key: cord-0620978-eusx8yr0 authors: Zografopoulos, Ioannis; Konstantinou, Charalambos; Hatziargyriou, Nikos D. title: Distributed Energy Resources Cybersecurity Outlook: Vulnerabilities, Attacks, Impacts, and Mitigations date: 2022-05-23 journal: nan DOI: nan sha: 5f711d12fb75ff0f0d086e54c819f0ff67fb5b02 doc_id: 620978 cord_uid: eusx8yr0 The digitalization and decentralization of the electric power grid are key thrusts towards an economically and environmentally sustainable future. Towards this goal, distributed energy resources (DER), including rooftop solar panels, battery storage, electric vehicles, etc., are becoming ubiquitous in power systems, effectively replacing fossil-fuel based generation. Power utilities benefit from DERs as they minimize transmission costs, provide voltage support through ancillary services, and reduce operational risks via their autonomous operation. Similarly, DERs grant users and aggregators control over the power they produce and consume. Apart from their sustainability and operational objectives, the cybersecurity of DER-supported power systems is of cardinal importance. DERs are interconnected, interoperable, and support remotely controllable features, thus, their cybersecurity should be thoroughly considered. DER communication dependencies and the diversity of DER architectures (e.g., hardware/software components of embedded devices, inverters, controllable loads, etc.) widen the threat surface and aggravate the cybersecurity posture of power systems. In this work, we focus on security oversights that reside in the cyber and physical layers of DERs and can jeopardize grid operations. We analyze adversarial capabilities and objectives when manipulating DER assets, and then present how protocol and device -level vulnerabilities can materialize into cyberattacks impacting power system operations. Finally, we provide mitigation strategies to thwart adversaries and directions for future DER cybersecurity. In the last decades, electric power systems (EPS) have undergone significant transformations (e.g., decentralized generation, digitization of customer services, smart grid initiatives, etc.) to meet increasing power demand and provide economically and environmentally friendly energy. Renewable energy resources (RES) harnessing wind, solar, and thermal energy have been used to improve energy efficiency while meeting stringent carbon emission regulations [1] . The shift towards more sustainable grid architectures has also boosted the adoption of distributed energy resources (DER). According to the definition of the North American Electric Reliability Corporation (NERC), DERs are distribution-level resources that produce electricity and are not part of the bulk EPS [2] . DERs can leverage renewable or non-renewable resources for power generation. Typical DER examples include i) distributed rooftop solar photovoltaic (PV), ii) wind (micro)turbines, iii) diesel generators, iv) microgrids, v) controllable loads and demand-response, vi) electric vehicles (EV) and electric transportation, and vii) behind-or in front-of-themeter energy storage (e.g., battery energy storage systems -BESS, flywheels, etc.) connected on the distribution transformer secondary [2] . DER-integrated systems and devices are classified into different categories based on their operation principles, e.g., generation, energy storage, combination of the two, and controllable loads. For instance, solar panels and wind turbines DERs belong to the generation category [3] , batteries and electric vehicles fall into energy storage, combined cooling, heating, and electric water heaters are examples of controllable loads [4] , and inverter-based resources (IBR) can be used in both generation and storage setups. The rapid integration of DERs highlights their importance for future EPS. Furthermore, the high demand for DERs has resulted in a decrease in the cost of solar cells and lithium batteries production, which has expedited their adoption. Studies forecast that the global DER generation capacity is expected to grow from 132.4 GW in 2017 to 528.4 GW in 2026 [5] . Similar observations can be made for BESS. For example, in the United States (U.S.), BESS are expected to grow from 1.2 GW in 2020 to nearly 7.5 GW in 2025, while developing into a market of $7.3 billion annually [6] . Strategic placement of DERs adjacent to consumers can take advantage of on-site generation and minimize utility costs by deferring investments for the expansion of the power system network. DER generated power does not need to be transferred from remote bulk generation facilities, thus minimizing energy losses and providing economically dispatchable power to consumers. For example, DERs could be harnessed to reduce the transmission system operator (TSO) ancillary market costs, which increased by almost 70% during the 2020 COVID-19 lockdown period [7] . This was due to the the stochasticity of the real-time power demand, and the requirement of maintaining frequency stability and energy reserves, while primarily relying on intermittent generation of renewable resources, which created a very competitive power market [7] . DERs can also enhance EPS reliability through DER-supported autonomous functions. With higher DER penetration, the consequences of disastrous events, e.g., blackouts, extreme weather, cyberattacks, etc., could be averted or effectively mitigated [8] . For instance, DERs could have helped curtail the impacts of extreme weather events similar to the Texas snowstorm in February 2021 [9] . The efficient, flexible, and autonomous attributes that DERs possess render them invaluable pillars for the EPS critical infrastructure (CI). DERs are a crucial part of the EPS, thus, they can become prominent targets. Attackers could compromise the remote communication and control of DER capabilities, and propagate the impact of their attacks to the rest of the system. The effects of nonfunctional and/or maliciously controlled EPS can be dire. The cybersecurity incident in Utah, U.S. on 5 March 2019 is a prime example of how attackers can corrupt communications and compromise grid services. In the 2019 Utah incident, attackers exploited vulnerabilities in security firewall devices (residing on the operator side) to halt arXiv:2205.11171v1 [cs.CR] 23 May 2022 Fig. 1 : Utility-to-DER interconnection. communications between system operators and distribution wind and solar utilities [10] . The impact of this denial-ofservice (DoS) attack caused loss of visibility of power grid assets and could have caused interruptions of electrical system operations [11] , [12] . To overcome disruptive cyberattacks comprehensive security investigations should be performed factoring in the cyberphysical DER architecture, which could be targeted on either the cyber or physical threat plane. On the cyber level, protocols facilitate the essential communication transpiring between DERs and utility aggregators for DER monitoring and control purposes (Fig. 1 ). Information and communication technologies (ICT) enable communication between DER assets and DER management systems (DERMS). Typically, wired or wireless communication protocols are used, such as the IEEE 1815-Distributed Network Protocol (DNP3), Sunspec Modbus, open automated demand response (OpenADR), and IEEE 2030.5 (Table I) . Embedded devices on the DER side handle monitoring and remote DER asset control requests. Insecure remote communication expands the EPS threat surface since adversaries can exploit communication protocol weaknesses to mount attacks, e.g., DoS, man-in-the-middle (MitM), etc. The situation is aggravated by the fact that many of the communication protocols being used have known vulnerabilities. Exploiting those vulnerabilities can compromise system operation if malicious commands are issued to DER devices (Section III-A). On the physical layer, the device-level consists of the embedded architectures (e.g., controllers, actuators, gateways, converters, etc.) and their fundamental components (e.g., hardware, firmware, software, etc.) that support the control of DERs and could constitute another weak link for the system security. Most of these embedded devices are built using commercial off-the-shelf (COTS) components. As a result, embedded device-related vulnerabilities in the hardware and software level can be ported to DER systems. Apart from the vulnerabilities of COTS and the computational resource constraints of embedded systems (which can limit the sophistication of the employed security schemes), their trustworthiness cannot be attested either. The heterogeneity of embedded systems aggravates their security posture and makes verifying the supply-chain trustworthiness often infeasible. Multiple third-party vendors provide intellectual property (IP) blocks which are then integrated by fabrication facilities during their manufacturing stages [13] . The severe impact of supply-chain attacks was demonstrated during the Solarwinds incident in December 2020, which targeted network management systems around the globe. Namely, 18k of the 300k Solarwinds customers were running vulnerable versions of the Orion Interoperable communication framework for secure information exchange in industrial systems (e.g., SCADA) [23] Modbus protocol extension