key: cord-0485713-pxjuk5j0 authors: Chong, Kai Leong; Ng, Chong Shen; Hori, Naoki; Yang, Rui; Verzicco, Roberto; Lohse, Detlef title: Extended lifetime of respiratory droplets in a turbulent vapour puff and its implications on airborne disease transmission date: 2020-08-04 journal: nan DOI: nan sha: ec994d2b817c7aeea4c0b6e7ec8a9f0a852cec27 doc_id: 485713 cord_uid: pxjuk5j0 To mitigate the COVID-19 pandemic, it is key to slow down the spreading of the life-threatening coronavirus (SARS-CoV-2). This spreading mainly occurs through virus-laden droplets expelled at speaking, coughing, sneezing, or even breathing. To reduce infections through such respiratory droplets, authorities all over the world have introduced the so-called"2-meter distance rule"or"6-foot rule". However, there is increasing empirical evidence, e.g. through the analysis of super-spreading events, that airborne transmission of the coronavirus over much larger distances plays a major role with tremendous implications for the risk assessment of coronavirus transmission. Here we employ direct numerical simulations of a typical respiratory aerosol in a turbulent jet of the respiratory event within a Lagrangian-Eulerian approach with 5000 droplets, coupled to the ambient velocity, temperature, and humidity fields to allow for exchange of mass and heat and to realistically account for the droplet evaporation under different ambient conditions. We found that for an ambient relative humidity RH of 50% the lifetime of the smallest droplets of our study with initial diameter of 10 um gets extended by a factor of more than 30 as compared to what is suggested by the classical picture of Wells, due to collective effects during droplet evaporation and the role of the respiratory humidity, while the larger droplets basically behave ballistically. With increasing ambient RH the extension of the lifetimes of the small droplets further increases and goes up to 150 times for 90% RH, implying more than two meters advection range of the respiratory droplets within one second. Smaller droplets live even longer and travel further. Our results may explain why COVID-19 superspreading events can occur for large ambient RH such as in cooled-down meat-processing plants or in pubs with poor ventilation. penetrate more deeply into the lungs. These aerosols can accumulate, remain infectious in indoor air for hours, and be easily inhaled deep into the lungs. Interestingly, in spite of the major research effort of the last months in particular, the role of environmental factors such as temperature and humidity remains controversial and inconclusive [44, 45] . Various researchers have tried to establish empirical relations between the temperature and the humidity and the number of infections, but given that presumably most infections have happened indoors, it is not surprising that such efforts have remained unsuccessful [7, 44, 45] . The main difficulty in getting conclusive and reproducible results originates from the lack of controlled conditions under which the spreading events occur. However, controlled experiments under well-defined conditions such as flow rate, droplet size distribution, temperature, and relative humidity are very difficult to achieve and even with controlled and reproducible conditions, following 1000s of microdroplets in space and time remains extremely challenging. A good alternative thereof are direct numerical simulations. These not only allow to follow 1000s of microdroplets in turbulent flow, but also to straightforwardly vary the control parameters such as the droplet density, the type and strength of ventilation, the ambient temperature and the ambient relative humidity, in order to elucidate how these control parameters affect the lifetime of the respiratory droplets. In this way we want to elucidate the flow physics of these droplets, with the ultimate goal to be able to take suitable countermeasures against the spread of the coronavirus and thus to reduce the COVID-19 reproduction factor R. However, such direct numerical simulations are highly nontrivial, too. It has been attempted with Euler-Lagrangian approaches with Reynolds-averaged Navier-Stokes (RANS) approximations for a single droplet [46] , for multiple droplets [47] [48] [49] and large eddy simulations (LES) [50] , which however are insufficient to properly resolve the small scales of the mixing process, which are crucial for the droplet evaporation. Also temperature and humidity fields are not fully coupled, which however determine the evaporation rate and thus the lifetime of the droplets and are essential to properly describe their collective effects. The importance of these couplings have indeed been recognized in simulations of other aerosols, such as in combustion [51] . Other attempts include simulations with continuum models [52, 53] or mathematical models [54, 55] . To overcome these difficulties and to take the full physics into account, here we perform direct numerical simulations of a respiratory event without flow modelling, with the temperature