key: cord-0556496-g9vvaknx authors: Kabir, Mohammad Ridwan; Ehsan, Mohaimin; Mahmud, Hasan; Systems, Md. Kamrul Hasan; Lab, Software; Science, Department of Computer; Engineering,; Technology, Islamic University of; Gazipur,; Bangladesh., title: Renovo: A Sensor-Based Therapeutic System for Brachial Monoplegia date: 2021-09-08 journal: nan DOI: nan sha: fc6d176b1a1a70cc74a0ec5ea079570243e458b9 doc_id: 556496 cord_uid: g9vvaknx $Introduction:$ Patients with Brachial Monoplegia, paralysis of the upper limb following various neurological disorders, require therapeutic interventions with proper assessment for rehabilitation. State-of-the-art assessment protocols, the majority of which are qualitative, often cause biased assessment. Very few therapeutic systems aim to assist the physiotherapists in this regard. $Methods:$ We designed a sensor-based therapeutic system for assisting the physiotherapists with real-time visualization of Performance Metrics and a reliable quantitative assessment. 5 healthy subjects (Mean=24.4$pm$2.4 years, 80% Male), 16 patients with Brachial Monoplegia (Mean=39.56$pm$16.4 years, 76.92% Male), and 5 physiotherapists volunteered with informed consent. Each patient was evaluated by both the system and the physiotherapists in 3 sessions. $Results:$ Insignificant difference between the mean (t(15)=1.39, p=.184) and the variance (F(1, 15)=1.05, p=.460) of system evaluation (Mean=6.19, 95% CI, [4.52, 7.86]) and that of the physiotherapists (Mean=6.38, 95% CI, [4.75, 8.01]) having a strong, positive correlation, r=.9885 was observed. The system showed good reliability from the Cronbach's Alpha test, with $alpha$=.8499. $Conclusions:$ To ensure effective rehabilitation, proper assessment is obligatory. Sensor-based measurement of performance metrics ensures reliability, reducing the chances of human error. Real-time visualization informs about patient's progress. Automated quantitative assessment reduces the possibility of bias, allowing optimization of rehabilitation scheme. Hemiplegia is a neurological condition that causes impairments on one side of the body. This occurs mostly due to stroke, spinal-cord injury, brain tumors and infections. Brachial Monoplegia (BM) is a sub-category of Hemiplegia that causes impairments in any particular upper limb of the human body. About half of the stroke survivors are left with permanent impairments [1, 2] . Patients with these impairments require appropriate therapeutic interventions for their rehabilitation. The aim of rehabilitation is to re-acclimate patients to the lost motor capabilities of their upper limb. However, it is difficult to determine the proper intervention for a particular impairment [3, 4] . There are two reasons behind this. First, with gradual recovery, the nature of impairment changes and may require customized rehabilitation approach [5, 6] . Second, there can be multiple impairments simultaneously [7] . Proper assessment and feedback on patients' progress is obligatory for ensuring an effective intervention. Physiotherapists have adopted many state-of-the-art assessment methodologies [8] [9] [10] , the majority of which are qualitative. One of the drawbacks of qualitative assessment is that it depends on the knowledge and experience of the physiotherapists. Very few methods [11, 12] provide a quantitative scale of assessment. For example, the popular Fugl Meyer Assessment (FMA) [11] scale provides three levels of scoring (0-only few degrees, 1-decreased, 2-normal) for evaluating patients' progress. Although quantitative, the assessment is completely dependent on how the physiotherapists interpret patients' muscle spasticity. Therefore, there is a possibility of biased assessment of patients' progress. Studies [13, 14] have shown quantitative assessment ensures a more reliable evaluation than the qualitative counterpart. In practice, physiotherapists evaluate patients with BM based on their performance in Goal-oriented Exercises (GoEs In the conventional mode of therapy, physiotherapists cannot visualize the key PMs of any intervention in real-time. They measure RoM manually with the help of a goniometer [15, 16] while patients hold their arms steady either voluntarily or with assistance from the physiotherapists. This makes recording RoM difficult for them and increases the probability of erroneous measurements. Keeping track of min-max angular displacement between sessions manually is also a tedious task for them. Physiotherapists manually count the repetitions of a particular therapy with no track of session time. They cannot fully ensure an unbiased evaluation of patients' performance. Furthermore, there is a lack of an automated patient management system. Rehabilitation in this manner is both inefficient and difficult for the physiotherapists. There are potential factors that may lead to inaccurate measurement of PMs. Some of these are but not limited to -1) Inability of the patients with BM to keep their arms steady until RoM is measured. 