key: cord-0304519-5oo7rr0u authors: Liu, Nan; Zheng, Liming; Xu, Jie; Wang, Jia; Hu, Cuixia; Lan, Jun; Zhang, Xing; Zhang, Jincan; Xu, Kui; Cheng, Hang; Yang, Zi; Gao, Xin; Wang, Xinquan; Peng, Hailin; Chen, Yanan; Wang, Hong-Wei title: Reduced graphene oxide membrane as supporting film for high-resolution cryo-EM date: 2021-04-15 journal: bioRxiv DOI: 10.1101/2021.04.15.439953 sha: 6aa4b7f38eb0819705fbc3b01177acd4bb032af5 doc_id: 304519 cord_uid: 5oo7rr0u Although single-particle cryogenic electron microscopy (cryo-EM) has been applied extensively for elucidating many crucial biological mechanisms at the molecular level, this technique still faces critical challenges, the major one of which is to prepare the high-quality cryo-EM specimen. Aiming to achieve a more reproducible and efficient cryo-EM specimen preparation, novel supporting films including graphene-based two-dimensional materials have been explored in recent years. Here we report a robust and simple method to fabricate EM grids coated with single- or few-layer reduced graphene oxide (RGO) membrane in large batch for high-resolution cryo-EM structural determination. The RGO membrane has decreased interlayer space and enhanced electrical conductivity in comparison to regular graphene oxide (GO) membrane. Moreover, we found that the RGO supporting film exhibited nice particle-absorption ability, thus avoiding the air-water interface problem. More importantly, we found that the RGO supporting film is particularly useful in cryo-EM reconstruction of sub-100 kDa biomolecules at near-atomic resolution, as exemplified by the study of RBD-ACE2 complex and other small protein molecules. We envision that the RGO membranes can be used as a robust graphene-based supporting film in cryo-EM specimen preparation. Single-particle cryo-EM, without the requirement of crystallization, has become a major method to solve structures of biological macromolecules at near-atomic resolution benefiting from its recent advances in both software and hardware (Cheng, 2015; Cheng, 2018; Li et al., 2013; Scheres, 2012; Wu et al., 2016) . The more recent breakthroughs even pushed the resolution to genuine atomic level (Nakane et al., 2020; Yip et al., 2020) . Furthermore, the method enables the analysis of heterogeneity to solve multiple conformers from one single cryo-EM dataset (Scheres, 2012) . While cryo-EM has become one of the most powerful methods in structural biology, a major bottleneck limiting the method's general application is the poor reproducibility and controllability to prepare cryo-EM specimen (Armstrong et al., 2020; Glaeser, 2016 Glaeser, , 2018 . The conventional and most popularly used cryo-EM specimen preparation procedure is to apply a droplet of solution containing target macromolecules onto an EM grid coated with holey carbon film, to blot the grid with filter paper and then to plunge-freeze the grid into liquid nitrogen temperature to form a very thin vitreous ice embedding the macromolecules (Dubochet et al., 1982; Grassucci et al., 2007) . During the blotting process to form thin liquid film, biomolecular particles with protein components tend to be absorbed onto the air-water interface, causing denaturation and preferred orientation (Glaeser, 2018; Noble et al., 2018) . The adsorption of molecules to the airwater interface was hypothesized to be the main reason of low yield in cryo-EM specimen preparation (D'Imprima et al., 2019; Noble et al., 2018) . To overcome this problem, thin films of various materials have been developed to support the biological macromolecules over holey grids. The most frequently used thin film is continuous amorphous carbon, which contributes to strong background noise, aggravate charging effect and beam-induced motion due to its poor electrical conductivity when imaged under electron microscopy (Russo and Passmore, 2014a, c; Zheng et al., 2020) . Graphene (Geim and Novoselov, 2007) , a two-dimensional nano-material with the superior properties of ultrahigh electrical/thermal conductivity (Balandin et al., 2008; Chen et al., 2008) , mechanical strength (Lee et al., 2008) and low background noise (Russo and Passmore, 2014a) , is considered as an ideal supporting film for cryo-EM specimen preparation. Graphene membrane as well as its derivatives, such as functionalized graphene (D'Imprima et al., 2019; Han et al., 2020; Liu et al., 2019; Naydenova et al., 2019; Russo and Passmore, 