and humidity field fully coupled to the Navier-Stokes equation, and 1000s of droplets of a given initial size distribution (adopted from experiment [56] ) treated in an Euler-Lagrangian way, with mass and temperature exchange with the environment to allow for evaporation and condensation, similarly as ref. [57] . This is only possible thanks to a highly efficient and parallelized advanced finite difference Navier-Stokes solver ("AFiD") based on a second-order finite difference scheme [58] , coupled to the advection equations for temperature and vapor concentration, both in Boussinesq approximation [59] . Details of the numerical scheme and setup are given in the Method Section (supplementary material). The objective of this numerical work is not only to elucidate the flow physics of a respiratory event and in particular how and why the lifetime of the respiratory droplets is hugely increased as compared to the case of isolated droplets and how this depends on the ambient conditions such as the ambient humidity, but also to sketch the essential ingredients of a numerical tool, which can be used for further parameter studies and more complex situations of respiratory events, in particular in indoor situations. We simulated a turbulent puff sustained over a duration of 0.6 s into ambient air and laden with 5000 water droplets, mimicking a strong cough. In addition to the droplets, the turbulent puff expels hot, vapor saturated air with an initial temperature 34 • C and relative humidity 100% [22] . Both temperature and vapor fields are buoyant. As reference ambient conditions, we chose the typical indoor ambient temperature of 20 • C and varying relative humidity between 50% and 90%. The background airflow conditions can also be an important factor, e.g. with or without ventilation [56] . Here we chose Figure 1 : Visualisations of droplets in a heavy cough for RH = 50%: a-d, Snapshots of the droplet-laden cough simulation. At time t = 100 ms, the cough contains hot air with high moisture content. The hot moist air propagates (t ≈ 200 ms) and dissipates (t ≈ 400 ms) into the ambient surroundings. At t ≈ 400 ms, we show larger droplets falling out from the puff whereas smaller droplets remain protected and are carried along by the puff. a quiescent background field, but different types of ventilation could be embodied straightforwardly. The topic of distribution of the initial droplet sizes is in itself a subject of considerable importance and active debate [56, 60, 61] . Here, we seeded the respiratory event with droplets with initial diameters ranging between 10 µm and roughly 1000 µm, based on an experimental measurement [56] . Note that even smaller droplets could be added, but they would further extend the required CPU time and are not necessary to convey the main message of this work. The droplets and the turbulent puff are twoway coupled [57] , that is, the droplets exchange heat and vapor mass to their surroundings. Given the dilute nature of the dispersed phase, here, we neglected the momentum exchange. Post-expulsion, we tracked the cough and droplets up to several seconds, which is sufficient to reveal the physics of their collective evaporation. For more details on the underlying equations, the numerical simulations, and the values of the control parameters, both dimensional and non-dimensional, we refer to the Methods Section. We first describe our results for fixed ambient relative humidity of RH = 50%. Within about 200 ms from the start of the cough, droplets larger than about 100 µm are observed to immediately fall out from the 'puff', basically behaving ballistically. The associated distances of this fallouts typically range between 0.1 m and 0.7 m from the source (Fig.1d) . Indeed, this type of fallout has already been predicted in the 1930s by Wells [20, 21] , and also demonstrated in the cough and sneeze experiments by [22] . These typical distances appear to be the basis of the spatial separation guidelines issued by the WHO, CDC, and European Centre for Disease Prevention and Control on respiratory protection for COVID-19 [15] . However, droplets smaller than 100 µm behave completely differently. Note again that, according to the WHO definition, respiratory infections transmitted by these smaller droplets (diameter d ≤ 100 µm) are considered to be occurring through the droplet transmission route. Here we see that they are airborne anyhow: Indeed, whilst larger droplets basically fall downwards like a projectile following a parabola, the paths traced by such smaller droplets remain largely horizontal and form spirals, consistent with the airborne infection scenario. The physical explanation of the two very different behaviors is straightforward: Larger droplets fall under the influence of their own weight and are unperturbed by the surrounding airflow. In contrast, smaller droplets settle slower than the characteristic velocity of the surrounding fluid, and are therefore advected further by the local turbulent flow. This latter mechanism is intimately related to the 