key: cord-0689756-71znpuij authors: Reich, Noah; Lowe, Christopher F.; Puddicombe, David; Matic, Nancy; Greiner, Jesse; Simons, Janet; Leung, Victor; Chu, Terry; Naik, Hiten; Myles, Nick; Burns, Laura; Romney, Marc G.; Ritchie, Gordon; Champagne, Sylvie; Dooley, Kent; Sekirov, Inna; Stefanovic, Aleksandra title: Repeat virological and serological profiles in hospitalized patients initially tested by nasopharyngeal RT‐PCR for SARS‐CoV‐2 date: 2021-07-29 journal: J Med Virol DOI: 10.1002/jmv.27227 sha: 8c8e0411f19d0dbcc45469efc69a7b3f57cca95b doc_id: 689756 cord_uid: 71znpuij Real‐time polymerase chain reaction (PCR) for SARS‐CoV‐2 is the mainstay of COVID‐19 diagnosis, yet there are conflicting reports on its diagnostic performance. Wide ranges of false‐negative PCR tests have been reported depending on clinical presentation, the timing of testing, specimens tested, testing method, and reference standard used. We aimed to estimate the frequency of discordance between initial nasopharyngeal (NP) PCR and repeat NP sampling PCR and serology in acutely ill patients admitted to the hospital. Panel diagnosis of COVID‐19 infection is further utilized in discordance analysis. Included in the study were 160 patients initially tested by NP PCR with repeat NP sampling PCR and/or serology performed. The percent agreement between initial and repeat PCR was 96.7%, while the percent agreement between initial PCR and serology was 98.9%. There were 5 (3.1%) cases with discordance on repeat testing. After discordance analysis, 2 (1.4%) true cases tested negative on initial PCR. Using available diagnostic methods, discordance on repeat NP sampling PCR and/or serology is a rare occurrence. Molecular methods such as real-time polymerase chain reaction (PCR) are the mainstay for the diagnosis of COVID-19 in hospitalized patients. Although there are differences in molecular assays, analytical sensitivity for the detection of SARS-CoV-2 is high. 1 Most conflicting reports are on the clinical performance of PCR. Reports of a high rate of initial false-negative SARS-CoV-2 results by PCR, later diagnosed with COVID-19 by chest CT and repeat PCR, have emerged and continue to be reported. [2] [3] [4] [5] [6] [7] As SARS-CoV-2 serological testing has become available, this has presented another testing modality to retrospectively adjudicate suspected cases with negative PCR and a way to ascertain true cases of COVID-19. 8 The aim of our study is to estimate the frequency of discordance between initial nasopharyngeal (NP) PCR and repeat NP sampling PCR and/or serology in acutely ill patients admitted to the hospital. We further aim to use a panel diagnosis of COVID-19 in discordance resolution. Discordant cases were resolved using panel diagnosis to mirror the practical approach to testing in a clinical context. For example, discordant cases which tested negative on initial PCR and positive on repeat PCR, for which clinical likelihood for COVID-19 was high were deemed false negative by initial PCR. On the other hand, cases that tested positive on initial PCR and negative on repeat PCR, and had high likelihood clinical assessment were deemed true positive cases. During the study period, 323 patients had NP swabs tested by PCR, of these 290 (89.8%) initially tested negative and 33 (10.2%) tested positive. Included in the study were 160 patients who underwent additional testing by either repeat NP sampling PCR and/or serology. The median time since onset of symptoms to initial test was 3 days (range: 0-31). Repeat NP sampling PCR was performed on 123 patients for a total of 232 repeated tests (187 NP swabs, 18 sputa, 10 tracheal aspirates, 6 bronchoscopy specimens, 5 saliva, 2 nares, and 1 each of rectal swab, throat, saline gargle, and mouth rinse). The median number of repeat PCR tests was 2 (range: 1-8) per patient. None of the cases testing negative on initial NP PCR tested positive by an alternative sampling method. Serology was available for 91 patients, of which 18 tested "reactive" and 73 tested "nonreactive." The percent agreement between included patients' initial and repeat PCR was 96.7% (119/123), while the percent agreement between initial PCR and serology was 98.9% (90/91), with one PCR positive case testing nonreactive on serology (COI = 0.73). Serology was done at a mean of 69 days (range: 14-138 days) from symptom onset. In cases of discrepancy between initial PCR and repeat PCR or serology, panel diagnosis was used in discordance resolution. Discordance was observed in 5 (3.1%) of 160 patients, of which 2 had initial PCR positive followed by a negative PCR, 2 had initial PCR negative followed by positive PCR and 1 had positive initial and repeat PCR but was "nonreactive" on serology (COI = 0.73) ( Recent systematic reviews illustrate high heterogeneity and variability in estimated false-negative rates of NP swab PCR in the range of 1.8%-33%. 