key: cord-0291891-sq8jisf5 authors: Li, Hongquan; Krishnamurthy, Deepak; Li, Ethan; Vyas, Pranav; Akireddy, Nibha; Chai, Chew; Prakash, Manu title: Squid: Simplifying Quantitative Imaging Platform Development and Deployment date: 2020-12-29 journal: bioRxiv DOI: 10.1101/2020.12.28.424613 sha: 04dae93d8b8daf018bb70a48e84ef660137127da doc_id: 291891 cord_uid: sq8jisf5 With rapid developments in microscopy methods, highly versatile, robust and affordable implementations are needed to enable rapid and wide adoption by the biological sciences community. Here we report Squid, a quantitative imaging platform with a full suite of hardware and software components and configurations for deploying facility-grade widefield microscopes with advanced features like flat field fluorescence excitation, patterned illumination and tracking microscopy, at a fraction of the cost of commercial solutions. The open and modular nature (both in hardware and in software) lowers the barrier for deployment, and importantly, simplifies development, making the system highly configurable and experiments that can run on the system easily programmable. Developed with the goal of helping translate the rapid advances in the field of microscopy and microscopy-enabled methods, including those powered by deep learning, we envision Squid will simplify roll-out of microscopy-based applications - including at point of care and in low resource settings, make adoption of new or otherwise advanced techniques easier, and significantly increase the available microscope-hours to labs. To simplify development and allow rapid configuration for various applications, we created a full-suite of microscope building blocks ( Figure 1 ). We chose to use off-the-shelf components and CNC machined parts to optimize for performance, quality control and ease of assembly. By designing the blocks ground up from these components with the goal of meeting broad microscopy use needs (but not trying to meet all possible needs), we reduced the cost by a factor of 10 to 50 compared to commercial counterparts, lowering the cost and access barrier to high performance imaging systems. The microscope system can be controlled by any computer running Ubuntu (preferred) or Windows, including embedded computers like the Nvidia Jetson family. An Arduino Due is used for interfacing a control-panel, as well as for low-level control of motion, illumination, hardware camera triggers and other applications where high timing resolution and accuracy is necessary. The Arduino Due and the computer communicate through USB-based virtual COM port at 2 Mbit/s. PCB boards are implemented to allow robust integration of different electronic components. Currently a stackable, modular design is used to allow sequential development and future expansion of functionalities. Already implemented boards include a processing plane for interfacing the Arduino Due, a motion plane with 4 TMC2209 Silent Step Stick stepper motor drivers, as well as a board for the control panel and a board for interfacing the motion plane with encoders and limit switches. Notably, the driver stack can be used to support any motorized stages that are stepper motor-based. Illumination boards with 6 laser diode drivers (using TI DAC80508, a 8-channel 16 bit DAC and Wavelength Electronics laser diode drivers) and 6 LED drivers (using TI TPS92200) are currently being designed (a 8-channel DAC Arduino shield based on TI DAC8568 is also available from [121] ). The board will include SMB interfaces to allow control of other commercial laser and LED engines. While some of the modules presented in Figure 1 will be described in more detail in the following sections, Figure 2 shows some example optical configurations that can be implemented. So far we have several implementations based on Figure 2 A, B, E for a variety of applications ranging from long term imaging, plate reading, multi-color fluorescence imaging of pathology specimens to tracking microscopy, and are currently bringing online implementations based on Figure2 F and G to extend high-speed tracking to 3D. To supplement the modular hardware suite, we have developed a highly modular, object-oriented, python-based control software (with code-structuring inspiration from [3] , which is based on [140] ). The code is divided into drivers (for cameras, microcontroller and and other devices that may need to interface directly with the computer), core functionalities implemented as controllers (e.g. camera stream handler, threaded image saver, live controller that controls the current microscope mode and its settings, configuration manager that manages loading, updating and saving of microscope configurations; core functionalities also include application specific controllers, e.g. for tracking and for multi point acquisition), widgets that serve as interfaces between the user and the functionalities, and a top level GUI that instantiates different controllers and widgets and links the objects together. This approach to software has made it very easy to switch between microscope hardware configurations as well as further expand functionalities. Figure 3 and Supplementary Video 1 show an example of one graphical user interface. One central piece available from the suite of building blocks is the motorized focus block ( Figure 1A ), which is constructed with a ball bearing linear stage with a coupled linear actuator. A piezo stack is optionally inserted between the stage and the shaft of the linear actuator to allow nm resolution focus adjustment. The use of a Thorlabs lens tube clamp for mounting an optical train (objective, imaging lens, cameras and necessary adapters for connecting them) makes it easy to quickly switch between different optical