'airborne' transmission route for infectious diseases [62] . Thus, smaller droplets are clearly heavily influenced by the turbulent dispersive processes. That the smaller droplets tend to remain inside the humid puff has dramatic consequences on their lifetimes, which far exceed those of isolated droplets (Fig.2a,d) . Here we report results for ambient relative humidity (RH) of 50% and 90%, respectively. In the former case (RH = 50%), the droplets of 10 µm can live up to 60 times longer than the expected value by Wells, whereas in the latter case (RH = 90%), it can even become 100 to 200 times longer. These extended lifetimes are also confirmed by the much slower shrinkage rates of the droplet surface area as compared to the corresponding rate determined from the d 2 -law, which is valid for isolated droplets and which is the basis for Wells' theory and the 6-foot distance rule, see Fig.2b ,e. We now further describe the flow physics contributing to this highly extended lifetime of the small droplets. The first physical factor depends on the motion of droplets relative to their surrounding fluid. As shown in Fig.1d , smaller droplets have the tendency to be captured by the turbulent puff and move together with the fluid. This gives rise to smaller relative velocities and hence less evaporation due to the reduction of convective effects. In contrast, larger droplets tend to fly and settle faster than the surrounding fluid, thus evaporating faster than predicted by the d 2 -law, because the convective effects, carrying the evaporated vapor away from the droplet, are considerable. This rapid evaporation is shown in the faster shrinkage rate of the droplet surface areas in Fig.2b ,e. The second and more crucial factor is the influence of the humid air around the small droplets, originating from the humid puff and the ambient surroundings. In order to quantify this effect on the lifetime, we show the averaged relative humidity of the droplets throughout the simulation as function of the initial droplet diameter d in Fig.2c ,f. From this figure, we observe a clear non-monotonic behavior reflecting two different regimes. In the first regime for small droplets d = 10 − 100µm, the relative humidity takes higher values than the ambient, reflecting that the droplets are surrounded by nearly saturated humid vapor. As the initial droplet size increases, the relative humidity decreases because the settling speed increases and the droplets tend to stray from the puff (Fig.1d) . In the second regime, for large droplets d > 100 µm, however, we observe that the relative humidity increases with the increase in size. The reason is that larger droplets evaporate larger quantities of vapor per given time, which leads to higher relative humidity in their surroundings. This effect is very local, due to the strong shear around the falling droplets. Since the humid puff leads to extended droplet lifetimes, it is instructive to examine the propagation of the humidity field. Indeed, also in the case of dense sprays [32, 33] , the droplets' fate is determined by the vapor concentration field. Therefore, as pointed out above, the problem of droplet evaporation in a respiratory puff is intimately related to scalar mixing in turbulent flow [63, 64] . In Fig.3a ,b, we show the relative humidity in the puff as function of time and distance from the respiratory release event, in order to quantify the propagation of the puff after exhalation. Very soon after the respiratory event starts, moist air coming out of the mouth creates very high humidity region in the vicinity ≈ 0.3 m of the mouth in 0.2 s. Although the overall humidity rapidly decreases after the respiratory event stops, the puff continues to propagate because of the conservation of momentum with the puff edge growing proportionally as t 1/4 as predicted by Bourouiba et al. [22] , see the solid line in Fig.3 , which is an upper bound to our numerical results. Here we have considered a heavy, but single cough scenario, having 0.6 s duration. It should be noted that the travel distance and speed can be much further and faster in the case of continuous talking or successive coughing or sneezing [1, 50] . The question on how far the puff can spread in these cases can be answered based on our single cough simulation. The spatial-temporal plot in Fig.3a,b show that the edge of the puff propagates much faster than t 1/4 before the end of coughing. Therefore, for successive coughing with the puff advecting at a cycle average speed of 2 -3 m/s, the edge of puff can easily exceed 2 m in a second, while most of the droplets around 10 µm are still not evaporated because of the extended lifetime favored by the vapour puff. Droplets with an initial diameter even smaller than 10 µm will travel even further and live even longer. The extended lifetime of the small droplets can also be expressed in the so-called evaporation-falling curve, as introduced in the classical work by William F. Wells [20] . He derived the dependence of the lifetime of the droplet on its size, based