key: cord-0311671-lz3y8rlj authors: Denninger, Viola; Xu, Catherine K.; Meisl, Georg; Morgunov, Alexey S.; Fiedler, Sebastian; Ilsley, Alison; Emmenegger, Marc; Malik, Anisa Y.; Piziorska, Monika A.; Schneider, Matthias M.; Devenish, Sean R. A.; Kosmoliaptsis, Vasilis; Aguzzi, Adriano; Fiegler, Heike; Knowles, Tuomas P. J. title: Understanding the role of memory re-activation and cross-reactivity in the defense against SARS-CoV-2 date: 2021-07-23 journal: bioRxiv DOI: 10.1101/2021.07.23.453352 sha: d2321c7320bc6ddf29441a84622f1f09e3f17b1a doc_id: 311671 cord_uid: lz3y8rlj Recent efforts in understanding the course and severity of SARS-CoV-2 infections have highlighted both potential beneficial as well as detrimental effects of cross-reactive antibodies derived from memory immunity. Specifically, due to a significant degree of sequence similarity between SARS-CoV-2 and other members of the coronavirus family, memory B-cells that emerged from previous infections with endemic human coronaviruses (HCoVs) could be re-activated upon encountering the newly emerged SARS-CoV-2, thus prompting the production of cross-reactive antibodies. Understanding the affinity and concentration of these potentially cross-reactive antibodies to the new SARS-CoV-2 antigens is therefore particularly important when assessing both existing immunity against common HCoVs and adverse effects like antibody-dependent enhancement (ADE) in COVID-19. However, these two fundamental parameters cannot easily be deconvoluted by surface-based assays like enzyme-linked immunosorbent assays (ELISAs) which are routinely used to assess cross-reactivity. Here, we have used microfluidic antibody-affinity profiling (MAAP) to quantitatively evaluate the humoral immune response in COVID-19 convalescent patients by determining both antibody affinity and concentration against spike antigens of SARS-CoV-2 directly in nine convalescent COVID-19 patient and three pre-pandemic sera that were seropositive for common HCoVs. All 12 sera contained low concentrations of high affinity antibodies against spike antigens of HCoV-NL63 and HCoV-HKU1, indicative of past exposure to these pathogens, while the affinity against the SARS-CoV-2 spike protein was lower. These results suggest that cross-reactivity as a consequence of memory re-activation upon an acute SARS-CoV-2 infection may not be a significant factor in generating immunity against SARS-CoV-2. Despite the increasing availability of diagnostic tests, antibody treatments and vaccines, the COVID-19 pandemic still presents a major challenge to governments and healthcare systems all over the world, requiring a functional assessment of the immune response to SARS-CoV-2. Research focuses increasingly around the role of acute increased production of pro-inflammatory cytokines and the recall of memory T-and B-cells which were formed during previous infections with other coronaviruses¹ -⁴. In contrast to SARS-CoV-2, common human coronaviruses (HCoVs), although omnipresent and recurrent, generally cause mild disease only⁵. HCoVs can be detected throughout all age-groups with most individuals seroconverting during childhood⁶ , ⁷. Re-infection subsequently leads to antibody affinity maturation, resulting in a natural build-up of protective memory T-and B-cells as well as long lived plasma cells (LLPCs) that in some cases can persist up to a year⁸ , ⁹. In the event of the emergence of new but highly homologous coronavirus species, memory B-cells might recognize the antigens of the new species, re-activate and accelerate the immune response to the new virus, prompting the production of cross-reactive antibodies¹⁰. Although immunity derived from previous infections with similar viruses is generally advantageous, cross-reactive antibodies can cause antibody-dependent enhancement (ADE) of the viral infection in a subset of individuals¹⁰ , ¹¹. In these cases, cross-reactive antibodies, although able to recognize and bind the new viral antigens, not only fail to neutralize the virus due to sub-neutralizing concentrations, insufficiently high affinity, or binding to an inappropriate region, but more importantly facilitate its reproduction via an Fc-receptor mediated uptake into the host cell. Cross-reactivity mediated ADE has been shown to elevate the disease severity of infections with flaviviruses, especially for Dengue and Zika viruses, and is therefore a key consideration in the development