key: cord-0326957-ya7e2ogy authors: Mogos, A. Samson; Grillo, Samuele title: Impact of EV Charging Stations in Power Grids in Italy and its Mitigation Mechanisms date: 2021-02-15 journal: nan DOI: 10.1109/eeeic/icpseurope51590.2021.9584782 sha: 4300de7c8db9e5b32ed8049bee5374abca6d1426 doc_id: 326957 cord_uid: ya7e2ogy Global warming leads the world to think of a different way of transportation: avoiding internal combustion engines and electrifying the transportation sector. With a high penetration of electric vehicle (EV) charging stations on an existing power distribution network, the impact may be consistent. The loads of the fast-charging stations would potentially result in increased peak load demand, reduced reserve margins, voltage instability, and reliability problems. The degrading performance of the power system due to the negative impact of the EV charging stations can even lead to penalties to be paid by the distribution system operator (DSO). This paper: i) investigates the impact of the ac{ev} charging station on the distribution network for what concerns voltage drop on MV feeders and loading of transformers in primary substations, and ii) proposes a mitigation mechanism. A realistic typical Italian grid has been used to assess the impact of EV charging stations and to validate the mitigation mechanism. The increasing demand for electricity and the dependence of the energy source on a non-renewable finite fossil fuel supply, accompanied by the impact of pollution on global warming and drastic climate changes, are the key concerns of this era's environmental researchers. In the transportation sector, nowadays, most of the vehicles are emitting CO 2 which is considered as the main cause for global warming and climate change [1] , [2] . Most researchers are been engaged in the research of the positive impacts of avoiding internal combustion engine (ICE) driven vehicles and replacing them with electric vehicles (EVs) to minimize the carbon emission and protect the climate change and global warming. It is indeed a good idea to shift from conventional vehicles to EVs as it has many environmental and economic advantages [3] . For this reason, EVs are becoming more popular in the market. However, the increasing number of EVs is creating a rise in charging load demand. For example, in the USA, the National Program Charging Point America has started to build about 5000 EV charging stations in nine regions of the country [4] . As per 2020 PHEVs sales data in Europe, it was shown 210% increase compared to 2019. There was no potential negative effect on the increase of EV deployment due to COVID-19 [5] . It can be easily understood that the world is more aware of global warming and climate change, but not on the impact of EV charging stations on the already built power grids. The installation of EV charging stations becomes an additional load burden on the power grids. High EV charging loads, especially by fast EV charging stations, will decrease the quality of the power system operating parameters on the power distribution grids. The quality of voltage profile will decrease with an increase in the peak load, power system equipment like transformers and power lines will be overloaded during peak hours-which will lead to early aging-, and harmonic distortion is a consequences of the uncoordinated charging of EVs. Some researchers have dealt with the impact of EV charging loads on different parameters of power system networks like voltage profile [6] , harmonics [7] and peak load [8] . One of the potential impacts is the degradation of the voltage profile. In [6] authors analyze this issue on a low voltage distribution network in Europe for different EV penetration scenarios. They have concluded that the existing network is strong enough to support a low intake of EVs (i.e., from 1% to 2%). It was also concluded that there was a considerable voltage drop on the load nodes where there are many charging stations installed. In [9] , authors analyze the impact on a 13-bus distribution network for different EV penetration scenarios. They have concluded that the transient voltage stability index degraded for high penetration of EVs. Similarly, in [10] , the impact of large EV charging load penetration on voltage stability on the power distribution network is conducted, concluding that most of the existing power distribution networks can tolerate an EV charging load penetration only for a limited level. They both conclude that, having been the networks designed and planned some years ago and assuming that the electric load demand will increase in the coming years, they are inadequate and they are unlikely to withstand high EV charging load penetration. Either an enhancement of power system equipment or a replanning will be required to address this issue. Researchers in [11] , [12] , have studied that EV