key: cord-0692596-n0gv4op6 authors: Zhang, Jianqiang; Tsai, Yun-Long; Lee, Pei-Yu Alison; Chen, Qi; Zhang, Yan; Chiang, Cheng-Jen; Shen, Yu-Han; Li, Fu-Chun; Chang, Hsiao-Fen Grace; Gauger, Phillip C.; Harmon, Karen M.; Wang, Hwa-Tang Thomas title: Evaluation of two singleplex reverse transcription-Insulated isothermal PCR tests and a duplex real-time RT-PCR test for the detection of porcine epidemic diarrhea virus and porcine deltacoronavirus date: 2016-04-06 journal: J Virol Methods DOI: 10.1016/j.jviromet.2016.03.016 sha: c58715798b7ae050186df99882c4f62fd73c2916 doc_id: 692596 cord_uid: n0gv4op6 Recent outbreaks of porcine epidemic diarrhea virus (PEDV) and porcine deltacoronavirus (PDCoV) in multiple countries have caused significant economic losses and remain a serious challenge to the swine industry. Rapid diagnosis is critical for the implementation of efficient control strategies before and during PEDV and PDCoV outbreaks. Insulated isothermal PCR (iiPCR) on the portable POCKIT™ device is user friendly for on-site pathogen detection. In the present study, a singleplex PEDV RT-iiPCR, a singleplex PDCoV RT-iiPCR, and a duplex PEDV/PDCoV real-time RT-PCR (rRT-PCR) commercial reagents targeting the M gene were compared to an N gene-based PEDV rRT-PCR and an M gene-based PDCoV rRT-PCR that were previously published and used as reference PCRs. All PCR assays were highly specific and did not cross react with other porcine enteric pathogens. Analytical sensitivities of the PEDV RT-iiPCR, PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR were determined using in vitro transcribed RNA as well as viral RNA extracted from ten-fold serial dilutions of PEDV and PDCoV cell culture isolates. Performance of each PCR assay was further evaluated using 170 clinical samples (86 fecal swabs, 24 feces, 19 intestines, and 41 oral fluids). Compared to the reference PEDV rRT-PCR, the sensitivity, specificity and accuracy of the PEDV RT-iiPCR were 97.73%, 98.78%, and 98.24%, respectively, and those of the duplex PEDV/PDCoV rRT-PCR were 98.86%, 96.34%, and 97.65%, respectively. Compared to the reference PDCoV rRT-PCR, the sensitivity, specificity and accuracy of the PDCoV RT-iiPCR were 100%, 100%, and 100%, respectively, and those of the PEDV/PDCoV duplex rRT-PCR were 96.34%, 100%, and 98.24%, respectively. Overall, all three new PCR assays were comparable to the reference rRT-PCRs for detection of PEDV and/or PDCoV. The PEDV and PDCoV RT-iiPCRs are potentially useful tools for on-site detection and the duplex PEDV/PDCoV rRT-PCR provides a convenient method to simultaneously detect the two viruses and differentiate PEDV from PDCoV. Coronaviruses (CoVs) are enveloped, single-stranded, positivesense RNA viruses in the order Nidovirales and the family Coronaviridae. Four genera, Alphacoronavirus, Betacoronavirus, Gammacoronavirus, and Deltacoronavirus, have been described (Woo et al., 2010 (Woo et al., , 2012 . In pigs, five CoVs have so far been identified and these include: porcine epidemic diarrhea virus (PEDV), transmissible gastroenteritis virus (TGEV) and porcine respiratory coronavirus (PRCV) in the Alphacoronavirus genus; porcine hemagglutinating encephalomyelitis virus (PHEV) in the Betacoronavirus genus; and porcine deltacoronavirus (PDCoV) in the Deltacoronavirus genus. PEDV, TGEV and PDCoV primarily cause enteric infections in pigs; PRCV has a predilection for the respiratory tract; PHEV infection produces encephalomyelitis rather than enteritis. PEDV was first identified in England in the 1970s and has since spread to other European and Asian countries (Song and Park, 2012) . In October 2010, the PEDV strains circulating in China were reported to have become more virulent than classical PEDV strains, with some causing up to 100% morbidity and high mortality in suckling piglets (Li et al., 2012; Sun et al., 2012) . In April 2013, PEDV emerged in United States (U.S.) swine and caused severe illness and high mortality in piglets (Stevenson et al., 2013) . Sequence analyses revealed that the U.S. virulent PEDVs (U.S. PEDV prototype strain) are most genetically similar to the Chinese virulent PEDV strain AH2012 Huang et al., 2013; Stevenson et al., 2013) . In January 2014, a mildly virulent PEDV variant was identified in the U.S. that had insertions and deletions in the spike gene (U.S. S-INDEL-variant strain) compared to the virulent U.S. PEDV prototype strain (Chen et al., 2016a; Vlasova et al., 2014; Wang et al., 2014b) . Since its emergence in the U.S. in April 2013, PEDV has spread rapidly across the country and resulted in the estimated death of 8 million pigs in the first year, causing economic losses of $900 million to $1.8 billion (Paarlberg, 2014) . In addition, PEDV has recently also emerged or re-emerged in