key: cord-0298462-0lxmi4jk authors: Sharma, A.; Nenert, R.; Mueller, C.; Maudsley, A.; Younger, J.; Szaflarski, J. P. title: Repeatability and reproducibility of in-vivo brain temperature measurements date: 2020-10-31 journal: nan DOI: 10.1101/2020.10.27.20220715 sha: e8a9f220b485fa25915ab95c0413d7186928a34c doc_id: 298462 cord_uid: 0lxmi4jk Background. Magnetic resonance spectroscopic imaging (MRSI) is a neuroimaging technique that can be used to noninvasively map brain temperature (i.e., thermometry) over a large brain volume. To date, intra-subject reproducibility of MRSI-based brain temperature (MRSI-t) has not been investigated. The objective of this repeated measures MRSI-t study was to establish intra-subject reproducibility and repeatability of brain temperature, as well as typical brain temperature range. Methods. Healthy participants aged 23-46 years (N=18; 7 females) were scanned at two time points, ~12-weeks apart. Volumetric MRSI data were processed by reconstructing metabolite and water images using parametric spectral analysis. Brain temperature was derived using the frequency difference between water and creatine (TCRE) for 47 regions of interest (ROIs) delineated by the modified Automated Anatomical Labeling (AAL) atlas. Reproducibility was measured using the coefficient of variation for repeated measures (COVrep), and repeatability was determined using the standard error of measurement (SEM). For each region, the upper and lower bounds of Minimal Detectable Change (MDC) were established to characterize the typical range of TCRE values. Results. The mean global brain temperature over all subjects was 37.2{degrees}C, with spatial variations across ROIs. There was a significant main effect for time (F(1, 1591)=37.0, p < 0.0001) and for brain region (F(46, 1591)=2.66, p<0.0001). The time*brain region interaction was not significant (F(46, 1591)=0.80, p=0.83)). Participants' TCRE was stable for each ROI across both time points, with ROIs' COVrep ranging from 0.81 - 3.08% (mean COVrep = 1.92%); 30 ROIs had a COVrep < 2.0%. Conclusions. Brain temperature demonstrated subtle regional variations that were highly consistent between both time points, indicating high reproducibility and repeatability of MRSI-t. MRSI-t may be a promising diagnostic, prognostic, and therapeutic tool for non-invasively monitoring pathological brain temperature changes when other modalities are unrevealing. However, further studies of healthy participants with larger sample size(s) and numerous repeated acquisitions are imperative for establishing a reference range of typical brain TCRE, as well as the threshold above which TCRE is likely pathological. Neuroinflammation is increasingly implicated in the initiation and maintenance of a number 63 of neurodegenerative diseases, including multiple sclerosis, Alzheimer's Disease, and epilepsy 64 (Lucas et Szaflarski, 2020). Therefore, there is a dire need to identify a sensitive and specific in vivo 70 biomarker of neuroinflammatory pathophysiology. Currently available approaches are invasive 71 and/or costly (e.g., lumbar puncture, positron emission tomography [PET] ). Further, PET relies on 72 the use of radioisotopes that may localize key neuroinflammatory cells, but variable quantitative 73 accuracy, limited bioavailability, and unclear specificity of ligand-target binding are critical gaps that 74 limit its clinical utility (Hamelin et overwhelm the brain's already limited cooling mechanisms and drive brain temperature by 1-84 2°C higher than core body temperature (Rossi et al., 2001). As neuroinflammatory phenomena such 85 as leukocyte extravasation and accumulation, blood brain barrier permeability, and even cerebral 86 edema increase, so does brain temperature (Dietrich et al., 1996 (Dietrich et al., , 1998 Chatzipanteli et al., 2000; 87 Sharma and Hoopes, 2003). 88 Of the ways we can measure brain temperature, magnetic resonance spectroscopic imaging 89 (MRSI) is the most non-invasive and economical. Brain temperature can be derived from MRSI data 90 by calculating the frequency difference between the temperature-sensitive water peak and one or 91 more metabolite peaks that are temperature-insensitive (Maudsley et al., 2017) . MRSI-based brain majority of previous studies have performed MRSI-t measurements only at a single brain location or 98 limited spatial region, but it has recently been demonstrated that the measurement can be obtained 99 using a volumetric echo-planar spectroscopic imaging (EPSI) acquisition to create temperature maps 100 over a large fraction of the brain volume (Maudsley et al., 2006 (Maudsley et al., , 2017 . Limited data are available on 101 the reproducibility and reliability of MRSI-t using volumetric EPSI. Previous work has established 102 intra-subject reproducibility of serial EPSI acquisitions in a limited sample (N=2) at 5 one-week 103 intervals, as well as that of successive EPSI acquisitions (2 per session) in a larger sample (N=32) 104 (Maudsley et al., 2010; Veenith et al., 2014) . However, the reproducibility and repeatability of 105 MRSI-t using volumetric EPSI has only been established in a small sample (N=10), with 3 106 acquisitions separated by one-week intervals (Zhang et al., 2020). Thus, the available data do not 107 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint mirror a real-life clinical situation in which participants are typically exposed to a 108 treatment/intervention for 12-16 weeks before a second measurement is collected. 