for DER parameters (e.g., power, voltage) and ancillary services monitoring and control [24] OpenADR Energy market management standard regulating demand-response via signals to DERs and other controllable devices [25] IEEE 2030.5 Smart energy profile application standard and default protocol for DER management [26] platform, including the U.S. Department of Treasury, U.S. Department of Energy, U.S. Department of Defense, 425 of the U.S. Fortune 500, as well as the cybersecurity firm FireEYE [14] , [15] . The severe blow of the Solarwinds supply-chain attack on CI networks forced the White House to issue an executive order instructing the improvement of cybersecurity in all federal government networks [16] . Overall, supply chain related dependencies arise as potential threat vectors, especially given the lack of security controls when designing or integrating COTS software or hardware during system design. Sophisticated cyberattacks targeting the pillars of CI are gaining popularity. Such attacks can have severe impacts on business operations like the Solarwinds incident and the colonial pipeline ransomware attack which halted the delivery of transport fuel to the Atlantic coast [17] . Moreover, attacks on public health are rising, such as the attack on the Florida water treatment plant [18] , attacks on hospitals during COVID-19 [19] , [20] , etc. The aforementioned incidents underline that CI protection needs to become the epicentre of cybersecurity research. As shown in Fig. 2 , multiple cyberattacks targeting the energy and other critical infrastructure sectors have been reported in the literature. Renewable and distributed resources are evidently becoming prominent targets. This was the case in [12] , where a firmware vulnerability in operational technology equipment (OT), specifically CISCO firewalls, was exploited to cause a DoS that disrupted power system communications and impeded the control of small renewable generation facilities. In order to combat DER-related threats, existing efforts such as the DER cybersecurity framework (DERCF) by the National Renewable Energy Lab (NREL) [21] , and the renewable energy and distributed systems integration (RDSI) program by Sandia National Lab (SNL) [22] , place grid security as one of their core initiatives. In this paper, we focus on cyberattacks targeting DER assets. DERs play a significant role in reliable and resilient EPS operation, given their autonomous capabilities (e.g., defensive islanding) and ancillary service provision (e.g., voltage/frequency regulation, active/reactive power compensation, etc.) [27] . However, DER security is contingent upon the utilized communication protocols and control schemes (e.g., user, aggregator, or utility -defined) as well as the inherent DER device architectures (e.g., vendor-specific). Thus, we first discuss the motives and resources of adversaries, and then focus on DER attacks at the i) communication protocol and ii) device level of such assets. Last, DER protocol and device -level vulnerabilities, attacks, impacts, and mitigation strate- gies are presented. The roadmap of this work is as follows. Section II presents the adversary and attack models. Section III outlines the protocol and device vulnerabilities, which, if exploited, can lead to cyberattacks, and discusses potential impacts and mitigations. Finally, Section IV concludes the paper and provides challenges that need to be addressed for a secure future power system. This section identifies high-value targets in DER-integrated systems and attack vectors with their corresponding cyberthreats. Assumptions about adversary capabilities and knowledge, and attack specifics following the threat model methodology are introduced in [28] . Furthermore, we compile the threat vectors along with the methodology followed to materialize attacks, and outline some common cyberattack definitions, which are further used in Section III. The following discussion delineates our assumptions regarding adversarial system knowledge and capabilities, as well as how they correlate with attacks targeting DER grid communications and devices. Adversaries could rely on publicly available information to perform their attacks [29] . Additional knowledge can be acquired after a system asset or device is compromised and/or while a cyberattack is propagated in the system. Knowledge can also be obtained by accessing unsupervised hosts on enterprise networks [30] , [31] , by gaining unauthorized access to data shared among DER devices. Other methods include eavesdropping traffic, target device IP address identification, port scanning, applicationlevel protocol exploitation [30] , [32] , ciphertext decryption, intercepting exchanged data [33] , or malicious insiders. Equally important to the attacker knowledge assumptions are the adversarial capabilities. Adversarial capabilities consider the access to DER assets within a given system. For example, an attacker might be able to connect to remote DER devices through legitimate Bluetooth or speedwire connections (i.e., insider case) [34] . Additionally, attackers could possess or have physical access to EV charging stations or to the local area network (LAN) over which DERs communicate [35] . In the latter case, such access could be achieved if attackers can infiltrate the LAN using proxy attacks on PCs, routers, surveillance systems, etc. [36] . Additionally, other attacks assume that the adversary is capable of compromising peripheral controllers and deploy custom firmware [37] (e.g., change voltage measurement values in human-machine interfaces (HMIs) [32] ). As a result, attackers can remotely manipulate and jeopardize various physical assets (e.g., distribution level devices, DERs, substation equipment, etc.) [29] . Attackers are assumed to have sufficient computational resources -especially when supported by criminal organizations or nation-state actors -to crack passwords and decrypt power grid data. For example, it is reported that by brute-forcing PIN codes of wind farm control panels, attackers could send malicious commands to wind turbines impacting grid operation [35] . Of equal importance to the adversary model, the attack model specifics are essential for the threat model description (e.g., in retrospection of past cyberattack incidents). Although we do not provide one-to-one mappings between attacks (presented in this study) and each corresponding attack model component, their key aspects -influencing impacts and mitigation strategies -are described in Sections III-B and III-A. Attack model information is crucial when establishing the requirements for a vulnerability to develop into a system compromise, its potential impact, and mitigations or other methods to overcome such adversity. Following the attack methodology in [28] , the attack model can be considered as being composed of the following six elements, i) the attack frequency, ii) the attack reproducibility, iii) the functional level being attacked in the system, iv) the attacked asset, v) the techniques being used, and vi) the attack premise. For instance, some attacks might have to be performed iteratively and reproduced multiple times to compromise the system behavior. This could be the case with packet replay, DoS, and MitM attacks, where attacks might aim to spoof DER communications or exhaust DER protocols and/or device resources causing intermittent, slow or loss of communication thereof [38] . The attack functional level and the targeted DER assets notably differ when considering communication protocol and device attacks. Typically, cyberattacks targeting DER devices could be assigned to the levels 0 and 1 including process sensors, actuators, and controllers, while attacks on the communication, coordination and control fabric of DER systems target the higher levels (i.e., 3, 4, and 5) of the Purdue model [39] . Furthermore, distinctions are necessary when investigating the attack techniques and the premise of cyberattacks. A detailed presentation of the most common attack techniques used by adversaries (constantly updated with new incidents) can be found in [40] . The attack premise delineates whether the attack is performed in the cyber or physical system domain. For our study, identifying the attack premise is fairly intuitive since DER protocol attacks are limited to the cyber domain, while DER device compromises could span both the cyber and the physical domains. Further information is provided in literature on how more complex cyberattacks could target the cyber and physical domains while exploiting diverse attack techniques [28] . Specifically, in the case studies presented [28] , physical devices, e.g., inverter controllers, are compromised exploiting control logic modification techniques impacting power conversion, power factor, active/reactive injections, etc. Additionally, cyberattacks targeting communications -via time-delay attacks on the cyber domain -and the impact of intercepted, delayed, and/or modified control commands on the simulated power system models are also demonstrated. We refer to mission-critical system assets which can jeopardize grid operation if maliciously compromised by threat actors as crown jewels [41] . Crown jewels span the ICT infrastructures, such as the stakeholder-to-DER