key: cord-0685785-xo1cyzrg authors: Giles, Timothy; Yon, Lisa; Hannant, Duncan; Barrow, Paul; Abu-Median, Abu-Bakr title: Development of a DNA-based microarray for the detection of zoonotic pathogens in rodent species date: 2015-07-15 journal: Mol Cell Probes DOI: 10.1016/j.mcp.2015.07.005 sha: 59e6633d56807cdc811831e056d86e0da11bd5ad doc_id: 685785 cord_uid: xo1cyzrg The demand for diagnostic tools that allow simultaneous screening of samples for multiple pathogens is increasing because they overcome the limitations of other methods, which can only screen for a single or a few pathogens at a time. Microarrays offer the advantages of being capable to test a large number of samples simultaneously, screening for multiple pathogen types per sample and having comparable sensitivity to existing methods such as PCR. Array design is often considered the most important process in any microarray experiment and can be the deciding factor in the success of a study. There are currently no microarrays for simultaneous detection of rodent-borne pathogens. The aim of this report is to explicate the design, development and evaluation of a microarray platform for use as a screening tool that combines ease of use and rapid identification of a number of rodent-borne pathogens of zoonotic importance. Nucleic acid was amplified by multiplex biotinylation PCR prior to hybridisation onto microarrays. The array sensitivity was comparable to standard PCR, though less sensitive than real-time PCR. The array presented here is a prototype microarray identification system for zoonotic pathogens that can infect rodent species. Prompt detection of pathogens is a significant issue in diagnostic testing for both human and veterinary health. This is particularly relevant when slow-growing or fastidious organisms are involved and the limitations of some existing diagnostic tools are driving researchers to consider alternative methods, as demands on quantity and rapidity of testing methods are increasing [1] . Serological methods provide an indication of exposure to a pathogen and are best used for screening populations. However, they also require an adequate time post-infection/exposure for antibodies to develop and may be unable to distinguish between different strains or antigenic types of pathogen. Zoonotic pathogens make up the majority (75%) of emerging diseases and wildlife are a major source of these pathogens [2] . Early detection of pathogens in wild animals would be useful in identifying risk factors associated with disease transmission to humans or domestic animals, and this could help prevent a possible outbreak. It has also been suggested that prevention of disease, which could be aided by an effective surveillance system, is better than reacting to an outbreak, or to finding a cure [3] . Microarrays offer the advantage of testing large numbers of samples simultaneously, coupled with screening a single sample for multiple pathogens. Use of this technology would enable timely, accurate and inexpensive detection of pathogens, which could lead to more effective control of these infectious diseases, which has positive implications for public health [4] . There are a wide ranging number of potential applications for pathogen detection arrays; and have been used for the detection of novel pathogens, as in the case of severe acute respiratory syndrome (SARS) [5] , simultaneous detection of Newcastle disease virus and avian influenza virus in birds [6] and detection of viruses that can cause vesicular or vesicular-like lesions in livestock [7] . Although microarrays are used widely, the fluorescence-based glass slide arrays are relatively expensive. Alternatives to the glass slide microarray are the ArrayTube™ (AT) and ArrayStrip™ (AS) platforms from Alere Technologies GmbH (Jena, Germany). These are much less expensive, and can be used without highly specialised equipment [8] . The AT (up to 225 spots) and AS (up to 600 spots per well) platforms make the use of a small array surface of size 4 Â 4 mm placed on the bottom of a plastic vial or well. Hybridisation and analysis are simple and rapid, using standard laboratory methods, and hybridisation signals are detected following an enzyme-catalysed precipitation reaction [9] . The use of plastic tube-integrated arrays and fast non-fluorescent labelling and hybridisation protocols results in a system that is cost-effective, time saving, and allows high sample throughput, in a 96 well format [1] . There are currently no microarrays for the detection of multiple rodent-borne pathogens. The aim of this report is to explicate the design, development and evaluation of a microarray