key: cord-0707412-atsj4q02 authors: Chen, Cuicui; Lai, Hongrui; Liang, Huankun; He, Ying; Guo, Guiling; Li, Laiqing title: A New Method for Detection African Swine Fever Virus: Time-resolved Fluorescence Immunoassay date: 2021-06-01 journal: J Fluoresc DOI: 10.1007/s10895-021-02754-9 sha: b1d46c6b1f03ff4e8e484e59f60d6c78f44be628 doc_id: 707412 cord_uid: atsj4q02 African swine fever (ASF) has severely influenced the swine industry of the whole world. Fast and accurate African swine fever virus (ASFV) antigen detection is very important for ASF prevention. This study aims to establish a new detection method for detection ASFV antigen using time-resolved fluorescence immunoassay (TRFIA) in the nose and mouth discharge. A double antibody sandwich TRFIA method was optimized and established. Recombinant P30 recombinant antigen was captured by its antibodies immobilized on 96-well plate, and then banded together with another detection antibodies labeled with Europium(III) (Eu(3+)) chelates, finally time-resolved analyzer measured the fluorescence intensity. The performance of this TRFIA (sensitivity, specificity and accuracy) was evaluated using the clinical samples and compared with the nucleic acid testing method. The sensitivity of this TRFIA was 0.015 ng/mL (dynamic range 0.24–500 ng/mL) with high specificity. The recovery ranged from 92.00 to 103.62 %, the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %. Additionally, the cutoff value was 0.016. TRFIA took only 45 min to generate results, and its detection capability comparable to the nucleic acid detection. This study developed a TRFIA method that could be used for qualitative/quantitative detection of ASFV antigen in pigs nasal discharge, which has high sensitivity, specificity and accuracy. This TRFIA provides a new method for rapidly screening ASFV infection in pigs industry. African swine fever (ASF) is a viral hemorrhagic disease of pigs with mortality rates approaching 100 %, it is caused by a large DNA virus, African swine fever virus (ASFV) [1, 2] . ASF has caused major economic losses, limited pig industry and even threatened food security in affected countries. ASF has erupted and spread in Poland, Lithuania, China, Latvia, Belarus, USA and the Russian Federation etc. [3, 4] . Unfortunately, there is currently no effective antiviral drug or vaccine against ASFV [5] . Stamping out and movement control are the mainly control measures. Currently, the diagnostic methods for ASFV include nucleic acid detection, ASFV antigen detection and ASFV antibody detection (ELISA method), and establishment of new ASFV diagnostic technology is urgently needed [6, 7] . Time-resolved fluorescence immunoassay (TRFIA) is a novel detection technique using the unique lanthanide fluorescence properties, which can offer higher sensitivity, lower matrix interference and enlarge dynamic range than ELISA [8] [9] [10] . At present, TRFIA has been used in the diagnosis and screening of various viral infectious diseases of humans and animals [11, 12] . However, TRFIA has not yet been used in ASF screening. In this present study, we have optimized and established a double-antibody sandwich TRFIA method for detection of ASFV antigen. Compared with commercial ELISA kits, the detection performance of TRFIA is equivalent. This TRFIA provide a new method for sensitive, accurate and specific detection of ASFV. Recombinant P30 recombinant antigen (Escherichia coli), anti-P30 paired monoclonal antibodies of ASFV were prepared by Guangzhou Youdi Biotechnology Co., Ltd. 15 clinical nasal discharge samples with ASFV positive, and 110 healthy ral/nasopharyngeal swab samples came from South China Agricultural University. All samples were stored at -80 . Europium(III) (Eu 3+ ) labeling kit was purchased from PerkinElmer (Norwalk, USA). Sephadex G50 column was purchased from Amersham Pharmacia Biotech (Piscataway, NJ, USA). The buffers used in this study are all self-prepared using the routine laboratory reagents. Anti-P30 coating monoclonal antibodies were diluted into different concentrations (1 µg/mL, 2 µg/mL, 5 µg/mL, 10 µg/ mL) and added into the 96-well plates. Coated the plates at 37 for 2 h, and then blocked the plates with 200 µL/well blocking buffer (50 mmol/L, pH 7.4 PBS supplemented with 3 % BSA) at 37 for 1 h. Then, removed the blocking buffer and dried in vacuum, and finally stored the 96-well plates at -4 . Using different concentrations of anti-P30 coating monoclonal antibodies to optimize antibody coating concentration. According to the protocol provided by the Eu 3+ labeling kit, anti-P30 detection monoclonal antibodies was labeled with Eu 3+ -chelates. Briefly, washed the 1 mg detection antibodies with labeling buffer (2 mg/mL), and then added into 50, 100 or 200 µg Eu 3+ -chelates. Gently shaken the mixture for 24 h at -4 , and then purified the Eu 3+ -labeled detection antibodies using a Sephadex G50 column. Finally, the Eu 3+ -labeled detection antibodies purified were stored at -20 . Optimized assay procedure using the one-step procedure, including the volume of Eu 3+ -labeled detection antibodies and enhancement solution, and the immunoreaction time. Briefly, standards, samples and Eu 3+ -labeled detection antibodies were added into the coated 96-well plates, and