device communication channels [38] , physical-interfaces [36] , and the DER devices themselves. Notably, DER devices include PV inverters or smart inverters [32] , battery energy storage systems, EVs, wind turbines [35] , demand-side loads [42] , and DER controllers. Gaining access to any of the aforementioned crown jewels, it enables adversaries to manipulate DER power output (e.g., generated, stored, etc.), which can result in possible brownouts, false trips, feeder overloadings, voltage/frequency violations, damaged protection equipment or system instabilities [43] . In Table II , we present a summary of attack vectors targeting DERs and inherent cyber-threats based on related security research studies [4] , [43] , [44] . In this work, we distinguish between attacks targeting the DER communication protocols used for the control and coordination of DER assets, and the actual DER embedded devices and their underlying components, i.e., hardware, and software. Although the threat surface for these two categories might share similarities, it has also differences (e.g., attack access, exploitation tactics and techniques, etc.). Along with these differences, the interoperable nature of DER systems mandates comprehensive security mechanisms that treat the DER crown jewels jointly. Table III compiles common cyberattack definitions relevant to DER asset vulnerabilities. III. VULNERABILITIES, ATTACKS, IMPACTS, AND MITIGATIONS The proliferation of DERs could increase grid resilience to unexpected events (e.g., faults, attacks, etc.) through the autonomous operation of DER-enabled microgrids [47] , [48] . However, in order to control and monitor the operation of DERs, perpetual communication between utilities and aggregators is essential [49] . The utility-or aggregator-to-DER interconnection leverages application-specific communication protocols operating on embedded systems located at the DER-side. Although such communication protocol and embedded system synergies optimize DER performance, they also broaden the threat landscape. Below, we first discuss vulnerabilities, attacks, impacts, as well as mitigations related to DER communication protocols (III-A). Then, the equivalent investigation is conducted with emphasis on the DER devicelevel security profile (III-B). The following sections elucidates DER protocol-level security oversights and furnishes approaches to mitigate and overcome the impact of intrusions exploiting the communication plane. We examine prominent industrial control protocols systematically and demonstrate the DER cyber kill chain (5) indicating the steps that adversaries need to follow to compromise EPS operations. 1) DER Protocol Level Vulnerabilities: The most commonly used protocols for DER communication include the IEEE 1815-DNP3, Modbus, OpenADR, and IEEE 2030.5 [50] . However, most of these protocols did not originally support any overarching cybersecurity requirements [51] . More specifically, Modbus and DNP3, two widely used serial protocols in process automation systems, have several identified vulnerabilities [52] . For instance, the authors in [53] , provide an comprehensive attack taxonomy for DNP3 and discuss 28 different attack types. The presented attacks can be classified into four broad threat categories, including DNP3 data i) interruption, ii) interception, iii) modification, and iv) fabrication Eavesdropping Attacker "listens" to confidential in-transit data potentially stealing sensitive information. [45] , [46] Man-in-the-Middle (MitM) Adversary redirects communication packets through a compromised "middle" node (e.g., network switch, gateway, etc.) enabling monitoring and modification of such packets before they reach their destinations. [4], [31] , [46] Denial of Service (DoS) Target resources are overloaded (open ports are flooded with traffic), inhibiting its nominal operation. Targeted devices become "laggy", unable to timely issue responses to legitimate device requests. [38] Packet Replay Data transmissions between DER client applications and the DER devices are recorded, modified, and retransmitted by attackers at different time instances. [38] , [44] Supply-chain Adversary adds malware during either the component manufacturing, system integration, shipping, or installation stages. The malware can be weaponized remotely to perform unauthorised/unintended actions. [31] Brute forcing and fuzzying Adversary attempts to guess credentials, encryption keys, etc. or bring the system to an unexpected state. Once the above conditions are met, the adversary could attain unauthorized access to the system resources. [44] attacks ( Fig. 3 ). Interruption and interception attacks could delay control commands to industrial assets or acquire data in-transit. However, modification and fabrication attacks arise as the most threatening since they can send erroneous data affecting industrial processes, alter device configurations, and spoof master controllers, as shown in Fig. 4 . As a result, the attack impact ranges from the acquisition of network and device configuration data to the corruption of remote devices and acquiring control of DNP3 master units. Similarly, more than 700 vulnerabilities have been identified in the open source CERT Java-based implementation of OpenADR [54] . Some of those vulnerabilities could be remotely exploited, compromising sensitive exchanged data such as usernames, system properties, installation directories, etc. [55] . To enhance the security of DER communication, IEEE 1547-2020 interconnection and interoperability standard identifies the security requirements which need to be satisfied by both communicating parties [56] . Although compliance with IEEE 1547 can safeguard the exchanged data and control commands issued between DERs and aggregators, cyberattacks aiming to disrupt grid operations remain (e.g., DoS). Out of the aforementioned DER protocols, only IEEE 2030.5 was developed with stringent cryptography requirements [57] . The latest versions of DNP3 [58], Sunspec Modbus 700 series [59] , and OpenADR 2.0 conform with IEEE 1547-2020 and National Institute of Standards and Technology (NIST) requirements. As such, they can be seen as semantically identical from a security standpoint with IEEE 2030.5 [59] . Furthermore, transport layer security (TLS 1.2 or 1.3) is advised for all protocols to enhance wireless communications security between aggregators and DER edge devices [44] , [60] . Although there are secure communication protocols, the network communication infrastructure remains a prominent threat vector for adversaries. This can be attributed to the hesitation of industrial facilities to switch to newer and more secure communication protocols considering the potential economic or operational overheads. The plethora of legacy devices is also a limiting factor that restricts the modernization efforts of the communication fabric. The situation is further exacerbated, since according to the Electric Power Research Institute (EPRI), more than 75% of North American electric utilities use the DNP3 protocol for industrial control applications and supervisory control and data acquisition (SCADA) systems [61] . For instance, attacks targeting DNP3 communications could either aim to exploit vendor implementations of the protocol, protocol specifications, or vulnerabilities in the supporting communication infrastructure [53] . In addition to DNP3 protocol vulnerabilities, the user datagram protocol (UDP) vulnerabilities arise since in some systems, portions of DER modification requests are passed in plaintext [43] , which presents a critical control vulnerability to the DER system. Applying the latest protocol versions using TLS and cryptographically secure communication channels can potentially deter adversaries. However, the security of the power grid system is contingent upon each weakest link. Knowing that many already deployed DER devices support: insecure and outdated versions of the aforementioned communication protocols, limited computational capabilities prohibiting the implementation of sophisticated encryption algorithms or even updating their firmware (e.g., could be infeasible due to field operational constraints), urges for potent attack detection and mitigation mechanisms. Following, we discuss some of the eminent cyberattacks exploiting the pitfalls of protocol vulnerabilities. 2) DER Protocol Level Attacks: To identify which layer of the protocol stack is targeted by each attack, the Open Systems Interconnection (OSI) basic reference model is used [62] . The OSI model has seven major layers: application, presentation, session, transport, network, data link, and physical layer. In this paper, we focus on the security of commonly used industrial control protocols and specifically consider the data link, network, and transport layers of the OSI stack. The physical layers as well as the session, presentation, and application layers are not discussed since no security requirements are defined for the physical layer (bit transmission layer) while the aforementioned higher OSI layers can be application-specific or supported by other application protocols (e.g., secure file transfer protocol -FTP/SFTP, simple network management protocol -SNMP, telnet, etc.). Data link layer uses the Ethernet protocol which is vulnerable to media access control (MAC) spoofing attacks. The MAC address can be spoofed allowing Ethernet frames to be forwarded to adversaries [34] . In addition, MAC flooding attacks target the MAC address tables used by switches to store the information of legitimate devices, as well as the specific ports (of the switch) that each device is connected to [34] . On the network layer, the cybersecurity of DER device communication is specified by IEEE Std. 2030.5, which operates over UDP and transmission control protocol (TCP) with support for IPv4 and IPv6 protocols [44] . Many owners of DER devices (e.g., rooftop solar panels, EVs, BESS, etc.) have means for communication with their DER devices, which provide them with data such as measurement statistics, network communication analysis, firmware updates and more. The client-to-DER device communication utilizes the UDP protocol. Attacks targeting UDP's vulnerability such as packet replay attacks on the client-to-DER device communication have also been reported [43] . In more detail, during a successful packet replay attack, the plaintext requests are captured while being transmitted. The attacker can then send the captured packets and issue malicious commands to the DER, resulting in device malfunctioning. For IPv4/IPv6 protocols, potential attacks include but are not limited to network reconnaissance, packet replay, MitM, and DoS [38] . Typically, sophisticated MitM attacks on client applications and DER device communications have multiple steps. First, the adversary eavesdrops the DER-to-client communications and then performs address resolution protocol (ARP) poisoning and port stealing attacks [38] . ARP poisoning forces the MAC address of the adversary to be linked to the IP address of the target. This technique enables the interception of data in transit. Port stealing enables the interception and modification of data by the adversary before it is delivered to the destination [38] . On the transport layer, the predominant attack is synchronization (SYN) flooding. During this attack, the adversary sends continuous SYN requests to different ports of the target device using fake IP addresses [34] . The target device sends acknowledgement packets (SYN-ACK) to each requesting fake IP [34] . Since no consequent actions are provided by the fake IP client, this results in the target device's port to remain open until the connection times out and another fake SYN request is received. SYN flooding is a type of DoS attack limiting the availability of the target device. 3) DER Protocol Level Impacts: The MAC spoofing attack on the data link layer can result in adversaries gaining unauthorized access to the network by maliciously modifying the source IP address [34] . Another attack on this layer, MAC flooding, can target DER devices such as inverters, which may result in overuse of memory and potential bottlenecks in communications [34] . Adversarial impact could lead in loss of availability in communication with the DER device, including the inability to control DER power management parameters. MitM and packet replay attacks on the network layer of DER device communication leverage the commands received from client applications using UDP/IP transport protocols. Such interception is possible since security examinations have reported incidents where sensitive information involving DER generation data and control commands are exchanged in plaintext format [38] . Traffic analysis and in-transit packet inspection can be used to exfiltrate setpoint values and issue control commands. The underlying impact of a successful packet replay attack is demonstrated in [63] , where the replay attack doubles the magnitude oscillations of the DER's real output power. In microgrids, especially during autonomous operation or in weak grid setups, such disturbances could result in relay trippings, damaged equipment, and potentially load shedding events [64] - [66] . The impact of a protocol-based DoS attack, e.g., during SYN flooding, could diminish the availability of the target DER device. Reference values for real power, reactive power, and phase measurements are critical for the proper operation of inverters. If such information is not timely delivered, realtime reference values cannot be updated, and thus, the DER operation is indicated by firmware defined defaults [63] . Such distortions can result in under or over generation by the inverter, leading to uneconomic operation and even real and reactive power instabilities in the DER connected grid [67] . 4) DER Protocol Level Mitigations: Different mitigation strategies for protocol-level attacks have been reported in the literature [34] , [68] . To mitigate spoofing attacks on the data link layer, authentication-based access control is necessary. In the presence of authentication-based access control, the communication between the client and the device has to be first authenticated before the client is allowed to connect and exchange data and control commands. An alternative proposed mitigation approach considers the network switch configuration, i.e., white-listing a limited number of trusted MAC addresses, while discarding any requests received from unknown sources. Network switch best practises suggest the deployment of an authentication, authorization, and accounting (AAA) server, that manages network connections and certifies that the MAC addresses are added to the table only after the authentication process. On the network layer, the use of firewalls, one-way communication diodes, packet filters, circuit-level gateways, proxy servers, and two-way authentication can be utilized to prevent network reconnaissance, packet replay, MitM, and DoS attacks. The use of physical and logical network segmentation and perimeter security defenses can be used to prohibit access to critical parts of the system and prevent the lateral movement of threat actors between IT and ICS networks (if the prior is compromised) [69] . Demilitarization zones (DMZ) should also be enforced to aid in network segregation and serve as proxies, avoiding the security hazards that networkconnected devices could port to DER control functionalities. Furthermore, the implementation of cryptographic techniques, secure key distribution, and exchange schemes can help prevent MitM and replay attacks [70] , [71] . Additionally, DER applications which use TCP/IP are more resistant to packet replay attacks because such attacks use the unique session IDs that the DER device generates during the initial three-way TCP handshake (communication initialization) [38] . However, TCP/IP transport includes additional IP header information that DER applications can use to prevent packet replay attacks. Based on this unique IP header, the server is able to detect and drop duplicate packets, hence preventing packet replay attacks. On the transport layer, mitigation of SYN flooding attacks is achieved by cryptographic hashing and stack tweaking, which reduces the connection request timeout period and drops incomplete connections. Cryptographic hashing will determine the legitimacy of the connection by sending the SYN-ACK packet with a code derived from the client's IP address, port number, and a unique ID number. This dropping of incomplete connections in stack tweaking opens up the port for a legitimate connection. Additionally, the use of firewalls, intrusion detection and protection systems (IDS/IPS), and traceback and push-back services aims to limit the rate of traffic, therefore countering DoS attackers. In Fig. 5 , we present the DER cyber kill chain. In essence, we recapitulate protocol vulerabilities and attack entry points, as well as enumerate the potential impacts of attacks along with mitigations to overcome such adverse events. Different DER categories can be identified based on their principle of operation, e.g., generation, energy storage, hybrid, controllable loads, etc. As a result, DER device compromises can impact grid operations to varying degrees based on their category and system utilization. This section enumerates vulnerabilities, attacks, impacts, and mitigations on the DER device level, including the physical components encountered in such DERs (e.g., sensors, actuators, controllers, etc.) along with their inherent hardware, firmware, and software. 