China, Japan, South Korea, Philippines, Thailand, Vietnam, Canada, Mexico, Germany, Belgium, France and Portugal (Grasland et al., 2015; Mesquita et al., 2015; Pasick et al., 2014; Puranaveja et al., 2009; Song and Park, 2012; Stadler et al., 2015; Theuns et al., 2015; Vlasova et al., 2014; Vui et al., 2015) . Currently, PEDV remains a significant threat to the global swine industry. Porcine deltacoronavirus was first detected in pig samples collected in 2009 by a Hong Kong group (Woo et al., 2012) . In the U.S., PDCoV was first reported in early 2014 Marthaler et al., 2014; Wang et al., 2014a) but PCR-based retrospective testing indicated that PDCoV was present in U.S. swine at least from August 2013 . Pathogenicity of PDCoV has been experimentally confirmed in pigs Jung et al., 2015; Ma et al., 2015) . Recently PDCoV has also been reported in South Korea and China Song et al., 2015) . Infection with PEDV, PDCoV and TGEV can lead to similar clinical symptoms including diarrhea, dehydration, variable vomiting, and high mortality especially in neonatal piglets. These clinical diseases and lesions are indistinguishable and specific laboratory diagnostic testing is imperative to differentiate PEDV, PDCoV and TGEV infection. However, prevalence of TGEV in the swine population has been very low in recent years based on data from various veterinary diagnostic laboratories (unpublished) while detection and differentiation of emerging PEDV and PDCoV have become critical. Polymerase chain reaction (PCR) is a rapid, sensitive and specific tool and is currently most commonly used for detecting PEDV and PDCoV from clinical samples. A number of real-time reverse transcription PCR (rRT-PCR) assays have been developed for the detection of PEDV (Alonso et al., 2014; Jung et al., 2014; Kim et al., 2007; Lowe et al., 2014; Opriessnig et al., 2014; Thomas et al., 2015) and PDCoV Marthaler et al., 2014) . A spike genebased real-time RT-PCR has also been described to differentiate the U.S. prototype and S-INDEL-variant PEDV strains (Wang et al., 2014c) . However, implementation of these rRT-PCR assays requires trained technicians and sophisticated and expensive instruments and therefore these rRT-PCR assays are not suitable for on-site applications. In recent years, a point-of-need PCR detection platform integrating the insulated isothermal PCR (iiPCR) technology and a field-deployable device (POCKIT TM Nucleic Acid Analyzer) has been developed and is now commercially available for automatic detection and interpretation of PCR results within one hour (Tsai et al., , 2012b . The iiPCR or RT-iiPCR assays have been demonstrated to have excellent sensitivity and specificity for the detection of various targets, including classical swine fever virus in pigs (Lung et al., 2015) and various pathogens in shrimp, dogs, cats, and horses (Balasuriya et al., 2014; Tsai et al., 2012a Tsai et al., , 2014 Wilkes et al., 2015a Wilkes et al., ,b, 2014a . In the present study, commercial RT-iiPCR on POCKIT TM methods (POCKIT TM PEDV Reagent Set and POCKIT TM PDCoV Reagent Set, GeneReach USA, Lexington, MA, USA) available for on-site detection of PEDV and PDCoV, respectively, were evaluated. In addition, a commercial duplex rRT-PCR test (IQ REAL PEDV/PDCoV Quantitative System, GeneReach USA) available for simultaneous detection and differentiation of PEDV and PDCoV was evaluated as well. Analytical sensitivity, specificity, and clinical performance of the three newly established assays were compared with the previously published singleplex PEDV rRT-PCR (Lowe et al., 2014; Madson et al., 2014; Thomas et al., 2015) and singleplex PDCoV rRT-PCR assays . Isolation and characterization of the U.S. PEDV prototype isolate USA/IN19338/2013, U.S. PEDV S-INDEL-variant isolate USA/IL20697/2014, and U.S. PDCoV isolate USA/IL/2014 were previously described (Chen et al., , 2016b . For analytical sensitivity analysis, PEDV and PDCoV cell culture isolates were 10-fold serially diluted in minimum essential medium and subjected to RNA extraction and PCR testing. In order to determine the specificity of the PEDV and PDCoV RT-PCR assays, other porcine enteric pathogens were included in the study: TGEV Purdue strain (ATCC VR-763), TGEV Miller strain (ATCC VR-1740), PRCV ISU-1 strain, PHEV Mengling strain (NVSL 001-PDV), porcine rotaviruses (groups A-C), Escherichia coli, Salmonella typhimurium, Clostridium difficile, Clostridium perfringens, Brachyspira hyodysenteriae (B204), and Lawsonia intracellularis. A total of 170 clinical samples (86 fecal swabs, 24 feces, 19 small intestines and 41 oral fluids), submitted to the Iowa State University Veterinary Diagnostic Laboratory (ISU VDL) and tested for PEDV and PDCoV by virus-specific RT-PCRs, were selected to determine the performance