of vaccines and therapies for COVID-19¹² -¹⁴. Cross-reactivity of antibodies is traditionally assessed using enzyme-linked immunosorbent assays (ELISAs). These assays report titers only and cannot readily resolve the fundamental parameters of antibody responses, namely affinity and concentration¹⁵, which are crucial for monitoring the effectiveness of humoral immunity after natural infection and after vaccination. Here, we have used microfluidic antibody-affinity profiling (MAAP)¹⁵ -¹⁷ to quantify the cross-reactivity of antibodies against SARS-CoV-2 S1, S2 and the receptor binding domain (RBD) in nine convalescent COVID-19 patient samples and three pre-pandemic controls, and compared our results to standard ELISA assays. While MAAP matched the ELISA data qualitatively, crucially it enabled the simultaneous and independent determination of antibody affinities and concentrations to reveal interindividual variation of antibody responses to SARS-CoV-2 not detectable by ELISA. Interestingly, testing all 12 serum samples in a reciprocal approach for antibodies against the corresponding antigens of two common HCoVs, namely HCoV-NL63 and HCoV-HKU1, revealed high antibody affinity and low concentrations across all samples tested. This indicates the presence of matured antibodies against both common HCoVs, rather than cross-reactive antibodies that were derived from the immune response against SARS-CoV-2. This observation was further confirmed by single point competition assays using the SARS-CoV-2 RBD and HCoV-NL63 RBD antigens. Our data therefore suggests no significant cross-reactivity of antibodies against common HCoVs to SARS-CoV-2 and vice versa, indicating that B-cell mediated immunological memory from past infections with common HCoVs is unlikely to have a significant role in SARS-CoV-2 specific immune response. Before assessing cross-reactivity, we first quantified the immune response to SARS-CoV-2 in nine seropositive convalescent COVID-19 patient samples using MAAP¹⁶. In addition to profiling the receptor binding domain (RBD), we extended the assay to also include the spike S1 and S2 subunits as the spike S2 subunit had previously been reported to comprise regions of high homology with other human coronaviruses and therefore may confer a higher probability of cross-reactivity to antibodies from previous infections¹⁸. MAAP against the SARS-CoV-2 RBD region revealed K D values ranging from 1-28 nM which is consistent with previously reported values in patients with acute COVID-19 infections¹⁶ ( Figure 1A) . Interestingly, serum samples 4 and 5 not only contained high concentrations of antibody binding sites against the SARS-CoV-2 RBD region (serum 4: 169 nM (CI 95%: 123-208) and serum 5: 231 nM (CI 95%: 152-285)), but also against SARS-CoV-2 spike S1 (serum 4: 100 nM (CI 95%: 81-123), and serum 5: 480 nM (CI 95%: 351-533)) and SARS-CoV-2 spike S2 (serum 4: 90 nM (CI 95%: 66-100), and serum 5: 351 nM (CI 95%: 231-390)). This may be due to earlier sampling in these patients after recovery from COVID-19 compared to the other seven sera tested, so that the antibody concentration had not declined significantly yet. All nine convalescent serum samples contained antibodies with high affinity to the S2 subunit of SARS-CoV-2 spike with the majority of the K D values in the lower nanomolar to even sub-nanomolar range. There was no correlation between the concentration of antibody binding sites against the S2 subunit and the RBD region, supporting previous reports that indicate highly variable immune responses between individual patients towards these two different antigens¹⁸ , ¹⁹. While antibodies in all nine convalescent sera were found to bind tightly to the S2 subunit, we found considerable variation in affinity and concentration of serum antibodies when using MAAP against the S1 subunit. Two out of nine convalescent serum samples exhibited tight binding (K D <10 nM) but low concentrations of antibody binding sites against the spike S1 subunit (sera 6 and 7). Moreover, for serum 1 no affinity could be determined potentially due to low antibody concentration or affinity. A further four samples did not show any binding to spike S1 (sera 2, 3, 8 and 9), potentially due to a closed conformational state of the S1 subunit, obscuring crucial epitopes from antibody binding as previously observed for HCoV-229E²⁰ -²² (Suppl. Table 1) . To validate these results by use of an independent