key: cord-0704769-qt9bvysr authors: Schmidt, Katja G.; Harrer, Ellen G.; Tascilar, Koray; Kübel, Sabrina; El Kenz, Boutaina; Hartmann, Fabian; Simon, David; Schett, Georg; Nganou-Makamdop, Krystelle; Harrer, Thomas title: Characterization of Serum and Mucosal SARS-CoV-2-Antibodies in HIV-1-Infected Subjects after BNT162b2 mRNA Vaccination or SARS-CoV-2 Infection date: 2022-03-21 journal: Viruses DOI: 10.3390/v14030651 sha: 2ad25e52e720ddd5722f31a9603ec1c15fbab1d2 doc_id: 704769 cord_uid: qt9bvysr Only limited data are available regarding the immunogenicity of the BNT162b2 mRNA vaccine in HIV-1(+) patients. Therefore, we investigated the humoral immune response after BNT162b2-mRNA vaccination or SARS-CoV-2 infection in HIV-1(+) patients on antiretroviral therapy compared to HIV-1-uninfected subjects. Serum and saliva samples were analysed by SARS-CoV-2 spike-specific IgG and IgA ELISAs and a surrogate neutralization assay. While all subjects developed anti-spike IgG and IgA and neutralizing antibodies in serum after two doses of BNT162b2 mRNA vaccine, the HIV-1(+) subjects displayed significantly lower neutralizing capacity and anti-spike IgA in serum compared to HIV-1-uninfected subjects. Serum levels of anti-spike IgG and neutralizing activity were significantly higher in vaccinees compared to SARS-CoV-2 convalescents irrespective of HIV-1 status. Among SARS-CoV-2 convalescents, there was no significant difference in spike-specific antibody response between HIV-1(+) and uninfected subjects. In saliva, anti-spike IgG and IgA antibodies were detected both in vaccinees and convalescents, albeit at lower frequencies compared to the serum and only rarely with detectable neutralizing activity. In summary, our study demonstrates that the BNT162b2 mRNA vaccine induces SARS-CoV-2-specific antibodies in HIV-1-infected patients on antiretroviral therapy, however, lower vaccine induced neutralization activity indicates a lower functionality of the humoral vaccine response in HIV-1(+) patients. Current strategies to control the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic rely on the efficacy of SARS-CoV-2 vaccines. Indeed, in less than one year, several vaccines have been licensed after they had demonstrated high efficacy against development of COVID-19 [1] [2] [3] [4] . The first approved vaccine was BNT162b2 mRNA (Pfizer/BioNTech, COMIRNATY ® ), which is based on a new technology using a modified viral messenger ribonucleic acid (mRNA) encoding the spike (S) glycoprotein of SARS-CoV-2 [1] . Clinical studies in the general population showed a robust generation of SARS-CoV-2-specific antibodies by BNT162b2 mRNA but only limited data are available regarding the humoral immunity in immunocompromised patients [5] [6] [7] . Over the course of 5 to 10 years, HIV-1 induces a progressive immunodeficiency in most untreated infected patients, which is associated with a poor immune response to vaccination [8] . Modern combination antiretroviral therapy (cART) can suppress HIV-1 replication and improves both CD4 + T-cell counts and immunological competence in most compliant patients. Nevertheless, even cART-treated HIV-1-infected patients exhibit generally lower vaccine efficacy as seen for hepatitis B, influenza, and herpes zoster vaccines [9] [10] [11] . So far, our knowledge regarding SARS-CoV-2-specific immunity in HIV-1-infected subjects on cART remains limited. It has been shown by several groups that neutralizing antibodies play an important role in the control of SARS-CoV-2, both in humans (reviewed in [12] [13] [14] ) and in nonhuman primate models [15] . Therefore, we investigated the humoral immune response in cART-treated HIV-1-infected subjects and in HIV-1-uninfected subjects after SARS-CoV-2 infection or vaccination with BNT162b2 mRNA. Here, the SARS-CoV-2 spike-specific IgG and IgA antibody levels were measured in serum by ELISA, and the serum neutralizing activity against the S1/RBD domain of the SARS-CoV-2 spike protein was assessed using a surrogate neutralizing antibody assay. As the HIV-1 infection has a negative impact on mucosal immunity [16] , we also investigated the SARS-CoV-2 spike-specific IgA and IgG-antibodies and neutralizing activity in saliva. For this study, 82 HIV-1-infected subjects from the Erlangen HIV cohort and 77 HIV-1-uninfected subjects composed of hospital personnel and volunteers from a prospective SARS-CoV-2 seroprevalence study were recruited [17, 18] . Inclusion criteria for HIV-1infected patients were two vaccinations with BNT162b2 mRNA vaccine or past SARS-CoV-2-infection and stable antiretroviral therapy with a viral load of <100 copies/mL. Exclusion criteria were untreated HIV-1-infection, overt clinical disease, a viral load >100 copies/mL and immunosuppressive therapy at the time of sample collection or vaccination/SARS-CoV-2 infection. Inclusion criteria for the controls were two vaccinations with the BNT162b2 mRNA vaccine or past SARS-CoV-2-infection, and absence of HIV-1 infection. Exclusion criteria for healthy controls were overt clinical disease and immunosuppressive therapy at the time of sample collection or vaccination/SARS-CoV-2 infection. The prime-boost interval between two doses of 30µg of BNT162b2 mRNA vaccine ranged between 20 and 49 days. The HIV-1-infected subjects were on an effective antiretroviral therapy with a median viral load of <20 copies/mL (IQR: <20 to 20 copies/mL, range <20 to 60 copies/mL). The viral load was suppressed