2) Need for assistance from another physiotherapist while taking measurements. 3) Lastly, the unavoidable human error. This inaccuracy may give a false interpretation of patients' progress. Apart from these issues, the patients may also be faced with health issues such as unwanted joint pain, increased muscle spasticity, numbness and many more. Over the years, researchers have developed numerous Assistive Technologies (ATs) for improving the quality of rehabilitation for patients with BM. Some of these include VR-based rehabilitation games [17] [18] [19] [20] [21] , kinematic analysis of upper limb motion using wearable Inertial Measurement Units (IMUs) [22, 23] , robotic exoskeleton for quantifying motor functionality in object reaching and manipulating tasks [24] [25] [26] , robot-assisted therapeutic intervention systems [27] [28] [29] [30] , and Functional Electrical Stimulation (FES) [31] . Researchers have also developed new standards for quantifying upper limb impairment based on kinematic analysis of upper limb motion using Microsoft Kinect [32] in different GoEs. However, few ATs such as the Automated Rehabilitation System (ARS) [33] have been developed that will not only assist physiotherapists with unbiased patient evaluation but also improve the quality and effectiveness of rehabilitation. In ARS, the authors have focused on the rehabilitation of 5 distinct movements of lower extremity after hip-knee replacement surgery. Using wireless IMUs, they have visualized the real-time motion of patients' lower extremity with a 3D model applying forward kinematics [34] [35] [36] . The system provides guidelines to the patient for a certain therapy both visually and theoretically. It also provides visualization of the key PMs and an automated quantitative assessment of the patients. Therefore, to assist physiotherapists in the rehabilitation of BM, there is a scope of developing a therapeutic system for real-time visualization of therapeutic interventions and quantification of the key PMs concomitant with an automated arXiv preprint quantitative assessment of patients' progress. Some of the major challenges of developing such a system are to ensure its usability and acceptability [37] along with the reliability of the system-generated assessment scores. With regard to the research scope and challenges, we have developed Renovo, a wearable sensor-based therapeutic system for BM following HCI paradigms. In our study, we have featured 16 basic motions of both left and right upper limbs such as, Wrist Flexion-Extension, Radial-Ulnar Deviation, Forearm Pronation-Supination, Elbow Flexion, Shoulder Flexion-Extension, Adduction (Horizontal), Abduction (Horizontal and Vertical), and External-Internal Rotation (Horizontal and Vertical). Finger joint movements are out of the scope of this study and will be considered in a future analysis. We have explored the alternative approach (Fig. 1) to the rehabilitation of patients with BM, where, rather than initiating rehabilitation with GoEs, the patients were first acclimatized to their upper limb motor functionalities through basic arm movements. It is to be noted that the system is not capable of deciding on patients' fitness for GoEs. Rather, based on the system generated scores, the physiotherapists decide whether a patient should be prescribed with GoEs. This research was conducted following the STROBE [38] checklist. Renovo is an AT for assisting physiotherapists with real-time visualization and quantitative evaluation of patients in the rehabilitation of BM. It consists of a wearable device and a processing software. The wearable device contains two IMUs for real-time motion tracking, one on the upper arm (IMU 1 ) and the other on the forearm (IMU 2 ). The User Interface (UI) of the processing software ( Fig. 2 ) facilitates real-time 3D visualization of arm motion along with the key PMs. It also features patient management, therapy-session management, and therapy-data storage. Physiotherapists can enrol a new patient or administer therapy to an existing patient, where each patient is assigned a unique system-generated ID. In a particular session, physiotherapists can select only one intervention from a list of therapies provided in the UI. Our system also allows them to choose either Passive or Active mode of intervention for either left or right upper limb. In the Passive mode, they instruct and train the patients in a particular therapy. On the other hand, in the Active mode, the patients perform voluntarily under observation of the