key: cord-0682347-ggiksho5 authors: CHEN, Guo Min; JI, Jia Jia; JIANG, Shuai; XIAO, Ya Qi; ZHANG, Ren Li; HUANG, Da Na; LIU, Hui; YU, Shu Yuan title: Detecting Environmental Contamination of Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Isolation Wards and Fever Clinics* date: 2020-12-31 journal: Biomedical and Environmental Sciences DOI: 10.3967/bes2020.130 sha: ca45f465a4bf36662ad3061891fd29b9933b54ac doc_id: 682347 cord_uid: ggiksho5 nan is an acute respiratory disease with an incubation period of 1 to 14 d, which is caused by a novel coronavirus (SARS-CoV-2), which has spread throughout China and worldwide. Different from SARS, MERS, and influenza, the dominant clinical manifestations of COVID-19 are fever and cough, whereas upper respiratory symptoms and gastrointestinal symptoms are rare. Moreover, the elderly and those with underlying diseases become more seriously ill after infection [1] . SARS-CoV-2 is highly transmissible in humans and is characterized by a risk of nosocomial transmissions [2] . Compared with the general population, healthcare workers (HCWs) are a special population who have a particularly higher risk of acquiring COVID-19 infection because they are exposed to biological risk factors during their daily work. Specifically, COVID-19 spreads through closerange contact with patients via respiratory droplets and secretions, and also through direct contact but with a low infective dose [1] . Additionally, aerosol, fecal-oral, and bloodborne transmission of SARS-CoV-2 have also been considered potential threats to the safety of HCWs, even though the possibility of these transmission routes remain controversial [3] . It has been reported that many first responder HCWs worldwide have been infected with COVID-19 since the disease outbreak [4, 5] . However, the transmission mode and extent of environmental contamination of SARS-CoV-2 have not been fully investigated. Therefore, this study was conducted in isolation wards and fever clinics during the Shenzhen outbreak to examine whether environmental contamination of air and surfaces could explain the ongoing risk of nosocomial transmission of SARS-CoV-2. Using novel air sampling techniques and conventional surface swabbing, samples were obtained from Shenzhen Nanshan People's Hospital and the Third People's Hospital of Shenzhen. The Third People's Hospital of Shenzhen is the only hospital designated to treat COVID-19 patients in Shenzhen. Air sampling was performed in the waiting rooms and an outpatient room of fever clinics in Nanshan People's Hospital on March 11, 2020, using two types of bioaerosol samplers. The Coriolis micro air sampler (Bertin Technologies) is a cyclone-based air sampler and collected air for 30 min at 300 L/min into a conical vial containing 15 mL PBS buffer [6] . The Sartorius MD8 microbiological sampler collected air for 60 min at 50 L/min, with a gelatin membrane filter [7] . After the room had been sealed for 20 min, both samplers were set 1.2 m above ground for sampling. The same samplers and methods were applied to the air sampling performed in four isolation wards in the Third People's Hospital of Shenzhen between March 13 and 14, 2020. Additionally, the samplers were set 0.5 m from the patients, who were requested to not wear masks and to cough periodically during sampling. In parallel, environmental swabs were also aseptically collected from frequently touched surfaces in wards using medical cotton swabs premoistened with Hanks solution. Samples were collected before routine cleaning. For isolation wards, cleaning is performed every 4 h with 2,000 mg/L chlorine disinfectant for high-touch areas (including floor and For fever clinics, cleaning was performed twice daily for 1 h each time, using ultraviolet light (Philips TUV 36W/G36 T8). Air conditioning filter swab samples and 200 mL condensate water samples were also collected from the air conditioner room of the floor with negative-pressure wards. Immediately after collection, the samples were stored in biohazard logistic boxes, couriered to a biosafety level 3 (BSL-3) laboratory, and stored at -80 °C. Specific real-time reverse transcriptasepolymerase chain reaction (RT-PCR) analysis was completed within 24 h, The assay that was used to detect the presence of SARS-CoV-2, involved amplifying two different targets within the SARS-CoV-2 genome, the ORF1ab gene (with high specificity) and N gene (with high sensitivity) [8] . Briefly, after RNA extraction, 5 μL of viral RNA extracted from the sample was added to the RT-PCR mixture, which contained 12 μL of the nucleic acid amplification reaction solution (magnesium ion and nucleotide mixture), 4 μL of the enzyme mixture (DNA polymerase, reverse transcriptase, UNG enzyme), and 4 μL of the ORF1ab/N reaction solution (primers and probes for the ORF1ab and N genes and the internal reference gene RNase P), in a final volume of 25 μL. For RT-PCR against the ORF1ab gene, the following primers were used: forward, 5′-CCCTGTGGGTTTTACACTTAA-3′; reverse, 5′-ACGATT GTGCATCAGCTGA-3′; and probe, 5′-FAM-CCGTCTG CGGTATGTGGAAAGGTTATGG-BHQ1-3′. For RT-PCR against the N gene, the following primers were used: forward, 5′-GGGGAACTTCTCCTGCTAGAAT-3′; reverse, 5′-CAGACATTTTGCTCTCAAGCTG-3′; and probe, 5′-FAM-TTGCTGCTGCTTGACAGATT-TAMRA-3′. Cycle threshold (Ct) values, which are the minimum number of cycles required to generate a fluorescent signal that can be detected, provide quantitative information for SARS-CoV-2 that correlate with viral load in an inversely proportional relationship. The thermocycler conditions used were as follows: 50 °C for 10 min for reverse transcription; 95 °C for 5 min for initial denaturation, and then 40 cycles of 95 °C for 10 s, 55 °C for 40 s for the denaturation, amplification, and detection of fluorescence. The result was considered positive if both target were positive (Ct value ≤ 38), and suspiciously positive if only one target test result. Positive controls (viruslike particles specific to the RNase P genes and plasmids containing ORF1ab and N-specific fragments) and negative controls (saline) were also set up to avoid misjudging the results. Patient data, including date of onset, symptoms, severity of illness, and the most recent SARS-CoV-2 PCR clinical test results of patients prior to sampling, were collected in all wards where environmental sampling was performed. Patient