key: cord-0448025-tujqfam9 authors: Erdogan, R. Tufan; Alkhaled, Mohammed; Kaynak, Batuhan E.; Alhmoud, Hashim; Pisheh, Hadi Sedaghat; Kelleci, Mehmet; Karakurt, Ilbey; Yanik, Cenk; Sen, Zehra Betul; Sari, Burak; Yagci, Ahmet Murat; Ozkul, Aykut; Hanay, M. Selim title: Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems date: 2020-12-19 journal: nan DOI: nan sha: 74f0701db21dd8d14a01bdf6854d087369cca3fc doc_id: 448025 cord_uid: tujqfam9 Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by NEMS (Nanoelectromechanical Systems) based Mass Spectrometry, where charged and isolated analyte particles are generated by Electrospray Ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes towards the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes towards an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup and the operation capability under ambient conditions, the technique demonstrates that NEMS Mass Spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently. Nanoelectromechanical Systems (NEMS) are powerful tools capable of performing mass spectrometry (MS) on large analytes with masses typically > 10 MDa. [1] [2] [3] [4] [5] [6] [7] [8] [9] As such, they cover a mass range that is not accessible by conventional MS systems due to large mass-to-charge ratios (m/z) of analytes. [10] [11] [12] The analytes in this mass range include metallic, ceramic, and polymeric nanoparticles, in addition to quantum dots, large supramolecular assemblies, exosomes, viruses, and lipid vesicles, all of which have been so far outside the realm of commercial MS instruments. Only one MS technique, Charge Detection MS [13] [14] [15] [16] (CDMS) has been demonstrated to work at large mass values, spanning between several kDa to hundreds of MDa in mass range. CDMS works by carrying out a simultaneous measurement of the analyte charge in addition to its massto-charge (m/z) in order to derive the mass of the analytes, 17, 18 recently attaining high resolving power (>300) for species at several MDa range. 19, 20 Unlike CDMS and any other MS techniques that utilize m/z detectors, NEMS technology can directly measure the mass without any dependence on the charge state of the ions. This renders NEMS-MS immune to any discrepancies in the spectrum caused by identical species with different charge states which is regarded as an especially important advantage for characterizing nanoparticles. 21 Another salient feature of NEMS-based sensors is that they have a small form factor (since NEMS is a chip-based technology), potentially allowing them to be embedded in compact instruments leading to true portability and miniaturization. Paradoxically, this small form factor is one of the major drawbacks preventing NEMS-based Mass Spectrometry (NEMS-MS) from ubiquitous adoption as a fully realized MS technique. To perform NEMS-MS, analyte particles need to be transported to a NEMS beam vibrating at the resonance frequency. The resonating beam is typically a few micrometers long and several hundred nanometers wide. The vast majority of analyte particles accelerated towards the NEMS device land predominantly outside of the NEMS capture area (i.e. resonating beam area) and therefore do not register as landing events. This translates into a low analyte capture efficiency -4 the ratio of analyte particles detected by NEMS over the total particles used during the analysis. To ameliorate this limitation, researchers resorted to using ion optics 1, 3 or aerodynamic lensing 5, 6, 22 to transport and focus the stream of analytes emitted from a soft ionization system, such as Electrospray Ionization (ESI), towards the NEMS capture area in order to detect a sufficient number of analyte particles within a reasonable time frame. However, both ion optics and aerodynamic lensing in NEMS-MS systems require differential vacuum systems to operate. Differential vacuum systems are composed of multiple vacuum components leading to a delicate design, thus increasing the cost, size, and complexity of the system. Therefore, the whole instrument becomes encumbered by the vacuum setup, leading to a loss in its apparent advantages (miniaturization, portability, feasibility of mass-production etc.). In fact, even with the most optimized designs, the current state-of-the-art capture efficiency 5, 6 is still worse than 1 particle out of 20 million contained in the original solution which is not sufficient for analyzing real clinical samples. 