physiotherapists. The UI also provides static illustration on how a particular therapy needs to be performed for a particular limb, total number of sessions conducted so far, patient details along with that of the current therapy. There is an adjustable session timer with a maximum session duration of 30 minutes. A particular session starts after a 10 second countdown period upon selecting the "Start" button. This acts as a psychological preparation period for both the physiotherapists and the patients. A session can end in two ways, either voluntarily by selecting the "Stop" button or with the expiration of the session timer. At the end of every session, the physiotherapists are given the option to save or discard the corresponding motion data for further reference. In this way, recording of erroneous data can be averted. arXiv preprint The sensor data are processed on the host PC using the following steps ( Fig. 3 ) for real-time visualization: 1) Prior to starting a session, the patients have to align their arm with the base posture of the corresponding therapy and hold for 8-10 seconds to allow for device calibration. 2) Raw motion data from the IMUs are then wirelessly transmitted to the host PC for further processing upon device connection. 3) After a session has been started, an orientation filter [39, 40] is applied on this data for generating 3D orientation angles (yaw, pitch and roll). 4) These angles are then processed further for generating joint coordinates of upper limb for 3D visualization applying forward kinematics [34] [35] [36] and Denavit-Hartenberg convention [41, 42] . 5) The key PMs of a patient during therapy are also generated from these angles. 6) All the processed information is then visualized in real-time in the system UI. The Real-time data processing favours seamless visualization of relevant information. Furthermore, wireless data transmission favours system portability and the patient is not required to be in closer proximity to the host PC. arXiv preprint Figure 3 : Workflow diagram of the real-time visualization of relevant information using Renovo. 1) Equip patients with the wearable device followed by device calibration, 2) Transmit raw motion data wirelessly to the host PC, 3) Generate yaw, pitch, and roll angles applying an orientation filter on this data, 4) Generate the coordinates of 3D motion of the arm applying Forward Kinematics (FK) and Denavit-Hartenberg convention, 5) Generate performance metrics from the 3D orientation angles, 6) Visualize the information real-time on the system User Interface (UI). At the beginning of any therapeutic intervention, the participants were equipped with the wearable device ( Fig.3-Step 1) . Before any patients were recruited, motion data from the healthy subjects were collected for all the motions featured in this study. Their data were later used as a reference for generating patient assessment scores through comparative analysis. In the case of the patients, selective motions were administered at the discretion of the physiotherapists. They advised on administering the rest gradually depending on the patients' progress. For a particular motion, the physiotherapists first guided them in the Passive mode of intervention of Renovo. Subsequently, the patients performed the same in the Active mode and their motion data were collected. For any particular intervention, all the participants participated in at least 3 sessions. Duration of each session with the patients was at the discretion of the physiotherapists. After each session. the participants were allowed to rest for a while to reduce the possibility of any fatigue or injury. The patients were simultaneously evaluated by the physiotherapists using the quantitative portion of the FMA scale apart from the system assessment. During therapy, the different motions of the upper limb are administered in a periodic fashion. In order to quantify the quality of these motions, feature vectors need to be derived from the corresponding motion data. These vectors summarize the statistical measures of the data. However, due to the periodic nature of these motions, different wave-related measures can also be derived from the data. In the literature, these feature vectors have been generated using measures that are either only statistical [23, 43] or only wave-related [33] or both [18] . The following steps (Fig. 4a) were followed for generating patient assessment scores in any particular therapy: 1) Patient PMVs for each session were vector normalized. 2) PMVs of all sessions of all the healthy subjects were combined, their metricwise mean was calculated followed by vector normalization to form a corresponding Reference PMV (RPMV). 3) For each session, the Euclidean Distance (ED) between the patient's PMV and the corresponding RPMV was then calculated. This distance is a measure of a patient's motor capability compared to that of a healthy person in that session for that therapy. However, it provides no information on the patient's progress in subsequent sessions. 4) Therefore, for all possible pairs of subsequent Sessions, we stored the difference between their EDs (SEDs) in a Progress Outcome Matrix (POM). It is a lower triangular matrix with dimensions equal to the total number of therapy sessions. For any element in POM with value less than or equal to or greater than zero, the corresponding Progress Outcome (PO) was defined as negative or neutral or positive, respectively. Similar to the FMA scale, these outcomes were then mapped to three numeric values (0-negative, 1-neutral, and 2-positive) each having a unique definition and interpretation (Fig. 4b) . 5) The Probabilities (P) of these outcomes were then calculated from the corresponding counts of negative (n g ), neutral (n e ), and positive (n p ) outcomes from the N elements of POM (Eq. 2). 6) Finally, the assessment score was generated by calculating the corresponding expected value of progress in that therapy (Eq. 3). arXiv preprint A key point to be noted here is that the assessment score is the expected value of PO. As a result, the PO of a session is quantitatively related to the patient's performance in a preceding session. Therefore, this score is cumulative and represents overall progress. Thus, in this regard, it is imperative to conduct at least 2 sessions for generating patient assessment scores using our proposed method. Furthermore, the maximum score of any session in our assessment protocol can be 2. Hence, the maximum cumulative score that a patient can obtain using our assessment method is twice the number of therapies administered. To ensure reliability of the assessment scores by the system, it is necessary to verify that their mean and variance do not differ significantly from that by the physiotherapists. To test for any significant difference in the mean and variance of the scores, we conducted paired two-tailed t-test for means and F-test, respectively. A significance level of α=.05 was considered for all the above tests. Furthermore, Pearson's correlation test was also conducted on these scores. We collected feedback from both the physiotherapists and the patients using the System Usability Evaluation Form (SUEF) (Appendix -A) and the Patient Consent and Feedback Form (PCFF) (Appendix -B) , respectively. The questionnaires were designed with elements combined from standard sets such as the USEQ (User Satisfaction Evaluation Questionnaire) [44] and QUIS (Questionnaire for User Interface Satisfaction) [45] and elements from feedback forms used in different studies [46, 47] . Based on these feedbacks, we conducted the Cronbach's Alpha (α) (CA) test [48] for quantifying system reliability. In this test, systems with alpha value >.80 is considered to have good reliability. The patient assessment scores by the system and average of the same by the physiotherapists after 3 sessions are summarized in Table-2a and Table- 2b, respectively. The therapies that were not administered are shown by a '−'. arXiv preprint Shoulder Abduction --0.6 2 1.8 - Difference between the mean of system evaluation (Mean=6.19, 95% CI, [4.52, 7.86] ) and that of the physiotherapists (Mean=6.38, 95% CI, [4.75, 8 .01]) was statistically insignificant, t(15)=1.39, p=.184, α=.05. Their variances did not differ significantly as well, F(1, 15)=1.05, p=.460, α=.05. We also observed a strong, positive correlation between the two assessments, r=.9885. The summary of the results can be visualized from a scatterplot (Fig. 5a) and a boxplot (Fig. 5b) of these scores. arXiv preprint From the summary of feedbacks of the patients and the physiotherapists (Fig. 6 ) according to the PCFF and SUEF forms, respectively, it was observed that about 43.75% of the patients did not feel the need for any assistance from the physiotherapists for rehabilitation using Renovo. About 68.75% of them were satisfied with our proposed method of interventions and 93.75% felt that the therapy was effective. All the patients found the system to be informative and they were able to visualize their performance with our system. The physiotherapists have verified that the device was harmless and do not have any long and short-term side effects. They have agreed upon the feasibility of our approach in motivating patients with BM towards rehabilitation. They also felt that the real-time visualization and automated patient assessment made it easier for them to conduct therapeutic sessions. Furthermore, the physiotherapists were convinced that, the system will allow them to have follow-up sessions