key: cord-0298811-cg1loh90 authors: Walshe, N.; Fennelly, M.; Hellebust, S.; Wenger, J.; Sodeau, J.; Prentice, M.; Grice, C.; Jordan, V.; Comerford, J.; Downey, V.; Perrotta, C.; Mulcahy, G.; Sammin, D. title: Assessment of Environmental and Occupational Risk Factors for the Mitigation and Containment of a COVID-19 Outbreak in a Meat Processing Plant date: 2021-09-21 journal: nan DOI: 10.1101/2021.09.17.21262959 sha: e750d200965238d0fa1ca77dedc25f680972a9f1 doc_id: 298811 cord_uid: cg1loh90 Throughout the COVID-19 pandemic, meat processing plants have been vulnerable to outbreaks of SARS-CoV-2 infection. Transmission of the virus is difficult to control in these settings because of a combination of factors including environmental conditions and the specific nature of the work. This paper describes a retrospective outbreak investigation in a meat processing plant, a description of the measures taken to prevent or contain further outbreaks, and insights on how those with specific knowledge of the working environment of these plants can collaborate with public health authorities to ensure optimal outbreak control. The plant experienced 111 confirmed positive asymptomatic cases in total with an estimated attack rate of 38% during a five-week period. Four weeks after the first case, mass screening of all workers was conducted by the public health authorities. Thirty-two workers tested positive, of which 16 (50%) worked in one particular area of the plant, the boning hall (n=60). The research team prepared and carried out semi-structured interviews with the plant personnel who were charged with COVID control within the plant. They carried out assessments of operational risk factors and also undertook air quality monitoring in the boning hall and abattoir. The air quality measurements in the boning hall showed a gradual build-up of carbon dioxide and aerosol particles over the course of a work shift, confirming that this poorly ventilated area of the plant had an environment that was highly favourable for aerosol transmission of SARS-CoV-2. Assessment of operational conditions incorporated visual surveys of the plant during the working day. Prior to and during the first two weeks of the outbreak, multiple measures were introduced into the plant by management, including physical distancing, provision of educational material to workers, visitor restrictions, and environmental monitoring. After the implementation of these measures and their progressive refinement by plant management, the factory has not had any further linked cases (clusters) or outbreaks to date. The tailored approach to risk mitigation adopted in this meat processing plant shows that generic risk mitigation measures, as recommended by public health authorities, can be successfully adapted and optimized by designated plant emergency response teams. Throughout the COVID-19 pandemic, meat processing plants have been vulnerable to 18 outbreaks of SARS-CoV-2 infection. Transmission of the virus is difficult to control in these 19 settings because of a combination of factors including environmental conditions and the 20 specific nature of the work. This paper describes a retrospective outbreak investigation in a 21 meat processing plant, a description of the measures taken to prevent or contain further 22 outbreaks, and insights on how those with specific knowledge of the working environment 23 of these plants can collaborate with public health authorities to ensure optimal outbreak 24 control. The plant experienced 111 confirmed positive asymptomatic cases in total with an 25 estimated attack rate of 38% during a five-week period. Four weeks after the first case, mass 26 screening of all workers was conducted by the public health authorities. Thirty-two workers 27 tested positive, of which 16 (50%) worked in one particular area of the plant, the boning hall 28 (n=60). The research team prepared and carried out semi-structured interviews with the plant 29 personnel who were charged with COVID control within the plant. They carried out 30 assessments of operational risk factors and also undertook air quality monitoring in the 31 boning hall and abattoir. The air quality measurements in the boning hall showed a gradual 32 build-up of carbon dioxide and aerosol particles over the course of a work shift, confirming 33 that this poorly ventilated area of the plant had an environment that was highly favourable 34 for aerosol transmission of SARS-CoV-2. Assessment of operational conditions 35 incorporated visual surveys of the plant during the working day. Prior to and during the first 36 two weeks of the outbreak, multiple measures were introduced into the plant by 37 management, including physical distancing, provision of educational material to workers, 38 3 throughout the pandemic, operating within guidelines provided by public health authorities. 