of various PEDV and PDCoV PCRs evaluated in this study. Nucleic acids were extracted from virus isolates and their dilutions (50 l), bacterial isolates (50 l), small intestine homogenates (50 l), oral fluids (100 l), processed feces or fecal swabs (100 l) using a MagMAX TM Pathogen RNA/DNA Kit (Thermo Fisher Scientific, Waltham, MA, USA) and a Kingfisher-96 instrument (Thermo Fisher Scientific) following the instructions of the manufacturer. Nucleic acids were eluted into 90 l of Elution buffer. Nucleic acids were also extracted from clinical samples (fecal swab, feces, small intestine, and oral fluid) using taco TM mini Nucleic Acid Automatic Extraction System (taco TM mini, GeneReach USA). Briefly, 200 l of the samples were added into the first well of a taco TM Preloaded DNA/RNA Extraction plate (GeneReach USA) and subjected to the extraction steps as described in the manufacturer's user manual. Nucleic acids were eluted into 200 l of Elution buffer. To prepare the PEDV and PDCoV RNA standards, plasmids artificially synthesized to contain a fragment of the membrane (M) gene of PEDV USA/IN19338/2013 strain (nucleotides [nt] 25978-26066; GenBank accession no. KF650371) or a fragment of the M gene of PDCoV USA/IA/2014/8734 (nt 23356-23461; GenBank accession no. KJ567050) were linearized and subjected to in vitro transcription (IVT) using the MEGAscript T7 Kit (Thermo Fisher Scientific). RNA transcripts were produced, treated with DNase I, and purified by LiCl precipitation following the manufacturer's instructions. Copy numbers of RNA transcripts were calculated based on concentrations determined by a Nano-Drop 2000 spectrophotometer (Thermo Fisher Scientific). Serial dilutions of RNA were prepared in 40 ng/l yeast tRNA. Aliquots were frozen at −80 • C for single use of each aliquot. A singleplex PEDV nucleocapsid (N) gene-based rRT-PCR (Lowe et al., 2014; Madson et al., 2014; Thomas et al., 2015) and a singleplex PDCoV M gene-based rRT-PCR previously developed and routinely used at the ISU VDL for diagnostic testing were included in this study as the reference PCRs for the detection of PEDV and PDCoV. Each PCR was set up in a 20 l total reaction using TaqMan ® Fast 1-Step Master Mix (Thermo Fisher Scientific): 5 l of 4× Master Mix, 0.4 l of forward primer at 20 M, 0.4 l of reverse primer at 20 M, 0.24 l of probe at 10 M, 1 l XENO Internal Control Reagent (Thermo Fisher Scientific), 7.96 l nuclease-free water, and 5 l nucleic acid extract. Amplification reactions were performed on an ABI 7500 Fast instrument (Thermo Fisher Scientific) with the following conditions: 1 cycle of 50 • C for 5 min, 1 cycle of 95 • C for 20 s, and 40 cycles of 95 • C for 3 s and 60 • C for 30 s. Any cycle threshold (Ct) values <40 were reported as positive. The RT-iiPCR methods for PEDV (POCKIT TM PEDV Reagent Set, GeneReach, USA) and PDCoV (POCKIT TM PDCoV Reagent Set, GeneReach, USA) were designed according to the hydrolysis probebased POCKIT TM method described previously (Tsai et al., 2012b) . As shown in Table 1 , the primers and probe for PEDV were designed to target a highly conserved region in M gene among PEDV strains; the PDCoV RT-iiPCR primers and probe also targeted a highly conserved region in M gene among PDCoV strains. Both PEDV and PDCoV RT-iiPCR probes were labeled with FAM fluorescent reporter dye at the 5 end. The PEDV probe was labeled with an internal ZEN quencher and Iowa Black FQ (IWBkFQ) quencher at the 3 end. The PDCoV probe was labeled with a minor groove binder group (MGB) with a non-fluorescent quencher (NFQ) at the 3 end. After adding 5 l of the nucleic acid sample, the final Premix/sample mixture was transferred to an R-tube TM (GeneReach USA). The tube was spun briefly in a Cubee TM mini centrifuge (GeneReach USA) and placed into the reaction chamber of POCKIT TM Nucleic Acid Analyzer. The default program of the POCKIT TM device includes an RT step at 50 • C for 10 min and an iiPCR step at 95 • C for about 30 min. The reaction completed in less than one hour. POCKIT TM device collects optical signals through an integrated circuits controlledregulated sensor. Signal-to-noise (S/N) ratios were calculated by dividing light signals collected after iiPCR by those from before iiPCR (Tsai et al., 2012b) . Based on the default thresholds, S/N ratios of <1.2 and >1.3 were assigned as "+" and "−", respectively. A "?" result was assigned to those with an S/N ratio between 1.2 and 1.3, indicating that the signals were ambiguous and the sample should be tested again. Primers and probes of the duplex rRT-PCR for PEDV and PDCoV (IQ REAL PEDV/PDCoV Quantitative System, GeneReach USA) were designed to target two different highly conserved regions in the M gene among PEDV strains from all known clades and among all known PDCoV