platform for use as a screening tool, which combines ease of use and rapid identification of a number of rodent-borne pathogens of zoonotic importance. An initial literature search was performed to identify zoonotic pathogens which are transmissible by rodents. A microarray was then developed to screen for the presence of these pathogens. Table 1 shows the list of pathogens to be screened for, including the source of any reference material if available. Unfortunately, not all of the pathogens for which the array was designed to detect could be sourced. Therefore the probes for, Hepatitis E Virus, Bartonella, MRSA, Rickettsia typhi and Streptobacillus monilliformis were not evaluated. RNA from an infected Rattus norvegicus sample was supplied but several attempts at PCR proved unsuccessful and it was concluded that the RNA had degraded too much to be of use. A further literature search was conducted to identify particular genes or target regions which had been previously used for identification purposes in other diagnostic tests such as PCR. The DNA sequences were obtained from the NCBI database and aligned using ClustalX2 (http://www.ebi.ac.uk/Tools/phylogeny/clustalW2_phylogeny/ help/faq.html#5) software. Oligonucleotide sequences (probes) were designed for each pathogen from regions targeted by speciesspecific or generic primers. Two freely available software packages were used for probe design: Unique Probe Selector (UPS) [10] and OligoWiz [11, 12] . Both types of software were used to compensate for any limitations in the other. OligoWiz, at present, can only be used to design probes for bacteria. An optimal length of 60-nucleotide probes was assigned, and parameters for both OligoWiz and UPS included crosshybridisation, delta-Tm, low-complexity, position and folding. An in silico analysis was performed on all the probes using the BLAST tool on the NCBI database to determine if cross-hybridisation would occur with any other known sequences. The selected probes were synthesised at Metabion International (Jena, Germany) with the following specifications: NH 2 modification at the 3 0 end, no modification at the 5 0 end, purification with HPLC, 0.04 mmol scale, and absolutely biotin-free. The AT platform was used for initial evaluation for individual pathogens, and the best performing probes were transferred to the AS platform making a pool of probes from different pathogens. For both platforms, each probe was directly spotted onto the array surface at a 15 mM concentration with each probe printed in duplicate. Generic primers were designed from conserved flanking regions of the target sequence using Primer3 (http://primer3.ut.ee/). Species-specific primers were designed from more variable regions of a sequence that were specific to certain pathogens. The amplicon size was set between 250 and 750 bases, with an optimum of 500 bases. Primer sequences for both multiplex PCR and real-time PCR can be seen in Table 2 . Several amplification methods were tested including sequenceindependent amplification [13] using a random pentadecamer primer and a primer tag, and sequence-dependent amplification using pathogen-specific primers. This sample mixture was then heated to 94 C for 2 min and then allowed to cool to 10 C in a thermal cycler for 5 min. The following 5.05 ml reaction mix was added to the sample mixture during its incubation at 10 C: 0.5 ml 10x Klenow buffer, 1.5 ml 3 mM dNTPs, 0.75 ml 0.1 M DTT, 1.5 ml 500 mg/ml BSA, 0.3 ml Klenow polymerase (Promega UK), 0.5 ml water. The reaction was left at room temperature for 5 min, followed by 1 min on ice. The mix was then heated to 94 C for 2 min, and rapidly cooled to 10 C in the thermal cycler for 5 min 10 ml of Klenow mix (1.0 ml 10x Klenow buffer, 8.7 ml water, 0.3 ml Klenow polymerase) was then added. For both RNA and DNA sequence-independent steps the mixture was then heated to 37 C for 8 min, and then held at 37 C for a further 8 min. This was followed by a rapid increase to 94 C for 2 min after which the mix was cooled to 10 C for 5 min, during which 1.2 ml of diluted Klenow (1:4) was added. The temperature was again increased to 37 C for 8 min followed by a hold of 8 min at 37 C, and then the reaction was terminated by placing the mixture on ice for 5 min. Standard PCR was then conducted using Primer B (GTT TCC CAG TCA CGA TC) (100 mM) to amplify the round A product with the following cycle parameters one step at 95 C for 10 s; 35 cycles of 30 s at 94 C, 30 s at 40 C, 30 s at 50 C, 2 min at 72 C and one final extension step of 72 C for 2 min. A 50 ml reaction mix was prepared from the following: 39.0 ml water, 1.5 ml 50 mM Magnesium chloride (MgCl 