key: cord-0310803-7yiwlnsk authors: Kriegel, M.; Hartmann, A.; Buchholz, U.; Seifried, J.; Baumgarte, S.; Gastmeier, P. title: SARS-CoV-2 Aerosol Transmission Indoors: A Closer Look at Viral Load, Infectivity, the Effectiveness of Preventive Measures and a Simple Approach for Practical Recommendations date: 2021-11-04 journal: nan DOI: 10.1101/2021.11.04.21265910 sha: 44291a56bc6062b352f45cd0ffa6704150011e13 doc_id: 310803 cord_uid: 7yiwlnsk Currently, airborne transmission is seen as the most important transmission path for SARS-CoV-2. In this investigation, a classic dose-response model is used on the one hand to find out retrospectively the probable viral load of the infectious source patient at the time of transmission in 25 documented outbreaks. We showed that an infection due to airborne transmission at a distance from the infectious person was probably only possible in the 25 outbreaks examined, with attack rates of 4-100%, if the viral load had been higher than 1E+08 viral copies/ml. This demonstrates that the viral load estimated from the swab might overestimate a person's infectivity via aerosol, because a person is generally considered infectious, independent of the transmission way, when the viral load from the swab is 1E+06 viral copies/ml. On the other hand, a possible approach is presented to predict the probable situational Attack Rate (PARs) of a group of persons in a room through aerosol particles emitted by an infectious source patient. Four main categories of influence on the risk of infection are formed: First the emitted viruses, depending on the viral load and the amount of respiratory particles, and necessary number of reproducible viruses for infection, second the room-specific data and duration of stay of the group of people, third the activity of the exposed persons, and fourth the effect of personal protection (e.g. wearing masks from infectious and/or susceptible person). Furthermore, a simplified method is presented to calculate either the maximum possible number of persons in a room, so that probably a maximum of one person becomes infected when an infectious person is in the room, or the PARs,simple for a given number of persons, ventilation rate and time of occupancy. We additionally show, taking into account organizational preventive measures, which person-related virus-free supply air flow rates are necessary to keep the number of newly infected persons to less than 1. The simple approach makes it easy to derive preventive organizational and ventilation measures. Our results show that the volume flow rate or a person-related flow rate is a much more effective parameter to evaluate ventilation for infection prevention than the air change rate. We suggest to monitor the CO2 concentration as an easy to implement and valid measurement system for indoor spaces. Finally, we show that of the three measures, besides of wearing masks and increasing ventilation, testing contributes the most to the joint protective effect. This corresponds to the classic approach to implement protection concepts: preventing the source from entering the room and emitting viruses at all. In summary, a layered approach of different measures is recommended to mutually compensate for possible failures of any one measure (e.g. incorrect execution of tests, incorrect fit of masks or irregular window opening), to increase the degree of protection and thus reduce the risk of transmission of SARS-CoV-2. organizational preventive measures, which person-related virus-free supply air flow rates are 24 necessary to keep the number of newly infected persons to less than 1. The simple approach 25 makes it easy to derive preventive organizational and ventilation measures. Our results show 26 that the volume flow rate or a person-related flow rate is a much more effective parameter to 27 evaluate ventilation for infection prevention than the air change rate. We suggest to monitor 28 the CO2 concentration as an easy to implement and valid measurement system for indoor 29 spaces. 30 Finally, we show that of the three measures, besides of wearing masks and increasing 31 ventilation, testing contributes the most to the joint protective effect. This corresponds to the 32 classic approach to implement protection concepts: preventing the source from entering the 33 room and emitting viruses at all. In summary, a layered approach of different measures is 34 recommended to mutually compensate for possible failures of any one measure (e.g. incorrect 35 execution of tests, incorrect fit of masks or irregular window opening), to increase the degree 36 of protection and thus reduce the risk of transmission of SARS-CoV-2. 37 The air change rate can be calculated regarding equation (1) as the ratio of the volume flow 64 (Q) to the room volume (V). 65 (1) Typical air change rates for indoor environments range between 0.5 1/h for residential 66 buildings and 8 1/h for occupied rooms with several attendants like meeting rooms in offices 67 [6] . Often an air change rate of 6 air changes per hour is recommended to minimize the risk of 68 infection [7] . Therefore, the air change rates advised for hospitals are used [6, 8] . 69 Nevertheless, these recommendations are not based on infection prevention, but on CO2-70 emission of room occupants as well as general air quality requirements or thermal loads 71 within the room. 72 The deposition rate for particles depends on their size, the air velocity, the turbulence 73 intensity of the air movement and the ratio of surface area to room volume [9, 10, 11] . 74 Thatcher et al [10] investigated the deposition of particles on surfaces depending on the room 75 furniture and the air speed. The deposition rate increased for larger particles, higher air speed 76 or an increased surface area of furniture. Particles between 0.55 and 8.66 µm were considered 77 in this study . 78 Similar results were also found by Offerman [11] , but for somewhat smaller particles 79 (between 0.09 and 1.25 µm). Still the deposition rate increased for larger particles. For 80 particles between 0.3 and 5 µm, which is considered to be the most important size range for 81 airborne particles in equilibrium state, which will stay in air for a long time and are able to 82 carry viruses, the deposition rate ranges between 0.1 and 0. 4 1/h. 83 temperature was found to be much larger than the influence of humidity, still all aspects have 114 significant influence on the decay rate. 115 In 1978, Riley et al. [22] evaluated a measles outbreak in a suburban elementary school. 116 Based on the number of susceptible persons (S), which have been infected (D) during each 117 stage of infection of the source patient, the risk (P) for an infection at this stage has been 118 calculated using equation (2) . The risk for an infection has been defined as the percentage of 119 infected persons from the number of pupils not already infected or vaccinated. 120 A Poisson-distribution of the risk of infection has been assumed as well as a stationary and 121 evenly distributed concentration of the pathogens in the room air. Equation (3) shows the 122 Poisson-distribution. 123 In 1955 Wells [23] defined a size called quantum as the number of emitted infectious units, 124 where the probability to get infected is 1 − −1 = 63.2%. Hence, a quantum can be seen as a 125 combination of the amount of emitted virus-laden aerosol particles and a critical dose, which 126 may result in an infection in 63.2 % of the exposed persons. The quantum concept as well as 127 equation (3) was combined by Riley [22] to equation (4) . 128 In equation (4) , the relevant parameters are integrated. The probability of infection rises with 129 the number of infectious persons (I), the quanta emission rate depending on the activity (q), 130 the pulmonary ventilation rate of exposed susceptible persons (Qb,in), the duration of stay (t), 131 but is inversely related to the air change rate ( ) and the room volume (V). 132 Equation (5) can be used to calculate the individual risk of infection depending on the ratio of 133 the number of inhaled viral copies N and the number of viral copies necessary to result in an 134 infection N0 [24] . 135 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint = 1 − − / 0 (5) The probability P in equations (2) to (5) can be seen as the individual risk of infection Pind. 136 If it is assumed, that statistically in a group of susceptible persons (NPers) exactly this 137 percentage of people is getting infected we define the attack rate (AR) in a given situation as 138 the situational Predicted Attack Rate PARS (see equation (6)). 139 = (6) In poorly ventilated rooms, the assumption of a steady concentration of virus copies is often 140 not fulfilled. The normalized time-dependent concentration process can be calculated 141 according to equation (7) and is shown in Figure 1 , assuming that the particles are 142 immediately distributed uniformly in the room [25] . How rapidly the concentration of a 143 person emitted contamination in a room rises depends on the overall lambda (λg) and the time 144 (t). Overall lambda thereby consists of the air change rate as well as the decay rates because 145 of sedimentation and inactivation. The relative concentration (crel) based on the steady-state 146 concentration can be seen as an increase in the concentration compared to the volume flow. 147 148 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint In many published studies that use the Wells-Riley equation to determine infection risk ideal 152 mixing ventilation was assumed, which means that particles are evenly distributed in the room 153 air immediately after emission. It should be considered that local concentration differences 154 will occur in the room and that the viral load in the room areas will vary widely [26, 27, 28] . 155 To estimate the risk of infection in a given setting by a given infectious person with the 156 Wells-Riley-equation the quanta emission rate (q) has to be known. In various studies of 157 infection occurrences associated with SARS-CoV-2, q was determined using the Wells-Riley 158 equation retrospectively. Different authors [29, 30] found a range of 36 to 62 quanta/h with an 159 assumed low activity (breathing, speaking) and values of 341 to 1190 quanta/h when singing. 160 Furthermore, Buonanno et al. [31] as well as Bazant [32] used the viral load measured in the 161 sputum of infected persons to calculate q for different activities. Therefore, emission rates for 162 different activities (breathing volume flows, particle emission) as well as different states of 163 infection (viral load in the sputum) can be calculated. A model, which applies this approach 164 was set up by Lelieveld et al. [33] . 165 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint In measurements of different research groups [34, 35, 36, 37, 38] the particle emission rates 166 during breathing, speaking, coughing as well as singing were measured. During breathing 167 through the nose between 25 particles/s [35, 37] and 135 particles/s [36] was emitted and 168 during coughing about 13,700 particles/cough [35] , whereas it can be seen that depending on 169 the activity a wide range of particle emission rates can be found. The particle emissions while 170 speaking and singing depended on the loudness of the activity, but in most cases the emission 171 rates was found to be higher for singing than for speaking. Whereas for normal speaking the 172 emission rates ranged between 30 particles/s [37] and 270 particles/s [36, 35] , for singing it 173 ranged approximately between 100 particles/s [37] and 2000 particles/s [34, 39] . 174 In all five studies [34, 35, 36, 37, 39] regarding the particle emission rate of adults at least 175 99 % of the measured particles were smaller than 3.0 µm. In Alsved et al. [36] and Gregson et 176 al. [37] 60 % of the particles were even smaller than 1.0 µm, whereas in Hartmann et al. [35] 177 as well as Mürbe et al. [34] even 85 % of the particles were smaller than 1.0 µm and 60 % 178 smaller than 0.5 µm. The particle emission rates measured by some of the authors are shown 179 in Figure 2 and is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint 181 Figure 2 : particle emission rates measured by some of the authors, for adults: [31, 36, 32] , 182 for adolescents [35] and for children [38] 183 Smaller particles remain airborne for a long time. The viral load (copies/ml) is aerosolized in 184 the respiratory tract and not every small particle carries one virus. The larger the particle size, 185 the higher the number of particles that actually carry a virus. Nevertheless, the measured 186 particle size is the equilibrium size after evaporation. In different studies, a particle reduction 187 to between 33 and 50% [40] of the original size was measured. 188 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The results of the investigation of the filter efficiency of different materials were reviewed by 197 Kwong et al. [41] . For example, for microfiber the filter efficiency ranged from 10 to 75% 198 and for cotton/synthetic mix from 5 to 45%. The authors discuss that the materials have to be 199 described with more details to make it possible to compare different studies. 200 Karuppasamy and Obuchowski [42] as well as Mueller et al. [43] investigated the influence if 201 masks worn more tightly to the face. Whereas Karuppasamy and Obuchowski [42] found an 202 improvement with surgical face masks, fixed with medical tape to the face of health care 203 workers, Mueller et al. [43] found a reduced emission if the masks are tighter by using a 204 nylon stocking to fix a cotton mask. The research group of Asadi et al. [44] and Cappa et al. 205 [45] investigated the particle emission rate for different activities as well as different mask 206 types. They found that the overall particle emission rate (through the mask as well as through 207 leakages) is about 90% lower for coughing and 70% lower for talking compared to the case 208 without masks. Still, this cannot be applied for cotton masks, where sometimes higher particle 209 emission rates were measured with mask than without mask. In case of a reduction, especially 210 larger particles were found to be reduced. 211 In a study by some of the authors [46] the ratio of air leaking around the edges of the masks 212 while exhaling was measured. The leakage ranged between 20 and 90% for cotton masks, 213 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint on the viral load is given as 96 % for more than 1E+07 viral copies/ml, 92 % for 1E+04 to 250 1E+07 viral copies/ml and 43 % for lower viral loads. The value for the highest viral load was 251 also confirmed by e.g. Lindner et al. [59] , but seems pretty high for the other groups 252 compared to the values found in the aforementioned studies. In most cases, where the infected 253 person was not detected with the rapid test, the viral load was lower than 1E+06 viral 254 copies/ml. In [61] it was shown that suitable test kits have a sensitivity of 80% compared with 255 RT-PCR at a viral load of 1E+06 viral copies/ml. Even the lowest sensitive test showed a 256 90 % probable detection rate at a viral load of 2.3E+07 viral copies/ml. Similar orders of 257 magnitude were found in [62] . Of 122 rapid antigen tests investigated by Scheiblauer et al. 258 [63] 96 passed a limit of 75 % sensitivity at a viral load of 1E+06 viral copies/ml. No 259 significant change in the test sensitivity for the VOC was found [64, 65] . In a model [66] as 260 well as a longitudinal study [67] it was shown, that rapid antigen tests are able to detect 261 infected persons during the course of an infection and may therefore reduce the transmission 262 [66] if performed at a regular frequency [67] . Whereas the viral load can increase by a factor 263 of about 100 within 24 h before symptom onset/peak viral load [13] . Rapid antigen tests will 264 detect an infection only within the diagnostic window around the highest peak of infection. It 265 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint shown in [68] , that students who had close contact with a classmate who tested positive for 270 SARS-CoV-2 and were subsequently tested daily avoided days absent from school, with no 271 impact on overall infection incidence. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint In the following consideration, two different cases, one stationary and one time-dependent, 290 are taken into account. For unsteady situations, it is assumed that the infected person enters 291 the room at time 0 and the concentration in the room increases until a steady state is reached 292 (see Figure 1 ). 293 The number of inhaled particles Ninh in equation (5) can be described with the help of 294 equation (8) . SV is thereby the viral-emission rate in viral copies/time and • is the viral 295 concentration per cubic meter of air. The overall lambda consists of the air change rate (ACH 296 = ACH), the decay rate because of inactivation (in) and the decay rate because of 297 sedimentation (sed). 298 Finally, equation (11) can be set up. 299 If face masks are used, the number of inhaled particles Ninh can be reduced. This reduction 300 can be implemented into equation (11) as factor fM, which will result in equation (12) . 301 For the unsteady calculation, the course of the virus concentration is used according to 302 equation (7) . Equation (5) therefore transforms into equation (13) and equation (4) into 303 equation (14) . 304 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The emission rate of virus laden particles depends on the activity, which influences the 316 number of emitted particles as well as their size distribution. Furthermore, the viral load 317 influences the number of virus carried on one particle. The emission rate Sv can therefore be 318 described as the product of the particle emission rate , a factor considering their size 319 distribution fp and the viral load nv (see equation (18)). 320 Thereby fp describes a conversion factor from the particle emission rate per second to their 321 volume emission rate per hour and depends on the size distribution. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint N0 is assumed to be in the range of 100 to 300 viral copies [24] . The virus related factor is 325 defined in equation (17) . 326 In the situational factor the boundary conditions for the specific situation are considered. It 328 therefore consists of the room volume VR, the overall lambda ( ) as well as the time of stay 329 (t). In a steady state it can therefore easily be derived from equation (12) and will result in 330 equation (19) . For an unsteady situation the equation for the concentration (see Figure 1 and 331 equation (20)) has to be integrated to get equation (21) . 332 3. Susceptible person-related factor (SPF) 333 As mentioned in the state of the arts the breathing volume flow depends on the activity of the 334 persons. Furthermore, it can be split up into the exhalation flow rate (Qb,ex) of the infected 335 person and the inhalation flow rate (Qb,in) of the susceptible persons. To calculate the number 336 of inhaled particles, just the inhaled volume flow rate (Qb,in) has to be considered. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint efficiencies, whereas fm,e as well as fm,in is the ratio of particles going by the mask or the 346 difference between 1 and the ratio of particles separated by the mask. 347 Equation (13) can therefore also be expressed as: 348 For the calculation of PARs the following assumptions must be considered: 349  the aerosol is ideally mixed in the room 350  the near field can contain a much higher virus-laden particle concentration, but it is 351 neglected in the following 352  the air, which is introduced into the room, is free of virus-laden particles 353  a constant decay rate of deposition occurs (in this consideration = 0. consideration. In addition, the outbreaks either had to be attributed to the wild-type of SARS-362 CoV-2 (e.g. by sequencing) or had occurred before 01.01.2021. Smaller outbreaks provided 363 by local health authorities are included if they meet the same criteria. The description of the 364 outbreaks as well as the boundary conditions for the calculations of these situations can be 365 found in the appendix and in Table 3 . The values were either taken from the publication or 366 calculated from data given in them. Some data is due to better documentation more secured, 367 whereas other values are somewhat less certain, a variance of the values is assumed. A normal 368 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint distribution of the values characterized by the mean value and the standard deviation (given as 369 the variance) was assumed. A Monte-Carlo-Simulation was used to randomly combine values 370 from within this range for the calculation of the outbreaks [69] . Therefore, a conclusion can 371 be drawn, about the reliability of the calculated values and their variance evoked by the 372 uncertain boundary conditions. The outbreaks can be separated into different categories: choir 373 rehearsals (4 outbreaks), outbreaks with higher physical activity (4 outbreaks), meetings with 374 lower activity, but many people (3 outbreaks), outbreaks in public transport (6 outbreaks) and 375 smaller outbreaks, which are sometimes not scientifically published, but investigated by local 376 health authorities (8 outbreaks (19)) and unsteady 382 (regarding equation (21))), fM and Ob,in can be seen in Table 1 . 383 We compared the results from the retrospective investigation with available data regarding the 384 viral load and the particle emission. Therefore, in Figure 3 and Figure 4 the ratio of the viral 385 emission and the critical dose ( / 0 ) are presented over the viral load and the particle 386 emission. The colors visualize the AR from the investigated outbreaks, whereby the single 387 outbreaks are shown as dots. A mean particle emission rate as a function of activity was 388 assumed when plotting the dots, according to Figure 2. In Figure 3 the critical dose N0 is 389 assumed to be the minimal value of 100 viral copies and in Figure 4 a higher value of 390 300 viral copies, both related to [24] . With a higher critical dose, the lines with similar PARs 391 are shifted upwards, whereas either a higher viral load or a higher particle emission rate is 392 necessary to result in the same PARs. It can be seen that the viral load for all investigated 393 outbreaks had to be higher than 1E+08 viral copies/ml to explain the outbreaks with the given 394 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint boundary conditions. If instead of equation (21) for time-depended calculation, equation (19) 395 for steady-state assumption is used, the values 0 are lower than the values calculated 396 for the unsteady conditions. Nevertheless, the viral load had to be higher than 1E+08 viral 397 copies/ml to reach the ARs (see Table 1 ). 398 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint 22 As it is mentioned in Table 3 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint (standard deviation ± 20 %) and insecure or unknown (standard deviation ± 50 %) for each 412 outbreak as it is displayed in Table 3 in red. To take these uncertainties into consideration a 413 Monte-Carlo-Simulation with 10,000 simulations for each outbreak is performed. The 414 investigated aspects (air change rate, room volume, number of infected persons, if it cannot be 415 secured, that it was just one person, breathing volume flow, time of stay and attack rate) are 416 assumed to be normally distributed with the given value as mean and the assumed level of 417 security as standard deviation. Furthermore, limits for the AR, lower than 100% and the other 418 aspects larger than 0, are considered. The median as well as the 25 %-percentile and the 419 75 %-percentile are displayed in Table 1 . is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. This equation can be transformed into equation (26) . 442 For the simplified calculation, a steady state situation is assumed. CR,s can therefore be 443 replaced by equation (19) . 444 In the following, it is assumed that the air change rate is the dominant variable within 445 equation (10) . This is valid whenever non-residential standards and guidelines (DIN / 446 ASHRAE) are respected. Therefore ≈ can be assumed. Taking equation (28) into 447 account, equation (29) is obtained, with qPers the specific volume flow (person-related volume 448 flow) in m 3 per hour and person. 449 The following simplified method can easily be used in situations, where not more than one 450 person shall be infected and therefore RS = 1 and therefore no outbreak would probably 451 happen due to aerosol transmission (definition of outbreak: more than one person get infected 452 during transmission event). In rooms with number of susceptible persons is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint Further on, (30) can be converted into equation (31) to calculate the specific volume flow of 456 virus free air to fulfill RS = 1. 457 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint For the yellow and orange area short times of stay or further measures have to be considered 471 to keep the number of newly infected persons below one (RS  1), whereas a much higher air 472 supply is necessary. The volume flows in the red area cannot be reached in rooms with 473 common airflow rates. 474 475 Instead of a specific volume flow per person a specific volume per person (VPers) can be 476 used together with the overall lambda (λg) to convert equation (31) into equation (33) . 477 From this equation it can easily be seen that recommending an air change rate alone, e.g. Equations (35) and (36) can be used to comparatively evaluate different situations in indoor 490 environments as well as preventive measures. Therefore, a risk factor xr can be defined 491 according to equation (37) . If the VF remains the same in the rooms being compared 492 (identical virus variant), then the risk factor depends on SF, SPF, and PPF only. . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. In Figure 6 same everyday life situations are compared to a 0.5 hour stay in a supermarket 498 with mask, using equation (37) . The details for these exemplary considerations can be found 499 in the appendix, table 4. 500 501 Influence of Variants of concern (VOC) 502 For example, if the transmission rate doubles and this is not caused by a change in behavior 503 (SF, SPF, or PPF), then it is due to the change in the VF. Here, either the necessary critical 504 dose or the viral load or both may have shifted. The influence of the critical dose and Sv/N0-505 ratio to the PARs is shown in Figure 7 . 506 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint 507 508 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint air volume flow and the preventive impact. To wear a face mask will on average reduce the 536 inhaled dose by 50 %, whereas a factor of 2 can be applied as well as for halving the time of 537 stay in the room together with the infectious person. For a FFP2-mask the dose will, in 538 average, be reduced by 80 %, whereas a factor of 5 can be applied. 539 From Figure 10 it can be seen, that even with a combination of different measures an outbreak 540 cannot be avoided completely, and infections may occur, if the viral load is high enough. 541 Only a small change in viral load with a factor of 10, e.g. from 1E+08 to 1E+09, could 542 probably be compensated by wearing masks and ventilate regularly (Figure 10 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint A dose-response-model to evaluate the risk of infection with SARS-CoV-2 was used to 552 analyze twenty-five outbreaks in different situations (e.g. school, choir, meetings). 553 Although the viral load in the investigated outbreaks were unknown, our results strongly 554 suggest that relevant transmission will take place when viral loads are high. Data of particle 555 emission rate during various activities were used to infer virus emission rate, but this varies 556 significantly among individuals (Figure 2 ). Even if the particle emission is significantly 557 under-or overestimated, a viral load of at least 1E+08 viral copies/ml would have to be 558 existent (see Figure 3 and Figure 4 ). Using this particle emission rate and size distribution, a 559 number of aerosolized viruses is obtained as a function of viral load. It is assumed that the 560 viruses at the site of aerosol generation in the body corresponds to the viral load in the swab, 561 which remains to be proven. 562 The highest calculated value is found for a choir rehearsal with 0 = 2,529 1 ℎ and is therefore 563 within the range found by Buonanno et al [31] . The lowest value of 0 = 36 1 ℎ is found for a 564 bus travel, where the activity and/or the viral load might have been low, which is comparable 565 to the results of Buonanno et al [31] as well. The high emission during the choir rehearsal 566 seems valid, because of the high particle emission rates while singing and the low air change 567 rate. Furthermore, it has to be taken into consideration that the particle emission for different 568 persons might be different for the same activity so the 0 can be quite different, but still the 569 main conclusion will remain. 570 Regardless of the claim for correct quantity of particle emission strength and viral load, it was 571 shown that the specific person-related airflow rate is a practical quantity for evaluating 572 ventilation-related measures, simply mathematically derived, see (24) - (32) . 573 It has also been clearly demonstrated by us that preventive ventilation measures can prevent 574 outbreaks due to aerosol transmission only in a narrow band. At high virus loads, the outbreak 575 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint size can be reduced, but not prevented. Additional preventive measures are often necessary 576 ( Figure 5 , Figure 9 and Figure 10) . 577 If the viral load must be so high to cause infection due to aerosol transmission, then even 578 using Ag Tests can be very effective measure to prevent infectious individuals from entering 579 the room and causing an outbreak. Nevertheless, their efficiency depends on quite a lot of 580 influencing factors, like the quality (sensitivity) of the test and the correct execution of the 581 test. Even if studies showed that in general, most pupils are able to perform the Ag-tests 582 correctly if instructed, a repetition on regular basis may e.g., result in less attention paid to 583 correct testing. Also, if antigen tests are not carried out on a daily basis, the possibility exists 584 that a person with a positive test result already exhibited transmissible virus loads the 585 previous day. 586 However, different limitations as well regarding the model as the practical application have to 587 be considered. First of all, different influencing factors (e.g. critical dose, decay rate of 588 sedimentation as well as inactivation, size distribution and number of emitted particles) were 589 assumed based on current knowledge, but whereas the transmission of SARS-CoV-2 is still 590 ongoing, further knowledge may be gained from further research. The decay rates of 591 sedimentation as well as inactivation can be influenced by the particle size distribution as well 592 as the air temperature and humidity in the room. Furthermore, the analysis and model base on 593 some general assumptions like ideal mixing of all particles within the room, an initial 594 concentration of 0 virus copies/m³ and a supply of virus free air. An ideal mixing of all 595 particles in the room also implies, that no separation into near and far field can be performed, 596 whereas the concentration of virus laden particles near the person is probably higher than in 597 the rest of the room. Also, the local concentration will differ regularly from the average 598 concentration so that the local air quality index should be considered for investigations in 599 detail [27, 28] . As a result, even at lower viral emission rate Sv, infection can occur via 600 aerosol, predominantly in the near field. As a third aspect the influence of VOCs is difficult to 601 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint define. A higher transmission rate of new VOCs may result from different aspects, such as a 602 change in critical dose, a change in viral load or a change in other measures. It also has to be 603 kept in mind, that the investigated outbreaks documented with ARs between 4 % to 100 % 604 have had mostly high ARs and therefore result in a high number of newly infected persons. 605 Many transmission events have much lower ARs, so the results may over-or understate the 606 true risk. 607 It could be shown that for viral loads smaller than 1E+08 viral copies/ml, aerosol transmission 608 becomes unlikely if the distance is maintained. But it has to be considered that in some of the 609 investigated cases, the range between the 25 % and the 75 %-percentile is quite high, which is 610 because of insecure boundary conditions. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint Ag tests bring an effective additional value: they have a high sensitivity (detection 627 rate) at virus loads of more than 1E+06 viral copies/ml and are therefore able to 628 detect infectious persons with a chance to isolate them before entering a room for 629 a longer stay. 630 From the investigation of the outbreaks, it can be concluded that in all cases a viral load of at 631 least 1 + 08 have been necessary to reach the observed attack rates. It can be 632 seen that the viral emission of the infected person is the dominant influencing factor, but three 633 further aspects (situational aspects, personal aspects of the susceptible persons and preventive 634 measures) have to be considered to transfer a transmission of SARS-CoV-2 into a 635 superspreading event. It can be concluded that solely a high activity (like singing or physical 636 activity) does not necessarily result in high ARs (Choir Rehearsal Berlin 2) and that lower 637 activity may also result in high ARs (e.g. School Hamburg 1) if other unfavorable conditions 638 (e.g. high viral load, ineffective preventive measures) occur. 639 Nevertheless, a higher activity will result in a higher emission rate of particles and therefore 640 in a higher concentration of virus laden particles in the room air. For transmission, aerosol 641 production and viral load must always be considered together. A person considered infectious 642 does not mean that aerosol transmission will also occur. 643 The comparison of different preventive measures demonstrates that these measures alone as 644 well as in combination are able to reduce the rate of transmission, but for high viral loads still 645 high infection rates will occur. Especially with the VOC Delta, for which an up to 1,000-times 646 higher viral load was found for persons, there is a high risk of outbreaks and superspreading 647 events even when the AHA+L rules are observed (German Abbreviation for masks, hand 648 hygiene, social distancing and ventilation). 649 We showed, that to recommend an air change rate alone is not sufficient for infection 650 prevention, whereas the person related volume flow of virus free supply air is a much more 651 relevant parameter. The specific volume flow per person can be correlated with a CO2-652 . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint The authors received no specific funding for this work. 680 The authors declare no competing interests. 681 The authors declare that they followed the appropriate research guidelines. . CC-BY 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint Appendix Calculation of the conversion factor from number to volume of the particles In different studies, the particle emission rate for different activities was measured. The results 683 found by some of the authors of this paper can be seen in Table 2 . It has to be mentioned that 684 the particles were measured about 0.81 m behind the mouth of the subjects. Therefore, it was 685 assumed that they already reached equilibrium diameter, when entering the particle counter. To 686 take this into consideration the evaporation has to be considered. Regarding [40] it is considered 687 that the equilibrium diameter is between 33 and 50% of the original diameter. 688 689 [34, 39, 35] , for adolescents in [38] 690 and for children in [72] is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint To calculate the conversion factor from the particle emission rate to the volume of the particles first of all the volume of a particle has to be calculated. Spherical particles were assumed for this calculation. Furthermore, for each size class the minimum diameter is assumed to be most representative, because more smaller than larger particles were found. With this assumption the volume of the particles in the different size classes can be calculated with a shrinking factor of 2 so a particle with a diameter of 0.3 µm, was calculated with an initial diameter of 0.6 µm. The average emission of volume by exhaling one particle can therefore be calculated using 695 equation (38) where i denotes the size class, fi the proportion of particles in the size class and 696 Vi the volume of particles in this size class. 