described. Procedure time was rather short with a total of 30 min. However, emergency procedures are primarily to stabilize the patient (e.g., use of external fixators for the stabilization of polytrauma patients) and should, therefore, generally be kept as short as possible before the patient can be transferred to an intensive care unit. In addition, blood was taken from the earlobe for the CBG tests. Although arterial blood sampling represents the gold stand for blood gas analysis, multiple studies have found that CBG analysis provides reliable and clinically useful results [15, 25] . According to our results, for short surgical procedures additional PPE required during COVID-19 pandemic does not substantially affect the surgeon's mental and physical performance. All measured data remained within the normal range at all times, and no significant differences in the attentional performance tests were noted between the special COVID-19 PPE and the regular, "standard" PPE. Our pilot study suggests that surgical procedures using COVID-19 PPE conditions are safe and do not increase the patient's risk by adding stress to the surgical procedure. Author contributions JPK: study conception and planning, surgery performance, data collection, data analysis, and manuscript writing. AH: surgery performance, data analysis, and manuscript writing. AS: statistical analysis, analysis of attentional performance, and manuscript writing. TR: surgery performance, data analysis, and manuscript writing. JKH: vital signs measurement and analysis, capillary blood gas measurement and analysis, and manuscript writing. AB: literature review, statistical analysis, and manuscript writing. KHF: manuscript writing and project supervision. MJH: surgery performance, data collection, data analysis, and manuscript writing. CS: study conception and planning, writing and submission of ethical approval, surgery performance, data collection, data analysis, manuscript writing, and project supervision. Funding Open Access funding enabled and organized by Project DEAL. The authors have no conflict of interest to declare. The authors declare that ethical approval was granted by the Medical Board of Hamburg prior to the study (Ärztekammer Hamburg 15022021DH). The consent was signed prior to the study beginning by all involved co-authors. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/. Infection prevention measures for orthopaedic departments during the COVID-2019 pandemic: a review of current evidence Testing in a pandemic -Improving access, coordination, and prioritization The effect of COVID-19 lockdowns on paediatric lower limb orthopaedic presentations Effects of surgical and FFP2/N95 face masks on cardiopulmonary exercise capacity Effect of coronavirus (COVID-19) pandemic on orthopedic trauma patients presenting in the emergency department of a maximum care hospital and level 1 trauma center Preoperative ferritin and hemoglobin levels are lower in patients with a history of COVID-19 but blood loss and transfusion requirements are not increased Three studies supporting the initial validation of the stress numerical rating scale-11 (Stress NRS-11): A single item measure of momentary stress for adolescents and adults Occurrence, prevention, and management of the psychological effects of emerging virus outbreaks on healthcare workers: rapid review and meta-analysis Intraoperative stress in cardiac surgery: attendings versus residents Face masks to prevent transmission of COVID-19: A systematic review and meta-analysis A novel coronavirus emerging in China -Key questions for impact assessment Revising the Declaration of Helsinki: a fresh start Arterial desaturation during exercise in man: implication for O2 uptake and work capacity Mental health and the Covid-19 pandemic Capillary blood gas as a substitute for arterial blood gas: a metaanalysis COVID-19 strategy in organizing and planning orthopedic surgery in a major orthopedic referral center in an area of Italy severely affected by the pandemic: experience of the Department of Orthopedics, University of Padova Grinsztejn B et al (2021) Safety and efficacy of single-dose Ad26. COV2.S vaccine against Covid-19 Protective face masks: Effect on the oxygenation and heart rate status of oral surgeons during surgery Assessing the spreading potential of an undetected case of COVID-19 in orthopaedic surgery Aerosol generating procedures in trauma and orthopaedics in the era of the Covid-19 pandemic Variability of arterial blood gas values in stable patients in the ICU Blood gases at rest and during exercise in patients with alpha1-Pi deficiency Incident SARS-CoV-2 infection among mRNA-vaccinated and unvaccinated nursing home residents Intraoperative stress experienced by surgeons and assistants. Ophthalmic Surg Lasers Arterial versus capillary blood gases: a meta-analysis Applied neurophysiology of attention: Theory, diagnosis and rehabilitation A test battery for attentional performance Die Testbatterie zur Aufmerksamkeitsprüfung (TAP) Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations Acknowledgements We thank Gerhard Engler, MD, Department of Neurophysiology and Pathophysiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany, for providing us with the Test of Attentional Performance software.