with patients and guide them through optimized rehabilitation schemes. Considering both feedbacks, an average alpha value of α ̅=.8499 was found from the CA test which is a measure of good system reliability [48] . Results of this test on system reliability from both the physiotherapists' and the patients' perspectives are summarized in Table- 3. arXiv preprint Successful rehabilitation of BM depends on effective therapy and patient cooperation. Effectiveness can be ensured with accurate, real-time measurement of PMs and unbiased patient evaluation. Furthermore, feedback on the patients' progress will motivate them towards regular therapy. We have demonstrated the feasibility and impact of a sensor-based AT, Renovo, for assisting physiotherapists in the rehabilitation of BM. Compared to the conventional mode of therapy, with this system, they can visualize key PMs efficiently in real-time with lesser human error without causing any injury to the patients. They can also keep a track record of the patients' progress using the patient management feature. We have developed a quantitative assessment protocol for ensuring unbiased patients evaluation. We have shown this system-generated assessment to be statistically reliable. We have developed Renovo by conducting recurring requirement analysis sessions with the physiotherapists. Their primary requirement was that any AT targeted towards the rehabilitation domain should not be unsupervised. In other words, the physiotherapists should be aware of patients' progress so that proper therapies can be prescribed. The proposed system does not possess the ability to make any decision regarding patients' fitness for GoEs. Rather, the system generated scores serve as a reliable metric for the physiotherapists to make this decision which meets their primary requirement. The physiotherapists had also mentioned that the patients should not feel that they no longer need guidance from the physiotherapists for their arXiv preprint rehabilitation. From our analysis of the patients' feedback we have seen that this requirement has also been met by a very reasonable margin. There are few limitations of Renovo -1) All the therapies need to be started from a corresponding base arm posture. If this posture is not maintained during device calibration, the system will give erroneous results. This is due to the way we have designed the 3D model of upper limb considering only two IMUs. However, if more IMUs were incorporated, this could be overcome at the cost of a complex wearable setup and device usability. Due to this limitation, we could explore interventions in sitting position only. 2) During the device calibration period, patients require assistance from the physiotherapists for holding their upper limb in the appropriate position which might be uncomfortable to some. We did not implement any tele-rehabilitation feature in this study. Therapies related to finger movements were not explored as well. However, we intend to explore these in a future analysis of our work. We also intend to overcome the limitations of the proposed system and come up with a more versatile solution. To conclude, real-time measurement and visualization of PMs make conducting therapy sessions easier for the physiotherapists. Automated quantitative evaluation minimizes the chance of bias in patient's progress assessment and helps physiotherapists in customizing rehabilitation schemes. Allowing patients to visualize their performance and providing regular feedback on their progress can motivate them towards rehabilitation. The authors declare no conflict of interests that directly or indirectly affects the outcome of this study. All of them have approved this version of the manuscript for submission. ⃝ I felt hopeful about my progress. ⃝ I had little confidence in myself. ⃝ I was pretty confident in myself. ⃝ I was disappointed in myself. ⃝ I was blind about my performance. ⃝ I was well aware of my performance. ⃝ Therapy sessions were monotonous. ⃝ Therapy sessions were interesting. C. Answer in True or False. The long-term outcome of arm function after stroke: results of a follow-up study. Disability and rehabilitation Influence of task-oriented training content on skilled arm-hand performance in stroke: a systematic review. arXiv preprint Neurorehabilitation and neural repair Rehabilitation of motor function after stroke: a multiple systematic review focused on techniques to stimulate upper extremity recovery. Frontiers in human neuroscience The intersection between ocular and manual motor control: eye-hand coordination in acquired brain injury. Frontiers in neurology Evolving stroke and the ischemic penumbra The evolving nature of neuropathic pain: individualizing treatment Motor recovery following