key: cord-0693892-yv3hiw2z authors: Pietsch, U.; Knapp, J.; Wenzel, V.; Lischke, V.; Albrecht, R. title: Mechanische CPR (AutoPulse™) in Bauchlage, machbar? date: 2020-09-23 journal: Anaesthesist DOI: 10.1007/s00101-020-00851-1 sha: 25880a25cf3b892ccda66434ff380d0cb1f876ba doc_id: 693892 cord_uid: yv3hiw2z BACKGROUND: Due to SARS-CoV‑2 respiratory failure, prone positioning of patients with respiratory and hemodynamic instability has become a frequent intervention in intensive care units (ICUs), and even in patients undergoing transfer in an ambulance or helicopter. It has become increasingly important how to perform safe and effective CPR in prone position, achieving both an optimal outcome for the patient and optimal protection of staff from infection. MATERIALS AND METHODS: We conducted feasibility tests to assess the effects of CPR with an automatic load-distributing band (AutoPulse™) in prone position and discussed different aspects of mechanical chest compression (mCPR) in prone position. RESULTS: In supine position, AutoPulse™ generated a constant pressure depth of 3cm at a frequency of 84/min. In prone position, AutoPulse™ generated a constant pressure depth of 2.6cm at a frequency of 84/min. CONCLUSION: We found mCPR to be feasible in manikins in both prone and supine positions. Während der SARS-CoV-2-Pandemie ist die Bauchlagerung für Patienten mit schwerem akutem Atemnotsyndrom (ARDS) zu einem etablierten Therapieverfahren auf vielen Intensivstationen und teilweise auch während des Transportes mittels Notarztwagen oder Rettungshubschrauber im Rahmen eines Interhospitaltransfers geworden [1, 2] . Es stellt sich vermehrt die Frage, wie im Rahmen eines Kreislaufstillstandes bei diesen schwersterkrankten Patienten in Bauchlage vorzugehen ist, um einerseits eine qualitativ hochwertige kardiopulmonale Reanimation (CPR) sicherzustellen und gleichzeitig ein größtmögliches Maß an Sicherheit und Schutz für das medizinische Personal zu garantieren. Es existieren mittlerweile (einige) wenige Der AutoPulse ® ist ein verbreitetes mechanisches Reanimationsgerät, welches sich jedoch aufgrund der Thoraxkompressionstechnik ("automatic loaddistributing band") außerhalb der Leitlinienempfehlungen des ERC und der AHA bewegt (Kompressionsfrequenz 80 ± 5/min, Kompressionstiefe ca. 20 % der a.-p.-Thorax-Höhe) und damit sowohl im Modell als auch am Patienten schwierig mit klassischen objektivierbaren Zielwerten, wie Drucktiefe und Frequenz der CPR, vergleichbar ist [5] . Es ist zu bedenken, dass die mechanische Drucktiefe nicht gleichzusetzen ist mit dem generierten Druck in den intrathorakalen Gefäßen und der kardialen Auswurffraktion, welches die Effektivität des AutoPulse trotz geringerer Frequenz und Drucktiefe begründet. Da das benutzte CPR-Modell Ambu-Man©, ebenso wie andere Modelle, nicht für eine Kompression von dorsal und mittels "load-distributing band" eines AutoPulse™ konstruiert ist, weist es andere Werte in der Thorax-Compliance etc. auf, die die nichtleitlinienkonforme Drucktiefe und den leichten Unterschied der Drucktiefe zwischen Rückenlage und Bauchlage in unserer Studie ebenfalls begründet. Aufgrund der anatomisch-physiologischen Gegebenheiten der relativ star- Anaesthesist https://doi.org/10.1007/s00101-020-00851-1 © Springer Medizin Verlag GmbH, ein Teil von Springer Nature 2020 Automatic load-distributing band CPR (AutoPulse™) in prone position, feasible? Abstract Background. Due to SARS-CoV-2 respiratory failure, prone positioning of patients with respiratory and hemodynamic instability has become a frequent intervention in intensive care units (ICUs), and even in patients undergoing transfer in an ambulance or helicopter. It has become increasingly important how to perform safe and effective CPR in prone position, achieving both an optimal outcome for the patient and optimal protection of staff from infection. Materials and Methods. We conducted feasibility tests to assess the effects of CPR with an automatic load-distributing band (AutoPulse™) in prone position and discussed different aspects of mechanical chest compression (mCPR) in prone position. Results. In supine position, AutoPulse™ generated a constant pressure depth of 3cm at a frequency of 84/min. In prone position, AutoPulse™ generated a constant pressure depth of 2.6cm at a frequency of 84/min. Conclusion. We found mCPR to be feasible in manikins in both prone and supine positions. Mechanical chest compression devices · Cardiopulmonary resuscitation · Loaddistributing band CPR device · CPR in prone positioning · SARS-CoV-2 ren Wirbelsäule erscheinen mechanische Kompressionssysteme aus der Gruppe der "Stempelsysteme" für diesen Einsatz als potenziell ungünstiger im Vergleich zu Geräten wie dem AutoPulse™, die mittels eines "load-distributing band" arbeiten. Ungeachtet dieser Einschränkungen konnte in diesem Versuchsaufbau gezeigt werden, dass eine Thoraxkompression in Bauchlage mittels AutoPulse™ im CPR-Modell machbar ist. Aufbauend auf die-sen Erkenntnissen, die als Denkanstoß für weitere Untersuchungen dienen können, müssen einerseits die Reproduzierbarkeit der Anwendung und die klinische Effektivität wie z. B. adäquate zerebrale Perfusion in weiterführenden Studien bestätigt werden. Interim guidance for basic and advanced life support in adults, children, and neonates with suspected or confirmed COVID-19: from the Emergency Cardiovascular Care Committee and Get With The Guidelines-Resuscitation Adult and Pediatric Task Forces of the Mechanical chest compression devices in the helicopter emergency medical service in Switzerland A need for prone position CPR guidance for intubated and nonintubated patients during the COVID-19 pandemic Reverse CPR: a pilot study of CPR in the prone position Funktionalität und Einsatztauglichkeit von Thoraxkompressionsgeräten