key: cord-0530494-pg1jwirb authors: Dikici, Engin; Nguyen, Xuan V.; Bigelow, Matthew; Ryu, John. L.; Prevedello, Luciano M. title: Advancing Brain Metastases Detection in T1-Weighted Contrast-Enhanced 3D MRI using Noisy Student-based Training date: 2021-11-10 journal: nan DOI: nan sha: e11871631003a6a9377101a9c178da51cb2e417c doc_id: 530494 cord_uid: pg1jwirb The detection of brain metastases (BM) in their early stages could have a positive impact on the outcome of cancer patients. We previously developed a framework for detecting small BM (with diameters of less than 15mm) in T1-weighted Contrast-Enhanced 3D Magnetic Resonance images (T1c) to assist medical experts in this time-sensitive and high-stakes task. The framework utilizes a dedicated convolutional neural network (CNN) trained using labeled T1c data, where the ground truth BM segmentations were provided by a radiologist. This study aims to advance the framework with a noisy student-based self-training strategy to make use of a large corpus of unlabeled T1c data (i.e., data without BM segmentations or detections). Accordingly, the work (1) describes the student and teacher CNN architectures, (2) presents data and model noising mechanisms, and (3) introduces a novel pseudo-labeling strategy factoring in the learned BM detection sensitivity of the framework. Finally, it describes a semi-supervised learning strategy utilizing these components. We performed the validation using 217 labeled and 1247 unlabeled T1c exams via 2-fold cross-validation. The framework utilizing only the labeled exams produced 9.23 false positives for 90% BM detection sensitivity; whereas, the framework using the introduced learning strategy led to ~9% reduction in false detections (i.e., 8.44) for the same sensitivity level. Furthermore, while experiments utilizing 75% and 50% of the labeled datasets resulted in algorithm performance degradation (12.19 and 13.89 false positives respectively), the impact was less pronounced with the noisy student-based training strategy (10.79 and 12.37 false positives respectively). radiation [1] . Contrast-Enhanced 3D Magnetic Resonance imaging is the key modality for the detection, characterization, and monitoring of BM. However, the task can become challenging when BM lesions are very small; their low contrast and structural similarities with surrounding structures (in some slice angles) may obstruct/limit their visual detection [2] . The automated detection/segmentation of BM in MRI data via machine learning (ML) was investigated in several studies [3] - [8] ; Cho et al. [9] provided a literature review study on the topic comparing state-of-the-art (SOTA) approaches based on the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) [10] and Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria [11] . We previously introduced a framework for T1-weighted Contrast-Enhanced 3D MRI [4] (analyzed among other SOTA approaches in [9] ) for the detection of BM with diameters less than 15mm to assist early detection of disease. The noisy student (NS) based self-training approach was first introduced in [12] to enable the usage of large amounts of unlabeled (i.e., not segmented or annotated for ML training) datasets to improve the accuracy of existing ML-based solutions. While the approach is still new as of the writing of this manuscript, it has already been utilized in various domains including medical imaging. In [13] , the NS method was employed for abdominal organ segmentation in 3D Computed Tomography (CT) datasets. The study utilized 3D nnU-Net [14] as both the teacher and student models, trained with 41 labeled and 363 unlabeled datasets. It reported ~3% improvement in the Dice similarity coefficient (DSC) due to unlabeled data. Rajan et al. [15] used the approach for multilabel classification of chest X-ray images. In addition to classical image augmentations, the method also utilized mixup [16] and confidence tempering regularizations for the noisy student model's training. Their results showed that a ResNet-18 [17] trained via their scheme with 12.5k labeled and 15k unlabeled samples could outperform a similar model trained using a 138k labeled set. In [18] , Shak et al. proposed an NSbased lung cancer prediction framework for CT images, where a DeepSEED network [19] was trained using labeled Lung Image Database Consortium image collection (LIDC) [20] and unlabeled National Lung Screening Trial (NLST) [21] datasets. The applicability of the NS for the segmentation of intracranial hemorrhages in CT was presented in [22] . The study included 456 labeled and 25K unlabeled head CT exams for the semi-supervised training of a PatchFCN [23] , producing a ROC area under the curve (AUC) of 0.939 for the B CQ500 dataset [24] . Kim et al. [25] utilized the NS for the quantification of severity and localization of COVID-19 lesions on chest radiographs. Their framework consisted of a Vision Transformer-based [26] backbone, trained using ~1000 labeled and ~190k unlabeled images collected from public datasets (i.e., [27] , [28] ), and provided results comparable to the expert radiologists'. Lastly, [29] proposed a cascaded learning approach for whole heart segmentation in CT angiography data. The method employed a V-net-based backbone [30] and advanced the NS with a shape-constrained training, producing a Dice coefficient of 0.917 with