key: cord-0708573-deyvccw9 authors: Parsons, Teresa L.; Kryszak, Lindsay A.; Marzinke, Mark A. title: Development and Validation of Assays for the Quantification of β-D-N(4)-hydroxycytidine in Human Plasma and β-D-N(4)-hydroxycytidine-Triphosphate in Peripheral Blood Mononuclear Cell Lysates date: 2021-09-02 journal: J Chromatogr B Analyt Technol Biomed Life Sci DOI: 10.1016/j.jchromb.2021.122921 sha: 55c10d44c19220ed656046318e07a71b72566d08 doc_id: 708573 cord_uid: deyvccw9 The novel antiviral prodrug molnupiravir is under evaluation for the treatment of SARS-CoV-2. Molnupiravir is converted to β-D-N(4)-hydroxycytidine (NHC), which is the primary form found in systemic circulation. β-D-N(4)-hydroxycytidine-triphosphate (NHCtp) is the bioactive anabolite produced intracellularly. Sensitive and accurate bioanalytical methods are required to characterize NHC and NHCtp pharmacokinetics in clinical trials. Human K(2)EDTA plasma or peripheral blood mononuclear cell (PBMC) lysate were spiked with NHC (plasma) or NHCtp (PBMC), respectively. Following the addition of isotopically-labeled internal standards and sample extraction via protein precipitation or lysate dilution, respectively, samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Methods were validated in accordance with FDA Bioanalytical Method Validation recommendations. NHC can be quantified in plasma with a lower limit of quantification (LLOQ) of 1 ng/mL; the primary linearity of the assay is 1-5000 ng/mL. Assay precision and accuracy were ≤ 6.40% and ≤ ± 6.37%, respectively. NHC is unstable in whole blood and has limited stability in plasma at room temperature. The calibration range for NHCtp is 1-1500 pmol/sample, and the assay has an LLOQ of 1 pmol/sample. Assay precision and accuracy were ≤ 11.8% and ≤± 11.2%. Ion suppression was observed for both analytes; isotopically labeled internal standards showed comparable ion suppression, resulting in negligible (<5%) relative matrix effects. Sensitive, specific, and dynamic LC-MS/MS assays have been developed and validated for the quantification of NHC in plasma and NHCtp in PBMC lysates. The described methods are appropriate for use in clinical trials. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pathogen, which is a singlestranded RNA virus, causes COVID-19 [1] . COVID-19 is associated with a heavy disease burden and can severely impact several organ systems, including the lungs, kidneys, liver, muscles, and nervous system [2] . With the global spread of SARS-CoV-2 beginning in early 2020, significant efforts have been made in both vaccine research for the prevention of COVID-19, as well as in the identification and utilization of novel or repurposed therapeutics for the management of those with symptomatic COVID-19. To date, ten agents have received emergency use authorization (EUA) by the US Food and Drug Administration (US FDA) for the management of patients with COVID, including one antiviral agent, the adenosine nucleoside analog remdesivir [3] . Other investigational agents are also being evaluated in clinical trials, including the ribonucleoside analog molnupiravir, also known as EIDD-2801 or MK-4482 [4, 5] . Molnupiravir is an orally bioavailable isopropylester prodrug of β-D-N 4 -hydroxycytidine (NHC; EIDD-1931) , which has broad antiviral activity against a number of RNA viruses based on in vitro and animal studies [6] [7] [8] [9] . In a pre-clinical Venezuelan equine encephalitis virus mouse model, NHC was taken up by target tissues and anabolized to β-D-N 4 -hydroxycytidine-triphohsphate (NHCtp; EIDD-2061), the bioactive anabolite of NHC [10] . NHCtp is a viral RNA polymerase substrate, leading to the induction of lethal viral mutagenesis and impairment of viral fitness [4, 6] . Studies in primary human cultures have shown that NHC is active against several coronaviruses, including SARS-CoV, SARS-CoV-2, and Middle East respiratory syndrome coronavirus (MERS-CoV) [11] . Molnupiravir treatment in an immunocompromised mouse model demonstrated inhibition of SARS-CoV-2 replication in vivo, reinforcing the potential for the compound in the