assay, we also subjected the convalescent serum samples to a standard ELISA. As ELISAs employ antigens that are immobilized to a surface rather than measuring the interaction in solution, the assay output is strongly dependent on the combination of antibody affinity, avidity and concentration. However, the assay does not report on these crucial parameters individually. While the ELISA qualitatively corroborated the MAAP results and identified sera 4 and 5 as the strongest responders to all three SARS-CoV-2 antigens (Figure 1B) , our assay in addition deconvoluted the respective contributions of antibody affinity and concentration towards the qualitative EC 50 values determined by the ELISA assay. Pre-pandemic 2 Pre-pandemic 1 Convalescent 8 Convalescent 7 Convalescent 5 Convalescent 3 Low High SARS-CoV-2 S2 + Patient serum Alexa647 RBD S1 Color key Highly specific antibodies against HCoV-NL63 and HCoV-HKU1 spike S1 and RBD are present at low concentrations in convalescent COVID-19 and pre-pandemic sera Receptor-mediated cell entry of coronaviruses typically depends on the interaction of the spike protein with a target receptor that is specific to each coronavirus. Opposed to that, it was shown that neutralizing antibodies targeting the spike proteins of SARS-CoV and MERS-CoV can instead facilitate Fc-receptor mediated cell entry and virus propagation¹¹ , ²³, a mechanism typical for ADE. This raises the possibility of cross-reactive anti-spike antibodies influencing acute SARS-CoV-2 infections or vaccinations. Indeed, several recent studies have investigated cross-reactivity between SARS-CoV-2 and HCoV antibodies, with particular focus on antibody binding to the spike protein and RBD⁴ , ¹⁹ , ²⁴ , ²⁵. The studies found that most pre-pandemic sera contained antibodies that bind to the spike protein of all common HCoVs, while binding to the spike protein of SARS-CoV-2 was observed less frequently. Conversely, convalescent COVID-19 patient sera seemed to show cross-reactivity to the spike protein of all common HCoVs, albeit to different degrees⁴ , ¹⁶ , ¹⁹. To test these observations in our system, we used MAAP against the RBD and S1 subunit of HCoV-NL63 and HCoV-HKU1. Even though sequence alignment of the full length spike proteins of both HCoVs with the SARS-CoV-2 spike protein revealed ~30% sequence identity at the amino acid level, the betacoronavirus HCoV-HKU1 was previously reported to be more readily recognized by cross-reactive antibodies in sera of recovered COVID-19 patients⁴ , ¹⁹. As HCoV-HKU1 binds to a different cell receptor however, structural differences are likely in the RBD region, the most crucial antigen for binding of potentially neutralizing, cross-reactive antibodies. HCoV-NL63 on the other hand, like SARS-CoV-2, binds to the cell-surface receptor ACE2 to enter the host cell, resulting in similarities in the RBD²⁶. As an initial proof of concept, we determined the binding affinity of a recombinantly expressed neutralizing anti-SARS-CoV-2 RBD antibody to the S1-subunits of HCoV-NL63 and HCoV-HKU1, respectively. To do so, we measured the hydrodynamic radius, R h , of the fluorescently labeled S1-subunits (Figures 2A and B ) at increasing concentrations of the anti-SARS-CoV-2 RBD antibody. Whereas the antibody readily bound SARS-CoV-2 S1 with a K D of ~5 nM (data not shown), the size of both labeled HCoV S1 subunits remained unchanged, even up to antibody concentrations of 500 nM, indicating the absence of binding. As a control, the same assay was performed titrating an anti-HKU1 antibody against fluorescently labeled HCoV-HKU1 spike S1 (Figure 2C ), clearly showing a high affinity of the antibody to the labeled HCoV-HKU1-antigen (K D <100 pM). These results indicate that there is no substantial cross-reactivity with the S1 subunits of HCoV-HKU1 and HCoV-NL63 for the anti-SARS-CoV-2 RBD antibody investigated here, even though HCoV-NL63 and SARS-CoV-2 share ACE2 as their target receptor²⁷. After this initial proof of concept, we tested the previously mentioned nine convalescent COVID-19 patient sera ( Figure 2D ) together with three pre-pandemic sera, one of which was previously confirmed to be seropositive for HCoV-NL63 and HCoV-HKU1 (pre-pandemic serum 2), and another one to be seropositive for HCoV-NL63 only (pre-pandemic serum 1). In all nine convalescent sera we detected moderate concentrations of antibody binding sites for HCoV-NL63 RBD and S1, ranging