2014b) , have been reported to help successfully determining high-resolution reconstruction of multiple macromolecular structures by cryo-EM. The synthesis of single-crystalline graphene with large area, however, due to its high technical and resource demand (Lin et al., 2016) , is difficult to be established in regular laboratories focusing on biology. Moreover, the preparation of CVD-prepared or commercially available graphene onto EM grids normally involves many chemical reagents and is hard to avoid contaminations Regan et al., 2010; Zhang et al., 2017) . On the other hand, graphene oxide (GO) containing plenty of functional groups like carboxyl or epoxy (Pantelic et al., 2010) can be easily generated by oxidizing graphite, therefore has been explored as supporting film for cryo-EM specimen preparation (Benjamin et al., 2016; Palovcak et al., 2018; Pantelic et al., 2010; Wang et al., 2020; Wilson et al., 2009) . However, GO membrane is electrical insulative (Jung et al., 2008; Wang et al., 2018) , which may cause charging accumulation in the irradiated region (Egerton et al., 2004) . In addition, the space of interlayer in multiple-layer GO films is larger than that of multi-layer graphene because of the abundant functional groups and encapsulated solvent molecules in the GO films, introducing extra background noise (Moon et al., 2010; Qiu et al., 2015) . Herein, we develop a facile and robust strategy to use reduced graphene oxide (RGO) membrane as supporting substrate for cryo-EM specimen preparation. Compared with GO, RGO contained fewer functional groups with decreased interlayer space and better electric conductivity. Notably, the RGO membrane enabled nice absorption of target biomolecules and high-resolution cryo-EM reconstruction. Several sub-100 kDa biomolecules exhibited nice contrast on RGO membrane, and we successfully solved the structure of SARS-CoV2 RBD-ACE2 complex at 2.8 Å resolution. In our practice, the RGO membrane seemed particularly useful for cryo-EM analysis of relatively small protein molecules in low concentration. Graphene oxide (GO) could be produced by improved Hummers' method (Marcano et al., 2010) or commercially purchased, and dispersed in methanol/water solution. The GO layers were firstly coated onto holey-carbon EM grids following the previously reported method . The grids were then baked in an atmosphere of hydrogen/argon to reduce the GO membranes into RGO (Method, Schema 1 and Figure S1 ). RGO grids can be simply fabricated in large batch and we can normally prepare several hundred RGO grids at a time. We characterized the reduction efficiency of functional groups on GO by X-ray photoelectron spectroscopy (XPS) and found that the O1s peak intensity decreased after reduction treatment ( Figure 1A and Figure S2 ). The atomic ratio (O1s/C1s) of RGO was reduced to 0.16 from 0.38 of GO, consistent with the reported results by chemical graphitization (Moon et al., 2010) . We further analyzed the high-resolution spectra of Figure 1B and C). Accordingly, the peak area ratio of oxygen functional groups in RGO was down to 0.06, which was significantly decreased in comparison with that (~0.47) of GO. The spectrum analysis demonstrated that a large number of oxygen-containing functional groups on graphene oxide layers had been successfully eliminated by the reduction treatment. In order to measure the interlayer distance of GO and RGO membranes, we coated both samples on fresh mica plate and examined them by atomic force microscopy (AFM). The interlayer space can be measured by the height profile of two neighboring layers. The space of RGO was 0.3~0.4 nm ( Figure 1E ), consistent with previous reports (Lian et al., 2018; Moon et al., 2010) , about half of that of GO with over 0.7 nm ( Figure 1D ) (Buchsteiner et al., 2006; Lian et al., 2018; You et al., 2013) . The interlayer space reduction can be explained by two reasons. First, the branching functional groups covalently bound onto GO layers stretch the interlayer space, while the layers of RGO stack more tightly due to the lack of branching functional groups. Second, the GO membranes with active functional groups may attract small molecules like water, further expanding the interlayer space (Lian et al., 2018) . The interlayer space of RGO is similar to that of the CVD-prepared multilayer graphene membranes of ~0.35nm, further indicating a similar structure of RGO to graphene. We further