management of COVID-19 [12] . At the 2021 Conference on Retroviruses and Opportunistic Infections (CROI), data from a phase 2a clinical trial showed that treatment with molnupiravir resulted in a significant reduction in time to negativity of infectious virus from nasopharyngeal swabs as compared to placebo in participants with COVID-19 [5] . As molnupiravir continues to be evaluated for the treatment of SARS-CoV-2, a more thorough understanding of drug pharmacology will be required, especially as several studies include dose escalations to assess drug safety and tolerability. Thus, bioanalytical assays will be needed to measure the primary form in systemic circulation (NHC) as well as its active intracellular anabolite (NHCtp). Previous studies refer to the measurement of NHC and its anabolites via liquid chromatography-tandem mass spectrometry (LC-MS/MS); however, these assays were chiefly employed for the determination of drug concentrations in pre-clinical trials, and specific validation metrics were not described [10, 13] . In a recent phase 1 study, which assessed the tolerability, safety and pharmacokinetics of molnupiravir, molnupiravir and NHC concentrations in human plasma were quantified using assays with lower limits of quantification (LLOQs) of 5 ng/mL; NHCtp was not measured in that study [4] . In order to support ongoing and future work focused on molnupiravir, herein we describe the development and validation of rapid bioanalytical methods for the quantification of NHC in human plasma and intracellular NHCtp in peripheral blood mononuclear cells (PBMC) lysates. NHC and NHCtp, as well as their respective internal standards, β-D-N 4 -hydroxycytidine-13 C 5 (NHC-IS) and β-D-N 4 -hydroxycytidine-triphosphate- 13 For the quantification of NHC in K 2 EDTA plasma, standards were prepared at final concentrations of 1, 5, 25, 100, 500, 1000, 2500, and 5000 ng/mL. QCs in K 2 EDTA plasma were prepared at the following levels: 1 (lower limit of quantification, LLOQ), 3 (Low), 250 (Mid), 4000 (High), and 15000 ng/mL (Dilution QC). The NHC-IS used was prepared at a final stock concentration of 50 ng/mL. For the quantification of NHCtp in PBMC, calibrator and QC stocks were prepared in 70:30 acetonitrile:water. Calibration standards were prepared by spiking blank PBMC lysate at 2x10 6 cells/mL with appropriate volumes of working stock solutions. Calibrator and QC concentrations were assigned as pmol/sample, to reflect the volume of sample (0.1 mL) analyzed for intracellular anabolite quantification. Final NHCtp concentrations of calibration standards in PBMC lysate were 1, 5, 25, 100, 500, 1000, and 1500 pmol/sample. NHCtp QC materials in PBMC lysate were prepared at 1, 3, 250, 1200, and 6000 pmol/sample, and are assigned the LLOQ, low, mid, high and dilution QC levels, respectively. NHCtp-IS was dissolved separately in 70:30 acetonitrile:water for a final concentration of 2000 pmol/mL. For quantification of NHC in human plasma, sample preparation was carried out via protein precipitation using a 96-well Captiva 0.45 μm protein precipitation filtration plate (Agilent Technologies, Santa Clara, CA). Briefly, 50 µL of sample was pipetted into the Captiva plate wells, followed by 50 µL of NHC-IS solution. Next, 0.5 mL of acetonitrile was added to each well and samples were incubated for 5 minutes. Samples were eluted via vacuum filtration, evaporated to dryness, and reconstituted in 0.6 mL of 0.1% formic acid. For quantification of NHCtp in PBMC lysate, 100 µL of sample was pipetted into a 96-well collection plate (Waters Corporation, Milford, MA), followed by 25 µL of NHCtp-IS. Samples were evaporated to dryness under nitrogen, and reconstituted in 100 µL water. For NHC quantification in human plasma, 10 µL of reconstituted material was introduced into a Waters Acquity UPLC system interfaced with an API 5000 mass analyzer with an electrospray ionization (ESI) source (SCIEX, Redwood City, CA). Chromatographic separation occurred using a Zorbax Eclipse Plus C18, narrow bore, 2.1 x 50 mm UPLC column with a 3.5 µm particle size (Agilent Technologies) with a mobile phase