trains without taking apart the assembly, where Thorlabs SM1 lens tube and the associated adapters allow most objectives to be mounted. For more complex optical trains, the block provides direct mounting of cage cubes ( Figure 1B) , which decouples the objective from the rest of the optical train, allowing the objective to be moved for focus adjustment while other components remain stationary, similar to what's in commercial microscope bodies. The focus block can be mounted either through a post mounting clamp to a 1.5" diameter post, or on a machined structure for easily and robustly integrating with longer downstream optical paths or more sophisticated optical setups. Characterization of the motorized focus block shows sub-200 nm resolution with 1/8-microstepping and good open-loop repeatability (Supplementary Figure 1A-H) . We note that when doing z-stack in open-loop, to achieve good repeatability and uniform step size allowed by the mechanics, a back-and-forth maneuver is needed to counteract mechanical backlash in the linear actuator ( Figure 1I -L), which is present despite the actuator being spring-loaded by the linear stage. We also found that due to the mechanical backlash and limitation of lead screw accuracy, rotary encoders have very limited utility in this application ( Figure 1A -K). To support closed-loop positioning for improved accuracy and repeatability, we're currently integrating an optical encoder that supports 5 nm resolution and can be used for homing purpose (Supplementary Figure 2) . In the characterization experiments, we also show that the focus stage can move at speed of at least 5 Hz with 180 m peak-to-peak amplitude (sinusoidal) when driven by the linear actuator and 30 Hz with 2.5 m peak-to-peak amplitude (sinusoidal) when driven by the piezo stack (limited 140 mm x 80 mm travel motorized XY stage with a well plate adapter (E) A typical image formation assembly with an industrial camera and a machine vision imaging lens (F) Flat field laser epi-illumination module (G) Flat field LED epi-illumination module (H) LED matrix trans-illuminator (I) Control panel with an analog joystick, a focusing knob, a toggle switch and two rotary potentiometers. Currently the toggle switch is used for enable tracking (when implementing tracking microscopy) and one of the potentiometers is used to adjust the XY stage max speed. (J) Driver stack (shown also a Jetson Nano for running the microscopes in place of a laptop or desktop computer) (K) One example configuration: upright microscope for reading a 96-well plate (termed Nautilus from here on-wards, see also [119] ) (L) Second example configuration: multi-color flat field epifluorescence microscope with simultaneous transmitted light channel (e.g. for tracking microscopy). Various other configurations are described throughout the paper. by the travel of the piezo stack; a longer piezo stack with larger travel, e.g. Thorlabs PK2FSF1 that has 220 m free stroke, can be used if necessary). For applications where faster scanning or scanning a larger range is needed, remote focusing with a tunable lens or a higher speed stage is more suitable [141] . We also measured z-drift over more than 30 hours and found the [40, 44] or waveguide illumination. (B) A single camera configuration with epifluorescence illumination. By using multiband filters and dichroics or a color camera [44] , multicolor fluorescence microscopy can be achieved. The same camera is also used for non-fluorescence contrasts. (C) A single camera configuration with both epifluorescence illumination and a reflection-based focus stabilization system (e.g. [3, 7, 122, 123] ). The second dichroic filter can be a 775 nm short pass dichroic. Alternatively, if bead fiducials can be introduced, the laser can be replaced with an IR LED above the sample to limit the drift to below 1 nm across all three dimensions [124] [125] [126] [127] . (D) Another camera is added so that two or more fluorophores can be imaged at the same time [128] [129] [130] [131] . Depending on fluorophores, filters and dichroics, either one or two lasers can be on for simultaneous multicolor fluorescence. (E) A two camera configuration with epifluorescence, where one camera is for tracking with IR illumination. (F) A three camera configuration with two cameras for both in plane and focus tracking. A mirror that divides the aperture into two cameras is used to manifest defocus as image shift. (G) A three camera configuration where one camera is used with an electrically tunable lens for volumetric imaging and focus tracking. For the arm with electrically tunable lens, a 4f system can be used to place the tunable lens at the imaged back focal plane of the objective so that there's no magnification change when focus is swept. Alternatively, a z-splitter may be used to trade off FOV or spatial resolution with temporal resolution with one [124, [132] [133] [134] or multiple cameras [135] [136] [137] [138] [139] . Note all configurations can be upright, inverted, or horizontal for vertical tracking microscopy [54] . likely temperature-correlated drift to be ă 1 m. A motorized XY stage with 28 mm x 28 mm travel is constructed similarly to the z-axis stage ( Figure 1C ). Currently we're using a NEMA-8 linear actuator with 5 full step size, which allows max speed of about 10 mm/s. The max speed may be increased to 120 mm/s by switching to larger NEMA 11 or 14 linear actuator, reducing the spring constant of the springs in the ball bearing XY stage, increasing the drive current of the linear actuator or a combination of these. A sample holder was designed for mounting standard glass slides, cover slips and petri dishes. This module can be directly mounted on a 1.5" post, which in the inverted