tested the electrical conductivity of GO and RGO to see which one is more conductive as the supporting material in EM. We verified that the GO sheet was electrically insulative (Qiu et al., 2015; Wang et al., 2018) and its sheet-resistance exceeded the measuring range in our characterization. In contrast, the sheet-resistance of RGO was dramatically reduced (~10 5 Ω per square), and the lowest resistance can be 20,000 Ω per square ( Figure 1F ). The coverage of RGO membrane on EM grids prepared as described above was more than 90% and free of contamination ( Figure 2A , and Figure S3 -S4). The reduction procedures barely broke the graphene membrane and kept the layer number of GO as in the initial coating ( Figure S3 ). It was ordinary to find single-layer graphene with good crystallinity covering an entire hole, as indicated by the selected area electrondiffraction pattern ( Figure 2A , and Figure S4 ). We further evaluated the layer number of graphene across holes and found that more than half of the counted holes were covered by single-layer graphene and ~40% were covered by two-layer graphene ( Figure 2B ), which verified that the majority of the holes were covered by single-or few-layer graphene film, thus generating much less background noise than conventional amorphous carbon supporting film. We tested the hydrophilicity of GO and RGO coated grids, by measuring the water contact angle (WCA) after low-energy plasma treatments. As expected, RGO grids with fewer functional groups exhibited larger WCA compared to GO grids, indicating stronger hydrophobicity. However, their WCAs were rapidly decreased when treated with plasma cleaning ( Figure 2C ), suitable to be used for cryo-EM specimen preparation. We analyzed the beam-induced effect of RGO and GO. After electron irradiation with an accumulated dose of ~200 e -/Å 2 at room temperature, the RGO membrane had no visible beam-induced footprints ( Figure 2D ), probably due to its improved electrical conductivity. In contrast, there were obvious beam-induced image marks left on the GO membrane after being irradiated with the same dose, exhibiting as "white disks" in defocused ( Figure 2E ) and "black disks" in over-focused micrographs ( Figure 2F ). These radiation-induced disks may be caused by charging (Brink et al., 1998; Danev et al., 2014; Hettler et al., 2018) or mass loss effects (Choppin et al., 2013; Jiang and Spence, 2009 ). On the electric-insulating GO membranes, charge could be built up by the accumulated electrons, generating a phase contrast that can be observed in out-of-focus micrographs ( Figure 2E -F). On the other hand, small molecules and functional groups sandwiched among GO layers are dose-sensitive and susceptible to electron-beam bombardment (Moon et al., 2010; Zhang et al., 2009) , thereby causing decomposition at the exposed regions. We applied RGO grids to prepare cryo-specimens of 20S proteasome and ribosome, and collected datasets using the same parameters on a Tecnai Arctica microscope (200kV) with Falcon II camera ( Figure 3 ). The particles of both biomolecules were distributed as monodispersed and high-contrast particles on RGO supporting membranes ( Figure 3A and 3D). Radiation damage induced by the electron beam is one of the key concerns to be considered in cryo-EM imaging. High-resolution content, i.e., the chemical bonds in biomolecules, is hypothesized to be destroyed first by electron dose during EM imaging. B factor is proposed in cryo-EM field to model the dose and radiation damage on high-resolution information of biomolecules. Here, we ploted B factors of proteasome and ribosome supported by RGO grids with accumulated electron dose ( Figure 3B and 3E). The B factors of the first 1-5 e -/Å 2 dose were relatively higher than those of the following 5-10 e -/Å 2 , which was mainly resulted from the intial beam-induced motion (Scheres, 2016) . We calculated the decay rates of B factor after the first 10 e -/Å 2 of proteasome and ribosome, both of which were approximately 8 Å 2 /(e -/Å 2 ). Notably, the B-factor decay rates were close to the radiation damage measurements of protein 2D crystals . We also prepared cryo-EM specimens of 20S proteasome and ribosome using GO grids. Interestingly, after processing the three-dimensional reconstruction, the Euler angle distribution of particles on RGO was slightly different from that on GO. There were certain portion of 20S proteasome