84 The agri-food industry accounts for ~8% of Ireland's GDP and ~160,000 jobs 2 . The meat-85 processing industry is not only an important component of the agri-food sector, it also forms 86 an important part of the national and international food supply. Therefore, not only from a 87 public health point of view but also from an economic perspective, it is crucial to the 88 industry, the workers, and the wider national community that investigation into potential risk 89 factors for SARS-CoV-2 transmission, in Irish meat processing plants is conducted The key considerations arising from this initial review of the literature informed both the 124 study design and the composition of the investigative team. These included the increasing 125 recognition of superspreading events giving rise to large numbers of cases of COVID-19 in 126 various congregate settings and the likely importance of aerosol transmission in these 127 events, as distinct from either droplet or contact transmission (1, 2, 7-13). The working 128 assumption was that a superspreading event was likely to have occurred within meat plants 129 in which large numbers of PCR positive workers were identified. This led to the hypothesis 130 2 https://www.bordbia.ie/industry/irish-sector-profiles/ . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint that conditions within meat plants may favour aerosol transmission of the virus and clarified 131 the objective of the pilot studyto observe and measure operational and environmental 132 factors that would support or refute this hypothesis by engaging in a retrospective 133 investigation of a COVID-19 outbreak in a meat processing plant. The study design ( Figure 134 1) included the collection of epidemiological, operational, and environmental data. 135 136 The following criteria were used to select the plant: 1) That an outbreak of COVID-19 had 137 occurred in the plant in early-mid 2020, 2) that mass PCR testing of the workforce had been 138 undertaken as part of the outbreak investigation, 3) that a large proportion of the workforce 139 had tested positive for the virus, and 4) that the plant comprised all aspects of primary 140 processing of red meat at one site, including slaughter, The areas for air quality assessment were pre-selected based on documented evidence on the 176 proportion of the overall number of PCR-positive cases which had occurred in each area 177 during the outbreaknotably a meat cutting room or "boning hall" with a relatively high 178 proportion of the cases and an abattoir with a relatively low proportion of the cases. Indoor 179 air quality measurements were conducted in these two areas of the plant over several days in 180 . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Both instruments were enclosed in a cabinet with air sample intake at a height of 1.5 m 187 above ground level and deployed in the boning hall for three days and in the abattoir for two 188 days. The measured CO2 concentrations were averaged over 5 minute intervals, while the 189 fluorescent and total particle counts were summed over the same 5 minute interval. 190 191 In a follow-up study, the performance of a newly-installed air filtration device ( 3.1 Characteristics of the Outbreak 210 The MPP at the time of the outbreak had a total of 290 workers distributed across 20 211 different areas and departments. A worker in the boning hall was absent from work in early 212 2020. This person developed symptoms while absent from work and also tested positive six 213 days later. They indicated that their spouse had also subsequently developed symptoms and 214 tested positive for COVID-19. This was the first case in which it was suspected that 215 infection had been acquired within the plant. It occurred approximately one month after the 216 first case documented in Ireland, and two weeks after the first public health restrictive 217 measures were introduced. By the end of March 2020, there were 2990 officially diagnosed 218 cases of COVID-19 in Ireland, the number of admissions to hospital was 834 (27.9%) and 219 the epidemic trajectory was increasing. The second symptomatic case was also a worker in 220 the boning hall who presented with symptoms three days after the index case had been 221 reported as symptomatic. An outbreak (defined by the HSE as two or more cases occurring 222 within 14 days) was declared on this day. The third symptomatic case, also a worker in the 223 boning hall, presented the following day. The fourth symptomatic case was from outside the 224 boning hall, and had frequented a common area available to all MPP employees. Subsequent 225 cases occurred in other areas of the plant, as outlined in Table 1 . A summary timeline of 226 detection of PCR-positive cases is shown in Figure 2 . 