strains, respectively (Table 1 ). An internal control (IC) containing an artificial nucleotide sequence was also included in this multiplex rRT-PCR. The expected size of the IC amplicon was 100 bp. The PEDV, PDCoV, and IC amplicons were individually detected by a FAM-, NED-, and Cy5-labeled TaqMan probe, respectively. The rRT-PCR amplification was carried out in 25 l reaction mixtures containing 20 l of master mixture, 2.5 l of 200 nM ROX and 2.5 l of the extracted nucleic acids. The duplex PEDV/PDCoV rRT-PCR was performed on an ABI 7500 Fast instrument (Thermo Fisher Scientific). The conditions were set as follows: 30 min at 42 • C and 15 min at 93 • C, followed by 45 cycles of denaturation at 93 • C for 15 s and annealing-elongation at 60 • C for 1 min. Fluorescence signals were captured at the 60 • C step. The threshold for the Ct analysis was manually adjusted to 0.05, together with an automatic baseline. The Ct of the internal control was designed to be about 30 under these conditions. In addition to clinical samples, the serial dilutions of PEDV IVT RNA, PDCoV IVT RNA, PEDV isolates and PDCoV isolates were also tested by the duplex PEDV/PDCoV rRT-PCR. The linear correlation coefficient (R 2 ) and slope of the curve were determined automatically with the 7500 Real-Time PCR System software. The slope was used to calculate amplification efficiencies (E = 10 1/−slope − 1) for each primer/pair set. Based on statistical analysis of analytical sensitivity with IVT RNA of known copies, cutoff Ct of the duplex PEDV/PDCoV rRT-PCR for PEDV (FAM) and PDCoV (NED) detection was both set at 40 to achieve >50% detection at 10 copies per reaction (Caraguel et al., 2011) . For limit of detection 95% (LoD 95% ) calculation, probit regression analysis was performed to calculate the concentration of the template that could be measured with 95% probability using SPSS Statistics 14.0 (SPSS Inc., Chicago, IL). Kappa's tests were performed to determine the agreement between different RT-PCR assays and between different extraction methods. 3.1. Analytical specificity of PEDV RT-iiPCR, PDCoV RT-iiPCR, and duplex PEDV/PDCoV rRT-PCR assays As shown in Table 2 , the PEDV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR (reporter dye for PEDV detection) as well as the reference PEDV rRT-PCR only specifically reacted with PEDV and did not cross-react with other enteric pathogens including PDCoV, TGEV Purdue strain, TGEV Miller strain, PHEV, porcine rotaviruses (Groups A, B and C), PRCV, E coli, S. typhimurium, C. difficile, C. perfringens, B. hyodysenteriae, and L. intracellularis. Similarly, the PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR (reporter dye for PDCoV detection) as well as the reference PDCoV rRT-PCR only specifically reacted with PDCoV and did not cross-react with other enteric pathogens (Table 2) . The analytical sensitivities of the PEDV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR (FAM-labeled TaqMan probe) for PEDV detection were determined by testing 10-fold serial dilutions of an IVT RNA containing partial PEDV M gene sequence. For the PEDV RT-iiPCR, testing various replicates of 100, 50, 20, 5 and 0 copies of standard RNA per reaction revealed that 10/10 (100%), 20/20 (100%), 18/20 (90%), 9/20 (45%), and 0/24 (0%) produced positive results on these RNA copies, respectively. The LoD 95% of the PEDV RT-iiPCR was estimated to be 21 RNA copies/reaction by probit regression analysis. For the duplex PEDV/PDCoV rRT-PCR, each dilution of the PEDV IVT RNA (10 6 , 10 5 , 10 4 , 10 3 , 10 2 , 50, 20, 10, 5 and 0 copies) was run in two to eight replicates. The standard curve had an r 2 = 0.99 and a slope of −3.18 in the range of 10 6 to 10 copies of the PEDV IVT RNA. The LoD 95% of the duplex PEDV/PDCoV rRT-PCR for PEDV detection was calculated to be about 7 RNA copies/reaction by probit analysis. The analytical sensitivities of the PEDV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR assays for PEDV detection were also evaluated by testing RNA extracts from 10-fold serial dilutions (triplicate for each dilution) of PEDV cell culture isolates (U.S. PEDV prototype isolate and S-INDEL-variant isolate) and compared to that of an N gene-based singleplex PEDV rRT-PCR reference assay. The 100% detection endpoints of the PEDV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR to detect U.S PEDV prototype isolate and S-INDEL-variant isolate were both at 10 −5 dilutions (Table 3 ). In contrast, the 100% detection endpoints of the reference singleplex PEDV rRT-PCR were 10 −7 dilution for the U.S. PEDV prototype isolate and 10 −6 dilution for PEDV S-INDEL-variant isolate (Table 3 ), indicating that the PEDV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR were about 10-100 fold less sensitive than the