key: cord-0700408-3eppoqo2 authors: Guan, Lidong; Yu, Yuanling; Wu, Xiaohong; Nie, Jianhui; Zhang, Jun; Wang, Zejun; Li, Na; Shi, Rui; Zhao, Hui; Chen, Hongbo; Luo, Chunxia; Hu, Yaling; Wang, Youchun; Huang, Weijin; Xu, Miao; Hou, Jifeng title: The first Chinese national standards for SARS-CoV-2 neutralizing antibody date: 2021-05-19 journal: Vaccine DOI: 10.1016/j.vaccine.2021.05.047 sha: 5257ddb85d080ce3d9bbaad06b14fd67f96f8b50 doc_id: 700408 cord_uid: 3eppoqo2 In order to meet the domestic urgent needs of evaluating the immunogenicity of vaccines and the potency testing of therapeutic antibody products against coronavirus disease 2019 (COVID-19), the first Chinese national standards for SARS-CoV-2 neutralizing antibody were established. The potency and stability of the candidate standards were determined by neutralization assay and accelerated degradation study. The stability studies showed that the standards were stable in the short-term. The collaborative study showed that the candidate standards could reduce the variations in neutralization titers between labs and thus improve comparability of neutralizing antibody measurements. Sample 22 has been approved by the Biological Product Reference Standards Sub-Committee of the National Drug Reference Standards Committee as the first Chinese National Standard for Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2) neutralizing antibody, with an assigned potency of 1,000 units per milliliter (U/ml). This standard will contribute to the standardized assessment of the quality and efficacy of vaccines and therapeutics for COVID-19 in China. On December 31, 2019, unexplained pneumonia (later designated as coronavirus disease 2019, broke out in Wuhan, China [1] . The causative agent of COVID-19, Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2), is highly pathogenic and infectious, and can be transmitted through contact, droplets, aerosols, and fecal-orally [2] . COVID-19 has now become a global pandemic, threatening the public health and economic development of countries across the world. As of October 28, 2020, more than 43 million cases of COVID-19 have been diagnosed and over one million people have died of the disease worldwide. Thus, vaccines and therapeutics for COVID-19 are urgently needed. Currently, the World Health Organization (WHO) and world governments are working together to accelerate the development of prophylactics and therapeutics to counter this pandemic [3, 4] . However, different from other respiratory diseases caused by coronaviruses, such as Severe Acute Respiratory Syndrome (SARS) and Middle East Respiratory Syndrome (MERS), COVID-19 is a brand-new disease and there are currently no wholly effective prevention and treatment countermeasures. Preventive vaccines and therapeutic neutralizing antibodies are important means for the prevention and control of COVID-19, and are the key research objectives of institutions and pharmaceutical companies looking to help control the pandemic [5] [6] [7] [8] [9] [10] [11] [12] . Neutralizing antibodies can inactivate the SARS-CoV-2 virus, presumably by intercepting the virus before it attaches to the surface of the target cell. The level of neutralizing antibodies is a key 6 indicator for assessing the immunogenicity of vaccines and the potency of therapeutics, and it must be determined accurately. By October 29, 2020, 13 vaccines and one antibody product against COVID-19 had entered clinical phases in China [13] . Yet, there are no standardized methods to measure the neutralizing antibody against SARS-CoV-2. These relevant differences in test protocols have resulted in the incomparability of assay data between labs and products. Standardized neutralization assay methods depend on standards for neutralizing antibodies. In addition, standard is an indispensable tool for controlling the quality of medicines in drug inspection. The standards for SARS-CoV-2 neutralizing antibody are thus urgently needed. In this study, the establishment of the first national standards for neutralizing antibodies to SARS-CoV-2 are described. The standards were produced from plasma samples from convalescent COVID-19 patients in China. This collaborative study was organized by the National Institutes for Food and Drug Control (NIFDC). Eleven labs, including national research labs, national control labs, and manufacturers of vaccines and antibody products engaged in this study. The establishment of these national standards aimed to standardize the methods for neutralization assays, ensure the accuracy and comparability of neutralizing antibody titers between different labs and products, and effectively control the quality of vaccines and therapeutics for COVID-19. Two plasma samples from COVID-19 convalescent patients, sample 22, sample 77 were generously provided by Boya Bio-pharmaceutical Group Co., Ltd. and Sinopharm Wuhan Plasma-derived Biotherapies Co., Ltd.. Written informed consents were obtained from all the volunteers. Two plasma samples from convalescent patients were first tested for hepatitis B virus deoxyribonucleic acid (HBV DNA), hepatitis C virus ribonucleic acid (HCV RNA), human immunodeficiency virus (HIV) RNA, and SARS-CoV-2 RNA, as well as the corresponding