key: cord-0699294-2rhf1tji authors: Bozek, John S.; Hayanga, Heather K.; Sengupta, Partho; Khan, Mir Ali Abbas; Ellison, Matthew B. title: Transesophageal echocardiography probe cover: implementation of a cross-contamination containment strategy during the COVID-19 pandemic date: 2021-02-19 journal: Braz J Anesthesiol DOI: 10.1016/j.bjane.2020.12.023 sha: 368bbd0c03eed381592b698f1a0de38296563691 doc_id: 699294 cord_uid: 2rhf1tji nan This statement reaffirms the idea that the TEE examination is an aerosolizing procedure with airborne precautions recommended for COVID positive or high-risk patients. [2] In the perioperative environment, the TEE probe is intermittently and frequently manipulated over a period of several hours during the surgical procedure, resulting in the possible contamination of multiple operating room surfaces. Several studies have demonstrated that anesthesiologists may be responsible for the possible spread of pathogens from the patient to the operating room environment, which may result in cross-contamination between providers and patients. [3, 4] The technique utilized for covering each TEE probe at our institution is described below. After inserting a clean TEE probe tip into the open end of a standard ultrasound probe cover and placing a rubber band above the wheel to secure the cover to the probe, we cut the opposite (closed) end of the probe cover with sterile scissors. We verify the cut portion of the probe cover is neat and tear-free, and then anchor it with a rubber band onto a bite block (Fig. 1 ). The TEE probe is advanced beyond the bite block into the esophagus. The bite block is then positioned in the patient's mouth. Because the exposed (contaminated) portion of the TEE J o u r n a l P r e -p r o o f probe remains within the probe cover, direct contact with secretions and potential for inadvertent spread to the operating room environment is minimized. As elective TEE cases have resumed, we have continued to use an ultrasound probe cover (Fig. 1 ) as a protective barrier on each TEE probe and for many examinations. Although this method was developed independently at our institution, a similar method was proposed by Dr. Jain, an anesthesiologist from the Medical College of Georgia. [5] We believe that this is a viable technique to both perform a high quality echocardiographic exam and to prevent exposure of the provider performing the TEE to oral secretions from the patient. The authors declare no conflicts of interest. ASE Statement on Protection of Patients and Echocardiography Service Providers During the 2019 Novel Coronavirus Outbreak: Endorsed by the American College of Cardiology ASE Statement on the Reintroduction of Echocardiographic Services during the COVID-19 Pandemic Transmission of pathogenic bacterial organisms in the anesthesia work area The use of a novel technology to study dynamics of pathogen transmission in the operating room Preventing Contamination During Transesophageal Echocardiography in the Face