only 16 labeled and 64 unlabeled 3D images. The goal of this study is to advance the BM detection framework [4] via an NS-based self-training strategy. Thus, we aim to utilize unlabeled T1c data in a semi-supervised fashion to improve BM detection performance. To this end, we propose to use (1) the CropNet architecture as the teacher model and (2) a higher depth version (with higher capacity) of the same network as the student model to enable knowledge expansion. Next, we introduce a novel pseudo-labeling strategy that factors in the framework's target BM detection sensitivity during the paired training (i.e., using paired samples with and without BM) of the framework. The models are trained iteratively using a smaller group of labeled and a larger group of unlabeled data, pseudo-labeled using the introduced strategy. We suggest using the noising process for both the teacher and student models, where the (1) model noise was generated via Dropout layers, and (2) data noise was generated via random elastic deformations, gamma corrections, and geometric image transformations. The proposed adaptation of the detection framework is illustrated in Fig. 1 . This manuscript first provides a brief overview of the BM detection framework. Then, it describes (1) the model architectures, (2) noising mechanisms, and (3) NS-based semisupervised training setup introducing a pseudo-labeling strategy. The results section summarizes the experiments performed using two-fold cross-validation (CV) on 217 labeled and 1247 unlabeled T1c exams. It presents comparative analyses for (1) the frameworks trained with and without the given NS-based strategy, and (2) hyperparameters regarding the NS-based training process. Next, the results are discussed, where the framework is compared with other SOTA approaches via metrics including the BM detection sensitivity and false BM detection count. The report is concluded with a summary of the novelties of the introduced study and future work considerations. The BM detection framework consists of two major stages: (1) Candidate tumor detection and (2) classification of the candidates. The candidate selection procedure adapts the Laplacian of Gaussian (LoG) [31] approach for maximizing the BM detection sensitivity while minimizing the number of candidates [4] . The detected candidates are then used as centers of the volumetric region of interests (ROIs) processed by the CropNet, a convolutional neural network to classify a given RoI as BM or not. The CropNet processes isotropically sampled cubic ROIs with each voxel representing 1mm 3 . It inherits a contracting network architecture, where (1) each resolution level is processed via a set of blocks consisting of convolution, rectified linear activation unit, and dropout layers, and (2) the resolution downsampling is performed via max-pooling layers. The input volume's dimensions and the network's blocks per resolution level are denoted in the model's name; e.g., CropNet-bX-Ymm describes a network with X blocks per resolution level that processes cubic regions with the edge length of Y mm. The LoG approach produces thousands of candidates (i.e., ~70k) for each 3D dataset; hence, the ROIs with BM are underrepresented. Thus, the framework employs a paired training strategy, where each training data batch has an equal number of positive and negative samples (i.e., ROIs with 1-BM and 0-non-BM). The binary cross-entropy loss for this classification problem is minimized during CropNet's training. During the NS training, the student model capacity needs to meet or exceed the teacher model's to enable knowledge expansion (e.g., EfficientNet-B7 and EfficientNet-L2 were used as the teacher-student pair in [12] , presenting a sevenfold network capacity scaling). Accordingly, we utilized dedicated BM classification models CropNet-b2-16mm and CropNet-b4-16mm as the teacher-student pair in this study. The network architectures for these models are shown in Fig. 2 . The noising mechanisms are necessary for improving the generalizability of the neural networks, especially in limiteddata scenarios most medical imaging studies suffer from [32] . They are also critical for NS-based self-training strategies to enforce invariances in the decision function during the training of the student model. We deployed both the model and data noising mechanisms in this study: The data noising was applied via random Simard-type 3D deformations, gamma corrections, rotations, and image flips, whereas the model noising was provided via dropout layers (see Fig. 3 ). The labeled data set is initially processed via the constrained LoG algorithm to generate BM candidates for the given data. The candidates and the manual BM annotations are then used for producing a set of ROI volumes with their corresponding labels (1: BM, 0: non-BM), where is a paired set with an equal number of positive and negative samples. The teacher model is trained with the data noised version of the extracted ROIs by minimizing the binary crossentropy type loss function as: (1) After the training of the teacher model, the unlabeled data is processed using the constrained LoG algorithm to generate BM candidates. As there are no annotations for the unlabeled data, the pseudo-labels need to be generated. The framework produces BM detections based on a model response threshold , determined using the BM