23, 24 In order to eliminate the vacuum requirement while providing superior focusing performance, we have designed an architecture for NEMS-MS that can operate under atmospheric conditions, where the focusing of the analytes is accomplished on-chip ( Figure 1a ). On-chip ion focusing plays a critical role, since standard ion optics techniques do not work at atmospheric conditions: 25, 26 rather we were inspired by recent advances in nanopatterning 27 and microscale 3D printing 28 to form an integrated system. The on-chip ion lens is composed of a photoresist layer with an open window exposing the NEMS resonator. The photoresist layer charges up by accumulating part of the incoming ions on itself and establishes ion focusing onto the NEMS capture area (Figure 1b ). This way, it works as a self-biasing lens with the focusing region perfectly aligned with the NEMS capture area. 5 With this system, we have demonstrated efficient characterization of different nanoparticles and viruses in relatively low concentrations (< 1×10 10 Particles/mL) under atmospheric pressure with analysis time of typically 30 minutes. To our knowledge, atmospheric MS in this context was never achieved before. The integrated lens increased the capture efficiency of gold nanoparticles (GNPs) by several orders of magnitude exceeding the capture efficiencies reported by state-of-the-art NEMS-MS architectures in the literature. Furthermore, polystyrene nanoparticles were successfully focused and detected by the NEMS-MS device also under atmospheric pressure and with record capture efficiencies. Finally, as a proof of utility in the biomedical field, the NEMS-MS system as described was able to measure the mass of SARS-CoV-2 virions from cell lysate in addition to bovine herpes virus (BoHV-1). We believe that the development of this integrated lens approach will solve a major hurdle preventing the nanoscale mass detectors from reaching their true potential of high capture efficiency, atmospheric operation, versatility, and portability. The NEMS device is a suspended, doubly-clamped silicon nitride beam on a silicon substrate which vibrates mechanically in air. Standard nanofabrication procedures were used to fabricate the beam (10-15 µm long, 400-800 nm wide and 100 nm thick, typically) and deposit gold electrodes on the beam's top surface for integrated electronic transduction. 29, 30 The suspended devices were then spin-coated with a high-viscosity photoresist (AZ 4533) to a final layer thickness of 3.5 μm. After the deposition of the photoresist, the NEMS chip was exposed to ultraviolet (UV) light through an aligned photomask, followed by a development step to open a window in the photoresist layer that is aligned with the NEMS resonator ( Figure 1a ). This way the photoresist surrounds the NEMS structure and forms a polymeric lens to direct the incoming analytes towards the active 6 sensing area of the NEMS device. The polymeric focusing lens window on our device architecture is typically 20 microns long by 15 microns wide. After establishing the focusing ability of the polymeric lens on blank silicon chips, and optimizing the process parameters, we then used NEMS devices with integrated lenses to verify that self-focusing still takes place ( Figure 2e ). Critically, a considerable portion of the particles arriving at the focusing window were further focused and concentrated on the surface of the beam due to the tight alignment of the focusing lens with the NEMS device ( Figure 2f ). After establishing the focusing ability of the polymeric lens, we tested the performance of our NEMS-MS system using 40 nm and 20 nm gold nanoparticles, and 100 nm polystyrene nanoparticles (80 mM ammonium acetate buffer, pH 7.1, for further details see Methods). We first conducted experiments using 40 nm nominal diameter spherical gold nanoparticles (Sigma-Aldrich 741981). The concentration of the particles in the solution was 7.15´10 9 particles per mL 13 (Methods). Figure 4 shows the two mode PLL data of a 40 nm gold nanoparticle detection with a mass resolution of ~3.3 MDa (Supporting Figure S7 ). This reported mass resolution is suitable for resolving nanoparticles at the targeted range (typically > 50 MDa). The inset in Figure 4 shows two consecutive landing events registered by the NEMS device. While there is a slow drift in the PLL data, it does not significantly obscure the sharp frequency jumps induced by single particles on NEMS (other than slightly increasing the effective noise, e.g. Supporting Figure S7b ), which is a general characteristic of NEMS resonance detection. 