reference singleplex PEDV rRT-PCR in detecting PEDV RNA. The analytical sensitivities of the PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR (NED-labeled TaqMan probe) for PDCoV detection were determined first by testing 10-fold serial dilutions of an IVT RNA containing the target PDCoV M gene sequence. The testing results of the PDCoV RT-iiPCR were 10/10 (100%), 24/24 (100%), 46/46 (100%), 13/16 (81%), 41/46 (89%) and 0/29 (0%) positive on reactions containing 100, 50, 20, 10, 5 and 0 PDCoV IVT RNA copies per reaction, respectively. The LoD 95% of the PDCoV RT-iiPCR was about 9 RNA copies/reaction by probit regression analysis. For the Table 2 Specificity of various PEDV and PDCoV RT-PCRs evaluated in this study. (For interpretation of the references to color in this table legend, the reader is referred to the web version of this article.) *Porcine rotaviruses include groups A-C porcine rotaviruses. l S/N: Signal-to-noise ratio. IC: Internal Control. Nucleic acids were extracted from all samples using the MagMAX TM Pathogen RNA/DNA Kit and Kingfisher-96 instrument from Thermo Fisher Scientific. Analytical sensitivity of PEDV RT-iiPCR and duplex PEDV/PDCoV real-time RT-PCR for detection of PEDV RNA and comparison with the reference singleplex PEDV real-time RT-PCR using viral RNA from the serially diluted PEDV cell culture isolates. (For interpretation of the references to color in this table legend, the reader is referred to the web version of this article.) Note: Nucleic acids were extracted from all samples using the MagMAX TM Pathogen RNA/DNA Kit and Kingfisher-96 instrument from Thermo Fisher Scientific. duplex PEDV/PDCoV rRT-PCR, each dilution of the PDCoV IVT RNA (10 6 , 10 5 , 10 4 , 10 3 , 10 2 , 50, 20, 10, 5 and 0 copies) was run in two to eight replicates. The standard curve had an r 2 = 0.99 and a slope of −3.13 in the range of 10 6 to 20 copies of the PDCoV IVT RNA. Accordingly, probit analysis indicated that LoD 95% of the duplex rRT-PCR for PDCoV was about 14 copies per reaction. Analytical sensitivities of the PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR were also determined by testing RNA extracts from 10-fold serial dilutions (triplicate for each dilution) of PDCoV cell culture isolate and compared to that of an M gene-based singleplex PDCoV rRT-PCR reference assay. The 100% endpoints to detect PDCoV were at 10 −5 dilution for both PDCoV RT-iiPCR and singleplex reference PDCoV rRT-PCR, and at 10 −4 dilution for the duplex PEDV/PDCoV rRT-PCR (Table 4 ), indicating that the duplex PEDV/PDCoV rRT-PCR was 10-fold less sensitive than the PDCoV RT-iiPCR and reference PDCoV rRT-PCR for PDCoV RNA detection. To evaluate the performances of the PEDV RT-iiPCR, PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR assays in detecting PEDV and PDCoV in clinical samples, previously published singleplex PEDV rRT-PCR and PDCoV rRT-PCR were used as the reference assays in a side-by-side comparison study testing a panel of 170 archived clinical specimens, including 86 fecal swabs, 24 feces, 19 intestines, and 41 oral fluid samples. Distributions of 170 clinical samples based on specimen types and Ct ranges are summarized in Table 5 . Among 170 samples, 88 samples were positive by the reference PEDV rRT-PCR with Ct ranges of 12.2-35.7; 82 samples were positive by the reference PDCoV rRT-PCR with Ct ranges of 15-37.1; 16 samples were positive for both PEDV and PDCoV. Comparisons of the PEDV RT-iiPCR and the reference PEDV rRT-PCR on testing 170 clinical samples for PEDV detection are summarized in Table 6a . Kappa analysis of the 2 × 2 contingency table showed that the sensitivity of the PEDV RT-iiPCR was 97.73% (CI 95%: 93.50-100%) and specificity was 98.78% (CI 95%: 94.86-100%) when compared to the reference PEDV rRT-PCR. Overall agreement between the reference PEDV rRT-PCR and the PEDV RT-iiPCR was 98.24% (CI 95%: 95.74-100%) with a kappa value of 0.96. As shown in Table 6b , when compared to the reference PEDV rRT-PCR, the sensitivity, specificity and accuracy of the duplex PEDV/PDCoV rRT-PCR for PEDV detection was 98.86% (CI 95%: 95.20-100%), 96.34% (CI 95%: 91.31-100%), and 97.65% (CI 95%: 94.92-100%; kappa = 0.95), respectively. As shown in Table 6c , 100% agreement (CI 95%: 98.90-100%; kappa = 1) was found between the PDCoV RT-iiPCR and the reference PDCoV rRT-PCR with the sensitivity of 100% (CI 95%: 96.80-100%) and specificity of 100% (CI 95%: 97.01-100%) for the Table 4 Analytical sensitivity of PDCoV RT-iiPCR and duplex PEDV/PDCoV real-time RT-PCR for detection of PDCoV RNA and comparison with the reference singleplex PDCoV real-time RT-PCR using viral RNA from the serially diluted PDCoV cell culture isolate. (For interpretation of the references to color in this table legend, the reader