configuration, can be the same post used for the focus block. For applications that requires larger travel, we have made use of linear guide rails-based, ball screw driven motorized stages ( Figure 1D ) and lower cost lead screw driven motorized stages [54] . We did find parallelism performance issue for the ball screw driven stage employing a NEMA 8 stepper motor and in future revisions we will use stages with cross roller bearings. Given the unique construction of the microscope ( Figure 1K -L) -including the way lenses and cameras are mounted ( Figure 1E ; also discussed in the next section), and that the microscope may not sit on an optical table, we set out to characterize the stability of the system and its immunity to vibrations, if any. We did so by imaging single or clusters of 83 nm diameter YG fluorescent beads (Polysciences, cat# 17150-10) with a 60x/1.49 NA objective. When the breadboard sits directly on a table, we did observe oscillation at around 60 Hz with peak to peak amplitude of around 40 nm (Figure 4 A,B). Adding 4 sorbothane feet (Thorlabs AV3) underneath the breadboard effectively suppressed the oscillation (Figure 4 B,C). Another building block extensively used in different configurations is the imaging lens + camera assembly, which consists of a machine vision lens and an industrial camera. The industrial cameras uses the latest generations of CMOS sensors with convenient USB3, GigE or MIPI interfaces. A wide range of sensors with different number of pixels, pixel size, frame rate, shutter (rolling vs global) can be selected based on applications. The smaller pixel size allows use of lens of shorter focal length (50 mm or 75 mm as compared to 165 mm -200 mm) for image formation, making the system more compact. While commercial tube lenses at these focal length does not currently exist, high resolution (5 MP-20 MP) machine vision lenses properly corrected for different aberrations are available at relative low cost ($100-$500). To compare the performance of our imaging lens + camera assembly with its counterpart in commercial setups, we imaged the same region of cells with labeled cDNA amplicons with a f = 200 mm tube lens that's part of a Nikon Ti2 microscope + a Prime 95B sCMOS camera (2.6 MP, 11 um pixel size) and a f = 50 mm machine vision lens (HIKROBOT MVL-HF5028M-6MP) with an industrial camera (Daheng Imaging MER-1220-32U3M) using Sony IMX226 (12 MP, 1.85 um pixel size), using the same exposure time. For the Prime 95B, an additional 1.5X magnification is used so that the objective side pixel size is similar to that of the Sony IMX226 (122 nm vs 127 nm). For the Sony IMX226, a 4f system is used to bring the back focal plane of the objective outside the microscope body so that the f = 50 mm imaging lens can be used. Figure 5 shows that an industrial CMOS camera paired with a high resolution imaging lens can deliver results as good as from the much more expensive commercial counterparts (see [19, 88, 125, 135, [142] [143] [144] for more studies comparing the use of an industrial CMOS sensor vs the use of an sCMOS or EMCCD). A Prime 95B + Ti 2 tube lens w/1.5x B Sony IMX226 + 50 mm imaging lens The wide range of available industrial CMOS sensors makes it possible to choose a camera with a suitable sensor for a given imaging experiment. For example, we used a camera with an On Semiconductor Python 300 sensor supporting 860 fps with a 100x/1.25 oil objective to image three different ultrafast events in Vorticella sp. (Figure 6, Supplementary Video 2) . The same camera and other global shutter CMOS cameras with selectable ROI (e.g. IMX250) can be used for high speed volumetric imaging or focus tracking when combined with a tunable lens. In another setup, we took advantage of the Sony IMX250MZR sensor with integrated polarizers on top of pixels to perform single shot polarization imaging (Supplementary Figure 4) , which would otherwise require a more complex setup [145, 146] . This same polarization camera can be used for volumetric imaging of intrinsic density, anisotropy, and 3D orientation of cell and tissue components [66, 67] . To allow programmatically controlled illumination (not only intensity but also NA and angles) [57] and fast single or two-shot autofocus [150] , we implemented an illuminator consisting of an 8x8 programmable LED array and a condenser with a diffuser surface (Figure 1 H, Figure 7 ). This illuminator and its variations (e.g. LED matrix with more LEDs, LED ring) may be used to enable techniques including quantitative phase imaging, intensity diffraction tomography and Fourier ptychographic microscopy. Other illumination modules that have been used in these applications can also be adopted [57, 61, 69, 151, 152] . We are further incorporating an LCD-TFT display for finer control of the illumination, which can be used in recently developed techniques in quantitative phase imaging [59, 67] . Multicolor flat-field epifluorescence illumination is desirable in many applications. To make this feature more readily accessible, building on top of others' work [18, 153, 154] , we have developed an easy-to-integrate flat field launch using square core Figure 8 A inset) and a low-cost (about $1000), compact and alignment-free multi-color laser engine (Figure 8 A) . Because the magnified image of square fiber core (formed by the 80x objective) is imaged into the infinity space of the imaging objective, translation of the objective or switching objectives would not affect the image of the fiber (the illumination profile) in the object plane. By adding a translation module, TIRF and HILO (highly inclined and laminated optical sheet) [155] illumination can be achieved. Using 105 m multimode fiber pigtailed laser diodes in our laser engine and a quad band filter set, we are able to get 43.3 mW of 638 nm, 12.4 mW of 488 nm and 10.3 mW of 405 nm excitation at the object plane of a Nikon 20x/0.75 apochromatic objective (for the second laser engine we constructed, we're able to get 60.6 mW of 638 nm, 23.6 mW of 488 nm and 20.3 mW of 405 nm after a 4x achromatic objective, and 58.9 mW of 638 nm, 19.5 mW of 488 nm and 12.8 mW of 405 nm after a 10x achromatic objective). To increase the laser power, besides choosing laser diodes with higher output power (e.g. a 700 mW laser diode at 638 nm is readily available from the same supplier), additional laser diodes can also be added. As for 561 nm, we have evaluated a compact, frequency doubled quantum dot laser from QDLaser with up to 15 mW output in single mode fiber (versions with 25 mW output using a multimode fiber and 50 mW free space output also available), which can be directly modulated up to 100 MHz -an advantage over diode pump solid state (DPSS) lasers frequently used at this wavelength. We have also recently identified a lower cost ($ 1200), 150 mW fiber-coupled Nd:YVO4 DPSS laser with PPLN intracavity frequency doubling and will be evaluating it soon. Currently, speckle reduction is implemented with shaking an inserted section of multimode fiber with a coin vibrator (15000 rpm), which performs well (Figure 8 B-E) but can also be further improved, especially for the more coherent 561 nm line. As an example application, we imaged two CODEX-processed samples (Figure 8 F-G, Supplementary Video 3) , where z-stacks (17 planes, 1.5 m spacing) were taken and the results are deconvolved with an unmatched back projector [77] . We note that using the laser engine and flat field launch, HiLo microscopy [156, 157] can be readily applied, although the requirement of speckle being fully developed for the speckle image will limit the imaging speed for multicolor acquisition as the laser diodes are currently switched on/off directly. To break this limit without requiring expensive electrical or acoustic modulators (or requiring the lasers to be free-space coupled so that mechanical shutters can be used), additional dichroic beam splitter and detection paths can be added so that multiple lasers can remain on at the same time. For applications requiring single spatial mode (e.g. light sheet generation), single mode pigtailed laser diodes or modules and single mode fiber combiners are also readily available. As an alternative to laser-based illumination, we have also implemented LED-based flat field illumination ( Figure 9 ). Because of the large étendue of LED source, only a small fraction of optical power will be delivered to the object plane. Using a Thorlabs M405D2 at 1.2A driving current, which results in > 1.5 W emitted optical power, we're able to get 64 mW at the object plane after a 10x/0.25 NA objective, for illuminated area of 1.65 ˆ1. 65 . Multiple LEDs can be combined with light delivered [77] to the microscope in free space or through a liquid light guide (many customizable off-the-shelf solutions are already available, e.g. from Prizmatix and bluebox optics). Higher power LEDs (>10W optical power at the LED) widely used in 3D printing and projectors are available at low cost, and can be used if appropriate heat sink is implemented. Further more, using the configuration in Figure 2B , we demonstrated patterned illumination with a DLP projector ( Figure 10) , which, along with its LCoS alternatives, may be used to perform targeted photo-stimulation [24] [25] [26] [27] 158] and structured illumination for optical sectioning and/or super resolution [19, 21, 25, 52, 137, 159, 160] . Alternatively, lasers may be used in place of the LED for higher efficiency or for coherent SIM [20, [161] [162] [163] [164] . In applications where laser lines at 450 nm, 520 nm and 640 nm suffice, RGB laser projectors may be used for compact integration. Conventional, fixed field-of-view (FOV) microscopy techniques are not suitable for studying live, highly motile, suspended organisms capable of complex and fast movements. To image these cells during unrestrained behavior, one is forced to sacrifice optical resolution to gain a larger FOV. Tracking microscopy is a valuable method that solves this challenge by continuously re-positioning the sample stage or imaging system to keep the tracked organism within the microscope FOV. This allows one to obtain sub-micron resolution images of an organism while allowing unrestrained behavior over scales much larger than the organism's size [51] [52] [53] [54] 165] . By incorporating software elements we had previously developed [54] , we imparted our Squid's with tracking capabilities. Since the software was written in python, it is straightforward for us to integrate state-of-the-art deep learning-based computer vision trackers [166] to allow fast, robust tracking even in complex and crowded environments. We demonstrate tracking microscopy with Squid by measuring tracks of organisms over a wide range of sizes (10 to 1000 ) and diverse behaviors. In particular, we tracked small flagellates such as Chlamydomonas, fast-swimming ciliates including T. pyriformis, Didinium sp. and the giant ciliate S. ambiguum (Figure 11, Supplementary Video 4) . In all cases across diverse sizes, shapes and behaviors of the organisms, we demonstrate successful tracking and obtained trajectories at high spatio-temporal resolution while concurrently obtaining high-resolution dark-field images. While dark-field is the imaging mode shown here, it is possible to combine tracking with any of the microscope configurations described in previous sections. We further characterized the tracking performance in the experiments by calculating the distribution of tracking errors over thousands of images. The distributions (Figure 12 B-E) show that even during complex, fast swimming behaviors the tracking error remains well within the microscope FOV indicating successful tracking. Further, we demonstrate the robustness of the tracking system in complex, crowded environments by tracking a single T. pyriformis cell in a dense culture. Figure 12 F, G and H show the remarkable performance of the combination of both hardware and software tracking systems that are able to follow the given cell of interest in a highly-crowded environment despite multiple crossing and occlusions by cells of similar size, shape and swimming behaviors. In this preprint we described Squid -a modular platform for widefield research grade microscopes that are affordable -and present some of its technical capabilities and flexibility by demonstrating a wide variety of configurations. We also document the construction on our website at https://www.squid-imaging.org. With its high modularity, components of its hardware and software may be either built/used as is or integrated into existing solutions. While we provide a full suite of modules for a wide range of applications, users can also take advantage of other open source modules or commercially available products (motorized stages, lasers, LED engines etc.). The presented mechanical construction of Squid assumes use of compact and light weight industrial CMOS cameras, which have satisfactory performances in many applications [19, 125, 135, 137, [142] [143] [144] and can be further enhanced by generic denoising [149] or automatic correction of CMOS-related noises [88] . In applications where bulkier EMCCD or sCMOS camera are desirable or must be used (for example when the speed of the CMOS rolling shutter needs to be controlled to synchronize camera exposure with light sheet movement [30, 31, 167, 168] ), additional CNC machined parts can be designed to provide needed alignment aid and mechanical support. Squid provides a framework and the set of components for users to implement microscopes that can be tailored to specific applications with reduced budget, effort and turnaround time. With starting cost of less than $2000 (Supplementary Table 1) , which includes full motorization and may be further reduced through optimization, the microscope can deliver functionalities and performances of commercial options that are 10 to 50 times more expensive. The developed motorized XY ($500) and Z stages ($300-$700 depending on encoder option), fiber coupled laser engine ($1000 for 405 nm + 488 nm + 638 nm, starting at $2000 for 405 nm + 488 nm + 561 nm + 638 nm) and tested lens and camera options (starting at $420 for a 12 MP CMOS camera and a 10 MP rated f=50 mm lens) also provide considerable cost reductions for home-builders. Beyond cost saving, high performance and versatility that have been described, Squid is designed to be easy to assemble -even the most sophisticated implementation reported in this preprint can be put together from individual parts and brought online within a single day. The constructed microscope has a small footprint, does not require an optical table to operate, and can be easily transported not only within labs but also to field sites. The open nature and standard interfaces also simplifies future expansion. Because the user has full control of the Arduino-based firmware and Python-based software, it's straightforward to further customize the system and include additional functionalities. These attributes of Squid make it an ideal candidate for greatly increasing the accessibility of high performance research microscope as well as for rapid dissemination and adoption of wide ranging new developments in microscopy and microscopy-based techniques and otherwise advanced features that would require additional premiums in commercial solutions. While 3D printing has been widely taken advantage of in democratizing open source tools [47, 49, 50] , for custom parts we deliberately choose to use CNC machining, which often requires parts to be ordered from vendors but offers exceptional mechanical properties, tight tolerances at price point not much more expensive than 3D printing, esp at qty greater than 5. We use Thorlabs cage and lens tube systems so that users can take advantage of their wide selection of off-the-shelf components and build the microscope with as little need in alignment as possible. Bill of Materials (Supplementary Table 1 -3) and 3D CAD files can be accessed on our website (https://www. squid-imaging.org). The firmware that currently runs on an Arduino Due is developed with the Arduino IDE, using libraries including TMCStepper, AccelStepper, DueTimer and Adafruit_DotStar. In a future version, stepper control will be moved to hardware using stepper controller ICs (Trinamic TMC4361A). The software that runs on the host computer is written in Python and uses libraries including pyqt5/pyside2, pyqtgraph and opencv. A microcontroller class is implemented in microcontroller.py to handle communications with the Arduino Due. Controllers are implemented in core.py. Widgets that wrap around the controllers for the graphical user interface are implemented in widgets.py. Different objects that together constitute the control program are instantiated and connected in gui.py. Software (firmware included) can be found at https://github.com/hongquanli/octopi-research. The illumination profile at the sample is measured using highly concentrated fluorescent dye samples [169] , as previously described [170] . For 488 nm, 561 nm and 638 nm, we used Fluorescein Sodium Salt (FSS) (Sigma Aldrich 46970, for 488 nm excitation) and Acid Blue 9 (AB) (Tokyo Chemical Industry America, 3844-45-9, for 561 nm and 638 nm excitation). 0.9g of FSS and 0.7g of AB were dissolved in 1 ml of deionised water each to prepare separate stocks in eppendorf tubes. The eppendorfs were first vortexed and then left in an ultrasonic water bath overnight to let the smaller particles of the dyes dissolve completely. The next day, a 40 L droplet was placed on a 25 mm by 40 mm coverslip and then gently covered with a 25 mm by 25 mm coverslip. The edges of the coverslip were sealed with nailpolish resin to prevent any evaporation of the solvent. For 405 nm, we used undiluted 10 mg/ml Hochest 33342 solution in water (Invitrogen H3570). For pattern projection we used an EKB DLP E4750RGBLC Light Control evaluation module (DPM-E4750RGBHBLCOX), with an ND = 6 absorptive filter (Thorlabs NE60A-A), and a 50:50 beam splitter (Chroma 21014-UF2). For projection with certain wavelengths, we will be using a variant from EKB with fiberlight guide coupling (EKB DPM-E4750LCFCSOXLLG). The tonsil samples were obtained from Stanford Pathology and were fully de-identified, thus the study was exempt from ethics approval (no human subjects research). The TMA was obtained from another study [171] . Deconvolution was done using MATLAB programs provided with [77] . Point spread functions were generated using FIJI plugin PSF Generator using the Richard & Wolf 3D Optical Model [172] . Vorticella sp. samples were collected from debris clusters growing along with the Didinium sp. cultures obtained from Carolina biological supply for the tracking experiments. The clusters were isolated from the debris using pipetting and then enclosed into a coverslip chamber (20 mm diameter, 0.12 mm depth) constructed using a coverslip spacer (Grace Biolabs). All tracking experiments were done in chambers 20 mm in diameter and 0.12 mm deep constructed using cover slip spacers (Grace Biolabs). Organisms were obtained from Carolina biological supply and were stored at room temperature ( [173] , which allowed tracking at 200 Hz. Homogeneous Multifocal Excitation for High-Throughput Super-Resolution Imaging Nanometer-scale Multiplexed Super-Resolution Imaging with an Economic 3D-DNA-PAINT Microscope Stable stimulated emission depletion imaging of extended sample regions 3D single-molecule super-resolution microscopy with a tilted light sheet easySTORM: a robust, lower-cost approach to localisation and TIRF microscopy Enhanced photon collection enables four dimensional fluorescence nanoscopy of living systems 3D Multicolor Nanoscopy at 10,000 Cells a Day Visualisation of dCas9 target search in vivo using an open-microscopy framework Automated highly multiplexed super-resolution imaging of protein nano-architecture in cells and tissues Ultra-high resolution 3D imaging of whole cells Implementation of a 4Pi-SMS super-resolution microscope Nanometric axial localization of single fluorescent molecules with modulated excitation SIMPLE: Structured illumination based point localization estimator with enhanced precision Molecular resolution imaging by repetitive optical selective exposure Localization microscopy at doubled precision with patterned illumination MINFLUX nanoscopy delivers 3D multicolor nanometer resolution in cells Cost-efficient open source laser engine for microscopy DMD-based LED-illumination super-resolution and optical sectioning microscopy Video-rate multi-color structured illumination microscopy with simultaneous real-time reconstruction Imaging tissues and cells beyond the diffraction limit with structured illumination microscopy and Bayesian image reconstruction Artifact-free whole-slide imaging with structured illumination microscopy and Bayesian image reconstruction The smfBox is an open-source platform for single-molecule FRET Ultrawidefield microscope for high-speed fluorescence imaging and targeted optogenetic stimulation Compressed hadamard microscopy for high-speed optically sectioned neuronal activity recordings Wide-area all-optical neurophysiology in acute brain slices Simultaneous voltage and calcium imaging and optogenetic stimulation with high sensitivity and a wide field of view Imaging multicellular specimens with real-time optimized tiling light-sheet selective plane illumination microscopy A Versatile Tiling Light Sheet Microscope for Imaging of Cleared Tissues Light-sheet microscopy of cleared tissues with isotropic, subcellular resolution The mesoSPIM initiative: open-source light-sheet microscopes for imaging cleared tissue AndrewGYork/high_na_single_objective_lightsheet: Work-in-progress Epi-illumination SPIM for volumetric imaging with high spatial-temporal resolution Multi-immersion open-top light-sheet microscope for high-throughput imaging of cleared tissues Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0 Universal light-sheet generation with field synthesis A versatile Oblique Plane Microscope for large-scale and high-resolution imaging of subcellular dynamics High-Resolution, Large Field-of-View, and Multi-View Single Objective Light-Sheet Microscopy Real-Time Multi-Angle Projection Imaging of Biological Dynamics Fluorescent imaging of single nanoparticles and viruses on a smart phone Foldscope: origami-based paper microscope Quantitative imaging with a mobile phone microscope Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope Octopi: Open configurable high-throughput imaging platform for infectious disease diagnosis in the field Low-cost, sub-micron resolution, wide-field computational microscopy using opensource hardware OpenWSI: a low-cost, high-throughput whole slide imaging system via single-frame autofocusing and open-source hardware A versatile and customizable low-cost 3D-printed open standard for microscopic imaging PlanktonScope: Affordable modular imaging platform for citizen oceanography A one-piece 3D printed flexure translation stage for open-source microscopy Robotic microscopy for everyone: the OpenFlexure Microscope Whole-brain calcium imaging with cellular resolution in freely behaving Caenorhabditis elegans Pan-neuronal calcium imaging with cellular resolution in freely swimming zebrafish Rapid whole brain imaging of neural activity in freely behaving larval zebrafish Scale-free vertical tracking microscopy Wide-field, high-resolution Fourier ptychographic microscopy Computational illumination for high-speed in vitro Fourier ptychographic microscopy Quantitative differential phase contrast imaging in an LED array microscope 3D differential phase contrast microscopy Single-shot isotropic quantitative phase microscopy based on color-multiplexed differential phase contrast Physics-based learned design: Optimized coded-illumination for quantitative phase imaging High-speed in vitro intensity diffraction tomography High-resolution 3D refractive index microscopy of multiple-scattering samples from intensity images Computational structured illumination for high-content fluorescence and phase microscopy Fourier diffuserScope: single-shot 3D Fourier light field microscopy with a diffuser High-throughput, high-resolution interferometric light microscopy of biological nanoparticles Revealing architectural order with quantitative label-free imaging and deep learning uPTI: uniaxial permittivity tensor imaging of intrinsic density and anisotropy Single-cell cytometry via multiplexed fluorescence prediction by label-free reflectance microscopy Wide-field high-resolution 3d microscopy with fourier ptychographic diffraction tomography Deep learning extended depth-of-field microscope for fast and slide-free histology Open-source image reconstruction of super-resolution structured illumination microscopy data in ImageJ Deep learning enables fast and dense single-molecule localization with high accuracy DeepSTORM3D: dense 3D localization microscopy and PSF design by deep learning Accurate and rapid background estimation in single-molecule localization microscopy using the deep neural network BGnet Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations NanoJ: a high-performance open-source super-resolution microscopy toolbox Rapid image deconvolution and multiview fusion for optical microscopy Content-aware image restoration: pushing the limits of fluorescence microscopy Deep learning-based point-scanning super-resolution imaging Deep learning enables cross-modality super-resolution in fluorescence microscopy Virtual histological staining of unlabelled tissue-autofluorescence images via deep learning PhaseStain: the digital staining of label-free quantitative phase microscopy images using deep learning ZeroCostDL4Mic: an open platform to simplify access and use of Deep-Learning in Microscopy Cell Painting, a high-content image-based assay for morphological profiling using multiplexed fluorescent dyes CellProfiler 3.0: Next-generation image processing for biology CLIJ: GPU-accelerated image processing for everyone ImJoy: an open-source computational platform for the deep learning era Fast and accurate sCMOS noise correction for fluorescence microscopy Noise2void-learning denoising from single noisy images Probabilistic noise2void: Unsupervised content-aware denoising Fully unsupervised probabilistic noise2void DenoiSeg: Joint Denoising and Segmentation Improving Blind Spot Denoising for Microscopy DivNoising: Diversity Denoising with Fully Convolutional Variational Autoencoders Cell Detection with Star-Convex Polygons Star-convex Polyhedra for 3D Object Detection and Segmentation in Microscopy Cellpose: a generalist algorithm for cellular segmentation nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation DynaMorph: learning morphodynamic states of human cells with live imaging and sc-RNAseq Interpretable deep learning of label-free live cell images uncovers functional hallmarks of highly-metastatic melanoma Genuage: visualize and analyze multidimensional single-molecule point cloud data in virtual reality vLUME: 3D virtual reality for single-molecule localization microscopy u-track 3D: measuring and interrogating intracellular dynamics in three dimensions Expansion microscopy Protein-retention expansion microscopy of cells and tissues labeled using standard fluorescent proteins and antibodies In situ sequencing for RNA analysis in preserved tissue and cells Highly multiplexed subcellular RNA sequencing in situ Spatially resolved, highly multiplexed RNA profiling in single cells Spatial organization of the somatosensory cortex revealed by osmFISH Three-dimensional intact-tissue sequencing of single-cell transcriptional states Transcriptome-scale super-resolved imaging in tissues by RNA seqFISH+ 3D mapping and accelerated super-resolution imaging of the human genome using in situ sequencing Highly multiplexed imaging of single cells using a high-throughput cyclic immunofluorescence method Highly multiplexed immunofluorescence imaging of human tissues and tumors using t-CyCIF and conventional optical microscopes Deep profiling of mouse splenic architecture with CODEX multiplexed imaging Multiplexed and high-throughput neuronal fluorescence imaging with diffusible probes Immuno-SABER enables highly multiplexed and amplified protein imaging in tissues multiSero: Open multiplex-ELISA platform for analyzing antibody responses to SARS-CoV-2 infection The Flexiscope: a low cost, flexible, convertible and modular microscope with automated scanning and micromanipulation Design and implementation of 3D focus stabilization for fluorescence microscopy Super-resolution localization microscopy: Toward high throughput, high quality, and low cost Whole-cell, multicolor superresolution imaging using volumetric multifocus microscopy A simple and cost-effective setup for super-resolution localization microscopy Ultraprecise single-molecule localization microscopy enables in situ distance measurements in intact cells 3D active stabilization for single-molecule imaging Multicolor far-field fluorescence nanoscopy through isolated detection of distinct molecular species Multicolor fluorescence nanoscopy in fixed and living cells by exciting conventional fluorophores with a single wavelength Nanoscale subcellular architecture revealed by multicolor three-dimensional salvaged fluorescence imaging Spectral cross-cumulants for multicolor super-resolved SOFI imaging Fast multicolor 3D imaging using aberration-corrected multifocus microscopy Multifocus microscopy with precise color multi-phase diffractive optics applied in functional neuronal imaging High-contrast multifocus microscopy with a single camera and z-splitter prism Multiplane and spectrally-resolved single molecule localization microscopy with industrial grade CMOS cameras Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy Flexible multiplane structured illumination microscope with a four-camera detector Camera-Array 25-Plane Multifocus Microscope For Ultrafast Live 3d Imaging Three-dimensional beating dynamics of chlamydomonas flagella Note: Tormenta: An open source Python-powered control software for camera based optical microscopy calico/remote_refocus: Pre-print Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy-high performance super-resolution at low cost Quantitative comparison of camera technologies for cost-effective super-resolution optical fluctuation imaging (SOFI) Resolving the internal morphology of core-shell microgels with super-resolution fluorescence microscopy New polarized light microscope with precision universal compensator Birefringence changes of dendrites in mouse hippocampal slices revealed with polarizing microscopy Collection of food by Vorticella The form of beat in cilia of Stentor and Opalina FFDNet: Toward a fast and flexible solution for CNN-based image denoising Rapid focus map surveying for whole slide imaging with continuous sample motion Quasi-dome: A self-calibrated high-na led illuminator for fourier ptychography Efficient illumination angle self-calibration in Fourier ptychography High-power homogeneous illumination for super-resolution localization microscopy with large field-of-view Efficient homogeneous illumination and optical sectioning for quantitative single-molecule localization microscopy Highly inclined thin illumination enables clear single-molecule imaging in cells Wide-field fluorescence sectioning with hybrid speckle and uniform-illumination microscopy Optically sectioned in vivo imaging with speckle illumination HiLo microscopy Controlling organization and forces in active matter through optically defined boundaries Flexible structured illumination microscope with a programmable illumination array Fast widefield imaging of neuronal structure and function with optical sectioning in vivo fastSIM: a practical implementation of fast structured illumination microscopy DMD-based super-resolution structured illumination microscopy visualizes live cell dynamics at high speed and low cost Structured illumination microscopy using digital micro-mirror device and coherent light source Multicolor structured illumination microscopy and quantitative control of coherent light with a digital mirror device How to track bacteria Discriminative Correlation Filter Tracker with Channel and Spatial Reliability Scanned light sheet microscopy with confocal slit detection Advanced CLARITY for rapid and high-resolution imaging of intact tissues Concentrated dyes as a source of two-dimensional fluorescent field for characterization of a confocal microscope Super-resolution imaging of multiple cells by optimized flat-field epi-illumination Coordinated cellular neighborhoods orchestrate antitumoral immunity at the colorectal cancer invasive front 3-D PSF fitting for fluorescence microscopy: implementation and localization application Distractor-aware Siamese Networks for Visual Object Tracking 64 microsteps (with 8-microstepping), corresponding to nominal step size of 188 nm, 376 nm, 752 nm, 1.5 m, 3 m, 6 m, 12 m. (B-H) Zoomed-in view of (A). (I) Zoomed-in view of the "back-and-forth" maneuver (80 microsteps) to reduce the effect of mechanical backlash. (J-K) When the "back-and-forth" maneuver is not performed, unidirectional repeatability is worse and the first few steps are smaller. (L) The step size is relatively uniform when the stage is actuated by the piezo stack, suggesting that the mechanical backlash is in the linear actuator rather than the ball bearing stage. (M) Scanning with the linear actuator at 5 Hz with peak-to-peak amplitude of 180 m (N) Scanning with the piezo stack at 30 Hz with peak We thank all members of Prakash Lab for feedback throughout this work. We thank John Hickey, David McIlwain and Christian Schuerch for providing CODEX samples and helpful discussions. We thank Xiao Wang for providing the STARMap sample. We thank Chunzi Liu for providing the human conjunctival epithelial cell culture. We thank Windell H. Oskay (Evil Mad Scientist Lab) for providing CNC machining suggestions. We thank QDLaser for letting us evaluate their frequency doubled quantum dot laser module. We thank early Squid platform adopters, including Mireille Kamariza, Christina Hueschen, Eva de la Serna, Kiara s exposure time) before and after FFDNet denoising. FFDNet denoising effectively reduced noise and at the same time preserved details. We found the same denoising also worked well with images from fluorescence microscopy using color CMOS sensors [44] .