227 228 . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The average CO2 concentrations and particle number concentrations measured during the 309 daytime working shifts (between 07:00 and 15:00) in the boning hall over a three-day period 310 and the abattoir over a two-day period are shown in Figure 3 . The CO2 concentration in the 311 boning hall showed a gradual increase throughout each working shift shift but dropped 312 sharply on two occasions, corresponding to break times when the workers left the hall. 313 However, when the workers returned, the amount of CO2 quickly increased again. The 314 average count of fluorescent and total particles of less than 2.5 µm diameter (PM2.5) also 315 gradually increased over the course of each working shift in the boning hall. 316 317 In contrast, the CO2 concentration in the abattoir showed a marked decrease during the 318 working shift and at one point reached levels close to typical outdoor values (ca. 415 ppm). 319 The total particle concentration in the abattoir fluctuated greatly during the working day. 320 However, the number of fluorescent particles was low and showed no significant change 321 over time. The average air temperatures were 10 ℃ in the boning hall and 18 ℃ in the 322 abattoir. The relative humidity was higher on average in the abattoir (71%) than in the 323 boning hall (66%). 324 325 The air handling regimes differed between both areas of the plant -warm, humid air was 326 continuously extracted from the abattoir whereas chilled air was being continuously 327 . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint and air exchange was limited to that which occurred through openings into adjacent areas of 331 the plant. Based on the decay of CO2 concentration during the two break periods (Figure 3) , 332 it is estimated that the boning hall undergoes 0.4-0.5 ACH. This is indicative of poor 333 ventilation and explains the gradual rise in both particle counts and CO2 over each working 334 shift. Furthermore, the accumulation of fluorescent particles in this area suggests that 335 bioaerosols are present in the air and remain airborne for the duration of the working shift. 336 337 The impact of installing air filtration units on average particle counts measured by the 339 WIBS-4a during the different operational modes of the filtration unit is provided in Table 2 . 340 The results are based on measurements made during working shifts where the filtration unit 341 was not operational (18 hours), operating at full capacity (5 hours) and 50% capacity (45 342 hours). The filtration unit reduced the total number of particles < 2.5 µm by 75% and 86% 343 when operating at half and full capacity respectively. Similar results were obtained for the 344 fluorescent fraction of particles, as well as particles > 2.5 µm. 345 346 In the boning hall, workers were typically in stationary positions and operated less than 1 m 348 from each other but were separated by panels and were provided with surgical masks and 349 visors. Social interaction was limited due to the physical barriers. Human occupancy was 350 much higher in the boning hall than in the abattoirwith three times less floor area per 351 person ( is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint of SARS-CoV-2 over distances as much as 8 metres in a MPP, and also highlighted the 405 increased risk in meat cutting rooms which, for food safety reasons, have to be maintained at 406 low temperature, and this is typically achieved by recirculation of chilled air. 407 408 The operational conditions in the boning hall of the MPP investigated during this study is 409 very similar to that reported by Gunther et al (12) and this is the area of the plant where the 410 largest number of PCR-positive cases were detected among workers. Two risk factors 411 combine within boning halls to provide an environment that is highly favourable for aerosol 412 transmission of SARS-CoV-2 as well as other airborne infectionsthese being high 413 occupancy and poor ventilation. Boning halls tend to be more densely populated than other 414 work areasthat in the present study had three to four times the occupancy of the abattoir in 415 the same plant. Meanwhile air quality results in this study, showing a gradual increase in 416 CO2 levels and in suspended bio-aerosols over the course of a working shift within the 417 boning hall (but not in the abattoir) confirm that this area of the plant is poorly ventilated. 418 Our results indicate that CO2 concentration is closely corelated with occupancy levels. 419 Bioaerosols could have originated from exhaled respiratory particles emitted by the workers 420 (which could contain the SARS-CoV-2 virus) or from tiny particles of meat and bone that 421 became airborne. 