capsular stroke: role of descending pathways from multiple motor areas The Rivermead mobility index: a further development of the Rivermead motor assessment. International disability studies Investigation of a new motor assessment scale for stroke patients. Physical therapy Inter-rater reliability and validity of the action research arm test in stroke patients. Age and ageing The Fugl-Meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurorehabilitation and neural repair Reliability of scores on the Stroke Rehabilitation Assessment of Movement (STREAM) measure. Physical therapy Does kinematics add meaningful information to clinical assessment in post-stroke upper limb rehabilitation? A case report Biomechanical assessment of Fugl-Meyer score: the case of one post stroke patient who has undergone the rehabilitation using hand exoskeleton controlled by brain-computer interface Reliability of shoulder range of motion comparing a goniometer to a digital level. Physiotherapy theory and practice Justification of triaxial goniometer for the measurement of joint rotation Virtual reality-based post-stroke hand rehabilitation. InMedicine Meets Virtual Reality 02 The SonicHand protocol for rehabilitation of hand motor function: A validation and feasibility study Mobile game-based virtual reality rehabilitation program for upper limb dysfunction after ischemic stroke. Restorative neurology and neuroscience Virtual reality based stroke recovery for upper limbs using leap motion Gesture therapy: A vision-based system for arm rehabilitation after stroke Improved kinematics and motor control in a longitudinal study of a complex therapy movement in chronic stroke A novel approach to monitor rehabilitation outcomes in stroke survivors using wearable technology. Proceedings of the IEEE Arm rehabilitation with a robotic exoskeleleton in Virtual Reality Use of a portable assistive glove to facilitate rehabilitation in stroke survivors with severe hand impairment Kinematic data analysis for post-stroke patients following bilateral versus unilateral rehabilitation with an upper limb wearable robotic system Robotic technology and stroke rehabilitation: translating research into practice. Topics in stroke Rehabilitation Upper extremity physical therapy for stroke patients using a general purpose robot. In2011 RO-MAN Arm stiffness during assisted movement after stroke: the influence of visual feedback and training Analysis of Behaviour and Movement of the Upper Limb in the Weights Handling Activities. Procedia Manufacturing Synergy-based FES for post-stroke rehabilitation of upper-limb motor functions A clinically feasible kinematic assessment method of upper extremity motor function impairment after stroke Automated rehabilitation system: Movement measurement and feedback for patients and physiotherapists in the rehabilitation clinic. Human-Computer Interaction A kinematic notation for lower-pair mechanisms based on matrices Introduction to theoretical kinematics: By JM McCarthy Robot manipulators: mathematics, programming, and control: the computer control of robot manipulators Usability and acceptability of technology for community-dwelling older adults with mild cognitive impairment and dementia: a systematic literature review The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies Estimation of IMU and MARG orientation using a gradient descent algorithm An efficient orientation filter for inertial and inertial/magnetic sensor arrays. Report x-io and University of Bristol (UK) The Denavit Hartenberg Convention. USA: Robotics Insitute Carnegie Mellon University Automatic generation of humanoid's geometric model parameters A wearable monitoring system based on inertial sensors to measure and control the lumbar spine motion USEQ: a short questionnaire for satisfaction evaluation of virtual rehabilitation systems Implementation of an electronic health records system in a small clinic: the viewpoint of clinic staff A telerehabilitation system for the selection, evaluation and remote management of therapies. Sensors Measuring the outcomes of using person-generated health data: a case study of developing a PROM item bank Cronbach's Alpha: Simple definition, use and interpretation" From StatisticsHowTo. com: Elementary Statistics for the rest of us The authors would like to thank Mohammad Ishrak Abedin for designing the illustrative images for each therapy in the UI.We would also like to thank the physiotherapists for their valuable insights, system feedback and immense support in dealing with the patients and conducting the therapeutic interventions. This research was awarded the WINNER title at BASIS National ICT Awards 2020 under the category of Research and Development. It has been recently nominated for the APICTA Awards 20/21.