on the d 2 -law for evaporation of an isolated droplet and on the droplet settling time, see the dashed horizontal curves in Fig.3c ,d. According to this classical theory by Wells, droplets below this line evaporate completely and thus should not exist. In those figures we now include the histograms of the counts of droplets at given size and time, based on our direct numerical simulations of the respiratory events at an RH of 50% and 90%, respectively. Note that the time (on the x-axis) is shifted to the expulsion time for each droplet, such that the history of each droplet begins at time = 0 s. Fig.3c ,d clearly show that a considerable number of small droplets do exist below the classical Wells curve, demonstrating that the classical Wells estimate is inappropriate and that small droplets can live much longer. If a background flow exists or in the case of successive respiratory events, these long-lived droplets can easily travel much farther than 2 m in a second as carried by the turbulent puff, as shown in the advected distances estimated in Fig.3c, [20] , i.e., based on the d 2 -law. According to this assumption, droplets should only exist above the dashed line, which, as can clearly be seen here, is not the case in the actual respiratory event. The blue axes below panels c and d show estimated advected distance of small droplets based on a cycle-averaged cough velocity of 2 m s −1 . Even smaller droplets with initial diameter below 10 µm live even longer and are advected even further. Up to now we have focused on two cases, namely with ambient relative humidity of 50% and of 90%, respectively. Now we repeat the numerical simulations for further ambient relative humidities in the window 50% ≤ RH ≤ 90%. From Fig.4a one can observe that the lifetime of the small droplets increases dramatically and even diverges to infinity at RH = 100%. The smaller the droplets, the more pronounced the effect. For the smallest respiratory droplets of this study with initial diameter d = 10 µm, for RH = 90% the lifetime extension is with a factor of about 127 as compared to the lifetime of a droplet behaving according to the Wells model, and even with a factor of 166 as compared to the lifetime of Wells model droplet at RH = 50%. Similarly, for slightly larger droplets with d = 20 µm, the lifetime extension remains significant with a factor of 84 and 109, respectively. The first reason for the dramatic increases in droplet lifetime seen in Fig.4a is a significantly reduced evaporation rate for larger ambient RH as the ambient gas is much closer to the saturated condition. What however also considerably contributes is that for larger ambient RH the vapour puff can be sustained for longer times and distances, as shown in Fig.4b . In such case, there is stronger protection from the vapour puff for larger ambient RH. By tracking the interactions between respiratory droplets with the local velocity, temperature, and vapour field within direct numerical simulations, we have demonstrated the huge difference between droplet lifetimes in an actual respiratory event, as compared to that predicted according to Wells' assumption. Our numerical results are qualitatively consistent with Bourouiba's multiphase cloud emission model [1] and, in fact, quantify it, but are inconsistent with Wells' classical model, on which the 6-foot distance rule is based. The reason is that Wells' model assumes that the droplets are isolated, i.e., have no interaction with the near velocity, temperature, and in humidity fields around the droplet, which is not the case in reality. Indeed, our study has conveyed that in particular the humid vapor exhaled together with the droplets must not be neglected, as the vapor concentration around the droplet remains high during the whole respiratory event and thereafter (see Fig.2a,d) , strongly contributing to the lifetime extension of the small droplets by orders of magnitude. In this sense the lifetime of the respiratory droplets is mainly controlled by the mixing [63] of the humidity field exhaled together with them, similarly as occurring for the lifetime of evaporating dense sprays, which is also controlled by the mixing of the vapor field [32, 33] . The relevant length scale for droplet evaporation is therefore not the diameter of the droplet itself (sub-millimeter), but the outer length scale of the surrounding turbulent velocity and humidity field, i.e., meters. The lifetime of respiratory droplets has, to-date, grossly been underestimated (see Fig.3 ). The extension of the droplet lifetime is so extreme that the smallest droplets (d =10 µm) of our study barely evaporate (lifetime extension by factor 35 at ambient relative humidity RH = 50% and even by factor 166 at RH = 90%) and are transported in an aerosolised manner. This finding contradicts the 'respiratory droplet' classification by WHO for d >5-10 µm droplets, which implies that droplets of these sizes fall ballistically. From our results, there is strong evidence that even smaller droplets with initial diameter d ≤ 10 µm will