Hepatitis B surface antigen (HBsAg), HIV-1 / HIV-2 antibody, HCV antibody, and syphilis antibody. Meanwhile, the plasma was inactivated at 56°C for 30 minutes. The neutralizing antibody titer of convalescent COVID-19 patient plasma was detected by a pseudo virus neutralization assay as described previously [14, 15] . In brief, the serial dilutions of the test samples (six dilutions in a 3-fold step-wise manner) were incubated with pseudo virus for one hour at 37°C, together with the virus control and cell control wells. Then, freshly trypsinized Huh-7 cells (2 × 10 4 cells) were added to each well. Following 24 hours of incubation in a 5% carbon dioxide (CO 2 ) environment at 37°C, the relative light unit (RLU) was detected according to the instruction manual provided by PerkinElmer (Waltham, MA). The neutralization titers were defined as 50% maximal inhibitory dilutions and calculated with the Reed-Muench method. Inhibition percentage was calculated as the following: The plasma with higher titer neutralizing antibodies was selected to prepare candidate standards for this study. After being inactivated, the plasma was placed in the biosafety cabinet until it reached room temperature, and then kept at 4°C overnight. The next day, the plasma samples were centrifuged at 5,000 revolutions per minute (rpm) for 15 minutes. The supernatant was separated and packed into 0.5 milliliter (ml) screw cap tubes, with each tube containing 100 microliters (ul), which was then sealed and stored at −30°C. A total of five samples were provided to participants:  Sample 55 was human plasma, which was derived from a large mixture of plasma from healthy donors. The following eleven labs engaged in the collaborative study: the Institute of The NIFDC organized this collaborative study. The eleven labs mentioned above participated in the study. Live virus-and pseudo virus-based neutralization assays were used to detect the neutralization titer against SARS-CoV-2 ( Table 1 ). The pseudo virus neutralization assay was performed according to the method established by Nie et al. [15] . The live virus neutralization assay was conducted using participant's established methods. For each sample, at least three independent assays were performed. In each assay, a fresh tube of sample was used and more than six dilutions for each sample was required. Due to the inadequate time and plasma with high titer neutralizing antibody against SARS-CoV-2, we did not conduct long-term stability studies on Sample 22, and only did partial temperature acceleration tests in this study. Sample 22 was separately stored at −30°C, 4°C, and 25°C, and the titers of neutralizing antibody were determined on days 7, 11, 18, 27, and 33 by pseudo virus neutralization assay. The pseudotyped viruses corresponding to the SARS-CoV-2 variants B.1.1.7, B.1.351 and P.1 were constructed using the methods reported in our previous papers [14, 15] . The pseudo-virus neutralization assay was performed according to the method established by Nie et al. [15] . The sample ED 50 (median effective dilution) was calculated using the Reed-Muench method [15] . The neutralization titers in the collaborative study samples were assessed by neutralization assays based on pseudo virus or live virus. For the pseudo virus-based neutralization assay, the neutralization titer was calculated by Reed-Muench method based on the results of the neutralization inhibition rate [15] . For the live virus-based neutralization assay, one lab detected the virus by plague staining, one lab detected absorbance after staining with crystal violet, and three labs detected cytopathic effect (CPE) ( Table 1 ). The sample neutralization titer was calculated using the Reed-Muench method. The Reed-Muench method has been widely used in China to calculate the neutralization titers of antibody products and vaccine-elicited sera. The geometric mean (GM) of at least three independent assays performed in order to calculate the laboratory mean of each sample. Overall mean potencies were calculated as the geometric means of the laboratory means. The variations in the neutralizing titer between assays within labs and between labs were assessed using geometric coefficients of variation (GCV), with the formula GCV% = (e ^s-1) × 100% where s is the standard deviation of the lnN transformed results. Before statistical analysis, the natural logarithm of potencies was transformed to fit normal distribution [16] . To screen plasma with high neutralizing potency, we detected the neutralizing antibody against SARS-CoV-2 in two plasma samples from Boya Bio-pharmaceutical Group Co., Ltd. and Sinopharm Wuhan Plasma-derived Biotherapies Co., Ltd. The geometric mean values of the neutralizing antibody titers in the two samples were 1307 and 136, respectively. The BOYA sample (No. 22), with a higher neutralizing antibody titer, was selected as the candidate national standard for SARS-CoV-2 neutralization antibodies. Ten of the eleven labs returned the results of the pseudo virus neutralization assay, which are listed in the Table S1 . Four labs returned live virus neutralization assay results, which are shown in the Table S2 . Among them, both Lab JS and Lab ZY returned one set of pseudo virus neutralization assay results and one set of live virus neutralization assay results. Lab WS returned one set of pseudo virus neutralization assay results and two sets of results from two different live virus neutralization assays. Sample 55 was a negative control; the results of different labs were consistent and will not be analyzed in the future study. The geometric mean potencies for samples in the pseudo virus neutralization assay are shown in Table 2 and Figure 1 . Because Sample 44 in Labs ZW and ZA had data for only one valid assay, the intra-lab (between replicate assay) variability was not calculated. Except for Sample 77 in Lab ZW (GCV of 324%), the intra-lab coefficient of variation of each sample was less than 100%. As shown in Table 2 , Lab ZW had significantly higher potency estimates for each sample than that of other labs. The overall geometric mean estimates for Samples 22, 44, 77, and 99 were 1,938, 3,973, 162, and 2,064, respectively, the pooled GCV between labs for Samples 22, 44, 77, and 99 were 63%, 56%, 172%, and 88%, respectively ( Table 2 ). If Sample 22 was set as the standard and assigned a potency of 1,000 units per milliliter (U/ml), the high potency estimates in Lab ZW was corrected, and the overall GCV between labs for Samples 44, 77, and 99 decreased to 23%, 106%, and 48%, respectively (Table 3) . The geometric mean estimates for samples in the live virus-based neutralization assay are listed in Table 4 . Lab WS returned two sets of assay data, which were based on the plaque reduction neutralization test (PRNT) and CPE. The geometric mean potencies based on these two methods were quite different. The geometric mean potencies of Lab ZY and Lab WS based on the CPE were relatively close, but were quite different from the potencies of Lab BK, which also used the CPE method. Lab JS's virus challenge strain, cells, and results-detection methods were different from the other three labs, and its geometric mean potencies were lower than those of other labs. Since Sample 77 in Lab JS had no valid assay data, the geometric mean potency and intra-lab variability was not calculated. As shown in Table 4 , the intra-lab GCVs ranged from 0 to 92% depending on the samples, which were significantly lower than the GCVs between labs. The GCV between labs for Samples 22, 44, 77, and 99 was 360%, 129%, 266%, and 146%, respectively. If Sample 22 was set as the standard and assigned a potency of 1,000 U/ml, the GCV between the labs for Samples 44, 77, and 99 decreased to 107%, 18%, and 90%, respectively (Table 5) . It can be seen from the previous assay data that due to the differences in assay method, virus challenge strain, and cells between the live virus-and pseudo virus-based neutralization assays, the neutralizing antibody titers of the same sample were quite different ( Table 2 and Table 4 ). We then compared the samples potency estimates relative to Sample 22 obtained from the pseudo virus neutralization assay with the live virus neutralization assay. Although the samples' potencies against pseudo virus were lower than those against live SARS-CoV-2 after standardization, there was a high correlation between the two assays (R 2 =0.9781) (Figure 2 ). Our previous results showed that the geometric mean of the neutralizing antibody titer of Sample 22 was 1,460 (95% confidence interval 1,112-1,918) . The results of this accelerated test showed that within one month, whether Sample 22 was stored at −30°C, 4°C, or 25°C, the changes in the titer of the neutralizing antibodies were within the 95% confidence interval. There was no significant loss of neutralization activity at 4 °C and 25 °C relative to the −30 °C baseline for Sample 22 (Table 6 ). These results indicated that Sample 22 has good short-time stability. Samples will be tested yearly to assess long-term stability. Due to the high pathogenicity and infectivity of SARS-CoV-2, COVID-19 has become a global pandemic, causing tremendous devastation to the world. Currently, there are no approved effective anti-viral products or vaccines against SARS-CoV-2. Accurate determination of neutralizing antibodies against SARS-CoV-2 is critical for evaluating the immunogenicity of vaccines, assessing the potency of antibody products, and establishing quality control standards for vaccines and antibody products. Both the live virus-based neutralization assay, such as PRNT and CPE, and pseudo virus-based neutralization assays were used to detect neutralization antibody titers [5, 7, [17] [18] [19] . Because different labs use different neutralization assay methods, or the neutralization assay methods are the same but the virus challenge strains, cells, and detection methods are different, the assay data between different labs and various products are not comparable. In order to standardize the virus neutralization method and ensure the accuracy and comparability of assay data, this study aimed to develop national standards for SARS-CoV-2 neutralizing antibodies. To assess the suitability of candidate national standard virus neutralization assays, the collaborative calibration of five samples was conducted in eleven labs across China. In this collaborative study, although the method of pseudo virus neutralization assay was unified, there were differences in the testing conditions, cell status, and personal operations in various labs, which affected the consistency of results between labs (Table 2 ). In the live virus neutralization assay, due to the differences in virus strains and cells, as well as methods of observing the results, the GCVs across labs were higher (Table 4 ). However, once the values were expressed as relative potencies against the candidate standards, the variations in neutralizing titer between labs were significantly reduced in both live virus-and pseudo virus-based neutralization assays (Table 3 and Table 5 ). These results suggest that the application of standards could reduce discrepancies and improve comparability between assays performed in different labs. Although the samples' potencies against pseudo virus were lower than those against live SARS-CoV-2 after standardization, there was a high correlation between the two assays ( Figure 2 ). Due to the limited number of samples in this test, further verification is needed in the future study. Consistent with our results, Li et al. reported a strong correlation between the neutralization antibody titers generated by pseudo virus and live virus systems [20] . Additionally, due to time constraints, we only did a short-term stability study, which showed that the candidate standard sample was stable in the short term (Table 6 ). However, more stability data are needed to establish a long-term stability profile. Taken together, Sample 22 is recommended as the national standard for the SARS-CoV-2 neutralizing antibody. The establishment of this national standard would ensure the accuracy and comparability of neutralizing antibody detection and facilitate the assessment of vaccine immunogenicity and antibody products potency. The collaborative study of the first Chinese national standard for SARS-CoV-2 neutralizing antibody only used the methods of detecting the neutralizing antibody titer, and did not include the methods of detecting the binding antibody such as ELISA. The neutralization potency of the first Chinese national standard for SARS-CoV-2 neutralizing antibody was affected by spike substitutions found in variants of concern (VOC). Compared with the Wuhan-1 reference strain (Wild Type), the neutralizing titer of the national standard against B.1.1.7 decreased by 1.9-fold, and the neutralizing titer against B.1.351 and P.1 reduced by more than 10-fold ( Figure S1 ). In the future, we will establish the second-generation Chinese national standards for SARS-CoV-2 neutralizing antibody that can effectively neutralize VOC. Standardization, Geneva, 9-10 December 2020. ☒ The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. ☐The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: A Novel Coronavirus from Patients with Pneumonia in China Transmission and prevention of SARS-CoV-2 WHO International Health Regulations Emergency Committee for the COVID-19 outbreak Novel Coronavirus (2019-nCoV): Strategic Preparedness and Response Plan. Draft as of 3 A human neutralizing antibody targets the receptor-binding site of SARS-CoV-2 Development of an inactivated vaccine candidate for SARS-CoV-2 A Thermostable mRNA Vaccine against COVID-19 A SARS-CoV-2 mRNA Vaccine -Preliminary Report Development of an Inactivated Vaccine Candidate, BBIBP-CorV, with Potent Protection against SARS-CoV-2. Cell DNA vaccine protection against SARS-CoV-2 in rhesus macaques ChAdOx1 nCoV-19 vaccine prevents SARS-CoV-2 pneumonia in rhesus macaques Single-shot Ad26 vaccine protects against SARS-CoV-2 in rhesus macaques Keeping track of the SARS-CoV-2 vaccine pipeline Establishment and validation of a pseudovirus neutralization assay for SARS-CoV-2. Emerg Microbes Infect Quantification of SARS-CoV-2 neutralizing antibody by a pseudotyped virus-based assay Yao pin jian du yu jian ding zhong de tong ji xue ying yong Immunogenicity and safety of a recombinant adenovirus type-5-vectored COVID-19 vaccine in healthy adults aged 18 years or older: a randomised, double-blind, placebo-controlled, phase 2 trial. The Lancet Safety, tolerability, and immunogenicity of an inactivated SARS-CoV-2 vaccine in healthy adults aged 18-59 years: a randomised, double-blind, placebo-controlled, phase 1/2 clinical trial. The Lancet Infectious Diseases Effect of an Inactivated Vaccine Against SARS-CoV-2 on Safety and Immunogenicity Outcomes: Interim Analysis of 2 Establishment of replication-competent vesicular stomatitis virus-based recombinant viruses suitable for SARS-CoV-2 entry and neutralization assays World Health Organization. Establishment of the WHO International Standard and Reference Panel for anti-SARS-CoV-2 antibody Abbreviations: GM, geometric mean GCV, geometric coefficient of variation We thank Boya Bio-pharmaceutical Group Co., Ltd. and Sinopharm Wuhan Plasma-derived Biotherapies Co., Ltd. for kindly providing human plasma samples.We thank Prof. Changgui Li (NIFDC) for kindly providing rabbit antiserum. We thank NIBSC for kindly providing international collaboration study samples. 18 The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Abbreviations: NC, not calculated; GM, geometric mean; GCV, geometric coefficient of variation.