key: cord-0292111-cog8a877 authors: Curtis, K.; Gonzalez, R. A. title: Interpreting Wastewater SARS-CoV-2 Results using Bayesian Analysis date: 2021-08-22 journal: nan DOI: 10.1101/2021.08.17.21262165 sha: b7b667b43562790336fc0c30eca5cf4b53ed4fb4 doc_id: 292111 cord_uid: cog8a877 Wastewater surveillance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has proven a practical complement to clinical data for assessing community-scale infection trends. Clinical assays, such as the CDC-promulgated N1, N2, and N3 have been used to detect and quantify viral RNA in wastewater but, to date, have not included estimates of reliability of true positive or true negative. Bayes Theorem was applied to estimate Type I and Type II error rates for detections of the virus in wastewater. Conditional probabilities of true positive or true negative were investigated when one assay was used, or multiple assays were run concurrently. Cumulative probability analysis was used to assess the likelihood of true SARS-CoV-2 detection using multiple samples. Results demonstrate highly reliable positive (>0.86 for priors >0.25) and negative (>0.80 for priors = 0.50) results using a single assay. Using N1 and N2 concurrently caused greater reliability (>0.99 for priors <0.05) when results concurred but generated potentially counterintuitive interpretations when results were discordant. Regional wastewater surveillance data was investigated as a means of setting prior probabilities. Probability of true detection with a single marker was investigated using cumulative probability across all combinations of positive and negative results for a set of three samples. Findings using a low (0.11) and uniformed (0.50) initial prior resulted in high probabilities of detection (>0.95) even when a set of samples included one or two negative results, demonstrating the influence of high sensitivity and specificity values. Analyses presented here provide a practical framework for understanding analytical results generated by wastewater surveillance programs. Bayes' Theorem was applied to estimate Type I and Type II error rates for detections of the virus in 23 wastewater. Conditional probabilities of true positive or true negative were investigated when one 24 assay was used, or multiple assays were run concurrently. Cumulative probability analysis was used to 25 assess the likelihood of true SARS-CoV-2 detection using multiple samples. Results demonstrate highly 26 reliable positive (>0.86 for priors >0.25) and negative (>0.80 for priors = 0.50) results using a single 27 assay. Using N1 and N2 concurrently caused greater reliability (>0.99 for priors <0.05) when results 28 concurred but generated potentially counterintuitive interpretations when results were discordant. 29 Regional wastewater surveillance data was investigated as a means of setting prior probabilities. 30 appropriate interpretation of results with respect to confidence or probability. . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The posterior probability that SARS-CoV-2 is present in a sample given detection of each assay (N1, N2, 118 N3) was tested across all possible priors (0.0-1.0) using Equation 1. A similar conditional probability was 119 derived to test the likelihood that SARS-CoV-2 is absent from a sample given a negative assay result and 120 was also tested across all priors. 121 As noted, the specificity of the N1 and N2 assays determined by Lu et al. were 1.0. A specificity value of 122 1.0 guarantees the absence of false positive results regardless of assay sensitivity and prior probability. 123 As a result, it is difficult to observe the effect of differing approaches for setting priors and the 124 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. ( 2 + | 1 + ∩ 2 + ) = 1 * 2 * ( 2 + ) 1 * 2 * ( 2 + ) + (1 − 1 ) * (1 − 2 ) * ( 2 − ) . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. CoV-2 presence was calculated for wastewater samples using N2 alone and N1 and N2 concurrently. For 157 samples that were negative for N2 or both N1 and N2 the posterior probability that SARS-CoV-2 is 158 absent in a given wastewater sample was reported. 159 160 The cumulative probability of SARS-CoV-2 based on results from three separate samples was 162 investigated for two scenarios representing a comparatively low and high initial prior. The low initial 163 prior (0.11) was based on the lowest possible non-zero value for percent positive treatment facilities (1 164 of 9 facilities with a detection) in the Hampton Roads wastewater surveillance network. The high initial 165 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. that when N1 or N2 are used, a positive analytical result is highly reliable (>0.97), even at priors below 184 0.05. While not as overwhelming as N1 or N2, the N3 assay also generated highly reliable positive 185 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. The copyright holder for this preprint this version posted August 22, 2021. ; https://doi.org/10.1101/2021.08.17.21262165 doi: medRxiv preprint likelihood of false positive results for N3 was expected given the slightly lower specificity (0.955). As 187 described by Lu et al., the N3 assay was intentionally designed to also detect SARS-CoV, resulting in a 188 lower specificity value when cross-reactivity was tested against closely related respiratory viruses. The 189 likelihood of obtaining a true negative result was high with all assays when SARS-CoV-2 was absent 190 2). When both assays detect the virus there is an exceedingly high probability (>0.99) that this detection 203 is reliable, even at very low priors (0.005). Similarly, when either assay is used individually and detects 204 the virus, these results are also highly reliable, as described in the previous section. Discordant results 205 (N1+/N2-or N2+/N1-) using two assays also yields a high probability that SARS-CoV-2 is present (>0.87), 206 even when priors are low (0.05). This is a potentially counterintuitive result which requires an 207 understanding of test characteristics (sensitivity and specificity) as well as the effect of prior probability 208 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. results are highly reliable for all samples, regardless if one or both assays were used (Fig 3) . These 228 findings suggest that a single assay likely provides sufficient confidence in positive results when 229 detections are routinely seen at monitored facilities, causing priors to be set relatively high. 230 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Finding conflicting results when running multiple assays in the context of higher, wastewater-246 derived priors also produces potentially difficult to interpret results. For the range of wastewater-247 derived priors tested (0.39-1.0), discordant results regardless of which assay was detected, provide 248 strong evidence that SARS-CoV-2 is present ( Figure 3 ). As described above, failing to consider prior 249 probability of detection could lead a researcher to interpret conflicting results as a 0.5 likelihood that 250 SAR-CoV-2 RNA is present in the sample. Interpretation using a Bayesian framework would suggest that, 251 even at the lowest prior for which there were conflicting results (0.56), the likelihood that the virus is 252 present is >0.99. 253 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. Applying a Bayesian framework for interpreting analytical findings is fundamentally driven by the 297 sensitivity and specificity values assigned to the assays in question, along with the assumed prior. As a 298 result, the accuracy of these values is highly consequential for the analysis. For this preliminary exercise, 299 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. specificity testing using their own analytical methodology performed on the matrix being studied to 306 derive lab-specific specificity values. A similar recommendation is suggested for deriving lab-specific 307 sensitivity values and is likely more impacted by wastewater matrix effects such as inhibition. 308 After establishing assay sensitivity and specificity, prior probability is the final value required to conduct 309 the simple conditional probability analyses described above. Prior probability is another critical piece of 310 this framework as it also exerts a significant influence on the outcome and the process for setting a 311 value may not be intuitive. Establishing the prior probability of an event or result can be challenging 312 when little is known about the system being studied. Regarding wastewater-based epidemiology one 313 suggested approach for estimating prior probability of SARS-CoV-2 detection is to use recent results 314 from the same location (e.g., the proportion of positive results from the last set or sets of samples) or 315 results from other areas within a common region. Priors may also comprise a distribution, allowing for 316 some incorporation of uncertainty. For instance, noting that clinical cases in the area of study have 317 been increasing rapidly in the preceding weeks does not suggest a specific value for use as a prior 318 probability but does provide information which should not be ignored when assessing reliability of 319 wastewater detections. Integrating this clinical information into a Bayesian analysis of wastewater 320 results might include setting priors using a uniform distribution of 0.51-0.99, implying that little is known 321 about the true prior probability of SARS-CoV-2 detection, but regional case data suggests that a 322 . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 22, 2021. ; https://doi.org/10.1101/2021.08.17.21262165 doi: medRxiv preprint CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 22, 2021. ; https://doi.org/10.1101/2021.08.17.21262165 doi: medRxiv preprint . CC-BY-NC-ND 4.0 International license It is made available under a is the author/funder, who has granted medRxiv a license to display the preprint in perpetuity. (which was not certified by peer review) The copyright holder for this preprint this version posted August 22, 2021. ; https://doi.org/10.1101/2021.08.17.21262165 doi: medRxiv preprint An Interactive Web-Based Dashboard to Track COVID-19 in Real 346 Wastewater-based epidemiology: global collaborative to maximize 350 contributions in the fight against COVID-19.Been, Prosun Bhattacharya, Lubertus Bijlsma Probabilistic analysis showing that a combination of Bacteroides and Methanobrevibacter source 370 tracking markers is effective for identifying waters contaminated by human fecal 371 pollution. Environmental science & technology Integrating Bayesian Analysis and Cumulative Probability Generates High Confidence Using a Single Microbial Source Tracking Marker. Environmental science 374 & technology Integrating metagenomic and Bayesian analyses to 376 evaluate the performance and confidence of CrAssphage as an Indicator for tracking human sewage 377 contamination in China Wastewater Analysis of SARS-CoV-2 as a Predictive 380 Metric of Positivity Rate for a Major Metropolis Long-term monitoring of SARS-CoV-2 RNA in 382 p COVID-19 surveillance in Southeastern Virginia using 394 wastewater-based epidemiology Microbial source tracking 396 markers for detection of fecal contamination in environmental waters: relationships between 397 pathogens and human health outcomes Distributions of fecal 399 markers in wastewater from different climatic zones for human fecal pollution tracking in Australian 400 surface waters Application of a microbial source tracking based on bacterial and chemical 403 markers in headwater and coastal catchments Multiple assays in a real-time RT-PCR SARS-CoV-2 panel can mitigate the risk 406 of loss of sensitivity by new genomic variants during the COVID-19 outbreak