survive even far longer in aerosolised form, because of the protection from the turbulent humid puff. Our results also show that the lifetime extension of the respiratory droplets is the more dramatic the larger the ambient relative humidity, see Fig.4a . The reason lies in the longer lifetime of the local humidity field around the droplets for larger ambient humidity RH, consistent with the picture that the mixing of the local humidity field determines the droplet lifetime, see Fig.4b . This finding may explain why many COVID-19 superspreading events have been reported in indoor environments with large ambient relative humidity. Examples are densely packed pubs with poor ventilation or meatprocessing plants [10] , in which the cooling down of the ambient air leads to very high indoor relative humidities. Note that high outdoor relative humidity obviously also leads to enhanced droplet lifetime, but in the context of the COVID-19 spread seems less relevant to us as most infections seem to happen indoors, due to in general sufficient ventilation outside. To-date, the general measures to reduce the transmission of COVID-19 have mainly taken into account the mode of droplet transmission, leading to social distancing guidelines as the 6-foot rule [15] . The analysis of various super-spreading events [6, [8] [9] [10] [11] has revealed that this is not sufficient, and our findings explain why, namely because of the dramatically enhanced lifetime of respiratory aerosols and droplets: Even droplets with a diameter of 10 µm, which according to WHO terminology are called respiratory droplets and are claimed to be relevant only through the host-to-host infection route, can have a lifetime extension by a factor of 200. Consequently, in addition to the 6-foot rule, various measures should be taken to reduce the respiratory aerosol and droplet concentration in indoor environments [1] [2] [3] 6, 7, [12] [13] [14] [15] 24, 43] . This is of particular importance in the upcoming autumn and winter when people are forced to be indoors. Soper [65] , in his 1919 Science article "Lessons of the pandemic" (those days the so-called Spanish influenza) was right with his claim that "there is danger in the air in which they cough and sneeze" [65] . (With the knowledge of today, we must also add "speak", "sing", "scream", and even "breath" [1, 2, 4, 13, 56] .) Those days Soper came up with empirical rules to protect the population against this danger, namely (among others) "Open the windows -at home and at office" and "Suspects should wear masks" [65] . Today, we understand why Soper's empirical rules work and are so crucial for the mitigation strategy against COVID-19 spreading. Following these rules contributes to dilute and reduce the concentration of respiratory droplets and aerosols in indoor situations [6, 24] . Our present work contributes to this understanding and our approach -direct numerical simulations with fully coupled velocity, vapor concentration and temperature fields and point-like droplets -even has the potential to further quantitatively contribute: • First, indeed, face masks reduce or even block respiratory droplets entering indoor environments and have turned out to be a helpful measure against the spread of COVID-19 [15, 66] . This reduction of the droplet input in indoor environments is the main function of face masks; in addition, depending on their quality and specification, they can also reduce the inhalation of respiratory droplets, which is of course essential for health-care workers dealing with COVID-19 patients. • Second, efficient indoor ventilation concepts [56, 67, 68] are equally crucial, to advect the humid cloud with respiratory droplets out of the room or at least dilute its concentration. However, note that, on the one hand, the humid vapor field can be diluted and rapidly "dissipated" by ventilation, but on the other hand, it may lead to strong background flow, which results in long propagation distance. The relative strength of the two effects must be examined in detail in future research, and such indoor measures are becoming increasingly important after gradually resuming from lockdown. Our present work, however, also suggests a further and supplementary mitigation strategy against COVID-19 infections, or, to be more precise, against high indoor respiratory droplets concentration, namely: • Reduction of the ambient indoor relative humidity, as this helps to reduce the lifetime of the respiratory droplets and aerosols, see Fig.4 . Our results help to understand why these various mitigation strategies against COVID-19 are successful and legitimate, but we also anticipate that our present tool and approach will be a starting point for larger parameter studies and for further optimizing mitigation strategies such as ventilation and indoor humidity controlling concepts. The governing equations include the equations for gas phase and equations for droplets [57] . Both temperature and vapour concentrations are coupled to the velocity field by employing the Boussinesq approximation. The motion of the gas phase is assumed to be incompressible ∂u i /∂x i = 0, and governed by the momentum, energy, and mass fraction equations: The last term on the right-hand side of equation (1) represents the coupling of temperature and mass fraction to the momentum equation. For droplets, the spherical point-particle model is applied, and we consider the conservation of momentum (Maxey-Riley equation [69] ), energy, and mass as follows: where, u i , u i,n , and u i,f are the velocity of gas, droplets, and gas at the location of droplets, respectively. Similarly θ g , θ n , and θ g,n are in Kelvin and used to represent the temperature of gas, droplets, and gas at the location of droplets, respectively. ρ is the vapour mass fraction, r n the droplet radius, A n the surface area of the droplets, V n the volume of the droplets. Also p denotes the reduced pressure. h m is the heat transfer coefficient. L is the latent heat of vaporisation of the liquid. Equation (5) and equation (6) are closed using the RanzMarshall correlations [70] , which give us the estimation of h m and Sh drop for a single spherical droplet. h m r/(D g c p,g ρ g ) = 2 + 0.6Re where we have droplet Reynolds number Note that, by definition, Sh drop and Re drop are also functions of r. The realistic parameters needed are listed in Extended Data Table ( 1) and are obtained from [22] . The relative humidity at the location of the droplets is defined as P vap,drop /P sat = ρ vap /ρ sat,vap , where ρ vap is solved from equation (3). Here, we assume that the temperature is the same. Therefore, to calculate the local relative humidity, ρ sat,vap is first determined by the ideal gas law: where ρ sat,vap , P sat and R are the saturated vapour density, saturated pressure, and specific gas constant. And through the Antoine's relation, the saturated pressure can be written as P sat (θ g ) = 10 5 exp 11.6834 − 3816.44 226.87 + θ g − 273. 15 . To numerically solve the equations, we used our finite difference solver AFiD [58] with high-performance Message Passing Interface (MPI) and point-particle model. The size of the computational domain in dimensional form is 0.18 m (spanwise length) ×0.37 m (height) ×1.47 m (streamwise length) and is tested to be large enough to capture the cough vapour and spreading droplets. The grid points chosen is 256 × 512 × 2048 to ensure that enough resolution has been employed. The cough profile we apply is the gamma distribution of the formŨ cough (t) = U cough αt exp(−αt/4), where α = 60.9 s −1 such that the entire cough process lasts for about 0.6 s. For the initial droplet size, we employ a similar distribution as [22, 60] with 5000 droplets. The droplets are randomly positioned at the inlet and evenly injected in time. For the small droplets, we compute the 80% life time, i.e. the time needed to shrink to 80% of the initial diameter. However, the large droplets rapidly settle to the boundary before reaching this threshold, so their 80% life time cannot be directly determined. To overcome this, the life times of these cases are estimated using higher diameter thresholds (see Extended Data Table ( 2)). The thresholds are defined such that the number of droplets satisfying the thresholds are at least 97% of the initial number. Then, we measure the shrinkage time for each droplets and calculate the ratio of the shrinkage time and to the corresponding shrinkage time with Wells' assumption. In the assumption of Wells' model, the droplets are assumed to be unaffected by flow, so we have equation (7) and equation (8) equalling 2 and equation (5) becomes dθ d /dt = 0. The ambient temperature and ambient relative humidity remain unchanged with time. The Wells' shrinkage rate is computed using equation (6) as Extended Data Turbulent gas clouds and respiratory pathogen emissions: Potential implications for reducing transmission of COVID-19 The coronavirus pandemic and aerosols: Does COVID-19 transmit via expiratory particles? Airborne transmission route of COVID-19: Why 2 meters/6 feet of inter-personal distance could not be enough Visualizing speech-generated oral fluid droplets with laser light scattering Identifying airborne transmission as the dominant route for the spread of COVID-19 Reducing transmission of SARS-CoV-2 Transmission of COVID-19 virus by droplets and aerosols: A critical review on the unresolved dichotomy Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event Estimation of airborne viral emission: quanta emission rate of SARS-CoV-2 for infection risk assessment Investigation of a superspreading event preceding the largest meat processing plant-related SARS-Coronavirus 2 outbreak in COVID-19 outbreak associated with air conditioning in restaurant Consideration of the aerosol transmission for COVID-19 and public health The airborne lifetime of small speech droplets and their potential importance in SARS-CoV-2 transmission Exposure assessment for airborne transmission of SARS-CoV-2 via breathing, speaking, coughing and sneezing Airborne or droplet precautions for health workers treating coronavirus disease 2019? Lagrangian properties of particles in turbulence Turbulent dispersed multiphase flow Direct numerical simulation of turbulent flows laden with droplets or bubbles Direct numerical simulation of a confined three-dimensional gas mixing layer with one evaporating hydrocarbon-droplet laden stream On Air-Borne Infection: Study II. Droplets and Droplet Nuclei Air-borne infection Violent expiratory events: on coughing and sneezing Virological assessment of hospitalized patients with COVID-2019 The flow physics of COVID-19 World Health Organization. Modes of transmission of virus causing COVID-19: implications for IPC precaution recommendations: scientific brief World Health Organization. Infection prevention and control of epidemic-and pandemic-prone acute respiratory infections in health care (World Health Organization A super-spreader of COVID-19 in Ningbo city in China A single mass gathering resulted in massive transmission of COVID-19 infections in Malaysia with further international spread Diamond Princess COVID-19 Cases Visualization of sneeze ejecta: steps of fluid fragmentation leading to respiratory droplets Fluids and health: Disease transmission through the lens of fluid dynamics Dense spray evaporation as a mixing process Fine structure of the vapor field in evaporating dense sprays The evaporation of small spheres Fuel spray vaporization in humid environment An experimental investigation on the vaporization and combustion of methanol and ethanol droplets First data analysis about possible COVID-19 virus airborne diffusion due to air particulate matter (PM): The case of Lombardy (Italy) Airborne transmission of SARS-CoV-2: The world should face the reality Respiratory virus shedding in exhaled breath and efficacy of face masks Airborne transmission of severe acute respiratory syndrome coronavirus-2 to healthcare workers: a narrative review Aerodynamic analysis of SARS-CoV-2 in two Wuhan hospitals How can airborne transmission of COVID-19 indoors be minimised? Airborne route and bad use of ventilation systems as non-negligible factors in SARS-CoV-2 transmission The role of environmental factors to transmission of SARS-CoV-2 (COVID-19) A chronicle of SARS-CoV-2: Part-I -Epidemiology, diagnosis, prognosis, transmission and treatment How far droplets can move in indoor environments-revisiting the wells evaporation-falling curve Sneezing and asymptomatic virus transmission Influence of wind and relative humidity on the social distancing effectiveness to prevent COVID-19 airborne transmission: A numerical study On coughing and airborne droplet transmission to humans Puff trains in speaking produce long-range turbulent jet-like transport potentially relevant to asymptomatic spreading of viruses Modeling of turbulent dilute spray combustion Airflows inside passenger cars and implications for airborne disease transmission Understanding transmission dynamics of COVID-19-type infections by direct numerical simulations of cough/sneeze flows. T. of the Ind Estimation of viral aerosol emissions from simulated individuals with asymptomatic to moderate coronavirus disease 2019 Modeling the role of respiratory droplets in COVID-19 type pandemics Small droplet aerosols in poorly ventilated spaces and SARS-CoV-2 transmission Water droplet condensation and evaporation in turbulent channel flow A pencil distributed finite difference code for strongly turbulent wall-bounded flows From convection rolls to finger convection in double-diffusive turbulence The size and the duration of air-carriage of respiratory droplets and droplet-nuclei Modality of human expired aerosol size distributions Aerosol transmission of infectious disease Mixing versus stirring Turbulent mixing The lessons of the pandemic This 3-d simulation shows why social distancing is so important. The New York Times Displacement ventilation: available ventilation strategy for makeshift hospitals and public buildings to contain COVID-19 and other airborne diseases The fluid mechanics of natural ventilation Equation of motion for a small rigid sphere in a nonuniform flow Evaporation from drops Acknowledgements: This work was funded by the ERC Advanced Grant DDD, Number 740479 and by several NWO grants. The funders have no role in study design, data collection and analysis or decision to publish. The simulations were performed on the national e-infrastructure of SURFsara, a subsidiary of SURF cooperation, the collaborative ICT organization for Dutch education and research, and the Irish Centre for High-End Computing (ICHEC). Author contributions: C.S.N., K.L.C., and N.H. planned and performed code development and evaluated the data. C.S.N., K.L.C. and R.Y. performed simulations. C.S.N., K.L.C., N.H. and R.Y. analysed data. R.V. managed initial code development and supervised the simulations. D.L. initiated, designed, and supervised the project. All authors wrote the manuscript.Competing interests: The authors declare no competing interests.Correspondence and requests for materials should be addressed to D.L.