key: cord-0692848-1vo72gop authors: Zhang, Dan; Lou, Xiuyu; Yan, Hao; Pan, Junhang; Mao, Haiyan; Tang, Hongfeng; Shu, Yan; Zhao, Yun; Liu, Lei; Li, Junping; Chen, Jiang; Zhang, Yanjun; Ma, Xuejun title: Metagenomic analysis of viral nucleic acid extraction methods in respiratory clinical samples date: 2018-10-25 journal: BMC Genomics DOI: 10.1186/s12864-018-5152-5 sha: 9fd83230962e678e8ec4d5dffee0bb431e19c2d9 doc_id: 692848 cord_uid: 1vo72gop BACKGROUND: Numerous protocols for viral enrichment and genome amplification have been created. However, the direct identification of viral genomes from clinical specimens using next-generation sequencing (NGS) still has its challenges. As a selected viral nucleic acid extraction method may determine the sensitivity and reliability of NGS, it is still valuable to evaluate the extraction efficiency of different extraction kits using clinical specimens directly. RESULTS: In this study, we performed qRT-PCR and viral metagenomic analysis of the extraction efficiency of four commonly used Qiagen extraction kits: QIAamp Viral RNA Mini Kit (VRMK), QIAamp MinElute Virus Spin Kit (MVSK), RNeasy Mini Kit (RMK), and RNeasy Plus Micro Kit (RPMK), using a mixed respiratory clinical sample without any pre-treatment. This sample contained an adenovirus (ADV), influenza virus A (Flu A), human parainfluenza virus 3 (PIV3), human coronavirus OC43 (OC43), and human metapneumovirus (HMPV). The quantity and quality of the viral extracts were significantly different among these kits. The highest threshold cycle(Ct)values for ADV and OC43 were obtained by using the RPMK. The MVSK had the lowest Ct values for ADV and PIV3. The RMK revealed the lowest detectability for HMPV and PIV3. The most effective rate of NGS data at 67.47% was observed with the RPMK. The other three kits ranged between 12.1–26.79% effectiveness rates for the NGS data. Most importantly, compared to the other three kits the highest proportion of non-host reads was obtained by the RPMK. The MVSK performed best with the lowest Ct value of 20.5 in the extraction of ADV, while the RMK revealed the best extraction efficiency by NGS analysis. CONCLUSIONS: The evaluation of viral nucleic acid extraction efficiency is different between NGS and qRT-PCR analysis. The RPMK was most applicable for the metagenomic analysis of viral RNA and enabled more sensitive identification of the RNA virus genome in respiratory clinical samples. In addition, viral RNA extraction kits were also applicable for metagenomic analysis of the DNA virus. Our results highlighted the importance of nucleic acid extraction kit selection, which has a major impact on the yield and number of viral reads by NGS analysis. Therefore, the choice of extraction method for a given viral pathogen needs to be carefully considered. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12864-018-5152-5) contains supplementary material, which is available to authorized users. Next-generation sequencing (NGS) is an attractive approach to diagnosis of infection and might serve as a great potential method to identify viruses, bacteria, and fungi from a range of biological and environmental samples in clinical diagnostic and reference labs [1, 2] . Various NGS approaches provide solutions for detection of purified and concentrated viruses from culture, however, direct identification of viral genomes from clinical specimens using NGS methods still has its challenges, including noise from the host or microbiota cells and the limited viral RNA and DNA quantities [3, 4] . Numerous protocols for viral enrichment and genome amplification have been described in literature [5] [6] [7] . Commonly employed protocols such as sample filtration [8] , nuclease digestion, ultracentrifugation, and random pre-amplification of RNA or DNA in separate reactions would be particularly useful for increasing the signal-to-noise ratio in the viral analysis of biological samples in which the levels of nucleic acid background are high. In principle, these protocols can significantly reduce the proportion of human and bacteria reads and increase the number of viral reads. In fact, filtration and nuclease treatment slightly decreased the number of virus reads and the number of viruses identified [6] . Pre-amplification using random RT-PCR resulted in detection of fewer viruses, more overlapping sequences, but lower genome coverage [6] . Amplicon-based NGS only detected pre-defined targets, thus possibly missing viruses or novel virus strains. Apart from these methods, a crucial step in the molecular detection of viruses in clinical specimens is the efficient extraction of viral nucleic acids [7] . Higher virus-related yields of the extracts meant better sensitivity in the subsequent detection analysis. Thus the extraction