2 ) (Invitrogen UK), 5.0 ml 10x Table 2 Primers used during the evaluation of the arrays. The majority were designed during the study but others were obtained either from the literature or colleagues. Mg-free buffer (Invitrogen UK), 0.5 ml 25 mM dNTP mix, 0.5 ml Primer B, 0.5 ml Taq polymerase (5 U/ml) (Invitrogen UK) and 3.0 ml Round A product. Sequence-specific PCR was performed using a 50-ml reaction containing 37.5 ml of nuclease-free water, 2.0 ml of 50 mM MgCl 2 (Invitrogen UK), 5.0 ml of 10x Mg-free Buffer (Invitrogen UK), 1.0 ml of 25 mM dNTP mix, 1.0 ml of 10 mM forward primer, 1.0 ml of 10 mM reverse primer, 0.5 ml of Taq DNA polymerase (5 U/ml) and 2.0 ml of cDNA or DNA (optimal concentration 50 ng/ml). Cycling parameters were one step of 94 C for 2 min; 30 cycles of 30 s at 94 C, 1 min at 60 C and 1 min at 72 C and one final extension step of 10 min at 72 C. In addition the Qiagen Multiplex PCR Plus kit was tested with the sequence-dependent primer sets. This was carried out with both non-biotinylated and biotinylated primers. Multiplex PCR was performed using a 50-ml reaction containing 25 ml Multiplex Master Mix, 5 ml 10x primer mix (2 mM each primer) and variable volumes of water and template (50 ng/ml). The recommended protocol in the Qiagen Multiplex PCR Plus handbook was followed with cycling parameters of one step at 95 C for 5 min; 40 cycles of 30 s at 95 C, 90 s at 60 C and 90 s at 72 C and one final extension step of 10 min at 68 C. Real-time PCR was carried out using the Applied Biosystems 7500 Fast Real-Time PCR System. Real-time PCR was performed using a 10-ml reaction containing 5 ml of TaqMan ® Universal PCR Master Mix 2x (Life Technologies), 1 ml of 300 nM forward primer, 1 ml of 300 nM reverse primer, 1 ml TaqMan ® probe (2.5 mM), 1 ml of nuclease-free water and 1 ml of sample (or water as a negative control). The recommended protocol was followed with cycling parameters of one step at 50 C for 2 min, another step at 95 C for 10 min; 40 cycles of 95 C for 15 s and 60 C for 60 s. Each sample was run in triplicate. Prior to hybridisation of the labelled sample onto the array, the AS was conditioned by washing with 150 ml of water for 20 min at 30 C. After the water was removed using a pipette, a prehybridisation buffer (5x saline-sodium citrate (SSC), 0.1% sodium dodecyl sulphate (SDS), 4x Denhardt's solution) was pipetted into each well for 30 min at 50 C. Both washes were performed using a thermomixer (BioShake iQ, QUANTIFOIL Instruments GmbH, Jena Germany) at 550 rpm, which was used in all subsequent incubation steps unless otherwise stated. A 10-ml aliquot of the biotin-labelled sample was added to 90 ml of hybridisation buffer (5x SSC, 1% SDS, 4x Denhardt's solution). The mixture was denatured at 95 C for 3 min and then kept on ice. The denatured sample (100 ml) was then pipetted into the AS well and allowed to hybridise for 30 min at 55 C at 550 rpm. The sample solution was then removed and the AS was washed successively for 20 min at 60 C at 550 rpm with 150 ml wash buffer 1 (1x SSC, 0.2% SDS), wash buffer 2 (0.1x SSC, 0.2% SDS), and wash buffer 3 (0.1x SSC). This buffer was then removed and vacant binding sites on the microarray were blocked by incubation with a blocking solution (100 ml) of 2% biotin-free milk in PBS containing 1% bovine serum albumin (BSA) and 0.1% Tween™ 20 for 60 min at 30 C at 300 rpm. The blocking solution was replaced with 100 ml conjugation solution (Streptavidin Poly-Horseradish peroxidase (HRP) diluted 1:100 in the blocking solution), and the array incubated for 15 min at 30 C at 300 rpm. Postconjugation washes were performed using wash buffers 1e3 as described for the post-hybridisation washes. After removal of wash buffer 3, 100 ml of a tetramethylbenzidine (TMB)-hydrogen peroxide (H 2 O 2 ) solution, in this instance TrueBlue™ (Insight BioTechnology LTD, UK), was added and incubated for 10 min at 25 C without shaking. After removing the solution, the AS was then inserted into the ArrayMate and the array image was recorded with raw data generated. The recorded image was analysed using Alere's integrated IconoClust software and analysis script. Iconoclust processes the signals and automatically normalises the signal value after an algorithm processes the average intensity of the spot and the local background noise. The output range of the signals was between 0 and 1, with 0 being negative and 1 being the maximal possible signal value. The normalised intensity of the spots was automatically calculated by subtracting the local background noise from the average intensity of the automatically recognised spot. A 327 probe ArrayStrip was