system of 0.1% formic acid in water (mobile phase A; MPA) and 0.1% formic acid in acetonitrile (mobile phase B; MPB). NHC was separated via a gradient elution at a flow rate of 0.4 mL/min. The full LC gradient is provided in Supplemental Table 1 For quantification of NHCtp in PBMC, 20 µL of reconstituted material was introduced into a Shimadzu Nexera X2 HPLC system (Shimadzu Corporation, Kyoto, Japan) interfaced with a QTRAP 6500 mass analyzer with an ESI source (SCIEX). Chromatographic separation occurred using a Scherzo SM-C18, 3 x 50 mm column with a 3.0 µm particle size (Imtakt USA, Portland, OR) with a mobile phase system of 50 mM ammonium formate: 5 mM ammonium hydroxide (MPA) and 80 mM ammonium formate: 8 mM ammonium hydroxide in [80:20] water: acetonitrile (MPB). Analytes were eluted under a gradient; the assay was operated at a flow rate of 0.75 mL/min. The full LC gradient is provided in Supplemental Table 1 . NHCtp was monitored in multiplexed SRM and negative ionization modes. NHCtp and its internal standard were monitored at the following transitions: NHCtp: 497.600 158.700 m/z; NHCtp-IS: 502.800 158.700 m/z. The run time of the assay was 3.00 min; NHCtp eluted at 0.33 min. Data were acquired using Analyst® 1.7.1 (SCIEX). Calculations for validation assessment, which included precision, accuracy, stability, and matrix effects, were performed using Microsoft Office Excel 2016. Outliers were defined using the Grubbs' Outlier Test. The LC-MS/MS assays for the quantification of NHC in human plasma and NHCtp in PBMC were validated in accordance with the United States Food and Drug Administration (FDA) Guidance for Industry, Bioanalytical Method Validation recommendations [14] . Intra-and inter-assay precision and accuracy, linearity, dilutional integrity, selectivity, stability, matrix effects, and carryover were all evaluated. Precision and accuracy studies were conducted by evaluating QC materials prepared at the LLOQ, low, mid and high QC concentrations. Replicates of 6 at each level were evaluated to assess intraassay precision and accuracy; inter-assay precision and accuracy were evaluated over 3 (NHCtp in PBMC) or 4 (NHC in human plasma) independent runs. Observed means, standard deviations (SDs) and coefficients of variation (%CV) were calculated for all QC levels. Precision was determined as the %CV of the peak area ratio of NHC or NHCtp to their respective internal standards. Accuracy was characterized by the percent deviation (%DEV), which is a measure of the difference between mean observed and theoretical QC concentrations divided by the theoretical concentration and multiplied by 100. Calibration standards were analyzed at the beginning and end of each analytical run. Standard curves for NHC (plasma) and NHCtp (PBMC) were calculated using the analyte to internal standard peak area ratio and determined using quadratic (plasma) or linear (PBMC) regression with 1/x 2 weighting. Extended linearity was evaluated through the preparation of dilution QCs at concentrations three times the upper limit of quantification (ULOQ) for NHC in plasma (15000 ng/mL) and at four times the ULOQ for NHCtp in PBMC (6000 pmol/sample). For the plasma assay, the dilution QC was diluted up to 500fold with blank K 2 EDTA human plasma. For the PBMC assay, the dilution QC was diluted up to 50-fold with 70:30 methanol: water. Additionally, two-and five-fold dilutions of mid and high QCs were prepared for both matrices. Precision and accuracy were assessed by setting theoretical values at calculated diluted concentrations. Carryover was determined by analyzing four consecutive samples at the ULOQ and evaluating post-injection blanks to ensure that the observed peak areas observed was <20% of the LLOQ. Sample matrix stability was assessed by incubating QC-spiked human plasma and PBMC lysate at room temperature for 24 and 72 hours (plasma) or 77 hours (PBMC lysate) prior to extraction and analysis. For the plasma assay, an independent set of QCs spiked in whole blood were maintained at room temperature for 2, 4, and 24 hours prior to processing and storage at ≤ -70°C. An