3 To verify our NEMS based mass measurements, we set out to compare the results with common sizing techniques (SEM and DLS), by converting the mass histogram into a size histogram using the density of gold (19.27 g/cm 3 ) and assuming a spherical shape, (Figure 5b ). The size histogram 14 was in good agreement with the SEM measurements of the GNPs collected at the NEMS beam surface in the same experiment (Figure 5b ). Fitting the NEMS size histogram to a non-parametric density function we obtained a global maximum at 35.6 nm (~274 MDa, Supporting Figure S9 ). Once the size measurements by NEMS and SEM were shown to agree with each other, we then compared these results with dynamic light scattering (DLS). DLS showed a peak value higher than the actual diameter measurements obtained by SEM and NEMS-MS, as this technique probes the hydrodynamic diameter of the gold nanoparticles ( Figure 5b ) and yields results typically larger than the actual GNP diameter due to the changes in the intensity of scattered light as a function of particle diameter, solution concentration, and moieties adsorbed at the surface of the nanoparticles. 31, 32 To test the versatility of the atmospheric NEMS-MS, we repeated the same mass measurements on nominally 20 nm GNPs and 100 nm polystyrene nanoparticles (PSNP) at concentrations of 6.54x10 9 and 3. Once the system was benchmarked using gold and polystyrene nanoparticles, we switched to biological samples. A SARS-CoV-2 sample, isolated from a COVID-19 patient, and expanded in vitro, was analyzed first. The virus sample was harvested by applying a freeze-thaw cycle twice to lyse the cell culture. The cell lysate was then centrifuged to remove cell debris, followed by a short thermal inactivation for safety purposes (Methods, SARS-CoV-2 Virus Isolation). Before the thermal inactivation, SARS-CoV-2 samples had a concentration of approximately 2×10 6 PFU/mL as calculated by a viral plaque assay. The virus was isolated using PEG precipitation followed by dialysis at 4ºC to exchange the culture media with the ESI-compatible 80 mM ammonium acetate solution (pH 7.1). Dynamic Light Scattering (DLS) was then conducted on the sample to obtain the hydrodynamic diameter of the isolated virus in the sample and to confirm the absence of any other major particulates left over from the cell lysate. DLS characterization showed one major peak centered at 86 nm, assumed to mostly correspond to the virion particles, while no other major peaks were detected. The same sample, with virions diluted forty-fold, was then analyzed using NEMS-MS, resolving 153 single virion events within 14 minutes. The resulting mass spectrum is shown in (Figure 6a ) which was used to fit a non-parametric probability density function. The global maximum value for the density function is 454 MDa. To interpret this spectrum, first, we converted the mass values into effective diameter values, assuming that the SARS-COV-2 virions had a spherical shape and using a typical value for the viral mass density (1.4 g/cm 3 ). 33 After the conversion, the resulting diameter histogram was generated as shown in (Figure 6a particulates detected especially at the higher mass values, presumably originating from the cellular debris. However, above this background, a clear, population emerged at the expected location for SARS-CoV-2 with the major peak almost overlapping with the peak of the spectrum of the isolated virus (469 vs. 454 MDa respectively, for further statistics, see Supporting Table S5 ). It was not possible to measure the actual virion concentration prior to ESI, since the standard technique of plaque assay quantifies only the active viruses. Therefore, assessing the capture efficiency achieved through NEMS detection for the particular case of SARS-CoV-2 was not possible. Nevertheless, this work clearly establishes that NEMS-based Mass Spectrometry can now be used in more realistic and relevant biological samples with concentrations as low as 5×10 4 PFU/mL (and possibly lower due to losses during sample processing), and sample volumes as little as 7 μL. Moreover, this analysis was also done directly on complex media such as a cell lysate which eliminates the necessity for complex sample preparations. Therefore, the mammalian viruses such as SARS-CoV-2 can be detected and characterized based on its mass using NEMS-MS entirely under atmospheric conditions. Also, accomplishing the characterization of the viruses is very similar to the characterization of other nanoparticles owing to the high masses detectable under ambient conditions and over short durations. In this work, we have established a high-throughput system operating at ambient conditions for the direct mass measurements of individual particles and viruses. Although we used electrospray ionization to facilitate the transportation and focusing of the analytes, the NEMS MS technique does not need the charge state of the analyte to deduce its mass since the resonance frequency of the NEMS beam is a function of the mass but not the charge. Unlike recent trends for the use of neutral species, 4, 6 in this work we also show that the charged analyte particles, formed by the wellestablished ESI process, can be used as a resource to electrostatically bias the photoresist lens leading to ion focusing and an increase in