1) DER Device Level Vulnerabilities: Inverter-based resources are rapidly deployed in EPS on a commercial and residential scale. However, they remain vulnerable to cyberattacks that can modify or erase their default DER settings [72] , [73] . Rooftop PV inverter control, for instance, is regulated both on the local level (primary) as well as at a higher level, i.e., secondary control. The primary control system is responsible for matching the inverter-generated energy to the consumer power demand. Contrary to the local control system which operates on the consumer side, the secondary control system resides on the concentrator/aggregator and utility sides. The secondary control system orchestrates inverter operation on a larger scale, optimally dispatching power and meeting dynamic power demands economically. Typically, these control systems are operated remotely, using Internet-of-Things (IoT)based and third-party applications, which could expose such DER devices to cyberattacks. For example, in [38] , the authors demonstrate that by eavesdropping DER communications (performed over the Internet), passwords, user data, serial IDs and device names can be extracted using network traffic analysis software (e.g., Wireshark). Furtheremore, in some cases, sensitive information is exchanged in plaintext format, highlighting the importance of end-to-end data encryption and endpoint security hardening on the physical device itself. Similar security concerns exist for wind turbines too, which represent another DER type being rapidly integrated in the electric grid. In more detail, wind turbine control panels (WTCP) are used to control turbines and monitor their realtime operating conditions, e.g., their generation setpoints are dynamically controlled to meet the electricity demand. According to [74] , in some deployments, the only security practices employed against adversaries attempting to access the WTCPs are software-based credential authentication (e.g., passwords, identification number, PINs, etc.). Standalone credential authentication is not regarded secure, granted that it can be bypassed using brute forcing and fuzzing techniques. Additionally, phishing, spear-phising, vishing, etc., and other social engineering campaigns have also managed to exfiltrate sensitive authentication data from operators potentially jeopardizing the secure operation of wind-based DERs. The electrification of the transportation sector is a major thrust towards grid decarbonization. As a result, a precipitous growth has been observed in the numbers of EVs across the world. Among their advantages (e.g., greener form of transportation), EV batteries can be used as backup power supplies during unexpected and instant power demand. To support such ancillary backup services, as well as to charge their battery resources, EVs connect to the electric grid via charging stations. According to [75] , EV charging stations (EVCS) perform the following tasks. First, they authenticate the vehicles, and then they either charge them or connect them to the main grid where they can be utilized as adhoc energy storage. Authorization can be done through radio frequency identification (RFID) cards, Bluetooth, or Wi-Fi technologies. However, RFID systems have been proven to be insecure. According to [76] , RFIDs are vulnerable to malicious attacks such as eavesdropping and active interference. RFID readers and tags operate in noisy and inherently unstable environments, which decreases the security of the device and can consequently compromise the EVCS. Furthermore, authorization done using wireless networks (Wi-Fi or Bluetooth technologies) can be exploited by adversaries as well. Multiple design flaws, security weaknesses, and practical attack scenarios have been reported regarding Bluetooth technologies, enabling adversaries to pair to devices and impersonate their legitimate users [77] , [78] . Apart from the authorization and wireless network configuration security oversights, a plethora of threats targeting EVs is reported in [79] . The authors present in their security analysis the vulnerable components of EVs that could be exploited by adversaries (e.g., via remote and network-based attacks) compromising grid operation. Apart from the discussed vulnerabilities concerning generation-type DERs, critical vulnerabilities in DER controllable loads also exist. The IoT is a network of connected devices including smart appliances (e.g., smart thermostats, air-conditioning, heat pumps, EVCS points, etc.), enabling the exchange of information between devices and users leveraging wired and wireless connections [80] - [82] . These IoT-enabled devices are connected to the load-end of DERs and their operation is typically orchestrated remotely by their end users. According to [80] , [83] , a large number of IoT devices (using remote internet access mechanisms) still lack concrete security mechanisms and, as a result, can be vulnerable to cyberattacks. Researchers have demonstrated that attackers can manipulate IoT-connected devices in low-inertia EPS (e.g., relying on renewable generation) and other exogenous conditions to cause unsafe grid operation. That is, in [82] , [84] , the authors investigate the impact on grid stability of load altering attacks -if multiple IoT-connected high-wattage devices are compromised simultaneously -during the COVID-19 lockdown period. This adversarial behavior is enabled by the absence of overarching defense mechanisms, such as anti-viruses, and the sporadic provision of software/firmware updates and security patches which further weaken the device security posture. As a result, the vulnerabilities of such IoT-connected devices can be ported to the utility grid, given their interconnection to DERs. The authors in [85] report that another compelling reason undermining IoT -and DER-controllable load -security is that during the design cycles of such devices, function and lowering manufacturing costs were prioritized above firmware security. As a result, end-users are presented with impressive and feature-full devices furnishing multiple backdoors that adversaries can exploit; paving the way for malware developers [85] . Smart thermostats, for instance, represent a prime example of how the consequences of a compromised IoT device could propagate posing threats to the power grid. Smart thermostats can regulate the temperature of residential or commercial facilities by "cleverly" managing heat sources and air conditioners. Furthermore, thermostats can learn their users preferred patterns and adapt their operation accordingly [86] . The cybersecurity of such devices has been shown to be lacking since many are shipped from manufacturers using default configurations and predefined credentials [80] . Furthermore, the end-users of such devices might be unaware of the essential steps to configure their devices and secure them against cyberattacks. Consequently, such devices are left vulnerable to attacks which could simultaneously trigger on/off particular loads (e.g., heaters) deliberately affecting the instantaneous power demand of power grids leading to blackouts or brownouts [4] . Similarly to IoT-based systems which leverage ICTs to exchange information, recently the design of solar farms has also incorporated "smart" features. Essentially, in large solar deployments, ICTs have been used for remote and real-time management of the generated power for economic dispatch and demand-response schemes. Apart from remote and centralized control, storage solutions have also been used for the aggregation of historical and generation data, exposing solar farms to threats (e.g., single point-of-failure paragon). The remote control, communication, and data aggregation features of grid resources can be exploited as attack entry points. This was the case with the cyberattack targeting VESTAS offshore wind turbine manufacturer, which led to the ex-filtration of sensitive data and "forced VESTAS to shut down IT systems across multiple business units and locations to contain the issue" [87] . Although, according to the Danish wind manufacturer, customers were not affected by the event, the socio-economic and reputation blow to the company was acute. In residential solar PV deployments, communication technologies such as Bluetooth are mainly used regardless of the limited cybersecurity mechanisms, which can result in security breaches, compromising user privacy and escalating to grid abnormalities [42] . Aside from the attacks on IoT controllable loads and generation assets that stem from inherent implementation or architectural vulnerabilities, the possibility of supply chain based attacks should be accounted. Security oversight in manufacturing facilities can be exploited to construct supply chain attacks, in which adversaries are granted apriori control over thousands of DER-connected assets [88] . The possibility of such supply-chain compromises along with the catastrophic consequences of such events was demonstrated during the colonial pipeline incident in 2021 [17] . 2) DER Device Level Attacks: Attacks targeting the DER device level exploit implementation, architectural, and other security design oversights (e.g., communication, internal storage, remote update or control functionality, etc.) in order to maximize their impact and compromise power system operations. In the case of inverters, for example, after successfully gaining access to the DER assets, adversaries can launch cyberattacks including, i) DoS attacks compromising the inverter's availability, ii) data alteration attacks where the exchanged data between DERs and utilities are maliciously modified, and iii) command injection attacks where termination commands or malicious controls are forwarded to the inverters [30] , [89] . During DoS attacks, the communication bandwidth of the inverter can be flooded leading to device disruptions, i.e., the process control flow of the device is halted [38] . Inverter operation is dynamically regulated to enhance power generation efficiency and support ancillary services when requested by grid operators. However, adversaries could delay or prevent the transmission of critical data (e.g., sensor measurements, control commands, etc.) to certain DERs inhibiting their operation [38] . MitM attacks can also be leveraged to compromise grid inverters. In such scenarios, attackers can gain device-level information by eavesdropping on the data traffic between inverters and the utility grid. Attackers can access system information by decoding manufacturing message specification (MMS) packets [32] . MMS is used to transmit real-time data between connected devices in a network. Given that most inverter models use MMS to send and receive data, such attacks could potentially have a considerable impact on the grid stability. For instance, attackers could compromise the device operation by modifying the inverter configuration using undesirable parameters, e.g., tampering with the reactive power reference of inverter-based DERs [90] . Furthermore, brute force attacks can be leveraged to compromise DER assets. In [74] , researchers demonstrate that adversaries can brute force weak PIN sequences granting access to WTCPs. Similar to the aforementioned inverter command injection attack, adversaries can then send malicious commands to wind turbines, modifying setpoints or control objectives, causing unexpected operation with various grid impacts [91] . In many cases, DER assets are owned by end-users. In such scenarios, DERs can be connected to user networks exhibiting similar operation to common IoT devices. As such, they could be remotely operated and controlled by consumers or other third-party applications. IoT devices have been exploited on a massive scale in the past, as was the case with the Mirai botnet attack [80] . The Mirai malware, after its propagation to multiple vulnerable IoT devices, it grants adversaries full control over the compromised devices. The groups of compromised devices, i.e., botnets, can be exploited collectively causing distributed DoS (DDoS) attacks [92] , [93] . However, in the case of DERs, which have power generation and ancillary service capabilities (e.g., reactive power compensation), such attacks could severely affect grid stability. Apart from botnet attacks, other common IoT-sourced vulnerabilities could be abused, compromising DER operation. Attackers can perform replay attacks, where legitimate commands transmitted from DER asset owners can be reproduced. RFID authentication and Bluetooth or Zigbee communication packets can be eavesdropped and replayed, achieving unauthorized access to DER devices [94] , [95] . Additionally, the security of these IoTconnected DER devices is relied upon the user competence in safeguarding their assets. If the IoT network security is overlooked, adversaries could capture exchanged data, obtain session or encryption keys enabling them to access the devices, and issue commands that can render them unreachable (DoS) or instruct DERs to operate anomalously [95] . 3) DER Device Level Impacts: Adversaries, after having gained initial access to DER devices, can follow different approaches to deploy and/or implement their attacks [40] . If maximizing the immediate system-wide impact is their objective, overvoltage or undervoltage conditions, frequency fluctuations, false trippings, disconnections, and defensive islanding mechanisms could be targeted. Power systems have built-in mechanisms to automatically detect and isolate such high impact events to avert their potentially disastrous consequences. Different methodologies can also be utilized, physicsbased, data-driven, or a combination of the two, could be used to detect and overcome such conditions [32] , [96] , [97] . On the other hand, in the advanced persistence threat (APT) case, threat actors might prioritize system persistence, breach of privacy, and long-term system degradation instead of immediate impact, and opt for more sophisticated and stealthy attacks [98] . For instance, attackers could remain in control of the DER device while stealthily performing minute modifications to system parameters or coordinate attacks in ways that will not affect the net system behavior deceiving detection mechanisms [99] , [100] . Such stealthy attacks might cause unsafe, unstable, or uneconomic operation of IBRs. Adversaries could also exfiltrate sensitive user information (e.g., credentials, passwords, etc.), since DER devices might be connected in user-owned home networks. Attackers may also be learning the operational patterns of DERs, that is, aggregating enough system information to identify the temporal and spatial conditions which, if satisfied, can maximize the impact of attacks on the grid [99] , [101] . The rapid adoption of EVs (from 3 million in 2017 to 125 million by 2030 [102] ) makes them prominent targets for attackers aiming to gain access to EVs or EVCS. Malware can be deployed and propagated throughout the whole EV infrastructure, compromising the charge controllers, demandresponse schemes, charging limits, grid power quality, and crippling the power and transportation sectors [103] . Ac-cording to [29] , compromised EV supply equipment (EVSE) servers can prevent EVCS sessions by denying authentication, or reproducing incorrect information about charging station data (e.g., price, online station status, etc.). Furthermore, EVCS being high-wattage assets, if maliciously manipulated in addition to power-related consequences (e.g. increased load demand, power quality issues, etc.), can also inflict considerable financial losses on electric power utilities [104] . Similarly, sensitive user information (e.g., identity, location, payment information, etc.) could be leaked during potential attacks on the EV and charging infrastructures [105] . The absence of attack impact assessment methodologies for EV networks is highlighted by the authors in [106] . Their work attempts to identify potential attack and failure scenarios, while demonstrating the consequences of such events to the corresponding EV system security. Researchers have demonstrated that multiple paths exist to compromise the security of wind-integrated DER assets. In [74] , access to WTCP is granted by launching a brute force dictionary attack on the WTCP device. Similarly, in [91] , by compromising the network devices and wind process automation controllers, malicious requests can be issued to the turbines, preventing the nominal operation and potentially causing damage to critical electrical and mechanical components [107] . The impacts of wind turbine abnormal operation can lead to fires, explosions, jeopardize personnel assigned to resolve such issues, and the safety of the surrounding communities. Such impacts are highlighted by a plethora of high profile wind incidents reported in literature [108] - [111] . Although the aforementioned impacts have not been caused due to cyberattacks, the probability of exploiting wind turbine vulnerabilities remotely exists and research works have been focusing on the impacts that such attacks could have on grid reliability [112] , [113] . Malware, such as the Mirai and many of its derivatives, could be exploited to control the operation of IoT connected DERs leading to intermittent operation and DDoS attacks [114] . As a result, the botnet of the compromised DER devices, can be maliciously operated as a distributed load or generation. Grid instability can thus occur when DERs and other remotely controlled high-wattage devices (i.e., smart thermostats, EVs, EVSE, Heating, Ventilation, and Air Conditioning -HVACs, etc.) are simultaneously switched on or off severely affecting the electricity power demand [115] . In large scale demandside attack scenarios, grid operators will be forced to perform load-shedding to maintain the operation of critical loads [84] . A summary of potential vulnerabilities and the attacks impacts of demand-side compomises targeting DER devices and aggregators is depicted in Fig. 6 . Consumers might experience brownouts and service interruptions, while the impacts of loadaltering attacks on the local power supply will also affect demand-response schemes [116] . Apart from the grid impacts, the infected devices could also propagate malware (in a wormlike fashion) to the rest of the devices residing within the same network (e.g., switches, personal computers, mobile phones), thus, jeopardizing sensitive user information [117] . 