additional set was also maintained on ice for 4 hours. Plasma from treated samples was compared to those of whole blood samples which were immediately processed post-spiking. For all stability challenges, acceptability was determined as %DIF ≤15% ([(treated -untreated) /untreated]*100) or as %DEV ([(observedtheoretical)/theoretical]*100). Post-preparative stability was assessed by storing extracted low, mid, and high QC samples (n = 6) in 0.1 % formic acid (plasma) or water (PBMC lysate) at 2-8°C for 72 hours (plasma) and 137 hours (PBMC lysate) and then injecting with a fresh calibration curve. Reinjection stability was assessed by preparing extracted QC samples in 0.1 % formic acid (plasma) or water (PBMC lysate) at the low, mid, and high concentrations (n=6). They were injected immediately and then left at 10°C for 72 (plasma) or 15°C for 52 (PBMC lysate) hours and reinjected. Freeze-thaw stability studies were performed using QC samples in replicates of four (plasma) or six (PBMC lysate) that were frozen and thawed, for approximately 2 (plasma) or 6 hours (PBMC lysate), through three cycles. Stability was evaluated by comparing observed values to freshly thawed and analyzed samples. Long-term stability was assessed by analyzing QC materials stored at ≤ -70°C for up to 260 (plasma) or 148 days (PBMC lysate) off of a freshly prepared standard curve and was measured as %DEV. Selectivity was performed by analyzing 6 independent lots of drug-free human plasma or PBMC. Samples were prepared as described above. Chromatographic review was performed to monitor for potentially interfering substances at the expected retention times and ion transitions. For NHC and NHCtp, blank sample peak areas were required to be less than 20% of the LLOQ. For internal standards, the blank sample peaks areas were required to be less than 5% of the IS response. For human plasma and PBMC lysates, the effects of ion suppression or enhancement were assessed for NHC and NHC-IS or NHCtp, and NHCtp-IS, respectively, following experiments previously described by Matuszewski and colleagues [15] . Un-extracted materials were prepared at low, mid, and high QC concentrations in the absence of sample matrices. Post-extracted materials were prepared by spiking post-extracted matrix samples with NHC and NHC-IS or NHCtp, and NHCtp-IS, respectively, at low, mid, and high QC concentrations. For the human plasma assay, pre-extracted sets were analyzed following the previously described sample preparation conditions. For the PBMC lysate assay, the Matuszewski approach could not be used to measure recovery or process efficiency, as the procedure utilizes direct analysis in lieu of an extraction method. Therefore, recovery was defined as the average of the inter-assay mean concentrations divided by the theoretical concentration times 100 across the analytical measuring range of the assay. Pre-(plasma) and post-extracted (plasma and PBMC lysate) sets were evaluated using independent lots of human plasma (n=6) or PBMC lysate (n=6). Peak areas for analytes and internal standards were used to determine overall matrix effects, extraction efficiency, and processing efficiency. Cell concentration experiments were performed to determine the effect of PBMC concentration on NHCtp recovery. PBMC lysates were prepared at 0.2, 2, 10, and 20 x 10 6 cells/mL. The 2 x 10 6 PBMC lysate condition was assigned the control as this is the concentration at which calibrators and QCs were prepared. Effect of cell concentration on NHCtp was measured as %DIF from control. The analytes monitored in the described assays are similar in terms of their mass to charge ratios as well as their structural characteristics. Therefore, chromatographic and mass spectrometric conditions were assessed to optimize for separation, detection, and quantification. For analytes in PBMC lysate, several C18 and HILIC columns were tested without success prior to evaluation of the Scherzo SM-C18 column. Mobile phases evaluated varied in base concentrations; optimal separation and ionization was observed by using 50 mM ammonium formate: 5 mM ammonium hydroxide (MPA) and 80 mM ammonium formate: 8 mM ammonium hydroxide in [80:20] water: acetonitrile (MPB). This combination, with a gradient elution to 50% MPB, resulted in reproducible separation and elution for each analyte. Representative chromatograms of NHC isolated from plasma and NHCtp isolated from PBMC lysates at the LLOQ, along with their internal standards, are presented in Figure 2 . Intra-and inter-assay precision and accuracy of plasma NHC and PBMC NHCtp were assessed at LLOQ, low, mid, and high QC concentrations. Across the analytical measuring range of the assay, intraassay precision and accuracy ranged from 1.73 to 5.71% and -6.27 to -3.23% for plasma NHC and 2.72 to 7.71% and -8.83 to 8.69% for PBMC NHCtp, respectively. Across three (PBMC lysate) or four (plasma) independent runs, inter-assay precision and accuracy ranged from 3.43 to 6.40% and -6.37 to -5.22% for plasma NHC and 1.94 to 11.8% and -11.2 to 8.77% for PBMC NHCtp, respectively. Precision and accuracy results were within FDA bioanalytical recommended thresholds; a summary of intra-and interassay precision and accuracy is provided in Table 1 . Calibration curves were generated using weighted 1/x 2 quadratic (plasma) or linear (PBMC lysate) regression of analyte-to-internal peak area ratios. The analytical measuring ranges of the assays were 1-5000 ng/mL and 1-1500 pmol/sample for plasma NHC and PBMC NHCtp, respectively. Representative calibration curves for NHC in human plasma and NHCtp in PBMC lysate are illustrated in Supplemental Figure 1 . Dilution studies were performed both within and above the analytical measuring range of the assays to characterize the ability to analyze samples that are volume-limited or that exceed each assay's ULOQ. For partial volume analyses, %CVs and %DEVs ranged from 2.12 to 4.05% and -5.43 to -2.25% for plasma NHC, and 1.24 to 3.45% and -3.39 to 6.01% for PBMC NHCtp. Dilution of samples above the ULOQ up to 500-fold (plasma) and 50-fold (PBMC) also met acceptance criteria; %CVs and %DEVs were ≤2.60% and ≤±5.11% for plasma NHC and ≤4.15% and ≤±5.60% for PBMC NHCtp. Minimal carryover was observed for all analytes across both specimen sources; following four ULOQ injections, peak areas were <20% of the LLOQ signal, indicating negligible carryover within the analytical measuring range of the assay. Analyte stability for both the human plasma and PBMC assays was assessed under a variety of conditions, including in-matrix, post-preparative, freeze-thaw, and long-term storage. Whole blood stability was also performed for the plasma assay. Stability was assessed by comparing treated and freshly prepared or thawed QC samples. In human plasma, NHC demonstrated acceptable room temperature stability for 24 hours (%DIF: ≤±12.4%), but a %DIF was observed ranging from -7.95 to 19.9% at 48 hours, exceeding acceptability thresholds. NHC was also unstable in whole blood when stored at room temperature for 2-24 hours (%DIF: -70.1 to 1.12%); however, NHC is stable in whole blood when stored on ice for up to 4 hours (%DIF: -2.58 to -0.88%). NHC in plasma was stable for up to 3 freeze/thaw cycles, with a %DIF ranging from -3.58 to 1.27%. Further, NHC was stable in extract matrix (0.1% formic acid) and exhibited reinjection stability at 4-8°C for up to 72 hours, demonstrating %DIF of 0.631 to 1.09% and %DEV of -7.41 to -4.68%, respectively. Lastly, long-term stability assessment of NHC in plasma at ≤ -70°C demonstrated stability for up to 260 days, with %DEV ranging from -8.03% to -6.77%. NHCtp in PBMC exhibited acceptable stability under a number of conditions. The anabolite is stable in PBMC lysate at room temperature for up to 77 hours, with %DIF ranging from -2.44% to 0.871% (NHCtp). NHCtp is stable for up to 3 freeze/thaw cycles, with %DIF ranging from -5.06 to -0.391%. NHCtp also exhibited stability in extract matrix (water) for up to 137 hours when stored between 2-8°C, with %DIF ranging from -4.11 to 3.23% and demonstrated re-injection stability for 52 hours, with %DEV ranging from -9.17 to 9.74. Lastly, long-term stability assessments show that NHCtp is stable in PBMC lysate at ≤ -70°C for up to 148 days, with %DEV ranging from -6.21% to 5.79%. A summary of stability studies is included in Table 2 . Assay selectivity was evaluated by analyzing 6 blank lots of plasma and PBMC lysate. Representative chromatograms for NHC and NHCtp at each assay's LLOQ are overlaid with chromatograms of blank matrix ( Figure 3 ). Peak areas for all analytes in both specimen types were acceptable. Matrix effects were assessed quantitatively by comparing average peak areas of unextracted, postextracted, and pre-extracted (plasma assay only) materials. An average of 29.2% ion suppression was observed for NHC; however, relative matrix effects were negligible as there was <2% difference in matrix effects between NHC and NHC-IS; this was recapitulated when drug and IS were compared for recovery and processing efficiencies. For the PBMC lysate assay, a surrogate assessment of recovery for the Matuszewski method demonstrated recoveries of 101% for NHCtp. Significant ion suppression was observed for NHCtp in PBMC lysate; % matrix effects ranged from 35.6% to 86.3% for NHCtp. Increased NHCtp ion suppression was observed at higher drug concentrations. However, relative matrix effects were comparable between intracellular molecule and their respective internal standards, demonstrating that quantification using the peak area ratio corrects for any sample-specific matrix effect. Table 3 summarizes plasma NHC and PBMC NHCtp matrix effects, recovery efficiency, and processing efficiency, as applicable. PBMC concentrations of 0.2, 2, 10, and 20 x 10 6 cells/mL were spiked with NHCtp for recovery comparison. %DIF from the control (2 x 10 6 cells/mL) ranged from -2.98 to 10.7% (data not shown). Additionally, the 20 x 10 6 cells/mL condition produced chromatographic peak broadening (Supplemental Figure 2 ). In this report, we detail the development and validation of novel bioanalytical assays for the quantification of the antiviral NHC and its intracellular bioactive anabolite. LC-MS/MS assays for the quantification of NHC in human plasma and intracellular NHCtp in PBMC lysate were validated in accordance with FDA bioanalytical guidelines; assays met all analytical acceptance characteristics for use in clinical trials. Of particular note, the methods utilize low sample volumes, have efficient specimen preparation workflows, and have short run times. Additionally, we also validated the measurement of NHC in PBMC (data not shown). However, as NHC may freely diffuse from PBMC during cellular isolation and processing, while intracellular NHC is monitored, it is not reported. Two distinct methods were used for the quantification of NHC in human plasma and NHCtp in PBMC. This was attributed to an inability to achieve reproducible separation, elution, and quantification of NHCtp using the mobile phase system and analytical column employed for NHC in plasma. In order to achieve optimal NHCtp separation and elution, the Scherzo SM-C18 octodecyl silica-based column with anion and cation ligands was required; further, separation was achieved using a mobile phase system at a pH of 8.6. While this system would be amenable for NHC quantification, we elected to use a more commonly available reversed phase column and operate in positive ionization mode for NHC measurements in human plasma. NHC is administered as the pro-drug molnupiravir and is currently in phase 2/3 clinical trials for the treatment of patients with symptomatic COVID-19. Consequently, the availability of methods to measure primary systemic and bioactive forms of molnupiravir, plasma NHC and intracellular NHCtp, respectively, will aid in characterizing therapeutic efficacy and drug pharmacokineticspharmacodynamics. Based on recent findings from a phase 1, first in-human, dose-escalation study, NHC geometric mean maximum concentrations (C max ) ranged from 223 ng/mL to 6350 ng/mL in participants treated with a single dose of 50 mg to 1600 mg molnupiravir, respectively [4] . The analytical measuring range of the described plasma NHC assay (1-5000 ng/mL) is sufficient to characterize NHC over the evaluated range of