detection sensitivity. Thus, the relationship between the threshold and the teacher model sensitivity (ts) can be learned from the training data. Accordingly, we compute the sensitivity in relation to the false BM detections generated by on , and set a response threshold based on this value; for the unlabeled ROIs , pseudo-labels are determined by (see Fig. 4 ), The student model is optimized using both labeled and pseudo-labeled data as, where determines the weight of the unlabeled data on the final loss. In [12] , their loss equally weighted the labeled and pseudo-labeled parts of the equation by normalizing these with the corresponding sample counts. Hence, their solution could be considered as a special case of our formulation with . After the generation of the student model, it replaces the teacher model. A new student model(s) could be trained iteratively following the same procedures. The suggested algorithm has three hyperparameters; , and student model iterations. As is determined based on the teacher model's sensitivity for the training data, we suggest the usage of a value derived for the model's peak sensitivity. The motivation behind this choice is to allow the detection of most of the BM, even this may lead to more false-positive pseudo-labels. The alternative choice of setting for a lower sensitivity would lead to highly accurate pseudo-labels, whereas the challenging BM detections with low are excluded from the student model's training. We suggest adopting the value of 1.0 and performing a single student model iteration, as each iteration requires an extensive amount of computational resources where the resulting performance boost decays significantly after the first iteration. The effects of changing these parameters were presented via experimental studies. The data was collected retrospectively following Institutional Review Board Approval with a waiver of informed consent (institutional IRB ID: 2016H0084). The labeled data included 217 post-gadolinium T1-weighted 3D MRI exams (contrast agent: gadoterate meglumine -0.1 mmol/kg of body weight) and their corresponding BM segmentation masks. The exams were acquired between 01/2015 and 02/2016 from 158 patients; 113 patients had a single, 33 patients had two, 10 patients had three, and two patients had four imaging exams. The group had (1) mean age of 62 (σ = 10.5) and (2) sex ratio (males:females) of 0.89. They were selected based on finalized brain MRI reports generated by a neuroradiologist, where the exams with reports detailing primarily parenchymal enhancing metastases, ideally those undergoing surveillance for radiation therapy/radiation treatment planning, were selected. Patients with metastases larger than 15mm in diameter, primary brain neoplasms, central nervous system lymphoma, extra-axial disease, leptomeningeal disease, or equivocally enhancing foci were excluded. The BM segmentation masks were then generated by a fourth-year radiology resident, using the finalized examination report and/or annotated Picture Archiving and Communication System (PACS) images to ensure all BM were correctly delineated. The unlabeled data included 1247 post-gadolinium T1weighted 3D MRI exams, acquired between 11/2016 and 12/2019 from a non-overlapping group of 867 patients (i.e., no common patients between the labeled and unlabeled data). 579 patients had a single, 208 patients had two, 68 patients had three, and 12 patients had four MRI exams. The group had (1) mean age of 56 (σ = 14.5) and (2) sex ratio of 1.09. These patients were selected based on the diagnosis codes for malignant neoplasm(s) and/or secondary malignant brain neoplasm(s). The dimensional and distribution properties of BM used in this study, and the scanner information and the acquisition parameters are provided in Appendix. The average number of false positives-AFP (i.e., the count of falsely detected tumor locations) in connection with the detection sensitivity (i.e., the percentage of the actual BM detected) was used as the validation metric. We assumed a tumor is detected if the framework generates a detection up to 1.5mm apart from the tumor's center. The metric provides a relevant measurement for the algorithm's applicability in reallife deployment scenarios as (1) the sensitivity of a detection system is critical, and (2) the number of false positives needs to be low to ensure the system's feasibility for optimal clinical workflow. Accordingly, it was employed in various SOTA BM detection studies, including [3] , [4] , [6] , [33] . The approach was validated using a two-fold CV. The CV bins were set based on patients (i.e., the data from each patient can only occur in a single bin), where each bin included the labeled data from 79 patients. For each CV-fold, with the LoG candidate detector tuned as in [4] , the setup generated ~72K BM candidates and captured ~95% of the actual BM centers in the training bin. The teacher model was paired-trained using the labeled data in the training bin with its corresponding BM candidates. The teacher model's response threshold was determined by targeting the detection sensitivity (ts) of 90% for the training bin. Next, the student model was pairedtrained using (1) the labeled data in the training bin, (2) the unlabeled data that was pseudo-labeled by the teacher model, and (3) their corresponding BM candidates. The hyperparameter