method selected may determine the sensitivity and reliability of diagnostic NGS [9] . As sample types greatly influence the composition of a sequencing read due to the complexity of clinical materials, it is therefore valuable to use the nucleic acid extracted directly from clinical specimens without enrichment to evaluate extraction efficiency. In this study, we assessed the viral nucleic acid extraction efficiency of four commonly used Qiagen kits: QIAamp Viral RNA Mini Kit (VRMK), QIAamp MinElute Virus Spin Kit (MVSK), RNeasy Mini Kit (RMK), and RNeasy Plus Micro Kit (RPMK). Among them, the VRMK [10] [11] [12] [13] , MVSK [14] [15] [16] and RMK [3, 17, 18] were described in the literature on NGS-based detection using respiratory specimens. The performance of these kits for viral nucleic acid extraction was compared with regard to simultaneous isolation of viral DNA and RNA by qRT-PCR analysis. The number of reads containing five different viruses, distribution of viral sequencing reads into taxonomic categories, and the percentage of virus-specific reads generated by sequencing on the Illumina Hiseq 2500 system were evaluated in parallel using identical NGS processes and bioinformatics analyses. The mixed samples were from two nasopharyngeal aspirate specimens, which contained an adenovirus (ADV), influenza virus A (Flu A), human parainfluenza virus 3 (PIV3), human coronavirus OC43 (OC43), and human metapneumovirus (HMPV) without any pre-treatment approaches. These viruses were chosen to cover a wide range of different viral properties: non-enveloped DNA virus (ADV), enveloped single-stranded, segmented RNA virus (Flu A), enveloped negative-stranded RNA virus (PIV3, HMPV), and enveloped positive-stranded RNA virus (OC43). For a fair comparison of four commercially available viral nucleic acid extraction kits, the same amounts of starting sample and elution buffer were used and five different viruses with different characteristics were chosen: Flu A, OC43, HPIV3, HMPV, and ADV. Following the nucleic acid extraction, virus elutes were initially quantified by qRT-PCR to determine the performance of each kit. Later, for each kit, two parallel libraries from two extracted aliquots of the same sample were individually generated using the same sequencing protocols and bioinformatics analyses. The parallel results showed good repeatability for each kit (see Additional file 1). According to the qRT-PCR results (Table 1) , the highest Ct values for ADV and OC43 were obtained by using the RPMK. For Flu A, PIV3, ADV, HMPV, and OC43, the lower Ct values were achieved with the VRMK, while the MVSK had the lowest Ct values for ADV and PIV3. The RMK revealed the lowest detectability for HMPV and PIV3. All five viruses showed detectable amounts of the viral nucleic acid in the respective samples, except for Flu A, which was undetected with the RPMK. The nucleic acid concentrations of the DNA preparation were close to 1 ng/μL, which is the amount theoretically required for the use of the Next® Ultra™ DNA library Prep Kit, according to the manufacturer's recommendations ( Table 2 ). The highest DNA concentration on average was found in samples extracted by the MVSK (95.2 ng/μL), while extraction with the RPMK resulted in the lowest average concentration (0.10 ng/μL). Moderate DNA concentrations were observed with the VRMK (7.12 ng/μL) and RMK (2.47 ng/μL). The best result is presented in bold The Illumina sequencing of the respective libraries (n = 8) generated a total of 140 million paired-end reads, with a total of 21.08 Gbp of sequence information. On average, the percentage of bases with a quality score greater than 30 was 93.84% ( Table 3 ). The amount of NGS data exhibited no particularly large differences among the eight samples. Reads passing quality filtering were mapped to the human reference genome hg18 using stringent criteria. The most effective rate of NGS data of 67.47% was observed with the RPMK ( Table 3 ). The other three kits' effectiveness rates of NGS data ranged between 12.1-26.79%. Most importantly, the highest proportion of non-host reads was obtained by the RPMK compared to the other three kits (Fig. 1) . As shown in Table 4 , extraction efficiencies of the four kits for five viruses were different. When aligned with the PIV3 reference genome sequence (GenBank accession number NC_001796.2), the RPMK generated sequences with up to a 100% breadth of coverage (94.5% nucleotide pairwise identity), with the highest PIV3 read number (58,338,663 reads), and the highest coverage for OC43 (0.83%) and HMPV (33.95%). The PIV3 full genome sequences were deposited into the GenBank under accession number MH411617. Compared to the RMK, the PIV3 genome reads were increased 5851-fold. In contrast, the lowest reads and coverage