administered doses. Of note, we did not develop a bioanalytical assay for molnupiravir quantification, as it is rapidly converted to NHC in vivo. Based on work by Painter et al., molnupiravir was only quantifiable in participants receiving higher doses of molnupiravir, and was not measurable beyond 1.5 h post-drug administration [4] . While the human plasma NHC assay met all acceptance criteria, we did characterize important preanalytical considerations required for specimen collection and processing. NHC is unstable in whole blood. Incubation of NHC-spiked whole blood from 2 to 24 hours demonstrated a significant negative bias of -21.5% as early as 2 hours. However, placement of whole blood on ice mitigated the loss of NHC. NHC also exhibited limited stability in plasma; 24 hours plasma stability of NHC when maintained at room temperature was acceptable, but storage at 48 hours resulted in a mean negative bias of -19.2% across the measuring range of the assay. These important pre-analytical observations should be considered during sample collection, and specimen processing should be expedited in order to ensure accurate results. The LC-MS/MS assay developed and validated NHCtp quantitation in PBMC mitigated the need for enzymatic dephosphorylation of negatively charged NHCtp. This is distinct from other antiviral anabolite methods, which enzymatically convert the anabolite to the parent molecule for quantification; this approach requires significant sample manipulation [16] . NHCtp is eluted quickly; this is likely attributed to the highly polar nature of the compound; while additional efforts were made to increase anabolite retention on the column, the validated method provided the required responses for reproducible quantification. In this method, direct anabolite separation and mass spectrometric detection was achieved via the use of a basic mobile phase system at pH 8.6, and ion monitoring in negative ionization mode. The basic pH used in the mobile phase system limits the number of samples and injections that can be analyzed on a column. During the validation of the assay, we observed that each column accommodated approximately 600 injections. This may be a consideration for studies in which a large volume of laboratory testing is required. Calibration standards and QCs for NHCtp PBMC assay were assigned as pmol/sample. As the method is designed to quantify intracellular concentrations and the number of isolated PBMC may vary both within and between individuals, results should be normalized to cell count for appropriate interpretation. We observed chromatographic changes in NHC and NHCtp, including peak broadening at cell concentrations exceeding 10 x 10 6 cells/mL (Supplemental Figure 2 ). This may be attributed to the one-step sample preparation and an increased density of cellular material introduced into the column. Cell counts should be taken into consideration during sample analysis. To date, there are no published reports of NHCtp from human PBMC; however in vitro studies show efficient intracellular conversion of NHC to NHCtp in several cell lines [17] . In HepG2 cells exposed to 20 µM NHC, peak NHCtp concentrations were observed 6 h post-treatment, with maximum concentrations of 733 pmol/10 6 cells. These data suggest that our intracellular NHCtp assay is sufficiently sensitive to measure NHCtp in human PBMC [17] . While we report the development and validation of sensitive and reproducible assays for the quantification of NHC in human plasma and NHCtp in PBMC, there are limitations. Chiefly, given the novelty of the compound as an investigational COVID-19 treatment, we are unable to describe drug pharmacokinetics in this report. However, the analytical measuring ranges of the assays are appropriate for the molnupiravir doses under evaluation. The PBMC method described is currently being applied to several phase 2/3 clinical trials to evaluate intracellular anabolite concentrations in patients with COVID-19; those results will be discussed in future reports. Additionally, stability challenges for NHCtp in PBMC lysates were evaluated post-lysis in 