697 For breathing the exhaled volume of particles is therefore ℎ, = 3.20 • 10 −12 . The 698 conversion factor shall further include the conversion from seconds to hours and is therefore 699 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. In the Choir Rehearsal Berlin 2 the previously infected person was the choir director and was therefore not singing the whole time. Therefore, a mixture of singing and speaking was assumed [39] . In the French Choir three members of the choir got tested positive for SARS-CoV-2 within the next days after the rehearsal [73] . Although one member had symptom onset the day after the rehearsal it seems reasonable to assume that only one person emitted the virus laden particles. The second group consists of outbreaks either involving loud speaking or intense physical activity like sports or heavy working. For three out of the four outbreaks little information regarding the ventilation system in the room are available, so that typical values have been assumed, either by the authors of this study (Hawaiian fitness class [74] ) or by authors of earlier studies (Korean Call Center and Korean fitness center [30] ). Solely for the German Slaughterhouse measurements of the volume flow were performed afterwards [75] . is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint For the working places (call center [76] and slaughterhouse [75] ) the time of stay was a working day (8 hours) whereas for the fitness class the duration of stay was significantly smaller (approximately 1h or less [74, 77] ). Two outbreaks with normal office activity, but relatively high attack rates are considered as well [78, 79] . One outbreak happened during a school day (4.5 h) in a ventilated classroom [78] and the other during a court session (3 h) in an unventilated courtroom [79] . Both rooms had a similar size. Furthermore, an outbreak in a restaurant was included into this category. It is one of the first documented outbreaks related to airborne transmission of SARS-CoV-2. The boundary conditions, mainly room volume and ventilation were assumed by Li et al [1] . In addition, some outbreaks related to public transport were found [80, 81, 82, 83] . One Finally, two meetings as well as six outbreaks in school classes, which were investigated and provided by local health authorities, or the Robert-Koch-Institute are considered. For the outbreaks, the air change rate has either been assumed afterwards depending on the ventilation habits and the temperature and wind speed on the day of outbreak or known from existing ventilation systems. The room volume, the number of attending persons as well as the time of stay was investigated by the health authorities together with the attack rate reported for this outbreak. The index person in two of the school cases (School Hamburg 3 and School Hamburg 4) wore a mask (fM=0.7) and noted some symptoms, whereas he reduced speaking intensity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint ++ ±5% + ±20% + ±20% ++ ±5% + ±20% + ±20% ++ ±5% * 3 persons had contact to a later on positive tested person, but just one person had symptom onset on the day after the rehearsal ** transmission occurred just in a volume of 600 m³ *** area given, height of 3m assumed Evaluation of the security of the boundary conditions ++ quite secure, + a bit insecure, 0 unknown/insecure, assumed level of deviation 704 ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% Evaluation of the security of the boundary conditions ++ quite secure, + a bit insecure, 0 unknown/insecure, assumed level of deviation * exhalation/inhalation breathing volume flow To compare different situations with the simplified approach a viral load of 1E+08 viral 707 copies/ml was used. The situation in the supermarket with mask, like it is currently common, 708 where = 1 is used as the reference. In all situations the duration of stay is longer than in 709 the supermarket, but in the theater/cinema scenario the risk is lower than in the supermarket. 710 In all other situations the risk is higher and if the duration of stay is much longer (office or 711 school) the risk is significantly higher and further measures (reduction of the number of 712 persons in the room, wearing masks) are necessary to reduce the risk. 713 714 is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted November 4, 2021. ; https://doi.org/10.1101/2021.11.04.21265910 doi: medRxiv preprint Evidence for probable aerosol transmission of SARS-CoV-2 in a poorly ventilated restaurant Airborne route and bad use of ventilation systems as non-neglible factors in SARS-CoV-2 transmission Quantifying SARS-CoV-2 transmission suggests epidemic control with digital contact tracing Ten scientific reasons in support of airborne transmission of SARS-CoV-2 Transmissibility and transmission of respiratory viruses Empfehlungen zum erforderlichen Luftwechsel in Schulen, Großraumbüros, Härsälen und Turnhallen zur Reduktion eines aerosolgebundenen Infektionsrisikos Einfluss der Turbulenz einer Verdrängungsströmung in Operationsräumen auf Transport und Sedimentation von Mikroorganismen Effects of room furnishings and air speed on particle depositon rates indoors Control of Respiratory Particles in Indoor Air with Portable Air Cleaners Virological assessment of hospitalized patients with COVID-2019 Estimating infectiousness throughout SARS-CoV-2 infection course Just 2% of SARS-CoV-2−positive individuals carry 90% of the virus circulating in communities Daily sampling of early SARS-CoV-2 infection reveals substantial heterogeneity in infectiousness Viral infection and transmission in a large, well-documented outbreak caused by the SARS-CoV-2 Delta variant Virological and serological kinetics of SARS-CoV-2 Delta variant vaccine-breakthrough infections: a multi-center cohort study Outbreak of SARS-CoV-2 Infections, Including COVID-19 Vaccine Breakthrough Infections Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1 The influence of temperature, humidity, and simulated sunlight on the infectivity of SARS-CoV-2 in aerosols Airborne Spread of Measles in a Suburban