charging stations supported by renewable energy have the ability to meet the increasing EVs power demand and have the potential to mitigate their impact in power grids. Authors in [13] have designed a control strategy to utilize different energy sources to minimize the grid congestion due to EVs charging load. Most of the previously conducted studies are focused mainly on impacts of EV charging station loads such as voltage instability, harmonic distortion, and power losses on the distribution network. Furthermore, most of the studies were conducted on test networks. Very few scholars have performed their research on a real built-in power distribution network. Considering the aforementioned statements this paper is conducted on a realistic and typical power distribution network of the industrial belt of a large Italian city. Some of the major contributions of the study are the following: • A brief analysis of the impact of the EV charging station loads on the voltage stability (maximum voltage variation) of the distribution network. • Detailed analysis of the impact of the EV charging station loads on the power system elements loading and peak load. • Forecasted analysis of the EV charging load on different parameters of the distribution network such as the voltage stability, peak load, and equipment loading, at the years of 2020, 2023, 2025, 2026 and 2030. • Applying the mitigation mechanism and evaluating the grid characteristics. The paper is organized as follows. In Section II the grid under study is described. In Section III the different case studies used for analyzing the impact of EV charge load and testing the effectiveness of the proposed mitigation mechanisms. Section IV is devoted to the simulation of the results. Finally, conclusions are drawn in Section V. The grid under study mimics a realistic and typical distribution network in Italy. Moreover, it could be also representative of a more general European distribution system. Primary substations, especially when serving an industrial zone, have multiple busbars feeding several MV portions of the distribution system. In the present study, only one busbar from the main substation is considered. It is composed of 7 MV lines, one 40 MV A HV/LV transformer, 38 MV customers with total installed power of 27.7 MW, distributed generators summing up to 5.4 MW nominal active power and connected to the MV lines, approximately 10,000 LV customers, and 138 secondary substations. The nominal voltage of the HV system is 132 kV and the distribution voltage level are 15 kV. Power transformers are with different power rating ranging from 63 kV A to 630 kV A. All the transformers are step-down transformers from 15 kV to 0.4 kV, with the obvious exception of the substation transformer (132/15.6 kV) and of the step-up generator transformers (0.4/15 kV). A piece of summarized quantitative information could be found in the Tables I-IV. The distribution branches are overhead or underground cables. In total, there are 178 branch lines with a crosssectional area ranging from 20 mm 2 to 240 mm 2 . The types of branches are aluminum (AL), aluminum alloy (AC), and copper (CU). Cooling The power factor of all the solar PV generators is considered to be 1, while it is either 0.8 or 0.9 for the dynamic generators. A summarized quantitative data of the generators could be found in Table IV. The MV clients that are connected to this grid are mainly industries. The total installed power of the MV customers is 27.7 MV A. Some of the MV clients are not only consumers but also generators. Thirteen out of the 38 MV customers sum up to a total of 13.3 MW installed nominal power and they produce up to 5.4 MW in total. In this study, the average load profile of the MV customers is considered. The load profile was calculated based on a real-time measurements provided by the DSO of the months of February, May, July, and November. The load profile was taken every 15 min in a day for a full month. Figure 1(a) shows the average MV per unit load profiles. The load measured in February has been taken as "winter load", while the one in July as "summer load". There are more than 10,000 LV customer connected to the network by means of 153 MV/LV transformers in the secondary substations. All LV customers under the same secondary substation have been gathered in one single equivalent three-phase load. For the ease of the study, the LV and MV loads are considered as a balanced load. The average LV load profile considered are reported in Fig. 1(b) . The following case studies are conducted to investigate the impacts of EV load on the power grid. Two types of EV loads are considered, the ones connected to chargers on households and the ones connected to a park & ride (P&R) facility. In this study two cars per household (LV customer) is considered [14] . Although not all EV charging stations have power factor corrector, most of them operate at a unity power factor unless they are used for reactive power compensation. In this paper all EV charging loads are considered to have a unity power factor. In the following four case studies, the effect of different EV load penetration levels on the performance of power distribution grid, i.e., voltage profile deviation, percentage of loading of the main transformer, and peak to average ratio (PAR), are assessed. The EV load penetration considered on this paper are according [14] . This is a single year study for the year of 2020. Penetration levels of 11% (low), 35% (medium), and 45% (high) are considered [14] . In this case only the EV loads of households are considered. In this case, three definite years are selected to probe the impacts of medium EV penetration level for the year of 2020, 2023 and 2026. • The year 2020: EV penetration level is 35% and the LV load profiles reported on Figures 3 and 4 are considered for each household. • The year 2023: EV penetration level is 47% and other load profiles show a load growth of 4.9% compared to that of 2020. • The year 2026: EV penetration level is 50% and other load profiles show a load growth of 7.8% compared to that of 2020. The assumption made here is that the infrastructure of power grid remains the same, while the number of LV and MV customers increases by 1.3% each year due to the growth of population [15] , [14] and other factors like industrial growth. This case is a study conducted for 2020 with a medium household EV load penetration and an additional EV charger on a P&R facility. Three P&R facilities with 1000 parking lots each equipped with 3.3 kW EV charger is considered. This makes the total installed EV load in the P&R facilities to 9.9 MW. This case could be the most likely to happen in the future with all EV loads considered. The load growth will be considered 0.9% per year instead of 1.3%. The 0.9% load growth is the most likely values in Italy [16] . Some probable EV penetration percentages and years are taken. This case is aimed to study the long-term impact: 10% EV load penetration in 2020, 30% EV load penetration in 2025 and 50% EV load penetration in 2030. Load flow analysis was performed to calculate the total load and voltage deviation in different load points of the network using DIgSILENT Power Factory. Power flow is simulated sequentially over successive time steps using the quasi-dynamic simulation function. This Section presents the results obtained when the simulations are run for the case studies reported in Section III with unoptimized and optimized EV charger loads. It also discusses the result obtained in reducing the negative impact of EV charger loads when upgrading the main transformer. The formulation of the EV charging load and their optimization mechanism are described in [17] . The objective of the optimization is to charge EVs, keeping, during each time interval, the power drawn by the i-th EV below the maximum charging limit of a charge point and the total power of the P&R facility below the nominal power. The details of the optimization algorithm can be found in [17] . The EV load of the P&R facility is represented in Fig. 2 , with and without considering the optimization algorithm. The study is conducted in winter and summer for the year 2020. The obtained result are shown in Figures 3(a)-3(d) . Numerical results are reported in Table V . Increasing in EVs load penetration caused an increase in voltage deviation; 45% EV penetration leads to about a 1% increment in the maximum voltage deviation compared to no EV penetration. However, this deviation can likely be limited to its cap, using voltage regulators in the network. It illustrated that, during peak hours, the transformer is loaded up to 83.87% in the worst case, in winter with 45% EV penetration. The grid is ready to accept up to about 40% of EV penetration, but above that the substitution of the main transformer is necessary. The result obtained for Case II are shown in Figures 3(e)-3(h) . Numerical results are reported in Table VI. After a careful assessment, the following findings can be reported: The simulation results for this case lead to some practical considerations. Both peak load and PAR are higher in 2023 than in 2020 but do not change significantly from 2023 to 2026. The reason for this is that the growth rate of EV penetration level is higher within 2020-2023 than that of period 2023-2026 and the majority of EVs charge at the time of household peak load. Higher PAR will lead to high operation costs. As expected, the increment of EV charging stations causes an increment in the voltage deviation on the main busbar of the networks and also on each load nodes. Furthermore, the main transformer is loaded above 90% and this will create aging on the equipment. The transformer should be reinforced with an additional cost. The cost of reinforcement can be minimized by optimizing the EV loads. Generally, it can be noted that winter is the worst case both in peak power and maximum voltage deviation. The result obtained for Case III are shown in Figures 3(i)-3(l). Numerical results are reported in Table VII . The results show that a 16% increase in the peak load when there is no load optimization. This will create considerable stress on the distribution grid and its elements even if it is for a short period of time. When the load optimization mechanism is applied the peak load increment, compared to the no-EV scenario, decreases from 16% to only 6% and the stress is reduced accordingly. By optimizing the load, the PAR is reduced from 1.48 to 1.25, in winter. This has a positive impact on reducing the operational stress of the power grid. The voltage profile is always been with in the acceptable limits according to EN50160. Tables VIII-IX. The major problem found from this simulation is overloading of the main transformer. In 2030 in the winter season, the maximum loading of the transformer is 99.99%. The transformer is already saturated, and it is not safe to work at this saturation level. On the unoptimized load scenarios, the loading graphs have very sharp edge on the peak hours. This shows higher difference between the peak power and lowest power which leads to higher PAR value. In this paper, a detailed investigation of EV charge load impacts was made on distribution systems in Italy and the mitigation mechanism is discussed. To realize this study, realistic data from a grid in Italy were used. The study was performed in four different case studies with their own unique characteristics (i.e., EV load penetration, years of study and type of EV load). In order to have a more comprehensive view, the study was conducted for a summer and winter seasons. The focus has been put primarily on the impact of EV charging loads on the voltage profile, maximum voltage deviation, peak to average ratio (PAR) of active power, peak loads, and transformer loading. It was found that, as the EV load penetration increases transformer loading and PAR increase. This results in unsuitability of the distribution network to accept high EV load penetration. A slight voltage drop in the MV nodes was detected. Nevertheless, the voltage at MV nodes keeps lying within the acceptable limits. Hence, the main conclusion is that the network studied is ready, as it is, without further development, for a safe EV load penetration up to 2026. After implementation of the mitigation mechanism a considerable drop on both transformer loading and PAR was obtained, hence a better stability performance. The post COVID-19 situation could have a "positive" effect on fostering private transportation, as opposed to public transportation. More EV charge penetration is expected in the future. This gives an alert that a special attention should be given to the issue studied in this paper. Delinking indicators on regional industry development and carbon emissions: Beijing-Tianjin-Hebei economic band case Decoupling and Decomposition Analysis of Carbon Emissions from Industry: A Case Study from China Impact analysis for market uptake scenarios and policy implications Dynamic impacts of fast-charging stations for electric vehicles on active distribution networks Electric vehicle charging network in Europe: An accessibility and deployment trends analysis Modeling and simulation of electric car penetration in the distribution power system Case study A statistical analysis of the effect of electric vehicle battery charging on distribution system harmonic voltages The HV system impacts of large scale electric vehicle deployments in a metropolitan area Identification of the weakest buses in unbalanced multiphase smart grids with plug-in electric vehicle charging stations Research of voltage stability analysis method in distribution power system with plug-in electric vehicle Decentralized EV-Based Charging Optimization With Building Integrated Wind Energy Operational Planning of Electric Vehicles for Balancing Wind Power and Load Fluctuations in a Microgrid Integration of Solar PV-WECS and DG Set for EV Charging Station Investigating the impacts of plug-in hybrid electric vehicles on power distribution systems Annual Energy Outlook 2007: With Projections to 2030 Environmental Assessment of Plug-In Hybrid Electric Vehicles Charging optimization for electric vehicles in large Park & Ride areas The research leading to this paper has been partially funded by the MIUR PRIN 2017K4JZEE 006. (n) Voltage profile (summer unoptimized).(o) Voltage profile (winter optimized).(p) Voltage profile (winter unoptimized).(q) Trafo loading (summer optimized).(r) Trafo loading (summer unoptimized).(s) Trafo loading (winter optimized).(t) Trafo loading (winter unoptimized).