key: cord-0707098-azlajt0m authors: Tsui, Ban C.H.; Pan, Stephanie title: Are aerosol-generating procedures safer in an airborne infection isolation room or operating room? date: 2020-09-16 journal: Br J Anaesth DOI: 10.1016/j.bja.2020.09.011 sha: ff6788285401a235b64584adff8b513575659771 doc_id: 707098 cord_uid: azlajt0m nan Editor -One of the most important considerations for healthcare worker in the midst of the coronavirus disease 2019 (COVID-19) pandemic is the location in which aerosol-generating procedures are performed for patients with suspected or known COVID-19. Aerosol-generating procedures include ventilation through a facemask, tracheal intubation, and tracheal extubation. For nonsurgical patients, a negative pressure airborne infection isolation room is the preferred location for performing aerosol-generating procedures because the negative pressure reduces droplet and aerosol transmission from within the isolation room to the environment outside. 1 For surgical patients with suspected or known COVID-19, the American Society of Anesthesiologists (ASA) 1 also recommends "perform[ing] procedures in an airborne infection isolation room rather than in an operating room." Some readers may interpret the ASA recommendation to imply increased safety when performing aerosol-generating procedures in an airborne infection isolation room as compared to an operating room. However, there is limited evidence regarding the safety of healthcare workers within these two locations in terms of aerosol exposure and exposure time. Using an airway manikin model setup 2 , we compared aerosol exposure and time by measuring particle concentrations during and after saline nebulization in a positive pressure operating room and a negative pressure airborne infection isolation room. We simulated aerosol exposure during intubation using a nebulizer (CareFusion Airlife Misty Max 10 Disposable Nebulizer) to nebulize saline into aerosol droplets with a median size of 1.6 μm into the trachea of an airway manikin placed in the centre of a room. 2 The aerosolized droplets generated are comparable in diameter to aerosolized COVID-19 droplets (which have two size ranges: 0.25 to 1 μm and > 2.5 μm). 3 Using a particle counter (Digital PM2.5 Air J o u r n a l P r e -p r o o f Quality detector, Geekcreit, Banggood, Guangzhou, China), particle concentrations (µg m -3 ) of particulate matter with diameter < 1 μm (PM 1 ), < 2.5 μm (PM 2.5 ) and < 10 μm (PM 10 ) were measured. One particle counter was placed 30 cm directly above the manikin to simulate the proceduralist's location and exposure during tracheal intubation with direct laryngoscopy 2 , and the other particle counter was placed immediately outside the closed door to detect aerosol leakage outside the room. During pilot experiments, particle concentrations returned to baseline These findings can be partially explained by the different room ventilation system designs for the operating room and the airborne infection isolation room. While the number of air changes per hour for operating rooms and airborne infection isolation rooms vary between hospitals and even within the same hospital, the minimum required air changes per hour for an operating room in the US is 15 as compared to 12 for an airborne infection isolation room as mandated by the 2018 Facilities Guideline Institute. 4 For this simulation, aerosol particle concentrations were measured in a positive pressure operating room with air changes per hour of 27 and a negative pressure airborne infection isolation room with air changes of 12 per hour. The reduced air changes per hour in an airborne infection isolation room can also result in increased recirculation of aerosols, incomplete air mixing, and incomplete room air exchange. 5 In addition to prolonged aerosol exposure times, performance of aerosol-generating procedures in remote airborne infection isolation rooms have well recognized associated risks (i.e. unfamiliar equipment, limited resuscitation resources, crowded patient access, and increased hazards during transport to the operating room). 6 The main reason for recommendations that aerosolgenerating procedures be performed in an airborne infection isolation room rather than in an operating room is to limit spread of viral aerosols outside the room, but there may be a greater risk of anaesthetists being exposed to viral aerosols when performed in an airborne infection isolation room than in the operating room. Prior to instituting any safety measures, clinicians and policy makers should objectively evaluate the dynamic behaviour of aerosols within their own operating room and airborne infection isolation room ventilation systems to maximize safety for their healthcare workers. The authors have no conflicts of interest to declare. COVID-19 Information for Health Care professionals: recommendations. American Society of Anesthesiologists Distanced-based dynamic behaviour of aerosol particles during aerosol-generating medical procedures Guideline for Environmental Infection Control in Health Facilities. (Table B.2 Ventilation rquirements for areas affecting patient care in hosptals and outpatient facilities). Centers for Diesease Control and Prevention (CDC) Removal of exhaled particles by ventilation and deposition in a multibed airborne infection isolation room. Indoor Air The risk and safety of anesthesia at remote locations: the US closed claims analysis