422 423 The ventilation regime currently implemented in boning halls is deliberate. EU food hygiene 424 legislation requires that meat cutting rooms are maintained at a temperature of less than 12 425 °C (to ensure that red meat is kept at below 7 °C). Up until now, the international industry 426 . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 21, 2021. ; https://doi.org/10.1101/2021.09.17.21262959 doi: medRxiv preprint norm to achieve these working conditions in meat cutting rooms has been to continuously 427 recirculate chilled air with little or no fresh air intake or filtration. 3 However, this legislative 428 requirement introduced in the wake of the BSE crisis, predates some fundamental changes 429 in the efficiency of meat processing. Typically, meat cutting is now a much more 430 streamlined, assembly-line process with greater throughput and shorter chill-to-chill transit 431 times than heretofore. EU legislation already allows for alternatives (to a working 432 temperature of less than 12 degrees) to achieve the same effect (of keeping red meat at less 433 than 7 degrees). This legislative proviso coupled with current more efficient processes 434 provide scope to explore if meat cutting could be performed in rooms operated at a higher 435 ambient temperature without compromising on food safety. If such an alternative were 436 validated, there would be less of a requirement to recirculate air and more fresh air could be 437 introduced to meat cutting rooms without significantly increasing the energy costs or carbon 438 footprint of meat processing. Work to investigate if modifying this requirement, while still 439 providing for food safety considerations, is underway. and operation of a large HEPA filtration unit within the boning hall investigated in this study 458 was shown to reduce the build-up of airborne particles over the course of a working shift. 459 Significant reductions in particle counts were achieved even when the filtration unit was 460 only operating at half its functional capacity. While a further reduction could be achieved if 461 the unit was operated at full capacity, this was associated with a "wind chill" effect and was 462 excessively noisy, negatively impacting on worker comfort and therefore unlikely to be 463 acceptable on a long-term basis. Further work to assess the importance of such measures 464 will be important in mitigating ongoing risk. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint Abattoir and Boning hall Correlation of enviornmental and operational factors with risk and effects of mitgation . CC-BY-NC-ND 4.0 International license It is made available under a perpetuity. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 21, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 21, 2021. is the author/funder, who has granted medRxiv a license to display the preprint in (which was not certified by peer review) preprint The copyright holder for this this version posted September 21, 2021. ; https://doi.org/10.1101/2021.09.17.21262959 doi: medRxiv preprint Livestock plants and COVID-19 533 transmission Meat plants-a new front line in the 535 covid-19 pandemic COVID-19 Among Workers in Meat and 537 Poultry Processing Facilities -19 States COVID-19 Pandemic: Prevention and Protection Measures 541 to Be Adopted at the Workplace Superspreading events in the transmission dynamics of SARS-CoV-2: Opportunities for 545 interventions and control The Presentation and Diagnosis of the First Known Community-Transmitted Case 549 of SARS-CoV-2 in the Republic of Ireland Effects of temperature and humidity on the daily new cases 552 and new deaths of COVID-19 in 166 countries Aerodynamic analysis of SARS-CoV-2 in two Wuhan 555 hospitals. 556 Stability of SARS-CoV-2 in different environmental 558 conditions Community Outbreak Investigation of SARS-CoV Johnson-Lussenburg CM Survival 563 Characteristics of Airborne Human Coronavirus 229E SARS-CoV-2 567 outbreak investigation in a German meat processing plant Investigation of 571 superspreading COVID-19 outbreak events in meat and poultry processing plants in 572 Germany: A cross-sectional study Review: The 575 Use of Real-Time Fluorescence Instrumentation to Monitor Ambient Primary Biological 576 Aerosol Particles (PBAP). Atmosphere Ten scientific 578 reasons in support of airborne transmission of SARS-CoV-2. Lancet Control of respirable particles in indoor air with portable air cleaners Initial funding for the Pilot Study was provided by DAFM. The work is further supported 599 by COVID Rapid Response grant 20/COV/8436 from Science Foundation Ireland We are grateful to Meat Industry Ireland and their member companies for supporting this 604 work and for ongoing studies under the Science Foundation Ireland grant listed above. We 605 also thank colleagues from the Health and Safety Authority, and in particular Jason Murray