key: cord-0296002-zl7kfnlb authors: Mariita, R. M.; Wilson Miller, A. C.; Randive, R. V. title: Disinfection of SARS-CoV-2 using UVC reveals wavelength sensitivity contributes towards rapid virucidal activity date: 2021-07-05 journal: nan DOI: 10.1101/2021.06.30.21259769 sha: 440066c449ba4e3ad5d595457a5821cec9d89ed1 doc_id: 296002 cord_uid: zl7kfnlb SARS-CoV-2 is a pathogen that can be disinfected using UVC. For effective inactivation strategies, design and implementation of UVC disinfection, knowledge of wavelength sensitivity, and disinfection rate of the relevant pathogen are required. This study aimed to determine the inactivation profile of SARS-CoV-2 using UVC irradiation with different wavelengths, in addition to validating surrogate models for SARS-CoV-2. Specifically, the study determined dosage, inactivation levels, and wavelength sensitivity of SARS-CoV-2. Assessment of SARS-CoV-2 (Strain USA/WA1-2020) inactivation at peak wavelength of 259, 268, 270, 275 and 280 nm was performed using plaque assay method. The UVC dose of 3.1 mJ/cm2 using 259 and 268 nm arrays yielded LRV2.32 and LRV2.44 respectively. With a dose of 5mJ/cm2, arrays of peak wavelengths at 259 and 268 nm obtained similar inactivation (LRV2.97 and LRV 2.80 respectively). The remaining arrays of longer wavelength, 270, 275 and 280 nm, demonstrated lower performances (LRV2.0 or less) with 5mJ/cm2. Additional study with the 268 nm array revealed that a dose of 6.25 mJ/cm2 (with 5 seconds or irradiation) is enough to obtain LRV3. These results determine that 259 and 268 nm are the most efficient wavelengths compared to longer UVC wavelengths, allowing the calculation of disinfection systems efficacy, and providing a benchmark for surrogates. (LRV2.0 or less) with 5mJ/cm 2 . Additional study with the 268 nm array revealed that a dose of 6.25 23 mJ/cm 2 (with 5 seconds or irradiation) is enough to obtain LRV3. These results determine that 259 24 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. ; https://doi.org/10.1101/2021.06.30.21259769 doi: medRxiv preprint were used to confirm emitted radiation peak wavelength and UVC dose of the UVC arrays 1 respectively. Experiments were carried out in a biosafety level 4 laboratory of the National 2 Emerging Infectious Diseases Laboratories of Boston University (https://www.bu.edu/neidl/) . 3 Specifically, 100 μL SARS-CoV-2 (7.33 × 10 3 PFU/mL) (USA/WA1-2020) [10] was plated onto 4 the surface of 60 mm plastic coupons (tissue culture dishes) in 5 μL aliquots. The virus was then 5 dried in the biosafety cabinet in the dark before irradiating with UVC LED arrays. 6 A pair of tissue culture dishes (one to be irradiated and one control wrapped tightly in 7 aluminum foil) were placed in the chamber of the device and UVC irradiated for a specified number 8 of seconds, with each irradiation time tested in triplicate and averages used in statistical analyses. 9 Following treatment, the virus was resuspended in 2 mL high glucose Dulbecco's Modified Eagle 10 Medium (DMEM) (Gibco) containing 0.04 mM phenol red, 1 × antibiotic-antimycotic (Gibco), 1 × 11 non-essential amino acids (Gibco), 1 × GlutaMAX-I (Gibco), 1 mM sodium pyruvate (Gibco) and 12 2% fetal bovine serum (FBS)(Gibco). The resuspended virus was then serially diluted from 1 × 10 0 13 to 1 × 10 -2.5 using half-logarithmic dilutions before performing a plaque assay after inactivation 14 with UVC at a specific height, dose and time ( The study developed an irradiation apparatus (Fig 1a) to quantitatively analyze 24 inactivation of SARS-CoV-2 with different wavelengths. A USB4000 photospectrometer (Ocean 25 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. ; https://doi.org/10.1101/2021.06.30.21259769 doi: medRxiv preprint Optics) was used to confirm the emitted radiation peak wavelengths of the UVC LED arrays at 259, 1 268, 270, 275 and 280 nm (Fig 1b) . The UVC dose was confirmed using X1 handheld optometer 2 (Gigahertz-Optik) ( Table 1) . 3 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. CoV-2 at >270 nm compared to 259 and 268 nm. SARS-CoV-2 showed high susceptibility to UVC radiation, especially at peak 21 emissions of 259 and 268 nm (Fig 2) . There was strong association between wavelength and 22 inactivation efficacy of the test arrays. Specifically, within UVC doses of 1.5mJ/cm 2 , 3.1 mJ/cm 2 23 and 5mJ/cm 2 , there were significant differences in inactivation efficacy between arrays (p=0.0245, 24 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. ; https://doi.org/10.1101/2021.06.30.21259769 doi: medRxiv preprint R 2 =0.8551, p=0.0497, R 2 =0.7723 and p=0.0186, R 2 =0. 8788 respectively). Inactivation 1 performances increased with UVC exposure (dose) (Fig 3) . Additionally, because the performance 2 of 259 and 268 nm arrays was similar, the study went further and confirmed that with 6.25 mJ/cm 2 3 in 5 seconds, LRV3 is obtained at 268 nm array. SARS-CoV-2 was reduced to below detectable 4 levels within 7 seconds at a UVC wavelength of 268 nm. CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. Findings from the current study are consistent with previous findings that UVC is very 10 effective at inactivating SARS-CoV-2, that shorter wavelengths are more effective, and reveal the 11 approximate required dosing [1] , [7] . These results are somewhat consistent with a study of 280 12 nm, in which it took 37.5mJ/cm 2 to obtain LRV3 against SARS-CoV-2, in that longer wavelengths 13 were much less effective [12] . For emphasis, shorter wavelengths easily achieve target inactivation 14 with less dose [13] . These findings also support the use of HCoV-43 as a surrogate pathogen to 15 SARS-CoV-2 as used by Gerchman et al., [14] . However, the exact calculation of air disinfection is still not possible because this study only 22 examines SARS-CoV-2 on dried surfaces and does not explore it as either a particulate or 23 . CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted July 5, 2021. ; https://doi.org/10.1101/2021.06.30.21259769 doi: medRxiv preprint aerosolized SARS-CoV-2. Furthermore, SARS-CoV-2 was considered and therefore these results 1 may not be used as baseline for other viruses, especially non-enveloped viruses. These findings also 2 do not account for varied humidity and temperature, nor other types of surfaces. Still, this study 3 allows the design and implementation of many new UVC systems based on the inactivation profiles 4 found for varying UVC radiation sources. 5 6 Our findings provide a basic knowledge that SARS-CoV-2 is more sensitive at shorter 8 wavelengths (<268 nm, as opposed to >270 nm). UVC LEDs with the most effective peak 9 emissions could serve as effective and rapid tools in the fight against SARS-CoV-2 and other 10 pathogenic viruses. This is an important result for designing UVC-based solutions, as engineers 11 need to consider the effectiveness of the wavelengths used and the tolerance around rated peak 12 wavelength and supports the use of HCoV-43 as a surrogate. 13 14 Original SARS-CoV-2 disinfection data and laboratory report is available upon reasonable request. is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 5, 2021. CC-BY-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted July 5, 2021. ; https://doi.org/10.1101/2021.06.30.21259769 doi: medRxiv preprint Susceptibility of SARS-CoV-2 to UV 2 irradiation RNA self-cleavage activated by 5 ultraviolet light-induced oxidation Evaluation of an ultraviolet C (UVC) light-emitting 8 device for disinfection of high touch surfaces in hospital critical areas Using UVC Light-Emitting Diodes at Wavelengths of 11 266 to 279 Nanometers To Inactivate Foodborne Pathogens and Pasteurize Sliced Cheese Sanitizing With Controlled Exposure to UVC Light Evaluation of an ultraviolet C light-emitting device for 17 disinfection of electronic devices Rapid and complete inactivation of SARS-20 CoV-2 by ultraviolet-C irradiation Quantitative evaluation of SARS-CoV-2 23 inactivation using a deep ultraviolet light-emitting diode UVC-based photoinactivation as an efficient tool 26 to control the transmission of coronaviruses. Science of The Total Environment 148548 Severe Acute Respiratory Syndrome Coronavirus 2 29 from Patient with Coronavirus Disease, United States Rapid Quantification and Neutralization Assays for 32 Novel Coronavirus SARS-CoV-2 Using Avicel RC-591 Semi-Solid Overlay Rapid inactivation of SARS-CoV-2 with deep-UV 35 LED irradiation UV-C irradiation is highly effective in 1 inactivating SARS-CoV-2 replication UV-LED disinfection of 4 Coronavirus: Wavelength effect The effect of ultraviolet-C technology on viral 7 infection incidence in a pediatric long-term care facility