key: cord-0426419-9q4800bl authors: Holmes, Niall; Rea, Molly; Hill, Ryan M.; Boto, Elena; Stuart, Andrew; Leggett, James; Edwards, Lucy J.; Rhodes, Natalie; Shah, Vishal; Osborne, James; Fromhold, T. Mark; Glover, Paul; Montague, P. Read; Brookes, Matthew J.; Bowtell, Richard title: Naturalistic hyperscanning with wearable magnetoencephalography date: 2021-09-07 journal: bioRxiv DOI: 10.1101/2021.09.07.459124 sha: e6b6eb89cec4c67e40d154c24610d9e029b51279 doc_id: 426419 cord_uid: 9q4800bl The evolution of human cognitive function is reliant on complex social interactions which form the behavioural foundation of who we are. These social capacities are subject to dramatic change in disease and injury; yet their supporting neural substrates remain poorly understood. Hyperscanning employs functional neuroimaging to simultaneously assess brain activity in two individuals and offers the best means to understand the neural basis of social interaction. However, present technologies are limited, either by poor performance (low spatial/temporal precision) or unnatural scanning environment (claustrophobic scanners, with interactions via video). Here, we solve this problem by developing a new form of hyperscanning using wearable magnetoencephalography (MEG). This approach exploits quantum sensors for MEG signal detection, in combination with high-fidelity magnetic field control – afforded by a novel “matrix coil” system – to enable simultaneous scanning of two freely moving participants. We demonstrate our approach in a somatosensory task and an interactive ball game. Despite large and unpredictable subject motion, sensorimotor brain activity was delineated clearly in space and time, and correlation of the envelope of neuronal oscillations between people was demonstrated. In sum, unlike existing modalities, wearable-MEG combines high fidelity data acquisition and a naturalistic setting, which will facilitate a new generation of hyperscanning. 1 Human social interaction is at the core of healthy neurodevelopment. From tactile stimulation 2 to the evolution of language, from information transfer to social development, how we interact with 3 others shapes everything from our abilities and skills to our personalities. However, relatively little is 4 known about the neural underpinnings of these interactions. The simultaneous recording of functional 5 brain imaging data from multiple people (hyperscanning) offers a powerful tool to probe brain activity imaging technology places severe limitations on experimental design, participant experience, and data 8 quality (Czeszumski et al., 2020) . We aim to address these issues by developing a fundamentally new 9 technique for hyperscanning, offering high performance, and the opportunity for naturalistic social 10 Functional magnetic resonance imaging (fMRI) offers assessment of brain activity with high 12 spatial resolution, but the requirement that participants be enclosed and motionless in a noisy scanner 13 makes natural interactions during hyperscanning impossible. Whilst MRI can be adapted to scan two video, but this also imposes barriers to natural interaction. In addition, the latency and longevity of the 18 haemodynamic signal makes it challenging to assess brain dynamics . 19 In contrast, functional near infrared spectroscopy (fNIRS) (Ferrari and Quaresima, 2012) and hyperscanning. However, fNIRS suffers poor spatial resolution and (like fMRI) is limited to 23 haemodynamic measurement. EEG, via assessment of scalp-level electrical potentials, directly 24 measures brain electrophysiology and consequently has excellent temporal resolution, but suffers from 25 poor spatial resolution and is sensitive to artefacts from non-neuronal sources of electrical activity, 1 especially muscles during participant movement (Muthukumaraswamy, 2013) . 2 Magnetoencephalography (MEG) measures the magnetic fields generated by neuronal 3 currents (Cohen, 1968) , providing direct assessment of electrophysiology. Unlike EEG, MEG has high 4 spatial precision (Baillet, 2017; Hämäläinen et al., 1993) and lower sensitivity to non-neuronal artefact 5 (Boto et al., 2019) . However, MEG systems use cryogenically cooled superconducting quantum 6 interference devices (SQUIDs) (Cohen, 1972) housed in magnetically shielded rooms (MSRs) to gain 7 sufficient sensitivity to measure the neuromagnetic field. Low temperatures mean sensors are 8 positioned in a fixed array, 2 -3 cm from the scalp (to provide thermal insulation). So, like MRI scanners, 9 MEG systems are cumbersome and static; only one person can be scanned at once, participants must 10 remain motionless, and performance is limited by sensor proximity. Nevertheless, the potential for 11 hyperscanning has been demonstrated using two MEG systems sited in the same MSR (Hirata et al., In sum, hyperscanning experiments can be carried out with existing technology, and such 16 studies are beginning to provide unique insights into how the human brain mediates social interaction 17 (Czeszumski et al., 2020) . However, current instrumentation is limited either by its performance 18 (EEG/fNIRS) or the unnatural scanning environment it provides (MEG/fMRI). The development of new 19 technology which can scan two people during live naturalistic interaction, and provide high 20 spatiotemporal resolution, artefact free, data could transform this field. 21 Recently, 'wearable' MEG has been developed through the use of optically pumped 22 magnetometers (OPMs) (Boto et al., 2018) . OPMs are sensitive magnetic field sensors that do not 23 require cryogenics. These devices have enabled the design of flexible MEG sensor arrays which can be 24 placed closer to the scalp, and adapted to the requirements of individual studies and participants. 25 achieved using cryogenic MEG (Boto et al., 2016; Iivanainen et al., 2017) . In addition, the lightweight 1 1 Figure 1 : OPM-MEG data collected during a two-person naturalistic touching experiment. a) Two participants 2 stood either side of a table. In odd numbered trials, participant 1 strokes the right hand of participant 2, with 3 their right hand. In even numbered trials, the roles are reversed. b) Beamformer images show the spatial 4 signature of beta band modulation (thresholded to 80% of the maximum value). The odd trials (participant 1 5 active) are shown in red and the even trials (participant 2 active) are shown in blue. The spatial pattern suggests 6 activity in the sensorimotor regions. (Note there is a large overlap so the blue overlay is partially obscured). c) 7 Timecourse showing the trial averaged envelope of beta oscillations, extracted from left sensorimotor cortex 8 (peak in the beamformer images). Data from participants 1 and 2 are shown in the top and bottom rows 9 respectively. In both cases, the red trace shows data recorded when participant 1 was touching participant 2. The blue trace shows data recorded when participant 2 was touching participant 1. d) Time-frequency spectra 11 of activity in left sensorimotor cortex. Data were recorded when participant 1 was active. Upper plot shows data 12 from participant 1, lower plot shows data from participant 2. The black dashed lines show the beta band. e) 13 Equivalent to (d) but data shown for when participant 2 was active. Photographs are of the authors. repeated 30 times (60 trials total) with an inter-trial interval of 5 seconds. The movements of the two 1 OPM-MEG helmets were tracked using an optical tracking system. 2 We hypothesised that beta band (13 -30 Hz) modulation, as a result of the motor control or 3 sensory response, would be observable in the primary sensorimotor regions. To test this, a beamformer 4 approach (Vrba and Robinson, 2001) tuned to the beta band, was used to derive images of oscillatory 5 modulation during the task. We also performed time-frequency analysis to show modulation of neural 6 oscillations at the location of maximum beta modulation. Figure 1b shows beamformer images 7 contrasting the task (0.5 s < t < 2 s) and control (3 s < t < 4.5 s) time windows. Figures 1c-e show the 8 temporal dynamics of oscillatory power at the peak voxel location. Despite the large head movements 9 which participants made as they reached across the table (maximum translations from the starting 10 position in any one trial were 16 mm and 24 mm, for participants 1 and 2 respectively, the maximum 11 rotations were 3.0 and 7.9 -see supplementary material) the expected task induced reduction in beta 12 amplitude was observed. In each case, the active participant (i.e. the one performing the touch) showed 13 a reduction in beta power that commenced earlier and persisted longer than that seen in the passive 14 participant. This experiment demonstrates that high-quality OPM-MEG hyperscanning data can be 15 obtained using our system, even in the presence of movements. 16 17 Two-person ball game 18 To further demonstrate the system's capabilities, we aimed to show that OPM- MEG 19 hyperscanning can be used to measure brain activity whilst two players hit a table-tennis ball back and 20 forth to one another. Unlike our guided touch task, which where we expected temporally smooth head 21 movements, we expected this task to generate movements that were quicker and more unpredictable. Despite such movement (maximum translations from the starting position in any one trial were 50.0 23 mm and 64.8 mm, for participants 1 and 2 respectively, the maximum rotations were 17.0 and 17.4) 24 we hypothesised that the matrix coil system would reduce the remnant field sufficiently to enable 25 collection of useful data; we expected to observe a decrease in beta power in left motor cortices during 1 the task. 2 The experimental setup is shown in Figure 2a . Participant 1 (see above) and Participant 3 (male, 3 right-handed, age 41, height 188 cm) undertook this experiment. The participants stood ~80 cm apart, 4 each holding a table-tennis bat in their right hand. The remnant magnetic field was nulled using the 5 matrix coil system at the locations of both helmets. An audio cue signalled the participants to begin 6 playing the game, after 5 seconds a second cue signalled the participants to stop the rally and rest for 7 7 seconds. This process was repeated 25 times and movement of the helmets during the experiment 8 was recorded. Data were processed using a beamformer to derive an image showing the spatial 9 signature of beta modulation between task (2 s < t < 4 s) and control (10 s < t < 12 s) windows. A time 10 frequency spectrum was also extracted from the peak of the beamformer image. Figure 2b shows the 11 beamformer images overlaid on an anatomical MRI. The spatial signature suggests activation in the 12 motor cortex as expected. Figure 2c shows the time-frequency dynamics of oscillatory power, revealing 13 a reduction in the amplitude of beta activity during the task. In addition to overall beta modulation (i.e. 14 the difference between playing the game and resting) we also expected that, following each strike of 15 the ball, a small amplitude increase in beta power should occur; assuming consistent timings, we 16 expected this effect should alternate between participants (e.g. we expect a peak in activity for 17 participant 1, and a trough in participant 2 just after participant 1 has hit the ball). Analysis was 18 performed to probe the presence of this relationship. Figure 2d shows beta envelopes from both 19 participants; data in the 3 s to 6.5 s time window were extracted and are shown inset in Figure 2e with their cross-correlation (yellow) reveals anticorrelation with a lag of ~0.6 s between the participants' brain activity. Photographs are of the authors. 1 OPM-MEG hyperscanning was made possible by our matrix coil, which acts to reduce the 2 strength and spatial variation of the magnetic field surrounding the OPM arrays. This is critical since, to 3 obtain the sensitivity required for MEG, OPMs must be operated at zero-field (Allred et al., 2002; 4 Happer and Tam, 1977; Savukov and Romalis, 2005) requiring sensors to be screened from all sources 5 of static and dynamic magnetic fields. This is achieved, in part, by operating inside MSRs constructed 6 from multiple layers of high magnetic permeability material (mu-metal). However, the presence of the generate an equal and opposite magnetic field to that experienced by the array, is necessary. 10 OPMs typically feature 'on-sensor' coils, which can compensate local static magnetic fields 11 experienced by the OPM, up to ±50 nT. Data are then measured relative to this offset within a narrow 12 dynamic range of around ±5 nT. However, since this compensating field is set at the start of a MEG 13 recording, any subsequent movement of an OPM with respect to the background field induces a change 14 in the measured magnetic field, which affects the data in three main ways: 15 1) In the worst case, a field shift >5 nT will saturate sensor outputs so that no data can be 2) Even if field shifts are smaller than the dynamic range, the accuracy of measured data is 18 affected by a change in sensor gain; such changes can be as large as 5% for a 1.5 nT field 19 offset (Boto et al., 2018) ; this nonlinearity causes a significant degradation of data fidelity. 20 3) Even in cases where a change in field does not cause appreciable modulation of sensor 21 gain, the artefacts caused by rotating the sensor in a field, or translating it in a field 22 gradient, can mask brain activity (e.g. in a 5 nT field, a rotation of just 1 would cause an 23 artefact of ~90 pT, which is ~100 times larger than a typical evoked signal at the scalp (Boto 24 et al., 2017)). 25 For these reasons, creating a zero magnetic field environment is crucial for enabling OPM operation. To address these issues, we developed a system of matrix coils, comprising two 1.6 x 1.6 m 2 1 planes, each containing 24, individually controllable, square coils. Each coil has a square side length of 2 38 cm and is formed of 10 turns of copper wire. A regular 4 x 4 grid of these coils is wound onto each 3 plane along with an overlapping (to allow finer field control in off-axis directions) 3 x 3 grid of coils 4 (excluding the central coil), as shown in Figure 3a . The coil planes were separated by 150 cm and 5 positioned such that the centre of the coil array was at a height of 130 cm from the floor, with the array 6 spanning a height range of 50 to 210 cm. By measuring the remnant magnetic field inside the MSR 7 experienced by each OPM (projected along its sensitive axes) in the helmet, along with a calibration 8 matrix containing the magnetic field generated per unit current, at each OPM, by each of the 48 matrix 9 coils, we can compute the coil currents that will optimally null the magnetic field experienced by the 10 array. This data-driven approach is easily extended to two separate arrays, and provides a low field 11 environment for OPM-MEG experiments which can be readily adapted to the requirements of different 12 paradigms. Participants are required to remain still during the nulling process, but the nulled volumes 13 can be placed at any location between the coils, meaning that an experiment can be carried-out with a 14 single participant standing or seated, or with multiple participants. 15 To demonstrate the effectiveness of the coils, the two-person experiments, described above, 16 were repeated without the coils activated. We expected that the strength and spatial variation of the 17 magnetic field over the helmet would increase when the coils were switched off, such that the artefacts 18 generated by movements would obfuscate the neural response. 1 The matrix coil system and its effects on the background magnetic field and data quality. a) The 48-coil bi-planar matrix coil system. The current in each coil is individually controlled to 2 generate the required field in order to cancel the remnant magnetic field inside the MSR. The current distribution shown was used during the two-person ball game. b) The strength of the DC 3 field, reported by the 48 total field measurements from 24 OPMs (12 per participant), with and without the matrix coils active, during the two-person touch task. The error bars show standard participant 2. During the two-person ball game the field decreased from 3.8 ± 2.8 nT to 1.6 ± 1.3 nT (a 1 factor of 2.4) for participant 1 and from 5.7 ± 2.9 nT to 2.0 ± 1.2 nT (a factor of 2.9) for participant 3. when the matrix coils were inactive and panel e shows equivalent data, from the same sensor, when 6 the matrix coil system was used. with the system inactive, large positive changes from baseline spectral 7 density extend across the alpha and beta bands. However, these become negative changes (reflecting 8 the genuine task induced response) when the coil is activated. This degradation is caused by 9 movements of the array through the non-zero remnant field. When activated, the matrix coil reduces 10 the size of the artefacts, revealing the expected response. Figure 3f shows a comparison of the 11 percentage change from baseline of measured oscillatory amplitude, in six key frequency bands, during 12 the task (0.5 to 2 seconds). Mean values are shown, and error bars represent standard error over trials. 13 Most strikingly, alpha desynchronisation is masked when the matrix coil system is not active. These Solo demonstrations 18 To further demonstrate the effectiveness of the matrix coil system we conducted a series of 19 ball-game experiments on a single participant (participant 2). 37 OPMs were spread over the helmet to 20 obtain whole-head coverage. On receipt of an audio cue, the participant was instructed to bounce the 21 table-tennis ball on the bat for 10 seconds, until a second audio cue instructed them to rest for 5 22 seconds. This process was repeated 40 times. The experiment was repeated with and without the 23 shows the degree of DC magnetic field cancellation achieved at each position. (iv) shows the task 6 induced (percentage) change from baseline of oscillatory amplitude in six key frequency bands in data 7 from a single sensor sited over the left motor cortex. These indicate that the alpha band modulation 8 was again obscured without field nulling. We also note the consistency of the field nulling and artefact 9 reduction achieved at each of the three helmet locations. 10 Brain stimulation in functional imaging is often provided by artificial controlled events, which 12 take place in restrictive, claustrophobic environments. Whilst useful, such experiments are of limited 13 utility for understanding of how the human brain works in its native surroundings. Multi-modal stimuli, 14 such as audio-visual footage and immersive (real or virtual) environments are now routinely deployed 15 to investigate brain function during spontaneous, interactive events which more closely mimic real-life. 16 Such naturalistic settings are crucial for collecting ecologically valid neuroscientific data; indeed it has 17 been postulated that the evolution of the human brain is closely linked to a need for complex social 18 interactions (Dunbar, 1998) . For this reason, the importance of developing neuroimaging platforms that 19 can interrogate brain function in naturalistic settings, is paramount. To date, the necessary technology 20 to image brain function has been lacking either in performance or viability. Our work, for the first time, 21 introduces a hyperscanning platform capable of direct detection of electrophysiological responses, with 22 millisecond temporal and millimetre spatial precision, during natural, live interactions. the relative timings of responses across participants. The second critical element of our system is the 7 matrix coil system, which produces the zero-field environment in which the OPMs must be operated. 8 The zero magnetic field requirement of OPMs is a significant barrier to producing wearable MEG 9 systems which tolerate movement. OPMs have a low dynamic range and movement (even in an OPM-10 optimised MSR with a remnant field of a few nT) can render them inoperable. In addition, a changing 11 field at the sensor induced by participant motion can generate marked changes in OPM sensor gain. 12 Most importantly, movement generates large artefacts which obscure the neuromagnetic field. The 13 use of the matrix coil ensured that OPMs remained operational and minimised gain changes in 14 experiments. Further, motion induced artefacts were minimised; to an extent that, in the absence of 15 matrix coil nulling, the expected alpha event related desynchronisation was completely masked by 16 movement artefact -but recovered with the coil activated. 17 To demonstrate the adaptability of the matrix coil, we also performed single-person OPM-MEG 18 recordings of a participant standing, seated on a chair and seated on the floor. The robustness of the 19 spatial signature and temporal dynamics of the reconstructed neuronal activity highlights the utility of 20 the system. It is significant that traditional Helmholtz or bi-planar coil designs are formed from fixed 21 current paths which generate a known magnetic field within a prespecified volume. Such a design 22 enables participant head movement within that volume but does not allow the nulled volume to be 23 moved around the MSR. The matrix approach allows the coil to 're-design itself', altering the current 24 distribution in response to the location of the participant. This allows participants to be positioned 25 anywhere between the coils, and even facilitates the creation of two separate nulled volumes, which is essential for hyperscanning. The modular nature of the matrix coil system also makes its design and 1 construction simple compared to winding the intricate wire paths required by distributed coils systems: 2 complexity is shifted to the coil amplifier and field control systems. Importantly, the data-driven field 3 cancellation approach accounts for any helmet position, coil layout and the magnetic field distortions 4 due to the presence of mu-metal, readily adapting to any size or shape of MSR. 5 There are some limitations of the present system to consider. Results showed that the 6 performance of the matrix coil system during the two-person ball game was not as good as that during 7 the guided touch or individual person paradigms. This is due to the increased separation of the two 8 participants (required to hit the ball) which pushed the helmets worn by the participants to the edges 9 of the coil planes. Consequently, fewer unit coils were available to contribute to the nulling and so Ultimately, a true understanding of the brain, and the many disorders that affect it, will only 8 come through the ability to assess naturalistic function. Social interaction is a cornerstone of human 9 development, and so understanding brain function during naturalistic interaction is a critical step along 10 this path. OPM-MEG technology offers a means to do this, with an adaptable scanner equally able to 11 scan one person or two people, using the same instrumentation, providing high fidelity measurements 12 of brain activity. OPM-MEG using matrix coil technology thus has the potential to become the method 13 of choice for future multi-person neuroimaging studies. Texas, USA). Since all the OPMs are sampled and controlled using the same equipment, no additional timing signals or hardware are required to synchronise the data collected from the two helmets. 1 Participant movements were tracked using a OptiTrack V120:Duo (NaturalPoint Inc., Corvalis, USA) 2 optical tracking system which provides sub-1-millimetre and sub-1-degree precision optical tracking of 3 multiple rigid bodies at a sample rate of 120 Hz. Two cameras, each with an array of 15 infrared (IR) 4 LEDs, are used to illuminate IR reflective markers and the combined coordinates of multiple markers 5 are used to form a rigid body tracking with 6 degrees of freedom (x, y and z translations, pitch, yaw and 6 roll rotations). 7 8 Matrix coils 9 Our aim was to develop a system that produces a magnetic field, equal in magnitude but Each unit coil is connected to a single output of a 48-channel, low-noise, voltage amplifier that 23 was designed and constructed in-house. This is interfaced to three NI-9264 16-bit, digital to analogue 24 converters (DACs) that are controlled using LabVIEW. The voltages applied at the amplifier input range 25 between ±10 V (least significant bit (lsb) voltage = 20 V/2 16 = 0.305 mV). The maximum electrical current in the coil is tuned by an additional series resistance, which in this setup was 1.2 kΩ, chosen such that 1 the magnetic field noise generated by the coils was beneath the noise floor of the OPMs. The coil driver 2 current noise at this resistance is <10 nA/√Hz in the 1-100 Hz band, we estimate this translates to <20 3 fT/√Hz noise in the field from all 48 coils at the centre of the planes (see supplementary material), for 4 comparison, the OPM noise floor is <10 fT/√Hz in this frequency range so the two are comparable. The 5 maximum current which can be applied to each coil is ±8.33 mA, and the lsb current is 2.54 µA. 6 To null the remnant magnetic field inside the MSR during a MEG experiment we employed a 7 data-driven approach. If the magnetic field measured by the th OPM in an array of sensors due to 8 unit current in the th coil in a set of (= 48) matrix coils is written as ⁄ , we can form a ( x 9 ) coil calibration matrix, , from the full set of values. The field nulling problem can then be described 10 using the following matrix equation: 11 where the ( x 1) column vector contains the currents applied to each coil and the ( x 1) column 14 vector characterises the magnetic field to be cancelled. is formed using the DC field values 15 measured at the sensors, the negative sign is used to ensure the calculated currents null the magnetic 16 field measured by the array. 17 The coil currents required to minimise the sum of squares of the measured magnetic field 18 values can be found by identifying the negative of the Moore-Penrose pseudo-inverse matrix of , 19 To minimise the power dissipated by the system, and ensure the solution is physically realisable, the 21 matrix can be regularised prior to inversion by addition of a matrix where is the identity matrix 22 of the same dimensions as and is a regularisation parameter i.e. 23 To keep the coil currents within the allowed bounds, equation [4] is cast as a feed-forward controller: 2 coil currents are incrementally updated, based on the OPM field measurements at each timepoint , 3 and the currents applied at the preceding time point as 4 The gain coefficient is empirically set to produce a stable reduction of the measured fields towards 6 zero on a timescale of a few seconds. 7 This approach can readily be adapted to changes in the number and shape of the unit coils and parameter (in Eq. [5] ) was set to 1% of the maximum singular value of the matrix . The feed-23 forward controller gain was set to 0.1 with a time step of 100 ms. The time needed for the calibration process scales with the number of coils and takes around 25 experiments, i.e. no dynamic tracking of changes in magnetic field was applied (we note the magnetic 1 field drift in our MSR is on the order of 200 pT over 10 minutes). The LabVIEW program stores the 2 magnetic field values reported by each sensor prior to calibration, along with the coil calibration matrix, 3 the final voltages applied to each coil and the final magnetic field values. During the two-person ball game experiment, participant 1 again wore an individualised 17 scanner cast, whilst participant 3 (and male, aged 41, height 188 cm) wore a generic 3D printed helmet 18 (co-registration as above). The participants were instructed to hit a table-tennis ball back and forth to each other for 5 seconds, following an audio cue. A second audio cue instructed the participants to stop 1 their rally and rest for 7 seconds. This was repeated 25 times. Movement of the two helmets was again 2 tracked using the OptiTrack camera system throughout the experiment. Each Hyperscanning task was 3 repeated twice, with and without the matrix coils active (the participants were not blinded to this 4 condition). Trials where the ball was dropped were noted and excluded from data analysis (two dropped 5 balls in each condition). 6 For the solo MEG experiments, a single participant (participant 2) wore the generic scanner-8 cast containing 37 OPMs distributed over the entire head. During the experiment, the participant was 9 instructed to bounce a table-tennis ball on the bat for 10 seconds following an audio cue. A second 10 audio cue instructed the participants to stop and rest for 5 seconds. This was repeated 40 times. 11 Recordings were made while the participant stood up at the centre of the coil planes, then sat 12 on a chair and finally sat on the floor of the MSR. The entire process was repeated with and without 13 the matrix coils active. All trials were complete successfully without dropping a ball. 14 In the hyperscanning experiments, measurements of the amplitude of two field components 16 from 10 OPMs operating in field zeroing mode housed in the scanner-casts of each participant (i.e. the 17 matrix contains values from 20 OPMs giving = 40 measurements in total) were used as inputs to 18 the LabVIEW-based field nulling program described above. The 10 sensors on each helmet that were 19 used for the nulling process, included the additional sensors sited at the front, back and right-hand 20 sides of the head, as well as seven sensors sited over the left side of the head. Participants were asked 21 to remain still whilst the system was calibrated and instructed to keep their feet planted throughout 22 the experiment to avoid translating their heads away from the nulled volume. 23 During the solo experiments, The two field components measured by 12 OPMs ( = 24 total 24 measurements) operating in field zeroing mode were used as inputs to the field nulling program. Field nulling sensors were chosen such that they spanned the full volume of the head and are highlighted in 1 Figure 6 . 2 All OPM data were collected at a sample rate of 1,200 Hz using the equipment described earlier. 4 Once the matrix coil currents had been set, the OPMs were field zeroed and calibrated using the QuSpin 5 software. The OPMs were then set to their 0.33x gain mode (voltage to magnetic field conversion factor 6 0.9 V/nT) in which their dynamic range is ±5 nT. The default gain setting has a lower dynamic range of 7 ±1.5 nT (2.7 V/nT) which was not used here as the outputs would have quickly saturated when 8 participants moved during the nulling-off experiments. 9 10 Data analysis 11 All code for analysis was custom written by the authors using MATLAB. 12 A beamformer approach was used to generate the images shown in Figures 1, 2 where is the forward field vector containing the solutions to the MEG forward problem for a unit 21 dipole at . The optimal weights vector is expressed as 22 where is the sensor data covariance matrix. Inversion of the covariance matrix is aided by Tikhonov 24 regularisation (i.e. by addition of the identity matrix scaled by regularisation parameter ). To compute the weights vectors for each experiment, the entire dataset was filtered to the 1 beta band (13) (14) (15) (16) (17) (18) (19) (20) (21) (22) (23) (24) (25) (26) (27) (28) (29) (30) and used to compute the covariance matrix. The regularisation parameter was 2 set to 0.01 times the leading singular value of the covariance matrix. The forward field vector was 3 calculated using a multi-sphere head model and the current dipole approximation (Sarvas, 1987) . 4 Images of activation show the pseudo-T-statistical contrast between data recorded in active 5 and control windows. Specifically, two covariance matrices were computed for the active and control 6 periods, and respectively, and the pseudo-T-statistical contrast, at , calculated as 7 Ŧ = − 2 . [9] 8 Pseudo-T-statistics were computed at the vertices of a regular 4 mm grid spanning the whole brain. 9 This grid of Ŧ values was then thresholded to a percentage of the maximum value and overlaid onto 10 the anatomical MRI of each participant. In the touch experiment the Ŧ values were thresholded to 80% 11 of the maximum value for each condition. The active period was 0.5 to 2 seconds and the control period 12 was 3 to 4.5 seconds. In the two-person ball game the active period was 2 to 4 seconds and the control 13 period was 10 to 12 seconds. In the single-person ball game the Ŧ values were thresholded to 70% of 14 the maximum value, the active period was 2 to 4 seconds and the control period was 8 to 10 seconds. 15 For each experiment, the location of the voxel with largest pseudo-T-statistic was determined 16 for each participant. The signal from this peak location was reconstructed to form a 'virtual electrode' 17 timecourse (using Equation 6), with beamformer weights calculated in the broad-band (1-150 Hz). 18 The time-frequency spectra were generated by filtering this timecourse sequentially into 19 overlapping frequency bands. For each band, the Hilbert envelope was calculated before segmenting 20 and averaging over trials and concatenating in the frequency domain. The mean envelope in the beta 21 band was computed using the virtual electrode timecourse filtered to the beta band (13-30 Hz). 22 Similar analysis was performed to generate the sensor level time-frequency spectra shown in 24 Figure 3d and 3e. The bar charts comparing change from baseline activity in Figure 3f and 4abc (iv) were computed using contrasting active and control periods, as above, and non-overlapping frequency 1 bands. 2 Correlation of brain activity (Figure 2e ) was computed using the 3-6.5 s window of the beta 4 band filtered virtual electrode average trial timecourse. The normalised, unbiased, autocorrelation and 5 cross-correlation of the two timecourses were computed for a maximum lag of 3.5 s (i.e. the full 6 duration of the data segment). 7 8 Acknowledgements: We express our sincere thanks to collaborators at the Wellcome Centre for Human 9 Neuroimaging, University College London, UK for extremely helpful discussions and ongoing support. Supplementary material 5 6 1. Motion during experiments 7 To assess the range of movements during the experiments and their comparability we further 8 analysed the data recorded by the OptiTrack camera system. The helmet translation (x, y and z, defined 9 relative to the camera position) and rotation (pitch roll and yaw, defined as rotation about the centre 10 of mass of the rigid body which is formed from four infrared reflective markers placed onto the front 11 or back of the helmet worn by the participant, depending on the field-of-view of the camera) data were 12 segmented into trials. The first data point was subtracted from each trial such that the motion data 13 reflected the change in translation or rotation of the rigid body on the helmet relative to its initial 14 position during a trial. All six motion parameters are plotted in Figures S1-S7 for each experiment, for 15 each trial and with and without field nulling to show the range of motions required in each task and 16 comparability of these motions across conditions. As the magnetic field generated by each of the 48 coils in the matrix coil will sum, careful 2 consideration of the magnetic field noise induced by current noise in the system is required. A balance 3 is needed between the maximum current which can be produced in order to generate the required 4 magnetic field profiles, and field noise induced by the amplifier electronics that could mask brain 5 activity. 6 The voltage across the 1.2 kΩ resistor in series with each coil with the voltage amplifiers active 7 was recorded and converted to current. The current noise measured was <10 nA/√Hz in the 1-100 Hz 8 band. We simulated the magnetic field (taking into account interactions between the magnetic fields 9 generated by the coils and the high-permeability material used to construct the MSR) for 10 nA of 10 current in each coil at each point in a regular 10-cm resolution grid spanning a 1.4 x 1.4 x 1.4 m 3 volume 11 between the matrix coil planes as shown in Figure S8 . For each vector component of the magnetic field 12 at each point in the grid we computed the square root of the sum of the squared magnetic field values 13 for each coil as an estimate of the noise in each direction. The square root of the sum of these squared 14 vector values was then taken as an estimate of the magnitude of the noise. Each noise estimate is 15 expressed in units of fT/√Hz. 16 Figures S9-S12 show maps of the spatial variation of the magnetic field over the volume 17 between the coil panels. The noise at the centre of the coil planes is <20 fT/√Hz in each direction which 18 is comparable to the OPM sensitivity. The strength of the magnetic field noise increases as proximity to 19 the coils increases. Unaffected by Spin-Exchange Relaxation Minimizing magnetic fields for precision 6 experiments MEG 8 dual scanning: A procedure to study real-time auditory interaction between two persons Magnetoencephalography for brain electrophysiology and imaging Imaging the human hippocampus with optically-pumped 14 magnetoencephalography Non-invasive functional-brain-imaging with an OPM-based magnetoencephalography 17 system On the 19 potential of a new generation of magnetometers for MEG: A beamformer simulation study Measuring functional connectivity with wearable MEG 25 towards real-world applications with a wearable system A new generation of magnetoencephalography: Room 4 temperature measurements using optically-pumped magnetometers Wearable neuroimaging: Combining and 8 contrasting magnetoencephalography and electroencephalography Magnetoencephalography: Detection of the brain's electrical activity with a 11 superconducting magnetometer. Science (80-) Magnetoencephalography: Evidence of magnetic fields produced by alpha-rhythm 13 currents. Science (80-) Rendon 15 ZZ, König P. 2020. Hyperscanning: A Valid Method to Study Neural Inter-brain Underpinnings of Brain-to-Brain Synchrony Tracks Real-World Dynamic Group 19 Interactions in the Classroom The social brain hypothesis Detection of very weak magnetic fields 23 (10−9gauss) by 87Rb zero-field level crossing resonances Balanced, bi-planar magnetic field and field gradient coils for field 2 compensation in wearable magnetoencephalography Measuring MEG closer to the brain: Performance of on-5 scalp sensor arrays On-scalp MEG system utilizing an 7 actively shielded array of optically-pumped magnetometers Dynamic multi-coil 10 shimming of the human brain at 7 T Magnetic field modeling with a set of 12 individual localized coils Dynamic multi-coil technique 14 (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla Getting to know you: 17 Reputation and trust in a two-person economic exchange Decoupled circular-polarized dual-head volume coil pair for studying two 20 interacting human brains with dyadic fMRI Speaker gaze increases information 22 coupling between infant and adult brains Perception of social synchrony induces mother-child gamma 25 coupling in the social brain The integration of social and neural synchrony: A 1 case for ecologically valid research using MEG neuroimaging Using optically-pumped magnetometers to measure magnetoencephalographic 5 signals in the human cerebellum EEG and MEG: Relevance to neuroscience Hyperscanning: Simultaneous fMRI during linked social interactions High-frequency brain activity and muscle artifacts in MEG/EEG: A 12 review and recommendations Brain-to-brain synchrony in parent-child dyads and the 14 relationship with emotion regulation revealed by fNIRS-based hyperscanning With Two-Person Dual-Coil fMRI Towards OPM-MEG in 20 a virtual reality environment Basic mathematical and electromagnetic concepts of the biomagnetic inverse 22 problem Effects of spin-exchange collisions in a high-density alkali-metal vapor 24 in low magnetic fields Fully integrated, standalone zero field optically pumped 1 magnetometer for biomagnetism. Steep Dispers Eng Opto-Atomic Precis Metrol XI 51 A compact, high performance atomic magnetometer for biomedical 4 applications Optically pumped magnetometers: From quantum origins to multi-7 channel magnetoencephalography Cognitive neuroscience using 10 wearable magnetometer arrays: Non-invasive assessment of language function Mouth magnetoencephalography: A unique perspective on the human 15 hippocampus Optically pumped 18 magnetoencephalography in epilepsy Measures to reduce the 21 residual field and field gradient inside a magnetically shielded room by a factor of more than 10 Signal processing in magnetoencephalography