informed consent and Institutional review board approval were obtained before the environmental samplings were conducted, and the robustness of the experimental protocol was examined in the laboratory. Four types of facility were sampled, including a waiting room for fever clinics and an outpatient room in Nanshan People's Hospital, four patient rooms and an air conditioner room on the floor with the negative-pressure wards in Shenzhen Third People's Hospital. Characteristics of the patients and their illness at the time of sampling are summarized in Table 1 . Note. SARS-CoV-2, acute respiratory syndrome coronavirus 2; RT-PCR, reverse transcriptase-polymerase chain reaction. a Disease severity was considered severe if both lungs were involved and oxygen supplementation was needed. The results of environmental sampling tests for SARS-CoV-2 by RT-PCR are shown in Table 2 . Among the 12 air samples collected from Shenzhen Third People's Hospital and Nanshan People's Hospital using either Coriolis micro air sampler (Bertin Technologies) or the Sartorius MD8 microbiological sampler, all were PCR-negative for SARS-CoV-2. For environmental surface swab samples from isolation wards, samples from 24 environmental surfaces that were frequently contacted by 4 patients were collected. Only one (4%) of the sampled sites returned positive results, which was the mask of a patient with a Ct values of 33 and 31 for the ORF1ab and N genes. One (4%) of the sampled sites returned suspiciously positive results, the oxygen pump tube by the patient's bed, which had a relative higher Ct value of 37 for the ORF1ab gene compared to the value of the positive mask sample, while a Ct value for the N gene was undetected. Both positive and suspiciously positive samples were taken from patient A, whose disease severity was considered severe because both lungs were involved and oxygen supplementation was needed. Furthermore, the disease severity of patients B, C, and D were relatively mild given that those patients did not require oxygen supplementation. Fifteen surface swab samples of these patients, which were collected at patient isolation wards returned negative results. Moreover, air conditioning filters and condensate water collected from the air conditioner room on the floor with negativepressure wards were negative. The positive swab sample from the mask demonstrated the possibility of transmitting SARS-CoV-2 via human respiratory droplets. Viral droplets formed by patients coughing and sneezing or asymptomatic infections can cause disease transmission if inhaled at close range. Furthermore, SARS-CoV-2 RNA was only detected on the mask of a patient when sampling was performed within a few days of symptom onset (patient A), compared with when other patient were investigated. This is consistent with the findings of an observational cohort study, which found that the viral load of SARS-CoV-2 in saliva samples was highest during the first week of symptom onset and then gradually declined [9] . The detection of SARS-CoV-2 RNA on oxygen pump tubes indicated that particular attention should be paid to the cleaning of treatment equipment because cleaning may intentionally be less thorough due to its shape and moisture sensitivity. Compared with the Ct value of the mask of the same patient (33 for ORF1ab), the Ct value of the oxygen pump tube was greatly increased (37 for ORF1ab ), i.e., the viral load is lower, which highlighted the necessity of using masks for preventing public health crises and protecting medical workers. Generally, undetectable or very low rates of positivity were found for all environmental samples, including those in all hightouch areas, which showed the effectiveness of cleaning measures taken by hospitals. Air samples taken by wet air sampling and dry air filtering were both negative. This may be caused by the concentration of aerosolized virus being too low to be detected effectively, because the wards and fever clinics were well ventilated, and the patient density was low at the time of sampling. The possibility of aerosol transmission needs to be further studied. There were several limitations to this study. First, for suspected positive clinical results, repeated sampling and testing are required for confirmation. However, it is not applicable for environmental samples due to the non-repeatable characteristics of environmental sampling. Second, only a limited number of wards and fever clinics were investigated because of operational limitations. Third, viral culture was not performed on positive samples to demonstrate their viability. This study may explain the apparent risk of nosocomial infection in countries where high level protection masks are insufficient. Adopting effective sanitization for high-risk areas and using high level protection masks for medical workers who have direct contact with high risk areas or COVID-19 patients are essential to ensure the safety of healthcare workers. Note. SARS-CoV-2, acute respiratory syndrome coronavirus 2; ECG, electrocardiogram; ND, not detected; RT-PCR, reverse transcriptase-polymerase chain reaction. a The volume of each air sample taken by the Sartorius MD8 microbiological sampler consisted of 300 L of air. b The volume of each air sample taken by the coriolis micro air sampler consisted of 9,000 L of air. c The swab of a face shield was taken from a medical worker who had been working in the room of patient A for 4 h. Received: April 7, 2020; Accepted: July 25, 2020 The origin, transmission and clinical therapies on coronavirus disease 2019 (COVID-19) outbreak-an update on the status Clinical characteristics of 138 hospitalized patients with 2019 novel coronavirus-infected pneumonia in Wuhan, China Detection of SARS-CoV-2 in different types of clinical specimens COVID-19: protecting health-care workers Early Transmission dynamics in Wuhan, China, of novel coronavirus-infected pneumonia Isolation of H5N6, H7N9 and H9N2 avian influenza A viruses from air sampled at live poultry markets in China An assessment of Sartorius MD8 microbiological air sampler Molecular diagnosis of a novel coronavirus (2019-nCoV) causing an outbreak of pneumonia Temporal profiles of viral load in posterior oropharyngeal saliva samples and serum antibody responses during infection by SARS-CoV-2: an observational cohort study Detecting environmental contamination of SARS-CoV-2