is referred to the web version of this article.) Note: Nucleic acids were extracted from all samples using the MagMAX TM Pathogen RNA/DNA Kit and Kingfisher-96 instrument from Thermo Fisher Scientific. PDCoV RT-iiPCR when compared to the reference PDCoV rRT-PCR. The sensitivity, specificity and accuracy of the duplex PEDV/PDCoV for PDCoV detection was 96.34% (CI 95%: 91.31-100%), 100% (CI 95%: 97.01-100%), and 98.24% (CI 95%: 95.74-100%; kappa = 0.96), respectively, when compared to the reference PDCoV rRT-PCR (Table 6d) . Discrepant results were observed on three samples between the PEDV RT-iiPCR and the reference PEDV rRT-PCR (Table 6a) , four samples between the duplex PEDV/PDCoV rRT-PCR and the reference PEDV rRT-PCR (Table 6b) , and three samples between the duplex PEDV/PDCoV rRT-PCR and the reference PDCoV rRT-PCR (Table 6d ). These discrepancies are summarized in Table 7 . 3.5. Performance comparisons between taco TM mini extraction/POCKIT TM PCR system and MagMAX TM extraction/real-time PCR system in detecting PEDV and PDCoV in clinical samples To evaluate the performance of the portable system combining the taco TM mini extraction and POCKIT TM amplification/detection method for PEDV and PDCoV detection in clinical samples, the taco TM mini extraction/PEDV RT-iiPCR system was compared to the MagMAX TM extraction/reference singleplex PEDV rRT-PCR system (Table 8a ) and the taco TM mini extraction/PDCoV RT-iiPCR system was compared to the MagMAX TM extraction/reference singleplex PDCoV rRT-PCR system (Table 8b) , based on testing 170 clinical samples. Five of the 88 positive samples identified by the MagMAX TM extraction/reference PEDV rRT-PCR system (#43Ct = 34.1; #45Ct = 32.6; #63Ct = 30.8; #75Ct = 35.1; and #146Ct = 35.7) were negative by the taco TM mini extraction/PEDV RT-iiPCR system (Table 8a ). All 82 samples negative by MagMAX TM extraction/reference PEDV rRT-PCR system were also negative by the taco TM mini extraction/PEDV RT-iiPCR system. Total agreement between the two systems was 97.06% (CI 95%: 94.12-100%; kappa = 0.94). When the 170 samples were tested for PDCoV, the MagMAX TM extraction/reference PDCoV rRT-PCR system and the taco TM mini extraction/PDCoV RT-iiPCR systems yielded the same results (Table 8b ) with 100% agreement (CI 95%: 98.43-100%; kappa = 1) between the two systems. Compared to the epidemic phase (April 2013-April 2014) of PEDV in the U.S., the incidence of PEDV has now subsided, but there are still 34 U.S. states positive for PEDV, 14 states positive for PDCoV, and 14 states with premises positive for both PEDV and PDCoV, according to the USDA report on October 22, 2015 (www. aasv.org). PEDV and PDCoV have also emerged or re-emerged in other countries. Rapid diagnosis is critical for the implementation of efficient control strategies before and during PEDV and PDCoV outbreaks. Table 6 Sensitivity and specificity of PEDV RT-iiPCR, PDCoV RT-iiPCR, and duplex PEDV/PDCoV rRT-PCR as compared to the reference singleplex PEDV rRT-PCR and PDCoV rRT-PCR based on testing 170 clinical samples. Recent technology of the iiPCR on the portable POCKIT TM device provides a simple, convenient and inexpensive method for on-site detection of pathogens in clinical samples (Tsai et al., 2012b) . For example, iiPCR methods have been used in small animal clinics and shelters (e.g. canine distemper virus and canine influenza virus), on livestock farms (e.g. porcine circovirus type 2), on shrimp farms (e.g. white spot syndrome virus and Enterocytozoon hepatopenaei), and by government agencies (e.g. classical swine fever virus and Vibrio parahaemolyticus-acute hepatopancreatic necrosis disease) for surveillance and diagnostic purposes in various countries (Lung et al., 2015; Tsai et al., 2014; Wilkes et al., 2014b ). In the current study, we developed and evaluated PEDV RT-iiPCR and PDCoV RT-iiPCR assays which were highly specific and did not cross react with other enteric pathogens. The PEDV RT-iiPCR and PDCoV RT-iiPCR had high analytical sensitivity with LoD 95% of 21 copies of PEDV RNA molecules per reaction and 9 copies of PDCoV RNA molecules per reaction, respectively. Analysis of viral RNA extracted from 10-fold serial dilutions of PEDV cell culture isolates (a U.S. PEDV prototype strain and a U.S. PEDV INDEL-variant strain) showed that the PEDV RT-iiPCR was 10-100 fold less sensitive for endpoint detection compared to the reference PEDV rRT-PCR (Lowe et al., 2014; Madson et al., 2014; Thomas et al., 2015) . However, it is noteworthy that the reference PEDV rRT-PCR was run 40 cycles in this study and all Ct values <40 were reported as positive without an established cutoff Ct. The endpoint dilutions negative by the PEDV RT-iiPCR but positive by the reference PEDV rRT-PCR had very high Ct values (35.4-37.5). When testing 10-fold serial dilutions of a PDCoV cell culture isolate, the PDCoV RT-iiPCR had equal sensitivity for endpoint detection to the reference PDCoV rRT-PCR . Overall, the PEDV RT-iiPCR and PDCoV RT-iiPCR had analytical sensitivities comparable to the reference PEDV rRT-PCR and PDCoV rRT-PCR. For evaluation of performances on clinical samples, nucleic acids were first extracted from 170 clinical samples using the MagMAX TM Pathogen RNA/DNA Kit and Kingfisher-96 instrument and then tested by the PEDV RT-iiPCR, PDCoV RT-iiPCR, and the reference PEDV rRT-PCR and PDCoV rRT-PCR. Comparing various PCRs using the same nucleic acid extracts eliminates variations on nucleic acid extractions and truly reflects the performance differences on each PCR itself. There were discrepant results on three samples between the PEDV RT-iiPCR and the reference PEDV rRT-PCR (Tables 6 a and 7) and zero discrepant results between the PDCoV RT-iiPCR and the reference PDCoV rRT-PCR (Tables 6 c and 7) , demonstrating excellent agreements between these PCR assays. However, it is impossible to extract nucleic acids from samples using the MagMAX TM Pathogen RNA/DNA Kit and Kingfisher-96 instrument in field situations. A portable POCKIT TM package includes reagents and Cubee TM mini centrifuge for taco TM mini nucleic acid extraction, lyophilized iiPCR reagents, and a POCKIT TM Nucleic Acid Analyzer. This ensures nucleic acid extraction and iiPCR testing can be completed within 1.5 h in field. Since under field conditions, taco TM mini extraction and iiPCR are combined for testing, we further compared the clinical performances of the taco TM mini extraction/RT-iiPCR system to MagMAX TM extraction/reference rRT-PCR system based on testing 170 clinical samples. Overall, 97.06% agreement was observed for the two PEDV PCR systems and 100% agreement for the two PDCoV PCR systems (Table 8) . Due to prevalence and co-circulation of PEDV and PDCoV in some areas, there are advantages of detecting and differentiating PEDV and PDCoV in a single sample using a multiplex rRT-PCR. In the present study, a duplex PEDV/PDCoV rRT-PCR including an internal control was evaluated. The duplex PEDV/PDCoV rRT-PCR was also highly specific and sensitive with LoD 95% of 7 copies per reaction for PEDV and 14 copies per reaction for PDCoV. Based on testing 170 clinical samples, the duplex rRT-PCR showed 97.65% agreement for PEDV detection compared to the reference PEDV rRT-PCR and 98.24% agreement for PDCoV detection compared to the reference PDCoV rRT-PCR. Sixteen samples that were positive for both PEDV and PDCoV as determined by the reference PEDV rRT-PCR and PDCoV rRT-PCR were successfully identified and distinguished by the duplex PEDV/PDCoV rRT-PCR. In this study, 170 clinical samples including fecal swabs, feces, intestines, and oral fluids were used to evaluate various PEDV and PDCoV PCRs. Occasionally, there is a need to test other specimen types such as feed and environmental samples for presence of PEDV and/or PDCoV. In fact, the reference PEDV rRT-PCR (Lowe et al., 2014; Madson et al., 2014) and the reference PDCoV rRT-PCR have been successfully used to detect PEDV and PDCoV RNA from feed and environmental samples at the ISU VDL. Although not evaluated in the current study, it is expected that the PEDV RT-iiPCR, PDCoV RT-iiPCR, and duplex PEDV/PDCoV rRT-PCR should be able to detect PEDV and/or PDCoV RNA present in feed and environmental samples as well. Studies to validate the on-site application of the RT-iiPCR/POCKIT TM system to help monitor the presence of PEDV in the environment is currently underway. In summary, the PEDV RT-iiPCR, PDCoV RT-iiPCR and duplex PEDV/PDCoV rRT-PCR assays developed and evaluated in the current study were overall comparable to the reference rRT-PCRs for detection of PEDV and/or PDCoV. The PEDV and PDCoV RT-iiPCRs are potentially useful tools for on-site detection and the duplex PEDV/PDCoV rRT-PCR provides a convenient method to simultaneously detect the two viruses and differentiate PEDV from PDCoV. Evidence of infectivity of airborne porcine epidemic diarrhea virus and detection of airborne viral RNA at long distances from infected herds Rapid detection of equine influenza virus H3N8 subtype by insulated isothermal RT-pCR (iiRT-pCR) assay using the POCKIT Nucleic Acid Analyzer Selection of a cutoff value for real-time polymerase chain reaction results to fit a diagnostic purpose: analytical and epidemiologic approaches Isolation and characterization of porcine epidemic diarrhea viruses associated with the 2013 disease outbreak among swine in the United States Pathogenicity and pathogenesis of a United States porcine deltacoronavirus cell culture isolate in 5-day-old neonatal piglets Pathogenesis comparison between