from 17 to 40 nM and from 27 to 60 nM (Figure 2C and Suppl. Table 2 ). Concentrations of antibody binding sites against the respective HCoV-HKU1 antigens were even lower with 3.4-22 nM for HCoV-HKU1 RBD and 3.5-37 nM for HCoV-HKU1 S1 (Suppl. Figure 1 and Suppl. Table 3 ). With concentrations >90 nM, only one pre-pandemic serum (pre-pandemic serum 2) exhibited higher levels of antibody binding sites against the S1 subunits of HCoV-NL63 and HCoV-HKU1, indicative of an increased antibody production likely in response to a recent infection with both viruses. Intriguingly, with K D values <3.6 nM, all sera contained antibodies with very high affinities against the two HCoV-NL63 antigens. Furthermore, affinities against HCoV-HKU1 RBD were in the sub-nanomolar range throughout all samples that were subjected to the MAAP assay. The high specificity towards HCoV-NL63 and HCoV-HKU1 epitopes indicates that these antibodies were not produced in response to SARS-CoV-2, but were rather derived from memory immunity. Based on our observations as well as previously published reports⁴ , ⁶ , ²⁸, we hypothesize that the antibodies we detected with use of our MAAP assay are part of a general background immunity of high affinity circulating serum antibodies against HCoV-NL63 and HCoV-HKU1 that were produced in response to previous infections. HCoV-HKU1 S1 HCoV-NL63 S1 HCoV-HKU1 S1 B Alexa647 Alexa647 Alexa647 + + + Alexa647 S1 S1 Alexa647 RBD S1 S1 Pre-pandemic sera show no significant cross-reactivity against SARS-CoV-2 spike S1, S2 and RBD Given the ubiquitous prevalence and high re-infection rate of common HCoVs²⁹, it is likely that most individuals will have preexisting antibodies deriving from immunological memory circulating in the bloodstream at concentrations comparatively lower than those in response to an acute infection⁹. If cross-reactive to SARS-CoV-2 antigens, these preexisting antibodies could not only impact the accuracy of diagnostic tests for SARS-CoV-2 infections, but could also present a risk for ADE, and thus potentially affect the severity of the immune response after infection. It is therefore crucial to further examine the ability of anti-HCoV antibodies to recognize and bind SARS-CoV-2 antigens. To probe for the cross-reactive potential of these antibodies against the corresponding SARS-CoV-2 epitopes, we performed MAAP assays against the three SARS-CoV-2 antigens, spike S1, spike S2 and RBD in the three pre-pandemic sera. Interestingly, affinity profiling did not reveal any detectable binding of preexisting antibodies to SARS-CoV-2 RBD, spike S1 or spike S2 in the three pre-pandemic sera (Figure 1A and Suppl. Table 1) . To further investigate, we then assessed cross-reactivity directly via a competition assay based on the principle described in Schneider et al¹⁶ and Fiedler et al¹⁷ ( Figure 3A) . For this approach, a quantity of each serum corresponding to 20 nM antibody binding sites was mixed with 10 nM labeled HCoV-NL63 RBD, to allow at least 80% of the labeled antigen to be bound by antibodies. After equilibration, the mixture was subjected to microfluidic diffusional sizing, and complex formation was confirmed by the increase of the apparent R h . For competition, an excess of 250 nM unlabeled SARS-CoV-2 RBD was added to the HCoV-NL63 RBD-antibody complex, and R h was measured after establishment of binding equilibrium. If antibodies bound to the RBD of HCoV-NL63 were cross-reactive, the excess unlabeled SARS-CoV-2 RBD would outcompete the binding, resulting in an unbound HCoV-NL63 RBD and therefore a decrease in R h compared to that of the antibody complexed HCoV-NL63 RBD. Using this approach, we again tested the nine convalescent COVID-19 as well as the three HCoV pre-pandemic sera. We found that even upon addition of excess unlabeled SARS-CoV-2 RBD, the R h did not decrease in any of the samples, indicating that all antibodies stayed tightly bound in a complex with labeled HCoV-NL63 RBD, and thus were not cross-reactive with SARS-CoV-2 RBD (Figure 3B) . Two convalescent COVID-19 serum samples however, serum 7 and serum 8, presented an interesting exception, as their complex size increased upon addition of unlabeled SARS-CoV-2 RBD. This was likely due to unsaturated antibody binding sites that were still free to bind some of the SARS-CoV-2 RBD protein, but with a low affinity unable to outcompete the interaction with labeled HCoV-NL63 RBD (Suppl . Tables 1 