particles with top view (circle shape) on GO membrane ( Figure S5 ), which were totally absent on RGO ( Figure 3A ). Since 20S proteasome is highly symmetrical, these side-view projections on RGO were enough to reconstruct its structure. We finally obtained the 20S proteasome reconstruction at 4.4 Å resolution on RGO and 4.7 Å resolution on GO, using the same number of particle images. For ribosome sample of no symmetry, distribution of particle orientations was more balanced on RGO membrane ( Figure S6a and c) , thus enabling us to get a reconstruction of the ribosome with more reliable structural features than that determined by using particles on GO membranes ( Figure 3C , right and Figure S6 ). We further plotted the directional FSC ( Figure S7 ) and calculated the cryoEF value (Naydenova and Russo, 2017) , which was 0.28 on GO grid, while 0.42 on RGO grid. Both the directional FSC plots and cryoEF values indicated that ribosome particles on RGO adopted richer orientations. Such variation of particle-orientation performance was probably due to the distinct interacting favor of the biomolecular local surface with the functional groups on supporting membranes whose composition and distribution are different between GO and RGO surfaces. The overall resolution of ribosome reconstruction was reported as 6.1 Å on RGO, which was 8.0 Å on GO ( Figure S8 and S9) . Furthermore, we evaluated the protein particle's distribution in the vitreous ice on RGO-supported specimen using cryo-electron tomography (cryo-ET) technique and found that the majority of particles were absorbed onto RGO surface, thus avoiding damage by the air-water interface ( Figure 3G ). The ice thickness of the tomogram reconstruction was estimated to be ~20 nm, indicative of little extra background noise generated by the ambient ice. From the above analysis, we reasoned that the RGO grid should benefit more to the cryo-EM analysis of smaller macromolecules. We therefore further tested the application of RGO grids on cryo-EM imaging of small biomolecules, such as a 60-kDa protein glycosyltransferase ( Figure S10a ) and a 50-kDa protein Rv2466c ( Figure S10b ), both demonstrating particle images of monodisperse and good contrast. Notably, using the RGO grids, Bai et al reconstructed the cryo-EM structure of DEAH-box ATPase/helicase Prp2 (~100 kDa) at a better-than-3-Å resolution, revealing the role of Prp2 in RNA translocation and spliceosome remodeling (Bai et al., 2020) . COVID-19 virus was identified as a novel pathogenic coronavirus emerging to be an enormous threat to the global public health. Receptor binding domain (RBD) of its spike protein exhibited high binding affinity to the ACE2 receptor on human cells . We applied RGO grids to prepare the cryo-specimen of RBD-ACE2 complex (95 kDa) and can unambiguously recognize monodispersed particles with good density and contrast on RGO-film-covered area where the graphene diffraction spots were clearly revealed in the Fourier transform ( Figure S11a ). The contrast of protein particles absorbed on RGO film was further improved when utilizing volta phase plate in cryo-EM ( Figure 4A ). In contrast, in the area where RGO film was broken (i.e., without RGO membrane support), the RBD-ACE2 particles density was significantly decreased and many extra noisy spots of smaller size compared with target particles were observed in the background ( Figure 4B and Figure S13b ), probably composed of denatured proteins or dissociated components due to the air-water interface interaction ( Figure 3G ). From these particle images, we were able to obtain reconstruction of the RBD-ACE2 complex at 2.8 Å resolution and build the atomic model of RBD-ACE2 complex ( Figure 4C-F) . The interaction interface of ACE2 and RBD of spike protein was clearly recognized in the cryo-EM density ( Figure 4E ). Interestingly, we found that the cryo-EM structure was more compact than the previously reported structure of the same complex solved by X-ray crystallography ( Figure 4G -I) (Lan et al., 2020) . There are two possibilities that might lead to such difference. One possibility is that a distinct conformation is favored in the crystal packing of RBD-ACE2 complex during crystallization. While in cryo-EM reconstruction, particles are supposed to be in solution, thus adopting a different conformation. The other possibility is that the adsorption of RBD-ACE2 particles to RGO surface might