4) DER Device Level Mitigations: To combat threats targeting DER devices, a multitude of mitigation strategies have been proposed. With respect to inverters, the authors in [43] suggest that an additional power electronic interface (energy buffer) should be developed and placed at different locations within the distribution grid (mainly at points where the device is connected to the grid). This energy buffer interface can help avoid unintentional islandings, which could be triggered due to the conflicting anti-islanding detection and low/high voltage ride-through functions that inverters support. The microarchitectural hardware components of inverter controllers have also been utilized for the detection of malicious events within the DER asset's process control loop [37] . In [48] , the inherent physical properties of DER-integrated grid systems are used to identify potential actuator or sensor modifications which could lead to abnormal system operation. Furthermore, a multitude of model-and data-driven anomaly detection methods have also been proposed to identify compromised DER assets [118] - [120] . Once intrusions have been efficiently detected, the compromised assets are isolated and the available grid resources are utilized to achieve resilience and maintain the power supply-demand balance equilibrium [121] - [124] . The prevention of adversaries from launching DoS attacks on EVSE can be achieved via the use of hardened operating systems [125] . Such systems can be leveraged to deploy and keep the EVSE with the up-to-date firmware. Furthermore, roll-back firmware update functionality is essential, enabling the use of previously working firmware, in cases where the updated firmware versions are proven unreliable or have been maliciously modified. Different methodologies have also been proposed for the mitigation of the harmonic interference of EV-related cyberattacks. For instance, the authors in [126] and [127] , propose pulse-width-modulation and a high-frequency resonance scheme, respectively, that can mitigate the power quality degradation introduced by EVs and bidirectional gridtied converters (e.g., battery storage). On the other hand, a power management framework leveraging renewable resources and the EV infrastructure itself is used in [128] , in order to alleviate power quality challenges encountered in unbalanced distribution networks. The importance of cyber insurance against cyberattacks on EVCS has also been highlighted by researchers. In [104] , the authors demonstrate that defense mechanisms and cyber insurance policies can effectively reduce the financial impacts of cyberattacks and curtail insurance premiums for the entities that manage EVCS. Towards mitigating brute force attacks targeting weak credentials used by WTCP, [125] recommends the usage of password management systems. Furthermore, monitoring user behavior (e.g., failed login attempts), the implementation of network segregation, and role-based access control rules are encouraged to restrict the adversarial access to DER wind turbine assets. In order to mitigate stealthy attackers aiming to gain access to wind turbines controllers exploiting their remote firmware update capabilities (e.g., over-the-air updates), the authors in [129] and [130] have proposed different methodologies to ensure that benign firmware versions are deployed on the devices. In [129] , a secure firmware update scheme is introduced, where devices leverage the blockchain to check for new firmware versions and validate their integrity before downloading and installing the firmware images to the target embedded device. On the other hand, the authors in [130] , leverage a hardware architecture to validate firmware authenticity. Cryptographic modules, in addition to the embedded device's physical characteristics, are utilized to guarantee the integrity and authenticity of firmware packages impinging malicious firmware deployment attacks. When viewing DERs from the IoT perspective, most of the security implications and attack mitigation strategies applicable for IoT end-devices could be exercised. In [131] , the authors suggest the use of a personal security application (PSA) as a countermeasure for IoT-related attacks. PSA resembles a combination of security features, such as access control mechanisms, malware detection, network traffic, and resource utilization monitoring, etc., to strengthen the security posture of IoT devices and networks. Blockchain technology has also been mobilized to safeguard the security of IoT networks, singling out malicious nodes from benign ones [132] . For example, a blockchain detection methodology is presented in [114] to protect IoT nodes from the Mirai botnet. In [80] , a thorough review of IoT attacks and their corresponding mitigations are presented. A plethora of design best practices, mitigation techniques, and security policies are enumerated, viewed from the device, infrastructure, communications, and services standpoint. The authors also discuss open challenges regarding the security of future IoT systems, which closely relate to the obstacles that DER infrastructure will have to overcome (e.g., vendor locking, computationally limited resources, cost, data security, etc.). IV. CONCLUDING REMARKS AND DISCUSSION Improving EPS cybersecurity and resilience to adverse events is of critical importance. DERs are expected to contribute toward this effort. However, the alarming number and sophistication of cyberattacks targeting energy systems emphatically indicates that multifaceted security approaches should be considered. In more detail, detection, protection and mitigation schemes should factor in the inherent vulnerabilities encountered on the DER cyber and physical stacks. Security analyses should also contemplate on how DERs contribute to the power grid operation, given the potential risks and systemwide impacts of cyberattacks. This work explores the cybersecurity posture of DERs as an essential building block for future resilient EPS architectures. We investigate the cybersecurity threats that arise and present an overview of attacks targeting DER assets. The study examines DER vulnerabilities from the protocol and devicelevel and presents a consolidated review of attacks and their corresponding impact on the operation of DER. Mitigation methodologies and design best practices are also discussed to thwart adversaries and safeguard DER systems (Table IV) . Even though the proposed strategies could effectively reduce the DER threat surface, they still cannot be considered as "silver bullet solutions" which can address every application. This fact is partly attributed to the DER distributed mode of operation, which can be utility-, aggregator-, or prosumerowned. Especially for the later case, user negligence in the security configuration of their DER assets, could give rise to compromises. However, the risk and magnitude of such disturbances relies on how many DERs could simultaneously be attacked. Security conformance standards and policiessuch as IEEE 1547-2020 [56] and DNP3 [58] -should be created and enforced to ensure the innocuous DER operations even in untrusted environments (e.g., user-owned assets). Security challenges will still exist, regardless of the preventive and preemptive methodologies that we propose and the security of future DER devices that is expected to improve (both in the device and protocol levels). Developing universal risk management schemes can be a perplexing or infeasible task due to the distributed, ad-hoc (e.g., EVs, battery storage) and stochastic (e.g., solar inverters) nature of DERs. However, comprehensive system modeling using digital twin systems and data-driven approaches can be leveraged to forecast grid behavior and predict cyberattack impacts. Additionally, risk assessment and cyber-physical risk metrics can be developed to evaluate and prioritize mitigation decisions. High-fidelity information, derived from system models (i.e., digital twins), can assist risk-metric estimations using system-specific DER information, which in turn can be utilized when designing cyberattack response strategies and self-healing schemes. The influx of DER devices and their projected numbers underscore the need for comprehensive security practices. To harness DER advantages and withstand their underlying security impediments, the combined knowledge of security engineers, the industry, and the academic community is essential. User vigilance is also crucial to impede malicious behavior attempting to achieve foothold on user-owned DERs and even post-compromise to restrict attack propagation. Security Attacks Reference Network connection auditing using authentication, authorization, and accounting servers, role-based access control, authentication-based MAC address white-listing, unused port hardening MAC Spoofing, MAC Flooding, DoS, MitM, SYN flooding [34] , [38] IP header (Sequence number) inclusion in TCP, cryptographically enhanced address resolution protocols (ARP), secure key distribution and exchange schemes Packet Replay, DoS, MitM, SYN flooding [43] , [38] Firewalls, intrusion detection/prevention systems (ID/IPS), traceback and push-back services, cryptographic hashing and stack tweaking Mac Flooding, DoS, MitM, SYN flooding [43] , [44] , [34] Password management systems, access restriction after multiple failed log-in attempts, hardened operating system kernels, roll-back firmware updates Brute force attacks, DoS, Packet Replay, Eavesdropping [125] Personal security and privacy practises (e.g., security updates, password managers, encryption, ephemeral keys, etc.) Packet Replay, Eavesdropping [131] standardization and policy-making procedures can strengthen the cybersecurity posture of DERs and prevent vulnerabilities from materializing into treats and attacks. However, if the discussed practices fail to prevent or detect DER attacks, risk metrics, detailed system modeling, and mitigation plans can orchestrate available resources to inhibit or overcome undesirable grid conditions, thus enhancing EPS resilience. Grid Modernization Distributed energy resources: Connection modeling and reliability considerations A cyber attack resilient control for distributed energy resources Blackiot: Iot botnet of high wattage devices can disrupt the power grid Global Capacity of