produced, and the number of probes per pathogen are given in Table 3 . During the evaluation stage, it was determined that sequence-independent amplification resulted in lower hybridisation signals on the array than sequencedependent amplification. Some of the pathogens (e.g. Cowpox, Toxoplasma gondii and Campylobacter jejuni), when amplified by their specific primers produced good quality, detectable, hybridisation signals, but when random amplification was used, they showed no or weak hybridisation. A DNA sample of C. jejuni for example was amplified using sequence-independent PCR and the product was then hybridised onto the array. A measurable signal was seen with 26.6% of the C. jejuni probes on the array. With specific amplification there was 100% probe hybridisation at significantly higher signal strength (data not shown). Fig. 1AeH shows the images recorded after hybridisation with a variety of Salmonella species following sequence-dependent and sequence-independent amplification. The spots indicated by arrows are the biotin markers, which act as assay controls. Numerous probes showed cross-hybridisation in these images, albeit at low signal intensities, so they were removed from the final version of the array. It is also apparent that the cross-hybridising probes were only visible in the images which show samples that had been amplified using sequence independent-amplification (Fig. 1AeF) . Table 3 The number of probes for each pathogen that were spotted on the WT_Rodent_Chip_03 ArrayStrip. Number of probes The images which show hybridisation following sequence-specific amplification were much cleaner (Fig. 1GeH) , and had the expected hybridisation profile. The three spots indicated by the rectangular box in all images except Fig. 1G are probes that were designed to hybridise with a wide range of Salmonella species. Fig. 1H shows the amplification of S. typhimurium with a set of primers designed to amplify this region which is common to multiple Salmonella species. S. Gallinarum (Fig. 1A) , S. Dublin (Fig. 1B) , S. Pullorum (Fig. 1C ), S. Enteritidis (Fig. 1D ), S. Hadar (Fig. 1E) , and S. typhimurium (Fig. 1FeH) were tested on the array. Although it was visible on the array, the signal strength is low in comparison to Fig. 1H . This is particularly noticeable for S. Dublin and S. Hadar from Fig. 1B and E. Both sequence-independent and sequence-specific amplification were used for S. typhimurium. The images produced after hybridisation can be seen in Fig. 1F and G. Fig. 1F shows sequenceindependent amplification, and the circled probes were designed to be specific for S. typhimurium. This set of probes did not show any detectable hybridisation in the other images so it appeared these were good probes for distinguishing SS. typhimurium from other Salmonella species. Fig. 1G shows the sequence-specific amplification with a set of primers designed to amplify the S. typhimuriumspecific region. The probes for all of the pathogens tested which produced a hybridisation signal can be seen in Table A .1 in the Appendix. The primer sets which performed well in singleplex PCR reactions were then tested in a multiplex reaction. As it is unlikely that a sample would contain all of the pathogens tested, the effectiveness of the primer mix in detecting a pathogen was tested using a sample of rodent liver DNA which was spiked with individual pathogen DNA (DNA concentration ranged from 1.66 to 112.5 ng/mL, and copy number from 2.33 Â 10 9 e2.09 Â 10 11 ). Fig. 2A shows a gel image of the result of amplification of individual pathogens from the spiked material when the multi-pathogen primer mix was used. Table 4 shows the pathogen detected in each lane from Fig. 2A . As can be seen from the figure, the majority of lanes had a strong band. The two bands in Lane 9 represent the specific S. typhimurium amplicons (663 bp) and the generic Salmonella amplicons (428 bp). This was expected, as the multipathogen primer mix had primers specific for S. typhimurium, and also had primers to amplify a region common to many Salmonella species. Fig. 2B shows the spots that hybridised after using the multiplex primer mix (with biotinylated primers) on a pooled nucleic acid sample from all pathogens for which reference samples were available. Although the band seen in Lane 12 for T. gondii was quite faint, careful analysis of the recorded image indicated that all of the pathogens in the sample, including T. gondii, hybridised with the expected specific probes on the array. The sensitivity of the array was tested by performing real-time PCR using serially diluted Yersinia pestis DNA. The pathogenic DNA in the sample was no longer