capture efficiency. Before the use of ESI, 1 earlier work with MEMS/NEMS technology at ambient conditions such as the detection of E. Coli cells 38 and viruses, 39 were conducted by incubating the devices with analytes in liquid, and then drying the chips and measuring the resonance curves in air. However, due to the long duration involved for analyte capture (via diffusion) and drying process of the chips, as well as higher uncertainties involved in the measurements, these approaches did not evolve into automated, high-throughput systems. By contrast, the approach taken here, where ESI is utilized, resolves the capture and wetting problems by allowing the sprayed droplets to completely evaporate on their way to the chip-based resonator beam. Another approach to operate NEMS devices is the use of aerosol impaction. 22 In this approach, analyte nanoparticles are Apart from mass spectrometry approach, there are other approaches to determine the size (but not the mass) of large biological structures and nanoparticles such as IMS (Ion Mobility Spectrometry) and DLS. IMS measures the mobilities of ionic species and then uses an empirical correlation curve to relate the ion mobility to particle mass. 40, 41 However, the correlation curve is not ideal: for instance, the shape and type of the analyte as well as its charge state affects the mobility significantly. 42, 43 As such the mass values extracted from IMS are taken as indicative rather than actual mass values. Moreover, IMS systems require delicate instrumentation involving 22 air flows, increasing the size and cost of IMS equipment in a similar fashion to earlier NEMS-MS designs 3, 5, 6 but unlike our chip-based atmospheric pressure NEMS-MS technology. Another commonly used tool for size (hydrodynamic radius) characterization of nanoparticles is DLS which suffers from limitations especially in complex mixtures. 44 The scattering crosssection depends on the shape and material properties of the particles; and the signal intensity depends on the diameter of the particle with a sixth order dependency, creating misrepresentations in polydisperse samples. Moreover, parameters such as the solvent viscosity, surface functionalization etc. need to be known for correct calibration of the instrument. We also note that the results show that the NEMS-MS can be both more accurate and more precise than DLS. A more detailed discussion of NEMS-MS technology with other related techniques such as Mass Photometry, 45 thermophoresis, 46 and Gas-phase electrophoretic molecular mobility analyzers (GEMMA) 40 is provided in the Supporting Information. After evaluating the competing technologies, our self-focusing on-chip NEMS-MS system has been shown to provide clear and tangible advantages over current mass and size detection technologies that have been discussed. The major advance brought forward by our design is the elimination of vacuum requirements resulting in the miniaturization of the mass detector. Moreover, the integration of a photoresist focusing layer increases the capture efficiency of NEMS sensors by two orders-of-magnitude which decreases the analysis time significantly. In our opinion, these advances are critical components for the development of first generation commercial NEMS-MS systems that can be either portable or benchtop and that are capable of providing rapid analysis either at point-of-care or in research and development in the biomedical field. For such applications, the limiting factor is to miniaturize and accelerate the pre-processing protocol of samples, either by optimizing established methods (e.g. ultracentrifugation for buffer exchange) or by utilizing emerging techniques, such as deterministic lateral displacement 47 or asymmetrical flow-field fractionation. 48 The capabilities of such a system will also extend its utility to other disciplines such as the environmental sciences for pollution detection and air quality control. The integration of the ion lens allowed us to operate our entire system under ambient conditions with a mass resolution of ~ 3.3 MDa. The obtained mass resolution may seem modest, but for the large mass range (> several 100 MDa) considered for nanoparticle and virus applications, it is small enough to distinguish between two particles within this mass range. More importantly, the mass spectrum of engineered nanoparticles and viruses exhibit an inherent dispersion (e.g. because of the synthesis conditions, and the stochastic nature of virion formation including the number of spikes in the case of SARS-CoV-2). Therefore, the mass resolution attained under ambient conditions appears to be suitable to differentiate different species (e.g. by Figure 5 and Figure 6b inset) owing to the large mass values for the species targeted, as well as