key: cord-0701566-u2n2tf31 authors: Shin, Wonseok; Lee, Cherl-Joon; Lee, Yong-Moon; Choi, Young-Bong; Mun, Seyoung; Han, Kyudong title: Rapid identification of SARS-CoV-2 in the point-of-care using digital PCR-based Dr. PCR™ Di20K COVID-19 Detection Kit without viral RNA extraction date: 2022-03-30 journal: Genes Genomics DOI: 10.1007/s13258-022-01242-z sha: 5e72f8f6b30a4497d61fbd6c7990dd1542ff27d1 doc_id: 701566 cord_uid: u2n2tf31 BACKGROUND: Since COVID-19 was declared the pandemic by the WHO, it has continued to spread. There is a need for rapid, efficient, and accurate diagnostic kits and techniques to control its spread. OBJECTIVE: The diagnostic capability of the qRT-PCR-based Real-Q 2019-nCoV Detection Kit and dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit was compared and evaluated. METHODS: Diagnostic tests for COVID-19 were performed using two different COVID-19 kits and 301 individual specimens with confirmed COVID-19 positive/negative at the government-accredited medical institution. Assessment of diagnostic capability was measured through diagnostic sensitivity, specificity, Cohen’s Kappa coefficient, and dilutional linearity tests. RESULTS: The COVID-19 diagnostic test results using two kits and 301 individual specimens perfectly matched the pre-diagnosis results of the medical institution. In addition, the measurement results of diagnostic sensitivity and specificity were “1”, indicating high diagnostic capability. Cohen’s Kappa coefficient value is “1”, which means that the diagnosis concordance between the two kits is “Almost Perfect”. As a result of dilutional linearity tests to evaluate their detection capability, both kits were measured with very high detection reliability. CONCLUSION: Here, we propose that the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit has the advantages of the dPCR method reported in the previous study and is suitable for point-of-care testing (POCT) by overcoming the limitations of space, test time, cross-over contamination, and biosafety due to omitting RNA extraction process. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13258-022-01242-z. Currently, coronavirus disease of 2019 , which has continued to spread throughout the world, was officially declared a "pandemic" in March 2020 by the World Health Organization (WHO) (Balkhair 2020; Lone and Ahmad 2020; Mo et al. 2021) . The causative virus of COVID-19 is Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), a new type of coronavirus. This virus belongs to the subgenus Sarbecovirus of the genus Betacoronavirus and has been reported to cause fatal respiratory disease in humans (Utku et al. 2020; Wang et al. 2020) . The main route of transmission COVID-19 is from an infected person to uninfected people through respiratory aerosols and droplets conveying the SARS-CoV-2 (Harrison et al. 2020; Lotfi et al. 2020; Syal 2021) . To date, vaccines against SARS-CoV-2 have been developed by various global pharmaceutical companies such as Pfizer Inc., AstraZeneca PLC, Moderna Inc., and Janssen Inc. to prevent the spread of COVID-19 (Kaur and Gupta 2020) . Nevertheless, new SARS-CoV-2 mutations (Alpha, Beta, Gamma, Delta, Omicron, etc.) with 1.5-2 times higher infectivity have appeared, and the disease continues to spread due to the absence of an effective therapeutic agent (Khan et al. 2022 ). In addition, poor diagnosis and asymptomatic transmission have accelerated the rapid spread of COVID-19. Therefore, it is crucial to control the further spread of COVID-19 through prompt and accurate diagnosis in SARS-CoV-2 infected patients along with the development of therapeutic agents and vaccines. Globally, quantitative Real-time reverse transcription polymerase chain reaction (qRT-PCR), Digital PCR (dPCR), Whole-genome sequencing, Nanopore target sequencing (NTS), Antibody detection, Antigen detection, and CRISPR-Cas system-based method (e.g., SHERLOCK) are being applied as detection methods for SARS-CoV-2 (Eftekhari et al. 2021; Giri et al. 2021; Liu et al. 2020 ). Among various detection methods, the qRT-PCR is a method based on viral RNA amplification (Falzone et al. 2021) . It detects using primers and probes sets composed of specific viral sequences of SARS-CoV-2 such as E gene, RdRp gene, and N gene. Most antibody detection methods determine whether the virus is detected by measuring the levels of IgM and IgG in the immune system. Typically, lateral flow type assays (LFA) and enzyme-linked immunosorbent type assays (ELISA) are mainly used (Mahmoudinobar et al. 2021 ). However, antibody detection methods can lead to falsepositive results due to cross-reactivity in which an antibody binds to an antigen with high molecular similarity other than the target antigen (Liu and Rusling 2021) . A person infected with SARS-CoV-2 usually develops antibodies after about 14 days (Cevik et al. 2020; Wolfel et al. 2020) . According to the results of a recent study, it has been reported that IgG and IgM can be detected 5 days after infection (Loeffelholz and Tang 2020) . Thus, antibody detection methods have a disadvantage that can lead to false-negative results if sufficient antibodies for diagnosing COVID-19 are not formed (Chang et al. 2020) . Antigen detection methods are intuitive and straightforward diagnostic methods for COVID-19 (Yuce et al. 2021) . Like antibody detection methods, these methods can be performed by LFA or ELISA. However, these methods have low sensitivity compared to nucleic acid testing and do not satisfy the clinical sensitivity criteria (96%) of the Ministry of Food and Drug Safety of the Republic of Korea (MFDS) guideline (Department 2020). In particular, the qRT-PCR method based on viral RNA amplification is considered a gold standard because it has almost 100% specificity and high accuracy (> 97%), unlike other molecular tests that do not have perfect diagnostic specificity (Garg et al. 2021; Teymouri et al. 2021) . Although most laboratories diagnose COVID-19 with the qRT-PCR method, there are some weaknesses. It is still difficult to accurately diagnose low viral load in the early stages of SARS-CoV-2 infection (Gupta et al. 2021) . In general, this method requires the RNA extraction step and thus has several problems such as cross-contamination, additional experiment cost, and time (Ref 24, 25) . In addition, the cost of the qRT-PCR equipment is relatively high, and diagnostic space is limited due to its size. Nowadays, the dPCR method, which complements the relative disadvantages of the qRT-PCR method, is drawing attention in COVID-19 diagnostics. In a previous study, LOAA dPCR equipment (Optolane, Seongnam, Republic of Korea) with dPCR-based Dr. PCR 20 K COVID-19 Detection Kit (Cat no. DCM402-X, Optolane, Seongnam, Republic of Korea) system has been reported that it is less affected by PCR inhibitors than the typical qRT-PCR assay and can be detected even at low viral loads (Lee et al. 2021a; Sidstedt et al. 2020 ). In addition, this system has high diagnostic sensitivity and specificity. However, this system requires the RNA extraction step and various resources such as consumables costs and experimental time, as well as carry-over contamination and biosafety risks when handling clinical samples (Wee et al. 2020) . Approved by MFDS in March 2021, Dr. PCR™ Di20K COVID-19 Detection Kit (Optolane, Seongnam, Republic of Korea) was newly released. It can be applied to the LOAA dPCR system. This system is designed to overcome the weak points of the existing qRT-PCR and dPCR methods. In addition, since it is possible to diagnose COVID-19 without a viral RNA extraction step, rapid test results and efficient point-of-care testing (POCT) can be predicted. Through this system, it is expected to quickly and accurately screen patients suspected of having COVID-19 to inhibit the spread of the virus. Here, we measured the diagnostic capability of the LOAA dPCR assay with dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit. In this study, the Real-Q 2019-nCoV Detection Kit (Biosewoom, Seoul, Republic of Korea) , one of the qRT-PCR-based method kits considered as the gold standard in diagnosing of COVID-19, was selected as a comparison kit for the assessment of COVID-19 diagnostic capability. This kit was reported to have high sensitivity (98.2%) and specificity (100%) in previous studies (Chung et al. 2021) . We compared and analyzed the diagnostic capability between the two kits using residual samples from the upper respiratory of 101 positive and 200 negative samples tested with COVID-19 diagnosis a government-certified medical institution. The government of the Republic of Korea has selected medical institutions with excellent clinical evaluation capabilities and supported these institutions to sufficiently secure various COVID-19 specimens such as blood and respiratory-derived samples. In this study, a total of 301 upper respiratory samples were collected from nasopharyngeal swab (NPS) and oropharyngeal swab (OPS) in Samkwang Medical Laboratories (SML, Seoul, Republic of Korea) among these institutions. The collected samples are 101 positive and 200 negative specimens tested with COVID-19 diagnosis at the SML institution, which are residual samples extracted from adult males and females over twenty. All swabs were each stored in 3 mL of viral transport media (VTM, Cat. No UTNFS-3B-1, Noble Biosciences, Inc., Hwaseong, Republic of Korea). This study was conducted considering the Declaration of Helsinki and the International Conference on Harmonization Good Clinical Practice guidelines and approved through SML Institutional Review Board (S-IRB-2020-032-10-22). Donors for this study submitted written consent prior to participation. Viral RNAs were extracted from 301 upper respiratory samples using each 250 μL of the VTM with the MagNa pure 96 system (Roche, Basel, Switzerland), an automated nucleic acid extractor, following the manufacturer's instructions (Edelmann et al. 2013; Hindiyeh et al. 2019) . The extracted viral RNAs were each dissolved in 50 μL of RNase-free water. The eluted RNA samples were stored at − 80 °C in a deep freezer. To evaluate the COVID-19 detection capability of the Real-Q 2019-nCOV Detection Kit (BioSewoom, Seoul, Republic of Korea), the qRT-PCR assay was performed using the stored RNA samples from the 301 specimens. It was carried out following the protocol of the manufacturer. The Real-Q 2019-nCOV Detection Kit includes primer sets and probes targeting the E and RdRp genes of SARS-CoV-2 (Fig. 1) . The qRT-PCR was performed by the following process: cDNA synthesis of 30 min at 50 °C, pre-denaturation of 15 min at 95 °C, followed by 40 cycles of denaturation 15 s at 95 °C, 45 s at 62 °C for annealing and extension. CFX96™ Real-Time PCR Detection System (Bio-Rad, Hercules, CA, USA) was applied to qRT-PCR assay ( Fig. 2 ) (Cho et al. 2020 ). The LOAA dPCR System (Optolane, Seongnam, Republic of Korea) is a compact separation type dPCR instrument released in 2020 (Lee et al. 2021b) . This system was applied to the dPCR assay. To evaluate the SARS-CoV-2 detection capability of Dr. PCR™ Di20K COVID-19 Detection Kit (Cat no. COM401-Z, Optolane, Seongnam, Republic of Korea), we carried out LOAA dPCR assay using the 301 VTMs. This assay with Dr. PCR™ Di20K COVID-19 Detection Kit was conducted according to the user guideline of the manufacturer (Fig. 3 ). Since the experimental procedure of this kit omits the viral RNA extraction step, VTMs were directly used for dPCR assay. Dr. PCR™ Di20K COVID-19 Detection Kit contains the sets of primers and probes that target the E and RdRp genes of SARS-CoV-2. The dPCR was performed by the following process: cDNA synthesis of 10 min at 50 °C, pre-denaturation of 30 min at 95 °C, followed by 40 cycles of denaturation 5 s at 95 °C, 10 s at 57 °C for annealing and extension. The To compare the SARS-CoV-2 detection capabilities of each kit following the dilution factor (10 -1 to 10 -7 ), we carried out a dilution linearity analysis by the spike-in high concentration of SARS-CoV-2 positive sample (almost Ct value > 20) to the negative sample. The Real-Q 2019-nCoV Detection Kit with high clinical specificity and sensitivity is commonly used for COVID-19 diagnosis in South Korea. To evaluate the diagnostic capability of the qRT-PCR-based Real-Q 2019-nCoV Detection Kit, we carried out a qRT-PCR assay with 301 residual samples derived upper respiratory tested for COVID-19 at the Samkwang Medical Laboratories (SML, Seoul, Republic of Korea. The SARS-CoV-2 detection results of the qRT-PCR-based Real-Q 2019-nCoV Detection Kit were measured as Ct values. The PCR amplification targets were the E gene, RdRp gene of SARS-CoV-2, and internal control (IC, Human RNase P gene). As shown in Table 1 , the classification of results using this assay is reported as a total of five CASE types (CASE 1 to 5). When the Ct values of each E gene (HEX/VIC dye) ≤ 38, RdRp gene (FAM dye) ≤ 38, and IC (Cy5 dye) ≤ 35, it is described as "Detection" (+), and exceeding each cut-off is indicated as "Not detection" (-). According to the (+) or (-) result of each gene, CASE 1 and 2 are determined as "2019-nCoV positive". In the case of CASE 3, IC is ( ±), E gene is (+), and RdRp gene is (-), which is determined as "Presumptive positive for 2019-nCoV" and retesting is recommended (BioSewoom 2020). If the IC is (+) and the E and RdRp genes are (-) in the sample, it is classified as CASE 4 and finally determined as "Negative" for COVID-19. A sample with results obtained as (-) for all target genes is "invalid" and corresponds to CASE 5. As a result of carrying out a COVID-19 diagnosis using the qRT-PCR-based Real-Q 2019-nCoV Detection Kit with a total of 301 individual samples, 101 specimens tested positive for COVID-19, and 200 specimens determined negative for COVID-19 (Supplementary Table S1 ). The positive samples were OP001 to OP020, OP061 to OP080, OP121 to OP140, OP181 to OP200, OP241 to OP261, all of which were individual samples of patients diagnosed with COVID-19 at the medical institution. In addition, the negative samples were OP021 to OP060, OP081 to OP120, OP141 to OP180, OP201 to OP240, OP262 to OP301, and were all individual samples derived from normal individuals in which SARS-CoV-2 was not detected at the same medical Although the sample size was relatively small, it was measured with very high diagnostic sensitivity (100%) and specificity (100%) ( Supplementary Table S2 ). Thus, we confirmed that the qRT-PCR-based Real-Q 2019-nCoV Detection Kit has high diagnostic accuracy in the COVID-19 diagnosis. To evaluate the diagnostic accuracy of the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit, a COVID-19 diagnostic test was performed with the same 301 individual samples evaluated above. The results of the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit were (2) Specificity(%) = Ture negative True negative + False positive analyzed based on positive wells. This dPCR assay amplifies the E gene, RdRP gene of SARS-CoV-2, and PCR Control (PCRC) to determine the diagnosis of COVID-19. The dPCR assay results are valid when the number of positive wells is 10,000 or more. In addition, positive control material is RdRp (FAM dye) ≥ 2, E gene (FAM dye) ≥ 2, PCRC (Cy5 dye) ≥ 10, and NTC is RdRp (FAM dye) < 2, E gene (FAM dye) < 2, PCRC (Cy5 dye) ≥ 10, it is determined to be valid. The COVID-19 diagnostic test for individual samples is automatically determined as CASE 1-9 based on positive wells (Table 2) . A total of 301 identical individual samples evaluated through the above qRT-PCR assay was analyzed for COVID-19 diagnostic capability using the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit. As a result of the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit, 101 specimens were positive for COVID-19, and 200 specimens were negative. The 101 positive individual specimens were OP001 to OP020, OP061 to OP080, OP121 to OP140, OP181 to OP200, OP241 to OP261, all of which were extracted from patients diagnosed with COVID-19 at the medical institution. The 200 negative individual specimens were OP021 to OP060, OP081 to OP120, OP141 to OP180, OP201 to OP240, OP262 to OP301, all of which were tested negative for COVID-19 at the same medical institution. The results of the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit are 100% consistent with the results of the COVID-19 diagnostic test at the medical institution in all individual samples. Therefore, in the case of COVID-19 diagnostic evaluation using this kit, the false-positive and false-negative ratio values were confirmed as "0". In addition, to evaluate diagnostic accuracy, we calculated the diagnostic sensitivity and specificity of the Dr. PCR™ Di20K COVID-19 Detection Kit by comparing the results of the Retest is recommended a E gene (-) and/RdRP gene (+) result could be casued by (1) a specimen at concentrations near or below the limit of detection of the test, (2) a mutation in the E gene target region in the oligonucleotide binding sites, (3) other factors b E gene (+) and/RdRP gene (-) result could be caused by (1) a specimen at concentrations near or below the limit of detection of the test, (2) a mutation in the RdRP target region in the oligonucleotide binding sites, (3) dPCR assay with diagnostic results of the medical institutions in the individual specimens. Although the individual specimen size was relatively small, we confirmed that it was measured with very high diagnostic sensitivity (100%) and specificity (100%). As with the qRT-PCR assay, the sample size was relatively small. However, we confirmed that the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit has the same high diagnostic accuracy as the qRT-PCR assay used as a gold standard in diagnosing COVID-19 (Supplementary Table S3 ). This dPCR is expected to be easy to save experimental time and resources, which is important for the diagnosis of COVID-19 by omitting the RNA extraction step in the diagnostic test process. Through the COVID-19 diagnostic test of the qRT-PCRbased Real-Q 2019-nCoV Detection Kit and dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit, we confirmed that the diagnostic results using the two different kits were completely consistent. We calculated using Cohen's Kappa coefficient to measure the agreement and reliability between the two diagnostic results. The Kappa coefficient is a probability value, and the closer to 1, the higher the agreement between two different data (Czodrowski 2014) . When the COVID-19 diagnostic test results using the two kits were calculated by Cohen's Kappa coefficient, the value was "1" meaning "Almost Perfect". In order to evaluate the detection capability between the two different kits depending on the virus concentration, a high concentration of SARS-CoV-2 positive specimens (OP003, OP009, OP010, OP013, OP015, OP017, OP137, If the E gene is negative but the RdRP gene is positive, it is determined as "Undetermined", and if the same result is obtained after retesting, it is determined as positive c If the E gene is positive but the RdRP gene is negative, it is determined as "SARS-CoV" d If the 'Valid' condition is met in NTC, PC, or PCRC, use DEPC treated water to dilute 1/5 and then proceed with re-reaction e If the number of valid wells is less than 10,000, it is determined as invalid, and the cartridge is discarded and retested with a new cartridge OP190, OP253, OP260) was selected. The high concentration SARS-CoV-2 positive specimens were spike-in treated with the negative patient specimen, diluted, and then the dilutional linearity test was carried out based on C/uL. The correlation of the detection capabilities of two different kits was confirmed through the spike-in treatment of the negative patient specimen at the high concentration SARS-CoV-2 positive specimens. The dilutional linearity test was carried out after dilution of the treated individual specimen depending on the dilution factors from 10 −1 to 10 −7 (Table 3) . As shown in Table 4 , we confirmed that SARS-CoV-2 could be detected up to the dilution factor of 10 -5 in both results of the qRT-PCR-based Real-Q 2019-nCoV Detection Kit and the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit. Thus, this means that the dPCRbased Dr. PCR™ Di20K COVID-19 Detection Kit has the same detection capability as the qRT-PCR-based Real-Q 2019-nCoV Detection Kit approved by FDA-Emergency Use Authorization (EUA) and MFDS-EUA. In addition, the results of regression analysis measured depending on the dilution factors of 10 randomly selected individual specimens (OP003, OP009, OP010, OP013, OP015, OP017, OP137, OP190, OP253, OP260) were average R 2 = 0.99915 in the qRT-PCR assay with Real-Q 2019-nCoV Detection Kit and average R 2 = 0.98515 in the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit ( Fig. 4; Fig. S1 ; Fig. S2 ). This means that both kits have high detection reliability (Gougeon 2005) . In summary, dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit has the same high detection reliability as the qRT-PCR method. In addition, this kit has the advantages of the dPCR method as reported in the previous study, and at the same time, omits the RNA extraction step, suggesting that the SARS-CoV-2 can be detected relatively quickly. Correlation analysis of the two kits was performed using the detection level results of SARS-CoV-2 E and RdRp genes in the ten individual samples analyzed to the above dilutional linearity test. R 2 values were measured by performing regression analysis based on the Ct value in the qRT-PCR assay and the C/uL value in the dPCR assay. As a result of the measurement, the average R 2 = 0.9908 in the E gene and R 2 = 0.9947 in the RdRp gene ( Fig. 5; Fig. S3; Fig. S4 ). This means that there is a high correlation between the qRT-PCR assay with Real-Q 2019-nCoV Detection Kit and the dPCR assay with Dr. PCR™ Di20K COVID-19 Detection Kit for these two genes. As the COVID-19 pandemic continues worldwide, the need for a rapid and accurate detection method of SARS-CoV-2 continues to grow. Thus, we compared the diagnostic capability of the recently released dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit (approved by the Korea MFDS) without the viral RNA extraction step and the qRT-PCR-based Real-Q 2019-nCoV Detection Kit (approved by the US FDA EUA and the Korea MFDS EUA) commonly used in Korea. We obtained the 301 individual specimens with confirmed COVID-19 positive/negative from the government-accredited medical institution and performed the SARS-CoV-2 detection test using these two kits. The results of both kits confirmed that the COVID-19 diagnosis was perfectly matched, and the clinical sensitivity and specificity were 100%. In addition, the dilutional linearity test demonstrated that both of these kits were capable of detection at low viral loads (10 -5 ) with high confidence. However, the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit could cover the weaknesses of the qRT-PCR-based method. In addition, since this kit omits the RNA extraction step, the test time of approximately 1-2 h can be shortened, thereby reducing the risk of carry-over contamination and biosafety. This kit is applied to the LOAA dPCR equipment reported in the previous study, and it can overcome various limitations with this compact size and low equipment price. Thus, we suggest that the dPCR-based Dr. PCR™ Di20K COVID-19 Detection Kit is suitable for the COVID-19 point-of-care testing (POCT), which requires a rapid and efficient method. Correlation analysis of the qRT-PCR and dPCR assay using two different kits for the E and RdRp genes of SARS-CoV-2. A Correlation analysis for E gene of SARS-CoV-2 between qRT-PCR and dPCR assay was performed using the detection level results of in the 10 individual specimens with a high concentration of SARS-CoV-2. B Correlation analysis for the RdRp gene of SARS-CoV-2 between qRT-PCR and dPCR assay was performed using the detection level results of in the 10 individual specimens with a high concentration of SARS-CoV-2 COVID-19 pandemic: a new chapter in the history of infectious diseases Real-Q 2019-nCoV Detection Kit Instructions For Use (Ver. 1.1 COVID-19 pandemic-a focused review for clinicians Interpreting the COVID-19 test results: a guide for physiatrists Positive control synthesis method for COVID-19 diagnosis by one-step real-time RT-PCR Validation of real-time RT-PCR for detection of SARS-CoV-2 in the early stages of the COVID-19 outbreak in the Republic of Count on kappa Empirical evaluation of SUCRA-based treatment ranks in network meta-analysis: quantifying robustness using Cohen's kappa ? seq= 72625 & srchFr= & srchTo= & srchW ord= & srchTp= & itm_ seq_1= 0& itm_ seq_2= 0& multi_ itm_ seq= 0& compa ny_ cd= & compa ny_ nm= & page=1 Performance of the MagNA Pure 96 system for cytomegalovirus nucleic acid amplification testing in clinical samples A Comprehensive review of detection methods for SARS-CoV-2 Current and innovative methods for the diagnosis of COVID-19 infection (Review) Relationships between statistical measures of agreement: sensitivity, specificity and kappa Evaluation of seven commercial RT-PCR kits for COVID-19 testing in pooled clinical specimens Review of analytical performance of COVID-19 detection methods Introduction to regression analysis Point-of-care PCR assays for COVID-19 detection Mechanisms of SARS-CoV-2 transmission and pathogenesis Comparison of the new fully automated extraction platform eMAG to the MagNA PURE 96 and the well-established easyMAG for detection of common human respiratory viruses Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection COVID-19 Vaccine: a comprehensive status report The emergence of new SARS-CoV-2 variant (Omicron) and increasing calls for COVID-19 vaccine boosters-the debate continues Diagnostic evaluation of qRT-PCR-based kit and dPCR-based kit for COVID-19 Highaccuracy quantitative principle of a new compact digital PCR equipment: lab on an array Promising methods for detection of novel coronavirus SARS-CoV-2 COVID-19 antibody tests and their limitations Laboratory diagnosis of emerging human coronavirus infections-the state of the art COVID-19 pandemic-an African perspective COVID-19: Transmission, prevention, and potential therapeutic opportunities Protein-based lateral flow assays for COVID-19 detection Anxiety of Nurses to support Wuhan in fighting against COVID-19 epidemic and its correlation with work stress and self-efficacy PCR inhibition in qPCR, dPCR and MPS-mechanisms and solutions Guidelines on newly identified limitations of diagnostic tools for COVID-19 and consequences Recent advances and challenges of RT-PCR tests for the diagnosis of COVID-19 Sensitivity, specificity, and predictive values: foundations, pliabilities, and pitfalls in research and practice Main symptoms in patients presenting in the COVID-19 period Potential neurological symptoms of COVID-19 Rapid direct nucleic acid amplification test without RNA extraction for SARS-CoV-2 using a portable PCR thermocycler Virological assessment of hospitalized patients with COVID-2019 COVID-19 diagnosis-a review of current methods Ethical approval All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee.