key: cord-0321321-pxrhxy3h authors: Motlagh Zadeh, L.; Brennan, V.; Swanepoel, D. W.; Lin, L.; Moore, D. R. title: Remote self-report and speech-in-noise measures predict clinical audiometric thresholds date: 2022-05-10 journal: nan DOI: 10.1101/2022.05.09.22274843 sha: 6bf9ef6e75ae3a793de505d486e3f13d1e7f7965 doc_id: 321321 cord_uid: pxrhxy3h The COVID-19 pandemic highlighted the need for remote, but reliable hearing tests. Previous studies used remote testing but did not directly compare results in the same listeners with standard lab testing. Digits-in-noise (DIN) is a reliable speech-in-noise test that can be self-administered remotely. This study investigated the predictive validity of a self-administered DIN test and a commonly used self-report, the speech, spatial, and qualities of hearing (SSQ-12), for lab-based, supervised DIN and audiometry. Speech reception thresholds (SRTs) of 34 adults (18-64 y/o), 16 normal-hearing (NH) and 18 hearing-impaired (HI), were measured at home (remote-DIN) and in the lab (lab-DIN). All DIN testing used English digits 0-9, binaurally presented as triplets in different speech-shaped noise maskers (broadband, low-pass filtered at 2, 4, 8 kHz). Audiometry was administered during lab testing. An SSQ-12 e-version was completed by participants at home. As expected, NH listeners had significantly higher SSQ scores, and remote- and lab-DIN SRTs than HI listeners. All test versions of DIN were significantly correlated with pure-tone-average (PTA), with the 2-kHz filtered test the best predictor, explaining 50% of variance in PTA. SSQ also significantly predicted PTA. Overall, DIN-SRTs were better predictors of audiograms than the SSQ. Remote-DIN correlated significantly with lab-DIN, and there was no significant mean difference between remote- and lab-DIN. Test-retest reliability was measured for broadband remote-DIN. High, significant intraclass correlation coefficients indicated strong internal consistency of the remote-DIN. This study shows that remote SSQ-12 and DIN are valid screening tools for capturing important aspects of auditory function. The World Health Organization (WHO) estimates that the number of individuals with disabling hearing loss (i.e., threshold > 35 dB HL for the better ear) has been growing and is expected to increase to 2.5 billion by 2050 (WHO 2021) . Unaddressed hearing loss in adults not only affects communication, psychosocial well-being, and quality of life, but also has a substantial socio-economic impact (Olusanya et al. 2014) . The global annual cost of unaddressed hearing loss is estimated at 980 billion US dollars (WHO, 2021) . Late-diagnosed or untreated hearing loss also has detrimental effects on children's and youth's communication and cognitive skills, emotional well-being, and academic success (Moeller et al. 2007; Punch et al. 2004; Warner-Czyz et al. 2015) . Early detection and treatment of hearing loss is thus both care-and cost-effective in preserving hearing and quality of life for affected people (Davis et al. 2007; Karpa et al. 2010; Maharani et al., 2018) . Existing in-person audiological service delivery models are unable to address the global burden of hearing loss. Low-and middle-income countries (LMICs) experience barriers accessing specialized hearing care services due to factors including shortage of audiological professionals, equipment costs and centralized services (Swanepoel & Clark, 2019; Swanepoel & Hall, 2010) . Other factors such as transportation costs and accessibility, limited mobility and poor health also restrict patients' access to necessary hearing healthcare services, even in high income countries (Powell et al. 2019; Coco et . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 https://doi.org/10. .05.09.22274843 doi: medRxiv preprint al. 2016 Swanepoel & Hall, 2010) . The COVID-19 pandemic has further exposed the need for remote, valid hearing health care options. Advances in mobile technology and global connectivity through the internet have allowed development of sensitized web-and app-based screening and diagnostic tools that can improve assessment of auditory function in several ways. For example, smartphone deliverable variants of the digits-in-noise test (DIN) can reliably detect and differentiate sensorineural and conductive hearing loss (Smits et al. 2005; Potgieter et al. 2018; Motlagh Zadeh et al. 2020; De Sousa et al. 2018 . DIN is a relatively undemanding speech-in-noise test that measures speech recognition abilities objectively, reliably and quickly, in addition to having a strong correlation with audiometric thresholds (Smits et al. 2006; Ozimek et al. 2009; Leensen et al. 2011; Vlaming et al. 2014; Folmer et al. 2017; Motlagh Zadeh et al. 2019 . Moreover, unlike audiometry, DIN testing is accurate across different devices and headphone types without the requirement of calibration (Vlaming et al., 2014; Potgieter et al. 2016 ). DIN testing typically presents digits to listeners against a simultaneous background of broad-bandwidth, speech-shaped noise (Smits et al, 2004) . A speech reception threshold (SRT) is the usual outcome measure, the speech (digit) signal-tonoise ratio at which three successive digits are all correctly recognized on 50% of presentations (Vlaming et al. 2014) . During the past 10 years, the efficacy and sensitivity of the standard DIN test have been substantially increased using various test modifications such as low-pass filtering of the noise (Vlaming et al. 2014; Motlagh Zadeh et al. 2019; Motlagh Zadeh et al. 2020 ) and antiphasic presentation of the digits . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101 /2022 .05.09.22274843 doi: medRxiv preprint (De Sousa et al. 2018 De Sousa et al. 2020) . For example, De Sousa et al (2018) showed that presenting digits that are phase inverted (antiphasic) between the ears, while leaving the masking noise interaurally in-phase, significantly improves sensitivity of DIN test to asymmetric or unilateral sensorineural hearing loss (area under the receiver operating characteristic curve, AUROC = 0.94). Using low-pass filtering of the noise, Motlagh Zadeh et al (2020) sensitized the DIN test (92% sensitivity and 90% specificity) to high-frequency hearing loss as low as 20 dB from 2-14 kHz. The ability to deliver hearing tests outside the clinic has been long recognized as a potential major benefit of the DIN test. In this study we examined the predictive validity for pure-tone audiometry of self-administered DIN variants delivered to the same participants in the lab and at home. Previous studies have used remote or selfadministered DIN versions (Smits et al, 2004 and 2006; Folmer et al, 2017; De Sousa et al. 2021 ) but, to our knowledge, no study has directly compared results in the same listeners with standard, rigorous lab or clinic testing. Self-report is playing an increasing role in hearing assessment. The currently recognized complexity of hearing mechanisms, both within and outside the conventionally defined auditory system (Moore, 2018) , reduces the likelihood that one, or even a small number of tests is likely to capture the full experience of hearing. Selfreport can provide an overview of the listener experience in different circumstances and can also comment more widely on the usability and effectiveness of test procedures, and how hearing loss impacts on everyday life ('participation'). However, validation studies of self-report scales have generally been based on other scales and pure-tone audiometric thresholds (Humes et al, 2019) . Further examination of the relationship . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10. 1101 /2022 between self-report scales, speech-in-noise and other supra-threshold measures is needed. In this study, we relate and contrast pure-tone audiometry and DIN test with an e-version of the 12-item speech, spatial, and qualities of hearing scale (SSQ) completed at home by participants with either normal or impaired hearing. The original, 49-item SSQ measures self-reported ability for spatial hearing, sound segregation, and hearing speech in a variety of real-life contexts (Gatehouse et al. 2004 ). Noble and colleagues (2013) showed that SSQ-12 provides similar results to the original SSQ. Overall, this study aimed to validate the effectiveness of the remote, selfadministered DIN test and SSQ-12. According to the Global System for Mobile Communications Association (GSMA; 2020), 3.8 billion people were mobile internet users by the end of 2019. This number increased by 250 million compared to 2018. Importantly, 90% of new users were from LMICs. Validating reliable and sensitive hearing self-assessment tools thus has potential to increase access to hearing healthcare and subsequently improve quality of life for large global populations. Two groups of adult participants, 16 with normal hearing (NH; mean = 34.2 y/o, SD = 13.7) and 18 with hearing impairment (HI; mean = 49.1 y/o, SD = 13.8), mostly college graduates (64%; M= 34.2 y/o), were recruited from the Cincinnati Children's Hospital Medical Center (CCHMC) Research Electronic Data Capture (REDCap) online database, and via distribution of flyers at CCHMC and in the community. Flyers provided a brief description of the study and asked for adults 18 to 65 years old to contact our study staff if they had normal hearing, a diagnosis of hearing loss, or . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint suspected having a hearing loss. Flyers included contact information for the study staff. Interested participants (N= 42) received an initial screening questionnaire that enquired about their demographic information and history of ear and hearing disorders. Participants who met the hearing status criteria (described below) and age range (N= 40) were contacted by the study staff to schedule an assessment date. These participants received routine clinical assessment, including otoscopy, tympanometry, and pure tone audiometry to rule out conductive pathology and determine hearing thresholds across the standard frequency range (0.25 -8 kHz). Participants who did not meet the inclusion criteria for hearing status (i.e., either normal hearing, or sensorineural hearing loss at standard frequency range AND normal status of outer and middle ears) were excluded from the study (N= 6). All eligible participants completed the SSQ-12 remotely via REDCap and performed both remote and in-lab versions of DIN tests. Eighteen of 34 participants (7 NH and 11 HI) completed the lab testing (audiometry and DIN) 3 to 6 months before remote testing (SSQ and DIN). The remaining 16 participants (9 NH and 7 HI) did the remote testing 2 to 4 weeks before lab testing. Consent was given per guidelines set by the CCHMC Institutional Review Board. Pure tone audiometry was performed during lab testing using an Interacoustics Equinox 2.0 audiometer, calibrated to ANSI 3.6 (2010) standards. Thresholds from 0.25 to 8 kHz were obtained from participants in a double-walled sound booth meeting criteria of ANSI S3.1. Sennheiser HDA300 circumaural headphones were used to obtain air conduction . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint thresholds. HI was defined as audiometric thresholds > 20 dB HL in either ear at any frequency from 0.25 to 8 kHz ( Fig. 1 ). Stimuli and SRT determination: The digits 0-9 were recorded and homogenized for equal intelligibility based on the method described by Motlagh Zadeh et al. (2019) . Each presentation trial consisted of 3.25 s of masking noise in which three different digits were presented with an interval of 175 ms between digits. The noise was started and stopped 100 ms before and after each triplet presentation and was fixed at 65 dB SPL. The average length of each digit was 0.66 s. In Diotic mode, triplets were presented binaurally in-phase in one of 4 different noise maskers: broadband (BB) and three lowpass filtered (cutoff at 2, 4, 8 kHz) speech-shaped noises. We also tested binaurally antiphasic triplets in the BB noise version (De Sousa et al., 2020) . The DIN test was provided via the hearDigits® research website (hearX Group). The fixed order of DIN testing was as follows: 1-4) Diotic digits . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint in BB, 2 kHz, 4 kHz, and 8 kHz filtered noise; 5) Antiphasic digits in BB noise; 6) repeat Diotic digits in BB noise to ascertain short-term test-retest reliability. Testing took about 30 minutes to complete. Participants were instructed to use whatever headphones (or earbuds) they had available with any device (PC/smartphone/tablet) that had a compatible web browser (Chrome, Firefox or Safari). Each remote generated .csv file contained detailed test information including: participant identification number, name, date of birth, test mode (Diotic or Antiphasic), noise version (BB or low-pass filtered at 2, 4, 8 kHz), and trial by trial presented triplets, SNR and responses. The lab DIN-SRTs were also obtained via the hearDigits® research website and followed the same order of DIN testing as the remote procedure. The lab-DIN test was administered using Sennheiser 215 headphones connected to an iPad in a double-walled sound booth meeting criteria of ANSI S3.1. No test-retest was done for the lab testing since the reliability of lab procedures has already been established (Motlagh-Zadeh et al, 2020). An e-version (administered via REDCap) of the SSQ-12 (Noble et al, 2013 ) was given to participants at the time of remote testing. As specified, participants were instructed to respond to prompts by moving a virtual slider that ran from 0 to 10, where 10 meant they were perfectly able to do or experience what was described in the question, and where 0 meant they were quite unable to do or experience what was described in the question. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; Initially, univariate analysis was conducted to explore the individual variable (SSQ scores and DIN-SRTs) impact on the outcome (better ear PTA) via Pearson correlation and t-test. Variables of at least marginal significance (p < 0.1) in the univariate analysis were considered as potential predictors for a subsequent multiple regression. Considering the highly correlated predictors, multicollinearity was assessed by variance inflation factors (VIF). Stepwise regression was performed to select the most parsimonious model. All data were analyzed in SAS v9.4 (The SAS Institute, Cary, NC) with two-sided significance levels of 0.05. All 34 participants who met the inclusion criteria completed home-and lab-based testing successfully. Figure 1a shows the hearing thresholds for both NH and HI groups. Half the participants in the HI group (n = 9) had PTA < 20 dB (average of all frequencies in both ears, Fig. 1b ). Two of 18 participants in the HI group (dashed gray lines, Fig. 1a ) had asymmetric loss (interaural difference ≥ 15 dB at three contiguous frequencies; AAO-HNS,1993 and 1994) . The HI group was thus heterogeneous in both degree and symmetry of their hearing loss. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Test-retest reliability was measured for diotic BB remote-DIN in all participants. A high and significant intraclass correlation coefficient (ICC=0.80, p < 0.0001) indicated strong internal consistency and reliability of the remote-DIN test (Fig. 2) . Reliable results were found separately for both NH (ICC=0.58, p < 0.01) and HI (ICC=0.80, p < 0.0001) groups. ., . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint Table 1 shows the mean DIN-SRTs for remote and lab test conditions in the NH, HI, and both groups combined. Mean remote SRTs did not differ significantly from mean lab SRTs in any test version. Across all participants, lab-and remote-SRTs correlated significantly in all test versions (Fig. 3 , black regression lines). Diotic-BB was the only test version in which the lab-and remote-SRTs were significantly correlated in both groups of participants (NH and HI). Regression lines in Figure 3 suggest a trend toward better SRTs in the lab for listeners with HI. However, there were outliers in both environments in this group and all differences between environments were nonsignificant. for lid for ab d . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. hearing. Least-square regression lines indicate significant correlations among the Total sample (bold) and within each group (dotted). The group (N= 18; 7 NH and 11 HI) who completed the lab testing (audiometry and DIN) 3 to 6 months before remote testing (SSQ and DIN) had significantly (p= 0.02) higher mean DIN-SRTs than the group (N=16; 9 NH and 7 HI) who did the remote testing 2 to 4 weeks before lab testing. We did not find a significant mean difference between testretest SRTs for each subgroup. Thus, the significant mean-SRT difference found between the two subgroups could be attributed to the higher number of subjects with HI in the first subgroup who also had poorer hearing thresholds (p= 0.001) compared to the second subgroup. Remote-DIN SRTs were also compared with lab-measured, better-ear PTA (BE-PTA 0.25, 0.5, 1, 2, 4, 8 kHz ) to examine sensitivity of the remote-DIN test as a measure of hearing loss. Multiple regression analysis showed that, overall, remote-DIN SRTs explained 48% of variance in BE-PTA (F (5, 28) = 7.15, p = 0.0002). Figure 4 shows that all 5 versions of the remote-DIN significantly predicted BE-PTA (p < 0.001 for total sample in each test). Diotic SRT with 2 kHz filtered noise was the best predictor, explaining 50% of audiogram variance. Diotic-BB was the only test version in which PTA and SRT were significantly correlated in each group of participants (NH and HI). The slope of the Total regression line was also steeper in the diotic-BB than in any other version because the range and variability of SRT between participants was narrower. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint (Table 2a) . Overall, mean SSQ score was significantly higher (p = 0.03) in the NH than in the HI group. Among the 9 pragmatic subscales of SSQ (see appendix ; Noble et al, 2013) , speech-in-speech, speech-in-noise, and quality and naturalness subscales had significantly higher mean scores in the NH than in the HI group (Table 2b) . . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint There was a significant correlation between the remote DIN-SRTs and the SSQ scores across all listeners in all test versions, except the antiphasic BB-DIN test, where the relation was a non-significant trend (Fig. 5) . Correlations were also significant in the HI group for the diotic BB and 4 and 8 kHz low-pass filtered test versions (Fig. 5) . The diotic BB version had the highest correlations and, again, the steepest regression slope. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 Even though SSQ was a significant predictor of BE-PTA ( Figure 6 ; F (1, 32) =7.69, p = 0.009), it accounted for only 17% of variance in BE-PTA. Within group comparison showed the correlation was significant only for the NH group (Fig. 6) . However, significant correlations were found for both groups and the Total score (r = -0.48 to -0.63, p = 0.04 -0.001) when we compared SSQ scores with poorer ear PTA. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 The primary purpose of this study was to examine the reliability of remote, selfadministered DIN variants. A secondary aim was to examine predictive validity of the remote DIN and a self-report scale in comparison with each other and with pure-tone audiometry. Our results demonstrated the feasibility, reliability and validity of the DIN and SSQ-12 measures in a remote setting. Specifically, the DIN tests selfadministered by our participants at home showed a strong correlation with the labversion of the test, regardless of the types of headphones (or earbuds) and device (PC/smartphone/tablet) they used at home. All versions of the remote-DIN significantly predicted the audiogram, with the 2 kHz filtered version explaining 50% of audiogram variance. Current results were consistent with our previous studies (Motlagh Zadeh et al., 2020) showing lab-measured 2 kHz low-pass filtered DIN was the best version for detecting hearing loss between 0.25 to 4 kHz. Despite compressed scoring ranges, . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101 https://doi.org/10. /2022 SSQ also predicted PTA, with speech-in-noise and sound quality being the main predictors, rather than spatial hearing. All participants were able to perform and complete the remote tasks. Although our sample of participants was mostly young, college-graduate adults (64%; M= 34.2 y/o), 35% were older (> 50 y/o) and none of them reported any difficulty self-administering the DIN test at home. The results have applied significance, especially in the current Covid-19 pandemic that has moved audiology towards greater remote testing and accessibility, personalization and efficiency. Findings show that quantitative remote testing can be used without sacrificing quality. Smartphone-mediated telehealth holds great promise to mitigate many of the barriers that prevent access to specialized hearing healthcare services (Swanepoel & Clark, 2019) . Global availability of affordable internet, computers, and mobile phones allows access to reliable, undemanding hearing assessment. These developments enable early identification and management of hearing loss, particularly for underserved communities, like rural populations and people who are unable to travel to receive in-person services De Sousa et al, 2020) . In addition to hearing loss detection, DIN tests have been shown to be useful for measuring the benefits of hearing devices, and for fitting hearing aids (Potgieter et al, 2018; Van der Mescht et al. In Press) . Because they can be used at home, they can be helpful in monitoring hearing, for example for people with age-related hearing loss who have not yet chosen to use a hearing aid. With the development of drugs to protect hearing (Schilder et al, 2019) , remote hearing assessment like DIN will be important . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint both to detect candidates for drug administration and to monitor the effects of those drugs at home and on a regular basis. In addition, DIN test has the potential to be used as a primary hearing screen in schools (for children 6+ y/o; Denys et al., 2018 and , and for patients who would benefit from frequent monitoring of ototoxicity, for example during aminoglycoside or cisplatin treatment. Results of self-report (SSQ-12) were also significantly correlated with audiograms and DIN tests. These findings are consistent with our previous study (Motlagh Zadeh et al., 2019) , showing that the extent of hearing loss was related to the number of individuals self-reporting difficulty hearing in noise. Louw et al (2018) also showed that combining self-report with an audiometry screen increases test sensitivity (81.0%) for hearing loss, being most sensitive (86.1%) to identify high-frequency hearing loss. Moreover, Heinrich et al (2015) found that hearing-related self-report scales correlate significantly with different measures of speech perception in noise (e.g., DIN and sentence in noise test). These findings combined with our finding of speech-innoise being the most significant subscale of SSQ-12 for distinguishing the HI group from the NH supports the importance of including a speech-in-noise test in routine audiological assessment. Perceived hearing difficulty in the presence of normal audiometric thresholds is a clinical challenge that is not currently being effectively addressed. Recently Doherty and Singh (2020) used self-report trouble hearing in noise to measure benefits of a mild-gain hearing aid for middle-age adults with clinically normal hearing. They found that, after wearing the hearing aid for 2 weeks, participants who previously self-reported difficulty hearing in noise had improved hearing handicap scores compared to those reporting no . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint difficulty hearing in noise. Overall, linking audiometry and a speech-in-noise testing to self-report measures of listening difficulties enhances our understanding of the listener experience in different circumstances and can also comment more widely on the usability and effectiveness of test procedures. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted May 10, 2022. ; https://doi.org/10.1101/2022.05.09.22274843 doi: medRxiv preprint Community-Based Intervention Determines Tele-Audiology Site Candidacy benefit and costs of early screening for hearing disability: A study of potential screening tests and models A smartphone national hearing test: performance and charectristics of users Pure-tone audiometry without bone-conduction thresholds: using the digits-in-noise test to detect conductive hearing loss Digital Technology for Remote Hearing Assessment-Current Status and Future Directions for Consumers School-Age Hearing Screening Based on Speech-in-Noise Perception Using the Digit Triplet Test The digit triplet test as a self-test for hearing screening at the age of school-entry Validation of a computer-administered version of the digits-in-noise test for hearing screening in the United States The speech, spatial and qualities of hearing scale (SSQ) GSMA The relationship of speech intelligibility with hearing sensitivity, cognition, and perceived hearing difficulties varies for different speech perception tests A Follow-Up Clinical Trial Evaluating the Consumer-Decides Service Delivery Model Associations between hearing impairment and mortality risk in older persons: The Blue Mountains Hearing Study Speech-in-noise screening tests by internet. Part 1: test evaluation for noise-induced hearing loss identification Self-Reported Hearing Loss and Pure Tone Audiometry for Screening in Primary Health Care Clinics Longitudinal Relationship Between Hearing Aid Use and Cognitive Function in Older Americans Current state of knowledge: Language and literacy of children with hearing impairment Challenges in Diagnosing Auditory Processing Disorder Extended high frequency hearing enhances speech perception in noise Improved Sensitivity of Digits-in-Noise Test to High-Frequency Hearing Loss A short form of the Speech, Spatial and Qualities of Hearing scale suitable for clinical use: the SSQ12 The global burden of disabling hearing impairment: a call to action Development and evaluation of Polish digit triplet test for auditory screening Development and validation of a smartphone-based digits-in-noise hearing test in South African English The south african english smartphone digits-in-noise hearing test: Effect of age, hearing loss, and speaking competence Rural Adult Perspectives on Impact of Hearing Loss and Barriers to Care Issues in the school-to-work transition of hard of hearing adolescents Hearing protection, restoration, and regeneration: An overview of emerging therapeutics for inner ear and central hearing disorders Use of a Mild-Gain Hearing Aid by Middle-Age Normal-Hearing Adults Who Do and Do Not Self-Report Trouble Hearing in Background Noise Development and validation of an automatic speech-in-noise screening test by telephone Results from the Dutch speech-in-noise screening test by telephone Speech reception thresholds in noise and self-reported hearing disability in a general adult population A systematic review of telehealth applications in audiology Hearing healthcare in remote or resourceconstrained environments Mobile applications to detect hearing impairment: opportunities and challenges Automated screening for high-frequency hearing loss Remote monitoring of adult cochlear implant recipients using digits-in-noise self-testing