then incubated at room temperature. After washing the wells, added the enhancement solution into the wells, and shaken gently for a few minutes. Finally, time-resolved analyzer (PerkinElmer, Auto 1420, Waltham, MA, USA) measured the fluorescence. Scheme of the present TRFIA was shown in Fig. 1 . The standard curve was established using serial dilutions of P30 antigen (0, 0.01, 0.1, 1, 10, 100 and 500 ng/mL). The Log function values of P30 antigen were plotted as X axis, and the Log function value of their fluorescence as the Y axis, performed a linear fit and draw the standard curve. The limit of the blank (LOB) was defined as the mean of the blank assayed in 20 independent measurements. The limit of detection (LOD) was determined by adding two standard deviations (SD) to the LOB, that means LOD = LOB + 2*SD [13] . High concentrations of transmissible gastroenteritis virus (TGEV), porcine respiratory coronavirus (PRCV), porcine hemagglutinating encephalomyelitis virus (PHEV), swine influenza H1N1 virus and porcine circovirus (PCV) were selected for specificity assay. By adding the known concentrations of P30 antigen (high, medium, and low concentration respectively) into the nasal discharge samples of healthy pigs, we evaluated the accuracy and recovery of this TRFIA method. Performed six independent experiments and calculated the mean and their SD. The recovery, and the CVs of the intra-assay and interassay This TRFIA method was used to detect the 110 nasal discharge samples of the healthy pigs. Recorded the fluorescence values of swab samples (Fs) and blank control (background values, Fc), and calculate their antigen concentration according to the standard curves. SPSS 17.0 was used for data statistical analysis. If the values of antigen concentration belongs to the normal distribution, the normal distribution method is used to calculate the reference interval range, and the 95 % reference interval range is calculated by the following formula: cut off = mean + 1.96SD. A double-antibody sandwich TRFIA method was developed under the following conditions: coating amount of anti-P30 coating antibodies: 2 µg/mL, 100µL/well; optimized labeling procedure: 1 mg detection antibodies (2 mg/mL) + 100 µg Eu 3+ -chelates; 100 µL/well Eu 3+ -labeled detection antibodies, 200µL/well enhancement solution, and the immunoreaction time was 45 min (Fig. 2) . In a word, the optimized assay procedure is: 20 µL samples or standards, 100 µL/well Eu 3+ -labeled detection antibodies were added into the coated 96-well plates, and then incubated for 45 min at room temperature. After washed the w ells 5 times, a dded 200 µL/well enhancement solution into the wells, and shaken gently for 2 min. Finally, time-resolved analyzer measured the fluorescence. Standard curve determinations were carried out using linear regression and Log-Log regression. For the standard curve depicted in Fig. 3 , The best-fit calibration was depicted in Fig. 3 by the following equation: LogY = 0.2019×LogX + 2.9888 (R 2 = 0.9903). Sensitivity assay indicates the LOD of this TRFIA was 0.015 ng/mL, and the dynamic range ranged from 0.24 to 500 ng/mL. This TRFIA detected the 5 interferents with high concentrations (TGEV, PRCV, PHEV, H1N1 and PCV), and their results are shown in Table 1 . The cross-reactivity was very low, ranging from 0.18 to 0.23 %, which means this TRFIA method had high specificity for ASFV P30 antigen. As presented in Table 2 , the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %. All CVs were less than 15 %, which indicates that this TRFIA assay has high accuracy. Additionally, the recovery was between 92.00 and 103.62 %. The recovery results indicated that this TRFIA method was free from interferents in matrix samples. After performing a normality test with SPSS 17.0, the concentration values were normally distributed, so that the one-sided upper limit of the 95 % reference interval range was performed for the calculation. For 110 nasal discharge samples of the healthy pigs, the mean concentration value was 0.011, SD was 0.0026, the cutoff value was 0.016 (cut off = mean + 1.96SD), which meant that when antigen concentration was greater than 0.016, the sample may be ASFV positive. To confirm the diagnostic accuracy of our assay, we used it to synchronously test 15 clinical nasal discharge samples with ASFV positive and 110 nasal discharge samples of the healthy pigs. As shown in Table 3 , the χ2 test showed that the P-value of the McNemar test was 1.0, and the value obtained with the kappa test was 0.924 (P < 0.001), which means there was no statistically significant difference between our developed TRFIA method and the nucleic acid testing method. ELISA specific for ASFV antigen/antibody are most commonly used in the clinical diagnosis of ASF infection [14] [15] [16] . But most of them are qualitative and with narrow detection ranges. Although the PCR method is the gold standard for various types of virus detection, only a few PCR-based ASF diagnostic assays have been previously described for detection and identification of ASFV [17, 18] . This may be because the PCR method requires relatively high technical personnel and equipment. At present, various new methods have been established and applied in ASF screening. LAMP is an alternative