and 2) . Additionally, we observed greater variations of initial HCoV-NL63 RBD-antibody complex sizes within the pool of convalescent COVID-19 serum samples (R h = 5.9-9.6 nm) compared to the pre-pandemic sera (R h = 7.3-8.0 nm). This observation is in line with the fact that our cohort derived from recently COVID-19 recovered patients which contained antibody types of different sizes, namely IgG and IgM. Based on these results, even though we cannot fully exclude cross-reactivity against the SARS-CoV-2 RBD, we would expect cross-reactive antibodies to exhibit at least 10-fold lower affinity to the SARS-CoV-2 RBD region compared to its original antigen. HCoV-NL63 cross-reactivity competition assay. 10 nM fluorescently labeled HCoV-NL63 RBD was mixed either with buffer or with patient serum, incubated 1 h and subjected to microfluidic diffusional sizing, to determine the size of the free labeled RBD (R h,free ) and the size of the immune-complex (R h,complex ). For binding competition, 250 nM unlabeled SARS-CoV-2 RBD was added to the mixture of 10 nM HCoV-NL63 RBD and patient serum and incubated for 1 h before measuring the hydrodynamic radius (R h ). If the serum contains cross-reactive antibodies, a size decrease is observed, as the antibodies will bind to the excess of unlabeled RBD (left box). If the antibodies in the serum are not cross-reactive, they remain bound to the labeled HCoV-NL63 RBD and the R h of the immuno-complex will stay constant (right box). Protective and adverse effects of antibody cross-reactivity can influence the humoral immune response of an individual to an acute infection, vaccination, or treatment. In this study, we have employed microfluidic antibody-affinity profiling (MAAP) to quantitatively investigate cross-reactivity against SARS-CoV-2 and two common coronaviruses, HCoV-NL63 and HCoV-HKU1, in nine convalescent COVID-19 and three pre-pandemic sera. This enabled us to quantify the affinity and concentration of antibodies against different spike subunits of the three coronaviruses, allowing a differentiation between antibodies raised in response to an acute infection and those originating from immunological memory. Affinity profiling against different SARS-CoV-2 spike antigens revealed a wide range of antibody affinities and concentrations in all convalescent sera, especially against the RBD and the S1 subunit of SARS-CoV-2. In our cohort, this variability suggests a de novo synthesis of antibodies in response to a SARS-CoV-2 infection, further supported by the fact, that we did not find evidence for significant cross-reactivity of antibodies against SARS-CoV-2 spike antigens in pre-pandemic, HCoV-seropositive sera. This contrasts with the antibody affinities and concentrations that were found when profiling the same 12 sera against spike S1 and RBD from HCoV-NL63 and HCoV-HKU1. With the exception of one pre-pandemic serum that was seropositive for all common HCoVs and thus showed elevated levels of antibodies against HCoV-NL63 and HCoV-HKU1, all sera tested contained antibodies with high affinity, but at relatively low antibody concentrations. Consistent with epidemiological studies on infection patterns of HCoV-NL63 and HCoV-HKU1³⁰, this suggests the existence of a low amount of circulating antibodies against the RBD and the S1 subunit of the two HCoVs, that already underwent affinity maturation in response to re-occurring infections, rather than being the result of cross-reactivity induced re-call of memory B-cells²⁸. By deconvoluting the humoral immune response into affinity and concentration of serum antibodies, MAAP generates an individual fingerprint for each sample, providing crucial insights into the immunological landscape of de novo and reoccurring infections. This unique quantitative approach therefore delivers new prospects to monitor immune induction following a vaccination or a treatment more precisely, helping to evaluate the efficacy of antibody production and to assess the potential risks of humoral memory. Sequence alignment of coronavirus full length spikes was performed using the Clustal Omega Sequence Alignment Tool. Input sequences were HCoV-NL63 (UniProt ID: Q6Q1S2), HCoV-HKU1 (UniProt ID: Q5MQD0) and SARS-CoV-2 (UniProt ID: P0DTC2). All serum samples from COVID-19 convalescent patients as well as the pre-COVID sera were purchased from BioIVT. Pre-COVID sera were seropositive for the following coronaviruses: serum 1 (HCoV-229E, HCoV-NL63), serum 2 (HCoV-229E, HCoV-NL63, HCoV-OC43, HCoV-HKU1) and serum 3 (HCoV-229E). BioIVT sought informed consent from each subject, or the subjects legally authorized representative and appropriately documented this in writing. All samples are collected under IRB-approved protocols. ELISA-based serology was carried out as previously described²⁴ , ³¹, with minor modifications. High-binding 384-well plates (Perkin Elmer, SpectraPlate 384 HB) were coated with 20 µL 1 µg/mL spike ectodomain (Lausanne, EPFL SV PTECH PTPSP), RBD (Lausanne, EPFL SV PTECH PTPSP), or spike S1 domain (S1N-C52H4, Acro Biosystems) in PBS at 37 °C for 1 h, followed by 3 washes with PBS 0.1% Tween-20 (PBS-T) using a Biotek EL406 plate washer and blocked with 40 µL 5% milk in PBS-T for 1.5 h. Serum samples were serially diluted (range: 0.02 -1.2x10 -6 ) in sample buffer (1% milk in PBS-T) and added to wells (20 µL/well). After sample incubation for 2 h at RT, the wells were washed five times with wash buffer and the presence of IgGs directed against above-defined SARS-CoV-2 antigens was detected using an HRP-linked anti-human IgG antibody (Peroxidase Af-finiPure Goat Anti-Human IgG, Fcγ Fragment Specific, Jackson, 109-035-098, at 1:4000 dilution in sample buffer) at 20 µL/well. The incubation of the secondary antibody for one hour at RT was followed by three washes with PBS-T, the addition of TMB, an incubation of five minutes at RT, and theaddition of 0.5 M H 2 SO 4 . The plates were centrifuged after all dispensing steps, except for the addition of TMB. The absorbance at 450 nm was measured in a plate reader (Perkin Elmer, EnVision) and the inflection points of the sigmoidal binding curves (p(EC 50 ) or -log(EC 50 ) values of the respective sample dilution) were determined using the custom designed fitting algorithm previously reported²⁴. The p(EC 50 ) values for all samples and antigens were visualized using the ggplot2 package in R. SARS-CoV-2 S1 protein (S1N-C52H4), SARS-CoV-2 S protein RBD (SPD-C52H3) and SARS-CoV-2 S2 protein (S2N-C52H5) were purchased from Acro Biosystems. HCoV-NL63 S1 protein (40600-V08H) and HCoV-HKU1 S1 protein (40021-V08H) were purchased from Sino Biological. HCoV-NL63 Spike RBD (10605-CV) and HCoV-HKU1 Spike RBD (10600-CV) were obtained from R&D Systems. All proteins were reconstituted according to manufacturers' instructions. For fluorescent labeling, the protein was diluted into labeling buffer (1 M NaHCO3 pH 8.3) to give a final concentration of 0.2 M NaHCO 3 , followed by the addition of Alexa Fluor™ 647 NHS ester (A2006, Thermo Scientific) at a molar dye-to-protein ratio of 3:1. Following incubation overnight at 4 °C, the labeled proteins were purified by size exclusion chromatography (SEC) on an ÄKTA pure system (Cytiva) with phosphate buffered saline (PBS) at pH 7.4 (P4417, Merck) as elution buffer. For SEC-purification of RBD proteins a Superdex 75 Increase 10/300 GL column was used, the larger S1 and S2 proteins were purified using a Superdex 200 Increase 3.2/300 column (Cytiva). Pooled fractions that correspond to the labeled protein were concentrated, snap frozen and stored at -80 °C with 10% v/v glycerol as a cryoprotectant. Equilibrium affinity binding curves of recombinant antibodies against S1 proteins of HCoV-HKU1 and HCoV-NL63 For affinity measurements of anti-human coronavirus spike glycoprotein HKU1 (40021-MM07-100, Sino Biological) to HCoV-HKU1 S1 protein, the antibody was reconstituted according to the manufacturer's instructions and diluted into PBS, containing 0.05% Tween 20 and 5% human serum albumin (HSA), to achieve a two-fold concentration series ranging from 60 pM to 1 µM. Antibody dilutions were subsequently mixed in a 1:1 ratio with a 20 nM solution of Alexa Fluor 647 labeled HCoV-HKU1 S1, to obtain a final concentration of 10 nM. For cross-reactivity measurements, anti-SARS-CoV-2 neutralizing antibody (SAD-S35, Acro Biosystems) was reconstituted according to the manufacturer's instructions. A four-fold dilution series, ranging from 60 pM to 1 µM was prepared by diluting into PBS, containing 0.05% Tween 20 and 5% human serum albumin (HSA). Antibody dilutions were subsequently mixed in a 1:1 ratio with a 20 nM solution of Alexa Fluor 647 labeled HCoV-HKU1 S1 or Alexa Fluor 647 labeled HCoV-NL63 S1 respectively, to obtain a final concentration of 10 nM. All samples were incubated for 1 h at 4 °C prior to measurement and kept