the inherently polydisperse mass distribution for each analyte. In this work, we have demonstrated mass spectrometry measurement of single nanoparticles at atmospheric conditions and obtained capture efficiencies several orders-of-magnitude larger than the earlier state-of-the-art, and with adequate mass resolutions by the on-chip integration of NEMS sensors with self-biased polymeric lenses. The integration of on-chip lensing with NEMS enhanced the capture efficiency and reduced the analysis time by several orders-of-magnitude. With this system, we have characterized different classes of nanoparticles and viruses, with an analysis time of less than thirty minutes. As this form of mass spectrometry operates entirely at ambient conditions, the constraints imposed by vacuum instrumentation are circumvented, which 24 contributes toward the development of miniature and field-deployable systems based on nanoscale sensors. Details of Micro/Nanofabrication. The NEMS sensor fabrication process consists of two main steps: first, the fabrication of a suspended doubly-clamped beam integrated with the transduction electrodes, and second, the creation of the electrostatic polymeric focusing lens aligned with the NEMS device. The NEMS sensor was fabricated from a 100 nm thick stoichiometric Silicon Nitride film on a 500 μm Silicon substrate (University Wafer). First, the metallization of the actuation and read-out electrodes along with the contact pads was performed. To this end, electron beam lithography (EBL) was used with Poly (methyl methacrylate) (PMMA) to pattern the electrodes. After PMMA development, 5 nm chrome adhesive layer and 70 nm gold layer was deposited using thermal evaporation. Then a second EBL process was carried out to define the mechanical structure consisting of the beam and clamping region. This was followed by a 40 nm copper deposition using thermal evaporation to be used as a hard mask in the following steps to suspend the beam. To suspend the beam, an anisotropic dry etch for Silicon Nitride, followed by an isotropic dry etch for Silicon was performed. Finally, the copper hard mask was removed using an isotropic wet etch. The NEMS sensor fabrication is described in detail in references. 30, 49 To create the polymeric lensing structure, a second major process was developed. We used a commercial photoresist to constitute the polymeric layer, due to ease of fabrication. To this end, high viscosity photoresist (AZ 4533) was coated to thickness of 3.5 μm over the beam as the final 25 step in the fabrication. Optical lithography was conducted to expose the beam area with UV light. After developing the exposed photoresist, the electrostatic polymeric lensing structure with a window over the beam was created. The window size was optimized both with respect to the dimensions of the NEMS sensors and considerations of the photolithography / development steps on suspended NEMS. Wire-bonding contact pads, which are placed approximately 400 μm away from the NEMS sensor, were also opened in the same step ( Figure 1 ). After wire bonding, the NEMS sensor including the photoresist focusing window is ready for measurement. Supporting Table S1 . These parameters were chosen to operate in the cone-jet ESI mode and avoid any electrical discharges. Gold Nanoparticle Preparation. The solutions containing 20 and 40 nm nominal diameter gold nanoparticles in citrate buffer were purchased from Sigma Aldrich (Sigma Aldrich 741965 and 741981 respectively). Using 80 mM Ammonium Acetate as the buffer (pH 7.1), serial dilutions were conducted until the final concentration was reached (Supporting Table S2 ). Due to the significant amount of dilution, no additional step for buffer exchange was conducted. The open-loop measurement and the PLL tracking of the first two resonance modes of the NEMS device were conducted using Lock-in-Amplifier (Zurich Instruments HF2LI) and the circuitry shown in Supporting Figure S6 . MATLAB was used to extract the frequency shifts that correspond to analyte landing events using the slope of the frequency data as a criterion. Events with frequency shift values within noise level and outliers were excluded. The total NEMS device mass was calculated using dimensions acquired by SEM. The mode shape for each vibrational mode is extracted from COMSOL by fitting the resonance frequencies to experimental values. This data were then used to calculate the mass and landing position of each event and ultimately to construct mass spectra as discussed in the literature. 3 In this technique, each event is assumed a probability density function (PDF) which is then converted into PDF in the mass-position plane using the established relationships. The mean and standard deviation values for each event were calculated and used to construct histogram plots. For each event, a Gaussian function with mean and standard deviation corresponding to the specific event is assumed. These single functions are then summed up and normalized to construct the mass spectra. For diameter spectra, mass spectra were converted using the density of the particle and assuming a spherical shape. Towards Single Molecule Nanomechanical Mass Spectrometry Nanomechanical Mass Sensor with Yoctogram Resolution Single-Protein Nanomechanical Mass Spectrometry in Real Time Neutral Particle Mass Spectrometry with Nanomechanical Systems Mass and Stiffness Spectrometry of Nanoparticles and Whole Intact Bacteria by Multimode Nanomechanical Resonators Mass Spectrometry of Virus Capsids above 100 Megadaltons with Nanomechanical Resonators Large-Scale Parallelization of Nanomechanical Mass Spectrometry with Weakly-Coupled Resonators Nonlinear Nanomechanical Mass Spectrometry at the Single-Nanoparticle Level Optomechanical Mass Spectrometry Electrospray Ionization for Mass Spectrometry of Large Biomolecules Protein and Polymer Analyses up to M/Z 100 000 by Laser Ionization Time-of-Flight Mass Spectrometry. Rapid communications in mass spectrometry Influence of the Wavelength in High Irradiance Ultraviolet-Laser Desorption Mass-Spectrometry of Organic-Molecules Mass Spectrometry of an Intact Virus Detection of Late Intermediates in Virus Capsid Assembly by 34 Charge Detection Mass Spectrometry Mass Determination of Entire Amyloid Fibrils by Using Mass Spectrometry Resolving Heterogeneous Macromolecular Assemblies by Orbitrap-Based Single-Particle Charge Detection Mass Spectrometry Direct Molar Mass Determination of Self-Assembled Amphiphilic Block Copolymer Nanoobjects Using Electrospray-Charge Detection Mass Spectrometry Optical Extinction and Scattering Cross Sections of Plasmonic Nanoparticle Dimers in Aqueous Suspension Resolving Adeno-Associated Viral Particle Diversity with Charge Detection Mass Spectrometry Higher Resolution Charge Detection Mass Spectrometry The Emergence of Mass Spectrometry for Characterizing Nanomaterials. Atomically Precise Nanoclusters and Beyond Real-Time Single Airborne Nanoparticle Detection with Nanomechanical Resonant Filter-Fiber Clinical Significance of a High Sars-Cov-2 Viral Load in the Saliva Separation, and Ion Detection in the Open Air in a Small Plastic Device Ion Transport and Focal Properties of an Ellipsoidal Electrode Operated at Atmospheric Pressure Parallel Patterning of Nanoparticles via Electrodynamic Focusing of Charged Aerosols Directed Assembly of Nanomaterials Using Electrospray Deposition and Substrate-Level Patterning Ultra-Sensitive Nems-Based Cantilevers for Sensing, Scanned Probe and Very High-Frequency Applications Efficient Electrothermal Actuation of Multiple Modes of High-Frequency Nanoelectromechanical Resonators On the Measurement of Gold Nanoparticle Sizes by the Dynamic Light Scattering Method Techniques for Accurate Sizing of Gold Nanoparticles Using Dynamic Light Scattering with Particular Application to Chemical and Biological Sensing Based on Aggregate Formation Monte Carlo Simulation of Sars-Cov-2 Radiation-Induced Inactivation for Vaccine Development Sars-Cov-2 Structure and Replication Characterized by in Situ Cryo-Electron Tomography Structures and Distributions of Sars-Cov-2 Spike Proteins on Intact Virions Morphometry of -2 Particles in Ultrathin Plastic Sections of Infected Vero Cell Cultures The Herpesviruses Single Cell Detection with Micromechanical Oscillators Single Virus Particle Mass Detection Using Microresonators with Nanoscale Thickness Virus-Like Particle Size and Molecular Weight/Mass Determination Applying Gas-Phase Electrophoresis (Native Nes Gemma) Analysis of a Common Cold Virus and Its Subviral Particles by Gas-Phase Electrophoretic Mobility Molecular Analysis and Native Mass Spectrometry Gas Phase Electrophoresis (Nes Gemma Instrumentation) Size and Molecular Weight Determination of Polysaccharides by Means of Nano Electrospray Gas-Phase Electrophoretic Mobility Molecular Analysis (Nes Gemma) Asymmetrical Flow Field Flow Fractionation Methods to Characterize Submicron Particles: Application to Carbon-Based Aggregates and Nanoplastics Quantitative Mass Imaging of Single Biological Macromolecules Deterministic Sorting of Submicrometer Particles and Extracellular Vesicles Using a Combined Electric and Acoustic Field Asymmetrical Flow Field-Flow Fractionation on Virus and Virus-Like Particle Applications. Microorganisms Intermodal Coupling as a Probe for Detecting Nanomechanical Modes Physicochemical Properties and Ion-Solvent Interactions in Aqueous Sodium, Ammonium, and Lead Acetate Solution. Russ The manuscript was written through contributions of all authors. All authors have given approval