trap the complex at a specific state. Taken together, the RGO grid was suitable for better protein preservation and cryo-EM analysis of some small biomolecules. Graphene membrane has long been explored as the supporting film in electron microscopy (Wilson et al., 2009) . The sp 2 carbon-atom crystalline lattice enables graphene ultrahigh electrical/thermal conductivity. The single-atomic thickness much smaller than the mean free path of electron presents negligible background noise. Yet its practical application is largely limited by the difficulty of reproducible high-quality graphene synthesis and free-of-contamination transfer onto EM grids. Here we described a robust method to fabricate single-or few-layer reduced graphene oxide membrane coated EM grids in large scale. We demonstrated that RGO contained decreased interlayer space and fewer functional groups, compared with GO. Importantly, we found that RGO can recover the electrical conductivity to a certain extent and the capability of reducing charging effects, thus improving the image stability. RGO was able to keep particles on its surface and more friendly than the airwater interface. We finally applied RGO grids for cryo-EM specimen preparation of sub-100 kDa protein samples to reconstruct the small molecules at near atomic resolution. What needs to be pointed out here is that adsorption of particles onto the surface of graphene supporting film often resulted in preferred orientation or other unfavorable consequences that still limited the resolution that could be achieved. Better reconstruction results might be obtained by using RGO with multiple bioactive functionalization. The graphene oxide solution was purchased from Sigma-Aldrich company (Lot #777676) or prepared by improved Hummer's method (Marcano et al., 2010) . Briefly, 9g KMnO4 and 1.5 g graphite flakes were added and mixed into 200 mL acid solvent (H2SO4/H3PO4 with a volume ratio of 9:1). The mixed solution was then stirred for 12 hours at 50 ℃. Afterwards, the solution was cooled down in ice bath and was added with 200 mL ice-cold water containing 3 mL H2O2. After 2-hour standing on ice, the mixture was centrifuged at 5000 g for 20 min, and the precipitate was carefully collected and washed, and finally resuspended in distilled water to make graphene oxide (GO) solution. Graphene oxide membrane was transferred onto Quantifoil gold EM grids by a similar procedure described by Palovcak et al. (Palovcak et al., 2018) . Briefly, the GO solution was first mixed into the dispersant (methanol/water with a volume ratio of 5:1) and sonicated for 10 min. The solution was next centrifuged at 4000 g for 10 min and the pellets were resuspended in the dispersant solution, followed by a 2-min sonication. Then the GO solution was centrifuged at 500 g for 1 min, and the supernatant was carefully collected for coating EM grids. When fabricating GO EM grids, we firstly submerge a steel mesh stand covered by a piece of filter paper into a water-filled container with outlets at its bottom (Supplementary Figure 1B) . The Quantifoil gold EM grids were mildly glow-discharged in advance and put onto the steel stand. GO solution was gently pipetted onto the water bath surface to form GO film and the water was slowly drained to lay the GO film onto the grid surface. Finally, the EM grids supported by the filter paper were carefully taken out from the container and air-dried at a 60 o C baker. The as-fabricated GO grids were placed in a quartz boat and put into a clean tube furnace at room temperature. A flow of 100 sccm H2 and 100 sccm Ar was introduced to drain the air out of the furnace. The GO grids were then heated to 300 o C at a rate of 2 o C/min, under the atmosphere of 100 sccm H2 and 100 sccm Ar. Subsequently, the grids were reduced at 300 o C for 1 hour under the same atmosphere. After reduction, the grids were naturally cooled down to room temperature and ready for use. The morphologies of the GO and RGO membranes were characterized using AFM (Bruker dimension icon, scansyst mode, scansyst air tip). The composition characterizations of GO and RGO membranes were conducted with XPS (Kratos Analytical AXIS-Ultra with monochromatic Al Kα X-ray). The four-probe resistance measuring meter (CDE ResMap 178) was used to measure the sheet resistances of GO and RGO membranes on mica substrates. The graphene layer number was determined by the diffraction pattern under TEM. The first-order diffraction pattern of single-layer graphene contained six spots, the density of which were similar with that of the secondorder diffraction spots. The water contact angle of RGO and GO grids after plasma treatment was measured by the optical contact angle measuring device (Dataphysics company). To measure the sheet resistance, four-point probes were equally spaced and arranged in a line on the target material. By measuring the current (I) through the outside two probes and the voltage (V) across the inside two probes, the average sheet resistance (Rs) of the conducting film can be acquired. When the thickness of the conducting film is much less than the spacing of probes, and the width of film is apparently larger than the spacing distance, the average sheet resistance can be given by Rs=4.53V/I. Thermoplasma acidophilum 20S proteasome was recombinantly expressed in Escherichia coli cells and purified as described previously (Li et al., 2013) . Yeast ribosomes were purified from yeast cells following previously published protocols (Ma et al., 2017) . RBD-ACE2 complex was prepared according to methods utilized in (Lan et al., 2020) . ~3μL solution containing purified biomolecules was pipetted onto freshly glow discharged RGO grids, and then transferred into an FEI Vitrobot. For glow discharging, we used low-energy plasma to treat the RGO grids for 15s in a Harrick PDC-32G plasma cleaner. The humidity of Vitrobot chamber was kept as 100% and the temperature as 8℃. The grids were then blotted 2s with -2 force, immediately followed by plunge-freezing into liquid ethane cooled at liquid nitrogen temperature. After that, the grids were quickly transferred into liquid nitrogen for storage. The single-particle cryo-EM datasets of 20S proteasome and ribosome were collected on an FEI Tecnai Arctica (200 kV), equipped with an Falcon II detector. The RBD-ACE2 dataset was collected on an FEI Titan Krios (300 kV), equipped with a Gatan K3 summit detector and Volta phase plate, using AutoEMation software (Fan et al., 2017; Lei and Frank, 2005) . All micrographs were dose-dependently fractionated into 32 frames, with an accumulated dose of 50 e -/Å 2 . The individual frames were firstly motion-corrected by MotionCor2 algorithm and the resulted micrographs were imported into Relion3.0 (Zivanov et al., 2018) for further processing. CTF values were calculated by CTFFIND4 package (Rohou and Grigorieff, 2015) . Biomolecular particles were autopicked and iteratively 2D classified in Relion3.0. Particles grouped in good classes exhibiting fine structural details were selected for further 3D classification and refinement. We used Fourier Shell Correction (FSC) 0.143 cutoff criteria to estimate the resolution in the final postprocessing step in Relion3.0. Finally, we used 10,000 and 8,453 particles for the reconstructions of 20S proteasome and ribosome. The resolution of 20S proteasome and ribosome on RGO grids was 4.5 Å and 6.1 Å, respectively. For RBD-ACE2 complex, we finally used 110,122 particles and got a reconstruction at 2.8 Å resolution. All figures related to cryo-EM structures were created in UCSF Chimera (Pettersen et al., 2004) . The directional FSC curves were generated in remote 3DFSC processing server (https://3dfsc.salk.edu) . Cryo-ET micrographs series were obtained on an FEI Titan Krios microscope (300 kV), equipped with a Gatan K2 camera. We used SerialEM (Mastronarde, 2005) to collect tilt series, and the specimen was tilted from +51 ̊ to -51 ̊ with an acquired step of 3 . The total dose was 100 e -/Å 2 with a dose rate of ~3 e -/Å 2 /s, and the calibrated pixel size was 1.77 Å. The micrographs series was imported into IMOD (Kremer et al., 1996) for reconstruction, where the position of protein particles was manually identified as previously (Liu et al., 2019) . Comparison between the cryo-EM structure solved in this work (colored in pink) with the reported X-ray crystal structure (PDB: 6M0J, in green). H. RMSD (Å) between the cryo-EM structure and the X-ray crystal structure. I. 3D vector map between the cryo-EM structure and the X-ray crystal structure, using RBD as the alignment reference. The vector lengths indicated the displacement scale across these two structures. Microscale Fluid Behavior during Cryo-EM Sample Blotting Mechanism of spliceosome remodeling by the ATPase/helicase Prp2 and its coactivator Spp2 Superior thermal conductivity of