key: cord-0683956-3w1b2ubf authors: Ben-Dov, Iddo Z.; Tzukert, Keren; Aharon, Michal; Pri-Chen, Hadas; Oster, Yonatan; Oiknine-Djian, Esther; Wolf, Dana G.; Dranitzki Elhalel, Michal title: Response to tozinameran (BNT162b2) booster in twice-vaccinated kidney transplant and maintenance dialysis patients date: 2022-01-17 journal: J Nephrol DOI: 10.1007/s40620-021-01235-3 sha: d3f64682ee00c77fa45dadd0b6e4d86a7501e033 doc_id: 683956 cord_uid: 3w1b2ubf nan On 22-Sep-2021 the U.S. Food and Drug Administration amended the emergency use authorization for the Pfizer-BioNTech COVID-19 Vaccine (tozinameran) to allow the use of a single booster dose, to be administered at least 6 months after completion of the primary series in certain populations including individuals 18 years of age and older at high risk of severe COVID-19 [1] , while authorization for immunosuppressed patients was given 1 month earlier. However, boost vaccination of solid organ recipients commenced in Israel as early as mid-July. Additional at-risk populations, including elderly individuals, patients treated with maintenance dialysis and healthcare workers trailed briefly; the general adult population soon followed, resulting in increased protection from infection. Patients needing chronic renal replacement therapy are at risk for severe COVID-19 and have been shown to mount a lesser humoral response to mRNA vaccination [2] . In our single-center cohort we observed that reduced vaccine-elicited antibody levels in dialysis and kidney transplant patients were associated with increased infection rates [3] . Herein, we describe the short-term impact of booster administration in these patients, amidst a third wave of infections and deaths currently experienced in Israel primarily by the Delta variant, possibly amplified by waning immunity (Online Resource 1). Prior to initiation of vaccination we launched the COVID-19 mRNA Vaccine Immunogenicity in patients with end stage Renal Disease (COVIReD) prospective cohort study designed to investigate the long-term kinetics and implications of antibody response to COVID-19 vaccine and infection in this vulnerable population. The study was approved by the local ethical Committee and its methods and preliminary results have been recently published [3] . In this update, we report patients' humoral responses to booster vaccination. Antibodies were quantified using the LIAISON SARS-CoV-2 S1/S2 IgG test (DiaSorin, Sallugia, Italy). Risk factors for low antibody levels were assessed using a generalized linear mixed effects model accounting for repeated measurements (lme4/R statistical package). Infection risk was modeled with logistic regression. In total, we quantified anti-S1/S2 IgG levels at multiple time points in 183 maintenance dialysis patients, 280 kidney transplants and 74 controls not previously infected with COVID-19, of whom 82, 118 and 23, respectively, provided samples after receiving a vaccine booster. Figure 1a presents antibody median values across study groups and vaccination episodes. We had previously noted that with a most recent antibody level at or above 59 AU/ml no post-vaccination participant became infected, suggesting a COVID-19 protective cutoff [3] . Figures 1b and c show that prior to boosting (pre.v3), this level was achieved by 76% of controls, 35% of dialysis patients and 12% of transplant patients, while 8-117 days after booster injection respective rates were 100%, 91% and 56%. Risk factors for antibody levels < 59 AU/ml despite booster injection (control subjects excluded) were being in the transplant group, OR = 15.0 vs. dialysis (p < 0.0001), transitioning from dialysis to transplantation during the study period or vice versa, OR = 20.5 (p < 0.0001) and sampling sooner than 21 days post-booster injection, OR = 3.0 (p < 0.05). Age and sex were insignificant. Finally, 19 participants were diagnosed with COVID-19 since early July 2021; 2 controls, 4 dialysis patients and 13 transplant patients (Fig. 2) . Achieving an antibody level ≥ 59 AU/ ml, at any time point during the study, was associated with reduced risk of infection during the current surge, OR = 0.22 (p < 0.01), according to multiple logistic regression model. Age was also protective, OR = 0.97 per year (p < 0.05). Vaccination against COVID-19 was widely hoped to be the silver bullet against this deadly pandemic. However, starting July 2021, 6 months after mass vaccination in Israel, new infections surge, affecting also twice-vaccinated persons. In this report we show that a third dose of the BNT162b2 vaccine can effectively boost the antibody levels of high-risk chronic renal replacement therapy patients, as it did in healthcare controls. While the association between achieved binding antibody titers and resistance to viral infection is an open question, most patients have now reached a level likely to afford protection from disease, and specifically severe disease. Interestingly, the anti SARS-CoV-2 IgG levels were higher after the third dose than after the previous doses which may hint that the latest immune response may be more robust and hopefully sustainable, even in immunecompromised patients. In fact, kidney transplant recipients showed the most striking enhancement in humoral response to the booster dose, exhibiting an almost sixfold increase in the number of patients developing a protective level of antibodies. This is greater than previously described [4] , and supports repeated vaccination of non-responsive immunosuppressed patients. However, many transplant patients remain below threshold in terms of antibody levels even after boosting. In our transplant clinic we did not lower immunosuppression prior to the booster dose, although various transplant centers contemplated transiently reducing immunosuppression to facilitate response [5] . Our experience is consistent with "real life" practice and may be of use to guide practical recommendations for kidney patients receiving immunosuppression or dialysis. Publisher's Note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations. No Post-booster COVID-19? LIAISON SARS-CoV-2 S1/S2 IgG, AU/mL Yes Fig. 2 Anti SARS-CoV-2 S1/S2 IgG levels in patients and controls who experienced COVID-19 infection after receiving a booster dose of the BNT162b2 vaccine (right violin plot, n = 19) versus those who were not infected (left violin plot, n = 479). The green dashed line represents the proposed 59 AU/ml protective cutoff. Statistical significance was not affected by adjustment for age, sex or study group (not shown) (colour figure online) @US_FDA (2021) FDA authorizes booster dose of Pfizer-BioN-Tech COVID-19 vaccine for certain populations The efficacy of COVID-19 vaccines in chronic kidney disease and kidney transplantation patients: a narrative review Impact of tozinameran (BNT162b2) mRNA vaccine on kidney transplant and chronic dialysis patients: 3-5 months followup Safety and immunogenicity of a third dose of SARS-CoV-2 vaccine in solid organ transplant recipients: a case series Immunosuppression reduction when administering a booster dose of the BNT162b2 mRNA SARS-CoV-2 vaccine in kidney transplant recipients without adequate humoral response following two vaccine doses: protocol for a randomised controlled trial (BECAME study)