5, 6 The wide range of clinical diagnostic accuracy estimates are influenced by the timing of presentation, clinical syndrome, anatomical site of testing, quality of specimen collection, and reference standard used. 6, 15, 16 In our study initial testing was performed on NP swabs of patients requiring admission to hospital. Most patients were tested at 3 days since symptom onset and had on average of two repeat tests. In addition to repeat NP sampling PCR, we used serology as an independent diagnostic method. Panel diagnosis, consisting of two separate assessors with a good inter-rater agreement, was used in discordance analysis. We estimated percent agreement between patients' initial and repeat PCR of 96.7%, and initial PCR and subsequent serology of 98.9%. We were unable to calculate true sensitivity and specificity due to the lack of a true gold standard for COVID-19 diagnosis, a limited number of patients, and as additional testing was only done on a subset of the total cases. We identified 5 (3.1%) discordant cases. Two cases tested positive by initial PCR and negative by subsequent PCR, both were deemed high likelihood on panel diagnosis and PCR reversion part of the natural progression of the disease. One case with concordant initial and repeat positive PCR, tested negative on serology (COI = 0.73) was deemed to be a true case of COVID-19. This patient's immunosuppression as a result of heart transplantation may have been responsible for a blunted serological response. 17 Only 2 (1.4%) of initially negative PCR tests converted to positive. Similarly, a large study by Long et al. 18 found a low rate of discordance of initially negative PCR with subsequent PCR positivity at 3.5% but did not include serology in subsequent testing. In our first false-negative case the initial negative NP swab was taken 24 h after symptom onset and became positive 8 days later. PCR testing earlier than 48 h of symptom onset can lead to false-negative results as viral shedding can be below the level of detection. 6 The second false-negative case occurred in an elderly patient with severe viral pneumonia and a high clinical likelihood of COVID-19. The patient's first three NP swabs were negative until the fourth one tested positive 18 days after symptom onset. In severe infection viral load tends to be higher and peaks later; in this patient, it is possible that a lower respiratory specimen would have yielded better viral RNA recovery. 19 Difficulties with sputum production and concerns of aerosol generation with bronchoscopy present practical challenges in collecting lower respiratory tract specimens. In our T A B L E 1 Discordant case analysis of initial PCR and additional testing (repeat NP sampling PCR/serology) resolved by panel diagnosis The limitations of our study are the retrospective design and selection bias due to a hospital setting. Our data applies to sicker, hospitalized patients who tend to have greater viral shedding, possibly leading to improved rates of PCR detection. 19 Due to the small number of patients as only a subset of patients had repeat PCR or serology, we were limited in inferences to false-negative rates. We were also unable to determine the status of cases with no repeat testing performed but 95.4% of cases with initial negative PCR were deemed low clinical likelihood likely not warranting further testing. As our patient cohort had initial NP PCR testing on average 3 days since symptom onset, we could not comment on the potential for false-negative results at the time before or at symptom onset, though the rate of false negatives in this setting has been reported to be higher. 6 False-negative serology could have underestimated percent discordance, but in our dataset, this is a rare occurrence that primarily applies to highly immunocompromised individuals. 17 Last, clinical assessment of COVID-19 likelihood was not blinded to PCR results subject to incorporation bias, but at the same time reducing the risk of case misclassification (Figure 1 ). Molecular testing on NP swabs has a high correlation with repeat NP sampling PCR and serology and discordance remain a rare phenom- Considerations for diagnostic COVID-19 tests Correlation of chest CT and RT-PCR testing for coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases Detection of SARS-CoV-2 in different types of clinical specimens Evaluating the accuracy of different respiratory specimens in the laboratory diagnosis and monitoring the viral shedding of 2019-nCoV infections False-negative results of initial RT-PCR assays for COVID-19: a systematic review Variation in false-negative rate of reverse transcriptase polymerase chain reaction-based SARS-CoV-2 tests by time since exposure Diagnostics for SARS-CoV-2 infections Antibody responses to SARS-CoV-2 in patients with COVID-19 Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospectice cohort study China medical treatment expert group for covid-19. Clinical characteristics of coronavirus disease 2019 in China Clinical features of patients infected with 2019 novel coronavirus in Wuhan Statistical methods for assessing observer variability in clinical measures Temporal dynamics in viral shedding and transmissibility of COVID-19 Suboptimal Biological sampling as a probable cause of false-negative COVID-19 diagnostic test results Lack of antibodies to SARS-CoV-2 in a large cohort of previously infected persons Occurrence and timing of subsequent SARS-CoV-2 RT-PCR positivity among initially negative patients Viral load dynamics and disease severity in patients infected with SARS-CoV-2 in Zhejiang province, China, Janurary-March 2020: retrospective cohort study The authors would like to thank Dr. Christopher Ryerson, Dr. JaneMcKay, and the post-COVID-19 Recovery Clinic for their support of this work. We would like to extend our appreciation to Dr. Althea Hayden and Dr. Rohit Vijh for their guidance. We are also grateful to