70% methanol; it is noted that continued metabolism may occur post-collection. In order to ensure accurate NHCtp measurements, it is recommended that samples are processed and lysed rapidly (typically within 60 minutes of collection). Lastly, while anabolite assessments in PBMC may provide additional information on molnupiravir efficacy, the overall relevance of NHCtp concentrations in PBMC as opposed to target cells and tissues important in SARS-CoV-2 pathogenesis is not known. There may be a future need to develop and validate NHCtp methods in other cellular populations or tissues. We have described sensitive and reproducible bioanalytical assays that facilitate the rapid quantification of NHC in plasma and NHCtp in PBMC. We characterized all validation parameters for drug quantification, and detailed important pre-analytical considerations required for accurate NHC and intracellular anabolite measurements. The described assay will be applied to clinical studies to better understand PK-PD relationships of molnupiravir in the treatment of COVID-19. An interactive web-based dashboard to track COVID-19 in real time The Natural History, Pathobiology, and Clinical Manifestations of SARS-CoV-2 Infections Food & Drug Administration Human Safety, Tolerability, and Pharmacokinetics of Molnupiravir, a Novel Broad-Spectrum Oral Antiviral Agent with Activity Against SARS-CoV-2 Reduction in infectious SARS-CoV-2 in treatment study of COVID-19 with molnupiravir Characterization of orally efficacious influenza drug with high resistance barrier in ferrets and human airway epithelia Identification of a new ribonucleoside inhibitor of ebola virus replication Small-Molecule Antiviral β-D-N4-Hydroxycytidine Inhibits a Proofreading-Intact Coronavirus with a High Genetic Barrier to Resistance β-D-N 4 -Hydroxycytidine Is a Potent Antialphavirus Compound That Induces a High Level of Mutations in the Viral Genome The prophylactic and therapeutic activity of a broadly active ribonucleoside analog in a murine model of intranasal venezuelan equine encephalitis virus infection An orally bioavailable broad-spectrum antiviral inhibits SARS-CoV-2 and multiple endemic, epidemic and bat coronavirus SARS-CoV-2 infection is effectively treated and prevented by EIDD-2801 Orally efficacious broad-spectrum ribonucleoside analog inhibitor of influenza and respiratory synctial viruses Guidance for Industry: Bioanalytical Method Validation Matrix Effect in Quantitative LC/MS/MS Analyses of Biological Fluids: A Method for Determination of Finasteride in Human Plasma at Picogram Per Milliliter Concentrations Liquid chromatography-tandem mass spectrometric determination of tenofovir-diphosphate in human peripheral blood mononuclear cells Analysis of the potential for N4-hydroxycytidine to inhibit mitochondrial replication and function .2 x 10 6 cells/mL, (B) 2x 10 6 cells/mL, and (C) 20 x 10 6 cells/mL. Development and Validation of Assays for the Quantification of β-D-N 4 -hydroxycytidine in Human Plasma and β-D-N 4 -hydroxycytidine-Triphosphate Peripheral Blood Mononuclear Cells Lysates Teresa L. Parsons 1 , Lindsay A. Kryszak 1 , and Mark A. Marzinke 1,2* Conflicts of Interest MAM has received research support from Ridgeback Biotherapeutics and Merck &Co Development and Validation of Assays for the Quantification of β-D-N 4 -hydroxycytidine in Human Plasma and β-D-N 4 -hydroxycytidine-Triphosphate Peripheral Blood Mononuclear Cells Lysates Teresa L. Parsons 1 , Lindsay A. Kryszak 1 , and Mark A. Marzinke 1,2* CRedIT authorship contribution statement: Teresa Parsons: Conceptualization; Validation; Data Curation Formal Analysis; Writing-original draft; Writing -review & editing Mark Marzinke: Conceptualization; Formal Analysis; Writing-original draft; Writing -review & editing Development and Validation of Assays for the Quantification of β-D-N 4 -hydroxycytidine in Human Plasma and β-D-N 4 -hydroxycytidine-Triphosphate in Peripheral Blood Mononuclear Cell Lysates Teresa L MAM has received research support from Ridgeback Biotherapeutics and Merck &Co, Inc. in support of molnupiravir-focused clinical trials.