detectable using real-time PCR (Fig. 3) at copy numbers less than 4.39 Â 10 2 . As expected, there was no amplification for the negative control sample. Samples in Fig. 3BeE (copy number 3.47 Â 10 9 , 1.76 Â 10 7 , 8.57 Â 10 4 , 4.39 Â 10 2 ) were detectable by real-time PCR. The DNA in sample B was detectable after 18 cycles. For samples C, D, and E the cycle number at which detection occurred was 24, 32 and 36, respectively. The DNA in sample F appeared to have been too low for realtime PCR to detect and no amplification was observed. The array images shown in Fig. 3 were produced after hybridisation of the products of standard PCR amplification. These were the same samples that were tested by real-time PCR for Y. pestis on the Yersinia_01 ArrayTube. The biotin markers on each array are indicated with an arrow. On the Yersinia_01 array only two probes were expected to hybridise with the primer set used (Y.pes/pPCP/ 8374/F Y.pes/pPCP/8902/R). As can be seen from the images produced after hybridisation, the two expected probes hybridised with samples B, C and D. For samples E and F there was no apparent hybridisation. Collecting good quality samples for disease surveillance can often be a time and cost intensive process. Therefore, it is important that any technology used is as efficient as possible. We report the development of a DNA microarray for simultaneous detection of multiple pathogens of rodents, comprised of 327 probes derived from a variety of genes in each of the target pathogens. The Fig. 2 . A. Agarose gel electrophoresis image produced after amplification of nucleic acid of individual pathogens using the multiplex primer mix. B. Profile produced after hybridisation of a mixture of all the pathogens following amplification with the multiplex primer mix for which reference samples were available. Table 4 The negative control sample and reference pathogen samples in lanes 1e12 from Fig. 2A . Pathogen Concentration ng/mL Amplicon size (bp) technology presented here represents a simple but effective system which is affordable and compatible with standard laboratory equipment, and has been used for a variety of purposes over recent years [1,14e18] . The design of oligonucleotide probes is a complex process for a variety of reasons, including identifying the best target sequences to be screened and understanding the thermodynamics of probetarget interactions during hybridisation [19] . An oligonucleotide length of 60 bp was selected, as several studies have indicated that this offers the best combination between specificity and sensitivity [20e22]. Shorter oligonucleotide probes (15e25 mers) have a very high specificity, but they have been criticised for having a lack of sensitivity, whereas longer oligonucleotides (40e90 mers) are thought to have a good sensitivity whilst maintaining a high specificity [19] . It has been reported that 60mer oligonucleotides have an eight-fold higher sensitivity than 25-mers [23] . Variation within microarray experiments can still occur regardless of careful probe design. The typical sources of variation can be broadly divided into three main categories: variation within the biological sample, the performance of the technology itself, and finally, variation in the spot signal measurements. The majority of variance in microarray experiments is generally biological rather than technical [24] . Arrays are generally made in batches and variation can occur between batches. These can include different probe concentrations, which can lead to incorrect conclusions being drawn from data [25] . Variation at the array production stage can occur for a number of reasons including, for example the particular printing pin used, the humidity, and temperature during printing. These variables can lead to slight differences in the amount of probe that is deposited on the slide surface, the amount that remains on the array surface after processing, and the level of deviation from the expected spot location. All of these factors can have an impact on the amount of labelled target that can bind to the probe, and on the efficiency of subsequent spot finding and data extraction steps [19] . The level of deviation from the expected location can result in the array reader making inaccurate readings, the signals of neighbouring probes becoming merged, or the spot can become invalid and cannot be accurately detected by the analysis software. In order to reduce the variability that is inherent in all biological experiments, experimental replication is essential. One obvious form of technical replication is through array probe replication. It is advantageous to at least have