of the student model loss was set to 1.0. Finally, both the student and teacher models were tested for the testing bin (having no overlapping patients with the training bin and unlabeled data), generating the AFP versus sensitivity charts (see Fig. 5 ). The teacher model produced AFPs of 2.95, 5.74, and 9.23 for the 80%, 85%, and 90% detection sensitivities, respectively. The student model produced AFPs of 2.91, 4.82, and 8.44 at the same sensitivity levels (please note that teacher model performance closely mimics the BM detector proposed in [4] as they both employed identical model architectures and were trained using similar labeled data). Accordingly, the AFP reduction for the 90% BM detection sensitivity was ~9% (from 9.23 to 8.44) for the introduced strategy. Fig. 6 presents a set of example BM detections for the framework. The teacher (CropNet-b2-16mm) and student (CropNet-b4-16mm) networks consisted of ~14M and ~32M trainable parameters respectively. The networks had architectures described in Section 2.2, processing cubic ROIs with 16mm edges. The models' dropout rates were set at 0.15. The model optimizations were performed using the Adam algorithm [34] with (1) the learning rate of 0.00005 and (2) exponential decay rates for the first and second-moment estimates of 0.9 and 0.999, respectively. Both models were trained using 12000 batch-training iterations, without an early stopping condition. Each batch included (1) 150 positive and 150 negative samples for the teacher models, and (2) 75 positive, 75 pseudo-labeled-positive, 75 negative, and 75 pseudo-labeled- negative samples for the student models. The implementation was performed using the Python programming language (v3.6.10), and the neural networks were created using the TensorFlow (v1.12.0) library. The training times for the teacher and student models were ~7.25 and ~10.5 hours respectively, using an NVIDIA Tesla V100 graphics card with 32 GB RAM. The introduced noisy student-based self-training strategy has three input parameters (i.e., μ, λ, and student model iterations), where the reasoning behind their default values was provided previously. We performed three analyses to illustrate the effects of these parameters, and an additional one to present the impact of labeled data amount in our application. The response threshold ( ) for setting the pseudo-labels is determined based on the teacher model's detection sensitivity (ts) for the training data (see Eqn. (2)). In our proposed solution, we set ts=90% as the value is close to the maximum BM detection sensitivity the teacher model can achieve. In this analysis, values were determined via setting the teacher model's detection sensitivity to 80% and 85% for the training bin; hence, the impact of more specific yet less sensitive pseudo-labels was evaluated. The other parameters (i.e., and a single student model iteration) were kept unchanged during the experiment. Fig. 7 and Table I present the findings of this analysis. The analysis aimed to represent the impact of reducing pseudo-labeled data weight during the student model's training. We achieved this by evaluating the student models derived with and ( is the default value, see Eqn. (3)). The other parameters were kept at their default values during the experiment (i.e., ts=90% and a single student model iteration). Please see Fig. 8 and Table II for the results. The experiment targeted to assess the effect of further student training iterations, which are not part of our default Results with and a single student model iteration. The gray column corresponds to the default setup. solution due to low expected performance gains with a high additional computational cost. More explicitly, the student model from iteration-n (i.e., ) was used as the teacher model in the next iteration; becomes and generates pseudolabeled data for the training of . We performed two additional training and testing iterations for the experiment (i.e., the student model iterations 2 and 3), where the other default parameters were kept unchanged (ts=90% and ). Please see Fig. 9 and Table III for the corresponding results. Finally, we evaluated the teacher and student models with a reduced number of labeled training data. Firstly, we randomly kept 75% of patients in the training bins (i.e., 60 patients), and trained the teacher and student models using the labeled data collected from these randomly selected patients and the complete set of unlabeled data. The test bins were kept unchanged, and the default noisy student parameters were used during the analysis (i.e., ts=90% and a single student model iteration). Next, the experiment was repeated by randomly keeping 50% of patients in the training bins (i.e., 40 patients). Fig. 10 and Table IV present the findings of this experiment. The validation study showed that the sensitivity-based NS training improves the framework performance by reducing the AFP count (i.e., 9.23 to 8.44 at 90%, and 5.74 to 4.82 at 85% BM detection sensitives). The algorithm's parameters need to be set properly to exploit its potential: (1) Using the peak teacher model sensitivity (ts) for the training data to determine , (2) adopting , and (3) performing a single student training iteration led to satisfactory results in our experiments, where the motivations for each of these choices and relevant experiments are provided. The first experiment showed that reduced teacher model sensitivity during pseudo-labeling (i.e., yielding more accurate yet less sensitive pseudo-labeled data) leads to higher AFP counts. As shown in Table I , setting ts value to 80% caused the framework to produce the AFP value of 10.84 at 90% detection sensitivity (AFP values for 80% and 85% detection sensitivities for this setup were also relatively higher compared with the results acquired for ts=90%). The NSbased training's effectiveness is partly due to the implicit data augmentation/enrichment it introduces. Accordingly, we argue that keeping the teacher model highly sensitive allowed the student model training with pseudo-labeled data representing high variability. Thus, this higher level of implicit data augmentation led to an improved BM detection performance. Results with ts = 90% and a single student model iteration. The gray column corresponds to the default setup. Results with ts = 90% and . The gray column corresponds to the default setup. The second experiment aimed to find the effect of reducing the weight of pseudo-labeled data during the student model training. We hypothesized two alternative outcomes for this analysis: (1) λ value behaves as an interpolator parameter between the teacher and student models, and (2) a reduced λ (<1.0) may cause the student-model to outperform the default setup (using λ=1.0) by limiting the drift towards pseudosamples, which have limited accuracy. The outcome supported the first one (i.e., interpolation hypothesis). Table II shows that the students generated with λ=0.6 and λ=0.8 had performances bounded by the teacher and default student models, where the λ=0.6 performed closer to the teacher model and λ=0.8 performed closer to the default student model respectively. Thus, the experiment's result also complements the first experiment by supporting the notion that a higher amount of novel information contributes to a better student model performance. The third experiment examined the student model's performance with further student training iterations. We have observed the highest framework performance after the first and second student model iterations, whereas it did not improve significantly after the third iteration (see Table III ). Our finding is consistent with [12] , showing that the student model performance converges to a value at an arbitrary student model iteration, beyond which the accuracy does not change noticeably. The final experiment aimed to quantify the impact of labeled training data amount on the framework's accuracy. Accordingly, we repeated the teacher, student model training and validation procedures using reduced percentages of the labeled data (i.e., 75% and 50%). The results show that the amount of labeled data is critical on the final performance; the student models produced 8.44, 10.79, and 12.37 false BM detections by utilizing 100%, 75%, and 50% of the labeled training data. Furthermore, we observed valuable performance improvement with the use of proposed NS-based training; it led to ~9% (from 9.23 to 8.44), ~12% (from 12.19 to 10.79), and ~11% (from 13.89 to 12.37) reduction in AFP counts in these experiments (see Table IV) . Table V presents comparative information between a group of SOTA BM detection frameworks (i.e., [3] - [8] , [33] ) and the proposed one. It provides (1) study patient counts, (2) neural network architectures, (3) data acquisition types, (4) dimensional information on detected tumors, (5) data partitioning during validation studies, and (6) test performances with regards to AFP and sensitivity. The data show that the potential advantages of our framework include (1) the detection of particularly small BM lesions with relatively low AFP and high sensitivity, and (2) the capability to utilize unlabeled datasets during its model training via the introduced NS-based strategy. In this study, we introduced a novel formulation of the NSbased self-training strategy, which is applicable for detection systems prioritizing low false-positive counts for arbitrary detection sensitivities. Next, we extended our BM detection framework for 3D T1c data with the introduced strategy. The analyses showed that the method reduced AFP by 9% (from 9.23 to 8.44) for 90% tumor detection sensitivity by utilizing 1247 unlabeled T1c exams. Future studies may (1) further validate the approach with larger and multi-institutional unlabeled datasets and (2) investigate the algorithm's integration in various medical applications performing object detection. A wide range of noising mechanisms can be employed The teacher (a-1) and student (a-2) models were trained using 75% of the labeled data. The teacher (b-1) and student (b-2) models were trained using 50% of the labeled data. The teacher (c) and student (d) models were compared for different labeled data utilization percentages. during the NS-based training, and the most appropriate selection may depend on (1) the data (i.e., type, amount, and characteristics) and (2) the deployed ML models. For instance, [12] utilized the stochastic depth approach for model noising [35] , which is applicable for very deep neural networks (e.g., [36] ), unlike the CropNet. The impact of a set of pertinent mechanisms such as (1) Mixup [16] , (2) constrained GAN ensembles [37] , and (3) stochastic dropouts [38] represent potential