109 To date, no study has investigated whether intra-subject reproducibility is maintained in a 110 larger sample of healthy control participants with a longer duration between scans. Additionally, all 111 previous studies have only reported the coefficient of variation (COV) and intraclass correlation 112 coefficients as measures of reproducibility and repeatability; these data are useful, but the exact 113 boundary at which a given region's brain temperature is normal versus above-normal (i.e., areas of 114 focal neuroinflammation or other pathophysiological phenomena) remains uncertain (Maudsley et al., 115 2010; Zhang et al., 2020). Before MRSI-t can be used as a clinical tool for in vivo assessment of 116 neuroinflammation, we must determine whether MRSI-based brain temperature estimates are reliable 117 and reproducible over typical study periods. In addition to establishing bounds of normal global and 118 region-level brain temperature, it is critical that we determine the bounds at which brain temperature 119 is above-normal in each region. The objective of this study was to establish intra-subject 120 reproducibility and repeatability of brain temperature derivations in healthy participants scanned 121 twice, approximately 12 weeks apart. In addition to establishing typical mean brain temperature 122 across regions, we aimed to define the bounds of typical vs. atypical (i.e., possibly abnormal) brain Prior to imaging, tympanic temperature measurements were collected using a Braun Pro 4000 145 ThermoScan aural thermometer. 146 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint participant's mean CBF maps were then 1) registered to high-resolution structural space with affine 193 registration, followed by 2) non-linear registration to MNI space. i 194 hemispheric (right vs left) differences in region-level T CRE . Independent samples t-tests contrasting 218 sex differences in global and region-level T CRE were planned but not performed due to unequal sex 219 distribution in the final dataset. Data quality was evaluated on the basis of 1) number of accepted 220 voxels (%) following processing and 2) spectral linewidth. 221 Paired samples t-tests of participants' mean CBF maps contrasted cerebral perfusion between 222 the two time points. This served as a measure of whether brain temperature differences -if present -223 could be attributed to perfusion differences. 224 225 3 RESULTS 226 Twenty-one participants were recruited; 18 completed all study procedures and were included 228 in the analyses (N=7 females). The mean age was 30.39 ±7.47 years (range 23-46 years). 229 Descriptive statistics for study measures of temperature, blood flow, and inflammatory metabolite 230 ratios were tabulated for both time points; global within-subject differences from time1 to time2 were 231 computed with repeated measures t-tests ( was not clinically significant and scores remained in the normal range (0-7) for both time points 234 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. provided in Figure 1 . 238 The COVrep, our measure of reproducibility, ranged from 0.81 -3.08% (mean 1.92%) across 240 47 ROIs, with 30 ROIs having a COVrep < 2.0%. SEM ranged from 0.365 -2.713 (mean 1.295 ± 241 0.647) ( Table 2 ). The highest COVrep (3.08%) was in the R Fusiform Gyrus. Mean brain 242 temperature was the lowest in the R and L putamen, R and L pallidum, R and L hippocampus, L and 243 R anterior cingulum, R and L thalamus, and R insula ( Table 2 ). Mean brain temperature was highest 244 in the R occipital lobe, L and R precuneus, R and L frontal lobes, and R and L cuneus. 245 Based on the MDC, the T CRE at which we consider brain temperature as atypical varies across 246 brain regions ( (Table 252 2, Figure 2 ). In addition to assessing these ROI-based measures, brain temperature maps visualized 253 brain temperature changes within participants from time1 to time2 (Figure 3) . 254 A linear mixed effects model investigated the variation of T CRE across 47 brain regions over 2 256 time points. Fixed effects included time, brain region, and the interaction of time*brain region, with 257 participants considered random effects. In the case of a statistically significant interaction, we 258 planned follow-up tests to assess pairwise differences using simple effects analysis. For major metabolites (tCre, tCho, NAA, and MI), COVrep (%) values are provided in Table 274 4. In contrast to T CRE , metabolite concentrations varied substantially across time. For tCho, mean 275 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. NAA across regions at time1 is included in Figure 4 . 280 Spearman correlations were run to test the relationship between T CRE and the ratios MI/tCRE, 281 NAA/tCRE, and Glx/tCRE ( Glx/tCRE and MI/tCRE. However, none of the metabolite ratios were significant predictors of T CRE . 288 There were no significant differences in brain temperature when comparing left and right ROIs at 289 p<0.05, corrected for FDR. Due to unequal sex distribution of our participants in the final dataset, we 290 did not perform independent samples t-tests to evaluate sex differences in global and regional T CRE . 291 Our data were of moderate to high quality as indicated by the spectral resolution and total 293 percentage of voxels included in our final analysis. An average of 75.18 % of voxels within the brain 294 met quality criteria across both timepoints (76.47 ± 10.68% of voxels at T 1 , 73.89 ± 12.39% of 295 voxels at T 2 ), with a range of 48.13% to 89.53%. As indicated by the mean linewidth of 7.31 Hz 296 (range, 6.39 -8.69), our data also had high spectral resolution. 297 We performed post-hoc correlation analysis of SEM, COVrep, mean T CRE , and ROI size to 298 determine if there was an association between reproducibility, repeatability, T CRE , and region size. ROI 299 size was calculated by multiplying the mean # of voxels in each region (pre-processing) by the mean % 300 accepted voxels after processing. To adjust for varying scale, SEM, COVrep, mean T CRE , and ROI size 301 were z-transformed. Reproducibility and repeatability (COVrep*SEM) had a strong positive correlation 302 (r=0.805, p<0.001) ( . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. question was whether timepoint has an impact on the mean brain temperature within a given ROI. 319 Mixed effects analysis confirmed that brain temperature does change within ROIs as a function of 320 time, as indicated by the lack of a significant interaction (time*brain region, F(46, 1591)=0.80, 321 p=0.83)). Interestingly, the highest T CRE was found in 1) posterior regions affected by anterior-posterior 322 gradient effects (L and R occipital lobe, L and R cuneus, L and R precuneus), and 2) large peripheral 323 cortical regions (L and R frontal lobes, R parietal, L and R occipital would benefit from acquiring data both with and without in-scanner visual stimulation. 346 Our study was limited by the heterogeneity of the participant population, limited age range 348 (no participants >46 years), and acquisition-related methods that are inherently variable between-and 349 within-participants. Additionally, we did not monitor or control for a number of variables that could 350 alter brain temperature, including circadian rhythms, diurnal changes, hormonal variations (e.g., due 351 to menstruation), or even environmental conditions (e.g., temperature in the scanner room). Our 352 methodological limitations stem from two issues that critically impact all MRSI-t data: 1) magnetic 353 field inhomogeneities and 2) interfering signal from water-containing structures (e.g., the aqueous 354 humor of the eyes). Shimming during EPSI acquisition can substantially reduce magnetic field 355 inhomogeneities and improve signal-to-noise ratio by adjusting spectral linewidth, but the process is 356 time-consuming and difficult without substantial training. Though shimming greatly improves 357 spectral linewidth, it cannot correct the spatial inhomogeneities present across structures and even 358 within large brain regions -additionally, it is unclear whether these spatial inhomogeneities are truly 359 artifact or a reflection of actual physiological processes. Signals from water-containing structures are 360 typically masked with the placement of a saturation band placement during data acquisition. While 361 this is effective to an extent, the saturation band is a 3D rectangular slab of fixed bounds and shape -362 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint it can only be angled to cover the eyes and sphenoidal sinuses, and there is currently no capacity for 363 altering the curvature of the band. Depending on each participant's structural anatomy, the saturation 364 band may cut off regions from regions of cortex in the frontal areas. Additionally, the placement and 365 angling of this slab cannot be replicated from subject-to-subject or even within a subject across time 366 points. As with our own data, these issues can result in missing or even heavily contaminated 367 metabolite and temperature data for impacted ROIs, as voxels may not contain sufficient information 368 or signals of sufficient quality. 369 A countless number of phenomena could theoretically impact brain temperature and weaken 370 the ability to maintain sufficient reproducibility and reliability. Functional activity, time of day, and 371 even transient hormonal fluctuations such as menstruation may impact MRSI-t-based estimates (Ene 372 Mrozek et al. MRSI-t is a reliable and reproducible approach to measuring brain temperature, though future 394 studies of larger sample size with more repeated acquisitions over long duration are necessary. We 395 must also determine whether MRSI-t measurements of brain temperature are sensitive to the 396 phenomenon we are attempting to visualize. Since this study included healthy participants only, the 397 relationship between brain temperature and neuroinflammatory metabolites could not be fully 398 assessed. Thus, the reference data this study provides must be applied to assessing patients with 399 focal neuroinflammation. Before MRSI-t-based temperature can be utilized clinically, it is 400 imperative to determine 1) if this tool can isolate focal brain temperature increases in regions of 401 neuroinflammation and 2) if it can differentiate those with neuroinflammatory pathophysiology from 402 those who are healthy. 403 404 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint De-identified data will be made available upon reasonable request with IRB and data sharing 406 approvals in place. 407 408 All study procedures were approved by the UAB Institutional Review Board. Written informed 410 consent was obtained from all participants before initiating the protocol. 411 412 7 The authors declare that the research was conducted in the absence of any commercial or financial 414 relationships that could be construed as a potential conflict of interest. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint Labeling (AAL) atlas. Brain temperature was derived using the frequency difference between water and creatine (T CRE ) following processing of volumetric MRSI data. For each brain region, colored bars (Time1, teal; Time2, burgundy), reflect the mean T CRE ; whiskers indicate range of T CRE values beyond the mean. The mean global brain temperature over all subjects was 37.2°C with spatial variations across ROIs (37.57 -41.49°C). There was a significant main effect for time (F(1, 1591)=37.0, p < 0.0001) and for brain region (F(46, 1591)=2.66, p<0.0001) . The time*brain region interaction was not significant (F(46, 1591)=0.80, p=0.83) ). Abbreviations: MRSI, magnetic resonance spectroscopic imaging; ROI, region of interest; n, number of observations; R, right; L, left. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint Figure 3 . Representative axial slices showing brain temperature (T CRE) and cerebral blood flow (CBF) for 18 healthy participants at time1 and time 2. T CRE and mean CBF maps were resliced and co-registered to MNI space in SPM12 running in MatLab R2017b. The open-source software MRIcroGL (McCausland Center for Brain Imaging, University of South Carolina; https://www.mccauslandcenter.sc.edu/mricrogl/) was used to overlay mean T CRE and CBF maps on the MNI single-participant template for 3D renderings of participant data. The figure was created using BioRender. All data are visualized for axial view of the same slice (z = 8; L, left; R; right). The T CRE color scale ranges from 36.0 -39°C, with dark to light blue coloring indicating T CRE values within the typical range. The majority of voxels demonstrate T CRE <37.5°C, with a mean of 37.0°C for time1 and 37.4°C for time2 (global mean of 37.2°C). As demonstrated by the time1 and time2 maps and the global COVrep of 1.92%, there was a minimal variation in participants' data from time1 to time2. For some participants' data, brain regions were excluded from analysis due to technical reasons; these areas are represented by regions where the template brain is exposed. Each participant's mean CBF maps for time1 and time 2 are visualized alongside T CRE maps; as with T CRE mean CBF varies little from time1 to time2. Spatial T CRE variations did not vary as a function of cerebral perfusion as indicated by mean CBF. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted October 31, 2020. TMD -total mood disturbance; CBF, cerebral blood flow; tCHO, total choline; tCre, creatine + phosphocreatine (total creatine); NAA/tCre, N-acetylaspartate + N-acetylaspartyl glutamate ratio to tCre; Glx/tCr, ratio of combined signal from glutamine and glutamate to tCre; MI/tCre, myo-inositol ratio to tCre. Table 2 . Mean MRSI-based brain temperature (T CRE ) in 47 ROIs for both time points time1 (T 1 ) and time2 (T 2 ), their standard deviations (SD), and corresponding reproducibility and reliability statistics. For each ROI, reproducibility was measured with the coefficient of variation for repeated measures (COVrep). The standard error of measurement (SEM) provided a measure of reliability. Minimal Detectable Change (MDC) was calculated from SEM to provide a clinically meaningful basis for evaluating T CRE changes over repeated measures. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint T 2 Table 4 . Coefficient of variation (COVrep, %) for major metabolites. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted October 31, 2020. ; https://doi.org/10.1101/2020.10.27.20220715 doi: medRxiv preprint Microglial Activation in Non-neurodegenerative Brain Diseases Cognition in multiple sclerosis: Relevance of lesions, brain 479 atrophy and proton MR spectroscopy Early and protective 481 microglial activation in Alzheimer's disease: a prospective study using 18 F-DPA-714 PET 482 imaging In vivo mapping of brain myo-484 inositol Assessment 486 of human brain temperature by1H MRS during visual stimulation and hypercapnia The role of inflammation in CNS injury and 489 disease Toll-like receptor 491 4 and high-mobility group box-1 are involved in ictogenesis and can be targeted to reduce 492 seizures Comprehensive processing, display and analysis for in vivo MR spectroscopic imaging Reproducibility of serial whole-brain MR 497 Spectroscopic Imaging Effects of tissue susceptibility on brain 499 temperature mapping