duplicates, or preferably multiples, of all probes spotted on the same array, however this may not be possible due to spotting density constraints. The precision of particular probe measurements will be more reliable if the spot intensities of the replicate spots are averaged for each sample [26] . To achieve an efficient hybridisation step, it is important to have probes with a narrow melting temperature distribution, because the hybridisation step takes place at the same temperature for all probes on the array [27] . The algorithms used in both OligoWiz and UPS are able to make minor adjustments to the length of each probe so that a narrow melting temperature range is achieved. Determination of melting temperature thresholds is a difficult task as this determines the conditions under which probes will bind to the target sequence. Melting temperatures can cause loss of signal if too high, and non-specific signal if too low [28] . As a single temperature is used during the hybridisation step, it is advisable that the narrowest melting temperature range be used to maximise signal detection [29] . The chip presented here represents a prototype microarray identification system for zoonotic pathogens that can infect rodents. The probes used on the microarray were based on genes that are unique to the pathogens selected. These genes were selected following a literature search to identify gene sequences which have been previously used to identify these pathogens, and a BLAST analysis to see if the sequences selected had similarity to any other pathogen sequences on the database. This is also the first report of biotinylated primers used in a multiplex format with up to 24 primer pairs. There was no apparent difference in the hybridisation signal produced when only a single pathogen was present in single and multiplex PCR reactions. More work needs to be done to determine the limits of detection and the sensitivity of the array, but as a proof of concept the array has demonstrated potential. Further improvements to this array could be made by obtaining reference material for pathogens which were unavailable and evaluating the probes for these pathogens. Whilst reference material was available for SEOV during the evaluation stage, several attempts at PCR proved unsuccessful. However, a number of rodent samples (nucleic acid was extracted from liver, kidney and lung of R. rattus and R. norvegicus, an aliquot of which was then pooled and amplified by multiplex PCR followed by hybridisation with the microarray) were screened on the array and two of these were identified as SEOV positive. This was later verified by both PCR and sequencing. While in silico analysis of the gene and resulting probe sequences are important in eliminating the possibility of crosshybridisation with other sequences already on the NCBI database, it does not rule out the possibility of cross-hybridisation with newly emerging organisms for which the gene sequence is unknown. As a result, microarrays can be used to identify novel as well as known pathogens. This can be achieved by designing probes at a genus level with additional probes designed for differentiating between species [30] . The presence of host nucleic acid in a sample presents another challenge in microarray experiments, as it can lower the sensitivity of the array. This occurs because in most situations the host DNA is present in much higher amounts than the pathogen nucleic acid, which makes the pathogen more difficult to detect. The sensitivity of an array may be improved by the removal of host nucleic acid by DNAses, i.e. enriching pathogenderived nucleic acid, using dedicated methods and kits for this purpose prior to PCR amplification [31] . The sensitivity on this array was less than that of real-time PCR, as has been previously demonstrated with other pathogen detecting microarrays [14, 32] , this leads to a trade-off between sensitivity and costeffectiveness. It would have been useful to have tested the array sensitivity for RNA pathogens as well. However, as mentioned earlier, there were no working RNA pathogens available during the evaluation stage. A critical step in the development of a microarray is sourcing reference samples with which the array can be evaluated. The design stage can be the deciding factor in the success of any microarray experiment and the choice of array platforms or probe types can be challenging. However, it is now becoming increasingly clear that when a careful design is followed, the results obtained with different platforms are likely to be comparable [19, 33, 34] . The user can decide whether to invest time and resources in developing their