avenues for future research on the model noising aspect of the framework. The applicability of artificial intelligence (AI) in medicine (among other fields) has increased significantly due to advancements in ML over the recent years. Accordingly, there have been various efforts to integrate AI in radiology workflows [39] , [40] , where the AI-based medical imaging algorithms are deployed and updated periodically by utilizing a constant flow of annotated/labeled data. These workflows may also be adapted to use unlabeled data by adopting selftraining methodologies, such as the one described in this study. Hence, the deployed medical imaging models are highly relevant to radiology AI systems that could benefit from the massive collection of unlabeled data sets stored in PACS systems. The labeled data included 932 annotated BM, where (1) the mean number of BM per patient was 4.29 (σ = 5.52), (2) the mean BM diameter was 5.45 mm (σ = 2.67 mm), and (3) the mean BM volume was 159.58 mm 3 (σ = 275.53 mm 3 ). The probabilistic distribution function of BM, computed via rigid registration [41] of labeled data to a template scan, is presented in Fig. 11 . See Table VI for the scanner parameters. 3D T1-weighted contrast enhanced spoiled gradient-echo MRI sequence. f The same dataset was used for training and validation in this study and [13] . g Tumor volumes were not reported. The testing was done for 72 smaller tumors (1-10mm in diameter) and 17 larger tumors (11-26mm in diameter) separately. h Tumor volumes were not reported. The average size of tumors in the study were 10mm ± (standard deviation: 8mm). j The volumetric stats are for the labeled data. k Sensitivity was 81 percent for smaller tumors and 100 percent for larger ones. Clinical and economic outcomes of patients with brain metastases based on symptoms: an argument for routine brain screening of those treated with upfront radiosurgery Advanced imaging of brain metastases: from augmenting visualization and improving diagnosis to evaluating treatment response Automatic detection and segmentation of brain metastases on multimodal MR images with a deep convolutional neural network Automated Brain Metastases Detection Framework for T1-Weighted Contrast-Enhanced 3D MRI A deep convolutional neural network-based automatic delineation strategy for multiple brain metastases stereotactic radiosurgery Deep learning enables automatic detection and segmentation of brain metastases on multisequence MRI Automatic detection and segmentation of multiple brain metastases on magnetic resonance image using asymmetric UNet architecture Deep convolutional neural networks for automated segmentation of brain metastases trained on clinical data Brain metastasis detection using machine learning: a systematic review and meta-analysis Checklist for artificial intelligence in medical imaging (CLAIM): a guide for authors and reviewers QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies Self-training with noisy student improves imagenet classification AbdomenCT-1K: Is Abdominal Organ Segmentation A Solved Problem? Automated design of deep learning methods for biomedical image segmentation Selftraining with improved regularization for sample-efficient chest xray classification mixup: Beyond empirical risk minimization Deep residual learning for image recognition A new semi-supervised self-training method for lung cancer prediction DeepSEED: 3D squeeze-and-excitation encoderdecoder convolutional neural networks for pulmonary nodule detection The lung image database consortium (LIDC) and image database resource initiative (IDRI): a completed reference database of lung nodules on CT scans The national lung screening trial: overview and study design Noisy Student learning for crossinstitution brain hemorrhage detection PatchFCN for intracranial hemorrhage detection Development and validation of deep learning algorithms for detection of critical findings in head CT scans Severity Quantification and Lesion Localization of COVID-19 on CXR using Vision Transformer An image is worth 16x16 words: Transformers for image recognition at scale Chexpert: A large chest radiograph dataset with uncertainty labels and expert comparison Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists' detection of pulmonary nodules Few-shot Learning by a Cascaded Framework with Shape-constrained Pseudo Label Assessment for Whole Heart Segmentation V-Net: Fully Convolutional Neural Networks for Volumetric Medical Image Segmentation Scale selection properties of generalized scale-space interest point detectors U-net: Convolutional networks for biomedical image segmentation Computer-aided detection of brain metastases in T1-weighted MRI for stereotactic radiosurgery using deep learning single-shot detectors Adam: A Method for Stochastic Optimization Deep networks with stochastic depth Efficientnet: Rethinking model scaling for convolutional neural networks Constrained generative adversarial network ensembles for sharable synthetic medical images Analysis on the dropout effect in convolutional neural networks An Orchestration Platform that Puts Radiologists in the Driver's Seat of AI Innovation: A Methodological Approach Integrating AI into radiology workflow: levels of research, production, and feedback maturity field strength, b repetition time, c echo time, d pixel size is same in x and y directions