Elementary School Airborne contagion and air hygiene: an ecological study of droplet infections Review of infective dose, routes of transmission and outcome of COVID-19 caused by the SARS-CoV-2: comparison with other respiratory viruses Adequacy of air change rate as the sole indicator of an air distribution system's effectiveness to mitigate airborne infectious disease transmission caused by a cough release in the room with overhead mixing ventilation: A case study REHVA-Guidebook Pathogen spread and air quality indoors -ventilation effectiveness in a classroom Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event Superspreading Events Without Superspreaders: Using High Attack Rate Events to Estimate N0 for Airborne Transmission of COVID-19 Estimation of airborne viral transmission: Quanta emission rate of SARS-CoV-2 for infection risk assessment A guideline to limit indoor airborne transmission of COVID-19 Model Calculations of Aerosol Transmission and Infection Risk of COVID-19 in Indoor Environments Aerosol emission is inscreased in professional singing of classical music Emission rate and particle size of bioaerosols during breathing, speaking and coughing Exhaled respiratory particles during singing and talking Comparing Aerosol Concentrations and Particle Size Distributions Generated by Singing, Speaking and Breathing Aerosol emission of adolescents voices during speaking, singing and shouting Analysis of Two Choir Outbreaks in Germany in 2020 Characterizes Longrange Transmission Risks Through SARS-CoV-2 Modeling evaporation and dispersion of airborne sputum droplets expelled from a human cough Review of the Breathability and Filtration Efficiency of Common Household Materials for Face Masks Comparison of Fit for Sealed and Loose-Fitting Surgical Masks and N95 Filtering Facepiece Respirators Quantitative Method for Comparative Assessment of Particle Removal Efficiency of Fabric Masks as Alternatives to Standard Surgical Masks for PPE Efficacy of masks and face coverings in controlling outward aerosol particle emission from expiratory activities Expiratory aerosol particle escape from surgical masks due to imperfect sealing Experimentelle Untersuchung der Leckage und Abscheideleistung von typischen Mund-Nasen.Schutz und Mund-Nasen-Bedeckungen zum Schutz vor luftgetragenen Krankheitserregern Zur Frage des geeigneten Atemschutzes vor luftgetragenen Krankheitserregern Effectiveness of Face Masks in Preventing Airborne Transmission of SARS-CoV-2 Characterizing exhaled airflow from breathing and talking Respiratory flows as a method for safely preventing the coronvirus transmission (COVID-19) The measurement of airflow using Singing helmet that allows free movement of the jaw Estimation of respiratory colume from thoracoabdominal breathing distances: comparison of two models of machine learning Breathing Pattern and kinematics in normal subjects during speech, singing and loud whispering Lexikon der Biologie," spektrum.de Asymptomatic rapid testing for SARS-CoV-2 Evaluation of two rapid antigen tests to detect SARS-CoV-2 in a hospital setting The potential of SARS-CoV-2 antigen-detection tests in the screening of asymptomatic persons Head-to-head comparison of SARS-CoV-2 antigen-detecting rapid test with self-collected anterior nasal swab versus professional-collected nasopharyngeal swab Diagnostic accuracy and feasibility of patient self-testing with a SARS-CoV-2 antigen-detecting rapid test Asymptomatic testing for SARS-CoV-2 using antigen-detecting lateral flow devices Establishment of an evaluation panel for the decentralized technical evaluation of the sensitivity of 31 rapid detection tests for SARS-CoV-2 diagnostics Comparison of severn commercial SARS-CoV-2 rapid Point-of-Care Antigen tests Comparatie sensitivity evaluation for 122 CE-marked SARS-CoV-2 antigen rapid tests In vitro and clinical post-market surveillance of Biotime SARS-CoV-2 Lateral Flow Antigen Device in detecting the SARS-CoV-2 Delta variant Detection of the new SARS-CoV-2 variants of concern B.1.1.7 and B.1.351 in five SARS-CoV-2 rapid antigen tests (RATs) The Effectiveness of Strategies to Contain SARS-CoV-2: Testing, Vaccinations, and NPIs Longitudinal assessment of diagnostic test performance over the course of acute SARS-CoV-2 infection Daily testing for contacts of individuals with SARS-CoV-2 infection and attendance and SARS-CoV-2 transmission in English secondary schools and colleges: an open-label, cluster randomised trial Monte Carlo and Quasi-Monte Carlo Sampling School education during the SARS-CoV-2 pandemic -Which concept is safe, feasible and environmentally sound? Indoor Air Changes and Potential Implications for SARS-CoV-2 Transmission Vergleich der Aerosolpartikelemissionen von Grundschulkindern und Erwachsenen beim Atmen, Sprechen, Singen und Rufen High Rate of SARS-CoV-2 Transmission Due to Choir Practice in France at the Beginnung of the COVID-19-Pandemic Community Transmission of SARS-CoV-2 at Three Fitness Facilities -Hawaii Investigation of a superspreading event preceding the largest meat processing plant-related SARS-Coronavirus 2 outbreak in Germany Cluster of Coronavirus Disease Associated with Fitness Dance Classes, South Korea A large COVID-19 outbreak in a high school 10 days after schools' reopening Probable aerosol transmission of SARS-CoV-2 in a poorly ventilated courtroom Transmission of Severe Acute Respiratory Syndrome Coronavirus 2 During Ling Flight Community Outbreak Investigation of SARS-CoV-2 Transmission Among Bus Riders in Eastern China Transmission of SARS-CoV-2 in Public Transportation Vehicles: A Case Study Transmission of SARS-CoV-2 on a Patient Transport Van COVID-19 Outbreak Associated with Air Conditioning in Restaurant Predicted Infection Risk for Aerosol Transmission of SARS-CoV-2 Investigation of a limited but explosive COVID-19 outbreak in a German secondary school + ±20% ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% ++ ±5% * Transmission occurred just in a volume of 47 m³ ** Only the Business Class is included where the majority of infections occurred Evaluation of the security of the boundary conditions ++ quite secure, + a bit insecure, 0 unknown/insecure, assumed level of deviation