own arrays, utilise one of the commercial providers who can assist with array design and fabrication, or use off-the-shelf commercial arrays. The relatively low cost of screening for many pathogens simultaneously in a single sample is an economical and efficient approach for rapid and sensitive diagnostics. This may be of particular use for wildlife samples which may be small in volume and are often irreplaceable. A table showing the oligonucleotide sequence of the probes designed for use on the array. The amplification method is given, be it sequence-independent amplification or sequence-specific amplification with unique primers. A cut-off point of 0.4 for the signal intensity was used. Reference material was only available for the pathogens listed in Table A .1, therefore the probes designed to hybridise with SEOV or HEV for example were not evaluated. The probe mean signal is given along with the number of probes that hybridised in parentheses. The legend for the pathogens in Table A .1 is as follows: C.jej DNA microarray-based detection and identification of chlamydia and chlamydophila spp Philosophical transactions of the royal society of London, series B, biological sciences Is Prevention Better than Cure? Emergin pathogens: challenges and successes of molecular diagnostics Viral discovery and sequence recovery using DNA microarrays Simultaneous detection and differentiation of newcastle disease and avian influenza viruses using oligonucleotide microarrays, Veterinary Microbiol Microarray-based detection of viruses causing vesicular or vesicular-like lesions in livestock animals Optimized DNA microarray assay allows detection and genotyping of single PCR-amplifiable target copies Detection of herpesvirus and adenovirus co-infections with diagnostic DNA-microarrays UPS 2.0: unique probe selector for probe design and oligonucleotide microarrays at the pangenomic/genomic level OligoWiz 2.0-integrating sequence feature annotation into the design of microarray probes Probe selection for DNA microarrays using OligoWiz A method for the rapid sequence-independent amplification of microdissected chromosomal material Zoonotic chlamydiaceae species associated with Trachoma Optimised DNA microarray assay allows detection and genotyping of single PCR-amplifiable target copies Genotyping of Chlamydia trachomatis strains from culture and clinical samples using an ompA-based DNA microarray assay Rapid spoligotyping of Mycobacterium tuberculosis complex bacteria by use of a microarray system with automatic data processing and assignment More than classical Chlamydia psittaci in urban pigeons Microarray Technology in Practice Optimisation of oligonucleotide-based DNA microarrays Assessment of the sensitivity and specificity of oligonucleotide (50 mer) microarrays Assessing unmodified 70-mer oligonucleotide probe performance on glass-slide microarrays Optimisation of probe length and the number of probes per gene for optimal microarray analysis of gene expression Analytical specificity and sensitivity of a real-time polymerase chain reaction assay for identification of bovine mastitis pathogens Tackling the widespread and critical impact of batch effects in high-throughout data Microarray optimisations: increasing spot accuracy and Table A.1 (continued ) Probe ID. automated identification of true microarray signals Multiplex real-time PCR assay for detection of Entamoeba histolytica, Giardia intestinalis and Cryptosporidium spp A beginner's guide to microarrays An evaluation of custom microarray applications: the oligonucleotide design challenge Viral discovery and sequence recovery using DNA microarrays Development of a DNA microarray for simultaneous detection and genotyping of lyssaviruses Direct identification of chlamydiae from clinical samples using a DNA microarray assay-A validation study Are data from different gene expression microarray platforms comparable? Multiple-laboratory comparison of microarray platforms Comparison of PCR Binary Typing (P-BIT), a new approach to epidemiological subtyping of Campylobacter jejuni, with serotyping, pulsedfield gel electrophoresis, and multilocus sequence typing methods The FlgS/FlgR twocomponent signal transduction system regulates the fla regulon in Campylobacter jejuni Methods in Molecular Medicine. Diagnostic Virology Protocols Genome-wide DNA microarray analysis of Francisella tularensis strains demonstrates extensive genetic conservation within the species but identifies regions that are unique to the highly virulent F. tularensis subsp. tularensis Multiplex polymerase chain reaction assay for selective detection of Salmonella enterica serovar typhimurium