the United States porcine epidemic diarrhea virus prototype and S-INDEL-variant strains in conventional neonatal piglets Evaluation of serological cross-reactivity and cross-neutralization between the United States porcine epidemic diarrhea virus prototype and S-INDEL-variant strains Complete genome sequence of a porcine epidemic diarrhea s gene indel strain isolated in france Origin, evolution, and genotyping of emergent porcine epidemic diarrhea virus strains in the United States Pathology of US porcine epidemic diarrhea virus strain PC21A in gnotobiotic pigs Pathogenicity of 2 porcine deltacoronavirus strains in gnotobiotic pigs Multiplex real-time RT-PCR for the simultaneous detection and quantification of transmissible gastroenteritis virus and porcine epidemic diarrhea virus Complete genome characterization of korean porcine deltacoronavirus strain KOR/KNU14-04 New variants of porcine epidemic diarrhea virus, China Full-length genome sequence of porcine deltacoronavirus strain USA/IA/2014/8734 Role of transportation in spread of porcine epidemic diarrhea virus infection, United States Insulated isothermal reverse transcriptase PCR (iiRT-PCR) for rapid and sensitive detection of classical swine fever virus Origin, evolution, and virulence of porcine deltacoronaviruses in the United States Pathogenesis of porcine epidemic diarrhea virus isolate (US/Iowa/18984/2013) in 3-week-old weaned pigs Rapid detection, complete genome sequencing, and phylogenetic analysis of porcine deltacoronavirus AT outbreak of porcine epidemic diarrhea virus in Portugal Porcine epidemic diarrhea virus RNA present in commercial spray-dried porcine plasma is not infectious to naive pigs Updated estimated economic welfare impacts of porcine epidemic diarrhea virus (PEDV) Investigation into the role of potentially contaminated feed as a source of the first-detected outbreaks of porcine epidemic diarrhea in Canada Chinese-like strain of porcine epidemic diarrhea virus PCR-based retrospective evaluation of diagnostic samples for emergence of porcine deltacoronavirus in US swine Porcine epidemic diarrhoea virus: a comprehensive review of molecular epidemiology, diagnosis, and vaccines Newly emerged porcine deltacoronavirus associated with diarrhoea in swine in China: identification, prevalence and full-length genome sequence analysis Emergence of porcine epidemic diarrhea virus in southern Germany Emergence of Porcine epidemic diarrhea virus in the United States: clinical signs, lesions, and viral genomic sequences Outbreak of porcine epidemic diarrhea in suckling piglets Complete genome sequence of a porcine epidemic diarrhea virus from a novel outbreak in belgium Effect of porcine epidemic diarrhea virus infectious doses on infection outcomes in naive conventional neonatal and weaned pigs Detection of white spot syndrome virus by polymerase chain reaction performed under insulated isothermal conditions Development of TaqMan probe-based insulated isothermal PCR (iiPCR) for sensitive and specific on-site pathogen detection Validation of a commercial insulated isothermal PCR-based POCKIT test for rapid and easy detection of white spot syndrome virus infection in Litopenaeus vannamei Distinct characteristics and complex evolution of PEDV strains, north america Complete genome characterization of porcine epidemic diarrhea virus in Vietnam Detection and genetic characterization of deltacoronavirus in pigs New variant of porcine epidemic diarrhea virus Development and evaluation of a duplex real-time RT-PCR for detection and differentiation of virulent and variant strains of porcine epidemic diarrhea viruses from the United States Rapid and sensitive detection of canine distemper virus by one-tube reverse transcription-insulated isothermal polymerase chain reaction Rapid and sensitive detection of canine distemper virus by one-tube reverse transcription-insulated isothermal polymerase chain reaction Rapid and sensitive detection of Feline immunodeficiency virus using an insulated isothermal PCR-based assay with a point-of-need PCR detection platform An insulated isothermal PCR method on a field-deployable device for rapid and sensitive detection of canine parvovirus type 2 at points of need Coronavirus genomics and bioinformatics analysis Discovery of seven novel Mammalian and avian coronaviruses in the genus deltacoronavirus supports bat coronaviruses as the gene source of alphacoronavirus and betacoronavirus and avian coronaviruses as the gene source of gammacoronavirus and deltacoronavirus This study was supported by the Iowa State University College of Veterinary Medicine Start-up fund awarded to Dr. Jianqiang Zhang. We are grateful to the Iowa State University Veterinary Diagnostic Laboratory faculty and staff for assistance with some testing.