Distributed Energy Resources Is Expected to Reach Nearly 530 GW in 2026 2021 Outlook: The DER boom continues, driving a 'reimagining' of the distribution system Impact on electricity consumption and market pricing of energy and ancillary services during pandemic of covid-19 in italy Classifying resilience approaches for protecting smart grids against cyber threats The Timeline and Events of the February 2021 Texas Electric Grid Blackouts CVE-2018-0296 Detail Electric Emergency and Disturbance Report -Calendar Year 2019 Risks posed by firewall firmware vulnerabilities Supply Chain Threats against Integrated Circuits FireEye Shares Details of Recent Cyber Attack, Actions to Protect Community What You Need to Know About the SolarWinds Supply-Chain Attack SolarWinds and Beyond: Improving the Cybersecurity of Software Supply Chains Colonial Pipeline Paid Roughly $5 Million in Ransom to Hackers Florida Water Plant Hackers Exploited Old Software And Poor Password Habits Cyberattacks Cost Hospitals Millions During Covid-19 Healthcare cyber-attacks and the COVID-19 pandemic: an urgent threat to global health Distributed Energy Resource Cybersecurity Framework (DERCF) Renewable Energy & Distributed Systems Integration (RDSI) Ieee standard for interconnection and interoperability of distributed energy resources with associated electric power systems interfaces SUNSPEC MODBUS FOR IEEE 1547 Systems interface between customer energy management system and the power management system -Part 10-1: Open automated demand response IEEE standard for smart energy profile application protocol Cyber-physical energy systems security: Threat modeling, risk assessment, resources, metrics, and case studies Public plug-in electric vehicles+ grid data: Is a new cyberattack vector viable? Investigating cyber-physical attacks against iec 61850 photovoltaic inverter installations Recommended functionalities for improving cybersecurity of distributed energy resources Cyber security risk assessment of solar pv units with reactive power capability Secure and efficient vehicle-to-grid energy trading in cyber physical systems: Integration of blockchain and edge computing A survey of protocol-level challenges and solutions for distributed energy resource cyber-physical security Cyberattack to cyber-physical model of wind farm scada Annual Conference of the IEEE Industrial Electronics Society Exploring emerging cybersecurity risks from network-connected der devices Hardware-assisted detection of firmware attacks in inverter-based cyberphysical microgrids Cyber security assessment of distributed energy resources Industrial Cybersecurity: Efficiently secure critical infrastructure systems ATT&CK for Industrial Control Systems Techniques Crown Jewels Analysis Assessing cyber-physical risks of iot-based energy devices in grid operations Cybersecurity for distributed energy resources and smart inverters Cyber security primer for der vendors, aggregators, and grid operators Cyber security requirements and recommendations for CSI RD&D solicitation for distributed energy resource communications Cybersecurity assessments on emulated der communication networks The Value of "DER" to "D": The Role of Distributed Energy Resources in Supporting Local Electric Distribution System Reliability Detection of malicious attacks in autonomous cyber-physical inverter-based microgrids DER communication Roadmap for photovoltaic cyber security Recommendations for Trust and Encryption in DER Interoperability Standards Taxonomy of attacks on industrial control protocols A taxonomy of attacks on the dnp3 protocol The research on vulnerability analysis in openadr for smart grid CVE-2010-3860 IEEE 1547a-2020 -IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces -Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III Ieee approved draft standard for smart energy profile application protocol SunSpec Modbus Protocol An event buffer flooding attack in dnp3 controlled scada systems Osi reference model-the iso model of architecture for open systems interconnection A cyber attack resilient control for distributed energy resources On stability of voltage source inverters in weak grids On the stability of power electronics-dominated systems: Challenges and potential solutions Hall spoofing: A Non-Invasive DoS attack on Grid-Tied solar inverter Trustworthy cyberphysical energy systems: Timedelay attacks in a real-time co-simulation environment Special session: Harness the power of ders for secure communications in electric energy systems Guide to Industrial Control Systems (ICS) Security Secure group communication schemes for dynamic heterogeneous distributed computing Derauth: a battery-based authentication scheme for distributed energy resources Market analysis and forecast from Cybersecurity risk assessment for california's smart inverter functions Cyberattack to cyber-physical model of wind farm scada Cyber-physical system security of vehicle charging stations Classification of rfid attacks Two practical man-in-the-middle attacks on bluetooth secure simple pairing and countermeasures Security weaknesses in bluetooth Smart electric vehicle charging: Security analysis Consumer, commercial and industrial iot (in) security: attack taxonomy and case studies Securing iot devices and securelyconnecting the dots using rest api and middleware Load-altering attacks against power grids under covid-19 low-inertia conditions Anatomy of threats to the internet of things On the feasibility of load-changing attacks in power systems during the covid-19 pandemic 10 years of iot malware: A feature-based taxonomy Exploiting known vulnerabilities of a smart thermostat Vestas data 'compromised' by cyber attack Electric Grid Cybersecurity A review of cyber-physical security for photovoltaic systems Reactive Power Requirements for Non-Synchronous Generation Breaking wind: Adventures in hacking wind farm control networks Mitigating mirai malware spreading in iot environment Mirai source code Wireless security threats: Eavesdropping and detecting of active rfids and remote controls in the wild Attacks and defenses in short-range wireless technologies for iot Security assessment and impact analysis of cyberattacks in integrated t&d power systems Resilient cyber-physical energy systems using prior information based on gaussian process Advanced Persistent Threat Compromise of Government Agencies, Critical Infrastructure, and Private Sector Organizations Stealthy rootkit attacks on cyber-physical microgrids: Poster On detection of false data in cooperative dc microgrids-a discordant element approach Behind closed doors: Process-level rootkit attacks in cyber-physical microgrid systems Global ev outlook 2018: Towards cross-modal electrification Potential cybersecurity issues of fast charging stations with quantitative severity analysis Cyber insurance against cyberattacks on electric vehicle charging stations A detailed security assessment of the ev charging ecosystem Vulnerability analysis and risk assessment of ev charging system under cyber-physical threats Wind farm security: attack surface, targets, scenarios and mitigation Wind Power News: Accidents 5 High Profile Wind Turbine Fires New failure for flagship GE wind turbine as Cypress blade breaks in Germany Huge Vestas Wind Turbine Collapses in Northern Sweden in Rare Accident Cyber intrusion of wind farm scada system and its impact analysis Power system reliability assessment incorporating cyber attacks against wind farm energy management systems Protecting iots from mirai botnet attacks using blockchains Not everything is dark and gloomy: Power grid protections against {IoT} demand attacks Demand side load management for big industrial energy users under blockchain-based peer-to-peer electricity market Iot goes nuclear: Creating a zigbee chain reaction Active synchronous detection of deception attacks in microgrid control systems Cybersecurity analytics using smart inverters in power distribution system: Proactive intrusion detection and corrective control framework Detection and identification of cyber and physical attacks on distribution power grids with pvs: An online high-dimensional datadriven approach Effective utilization of available pev battery capacity for mitigation of solar pv impact and grid support with integrated v2g functionality Synchrony in networked microgrids under attacks Resilient and cybersecure distributed control of inverter-based islanded microgrids Resilient synchronization strategy for ac microgrids under cyber attacks Recommended functionalities for improving cybersecurity of distributed energy resources Pulse-width-modulation-based electromagnetic interference mitigation of bidirectional grid-connected converters for electric vehicles High-frequency resonance mitigation for plug-in hybrid electric vehicles' integration with a wide range of grid conditions Management of power quality issues in low voltage networks using electric vehicles: Experimental validation Blockchain-based secure firmware update for embedded devices in an internet of things environment A hardware-based framework for secure firmware updates on embedded systems Mitigating iot security threats with a trusted network element Blockchain and autonomous vehicles: Recent advances and future directions