single-layer graphene Selective Capture of Histidine-tagged Proteins from Evaluation of charging on macromolecules in electron cryomicroscopy Water dynamics in graphite oxide investigated with neutron scattering Charged-impurity scattering in graphene Single-Particle Cryo-EM at Crystallographic Resolution Single-particle cryo-EM-How did it get here and where will it go Absorption of Nuclear Radiation Protein denaturation at the air-water interface and how to prevent it Volta potential phase plate for in-focus phase contrast transmission electron microscopy Electron-Microscopy of Frozen Water and Aqueous-Solutions Radiation damage in the TEM and SEM Near-Atomic Resolution Structure Determination in Over-Focus with Volta Phase Plate by Cs-Corrected Cryo-EM The rise of graphene Specimen Behavior in the Electron Beam Proteins, Interfaces, and Cryo-Em Grids Preparation of macromolecular complexes for cryo-electron microscopy High-yield monolayer graphene grids for near-atomic resolution cryoelectron microscopy Charging of carbon thin films in scanning and phase-plate transmission electron microscopy Radiation damage in zircon by high-energy electron beams Tunable Electrical Conductivity of Individual Graphene Oxide Sheets Reduced at "Low" Temperatures Computer visualization of three-dimensional image data using IMOD Structure of the SARS-CoV-2 spike receptor-binding domain bound to the ACE2 receptor Measurement of the elastic properties and intrinsic strength of monolayer graphene Automated acquisition of cryo-electron micrographs for single particle reconstruction on an FEI Tecnai electron microscope Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM Extraordinary water adsorption characteristics of graphene oxide Rapid Growth of Large Single-Crystalline Graphene via Second Passivation and Multistage Carbon Supply Bioactive Functionalized Monolayer Graphene for High-Resolution Cryo-Electron Microscopy Structural snapshot of cytoplasmic pre-60S ribosomal particles bound by Nmd3, Lsg1, Tif6 and Reh1 Improved synthesis of graphene oxide Automated electron microscope tomography using robust prediction of specimen movements Reduced graphene oxide by chemical graphitization Multifunctional graphene supports for electron cryomicroscopy Measuring the effects of particle orientation to improve the efficiency of electron cryomicroscopy Reducing effects of particle adsorption to the air-water interface in cryo-EM A simple and robust procedure for preparing graphene-oxide cryo-EM grids Graphene oxide: a substrate for optimizing preparations of frozen-hydrated samples The energy dependence of contrast and damage in electron cryomicroscopy of biological molecules UCSF chimera -A visualization system for exploratory research and analysis Hydrogen reduced graphene oxide/metal grid hybrid film: towards high performance transparent conductive electrode for flexible electrochromic devices A direct transfer of layer-area graphene CTFFIND4: Fast and accurate defocus estimation from electron micrographs Controlling protein adsorption on graphene for cryo-EM using low-energy hydrogen plasmas Controlling protein adsorption on graphene for cryo-EM using low-energy hydrogen plasmas Ultrastable gold substrates for electron cryomicroscopy RELION: implementation of a Bayesian approach to cryo-EM structure determination Processing of Structurally Heterogeneous Cryo-EM Data in RELION Addressing preferred specimen orientation in single-particle cryo-EM through tilting Amino and PEG-amino graphene oxide grids enrich and protect samples for high-resolution single particle cryo-electron microscopy Reduced graphene oxide film with record-high conductivity and mobility Graphene Oxide: Structural Analysis and Application as a Highly Transparent Support for Electron Microscopy Single-particle cryo-EM data acquisition by using direct electron detection camera Enormous lattice expansion of hummers graphite oxide in alcohols at low temperatures Clean Transfer of Large Graphene Single Crystals for High-Intactness Suspended Membranes and Liquid Cells Synthesis and characterization of a graphene-C-60 hybrid material Robust ultraclean atomically thin membranes for atomicresolution electron microscopy MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy A pneumonia outbreak associated with a new coronavirus of probable bat origin New tools for automated high-resolution cryo-EM structure determination in RELION-3