of ADV and Flu A were obtained by using the RPMK. The RMK produced the highest coverage percentage (79.32%) for the ADV. There were no considerable differences among the four kits in the read number and coverage for the Flu A (read 1-16, coverage 1.20-2.81). The proportions of sequence reads with significant hits for viruses, bacteria, unknown, other, and human entries are summarized in Fig. 1 . We observed improvements in the rate of virus and bacteria detection in the clinical samples with the RPMK extraction. An average of 9.61, 44.67 and 33.02% reads were classified as known viruses, bacteria, and human, respectively. In contrast, only about 0.01-0.05% (average, 0.03%) of the valid sequences were classified as viruses with the other three kits. Limiting factors in the nucleic acid extraction are lower pathogen concentration and specimen volume that could result in insufficient amounts of NGS starting material. Therefore, increasing sample volume is an effective solution for viral metagenomics analysis in order to improve the number of virus reads and genome coverage. In addition, increased sequencing capacity also improves the chances of virus detection [19] . Although the use of more massive throughput NGS platforms may increase the cost of use, it is still a reliable and effective method [20] . In this study, we compared the extraction efficiency of four commonly used Qiagen extraction kits (VRMK, MVSK, RPMK, and RMK) using the same amount of input and output (elute) of the same sample. In contrast to using cell-cultured reference viruses, this study focused on NGS-based detection and analysis of respiratory clinical specimens. We evaluated the performance of aforementioned four kits with NGS in terms of the ability of each kit to recover sequence information of five different DNA and RNA viruses in the clinical samples. To ensure the reliability and repeatability of experimental results, we set up the extraction (n = 8, 2 for each kit), qRT-PCR assay (n = 16, 2 for each extraction), and NGS analysis (n = 8, 2 for each kit) in duplicate. With the RPMK procedure, samples are first lysed and homogenized in a highly denaturing guanidine-isothiocyanate-containing buffer, which immediately inactivates RNases to ensure isolation of intact RNA. The lysate is then passed through a gDNA eliminator spin column. This column, in combination with the optimized high-salt buffer, efficiently removes Table 3 ) in removing human reads, the RPMK effectively reduced the amount of human reads, dramatically increased the proportion of viral RNA (9.61%) and bacterial reads (44.67%) (Fig. 1) , and even obtained the full PIV3 genome sequence, thus providing sufficient sequence information to confirm virus identity. With whole viral genome sequences, it can also inform likely phenotypes, including drug susceptibility or neutralization serotypes and may prove useful in viral transmission and evolution studies [21, 22] . To our best knowledge, this is the first study on viral metagenomics analysis of respiratory clinical samples without pre-treatment approach using the RPMK. Interestingly, the ratio of viral reads and coverage obtained by the NGS was not well correlated with Ct values of the same sample, highlighting the importance and necessity of using different methods to evaluate extraction efficiency. The qRT-PCR results demonstrated With qRT-PCR analysis only, our data also showed that different kits may exhibit different extraction efficiency for the same and different viruses. Dramatic differences in the Ct values were observed among the five selected viruses (Table 1) . Before pooling, the original Ct values for the ADV, Flu A, PIV3, OC43, and HMPV were 23.9, 26.5, 17.1, 29.2, and 27.1, respectively, which were lower than the results obtained using tested kits in this study. This may be explained by the use of automated extraction platform and the addition of carrier RNA in the original extraction methods, a typical way to increase the extract yield. The repeated freeze-thawing steps might also contribute to this bias. As appropriate kit choice can be a crucial factor in determination of experiment results, our results implied that no suitable kit is perfect for all the viral pathogens and the choice of extraction method for a given viral pathogen needs to be carefully considered. Notably, viral RNA extraction kits are able to isolate viral DNA effectively. The VRMK, RPMK, and RMK are designed for viral RNA extraction, while the MVSK for both viral DNA and RNA extraction, according to manufacturer's recommendations. Compared to the other thee kits, it is not surprising that with qRT-PCR analysis, the MVSK performed best with the lowest Ct value of 20.5 in the extraction of the ADV (DNA virus), while the VRMK, RPMK, and RMK achieved moderate and higher Ct values of 24.2, 34.5, and 26.9, respectively. Further NGS analysis results placed the extraction kits in the order of decreasing extraction efficiency as follows: RMK, VRMK, MVSK, and RPMK, indicating that the RMK is actually most suitable for the ADV identification, rather than the MVSK. We assumed that viral RNA extraction kits were also applicable for metagenomic analysis of the DNA virus, probably by effectively capturing the RNA transcripts of the DNA virus in the extracted clinical sample. Our results provide contrasting evidence to a previous study [9] , which reported the evaluation of four different commercial nucleic acid extraction kits with four different viruses and concluded that selection of kits has only a minor impact on the yield of viral reads and the read numbers obtained by NGS. The following factors might explain the differences between our study and previously reported research: 1) different extraction kits and tested viruses were used; 2) mixed aliquots from egg-or cell-cultured reference viruses were used in previous work, while mixed clinical samples were used in the current study; 3) each extracted nucleic acid in an earlier study was divided into two aliquots, with one of the aliquots being subjected to DNA and the other to RNA processing for NGS, while in the current work each extracted nucleic acid was further treated by each procedure in duplicate. The evaluation of viral nucleic acid extraction efficiency is different between the NGS and qRT-PCR analysis. The RPMK was most applicable for metagenomic analysis of viral RNA and enabled more sensitive identification of the RNA virus genome in respiratory clinical samples. Viral RNA extraction kits were also applicable for metagenomic analysis of the DNA virus. The results obtained in this study may differ if the NGS workflow and sequencing are not performed with the NEB Next® Ultra™ DNA library Prep Kit and Illumina Hiseq 2500 system. Further study will explore the influence of different extraction methods on the metagenomic analysis of viral nucleic acid using diverse biological samples including human feces, blood, and tissues containing multiple viral agents. The evaluation of viral nucleic acid extraction efficiency is different between NGS and qRT-PCR analysis. The RPMK was most applicable for the metagenomic analysis of viral RNA and enabled more sensitive identification of the RNA virus genome in respiratory clinical samples. In addition, viral RNA extraction kits were also applicable for metagenomic analysis of the DNA virus. Our results highlighted the importance of nucleic acid extraction kit selection, which has a major impact on the yield and number of viral reads by NGS analysis. Therefore, the choice of extraction method for a given viral pathogen needs to be carefully considered. A spiked mixture was from two nasopharyngeal aspirate specimens, which contained ADV, Flu A, HPIV3, OC43, and HMPV. Before pooling, we used the cador Pathogen 96 QIAcube HT Kit (Qiagen) for automated viral DNA and RNA extraction with the QIAcube HT System. The presence of each virus was tested by individual qRT-PCR using specific primers and probes targeting different genomes [23] . The Ct values for the ADV, Flu A, PIV3, OC43, and HMPV were 23.9, 26.5, 17.1, 29.2, and 27.1, respectively. The Ct values are inverse to the nucleic acid concentration in correlation with the number of copies in the sample. Therefore, the lower the Ct values, the more abundant the nucleic acid presence. A 200-μL aliquot of the mixture was subjected to subsequent extraction in duplicate (n = 2) using four commercially available kits. Four commercially available kits (VRMK, MVSK, RPMK, and RMK) were compared using simultaneous isolation of viral DNA and RNA, even though some kits were primarily designed exclusively for DNA or RNA ( Table 5 ). The selection of the individual kits was based on their commercial availability and literature reports. The RPMK is used for purification of total RNA with the gDNA eliminator columns from small samples, including animal and human cells, tissues and microdissected cryosections, and for RNA cleanup and concentration. Major differences among the utilized commercial kits are their different chaotropic salts, detergents, and other additives included in the lysis buffers. The mixed sample was homogenized by vortexing. Nucleic acid was extracted in parallel from 200 μL of the aliquot in duplicate for each kit, according to each of the manufacturer's instructions (processed in the absence of viral enrichment). No carrier RNA was used for the extraction. Finally, the extracted nucleic acid was eluted individually (n = 8) in the same volume of 50 μL of the AVE buffer or RNase-free water. Following nucleic acid extraction by the four kits (Table 5) , their individual performance with regard to the yield of viral nucleic acids was compared using qRT-PCR [23] . Specific qRT-PCR protocols were individually performed in duplicate (n = 16) for each virus and each extract (n = 8), using the 7500 Real Time PCR System (Applied Biosystems) for quantification of the ADV, OC43, Flu A, HMPV, and PIV3. The PCR mixtures consisted of 7.5 μL of the qRT-PCR buffer mix, 7.5 μL of each primer/probe set, and 5 μL of the 5 × enzyme mix (AgPath-ID™ One-Step RT-PCR Kit, Applied Biosystems). All qRT-PCR experiments were performed in a final 25-μL reaction volume containing 5 μL of the nucleic acid elute with the following cycling conditions: 30 min at 50°C, 5 min at 95°C, 40 cycles of 10 s at 95°C , and 45 s at 55°C. Prior to further library processing, the yield of total extracted nucleic acid was quantified using the Qubit assay kit on the Qubit® 2.0 Flurometer. The Qubit® dsDNA HS Assay Kit (Invitrogen) is highly selective for double-stranded DNA and is designed to be accurate for the initial sample concentrations between 10 pg/μL and 100 ng/μL. The Qubit® RNA HS Assay Kit (Invitrogen) is designed to be accurate for RNA sample concentrations between 250 pg/μL and 100 ng/μL. Each viral extract (n = 8) was subjected to reverse transcription and PCR amplification. Eleven microliters of the elute were used as a template in a total volume of 20 μL, with 1 μL of random primer (50 μM), 1 μL of dNTPs (10 mM), 4 μL of 5 × first strand buffer, 1 μL of DTT (0.1 M), and 1 μL (200 units/μL) of SuperScript III (Invitrogen). The template and random primers were heated for 5 min at 65°C, followed by reverse transcription for 60 min at 42°C, and inactivation for 5 min at 96°C. Prior to the second strand synthesis, cDNA was denatured for 2 min at 94°C and cooled down for 5 min at 10°C. The second strand was synthesized with 5 U/ μL Klenow fragment exo-polymerase (Thermo Fisher Scientific) in a final volume of 10 μL and incubated at 37°C for 30 min, followed by an enzyme inactivation Sequencing libraries were prepared with individual indices using the NEB Next® Ultra™ DNA library Prep Kit for Illumina (NEB, USA), following manufacturer's recommendations. Index codes were added to attribute sequences to each sample. Briefly, the DNA sample was fragmented by sonication to a size of 300 bp, then DNA fragments were end-polished, A-tailed, and ligated with the full-length adaptor for the Illumina sequencing with further PCR amplification (8 cycles). Finally, the PCR products were purified (AMPure XP system) and libraries were analyzed for size distribution by the Agilent 2100 Bioanalyzer and quantified using RT-PCR. Sequencing was performed on the Illumina HiSeq 2500 system with the output of 2 × 150 bp paired-end reads. The clustering of the index-coded samples was performed on a cBot Cluster Generation System, according to the manufacturer's instructions. After cluster generation, the library preparations were sequenced on the Illumina HiSeq2500 platform and paired-end reads were generated. The workflow was used to compare the performance of four different commercially available extraction kits on the selected viruses. The NGS runs (n = 8, corresponding to eight extractions) were performed in parallel. The raw reads were filtered to remove low quality sequences and adapted with Trimmomatic (Version 0.36) and ng_QC (Version 1.0). After quality control was performed, the reads were further compared to the human reference genome hg19 and the aligned host reads were detected using the SoapAligner (Version 2.21). To assess the taxonomic assignment, the resulting reads for each sample were aligned with the virus database (July, 2015) and viral protein database from the NCBI Refseq database (July, 2015) using the VIP analysis software (Version 0.1.1) [24] . The sequences of five selected viruses (NCBI taxid 10,535, 162,387, 12,730, 11,216, 31,631, and 11,308) were extracted from the NCBI Refseq (August, 2017) and NCBI-NT (August, 2017) databases. In order to detect the selected viruses, all clean reads of each sample were mapped to the sub-Refseq (118 genomes) and sub-NT databases (396,146 sequences) with the SoapAligner (Version 2.21). Finally, for each sample, the reads that were mapped to the same species of the sub-NT database were assembled to contigs by the MEGAHIT (Version 1.1.1) . The contigs were then mapped to the sub-NT database to determine the taxonomic classification. Additional file 1: Figure S1 . UPGMA (Unweighted Pair-group Method with Arithmetic Mean) analysis of the eight samples tested. Tree representing the results of the UPGMA hierarchical clustering of the weighted UniFrac distance matrix for each extraction in duplicates (n = 2) using four commercially available kits. The scale bar indicates the distance between clusters in UniFrac units. Four different extraction kits showed differences in grouping of eight extractions in Figure S1 . The similarities and differences between the species and phylum communities in the four extraction kits were further quantified through UPGMA clustering analysis based on the weighted UniFrac distance metric. The results were clustered for each extraction kit and the parallel results within each extraction kit showed good repeatability. (DOCX 65 kb) Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. Author details Viral metagenomics Metagenomics and future perspectives in virus discovery Unbiased parallel detection of viral pathogens in clinical samples by use of a metagenomic approach Identification of a novel human papillomavirus by metagenomic analysis of samples from patients with febrile respiratory illness Optimization and validation of sample preparation for metagenomic sequencing of viruses in clinical samples Comparing viral metagenomics methods using a highly multiplexed human viral pathogens reagent Evaluation of methods for the concentration and extraction of viruses from sewage in the context of metagenomic sequencing Comprehensive virome analysis reveals the complexity and diversity of the viral spectrum in pediatric patients diagnosed with severe and mild hand-foot-and-mouth disease Comparing viral metagenomic extraction methods Metagenomics study of viral pathogens in undiagnosed respiratory specimens and identification of human enteroviruses at a Thailand hospital A metagenomics study for the identification of respiratory viruses in mixed clinical specimens: an application of the iterative mapping approach Viral pathogen detection by metagenomics and Pan-viral group polymerase chain reaction in children with pneumonia lacking identifiable etiology Discovery of a divergent HPIV4 from respiratory secretions using second and third generation metagenomic sequencing Characterization of the nasopharyngeal viral microbiome from children with community-acquired pneumonia but negative for Luminex xTAG respiratory viral panel assay detection Unbiased detection of respiratory viruses by use of RNA sequencing-based metagenomics: a systematic comparison to a commercial PCR panel Metagenomic analysis of viral genetic diversity in respiratory samples from children with severe acute respiratory infection in China Simultaneous virus identification and characterization of severe unexplained pneumonia cases using a metagenomics sequencing technique First report of human salivirus/klassevirus in respiratory specimens of a child with fatal adenovirus infection Evaluation of high-throughput sequencing for identifying known and unknown viruses in biological samples Evaluation of convenient pretreatment protocols for RNA virus metagenomics in serum and tissue samples Emergence and evolution of novel Reassortant influenza a viruses in canines in southern China Full-genome sequencing of porcine circovirus 3 field strains from Denmark, Italy and Spain demonstrates a high within-Europe genetic heterogeneity Clinical evaluation of a panel of multiplex quantitative real-time reverse transcription polymerase chain reaction assays for the detection of 16 respiratory viruses associated with community-acquired pneumonia VIP: an integrated pipeline for metagenomics of virus identification and discovery We acknowledge the Children's Hospital, Zhejiang University School of Medicine and the Center for Disease Control and Prevention of Zhejiang province for providing nasopharyngeal aspirate specimens. All of the datasets supporting the results of this article are included within the article and its Additional files. The raw data generated in this study can be obtained by reasonable request to the corresponding authors.Authors' contributions DZ and XYL contributed equally and therefore are co-first authors. YJZ and XJM conceived and designed the study. JHP and HYM provided cDNA libraries and generated Illumina libraries YZ, LL and JPL obtained clinical samples and participated in patient care. HY and JC performed statistical analysis. HFT and YS supervised the confirmatory five respiratory viruses RT-PCR. DZ and XYL wrote the manuscript. All authors read and approved the final manuscript. Human clinical samples were collected from two patients who were admitted to the Children's Hospital of Zhejiang, China with community-acquired pneumonia. Written informed consent was obtained from parents or caregivers before enrollment, with children providing assent when age-appropriate. The study protocol was approved by the Institutional Review Boards of the Center for Disease Control and Prevention of Zhejiang. Not applicable. The authors declare that they have no competing interests.