to <20 copies/mL in 51 of 82 subjects. Of the total 159 recruited subjects, 110 subjects were vaccinated with the BNT162b2 mRNA SARS-CoV-2 vaccine, of which 50 were HIV-1-infected and 60 were HIV-1-uninfected. A total of 43 of the 159 study participants had recovered from asymptomatic to severe COVD-19 infection, of which 26 were HIV-1-infected and 17 were HIV-1-uninfected. Six participants were HIV-1-infected SARS-CoV-2 seronegative subjects that did not receive any SARS-CoV-2 vaccination, did not display any respiratory symptoms at the time of sample collection (Mai 2021) and had no history of COVID-19, thus serving as SARS-CoV-2 non-immune controls. Characteristics of the study participants including gender distributions are summarized in Table 1 . Further detailed clinical data for individual subjects are presented in the Supplementary Table S1 . The study with analysis of virus specific immune responses was approved by the Ethics Committee of the Medical Faculty (Numbers 250_15B and 157_20 B). Blood and saliva were obtained after informed consent. Sera of the 110 BNT162b2 mRNA vaccinated subjects were collected 7-155 days after the second BNT162b2 mRNA vaccination (median of 37 days for HIV-1-infected and 26 days for HIV-1 uninfected). Saliva samples were collected from 34 vaccinated subjects 8-155 days after the second BNT162b2 mRNA vaccination (median of 17 days for HIV-1-infected and 38 days for HIV-1-uninfected). The sera from the 43 SARS-CoV-2 convalescent subjects were collected 7-240 days post PCR diagnosis of COVID-19 disease, as well as saliva samples from 21 convalescents 28-179 days after PCR diagnosis (median of 93 days for HIV-1infected and 104 days for HIV-1-uninfected). In the four asymptomatic seroconverters with no PCR result (#62, #113, #492 and #586), samples were obtained either 116 and 199 days after the first positive SARS-CoV-2 antibody test or at the first positive SARS-CoV-2 antibody test on day 38 and 264 after the last negative serological test, respectively. For processing of sera, samples underwent a coagulation period of at least 60 min at room temperature prior to centrifugation at 1900× g for 10 min at room temperature. All sera samples were stored at −20 • C until further use. The saliva samples were centrifuged at 11,000× g for 10 min at room temperature for mucus precipitation and the supernatant was stored at −20 • C until further use. The IgG antibodies against the SARS-CoV-2 spike protein were detected using a CE certified commercial enzyme-linked immunosorbent assay (ELISA, Euroimmun, Lübeck, Germany) [19] [20] [21] according to the manufacturer's protocol. Briefly, samples were diluted in sample buffer to a final dilution of 1:101 for sera and 1:10 for saliva samples. Per well, 100 µL of calibrator, controls and diluted samples were added in a pre-coated 96 well plate and incubated for 1 h at 37 • C. The wells were washed 3 times with 300 µL washing buffer before addition of 100 µL enzyme conjugate per well. After an incubation period of 30 min at 37 • C, wells were washed 3 times with 300 µL washing buffer. 100 µL substrate was added per well and incubated for 30 min at room temperature. The reaction was stopped with 100 µL stopping solution per well and the absorbance was measured using an ELISA reader (Tecan) at a wavelength of 450 nm with a reference wavelength of 620 nm. The IgG levels were calculated as ratios by dividing the extinction of the sample by that of the calibrator. A ratio of <0.8 was considered negative, a ratio of 0.8-1.1 as borderline and ≥1.1 as positive. The IgA antibodies against the SARS-CoV-2 Spike protein were detected using a CE certified commercial ELISA (Euroimmun [21] ) according to the manufacturer s protocol as stated for the IgG ELISA. The IgA levels were calculated as ratios by dividing the extinction of the sample by that of the calibrator. A ratio of <0.8 was considered negative, a ratio of 0.8-1.1 as borderline and ≥1.1 as positive. Neutralizing antibodies against the S1/RBD domain of the SARS-CoV-2 spike protein (Wuhan-Hu-1 isolate) were detected using a commercial ELISA (NeutraLISA, Euroimmun) according to the manufacturer's protocol. Briefly, 20× concentrated ACE2 substrate was diluted to 1× in ACE2 dilution buffer. The sera and saliva samples were then diluted 1:5 in the 1× ACE2 solution. For the 1:101 dilution of sera, the ACE2 substrate was diluted 1:24.75 in ACE2 dilution buffer prior to addition of sera. A total of 100 µL of diluted sample was added per well of a S1/RBD domain-pre-coated 96 well plate and incubated for 1 h at 37 • C. The wells were washed 3 times with 300 µL washing buffer before adding 100 µL enzyme conjugate per well. After an incubation period of 30 min at room temperature, wells were washed 3 times with 300 µL washing buffer. The 100 µL substrates were incubated per well for 15 min at room temperature. The reaction was stopped with 100 µL stopping solution and the absorbance was measured on an ELISA reader (Tecan, Männedorf, Switzerland) at a wavelength of 450 nm with a reference wavelength of 620 nm. The inhibition was calculated as following: % IH = 100% − extinction of sample ×100% extinction of blank (mean) An inhibition of <20% was considered negative, an inhibition between 20-35% as borderline and ≥35% as positive. Negative calculated values (<0%) were considered as 0% inhibition. To determine the protein concentration in saliva, samples were measured using a BCA assay (Pierce™ BCA Protein Assay Kit, Thermo Fisher Scientific, Waltham, MA, USA) according to the manufacturer's protocol. Briefly, saliva was diluted 1:10 in working reagent. The diluted saliva samples and the BSA standard were incubated in a 96 well microtiter plate at 37 • C for 1 h. After a cooling period to allow the samples to reach room temperature, the absorbance was measured at a wavelength of 560 nm on an ELISA reader. The concentration of the samples was calculated from the determined standard curve. To normalize the IgG and IgA saliva levels, the IgG or IgA ratio was divided by the protein concentration (µg/µL) of the respective sample. Participant characteristics are presented using appropriate summary statistics. As antibody responses are expected to be affected by age, gender, and time to sample acquisition after exposure to the infectious agent or completion of vaccination, we used linear regression to adjust for these confounders, where age and time variables were centred at the overall mean/median respectively. Model coefficients for the grouping variable, i.e., HIV, control, infected, and vaccinated, indicate the adjusted between-group mean differences and the model intercepts indicate the mean adjusted antibody level in the reference group. In the models for antibody levels between vaccinated groups, a term for median-centred duration between two vaccine doses was also included. All univariate statistical analyses were carried out using GraphPad Prism 9.0.2 (GraphPad Software, San Diego, CA, USA). Multivariate analysis was performed in R v. 4.0.1 software (R Foundation for Statistical Computing, Vienna, Austria). Two-sided p values < 0.05 were considered significant without multiplicity adjustment. For the analysis of the BNT162b2 mRNA induced SARS-CoV-2-specific humoral immune response, we first measured the serum levels of the anti-spike IgG antibodies in 50 vaccinated HIV-1-infected and 60 vaccinated HIV-1-uninfected subjects. After two BNT162b2 mRNA doses, all subjects developed SARS-CoV-2 spike-specific IgG antibodies (p < 0.0001). In a univariate analysis, the median spike-specific-IgG antibody level was lower in the HIV-1-infected subjects compared to HIV-1-uninfected subjects (p = 0.028, Figure 1a , Supplementary Table S2 ). tibody responses are expected to be affected by age, gender, and time to sample acquisition after exposure to the infectious agent or completion of vaccination, we used linear regression to adjust for these confounders, where age and time variables were centred at the overall mean/median respectively. Model coefficients for the grouping variable, i.e., HIV, control, infected, and vaccinated, indicate the adjusted between-group mean differences and the model intercepts indicate the mean adjusted antibody level in the reference group. In the models for antibody levels between vaccinated groups, a term for mediancentred duration between two vaccine doses was also included. All univariate statistical analyses were carried out using GraphPad Prism 9.0.2 (GraphPad Software, San Diego, CA, USA). Multivariate analysis was performed in R v. 4.0.1 software (R Foundation for Statistical Computing, Vienna, Austria). Two-sided p values < 0.05 were considered significant without multiplicity adjustment. For the analysis of the BNT162b2 mRNA induced SARS-CoV-2-specific humoral immune response, we first measured the serum levels of the anti-spike IgG antibodies in 50 vaccinated HIV-1-infected and 60 vaccinated HIV-1-uninfected subjects. After two BNT162b2 mRNA doses, all subjects developed SARS-CoV-2 spike-specific IgG antibodies (p < 0.0001). In a univariate analysis, the median spike-specific-IgG antibody level was lower in the HIV-1-infected subjects compared to HIV-1-uninfected subjects (p = 0.028, Figure 1a , Supplementary Table S2 ). Considering possible differences in the kinetics of antibody responses, we found a weak correlation between the serum IgG and IgA levels and time after the second vaccination in both HIV-1 infected and uninfected donors (Supplementary Figure S1f ,g). Therefore, we performed a multivariate linear regression analysis adjusting for age, gender, time after second vaccination and length of the prime-boost interval, which showed no significant difference in the serum spike-specific IgG levels between HIV-1-infected and uninfected persons (p = 0.394; Table 2 ). Comparison of these vaccine-induced anti-spike IgG levels to those induced after SARS-CoV-2 infection showed significantly higher spike-specific IgG levels in the serum of the BNT162b2 mRNA vaccinees compared to the COVID-19 convalescent subjects, irrespective of HIV status (p ≤ 0.0001, Figure 1a , Supplementary Table S2), even after adjustment for age, gender, time after second vaccination or time after infection (Table 3) . Among COVID-19 convalescent subjects, spike-specific IgG levels were not significantly different between the HIV-1-infected patients and the HIV-1-uninfected subjects (Figure 1a , Supplementary Table S2) . In addition to spike-specific IgG antibodies, we also measured spike-specific IgA antibodies in the serum of our study participants. The BNT162b2 mRNA vaccine was able to induce spike-specific IgA antibodies in all vaccinated subjects (p < 0.0001, Figure 1b) , albeit without significant difference between HIV-1-infected subjects and HIV-1-uninfected controls in a univariate analysis (Figure 1b, Supplementary Table S2 ). Multivariate linear regression analysis adjusting for gender, age, time after second vaccination and primeboost interval revealed that HIV-1 infection was associated with lower serum IgA-levels (p = 0.041, Table 4 ). Serum spike-specific IgA levels did not differ between vaccinees and COVID-19 convalescents. While univariate analysis of the spike-specific IgA antibody levels in serum indicated higher levels in HIV-1-uninfected BNT162b2 mRNA vaccinees compared to HIV-1-uninfected COVID-19 convalescent subjects (Figure 1b, Supplementary Table S2 ), Viruses 2022, 14, 651 7 of 18 multivariate analysis adjusting for age, gender, time after second vaccination and time after infection, respectively, showed no significant difference between these groups (Table 5) . Among COVID-19 convalescent subjects, the spike-specific IgA levels did not differ between the HIV-1-infected subjects and the HIV-1-uninfected controls. To estimate the relative contribution of the spike-specific IgG and IgA antibodies to SARS-CoV-2 humoral immunity, we next performed paired comparisons of serum spikespecific IgG and IgA levels per participant in our study. Among vaccinated subjects, the spike-specific IgG levels were significantly higher than the spike-specific IgA levels in HIV-1-infected patients and HIV-1-uninfected donors (p < 0.0001; Figure 2 ). Among COVID-19 convalescent subjects, the serum spike-specific IgG and IgA levels were not significantly different in either the HIV-1-infected (p = 0.731) or the HIV-1-uninfected (p = 0.669) subgroups ( Figure 2 ). Significance was tested by Wilcoxon signed-rank tests. All vaccinated and COVID-19 convalescent subjects had significantly higher IgG-(p ≤ 0.0001) and IgA-levels (p ≤ 0.001) compared to the NI group (p-value not depicted in the graph). Significance was tested by Mann-Whitney U tests. **** = p ≤ 0.0001. The functional neutralizing activity of vaccine-or COVID-19 induced antibodies was analysed by an ELISA-based surrogate neutralization assay measuring the ability of serum to inhibit the binding of the ACE2 receptor to the SARS-CoV-2 spike receptor binding domain. This assay has been shown to have an equally high accuracy of determining antibody neutralization capacity compared to conventional neutralization assays using Figure S1a ). Among COVID-19 convalescent subjects, a significant correlation between the serum IgG and serum IgA antibody levels was observed in the HIV-1-infected as well as the HIV-1-uninfected subgroup (HIV: r 2 = 0.496, p < 0.0001; HU: r 2 = 0.304, p = 0.022, Supplementary Figure S2a ). The functional neutralizing activity of vaccine-or COVID-19 induced antibodies was analysed by an ELISA-based surrogate neutralization assay measuring the ability of serum to inhibit the binding of the ACE2 receptor to the SARS-CoV-2 spike receptor binding domain. This assay has been shown to have an equally high accuracy of determining antibody neutralization capacity compared to conventional neutralization assays using SARS-CoV-2 or pseudotyped vesicular stomatitis virus expressing SARS-CoV-2 spike [22, 23] . The BNT162b2 mRNA vaccine induced significantly higher neutralizing activity at a 1:5 serum dilution, both in HIV-1-infected and HIV-1-uninfected vaccinees, than the respective COVID-19 convalescent groups (Figure 3a , Supplementary Table S3) . Table S4 ). The significantly lower neutralizing activity of the HIV-1-infected patients at the 1:101 dilution compared to the HIV-1-uninfected subjects was also confirmed (p = 0.036, Table 6 ). Among the BNT162b2 mRNA vaccinated subjects, there was no significant difference in the serum neutralizing activity between HIV-1-infected subjects and HIV-1-uninfected controls at a 1:5 serum dilution, with levels close to 100% suggesting saturated experimental conditions. Further titration of sera from three donors with high or low neutralizing activity revealed that a 1:101 sample dilution might better reveal differences between samples with high neutralizing activity (Figure 3b ). At a 1:101 dilution, the serum neutralizing activity of the HIV-1-infected vaccinees was significantly lower compared to the HIV-1-uninfected vaccinated controls (p = 0.031, Figure 3c , Supplementary Table S3) . We observed a negative correlation between the neutralization capacity at both dilutions and the time after the second BNT162b2 mRNA vaccination in the subgroup of HIV-1-infected (1:5 r 2 = −0.153, p = 0.005; 1:101 r 2 = −0.138, p = 0.0078; Supplementary Figure S1h ) as well as the HIV-1-uninfected subjects (1:5 r 2 = −0.354, p < 0.0001; 1:101 r 2 = −0.341, p < 0.0001). Furthermore, the serum neutralizing activity at a 1:101 dilution showed a significant but weak negative correlation to the prime-boost interval in the HIV-1-uninfected subjects only (r 2 = −0.201, p < 0.0004, Supplementary Figure S1l ). Therefore, we performed multivariate analysis adjusting for age, gender, prime-boost interval, and time after second vaccination. This analysis confirmed the significant difference in neutralizing activity between the BNT162b2 mRNA vaccinated and the COVID-19 convalescent subjects (Supplementary Table S4 ). The significantly lower neutralizing activity of the HIV-1-infected patients at the 1:101 dilution compared to the HIV-1-uninfected subjects was also confirmed (p = 0.036, Table 6 ). Thus, the spike-specific IgA and IgG antibodies were measurable in the BNT162b2 mRNA vaccinated and the COVID-19 convalescent HIV-1-infected patients, but both the serum IgA levels and the neutralizing capacity at a 1:101 dilution were significantly lower compared to the HIV-1-uninfected subjects in a multivariate linear regression analysis. Given that the mucous membranes of the nasal and oral cavity are the main entry points of SARS-CoV-2, salivary antibodies could be important contributors to immunity against SARS-CoV-2 infection. We therefore measured spike-specific IgG, spike-specific IgA, and neutralizing antibodies in the saliva of 61 of 159 participants from whom saliva was available. Initial titration experiments with saliva samples of the BNT162b2 mRNA vaccinated, the COVID-19 convalescent and the SARS-CoV-2 non-immune subjects, allowed determination of a 1:10 dilution as the optimal dilution resulting in detectable spike-specific antibody levels with minimal background (Figure 4a ). At 1:10 saliva dilution, 5/15 (33%) vaccinated HIV-1-uninfected subjects each had detectable anti-spike IgA and IgG levels in saliva (Table 7 ). In HIV-1-infected vaccinees, anti-spike IgA was detected in 5/19 (26%) subjects and anti-spike IgG in 2/19 (11%) subjects (Table 7) . Among COVID-19 convalescent subjects, 5/8 (63%) HIV-1-uninfected and 9/13 (69%) HIV-1-infected subjects had detectable anti-spike IgA in saliva, whereas 0/8 (0%) HIV-1uninfected and 1/13 (8%) HIV-1-infected subjects had detectable anti-spike IgG in saliva. Saliva anti-spike IgA prevalence was higher among COVID-19 convalescent subjects compared to BNT162b2 mRNA vaccinated subjects, but this difference was insignificant (p = 0.068). In COVID-19 convalescent subjects, anti-spike IgG prevalence in saliva was lower compared to anti-spike IgA (p = 0.031). While these data may reflect differences in mucosal antibody responses between BNT162b2 mRNA vaccinated and COVID-19 convalescent groups, there was no significant difference in the prevalence of anti-spike IgA or IgG antibodies in saliva between the HIV-1-infected and the HIV-1-uninfected subjects. Regarding antibody levels, saliva spike-specific IgG levels were significantly higher in the BNT162b2 mRNA vaccinated groups and in the HIV-1-uninfected COVID-19 convalescents compared to the SARS-CoV-2 non-immune control group, but only 8 of 55 vaccinated or convalescent subjects had levels above the positive threshold of 1.1 (Figure 4b , Table 7, Supplementary Table S5 ). Although more subjects had detectable levels of anti-spike IgA in saliva (24 of 55 vaccinated or convalescent subjects), there was only a significant difference in frequencies of IgA in saliva between the HIV-1-infected BNT162b2 mRNA vaccinated and the HIV-1-infected COVID-19 convalescent groups. No significant difference was found between the HIV-1-infected and the HIV-1-uninfected subjects within each group (Figure 4b, Supplementary Table S5 ). To compare saliva antibody levels among persons with detectable levels, data were normalized to saliva total protein content for each subject. Vaccinated HIV-1-uninfected persons showed the highest levels of anti-spike IgG antibodies in saliva (median 1.3) but rare IgG seroprevalence in other groups did not allow statistical comparison of anti-spike IgG levels (Table 8 ). For IgA, the HIV-1-uninfected persons showed higher median levels within the vaccinated or COVID-19 convalescent subgroups, but these differences did not reach statistical significance (Table 8 ). Measurement of neutralizing antibodies by the ELISA-based surrogate neutralization assay required a 1:5 dilution of saliva samples. We were able to detect saliva neutralizing antibodies only in one vaccinated subject, but in none of the COVID-19 convalescent patients. Additionally, 4/21 subjects of the COVID-19 group as well as 5/34 vaccinated donors displayed borderline neutralizing capacities of 20-35% in saliva. However, these levels of neutralizing activity did not significantly differ from those of the SARS-CoV-2 non-immune control group, irrespective of HIV status (Figure 4c) . Overall, the anti-spike IgA and IgG antibodies were distinctly less prevalent in saliva compared to serum of the COVID-19 convalescent and the BNT162b2 mRNA vaccinated groups. Despite detectable saliva anti-spike antibodies among the HIV-1-infected and the HIV-1-uninfected subjects, almost no saliva neutralizing capacity was observed in our cohort. In this study, we investigated the humoral SARS-CoV-2-specific immune response in HIV-1-infected subjects on antiretroviral therapy with a controlled HIV-1 viremia of ≤60 copies/mL. All HIV-1-infected subjects in this study were able to mount SARS-CoV-2specific IgG antibody responses after a two-dose BNT162b2 mRNA vaccination. Notably, we observed lower serum anti-spike IgA and neutralizing antibody levels in HIV-1-infected subjects after adjustment for age, gender, prime-boost interval, and time after second vaccine dose, denoting a negative effect of the HIV infection on BNT162b2 mRNA-induced humoral responses. Our study is in line with several recent reports on HIV-1-infected individuals mounting robust spike-specific IgG antibody responses to vaccination with BNT162b2 mRNA, Moderna mRNA-1273 vaccine and ChAdOx1 nCoV-19 vaccines [5, [24] [25] [26] [27] [28] [29] [30] comparable to healthy control groups in the majority of studies. Apart from spike-specific IgG, we were also able to detect spike-specific IgA in the serum of all vaccinated study subjects, demonstrating that the intramuscular application of the BNT162b2 mRNA vaccine can induce both IgA and IgG antibodies in HIV-1-infected subjects and in HIV-1-uninfected controls although at lower levels than IgG. This is in line with reports of other groups describing the induction of spike-specific IgG and IgA antibodies by mRNA vaccines in HIV-1-uninfected subjects, with anti-spike antibody levels being consistently higher in vaccinated persons compared to COVID-19 convalescent and serum IgG levels being higher than IgA levels [31] [32] [33] [34] [35] . Here, the neutralizing activity correlated significantly with the spike-specific IgG and IgA titers in the serum of HIV-1-infected and -uninfected donors. Studies from other groups showed that both spike-specific IgG and IgA antibodies exhibit SARS-CoV-2 neutralizing activity [36] but the relative importance of neutralizing IgA antibodies compared to the IgG antibodies for serum neutralization and outcome of SARS-CoV-2 infection is still unclear. Thus, the relative contribution of serum IgA to SARS-CoV-2 immunity remains to be clarified in future studies and may be influenced by its relatively lower half-life compared to IgG [32] . In our study, the assessment of the functional activity of the spike-specific antibodies by a surrogate neutralization assay showed that the vaccine was able to generate potent neutralizing activity in serum of both HIV-1-uninfected and HIV-1-infected subjects. However, the significantly lower neutralizing activity at a 20-fold higher serum dilution in the HIV-1-infected subjects than in the HIV-1-uninfected controls indicates a moderate impairment of the humoral immune response in cART-treated HIV-1 infection as seen with other vaccines [8] [9] [10] [11] . This is unlikely to be explained by depletion of CD4 + T-cells in the blood, as all patients in our study showed normal or only moderately decreased CD4 + T-cells with a median CD4 + T-cells count of 634/µL (range 234-1548) and the CD4 + T-cells counts did not correlate to the spike-specific IgG-levels and neutralizing activity in the HIV-1-infected vaccinees. A lack of correlation of spike-antibody titers to CD4 counts in cART treated HIV-1-infected patients was also reported in the study of Frater et al. [29] who investigated the spike-specific antibody titers after vaccination with ChAdOx1 in a similar patient group. Nonetheless, incomplete immune reconstitution is commonly reported in cART-treated HIV-1-infection. Incomplete recovery of the repertoire of CD4 + T-cells despite normalization of numbers in the peripheral blood, alterations in the differentiation of CD4 + T-cell subsets [37] and ongoing immune activation interfering with an efficient immune reconstitution [38] could all play a role in reduced vaccine efficacy. The duration of cART did not correlate to spike-specific IgG, spike-specific IgA and neutralizing antibody titers in a multivariate analysis including the years on antiretroviral therapy. Moreover, the prevalence of co-morbidities commonly seen in HIV-1 infection such as diabetes, hepatitis B infection could also influence vaccine efficacy. In our study, a limited number of participants (30 out of 82 HIV-1-infected) had any co-morbidities, and our analysis did not show association with antibody responses. Longitudinal studies are needed to clarify whether lower titers of neutralizing spike-specific antibodies observed in our study will be associated with a more rapid decline of humoral immunity and an increased susceptibility to SARS-CoV-2 infection. A confounding factor in our study was age, as the spike-specific IgG levels showed a weak negative correlation to age and the HIV-1-infected patients were older than the control subjects. It is known that immune responses generally decrease with older age, and this could lead to lower spike-specific IgG titers. In contrast to spike-specific IgG, we did not observe a correlation of spike-specific IgA and neutralizing antibodies to age. A recent study [39] reported strong negative correlation between age and both SARS-CoV-2-specific IgG and neutralizing antibody levels after mRNA vaccination, but the median age in that study was much higher in the older adult group (79 years) compared to the group of HIV-1-infected subjects in our study (55 years). Furthermore, our multivariate linear regression analysis adjusting for age as well as gender, prime-boost interval, and time after second vaccine dose reveals an effect of HIV-1 infection on serum anti-spike IgA and neutralizing antibody levels but not on anti-spike IgG levels. Our findings are different from other studies reporting similar BNT162b2 mRNA-induced serum anti-spike neutralizing antibody levels between HIV-1-infected persons and healthy controls [5, 7, 40, 41] . Differences in sampling time could account for divergence in findings, with our sampling time up to 7.5 weeks in HIV-1-infected and 9.5 weeks in HIV-1-uninfected as opposed to 1-4 weeks. Of note, recent studies on inactivated SARS-CoV-2 vaccines reported similar SARS-CoV-2-specific neutralizing antibody responses between HIV-infected persons and healthy controls up to 4 weeks after vaccination [42] contrasting with lower SARS-CoV-2-specific neutralizing antibody responses in HIV-infected persons 40 days [43] or up 84 days [44] after vaccination. Thus, a faster decay of antibody responses may account for our observation of lower antibody responses after BNT162b2 mRNA vaccination in HIV-1 infection. Differences in sampling time between groups in our study warrant caution with respect to estimating the precise impact of HIV-1 infection on antibody levels after BNT162b2 mRNA vaccination. To assess the potency of the BNT162b2 mRNA vaccine we compared the humoral immune response of the vaccinees with that of subjects who had recovered from SARS-CoV-2 infection. Indeed, the BNT162b2 mRNA vaccine induced significantly higher spike specific IgG levels compared to SARS-CoV-2 infection. Importantly, vaccination with the BNT162b2 mRNA also induced significantly more spike-specific neutralizing antibodies in the serum compared to the COVID-19 convalescent individuals. The strong differences in the spike-specific IgG levels and the neutralization activity between the vaccinated subjects and the convalescent subjects was influenced by a shorter observation time after the second BNT162b2 mRNA vaccination compared to the observation time after the recovery from active SARS-CoV-2 infection as SARS-CoV-2 antibodies display a two-phase decay after infection [14, 23] . However, even after adjustment for time after the second vaccination or infection, the spike-specific IgG levels were significantly higher in vaccinated subjects than the COVID-19 convalescent subjects. This is also in accordance with other studies reporting higher antibody titers after vaccination than after natural infection in non-hospitalized COVID-19 patients [6, 14, 34, [45] [46] [47] [48] . In the convalescent subjects, no difference was found between the HIV-1-infected and the uninfected individuals regarding spike-specific IgG and IgA levels and with the neutralizing serum activity at a 1:5 dilution. This finding is in accordance with the report by Alrubayyi et al. [49] who described similar spike-specific IgG levels and neutralizing antibody titers in the HIV-1-infected patients on ART in comparison to the uninfected controls. In contrast, lower spike-specific IgG titers and pseudovirus neutralizing antibody titers were reported on a cohort of HIV-1-infected subjects from San Francisco [50] . This difference could be explained by lower CD4 counts in that cohort (median CD4 452/µL versus CD4 of 551/µL in this study and CD4 of 571/µL in Alrubayyi et al. [49] ) as the authors described significantly lower spike antibody titers in patients with CD4 < 200/µL versus CD4 > 200/µL [50] . Apart from serum, we could also detect spike-specific antibodies in saliva, albeit at lower frequencies and titers than in the serum. Akin to the study of Becker et al. [31] , vaccinated subjects displayed spike-specific IgG-responses similar to IgA-responses in saliva, whereas in saliva of convalescent subjects, spike-specific IgA antibodies were more frequently observed than spike-specific IgG antibodies. This may suggest that the location of the priming of the immune response influences the differentiation of B-cells with induction of a stronger spike-specific IgA response by infection via the mucosal route in contrast to the intramuscular application of the vaccine. Other groups recently reported mucosal antibodies both after SARS-CoV-2 infection and vaccination. In most of those studies, spike-specific saliva antibodies could be detected at higher frequencies than in our study [31, 35, 40, [51] [52] [53] . This difference could be influenced by the method of saliva sample collection. In our study, saliva was sampled by spitting into a collection tube, while other studies utilized oral swabs or mouthwash samples [52] . In some reports, the saliva samples were concentrated after a centrifugation step [52, 53] , treated with additives [35] or heat-inactivated [40] . Furthermore, different serological assays were used for the measurement of antibodies. These differences most likely lead to different sensitivities regarding the detection of saliva antibodies. In line with our study, Azzi et al. showed that the saliva antibody levels are substantially lower than the serum IgG and IgA levels [54] . In this study, neutralizing activity in saliva was only detected at low frequencies. In summary, our study clearly demonstrates that the BNT162b2 mRNA vaccine induces a robust SARS-CoV2 spike specific humoral immune response both in HIV-1uninfected subjects and in HIV-1-infected patients on antiretroviral therapy, exceeding the antibody response observed in SARS-CoV-2 infected subjects. Nevertheless, vaccine induced serum neutralization activity and SARS-CoV-2-specific IgA levels were significantly lower in HIV-1-infected patients than in HIV-1-uninfected subjects, indicating a moderately lower functionality of the humoral vaccine response. Longitudinal studies are necessary to investigate whether this moderately lower antibody response in HIV-1-infected subjects will lead to a lower vaccine efficacy over time. Low titers of spike antibodies and low neutralizing activity in saliva in comparison to strong antibody titers and neutralization activity serum could explain the risk of infection of both vaccinated and convalescent subjects despite good protection from symptomatic disease. Safety and Efficacy of the BNT162b2 mRNA COVID-19 Vaccine Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: An interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK Safety and Efficacy of Single-Dose Ad26.COV2.S Vaccine against COVID-19 Efficacy of the mRNA-1273 SARS-CoV-2 Vaccine at Completion of Blinded Phase The BNT162b2 mRNA Vaccine Elicits Robust Humoral and Cellular Immune Responses in People Living with Brief Report: Humoral and cellular immune responses to SARS-CoV-2 infection and vaccination in B cell depleted autoimmune patients BNT162b2 mRNA COVID-19 vaccination in immunocompromised patients: A prospective cohort study Immune reconstitution and vaccination outcome in HIV-1 infected children: Present knowledge and future directions Humoral and Cellular Response to Influenza Vaccine in HIV-Infected Children With Full Viroimmunologic Response to Antiretroviral Therapy Herpes Zoster and Herpes Zoster Vaccine Rates Among Adults Living With and Without HIV in the Veterans Aging Cohort Study Hepatitis B vaccine responses in a large U.S. military cohort of HIV-infected individuals: Another benefit of HAART in those with preserved CD4 count Prospects for durable immune control of SARS-CoV-2 and prevention of reinfection Antibody titers and protection against a SARS-CoV-2 infection Neutralizing antibody levels are highly predictive of immune protection from symptomatic SARS-CoV-2 infection Immune correlates of protection by mRNA-1273 vaccine against SARS-CoV-2 in nonhuman primates HIV infection and the gastrointestinal immune system Impact of cytokine inhibitor therapy on the prevalence, seroconversion rate and longevity of the humoral immune response against SARS-CoV-2 in an unvaccinated cohort Patients with immune-mediated inflammatory diseases receiving cytokine inhibitors have low prevalence of SARS-CoV-2 seroconversion Evaluation of the EUROIMMUN Anti-SARS-CoV-2 ELISA Assay for detection of IgA and IgG antibodies SARS Coronavirus-2 Microneutralisation and Commercial Serological Assays Correlated Closely for Some but Not All Enzyme Immunoassays Systemic and mucosal antibody responses specific to SARS-CoV-2 during mild versus severe COVID-19 A SARS-CoV-2 surrogate virus neutralization test based on antibody-mediated blockage of ACE2-spike protein-protein interaction Evolution of immune responses to SARS-CoV-2 in mild-moderate COVID-19 Humoral immune responses to COVID-19 vaccination in people living with HIV receiving suppressive antiretroviral therapy Immunogenicity and safety of the BNT162b2 COVID-19 mRNA vaccine in PLWH: A monocentric study in Bari, Italy Jonsson-Oldenbuettel, C. Humoral response to SARS-CoV-2 vaccines in people living with HIV Safety and antibody response to two-dose SARS-CoV-2 messenger RNA vaccination in persons with HIV Safety and immunogenicity of the ChAdOx1 nCoV-19 (AZD1222) vaccine against SARS-CoV-2 in people living with and without HIV in South Africa: An interim analysis of a randomised, double-blind Safety and immunogenicity of the ChAdOx1 nCoV-19 (AZD1222) vaccine against SARS-CoV-2 in HIV infection: A single-arm substudy of a phase 2/3 clinical trial Immunogenicity and safety of the BNT162b2 mRNA COVID-19 vaccine in people living with HIV-1 Immune response to SARS-CoV-2 variants of concern in vaccinated individuals Human IgG and IgA responses to COVID-19 mRNA vaccines A mucosal antibody response is induced by intra-muscular SARS-CoV-2 mRNA vaccination COVID-19 mRNA vaccine induced antibody responses against three SARS-CoV-2 variants Antibody Responses to SARS-CoV-2 mRNA Vaccines Are Detectable in Saliva Enhanced SARS-CoV-2 neutralization by dimeric IgA Altered differentiation is central to HIV-specific CD4(+) T cell dysfunction in progressive disease T cell activation is associated with lower CD4+ T cell gains in human immunodeficiency virus-infected patients with sustained viral suppression during antiretroviral therapy Reduced magnitude and durability of humoral immune responses to COVID-19 mRNA vaccines among older adults Salivary IgG to SARS-CoV-2 indicates seroconversion and correlates to serum neutralization in mRNA-vaccinated immunocompromised individuals Anti-spike antibodies and neutralising antibody activity in people living with HIV vaccinated with COVID-19 mRNA-1273 vaccine: A prospective single-centre cohort study Immunogenicity of an inactivated SARS-CoV-2 vaccine in people living with HIV-1: A non-randomized cohort study Inactivated SARS-CoV-2 vaccines elicit immunogenicity and T-cell responses in people living with HIV Comparing Immune Responses to Inactivated Vaccines against SARS-CoV-2 between People Living with HIV and HIV-Negative Individuals: A Cross-Sectional Study in China Initial observations on age, gender, BMI and hypertension in antibody responses to SARS-CoV-2 BNT162b2 vaccine Immunogenicity of BNT162b2, BBIBP-CorV and Gam-COVID-Vac vaccines and immunity after natural SARS-CoV-2 infection-A comparative study from Novi Sad, Serbia Large-scale study of antibody titer decay following BNT162b2 mRNA vaccine or SARS-CoV-2 infection COVID-19 vaccine BNT162b1 elicits human antibody and TH1 T cell responses Characterization of humoral and SARS-CoV-2 specific T cell responses in people living with HIV SARS-CoV-2 seroprevalence, and IgG concentration and pseudovirus neutralising antibody titres after infection, compared by HIV status: A matched casecontrol observational study Assessment of salivary antibody response to BNT162b2 mRNA COVID-19 vaccination ELISA detection of SARS-CoV-2 antibodies in saliva Developing an Optical Interferometric Detection Method based biosensor for detecting specific SARS-CoV-2 immunoglobulins in Serum and Saliva, and their corresponding ELISA correlation Mucosal immune response in BNT162b2 COVID-19 vaccine recipients We thank all patients and volunteers for participating in this study. The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, or in the decision to publish the results.