at 4 °C throughout the experiment. Measurements were performed in triplicate using the 1.5-8 nm size-range setting on the Fluidity One-W Serum (Fluidic Analytics). The binding affinity, K D , was generated by non-linear least squares fitting to Equation 1 , leaving all parameters to be fit, but constrained to be >0. with R h , R h,free , and R h,complex being the average hydrodynamic radii of the reaction at equilibrium, of the unbound labeled S1 protein and of the complex of labeled S1 with unlabeled antibody, respectively. The parameters [U] 0 and [L] 0 are total concentrations of unlabeled antibody and labeled S1, respectively, and n is the number of binding sites per unlabeled antibody. Measurements of serum samples were performed as reported previously¹⁶. For the MAAP measurements, varying fractions of COVID-19 convalescent or pre-COVID serum samples were combined with Alexa Fluor 647 labeled antigen of varying concentrations ranging between 1 nM and 250 nM. Buffer was added to give a constant volume of 20 μL for each sample, followed by an incubation for 1 h at 4 °C. For MAAP against SARS-CoV-2 RBD, HCoV-NL63 RBD or HCoV-HKU1 RBD, PBS containing 0.05 % Tween 20 (pH 7.4) was used as a buffer. For profiling of serum against SARS-CoV-2 S1, SARS-CoV-2 S2, HCoV-NL63 S1 and HCoV-HKU1 S1, the buffer additionally contained 5% human serum albumin (HSA). Because of limited sample availability only a subset of the nine convalescent serum samples could be affinity profiled against HCoV-HKU1 RBD and HCoV-HKU1 S1 (Suppl. Figure 1 and Suppl. Table 3) . Following incubation, the hydrodynamic radius, R h , of the serum antibody -antigen complex was determined by microfluidic diffusional sizing using a Fluidity One-W Serum. Additionally, each serum was measured separately at a concentration of 100%, 50% and 25%, to allow correction of titration datapoints for the autofluorescence of the individual serum. The binding affinities and concentrations of antigen-specific antibodies in serum samples were determined by monitoring the fraction of labeled antigen that diffused into the distal chamber of the microfluidic device. Following background correction of samples to account for autofluorescence signal arising from the serum, this fraction can be determined by: ( Given that we monitor a mixture of free and bound (B) labeled species (L), I d and I u can be expressed as: where k is a constant that relates the concentration of L to the observed fluorescence intensity, [B] is the equilibrium concentration of bound L, and ρ f and ρ b are the fractions of free and bound labeled antigen that diffuse across to the distal channel, respectively. f d can thus be expressed as follows: By solving the binding equilibrium equation, [B] is given by: where [U] is the total concentration of antibody binding sites in the serum, and α is the fractional concentration of serum in the binding measurement. Bayesian inference was used to determine K D and [U], with a prior that was flat in logarithmic space for K D and [U], and flat in linear space for ρ f and ρ b . The likelihood was a Gaussian with mean f d and its standard deviation defined as the standard deviation of all measurements of each labeled antigen. As serum samples were derived from convalescent patients, potentially containing different classes of antibodies with variable numbers of binding sites (IgG = 2, IgM = 10), antibody concentration is expressed in terms of binding sites, rather than molecules. 10 nM Alexa Fluor 647 labeled HCoV-NL63 RBD in PBS containing 0.05% Tween 20 was combined with serum sample corresponding to a final anti-NL63 RBD antibody concentration of 20 nM (based on previous MAAP of each serum sample). For competition, unlabeled SARS-CoV-2 RBD was added at a concentration of 250 nM. Samples were incubated 1 h at 4 °C prior to equilibrium binding measurements using the Fluidity One-W Serum. Labeled HCoV-NL63 RBD in buffer, and a mixture of labeled HCoV-NL63 RBD with serum only served as controls. All measurements were performed in triplicate. For background correction, serum was diluted in PBS containing 0.05% Tween 20, at the same v/v concentration as used in the assay and measured separately. Background subtraction was applied to individual datapoints obtained in the assay. As part of constructing the dataset used in this research, we developed a series of procedures that we jointly refer to as "quality control (QC) pipeline". Firstly, they serve as simple sanity checks to ensure that data processing and model fitting was performed correctly. Secondly, they help identify problematic measurements, samples, or model fits. Based on this, decisions to re-collect or exclude parts of the data can be made. Finally, if assumptions about relationships in the dataset are appropriately tested, information can be shared between experiments and samples in a robust way, which improves model fitting. The detailed discussion of these methods is outside the scope of this publication; however, we are providing it in the form of a supplementary to this work, to serve as a guide for anyone performing similar analyses (Suppl. Material 1). When applying the described procedures to the present dataset, we identified a small number of outlier measurements. These were removed during the model fitting and data analysis step. Otherwise, the dataset passed all QC tests. Immune Response to SARS-CoV-2 and Mechanisms of Immunopathological Changes in COVID-19 Older Adults Lack SARS CoV-2 Cross-Reactive T Lymphocytes Directed to Human Coronaviruses OC43 and NL63 T Cell Response to SARS-CoV-2 Infection in Humans: A Systematic Review Cross-Reactive Serum and Memory B Cell Responses to Spike Protein in SARS-CoV-2 and Endemic Coronavirus Infection Human Coronaviruses and Other Respiratory Infections in Young Adults on a University Campus: Prevalence, Symptoms, and Shedding Human Coronavirus NL63 and 229E Seroconversion in Children First Infection by All Four Non-Severe Acute Respiratory Syndrome Human Coronaviruses Takes Place during Childhood Remembrance of Things Past: Long-Term B Cell Memory After Infection and Vaccination Humoral Immunity Due to Long-Lived Plasma Cells Antibody Dependent Enhancement Due to Original Antigenic Sin and the Development of SARS. Front. Immunol. 2020, 11 Molecular Mechanism for Antibody-Dependent Enhancement of Coronavirus Entry Cross-Reacting Antibodies Enhance Dengue Virus Infection in Humans. Science (80-. ) Modulation of Dengue/Zika Virus Pathogenicity by Antibody-Dependent Enhancement and Strategies to Protect against Enhancement in Zika Virus Infection The Possible Role of Cross-Reactive Dengue Virus Antibodies in Zika Virus Pathogenesis Microfluidic Antibody Affinity Profiling for In-Solution Characterisation of Alloantibody -HLA Interactions in Human Serum Microfluidic Affinity Profiling Reveals a Broad Range of Target Affinities for Anti-SARS-CoV-2 Antibodies in Plasma of Covid Survivors. medRxiv Vitro Measurements of Protein-Protein Interactions Show That Antibody Affinity Governs the Inhibition of SARS-CoV-2 Spike/ ACE2 Binding in Convalescent Serum. bioRxiv. bioRxiv Preexisting and de Novo Humoral Immunity to SARS-CoV-2 in Humans Cross-Reactive Antibody Responses against SARS-CoV-2 and Seasonal Common Cold Coronaviruses. medRxiv. medRxiv The Human Coronavirus HCoV-229E S-Protein Structure and Receptor Binding Conformational Transition of SARS-CoV-2 Spike Glycoprotein between Its Closed and Open States Spike Glycoprotein Conformation Antibody-Dependent SARS Coronavirus Infection Is Mediated by Antibodies against Spike Proteins Early Peak and Rapid Decline of SARS-CoV-2 Seroprevalence in a Swiss Metropolitan Region Absence of Severe Acute Respiratory Syndrome Coronavirus 2 Neutralizing Activity in Prepandemic Sera From Individuals With Recent Seasonal Coronavirus Infection Hosts and Sources of Endemic Human Coronaviruses Remembrance of Things Past: Long-Term B Cell Memory After Infection and Vaccination Seasonal Coronavirus Protective Immunity Is Short-Lasting Seasonal Coronavirus Protective Immunity Is Short-Lasting Anti-Prothrombin Autoantibodies Enriched after Infection with SARS-CoV-2 and Influenced by Strength of Antibody Response against SARS-CoV-2 Proteins Work performed by AA and ME was funded by institutional core funding by the University of Zurich and the University Hospital of Zurich, Driver Grant 2017DRI17 of the Swiss Personalized Health Network (SPHN), Distinguished Scientist Award of the NOMIS Foundation, a Grant of the European Research Council (ERC Prion2020 670958), and an Innovation Fund of the University Hospital Zurich. V.K. was funded by an NIHR fellowship (PD-2016-09-065) and acknowledges support as a PI Terasaki Scholar. T.P.J.K. is grateful for financial support by the Biotechnology and Biological Sciences Research Council and the European Research Council.