to traditional PCR, which requires a shorter reaction time, higher specificity and has a lower cost [19] . James et al. developed a loopmediated isothermal amplification (LAMP) assay, and it is a simple-to-use and inexpensive molecular assay format for ASF diagnosis. There was good concordance between the LAMP assay and real-time PCR in clinical samples [20] . TRFIA is a sophisticated detection technique, and has been widely used in the detection of multiple viruses or their antigens [21, 22] . Compared with ELISA, TRFIA has higher sensitivity and wider measurement range. Schröder and Kuhlmann found that the use of a TRFIA significantly improved the quantitative detection of tetanus antitoxin over that of the ELISA technique, and the wide measurement range of TRFIA enabled fast examination of large numbers of serum samples without the need for repetition [23] . In this study, a novel TRFIA methodology was developed for the quantitative determination of ASFV antigen in pigs nasal discharge. The comparison experiment found its detection performance is equivalent with LAMP-based kits (Chinese Academy of Inspection and Quarantine, Beijing, China, No. 11 new veterinary drugs). The result shows that TRFIA is a promising detection method, which has better performance than ELISA and real-time PCR. In this study, we developed a high sensitivity, specificity, and accuracy TRFIA using Eu 3+ chelates. The assay was based on an double-antibody sandwich immunoassay format, and performed in 96-well plates. The sensitivity of this TRFIA is 0.015 ng/mL (dynamic range 0.24-500 ng/mL). There is very low cross-reaction with 5 interferents. The recovery ranged from 92.00 to 103.62 %, the inter-assay CVs ranged from 5.50 to 11.96 %, and the intra-assay CVs was between 5.20 and 10.53 %, which means this TRFIA has high accuracy. Additionally, we calculated the cutoff values using 110 nasal discharge samples of the healthy pigs. When antigen concentration ≥ 0.016 ng/mL, the sample (pig) may be ASFV positive. Compared with the nucleic acid method, χ2 test showed the detection performance of TRFIA is equivalent. Importantly, the main advantage of this TRFIA is in quantitative detection (not just qualitative detection). The cutoff values provide the basis for qualitative screening, and the drawn standard curve realizes quantitative detection for ASFV. In conclusion, we developed a TRFIA method that could be used for qualitative/quantitative detection of ASFV antigen in pigs nasal discharge, which has high sensitivity, specificity and accuracy. TRFIA takes only 45 min to generate results, and its detection capability comparable to the nucleic acid detection. Therefore, the kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease. Data Availability The data used and/or analysed in the current study are given in the submitted article. Code Availability No applicable. Conflicts of Interest The authors declared that they have no conflicts of interest. Ethics Approval No applicable. African swine fever: how can global spread be prevented African swine fever virus infection disrupts centrosome assembly and function Epidemiology of African Swine Fever in Poland since the detection of the first case Molecular characterization of African swine fever virus, China Prediction of antiviral drugs against African swine fever viruses based on protein-protein interaction analysis African swine fever diagnosis adapted to tropical conditions by the use of dried-blood filter papers Highly sensitive PCR assay for routine diagnosis of African swine fever virus in clinical samples Lanthanide complex-based fluorescence label for time-resolved fluorescence bioassay Total error profiling of a proinsulin time-resolved fluorescence immunoassay Development of a time-resolved fluorescence immunoassay for Epstein-Barr virus nuclear antigen 1-immunoglobulin A in human serum Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay Determination of parvovirus antigen in the vaccine using time-resolved fluorescence immunoassay A time-resolved fluoroimmunoassay to assay the rabies virus glycoprotein: application for estimation of human rabies vaccine potency Indirect sandwich ELISA for antigen detection of African swine fever virus: comparison of polyclonal and monoclonal antibodies Diagnostic specificity of the African swine fever virus antibody detection enzymelinked immunosorbent assay in feral and domestic pigs in the United States Recombinant antigen targets for serodiagnosis of African swine fever Development of an internal control for the detection of the African swine fever virus by PCR Molecular diagnosis of African Swine Fever by a new real-time PCR using universal probe library Evaluation and comparison of Loop-mediated Isothermal Amplification (LAMP) Detection of African swine fever virus by loopmediated isothermal amplification Detection of hepatitis B virus PreS1 antigen using a time-resolved fluoroimmunoassay Dual-labeled time-resolved immunofluorometric assay for the simultaneous quantitative detection of hepatitis B virus antigens in human serum Detection of tetanus antitoxin using Eu(3+)-labeled anti-human immunoglobulin G monoclonal antibodies in a time-resolved fluorescence immunoassay Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations