key: cord-0701399-bckc74ux authors: Surasi, Krishna; Cummings, Kristin J.; Hanson, Carl; Morris, Mary Kate; Salas, Maria; Seftel, David; Ortiz, Liza; Thilakaratne, Ruwan; Stainken, Cameron; Wadford, Debra A. title: Effectiveness of Abbott BinaxNOW Rapid Antigen Test for Detection of SARS-CoV-2 Infections in Outbreak among Horse Racetrack Workers, California, USA date: 2021-11-03 journal: Emerg Infect Dis DOI: 10.3201/eid2711.211449 sha: 99e0223a41cc253348e9cf0ccc292570d993a479 doc_id: 701399 cord_uid: bckc74ux The Abbott BinaxNOW rapid antigen test is cheaper and faster than real-time reverse transcription PCR (rRT-PCR) for detecting severe acute respiratory syndrome coronavirus 2. We compared BinaxNOW with rRT-PCR in 769 paired specimens from 342 persons during a coronavirus disease outbreak among horse racetrack workers in California, USA. We found positive percent agreement was 43.3% (95% CI 34.6%–52.4%), negative percent agreement 100% (95% CI 99.4%–100%), positive predictive value 100% (95% CI 93.5%–100%), and negative predictive value 89.9% (95% CI 87.5%–92.0%). Among 127 rRT-PCR–positive specimens, the 55 with paired BinaxNOW-positive results had a lower mean cycle threshold than the 72 with paired BinaxNOW-negative results (17.8 vs. 28.5; p<0.001). Of 100 specimens with cycle threshold <30, a total of 51 resulted in positive virus isolation; 45 (88.2%) of those were BinaxNOW-positive. Our comparison supports immediate isolation for BinaxNOW-positive persons and confirmatory testing for negative persons. The Abbott BinaxNOW rapid antigen test is cheaper and faster than real-time reverse transcription PCR (rRT-PCR) for detecting severe acute respiratory syndrome coronavirus 2. We compared BinaxNOW with rRT-PCR in 769 paired specimens from 342 persons during a coronavirus disease outbreak among horse racetrack workers in California, USA. We found positive percent agreement was 43.3% (95% CI 34.6%-52.4%), negative percent agreement 100% (95% CI 99.4%-100%), positive predictive value 100% (95% CI 93.5%-100%), and negative predictive value 89.9% (95% CI 87.5%-92.0%). Among 127 rRT-PCR-positive specimens, the 55 with paired BinaxNOW-positive results had a lower mean cycle threshold than the 72 with paired BinaxNOW-negative results (17.8 vs. 28.5; p<0.001). Of 100 specimens with cycle threshold <30, a total of 51 resulted in positive virus isolation; 45 (88.2%) of those were BinaxNOWpositive. Our comparison supports immediate isolation for BinaxNOW-positive persons and confi rmatory testing for negative persons. duties (e.g., grooming, feeding) related to the basic care of the >1,100 horses stabled there. The outbreak was discovered by the contact tracing efforts of the local health department (LHD), the City of Berkeley Public Health Officer Unit. In response, the LHD ordered that all nonessential work activities (e.g., horse racing) be stopped until mass testing of all staff demonstrated no further transmission. The initial round of rRT-PCR testing (round 0) occurred on November [14] [15] 2020 , and identified 169 SARS-CoV-2-positive staff who were subsequently isolated. At this time, all staff were assumed to have been exposed. Those living onsite were moved to hotel rooms to quarantine, and those living offsite quarantined in their homes. No staff were permitted to return to onsite residence until the outbreak had ended. However, some quarantined employees were permitted to return to work if they were needed to perform duties related to essential care of the horses. Additional rounds of testing were needed to monitor ongoing transmission and determine when the outbreak had ended. The LHD decided to use BinaxNOW as a supplement to rRT-PCR to more quickly identify SARS-CoV-2-positive employees for isolation. This use provided an opportunity to assess the effectiveness of the BinaxNOW rapid antigen test in detecting SARS-CoV-2 infection in a nonhealthcare workplace outbreak. The purpose of this analysis is to compare BinaxNOW with rRT-PCR in paired specimens from persons during a COVID-19 outbreak among horse racetrack workers. These findings could inform testing protocols used to contain future outbreaks of COVID-19 in nonhealthcare workplaces. The facility, in collaboration with the LHD and the California Department of Public Health (CDPH) laboratory, conducted 6 rounds of serial testing of its staff with paired BinaxNOW rapid antigen and rRT-PCR tests during November 25-December 22 (rounds 1-6). Testing frequency was determined by the LHD and changed as the outbreak progressed. Each round was intended to test all staff who had not yet tested positive by BinaxNOW or rRT-PCR to continue identifying potentially infectious persons. Staff who tested positive by either BinaxNOW or rRT-PCR were isolated and excluded from further testing. All specimen collection and antigen testing occurred outdoors in the parking lot of the facility. On the day of testing, a facility administrative employee conducted registration and collected demographic data, including self-reported race and ethnicity. Symptom information was elicited by asking staff if they were experiencing any COVID symptoms, such as fever, headache, or loss of taste. Bilateral anterior nasal swab specimens were collected by either the racetrack physician or one of the racetrack veterinarians trained in collection procedures. A first swab specimen was used for onsite BinaxNOW testing; a second swab specimen was placed in viral transport medium and chilled on ice packs before transport to the CDPH laboratory for rRT-PCR testing 24-72 hours after collection. All specimens in viral transport medium were frozen at -70°C within 12 hours of delivery to the laboratory. BinaxNOW test results were interpreted immediately at the 15-minute read time by the racetrack physician in accordance with the test kit instructions, along with the updated scoring criteria described by Pilarowski et al. (5) , which indicates that bands are scored as positive only if they extend across the full width of the strip, irrespective of the intensity of the band. Because Bi-naxNOW testing was not performed for round 0, those 169 rRT-PCR-positive specimens were not included in this analysis. For rRT-PCR, we isolated and purified viral nucleic acid (NA) from the swab specimens by using the KingFisher Flex Purification System and the MagMAX Viral/Pathogen Nucleic Acid Isolation Kit (ThermoFisher Scientific, https://www.thermofisher.com). We performed rRT-PCR by using the ThermoFisher TaqPath COVID-19 Combo Kit, which targets 3 SARS-CoV-2 viral regions (nucleocapsid protein gene, spike protein gene, and open reading frame 1ab), and the Applied Biosystems 7500 Fast Dx Real-Time PCR Instrument (Thermo-Fisher Scientific), according to the manufacturer's instructions. Real-time RT-PCR-positive specimens with C t <30 were also cultured for SARS-CoV-2 at CDPH in a Biosafety Level 3 laboratory. For cultures, 200 µL of patient specimen was diluted 1:1 with diluent containing 0.75% bovine serum albumin, and 50 µL was added to 8 replicate wells in a 96-well plate containing confluent Vero-81 cells at 37°C with 5% CO 2 . After 1 h, the inoculum was removed and 200 µL of minimum essential medium containing 5% fetal bovine serum and antibiotics was added to each well. Cells were monitored for cytopathic effect. Cells with positive cytopathic effect were tested by rRT-PCR to confirm presence of SARS-CoV-2. Cells with no cytopathic effect or negative rRT-PCR results were passaged after 7 d onto fresh confluent Vero-81 and monitored for an additional 7 d before performing rRT-PCR again. Viral replication in these specimens was defined as a decrease in C t over the culture period. We used the paired BinaxNOW and rRT-PCR results to calculate the BinaxNOW PPA, NPA, negative predictive value (NPV), and positive predictive value (PPV), using C t <37 to define rRT-PCR-positive specimens. As described in Pilarowski et al. (5) , we also calculated performance by using C t <30 to define rRT-PCR-positive specimens. The exact binomial method was used to calculate 95% CIs. Comparison of mean C t was performed using the Welch t-test. We performed statistical analyses using R version 4.0.1 (R Foundation for Statistical Computing, https:// www.r-project.org). This activity was reviewed by the Centers for Disease Control and Prevention (CDC) and was conducted consistent with applicable federal law and CDC policy (45 C.F.R. part 46, 21 C.F.R. part 56; 42 U.S.C. §241(d); 5 U.S.C. §552a; 44 U.S.C. §3501 et seq.). In addition, this activity was conducted as part of a COVID-19 project determined to be nonresearch by the California Health and Human Services Agency's Committee for the Protection of Human Subjects. Including testing performed in round 0 and results reported by outside laboratories from staff seeking testing on their own, the cumulative incidence over the course of the outbreak in the entire staff was 62.3% (351/563). A total of 342 different staff participated in testing rounds 1 through 6. These persons ranged in age from 18 to 92 years (median 52 years). Self-reported race and ethnicity produced cell sizes that are too small to report, so only Hispanic ethnicity is presented in this study. Most staff identified as Hispanic (62.0%) ( Table 1 ). Symptoms were reported by 11 different persons at the time of testing, which accounted for 11/769 (1.4%) of collected paired specimens. A total of 6 persons were hospitalized, and 1 of those patients died. The number of staff tested in each round, which varied because of attrition and exclusion of SARS-CoV-2-positive staff from further testing, ranged from 333 persons (round 1) to 57 persons (round 4). The number of rRT-PCR-positive results in each round ranged from 98 (round 1) to 0 (round 4) ( Table 2 ). In total, 769 valid, paired rRT-PCR and Bi-naxNOW antigen test results were reported and analyzed. Among all paired testing rounds with rRT-PCR, BinaxNOW produced these results when rRT-PCR tests with C t <37 were considered positive: PPA, 43.3% (95% CI 34.6%-52.4%); NPA, 100% (95% CI 99.4%-100.0%); PPV, 100.0% (95% CI 93.5%-100.0%); and NPV, 89.9% (95% CI 87.5%-92.0%). When only rRT-PCR tests with C t <30 were considered positive, BinaxNOW produced these results: PPA, 55.6% (95% CI 45.2%-65.6%); NPA, 100% (95% CI 99.5%-100%), PPV, 100.0% (95% CI 93.5%-100%); and NPV, 93.8% (95% CI 91.8%-95.5%) ( Table 3) . Of 127 rRT-PCR-positive specimens, BinaxNOW detected 55, did not detect 72 (44 specimens with C t <30, 5 specimens with C t <20, and 6 specimens with positive viral cultures), and produced no false-positive results (Table 3) . Among rRT-PCR-positive specimens, those with paired BinaxNOW-positive results had a lower mean C t (17.8) than those with paired Bi-naxNOW-negative results (28.5) (p < 0.001). No rRT-PCR-positive results with a C t >29.4 were detected by BinaxNOW (Figure 1) . In dual-positive pairs, the median time between rRT-PCR specimen collection date and results reported date was 4 days (range 1-6 days). For BinaxNOW false-negative pairs, the median time between rRT-PCR specimen collection date and results reported date was 5 days (range 1-7 days). In contrast, the 15-minute read time of the BinaxNOW antigen test kit provided results to the facility and LHD the same day as testing. Of the 127 rRT-PCR-positive specimens, we attempted virus isolation and culture for all 100 specimens with C t <30. Of those specimens, 51 resulted in positive virus isolation. Of those culture-positive specimens, 45 (88.2%) were BinaxNOW-positive (Table 4 ; Figure 2 ). The mean C t of culture-positive specimens (17.4) was significantly lower than culturenegative specimens (25.5) (p<0.001). In the setting of a nonhealthcare workplace outbreak of COVID-19 with high attack rate (62.3%), we found that BinaxNOW was a useful adjunct to rRT-PCR testing. BinaxNOW showed NPA and PPV of 100%. A total of 55 participants were concordantly identified as positive by BinaxNOW and rRT-PCR, and no false-positive BinaxNOW results were noted. This low false-positive rate is consistent with results from Pilarowski et al. (5) that established the updated BinaxNOW card-reading technique used by the racetrack physician in this outbreak. Results of BinaxNOW testing were available the same day, which enabled more rapid identification of infected workers for isolation than reliance on rRT-PCR alone. Negative BinaxNOW results were less concordant with rRT-PCR results. The PPA of BinaxNOW was 43.0% and the NPV was 89.9%. Real-time RT-PCR confirmation of BinaxNOW negative results identified 72 additional positive specimens. The median time between rRT-PCR specimen collection date and results reported date for these BinaxNOW falsenegative specimens was 5 days (range 1-7 days). Although C t cannot be used to define viral load or infectivity of a given person, C t is inversely related to the amount of target genetic material present in the specimen (11) . Therefore, the significantly lower mean C t for true-positive BinaxNOW specimens (17.8) compared with false-negative BinaxNOW specimens (28.5) indicates that more viral genetic material was present in those specimens. BinaxNOW demonstrated better concordance with positive viral culture results (88.2%) than with positive rRT-PCR results (43.3%). Positive viral culture is further evidence of the presence of infectious virus, so these findings might indicate that some BinaxNOW false-negative participants were not infectious at the time of specimen collection (i.e., they had low viral RNA load at the beginning or end of their infection trajectory) (12) . Numerous factors can affect the outcome of a viral culture; therefore, negative culture results do not necessarily mean that no viable virus was present in those specimens, nor that the participants from whom those specimens were collected were not infectious at the time of specimen collection. With serial BinaxNOW testing, some of the persons with discordant paired results could have tested positive with subsequent BinaxNOW testing. Further studies are needed to determine whether serial rapid antigen testing alone can identify infectious persons as efficiently as rRT-PCR alone or a combination of rRT-PCR and rapid antigen testing (13). The first limitation of our study is that, although other studies have demonstrated differential BinaxNOW test performance in symptomatic and asymptomatic persons (3,6-8), we were unable to examine test performance by symptom status, because symptom reporting might not have been reliable. At the time of specimen collection, only 11 persons reported symptoms to the facility administrative employee registering them for testing. This number conflicts with data previously collected from the racetrack physician as part of a prospective cohort drug trial on this same population which, out of an enrolled cohort of 113 BinaxNOWpositive staff, identified 60 (53%) persons who were symptomatic at the time of testing (14) . This discrepancy might have resulted from staff feeling less comfortable discussing symptoms with the administrative employee versus the racetrack physician or it could be associated with the incomplete list of COVID-19 symptoms in the administrative employee's question. It might also reflect a language barrier, because the question about symptoms was asked only in English by the administrative employee. According to onsite interactions with staff and reports from racetrack leadership, many staff were native Spanish speakers, although this language difference was not quantified. Second, the BinaxNOW tests may have been performed in ambient temperatures below the manufacturer's recommended range. The BinaxNOW test kit instructions recommend that all test components be at room temperature (15°C-30°C) before use; the mean daily minimum and maximum air temperature recordings from a nearby National Oceanic and Atmospheric Administration weather station in Richmond, CA, on testing days were 7.9°C and 15.1°C (15) . Performing BinaxNOW tests in the recommended temperature range might have improved performance. Third, some missing data limit this analysis from encompassing the entire outbreak. The first mass testing dates (round 0) only used rRT-PCR testing, so no comparison with BinaxNOW was possible. Furthermore, each round of testing was intended to capture all staff who had not yet tested positive; however, participant attrition occurred between testing rounds. We attribute this attrition to the logistical obstacles of staff getting to the testing site or to staff leaving their jobs during the outbreak. More complete paired-testing data could have provided better insight as to the usefulness of rapid antigen testing when used for the entire duration of an outbreak. Our results support considering BinaxNOWpositive employees as infectious without waiting for rRT-PCR confirmation. The rapid turnaround time and high PPV of BinaxNOW enabled some SARS-CoV-2-positive employees to be identified and isolated faster than if rRT-PCR had been used alone. In outbreak situations in which access to laboratory rRT-PCR services is limited, it might be reasonable to act on BinaxNOW-positive results and forgo rRT-PCR confirmation. In contrast, our findings suggest that BinaxNOW negative results in an outbreak investigation should be confirmed with rRT-PCR, because false negatives do occur. Our results indicate that BinaxNOW performs better at identifying rRT-PCR-positive specimens with lower C t (suggestive of higher viral loads) and positive viral cultures, although these factors are not precise proxies for infectiousness. Real-time RT-PCR remains a more sensitive test for identifying persons that might be infectious, and our results support the current recommendation that rRT-PCR (or another nucleic acid amplification test) should be used in outbreak situations to confirm BinaxNOW-negative results (2). Clinical discretion informed by COVID-19 incidence in the relevant population, as well as individual exposure history and symptoms, should be used to determine whether to quarantine persons who test negative for SARS-CoV-2 by BinaxNOW but are awaiting results of rRT-PCR testing (16). Emerging Infectious Diseases • www.cdc.gov/eid • Vol. 27, No. 11, November 2021 Food and Drug Administration Centers for Disease Control and Prevention. Interim guidance for antigen testing for SARS-CoV-2 Performance of the BinaxNOW COVID-19 antigen card test relative to the SARS-CoV-2 real-time reverse transcriptase polymerase chain reaction assay among symptomatic and asymptomatic healthcare employees Performance characteristics of BinaxNOW COVID-19 antigen card for screening asymptomatic individuals in a university setting Performance characteristics of a rapid severe acute respiratory syndrome coronavirus 2 antigen detection assay at a public plaza testing site in San Francisco Field performance and public health response using the BinaxNOW TM Rapid SARS-CoV-2 antigen detection assay during community-based testing Performance and implementation evaluation of the Abbott BinaxNOW rapid antigen test in a high-throughput drive-through community testing site in Massachusetts Evaluation of Abbott BinaxNOW rapid antigen test for SARS-CoV-2 infection at two community-based testing sites-Pima County COVID-19 as an occupational disease Update: COVID-19 among workers in meat and poultry processing facilities-United States C t values from SARS-CoV-2 diagnostic PCR assays should not be used as direct estimates of viral load Interpreting diagnostic tests for SARS-CoV-2 Rethinking Covid-19 test sensitivity-a strategy for containment Prospective cohort of fl uvoxamine for early treatment of coronavirus disease 19. Open Forum Infect Dis Centers for Disease Control and Prevention. Interim guidance for SARS-CoV-2 testing in non-healthcare workplaces Unidentifi ed cyst-forming sporozoon causing encephalomyelitis and myositis in dogs Review of Neospora caninum and neosporosis in animals Detection of immunoglobulin G antibodies to Neospora caninum in humans: high seropositivity rates in patients who are infected by human immunodefi ciency virus or have neurological disorders We thank Lisa B. Hernandez, James Allard, Beimnet Taye, the California Department of Public Health Viral and Rickettsial Disease Laboratory staff, and the racetrack staff described in this report. From the neo-(Latin, "new") + spora (Greek, "seed") and canis (Latin, "dog"), Neospora caninum is a sporozoan parasite that was fi rst described in 1984. It is a major pathogen of cattle and dogs but can also infect horses, goats, sheep, and deer. Antibodies to N. caninum have been found in humans, predominantly in those with HIV infection, although the role of this parasite in causing or exacerbating illness is unclear.Sources: